Revised contraindications for the use of non-medical WB-electromyostimulation. Evidence-based German consensus recommendations
- 1Institute of Radiology, University Hospital Erlangen, Erlangen, Germany
- 2Department of Sports Science, Rheinland-Pfälzische Technische Universität Kaiserslautern-Landau, Kaiserslautern, Germany
- 3German University for Prevention and Health Management, Saarbrücken, Germany
- 4Institute of Training Science and Sport Informatics, German Sport University Cologne, Cologne, Germany
- 5Musculoskeletal University Center, Ludwig-Maximilian-University of Munich, Munich, Germany
- 6Hessian College of Police and Administration, Wiesbaden, Germany
- 7Department of Rehabilitation Sciences, Faculty of Health, University of Witten/Herdecke, Witten, Germany
- 8Soccer Club Paderborn 07, Paderborn, Germany
- 9Glucker Kolleg, Frankfurt, Germany
- 10Bundeswehr Medical Academy Munich, Munich, Germany
- 11PT Lounge Cologne, Cologne, Germany
- 12EMS-Performance, Kornwestheim, Germany
- 13Department of Medical and Life Sciences, University of Furtwangen, Schwenningen, Germany
A Commentary on
By Reljic D, Herrmann HJ and Zopf Y (2024). Front Sports Act Living. 6:1425233. doi: 10.3389/fspor.2024.1425233
Introduction
There is an ongoing discussion on safety aspects related to the commercial whole-body electromyostimulation (WB-EMS) market. Apart from mandatory federal regulation, the most controversial area may well be the relative and absolute contraindications for WB-EMS application. In a recent commentary, Reljic et al. (1) addressed the “revised contraindications for the use of non-medical WB-Electromyostimulation adopted as an evidence based consensus recommendation by a broad consortium of German researchers (2). In summary, Reljic et al. (1) criticize in particular the current status of tumor and cancer still being classified as a relative contraindication for commercial, non-medical WB-EMS application. Considering the outstanding experience of this research group in the evaluation of WB-EMS application in cancer patients (3), we take their objection very seriously and would like to explain our decision in more detail.
First of all, we feel that due to our strict evidence- and consensus-based approach, some basic aspects might have not pointed out clearly enough. In line with Reljic et al, we fully agree that WB-EMS is a very safe exercise technology when properly applied (3, 4). So far, apart from a few trials that provoke rhabdomyolysis by excessive impulse intensity in novice applicants [e.g., (5, 6)], no clinical trial has reported acute or chronic “suspected unexpected serious adverse reaction” (SUSARs) during or after WB-EMS application (3, 4, 7). However, the safety standards of clinical studies with their trial physicians, study nurses, experienced trainers and scientific monitoring boards vary considerably from the real world setting of commercial, non-medical suppliers. As a matter of fact, the present strategy of commercial facilities of training up to 200 widely different clients per week in parallel on two WB-EMS devices supervised by one instructor cannot but conflict with the need to consistently handle vulnerable cohorts with adequate care und expertise. Thus, we are convinced that our contraindications that focus exclusively on commercial non-medical WB-EMS settings protect not only vulnerable clients but also over motivated trainers and owners of WB-EMS facilities from themselves. To stress the above aspect again, people with conditions contraindicated to WB-EMS application in commercial, non-medical facilities were not excluded from each and every WB-EMS application. On the contrary, medical WB-EMS facilities (8)1 with their enhanced medical expertise and closer supervision are perfectly suited for applying this safe and efficient exercise technology in vulnerable cohorts. This approach of well-controlled medical settings is fully in line with the demand of Reljic et al. for appropriate medical settings for tumor patients.
Another source of misunderstanding might be our interpretation of absolute and relative contraindications. In general, contraindications predominately emphasize the balance between risks and benefits of a treatment or procedure. An absolute contraindication was considered as an event or substance that could cause a life-threatening situation. Correspondingly, a procedure or medicine that falls under this category must be avoided (9). However, particularly the risk of physical exercise including WB-EMS in vulnerable people depends greatly on the framework of its application. In a closely supervised and experienced medical WB-EMS setting, the risk of adverse effects or even life-threatening situations is much less pronounced for vulnerable cohorts compared to commercial, non-medical settings. This aspect leads to diverging results of risk/benefit assessments in medical vs. non-medical WB-EMS facilities, and ultimately to the outcome that the absolute contraindications for commercial non-medical facilities listed in the “revised contraindications” (2) are not necessarily applicable for medical WB-EMS institutions. Considering further that even relative contraindications still need a medical risk/benefit assessment prior to approval, we feel that the switch of tumor and cancer from an absolute to a relative contraindication for commercial non-medical WB-EMS application is a reasonable and responsible step to easily enable the application of WB-EMS in stable tumor patients, for example. In contrast to the demand of Reljic et al. (1), however, this means that after medical approval, eligible tumor patients are enabled to exercise in non-medical facilities.
