Skip to main content

ORIGINAL RESEARCH article

Front. Immunol., 17 July 2024
Sec. Inflammation

Integrating Pt nanoparticles with 3D Cu2-xSe/GO nanostructure to achieve nir-enhanced peroxidizing Nano-enzymes for dynamic monitoring the level of H2O2 during the inflammation

Man Shen&#x;Man Shen1†Xianling Dai&#x;Xianling Dai1†Dongni NingDongni Ning2Hanqing XuHanqing Xu1Yang ZhouYang Zhou1Gangan ChenGangan Chen1Zhangyin RenZhangyin Ren1Ming Chen,,*Ming Chen1,2,3*Mingxuan Gao*Mingxuan Gao1*Jing Bao*Jing Bao1*
  • 1Department of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China
  • 2College of Pharmacy and Laboratory Medicine, Third Military Medical University (Army Medical University), Chongqing, China
  • 3State Key Laboratory of Trauma, Burn and Combined Injury, Army Medical University, Chongqing, China

The treatment of wound inflammation is intricately linked to the concentration of reactive oxygen species (ROS) in the wound microenvironment. Among these ROS, H2O2 serves as a critical signaling molecule and second messenger, necessitating the urgent need for its rapid real-time quantitative detection, as well as effective clearance, in the pursuit of effective wound inflammation treatment. Here, we exploited a sophisticated 3D Cu2-xSe/GO nanostructure-based nanonzymatic H2O2 electrochemical sensor, which is further decorated with evenly distributed Pt nanoparticles (Pt NPs) through electrodeposition. The obtained Cu2-xSe/GO@Pt/SPCE sensing electrode possesses a remarkable increase in specific surface derived from the three-dimensional surface constructed by GO nanosheets. Moreover, the localized surface plasma effect of the Cu2-xSe nanospheres enhances the separation of photogenerated electron-hole pairs between the interface of the Cu2-xSe NPs and the Pt NPs. This innovation enables near-infrared light-enhanced catalysis, significantly reducing the detection limit of the Cu2-xSe/GO@Pt/SPCE sensing electrode for H2O2 (from 1.45 μM to 0.53μM) under NIR light. Furthermore, this biosensor electrode enables in-situ real-time monitoring of H2O2 released by cells. The NIR-enhanced Cu2-xSe/GO@Pt/SPCE sensing electrode provide a simple-yet-effective method to achieve a detection of ROS (H2O2、-OH) with high sensitivity and efficiency. This innovation promises to revolutionize the field of wound inflammation treatment by providing clinicians with a powerful tool for accurate and rapid assessment of ROS levels, ultimately leading to improved patient outcomes.

Introduction

Reactive oxygen species (ROS) play a vital role in wound inflammation treatment (1). Their reactive and destructive properties enable neutrophils and macrophages to phagocytose, thus aiding in inflammation management (24). Hydrogen peroxide (H2O2) is a major secondary messenger in the treatment of inflammation and a typical ROS molecule in biomedical diagnostics (5, 6). Over the past few years, the preponderance of evidence has established that H2O2 has a particularly significant impact on the stress/inflammatory response and subsequent tissue/neuronal repair processes (79). The inherent characteristics of H2O2 such as its ease of degradation, long half-life, universal present in all cells, and membrane/tissue permeability - dictate its functional role. Within a certain concentration range, H2O2 performs multiple functions: (1) it stimulates proliferation of human fibroblasts and vascular endothelial cells; (2) it boosts macrophage inflammatory protein (MIP)-1α production; and (3) it promotes angiogenesis via vascular endothelial growth factor (VEGF) signaling and catalytic effects on keratin-forming cells (2, 10). However, at elevated concentrations, H2O2 can lead to cell necrosis by triggering pro-apoptotic proteins and ultimately causing cell death. It is evident that the physiological effects of H2O2 are usually concentration-dependent; hence, there is a pressing need to explore effective methods for accurately detecting H2O2 concentration in living cells (11).

Sensing technologies such as fluorescence (12), chemiluminescence (13), colorimetry (14), photoelectrochemical sensing (15) and electrochemical sensing (16) have been developed for the detection of H2O2. Recently, electrochemical sensing technology, which offers the advantages of simple operation, fast response, high sensitivity, and high selectivity has been receiving immense research attention for real-time H2O2 detection. To address the limitations of expensive and environmentally unstable catalase to the widespread application of sensors, there has been a growing interest in the study of biomimetic electrochemical H2O2 sensors that possess peroxidase-like activity without the need for enzymes (17, 18).

The advancement of efficient nano-enzymatic materials is paramount for expeditious in situ detection of H2O2 (19). These materials, which range from noble metal nanoparticles like Au (20), Pt (21), Ag (22), etc., to metal oxides or compounds nanostructures such as CeO2 (23), TiO2 (24), MnO2 (25), etc., exhibit exceptional hydrogen peroxidase activity. This activity not only effectively mitigates excess H2O2 in the physiological environments, but also signifies their vast potential in applications like wound healing and inflammation therapy. Specifically, Pt NPs demonstrate promising applications in H2O2 electrochemical sensors due to their excellent peroxidase-like activity (26, 27). However, ensuring the uniform anchoring of these metal nanoparticles on smooth electrodes remains a significant challenge for electrochemical detection of H2O2. Fortunately, numerous studies have established that carbon-based materials can be used as support structures for growing and anchoring metal particles, thereby preventing their aggregation (28). Carbon nanosubstrates such as carbon nanotubes (29), graphene (30) and carbon fibers (31) can even facilitate the spontaneous generation of metal nanoparticles on the substrate, eliminating the need for additional reducing agents. As an example, Tong et al (32). reported a self-terminating chemical deposition method to prepare surfactant-free monodisperse Pt nanoparticle (NP)-modified carbon fiber microelectrodes (Pt-NP/CFE) for electrochemical detection of hydrogen peroxide (H2O2) released by living cells. This method represents a significant breakthrough in the field of nano-enzymatic materials development, paving the way for more effective and precise in situ detection of H2O2. However, the enhancement of stability and catalytic activity of metal nanoparticles remains a formidable challenge for their implementation in the expeditious and precise detection of trace amounts of H2O2. To achieve rapid detection of minute amounts of H2O2, extensive research has been conducted on the development of composite nanoenzymes. Innovative researchers have devised various copper-based nanomaterials, including CuO (33), Cu-MOF (34), and CuS (35), and evaluated their efficacy in enzyme-like catalysis. Copper-based nanomaterials hold high research value for their application in H2O2 detection. Furthermore, copper-based nanomaterials exhibit unique optical properties. In particular, copper selenide nanocrystals (Cu2-xSe), as a p-type semiconductor nanomaterial, generate a profusion of photogenerated electron-hole pairs under irradiation of near-infrared light by localized surface plasmon resonance (LSPR) in response to oscillating electromagnetic field interactions of light (36). Moreover, the semiconductor-metal heterojunction formed by the union of copper selenide and metal nanoparticles abbreviates the band gap of the material, thereby augmenting its catalytic activity.

