This work considers using a novel heuristic population-based evolutionary algorithm [viz., the moth flame optimization (MFO) algorithm] to regulate the conventional controller installed in an autonomous power system (APS). The moth flame optimization algorithm intends to produce the optimal magnitudes of the proportional-integral-derivative plus second derivative (PIDD2) controller parameters along with its first- and second-order low-pass filter constraints (installed in the investigated autonomous power system). The present task includes a comparison of the voltage response profiles of the investigated system obtained by the proposed moth flame optimization-based proportional-integral-derivative plus second derivative controller and those obtained by other algorithms (conveyed in current state-of-the-art literature) based on a proportional-integral controller. A fast-acting Sugeno fuzzy logic (SFL) technique is used to achieve the dynamic online results of the investigated autonomous power system model for online, off-nominal operational circumstances. Under step perturbations, the time-domain transient investigation in reference to voltage and/or mandate of load for the proposed autonomous power system model is inspected. Additionally, the robustness of the proposed moth flame optimization-based proportional-integral-derivative plus second derivative controller is investigated to test its behavior. An investigation has been provided by varying the model components of the studied autonomous power system model. It may be reported, as per the results obtained from the simulation, that the proposed moth flame optimization-based proportional-integral-derivative plus second derivative controller is an effective control strategy for the autonomous power system. The current research effort indicates that the proposed moth flame optimization algorithm, along with Sugeno fuzzy logic, may be useful for the actual time process of an autonomous power system.
1 Introduction
Power sector deregulation, increased environmental concern, and sustainable development/supply security make the power system extremely decentralized; as a result, it is largely responsible for the shift from large central generation to scalable distributed generation (DG). DG generates electricity in smaller quantities closer to end users (Huda and Zivanovic, 2017), which remarkably boosts energy efficiency, reduces carbon emissions, improves grid resilience, and curbs the requirement for new transmission investments. However, in order to effectively use DG technology, the various generators have to be synchronized and fine-tuned to sustainably serve the growing digital and automated infrastructures, and excess energy in low load-demand conditions must be fed to the grid efficiently. Thus, fine-tuning various distributed generators for the system to efficiently carry out these functions introduces a new set of problems to the power system, necessitating the development of new techniques to keep up with the trail of these challenges. As a result, the focus of this work is primarily to model and optimize an optimal automatic voltage regulator (AVR) controller for the autonomous distributed power model.
Regardless of the load condition, the AVR loop guarantees that the voltage profile remains within acceptable limits by constantly tracking the generator terminal voltage and correcting the generator exciter voltage accordingly. Thus, for effective AVR performance, a controller is often incorporated in the loop, and as a result, different controllers such as proportional integral PI (Hussain et al., 2017), (Eke et al., 2021), proportional integral derivative PID and its variants (Lahcene et al., 2017; Sambariya and Gupta, 2017; Blondin et al., 2018; Mosaad et al., 2018; Ali et al., 2020; Bhullar et al., 2020; Veinovi, 2022), integral double derivative with filter IDDF (Rajbongshi and Saikia, 2017), and many others (Moschos and Parisses, 2022), (Sikander et al., 2018) have been investigated over the years for AVR control. However, optimal controller parameter tuning is achieved by employing various techniques such as metaheuristic optimization techniques, artificial intelligence techniques, or a combination of the two to maximize the benefits of each distinct approach.
Metaheuristic optimization techniques are collections of coherent and effective intelligent techniques used to solve complex, high-order, non-linear engineering problems even with time delays; their efficacy and consistency can be seen in almost all power systems disciplines such as operation, control, scheduling, and energy management (Ma et al., 2016; Ayalew et al., 2019; Bukar and Tan, 2019; Ghalambaz et al., 2021; Rodrigues et al., 2021), although of significant importance AVR control is well highlighted in (Hussain et al., 2017), (Sambariya and Gupta, 2017), (Lahcene et al., 2017), (Mosaad et al., 2018), (Moschos and Parisses, 2022), (Banerjee et al., 2012; Gözde et al., 2017; Bourouba et al., 2019; Mosaad et al., 2019; Jumani et al., 2021; Micev et al., 2021), a brief and comprehensive study, particularly on the new metaheuristic technique used on AVR, can be seen in (Kouba and Boudour, 2019) and (Oladipo et al., 2020). However, despite being a promising technique for solving engineering problems, the metaheuristic optimization technique often suffers from inefficiency due to difficult parameter tuning and non-assurance of convergence because its performance is highly dependent on fine parameter tuning (Madic et al., 2013). As a result, few parameters or parameter-free techniques, as seen in Mosaad et al. (2018), Bhullar et al. (2020), Eke et al. (2021), are required for greater performance.
