Skip to main content

ORIGINAL RESEARCH article

Front. Nutr.
Sec. Food Chemistry
Volume 11 - 2024 | doi: 10.3389/fnut.2024.1439287
This article is part of the Research Topic Novel Technologies Applied to Flavoromics and Sensory Evaluation of Foods View all 7 articles

Development of an ic-CLEIA for precise detection of 3-CQA in herbs and patent medicines: ensuring quality control and therapeutic efficacy

Provisionally accepted
  • Shaanxi University of Technology, Hanzhong, Shaanxi, China

The final, formatted version of the article will be published soon.

    Background: 3-caffeoylquinic acid (3-CQA), a member of the chlorogenic acid family, possesses diverse pharmacological properties, such as scavenging, antioxidant, and antiapoptotic activity, rendering substantial value to alimentary consumables and therapeutic substances. However, the pervasiveness of non-standard practices, notably the misuse and abuse of indigenous botanicals, coupled with the inherent susceptibility of 3-CQA to degradation under light and heat exposure, engenders discernible disparateness in the quality profiles of the same kinds of herbs. Consequently, precise quantification of 3-CQA becomes imperative.In this context, an artificial antigen was synthesized as a specific conjugate of 3-CQA and bovine serum albumin (3-CQA-BSA), followed by the generation of a monoclonal antibody (mAb) against the conjugate. Through optimization, a mAb-based indirect competitive chemiluminescence enzyme immunoassay (ic-CLEIA) was developed.Results: It demonstrated an IC50 and the calibration range of 2.97 ng/mL and 0.64-13.75 ng/mL, respectively, outperforming the conventional enzyme-linked immunosorbent assay (ELISA). Notably, the ic-CLEIA displayed 10.71% cross-reactivity with 3,5-dicaffeoylquinic acid, alongside minimal cross-reactivity towards other isomeric counterparts and analogs. Validation experiments on herbs and Chinese patent medicines using ic-CLEIA, confirmed by high-performance liquid chromatography (HPLC) analysis, revealed a robust correlation coefficient of 0.9667 between the two modalities.These findings unequivocally demonstrated that the proposed ic-CLEIA represents a viable and reliable analytical method for 3-CQA determination. This method holds significant potential for ensuring the quality control and therapeutic efficacy germane to herbs and patent medicines, spanning diverse therapeutic milieus and applications.

    Keywords: 3-caffeoylquinic acid (3-CQA), Indirect competitive chemiluminescence enzyme immunoassay (ic-CLEIA), Monoclonal antibody (mAb), Enzyme-linked immunosorbent assay (ELISA), Quality control

    Received: 27 May 2024; Accepted: 09 Aug 2024.

    Copyright: © 2024 Wu, Dang, Wu, Isah and Zhang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

    * Correspondence: Xiaoying Zhang, Shaanxi University of Technology, Hanzhong, Shaanxi, China

    Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.