Herein, we have developed sensing electrodes, made from Cu2-xSe/GO@Pt composites, for rapid and precise in situ detection of H2O2 (Scheme 1). Initially, we employed our previously established method (37) to generate Cu2-xSe nanospheres containing copper defects. Subsequently, we integrated GO nanosheets as a substrate, ensuring the nanospheres were firmly anchored to the electrodes and facilitating the electrodeposition of Pt nanoparticles. Meanwhile, the three-dimensional structure of the GO nanosheets on the electrode surface not only provides a larger specific surface area, but also offers more efficient electron and ion transport paths, ultimately enhancing the catalytic performance of the sensing electrode. In addition, the unique photoelectric effect of Cu2-xSe nanorods also plays a crucial role in the enhancement of the sensing electrode’s ability to detect H2O2. Therefore, the prepared Cu2-xSe/GO@Pt sensing electrode demonstrates superior electrocatalytic activity towards H2O2, making it an ideal candidate real-time detection of H2O2 released from living cells.

Scheme 1
www.frontiersin.org

Scheme 1 Schematic illustration of the formation of Cu2-xSe/GO@Pt/SPCE electrochemical sensors and its principle for H2O2 detection.

Experimental section

Reagents and solutions

Polystyrene sulfonic acid (PSS, MW 70 kda), pelenium dioxide (SeO2) and Copper sulfate pentahydrate (CuSO4·5H2O) were all purchased from Aladdin Reagent Co., Ltd. (Shanghai,China). Ascorbic acid (AA), chloroplatinic acid hexahydrate (H2PtCl6·6H2O), glycine (Gly), citric acid (CA), urea, and glutathione (GSH) were obtained from Sigma-Aldrich (St. Louis, USA). Potassium chloride (KCl), potassium ferricyanide (K3[Fe(CN)6]), potassium hexacyanoferrate(II) (K3[Fe(CN)6]) and H2O2 were obtained from Chuandong Chemical Co., Ltd. (Chongqing, China). Phosphate buffered saline (PBS) was purchased from BioInd (Gibco). All chemicals and reagents were used as received without any further purification. All solutions were prepared using ultrapure water (18.2 MΩ). Graphene oxide (GO) powder and Mxene powder were both obtained from Sigma-Aldrich (St. Louis, USA).

Synthesis of Cu2-xSe NPs

Cu2-xSe NPs were prepared by the previously reported situ reduction method. Briefly, 1.6 mL PSS (10 mg mL-1) and 5.5 mL DI water were added into a round-bottom flask which stirred in a 30°C water bath, then 0.3 mL Vc (0.4 M) and 0.1 mL SeO2 (0.2 M) were added in sequence, stirring at 30°C for 20 min. A mixed solution of 0.1 mL CuSO4·5H2O (0.4 M) and 0.4 mL Vc (0.4 M) were added in the next step. Then, the mixed solution was strongly stirred at 45°C for 8h to obtain a dark green dispersion, centrifuged at 12000 rpm for 5 min, and suspended in DI water to obtain Cu2-xSe solution. Next, the Cu2-xSe solution freeze dried in vacuum environment, and it was redispersed in DI water (1 mg mL-1) at 4°C for later use.

Fabrication of the Cu2-xSe/GO@Pt/SPCE Sensing Electrodes

Firstly, several screen-printed carbon electrodes (SPCE) were prepared, washed with DI water and then dried for use. In a general way, 10 μL Cu2-xSe NPs (1 mg mL-1), 2.5 μL GO (1 mg mL-1), and 7.5 μL DI water were uniformly mixed together, and then 10 μL of the mixture (Cu2-xSe/GO) was dropped on a bare SPCE, followed by drying at 37°C. After that, Pt NPs were electrodeposited on Cu2-xSe/GO/SPCE in 5 mL mixture of 1 mM H2PtCl6 solution to obtain Cu2-xSe/GO@Pt/SPCE. For comparison, the same method was used to prepare Cu2-xSe/Mxene@Pt/SPCE, Cu2-xSe @Pt/SPCE, and prepared Cu2-xSe/SPCE without electrodeposition.

Characterization of Cu2-xSe/GO@Pt/SPCE sensing electrodes

Scanning electron microscopy (SEM) was used to analyze the surface morphology of Cu2-xSe/GO@Pt/SPCE and the surface distribution of Pt nanoparticles. X-ray photoelectron spectroscopy (XPS) was used to analyze the chemical states of elements on the surface of the prepared sensor electrodes.

Electrochemical measurements

All the electrochemical tests were performed using the CHI760E electrochemical workstation. The electrodeposition process is carried out for 200 s at a potential of −0.2 V using chronocurrent method (i-t). In order to characterize the electrochemical behavior of Cu2-xSe/GO@Pt/SPCE, CV and EIS were recorded in a 5 mM [Fe (CN)6]3−/4− solution containing 0.1 M KCl. When the electrocatalytic performance of H2O2 was tested by Cu2-xSe/GO@Pt/SPCE, CV and i-t were monitored at 0.1 M PBS (pH = 7.4). The test parameters of CV: the operating voltage range is -0.8~ 0.8 V, and the scanning rate is 20-300 mV s-1. The linear response of the detection electrode to H2O2 in the i-t test was performed at an optimal operating voltage of -0.4 V.