Artificial intelligence techniques, on the other hand, execute tasks that typically require human intelligence, and their ability to operate in real time is of particular interest. In generally, when AI techniques are used to tune controller parameters or to optimize a process, consistently good results are obtained, as seen in Elsisi (2019); but their operation requires complex analysis with a long convergence time (Mosaad et al., 2018).
However, a good balance, particularly between exploration and exploitation, is achieved by hybridization; thus, superior performance is guaranteed when these techniques are combined, as seen in (Al Gizi et al., 2015a; Al Gizi et al., 2015b; Al Gizi, 2019; Ali and Khaniki, 2020; Mokeddem and Mirjalili, 2020; Ozgenc et al., 2020). Hence, this work is focused on modeling and optimizing an autonomous distributed power system using a high-performance proportional-integral-derivative-second order derivative (PIDD2) controller improved using the Moth flame optimization (MFO) technique (Mirjalili, 2015) and/or in conjunction with real-time Sugeno fuzzy logic (SFL). MFO was suggested and well deliberated in Mirjalili (2015), and has been used since then in different fields (Shehab et al., 2020), including power systems, as seen in Mohanty (2019), Chatterjee et al. (2020), Chatterjee and Mohammed (2022). Moreover, MFO variants were well studied in literature; the authors of (Nadimi-Shahraki et al., 2021a) propose a migration-based moth-flame optimization (M-MFO) technique that is projected to avoid risk of local optima entrapment. The primary focus of M-MFOs is on taming the location of unlucky moths by traveling them stochastically in the initial iterations using an arbitrary migration (RM) operator, sustaining the result modification by distinctly storing new skilled results in a controlling archive, and finally manipulating around the locations protected in the controlling archive using a guided migration (GM) operator. Further, an improved moth-flame optimization (I-MFO) algorithm is proposed by the authors of (Nadimi-Shahraki et al., 2021b) to deal with established MFO problems by positioning stuck moths in local optima by defining memory for each moth. The stuck moths have a tendency to eliminate the local optima by using the enhanced wandering around search (AWAS) strategy. Also, (Nadimi-Shahraki et al., 2022) postulated an operational hybridization of the whale optimization algorithm (WOA) and an improved moth-flame optimization algorithm (MFO) named WMFO to resolve the OPF problem. The WOA and the improved MFO work together in the WMFO to effectively determine capable zones and offer high-quality results.
It should be noted that the introduction of SFL to carry parameter specifications in real-time makes the techniques presented here behave as if they are parameter-free, allowing for easy achievement of good balance. Consequently, the main objectives of this work are:
a) To tune the offline parameters of the PIDD2 controller using the MFO technique for the APS being considered.
b) To explore the utility and applicability of SFL-based controller tuning in online real-time situations.
c) To compare the voltage profile response obtained from the proposed technique with that acquired by other studied techniques.
d) To investigate the model’s performance for a wide range of important system parameters and disturbances for practical implementation.