With reference to the recommendation of Reljic et al. (1) to base relative contraindication for tumor and cancer on the more specific oncologic exercise guideline, we have also considered this dedicated and precise approach in the consensus conferences. Nevertheless, since exercise guidelines are also available for other diseases (e.g., diabetes mellitus) covered in this publication on WB-EMS contraindications (10, 11), listing all condition-specific contraindications would not be compatible with a guideline that is still easy to apply. However, the aspect that potential relative contraindications have to be verified by the attending physician aware of the limitation of their patient will ensure the application of dedicated-condition specific recommendations.
Another critical aspect related to the proper application of contraindications is the role of the medical gate keeper (especially physicians) and the availability of medical WB-EMS. Despite the large popularity and widespread distribution of WB-EMS in Germany, the necessary WB-EMS expertise of the medical decision-maker cannot be universally assumed, which might lead to unnecessary decisions against WB-EMS application. Further, the presently decelerated dissemination of medical WB-EMS prevents reaching vulnerable cohorts that could particularly benefit from WB-EMS. This development is due not least to the limited prescribability of WB-EMS by the healthcare system.
Finally one should keep in mind the non-mandatory character of our “revised contraindications for WB-EMS application”. But having said that, in the light of bans (12), critical public media releases (13) and serious federal regulations (14, 15), the safety aspects on WB-EMS should be given maximum priority in order to prevent further restrictions. One may consider the particular negative focus on WB-EMS compared to conventional types of exercise as unfair. Nevertheless, it should be noted that the simultaneous stimulation of (all) large muscle areas, the possibility of applying supramaximal stimulus intensity and especially the aspect that protective physiological mechanisms of muscle fatigue and overload (16) do not apply to NEMS techniques and so constitute an enhanced risk potential. Correspondingly a close attention with safety aspects to WB-EMS application is well advised.
Author contributions
WK: Conceptualization, Funding acquisition, Methodology, Project administration, Supervision, Writing – original draft, Writing – review & editing. MF: Validation, Writing – original draft, Writing – review & editing. OL: Writing – original draft, Writing – review & editing, Validation. CE: Writing – original draft, Writing – review & editing, Validation. JB: Conceptualization, Writing – original draft, Writing – review & editing, Validation. FMi: Writing – original draft, Writing – review & editing. HK: Writing – original draft, Writing – review & editing. BW: Writing – original draft, Writing – review & editing. CZ: Writing – original draft, Writing – review & editing. FMo: Writing – original draft, Writing – review & editing, Validation. MT: Conceptualization, Writing – original draft, Writing – review & editing, Validation. AF: Writing – original draft, Writing – review & editing, Validation. SM: Writing – original draft, Writing – review & editing, Validation. KE: Writing – original draft, Writing – review & editing, Validation. JV: Writing – original draft, Writing – review & editing, Validation. SA: Writing – original draft, Writing – review & editing, Validation. MK: Investigation, Writing – original draft, Writing – review & editing. SS: Investigation, Project administration, Writing – original draft, Writing – review & editing, Resources, Validation.
Funding
The author(s) declare that no financial support was received for the research, authorship, and/or publication of this article.
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
The author(s) declared that they were an editorial board member of Frontiers, at the time of submission. This had no impact on the peer review process and the final decision.
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
Footnote
1. ^Medical WB-EMS is defined as a (1) primarily therapeutic intervention (2) based on an existing diagnosis (3) that is provided by qualified medical–therapeutic personnel (4) in compliance with current guidelines and (5) using medical devices (8).