Electrochemical detection of H2O2 released from cells

The L929 cells (Shanghai Yihe Biotechnology Co., Ltd) were cultured in 5% CO2 in 75 cm2 culture flask containing MEM medium, 1% penicillin and streptomycin and 10% (v/v) horse serum at 37 °C. Unlike L929 cells, RAW264.7 (Shanghai Yihe Biotechnology Co., Ltd) cells need to be cultured in 75 cm2 culture flasks containing DMEM medium, 10% FBS and 1% double antibody at 37 °C and 5% CO2Wash 2 times in PBS (0.01 M, pH=7.4), digest the cells, and centrifuge at 1000 rpm for 3min. Resuspend the cells and counted the cells by calculating instrument. When the current keeps stable, gently stir the cell suspension. Then, the N-Formyl-Met-Leu-Phe (fMLP, Sigma) was added to the cell suspension with different concentration, which can motivate cells generation of H2O2 and have no interference to the detection of H2O2. The amperometric current response of H2O2 in about 7*107 L929 cells or 8*107 RAW 264.7 cells in 10 mL of PBS with the bare SPCE and Cu2-xSe/GO@Pt/SPCE, and the electrode was recorded at -0.4 V.

Results and discussion

Characterization of the As-prepared Cu2-xSe/GO@Pt/SPCE sensing electrode

The morphology and structure of the materials and electrodes were characterized by transmission electron microscopy (TEM) and scanning electron microscopy (SEM). As shown in Supplementary Figure S1, TEM images of Cu2-xSe nanospheres proved that they had a uniform spherical morphology with a diameter of about 40 nm and a smooth surface. The SEM images of the bare screen-printed carbon electrodes (SPCE) electrode exhibited that the electrode possesses a rough and porous micro-morphology, which is favorable for modifying the nano-electrode materials (Supplementary Figures S2A, B). However, as shown in Supplementary Figure S2C, when only Cu2-xSe NPs were modified on the SPCE, the electrode surface was not completely covered by the nanospheres. In contrast, when the Cu2-xSe/GO mixture was added dropwise to the electrode, the Cu2-xSe NPs were evenly distributed across the graphene oxide nanosheets, and the complex completely covered the SPCE surface (Supplementary Figure S2E). The incorporation of GO nanosheets provided a reliable three-dimensional (3D) framework for Cu2-xSe NPs and contributed to their anchoring to the electrodes. SEM images of Cu2-xSe/GO@Pt/SPCE obtained after modifying Pt nanoparticles (Pt NPs) on Cu2-xSe/GO/SPCE by electrodeposition were depicted in Figures 1A–C. The image results showed that the electrode modified with Pt NPs still presented a 3D porous shape, indicating that the modification of Pt NPs didn’t affect the morphology and structure of GO and Cu2-xSe NPs. The 3D porous structure formed by GO nanosheets and Cu2-xSe NPs as a substrate for the electrodeposition of Pt NPs reduced the aggregation of nanoparticles, promoted a robust anchoring of nanoparticles, and provided a reducing agent for the reduction of monomeric Pt. Furthermore, the EDS elemental mapping was carried out to observe the elemental compositions of Cu2-xSe/GO@Pt/SPCE electrode, in which the Pt signal confirmed the successful loading of the Pt NPs in the Cu2-xSe/GO structure (Figure 1D).

Figure 1
www.frontiersin.org

Figure 1 (A–C) SEM images of Cu2-xSe/GO@Pt/SPCE; (D) the corresponding elemental mapping images of Cu2-xSe/GO@Pt/SPCE.

In order to study the elemental chemical composition and valence states of Cu2-xSe/GO@Pt/SPCE, we characterized the electrode using by X-ray photoelectron spectroscopy (XPS). The XPS spectra revealed the presence of C, Cu, Se, and Pt elements in the Cu2-xSe/GO@Pt/SPCE (Supplementary Figure S3A). The spectra of the Cu 2p orbital indicated the coexistence of both Cu2+ and Cu+ in Cu2-xSe NPs (Figure 2A) and Cu2-xSe/GO@Pt/SPCE (Figure 2B). Meanwhile, the proportion of Cu2+ increased from 23.88% to 31.73% after the deposition of Pt NPs, consistent with the Cu+ oxidation process. Compared to Cu2-xSe NPs, there were obvious negative shifts for the Cu2+ and Cu+ binding energies of Cu2-xSe/GO@Pt/SPCE, indicating a strong interaction between Pt NPs and Cu2-xSe NPs. The high-resolution XPS spectrum of Cu2-xSe/GO@Pt/SPCE showed peaks of C1s at 284.05, 284.50, and 285.0 eV corresponding to C=C/C-C, C-O, and C=O bonds (Figure 2C) (38). Moreover, the Se 3d XPS spectrum of the Cu2-xSe NPs and Cu2-xSe/GO@Pt/SPCE exhibited two main peaks (Se 3d5/2 and Se 3d3/2), indicating that that the valence state of Se element was not affected by the electrodeposition process of Pt NPs (Supplementary Figures S3B, C). Additionally, Pt0 peaks were observed at the binding energies of 74.4 eV and 71.01 eV, with a Pt0 ratio of 72.95% (Figure 2D), confirming the successful deposition of Pt NPs. Based on the above analysis, we have successfully prepared a Cu2-xSe/GO@Pt/SPCE sensing electrode with a unique 3D porous structure, providing a faster conductive network for the electrochemical detection of H2O2. This advancement paves the way for future applications in sensing technologies.

Figure 2
www.frontiersin.org

Figure 2 (A) The high-resolution XPS spectra for Cu 2p of Cu2-xSe NPs. The high-resolution XPS spectra for (B) Cu 2p, (C) C 1s, (D) Pt 4f of Cu2-xSe/GO@Pt/SPCE.

Electrochemical characterization of Cu2-xSe/GO@Pt/SPCE sensing electrode

To evaluate the electrochemical performance of SPCE, Cu2-xSe/SPCE, Cu2-xSe@Pt/SPCE, Cu2-xSe/Mxene@Pt/SPCE and Cu2-xSe/GO@Pt/SPCE, typical cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) has been applied to thoroughly characterize the electrodes (Figure 3A; Supplementary Figure S4). As shown in Figure 3A, a pair of Fe2+/3+ redox peaks could be observed on the CV curves of all electrodes in the range of 0-0.2 V. However, the redox peaks of all electrodes except the bare SPCE exhibited wider peak potential differences and lower peak currents. Apparently, these electrodes also exhibited a pair of Cu2+/Cu+ redox peaks in the range of 0.4-0.6 V, which influenced the peak width and peak current of Fe2+/3+ redox peak. Among them, Cu2-xSe/GO@Pt/SPCE exhibited the highest peak current in the range of 0.4-0.6 V, highlighting its excellent electrochemical performance. Additionally, Supplementary Figure S4 displays the EIS curves of all the aforementioned electrodes. The EIS curves of the Cu2-xSe/GO@Pt/SPCE in the line part representing Warburg impedance (Rw) exhibited the steepest slope, indicating that electrolyte ions had the smallest diffusion resistance in the pores of the electrode, thereby facilitating electrochemical reactions. These findings highlight the significance of material design and engineering in enhancing electrochemical performance.

Figure 3
www.frontiersin.org

Figure 3 (A) CVs of bare SPCE, Cu2-xSe/SPCE, Cu2-xSe@Pt/SPCE, Cu2-xSe/Mxene@Pt/SPCE and Cu2-xSe/GO@Pt/SPCE in 5 mM [Fe (CN)6]3-/4- containing 0.1 M KCl solution at scan rate of 50 mV s-1; (B) CV curves of Cu2-xSe/SPCE, Cu2-xSe@Pt/SPCE, Cu2-xSe/Mxene@Pt/SPCE and Cu2-xSe/GO@Pt/SPCE with 5 mM H2O2 in 0.01 M PBS at 50 mV s-1; (C) and the i-t curves of the successive additions of H2O2 with 9 times; (D) CV curves of Cu2-xSe/GO@Pt/SPCE electrode in 0.01 M PBS in the presence of 0~5 mM H2O2; (E) CV curves of Cu2-xSe/GO@Pt/SPCE with 5 mM H2O2 in 0.01 M PBS at different scan rates. Scan rate in the range of 20~300 mV s-1; (F) Linear relationship between the peak current and scan rates.

Furthermore, the electrocatalysis of H2O2 by the prepared electrodes mentioned above was investigated in 10 mL 0.01 M PBS (pH 7.4) system using both CV and i-t methods. The CV curves of each electrode in PBS buffer containing 5 mM H2O2, as displayed in Figure 3B, clearly indicate that the Cu2-xSe/SPCE without electrodeposition of Pt NPs exhibited no distinct characteristic peak of current response. In contrast, the other three electrodes showed well-defined reduction peaks at -0.32 V (Cu2-xSe@Pt/SPCE), -0.3 V (Cu2-xSe/Mxene@Pt/SPCE), and -0.4 V (Cu2-xSe/GO@Pt/SPCE). These findings convincingly demonstrate that Pt NPs possess a profound catalytic effect on H2O2. Notably, the Cu2-xSe/GO@Pt/SPCE exhibited the largest reduction peak current. Subsequently, i-t tests were conducted on the corresponding sensing electrodes at the reduction potentials observed in the CV curves. The i-t curves presented in Figure 3C align with the CV curves, offering consistent results. With the continuous addition of 0.1 mM H2O2, the current signal presented a stepped response, and the Cu2-xSe/GO@Pt/SPCE displayed the highest response current. Obviously, the above results confirmed that the catalytic reduction of H2O2 by the sensing electrode was mainly attributed to the Pt NPs on the electrodes. When comparing the two substrate materials, Mxene and GO nanosheets, it is evident that the latter is a more suitable support material for Cu2-xSe NPs and an effective electrodeposition reducer for Pt NPs, thanks to its constructed three-dimensional porous structure. Furthermore, except for Cu2-xSe/SPCE, the reduction peak current signals of CV curves of other electrodes gradually increased with increasing H2O2 concentration (0-5 mM), while the reduction peak potential shifted slightly in the negative direction (Figure 3D; Supplementary Figure S5).

In order to gain a deeper understanding of the catalytic kinetic process of H2O2 on the electrode, we conducted CV studies to measure the catalytic current signals of 5 mM H2O2 on Cu2-xSe/GO@Pt/SPCE at different scanning rates. As displayed in Figure 3E, a gradually increasing scan rate ranging from 20 to 300 mV s-1 resulted in an increase in the reduction current. Additionally, a strong linear relationship was observed between the peak current and the square root of the scanning rate (see Figure 3F), indicating that the catalytic process is highly dependent on the scan rate. The equation describing this relationship is provided below:

i(μA)=283.60v12(V/s1/2)+13.67(R2 =0.993)

By scrutinizing the catalytic reduction reaction of H2O2 on Cu2-xSe/GO@Pt/SPCE, we’ve ascertained that it’s an irreversible process, controlled by diffusion. This observation underscores the exceptional electrocatalytic activity of Cu2-xSe/GO@Pt/SPCE. Consequently, we selected this material for a more detailed examination of its sensitivity in detecting H2O2.

To optimize detection parameters, we conducted chronoamperometry (i-t) to study the effect of Cu2-xSe/GO@Pt/SPCE on the catalytic performance of H2O2 at different operating potentials (-0.36 V~-0.4 V). As depicted in Figure S6A, as the voltage increased from -0.36 V to -0.4 V, the response current of Cu2-xSe/GO@Pt/SPCE to H2O2 rises gradually. However, upon further voltage increment, the response current does not continue to climb, and even slightly decreased. Clearly, this suggests that Cu2-xSe/GO@Pt/SPCE reaches peak catalytic performance for H2O2 at -0.4V. Therefore, -0.4V was chosen as the operating potential for the subsequent experiments.