References
1. Reljic D, Herrmann HJ, Zopf Y. Commentary: revised contraindications for the use of non-medical WB-electromyostimulation. Evidence-based German consensus recommendations. Front Sports Act Living. (2024) 6:1425233. doi: 10.3389/fspor.2024.1425233
2. von Stengel S, Frohlich M, Ludwig O, Eifler C, Berger J, Kleinoder H, et al. Revised contraindications for the use of non-medical WB-electromyostimulation. Evidence-based German consensus recommendations. Front Sports Act Living. (2024) 6:1371723. doi: 10.3389/fspor.2024.1371723
3. Beier M, Schoene D, Kohl M, von Stengel S, Uder M, Kemmler W. Non-athletic cohorts enrolled in longitudinal whole-body electromyostimulation trials—an evidence map. Sensors (Basel). (2024) 24:972. doi: 10.3390/s24030972
4. Kemmler W, von Stengel S, Uder M. Safety and attractiveness of whole-body electromyostimulation in non-athletic cohorts. A scoping review. Preprints. (2024) 2024061540. doi: 10.20944/preprints202406.1540.v1
5. Hettchen M, Glockler K, von Stengel S, Piechele A, Lotzerich H, Kohl M, et al. Effects of compression tights on recovery parameters after exercise induced muscle damage: a randomized controlled crossover study. Evid Based Complement Alternat Med. (2019) 2019:5698460. doi: 10.1155/2019/5698460
6. Teschler M, Weissenfels A, Bebenek M, Frohlich M, Kohl M, von Stengel S, et al. Very high creatine kinase CK levels after WB_EMS. Are there implications for health. Int J Clin Exp Med. (2016) 9:22841–50. doi: 10.1007/s10354-015-0394-1
7. Le YE, Schoene D, Kohl M, von Stengel S, Uder M, Kemmler W. Outcomes addressed by longitudinal whole-body electromyostimulation trials in middle aged-older adults—an evidence map. Japan J Med Sci. (2024) 2:2024030183. doi: 10.20944/preprints202403.0183.v1
8. Berger J, Fröhlich M, Kemmler W. WB-EMS Market development—perspectives and threats. Int J Environ Res Public Health. (2022) 19:14211. doi: 10.3390/ijerph192114211
9. National_Library_of_Medicine. Contraindication. MedlinePlus. Medical Encyclopedia. Access date: 28.07.2024. (2024).
10. Colberg SR, Sigal RJ, Yardley JE, Riddell MC, Dunstan DW, Dempsey PC, et al. Physical activity/exercise and diabetes: a position statement of the American diabetes association. Diabetes Care. (2016) 39:2065–79. doi: 10.2337/dc16-1728
11. Esefeld K, Kress S, Behrens M, Zimmer P, Stumvoll M, Thurm U, et al. Diabetes, sports and exercise. Exp Clin Endocrinol Diabetes. (2023) 131:51–60. doi: 10.1055/a-1946-3768
12. Malnick SD, Band Y, Alin P, Maffiuletti NA. It’s time to regulate the use of whole body electrical stimulation. Br Med J. (2016) 352:i1693. doi: 10.1136/bmj.i1693
14. BMU. Verordnung zum Schutz vor schädlichen Wirkungen nichtionisierender Strahlung bei der Anwendung am Menschen (NiSV) (Vol. Teil I Nr. 41). Bonn: Bundesanzeiger Verlag (2019).
15. BMU. Anforderungen an den Erwerb der Fachkunde für Anwendungen nichtionisierender Strahlungsquellen am Menschen. Bonn: Bundesanzeiger Verlag (2020).
Keywords: whole-body electromyostimulation, contraindications, safety, exercise, oncology, tumor, cancer
Citation: Kemmler W, Fröhlich M, Ludwig O, Eifler C, Berger J, Micke F, Kleinöder H, Wegener B, Zinner C, Mooren FC, Teschler M, Filipovic A, Müller S, England K, Vatter J, Authenrieth S, Kohl M and von Stengel S (2024) Response: Commentary: Revised contraindications for the use of non-medical WB-electromyostimulation. Evidence-based German consensus recommendations”. Front. Sports Act. Living 6:1473103. doi: 10.3389/fspor.2024.1473103
Received: 31 July 2024; Accepted: 25 September 2024;
Published: 21 October 2024.
Edited by:
Alessandra Di Cagno, Università degli Studi di Roma Foro Italico, ItalyReviewed by:
Enzo Iuliano, eCampus University, ItalyFabrizio Perroni, University of Urbino Carlo Bo, Italy
Copyright: © 2024 Kemmler, Fröhlich, Ludwig, Eifler, Berger, Micke, Kleinöder, Wegener, Zinner, Mooren, Teschler, Filipovic, Müller, England, Vatter, Authenrieth, Kohl and von Stengel. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: W. Kemmler, wolfgang.kemmler@fau.de
†ORCID:
W. Kemmler
orcid.org/0000-0003-3515-0669