Additionally, we evaluated the linear relationship between Cu2-xSe/GO@Pt/SPCE’s response to H2O2 at an operating potential of -0.4V through i-t measurements. At the same time, considering the optical characteristics of Cu2-xSe NPs, the method of near infrared illumination was used to improve the catalytic effect of Cu2-xSe/GO@Pt/SPCE on H2O2. In addition, in order to investigate the effect of the content of Pt NPs on the electrochemical performance of the sensor electrode enhanced by NIR, we tested the i-t curves of the sensor electrode with different deposition times. Supplementary Figure S7A displays the amperometric response of Cu2-xSe/GO@Pt/SPCE with successive injection of 100 μM H2O2 at different deposition times with 808 nm laser. When the deposition time is greater than 200s, the growth of current signal tends to be stable. Thus, 200 s of deposition time was used for subsequent experiments. As Figure 4A clearly illustrates, regardless of whether 808 nm laser irradiation was used, the continuous addition of H2O2 solution with increasing concentration to a 10 mL 0.01M PBS solution led to a rapid step-type response of the reduction current of Cu2-xSe/GO@Pt/SPCE. This response reached a stable state within a few seconds (<5s), highlighting the electrode’s exceptional response speed and its ability to catalyze H2O2 rapidly. Obviously, under 808 nm laser irradiation, the Cu2-xSe/GO@Pt/SPCE displayed a significantly larger response current to H2O2, indicating that the laser could enhance the electrode’s catalytic effect on H2O2. Moreover, Figure 4B presents the i-t curves of the low concentration region (10~50 μm) in Figure 4A, in which the improvement of H2O2 catalytic performance of Cu2-xSe/GO@Pt/SPCE by 808 nm laser at low concentration could be more clearly seen. Figure 4C further illustrates the linear relationship curves between the current signal and H2O2 concentration, both without and with 808 nm laser irradiation. The corresponding linear fitting equation is as follows: i(μA)=0.033CH2O2(μM)0.033(R2=0.990) without laser) and i(μA)=0.045CH2O2(μM)0.311(R2=0.997), with 808 nm laser). Based on the above linear fitting equation, the detection limits without laser irradiation and under 808 nm laser irradiation could be calculated as 1.45μM and 0.53 μM, respectively (LOD=3σSd). Compared to the other electrochemical sensors and other detection methods in Supplementary Table S1, a relatively low detection limit is obtained at Cu2-xSe/GO@Pt/SPCE. findings underscore the critical role of near-infrared illumination in enhancing the H2O2 catalytic performance of Cu2-xSe/GO@Pt/SPCE. This exceptional enhancement effect under NIR light is primarily attributed to the local surface plasmon resonance (LSPR) of Cu2-xSe NPs. which generated more charge carriers on the electrode surface under laser irradiation, and these charge carriers then reacted with H2O2 to produce a larger response current.

Figure 4
www.frontiersin.org

Figure 4 (A) Amperometric response of Cu2-xSe/GO@Pt/SPCE at potential of−0.4 V (without laser and with 808 nm laser) with the successive addition of various amounts of H2O2; (B) the magnified parts of (A) at low H2O2 concentrations; (C) Calibration curves between electrocatalytic current of Cu2-xSe/GO@Pt/SPCE and H2O2 concentration within a range of 10−1500 μM without laser (gray line) and with 808 nm laser (red line); (D) The study of the selectivity, amperometric responses of the Cu2-xSe/GO@Pt/SPCE to the successive dropwise additions of 0.1 mM H2O2 and 1 mM interfering species (Gly, CA, AA, Urea and GSH).

In practical applications, the selectivity and reproducibility of the sensor are paramount considerations. We evaluated these factors by monitoring the interference of several potential interfering substances (glycine (Gly), citric acid (CA), ascorbic acid (AA), urea, glutathione (GSH)) on the detection of H2O2 using Cu2-xSe/GO@Pt/SPCE with i-t curve. As illustrated in Figure 4D, even at higher concentrations (1 mM), Gly, CA, AA, urea and GSH did not produce any discernible amperometric response when compared to H2O2 (100 μM). These results suggested the remarkable selectivity for H2O2 electrochemical detection. Furthermore, we measured the current response of five Cu2-xSe/GO@Pt/SPCE sensing electrodes to 300 μM H2O2 with i-t curves and repeated the test six times for each electrode (Supplementary Figure S8). The relative standard deviation (RSD) among electrodes was calculated to be 8.27%, indicating excellent reproducibility of the sensor.

Detection of H2O2 released from living cells at Cu2-xSe/GO@Pt/SPCE

The concentration of H2O2 in living cells is a significant biological parameter associated with wound inflammation treatment. Therefore, in this study, L929 cells and RAW 264.7 cells were selected as model cells, and the fLMP drug was used to stimulate the release of H2O2 within them. The microscopic images of L929 cells and RAW 264.7 cells displayed in Supplementary Figure S9, L929 cells exhibit fibroblast-like characteristics and grow close to the cell wall, while RAW 264.7 cells possess a small, translucent, and rounded morphology. Figure 5A provides a schematic diagram demonstrating how fLMP stimulates cells to produce H2O2, which is then rapidly detected followed by rapid detection of H2O2 by Cu2-xSe/GO@Pt/SPCE. By utilizing Cu2-xSe/GO@Pt/SPCE as the sensing electrode, the cells were stimulated to release H2O2 upon the addition of the fLMP drug to two distinct cell suspensions, and the signal of H2O2 was then determined by the i-t measurement (Figures 5B, C). When compared to a bare SPCE electrode, the Cu2-xSe/GO@Pt/SPCE sensing electrode exhibited significant reduction currents for H2O2 produced under different concentrations of fLMP (20 μM, 40 μM) stimulation within both cell suspensions, suggesting that the Cu2-xSe/GO@Pt nano-mimetic enzyme exhibits remarkable catalytic activity towards H2O2. The reduction currents generated by the bare SPCE electrode and the Cu2-xSe/GO@Pt/SPCE sensing electrode stimulated with the same concentration of fLMP (40 μM) in both cell suspensions are shown in Supplementary Figure S10, and there is a strong significant difference between the two sets of data, which further suggests that the catalytic reduction of H2O2 is mainly attributed to the Cu2-xSe/GO@Pt nanomimetic enzyme. In particular, the i-t curve of the Cu2-xSe/GO@Pt/SPCE retained a significant H2O2 response peak even when a lower concentration (8 μM) of fLMP solution was added to the L929 cell suspension (Supplementary Figure S11). This further highlights the outstanding catalytic activity of the Cu2-xSe/GO@Pt nanomimetic enzyme. The magnitude of the current response across the curves demonstrated that the amount of H2O2 produced by the cells increased in direct correlation with the concentration of fLMP. Additionally, as shown in Figure 5D, the magnitudes of the reaction currents in both cell suspensions were 0.046 μA, 0.066 μA (L929) and 0.029 μA, 0.123 μA (RAW 264.7) when fLMP was added in the amounts of 20 μM and 40 μM, respectively, indicating that fLMP promotes the dose-dependent release of H2O2 from the cells. These findings suggest that Cu2-xSe/GO@Pt offers immense potential as a biomimetic enzyme material for determining H2O2 released from living cells. This novel approach could significantly enhance our understanding of the mechanisms of ROS action in wound inflammation and pave the way for simplified monitoring of ROS dynamics in inflammatory environments.

Figure 5
www.frontiersin.org

Figure 5 (A) Demonstration of a pathway for H2O2 production by human cells and a scheme for the timely capture of H2O2 by sensing electrodes in response to drug stimulation; (B) i-t response of the Cu2-xSe/GO@Pt/SPCE sensing platform to the different concentration addition of fMLP stimulation with and without living L929 cells (7*107) at an applied potential of -0.40 V in 0.01 M PBS buffer (pH=7.4); (C) i-t response of the Cu2-xSe/GO@Pt/SPCE sensing platform to the different concentration addition of fMLP stimulation with and without living RAW 264.7 cells (8*107) at an applied potential of -0.40 V in 0.01 M PBS buffer (pH=7.4); (D) the corresponding average value of the i-t responses (n=3).

Conclusions

In conclusion, our work has resulted in the successful synthesis of a NIR-enhanced Cu2-xSe/GO@Pt/SPCE sensing electrode. This non-enzymatic current electrode demonstrates high selectivity, a low detection limit (0.53 μM) and wide linear range (10 μM-1500 μM) for H2O2 detection. The GO nanosheets not only build a solid three-dimensional structure for the anchoring of Cu2-xSe nanorods and the electrodeposition of Pt NPs, but also provide additional ion/electron transport channels for electrochemical reactions. The localized surface plasma effect of Cu2-xSe further enhances the catalytic effect of the electrode on H2O2 under near-infrared illumination conditions by promoting the separation of photogenerated electron-hole pairs in the Cu2-xSe@Pt heterojunction. Furthermore, the Cu2-xSe/GO@Pt/SPCE enables rapid capture of the reduction current signal of H2O2 release from living cells in L929 and RAW 264.7 cell suspension, allowing for in situ real-time detection. Overall, this Cu2-xSe/GO@Pt/SPCE sensing electrode offers superior performance, cost-effectiveness, simple preparation steps, and high reproducibility, making it a promising candidate for real-time in situ detection of biomolecules. This innovation holds the potential to transform the field of wound inflammation treatment by offering clinicians a robust method for promptly and precisely assessing ROS levels, ultimately enhancing patient outcomes.

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author/s.

Author contributions

MS: Writing – review & editing, Writing – original draft, Methodology, Formal Analysis, Data curation, Conceptualization. XD: Writing – review & editing, Writing – original draft, Methodology, Data curation. DN: Writing – original draft, Methodology. HX: Writing – original draft, Methodology. YZ: Writing – original draft, Investigation. GC: Writing – original draft, Formal Analysis, Data curation. ZR: Writing – original draft, Data curation. MC: Writing – review & editing, Conceptualization. MG: Writing – review & editing, Funding acquisition, Conceptualization. JB: Project administration, Methodology, Writing – review & editing, Writing – original draft, Funding acquisition, Formal Analysis, Conceptualization.

Funding

The author(s) declare financial support was received for the research, authorship, and/or publication of this article. The authors thank the financial support from the National Natural Science Foundation of China (Grant No. 32371473 and 82030066), the Chongqing Natural Science Foundation (CSTB2022NSCQ-MSX0151), Chongqing medical scientific research project (2023QNXM001), the Army Military Medical University Southwest Hospital doctor youth lift project (2024BQTJ-3) and the start-up foundation for introduced talent of Army Medical University (No. ZH2019-152).

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fimmu.2024.1392259/full#supplementary-material

References

1. Zheng D, Liu J, Piao H, Zhu Z, Wei R, Liu K. ROS-triggered endothelial cell death mechanisms: Focus on pyroptosis, parthanatos, and ferroptosis. Front Immunol. (2022) 13:1039241. doi: 10.3389/fimmu.2022.1039241

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Dunnill C, Patton T, Brennan J, Barrett J, Dryden M, Cooke J, et al. Reactive oxygen species (ROS) and wound healing: the functional role of ROS and emerging ROS-modulating technologies for augmentation of the healing process. Int Wound J. (2017) 14:89–96. doi: 10.1111/iwj.12557

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Kwon N, Kim D, Swamy KMK, Yoon J. Metal-coordinated fluorescent and luminescent probes for reactive oxygen species (ROS) and reactive nitrogen species (RNS). Coordination Chem Rev. (2021) 427:213581. doi: 10.1016/j.ccr.2020.213581

CrossRef Full Text | Google Scholar

4. Liu X, Wei Q, Sun Z, Cui S, Wan X, Chu Z, et al. Small extracellular vesicles: Yields, functionalization and applications in diabetic wound management. Interdiscip Med. (2023) 1:e20230019. doi: 10.1002/INMD.20230019

CrossRef Full Text | Google Scholar

5. Lin W, Shen P, Song Y, Huang Y, Tu S. Reactive oxygen species in autoimmune cells: function, differentiation, and metabolism. Front Immunol. (2021) 12. doi: 10.3389/fimmu.2021.635021

CrossRef Full Text | Google Scholar

6. Tang S, Zhang H, Mei L, Dou K, Jiang Y, Sun Z, et al. Fucoidan-derived carbon dots against Enterococcus faecalis biofilm and infected dentinal tubules for the treatment of persistent endodontic infections. J Nanobiotechnology. (2022) 20:321. doi: 10.1186/s12951-022-01501-x

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Huang X, He D, Pan Z, Luo G, Deng J. Reactive-oxygen-species-scavenging nanomaterials for resolving inflammation. Mater Today Bio. (2021) 11:100124. doi: 10.1016/j.mtbio.2021.100124

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Bassoy EY, Walch M, Martinvalet D. Reactive oxygen species: do they play a role in adaptive immunity? Front Immunol. (2021) 12:755856. doi: 10.3389/fimmu.2021.755856

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Wang M, Zheng Y, Yin C, Dai S, Fan X, Jiang Y, et al. Recent Progress in antibacterial hydrogel coatings for targeting biofilm to prevent orthopedic implant-associated infections. Front Microbiol. (2023) 14. doi: 10.3389/fmicb.2023.1343202

CrossRef Full Text | Google Scholar

10. Tu W, Xiao X, Lu J, Liu X, Wang E, Yuan R, et al. Vanadium exposure exacerbates allergic airway inflammation and remodeling through triggering reactive oxidative stress. Front Immunol. (2023) 13. doi: 10.3389/fimmu.2022.1099509

CrossRef Full Text | Google Scholar

11. Giaretta JE, Duan H, Oveissi F, Farajikhah S, Dehghani F, Naficy S. Flexible sensors for hydrogen peroxide detection: A critical review. ACS Appl Mater Interfaces. (2022) 14:20491–505. doi: 10.1021/acsami.1c24727

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Liu X, He L, Yang L, Geng Y, Yang L, Song X. Iminocoumarin-based fluorescence probe for intracellular H2O2 detection with a red emission and a large Stokes shift. Sensors Actuators B: Chem. (2018) 259:803–8. doi: 10.1016/j.snb.2017.12.140

CrossRef Full Text | Google Scholar

13. Peng Y, Yu L, Sheng M, Wang Q, Jin Z, Huang J, et al. Room-temperature synthesized iron/cobalt metal-organic framework nanosheets with highly efficient catalytic activity toward luminol chemiluminescence reaction. Anal Chem. (2023) 95:18436–42. doi: 10.1021/acs.analchem.3c03538

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Li P, Zhang S, Xu C, Zhang L, Liu Q, Chu S, et al. Coating Fe3O4 quantum dots with sodium alginate showing enhanced catalysis for capillary array-based rapid analysis of H2O2 in milk. Food Chem. (2022) 380:132188. doi: 10.1016/j.foodchem.2022.132188

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Ko M, Lim JS, Jang J-W, Joo SH. Bias-free photoelectrochemical H2O2 production and its in situ applications. ACS ES&T Eng. (2023) 3:910–22. doi: 10.1021/acsestengg.3c00053

CrossRef Full Text | Google Scholar

16. Riaz MA, Chen Y. Electrodes and electrocatalysts for electrochemical hydrogen peroxide sensors: a review of design strategies. Nanoscale Horiz. (2022) 7:463–79. doi: 10.1039/D2NH00006G

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Liu J, Li X, Cheng L, Sun J, Xia X, Zhang X, et al. Atomic layer deposition of Pt nanoparticles onto Co/MoN nanoarrays for improved electrochemical detection of H(2)O(2). Chem Commun (Camb). (2023) 59:474–7. doi: 10.1039/D2CC05521J

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Li Q, Fu S, Wang X, Wang L, Liu X, Gao Y, et al. Electrochemical and photoelectrochemical detection of hydrogen peroxide using cu(2)O/cu nanowires decorated with tiO(2-x) deriving from MXenes. ACS Appl Mater Interfaces. (2022) 14:57471–80. doi: 10.1021/acsami.2c19531

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Jiang Y, Xu X, Lu J, Yin C, Li G, Bai L, et al. Development of ϵ-poly(L-lysine) carbon dots-modified magnetic nanoparticles and their applications as novel antibacterial agents. Front Chem. (2023) 11. doi: 10.3389/fchem.2023.1184592

CrossRef Full Text | Google Scholar

20. Zhao A, She J, Manoj D, Wang T, Sun Y, Zhang Y, et al. Functionalized graphene fiber modified by dual nanoenzyme: Towards high-performance flexible nanohybrid microelectrode for electrochemical sensing in live cancer cells. Sensors Actuators B: Chem. (2020) 310:127861. doi: 10.3390/act9020031

CrossRef Full Text | Google Scholar

21. Wang H, Chen W, Chen Q, Liu N, Cheng H, Li T. Metal-organic framework (MOF)-Au@Pt nanoflowers composite material for electrochemical sensing of H2O2 in living cells. J Electroanalytical Chem. (2021) 897:115603. doi: 10.1016/j.jelechem.2021.115603

CrossRef Full Text | Google Scholar

22. Zhu JH, Gou H, Zhao T, Mei LP, Wang AJ, Feng JJ. Ultrasensitive photoelectrochemical aptasensor for detecting telomerase activity based on Ag(2)S/Ag decorated ZnIn(2)S(4)/C(3)N(4) 3D/2D Z-scheme heterostructures and amplified by Au/Cu(2+)-boron-nitride nanozyme. Biosens Bioelectron. (2022) 203:114048. doi: 10.1016/j.bios.2022.114048

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Zhang L, Meng W, Chen X, Wu L, Chen M, Zhou Z, et al. Multifunctional nanoplatform for mild microwave-enhanced thermal, antioxidative, and chemotherapeutic treatment of rheumatoid arthritis. ACS Appl Mater Interfaces. (2023) 15:10341–55. doi: 10.1021/acsami.2c19198

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Qiu L, Lv P, Zhao C, Feng X, Fang G, Liu J, et al. Electrochemical detection of organophosphorus pesticides based on amino acids conjugated nanoenzyme modified electrodes. Sensors Actuators B: Chem. (2019) 286:386–93. doi: 10.1016/j.snb.2019.02.007

CrossRef Full Text | Google Scholar

25. Zheng H, Cheng F, Guo D, He X, Zhou L, Zhang Q. Nanoenzyme-reinforced multifunctional scaffold based on ti(3)C(2)Tx MXene nanosheets for promoting structure-functional skeletal muscle regeneration via electroactivity and microenvironment management. Nano Lett. (2023) 23:7379–88. doi: 10.1021/acs.nanolett.3c01784

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Xing L, Rong Q, Ma Z. Non-enzymatic electrochemical sensing of hydrogen peroxide based on polypyrrole/platinum nanocomposites. Sensors Actuators B: Chem. (2015) 221:242–7. doi: 10.1016/j.snb.2015.06.078

CrossRef Full Text | Google Scholar

27. Wu N, Jiao L, Song S, Wei X, Cai X, Huang J, et al. Tuning the ratio of pt(0)/pt(II) in well-defined pt clusters enables enhanced electrocatalytic reduction/oxidation of hydrogen peroxide for sensitive biosensing. Anal Chem. (2021) 93:15982–9. doi: 10.1021/acs.analchem.1c03362

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Dong L, Ren S, Zhang X, Yang Y, Wu Q, Lei T. In-situ synthesis of Pt nanoparticles/reduced graphene oxide/cellulose nanohybrid for nonenzymatic glucose sensing. Carbohydr Polym. (2023) 303:120463. doi: 10.1016/j.carbpol.2022.120463

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Jesus EC, Santiago D, Casillas G, Mayoral A, Magen C, Jose-Yacaman M, et al. Platinum electrodeposition on unsupported single wall carbon nanotubes and its application as methane sensing material. J Electrochem Soc. (2012) 160:H98–H104. doi: 10.1149/2.054302jes

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Chen D, Zhuang X, Zhai J, Zheng Y, Lu H, Chen L. Preparation of highly sensitive Pt nanoparticles-carbon quantum dots/ionic liquid functionalized graphene oxide nanocomposites and application for H2O2 detection. Sensors Actuators B: Chem. (2018) 255:1500–6. doi: 10.1016/j.snb.2017.08.156

CrossRef Full Text | Google Scholar

31. Qi H, Song J, Fu Y, Wu X, Qi H. Highly dispersive Pt-Pd nanoparticles on graphene oxide sheathed carbon fiber microelectrodes for electrochemical detection of H(2)O(2) released from living cells. Nanotechnology. (2020) 31:135503. doi: 10.1088/1361-6528/ab60ce

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Tong Y, Wang L, Song J, Zhang M, Qi H, Ding S, et al. Self-terminated electroless deposition of surfactant-free and monodispersed pt nanoparticles on carbon fiber microelectrodes for sensitive detection of H2O2 released from living cells. Analytical Chem. (2021) 93:16683–9. doi: 10.1021/acs.analchem.1c04299

CrossRef Full Text | Google Scholar

33. Mandavkar R, Kulkarni R, Ahasan Habib M, Burse S, Lin S, Kunwar S, et al. Super-porous Pt/CuO/Pt hybrid platform for ultra-sensitive and selective H2O2 detection. Appl Surface Sci. (2022) 593, 153454. doi: 10.1016/j.apsusc.2022.153454

CrossRef Full Text | Google Scholar

34. Ma J, Chen G, Bai W, Zheng J. Amplified electrochemical hydrogen peroxide sensing based on cu-porphyrin metal-organic framework nanofilm and G-quadruplex-hemin DNAzyme. ACS Appl Mater Interfaces. (2020) 12:58105–12. doi: 10.1021/acsami.0c09254

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Dai Y, Zhu X, Liu H, Lin Y, Sun W, Sun Y, et al. Morphology-dependent electrochemical behavior of 18-facet Cu(7)S(4) nanocrystals based electrochemical sensing platform for hydrogen peroxide and prostate specific antigen. Biosens Bioelectron. (2018) 112:143–8. doi: 10.1016/j.bios.2018.03.020

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Lie SQ, Wang DM, Gao MX, Huang CZ. Controllable copper deficiency in Cu2-xSe nanocrystals with tunable localized surface plasmon resonance and enhanced chemiluminescence. Nanoscale. (2014) 6:10289–96. doi: 10.1039/C4NR02294G

PubMed Abstract | CrossRef Full Text | Google Scholar

37. Bao J, Wang Y, Li C, Yang C, Xu H, Liang Q, et al. Gold-promoting-satellite to boost photothermal conversion efficiency of Cu2-Se for triple-negative breast cancer targeting therapy. Materials Today Nano. (2022) 18:100211. doi: 10.1016/j.mtnano.2022.100211

CrossRef Full Text | Google Scholar

38. Zhang Y, Gao W, Ma Y, Cheng L, Zhang L, Liu Q, et al. Integrating Pt nanoparticles with carbon nanodots to achieve robust cascade superoxide dismutase-catalase nanozyme for antioxidant therapy. Nano Today. (2023) 49:101768. doi: 10.1016/j.nantod.2023.101768

CrossRef Full Text | Google Scholar

Keywords: wound inflammation, H2O2 detection, peroxidase (POD) mimetic, electrochemical sensing, Cu2-xSe/GO@Pt

Citation: Shen M, Dai X, Ning D, Xu H, Zhou Y, Chen G, Ren Z, Chen M, Gao M and Bao J (2024) Integrating Pt nanoparticles with 3D Cu2-xSe/GO nanostructure to achieve nir-enhanced peroxidizing Nano-enzymes for dynamic monitoring the level of H2O2 during the inflammation. Front. Immunol. 15:1392259. doi: 10.3389/fimmu.2024.1392259

Received: 11 March 2024; Accepted: 03 July 2024;
Published: 17 July 2024.

Edited by:

Patrick M Honore, CHU UCL Namur Site Godinne, Belgium

Reviewed by:

Qihui Zhou, University of Health and Rehabilitation Sciences, China
Qiuyu Gong, The First Affiliated Hospital of Xi’an Jiaotong University, China

Copyright © 2024 Shen, Dai, Ning, Xu, Zhou, Chen, Ren, Chen, Gao and Bao. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Ming Chen, Y2htaW5nMTk3MUAxMjYuY29t; Mingxuan Gao, bWluZ3h1YW5fZ2FvQDE2My5jb20=; Jing Bao, YmFvamluZ18xOTkxQDE2My5jb20=

These authors have contributed equally to this work

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.