2 Methodology
2.1 Power system modeling
A standard distributed energy generator (DEG) consisting of an AVR, speed governor, and controller is depicted in Figure 1; the upper half of the blocks are the mechanical model of the speed governor with an integrator of gain
The generator inertia (H), damping constant (D), and governor controller variables are the key features influencing frequency aberration. On a diesel engine, the inertia constant (H) can be documented as the ratio of energy deposited in revolving components of the diesel generator to the rated apparent power, whereas the actuator is normally implemented to refer to the fuel system’s actuator, which controls the volume of diesel fuel inserted into the engine. The transfer function of Eqs 2–4 models the DEG, valve actuator, inertia, and load of the power system under consideration, where
The AVR system comprises four major parts: a generator, an exciter, an amplifier, and a sensor. The sensor detects the voltage at the synchronous generator’s terminal indefinitely. The signal is rectified and smoothed and then directed to the comparator for comparison with a pre-set signal. The comparator’s voltage error is then amplified through the amplifier and directed to the exciter to regulate the windings of an alternator field. Furthermore, the transfer function of an amplifier, exciter, and generator is modeled by a gain and a time constant, as shown in Eqs 5–7, where
2.2 Controller modeling
Unlike the conventional PID controller, which has three main components for improving system performance, the PIDD2 controller employed here has an additional component called second-order derivative gain
However, two low-pass filters have been employed in the controller design for smoother and better response; these are the first-order low-pass filter for first-order derivatives and a second-order low-pass filter for second-order derivatives in their corresponding tracks, as shown in Eqs 9, 10. Thus, the overall transfer function of the employed PIDD2 controller can be represented by Eq. 11 where
The suitability of the proposed technique is assessed by a flexible time domain performance index known as the “figure of merit” (FOD), represented in Eq. 12; it is implemented using the system’s essential dynamic attributes based on desired specifications and constraints. Consequently, the main target of this optimization task is to minimize FOD, which is directly dependent on the system’s transient response parameters. It should be noted that the
2.3 SFL for online tuning of the PIDD2 controller
Fuzzy control deviates from conventional control theories to a greater extent because it attempts to model logical reasoning with a vague statement rather than the usual true or false. Sugeno fuzzy logic (SFL) is an efficient fuzzy control technique for a system with fast-changing dynamics like AVR; it can modify the controller’s parameters with precision even online and in a real-time environment. Real-time operations guarantee that balance is achieved between load and generation at all times by making the best use of asynchronous data and control to accommodate changing conditions and delays in communication; fuzzy control is extensively discussed in (Mohagheghi and Harley, 2004). Figure 2 shows the structure of a fuzzy logic-based PIDD2 controller, the implementation of which necessitates two inputs to yield a control signal
The incremental change in error shown in Eq. 14 is the difference between the change in reference voltage and the change in terminal voltage, whereas the derivative of incremental change in error shown in Eq. 15 is the rate of change of incremental change in error, where
These two inputs (
3 MFO overview
Moth Flame Optimization (MFO) is inspired by moth night navigation features; fundamentally, MFO mimics the unwanted behavior of moths while navigating in the presence of artificial light and performs its optimization. MFO was proposed and extensively discussed in (Mirjalili, 2015), and it has since been used in a variety of fields (Shehab et al., 2020), including power systems, as seen in (Mohanty, 2019; Chatterjee et al., 2020; Chatterjee and Mohammed, 2022). It is a population-based algorithm that employs two important components: moths and flames. Therefore, it is randomly initiated in space by establishing candidate solutions (moths), then computing their fitness levels and aligning with the flames, which is the best position moths can reach. Afterward, exploitation and exploration are adaptively ensured by a progressive and systematic reduction in the number of flames; thus, for a moth to attain a greater position, it must update its position over and over again according to the position of the flame until convergence is achieved, at which point the process is terminated. The relevant equations required for executing the algorithm are established in (Mirjalili, 2015; Shehab et al., 2020; Chatterjee and Mohammed, 2022), and the general formulation for implementing the MFO algorithm as used in APS is specified in Algorithm 1, (Chatterjee and Mohammed, 2022).
3.1 MFO algorithm
The MFO algorithm assumes that the moths are the candidate result and that their location in space is the variable quantity of the problem. As a result, the moths can fold away in 1-d, 2-d, 3-d, or hyper-dimensional space by changing their location vectors. Because this is a population-based algorithm, the set of moths is described in a matrix that is well-defined in Eq. 16 (Mirjalili, 2015)
Where
It is assumed that there is an array of the corresponding fitness magnitudes for all moths, as stated in Eq. 17 (Mirjalili, 2015).
It should be noted that the fitness magnitude for each moth will be the return magnitude of the fitness (objective) function. The fitness function sends the location vector (1st row in the matrix
The MFO algorithm has an additional critical component known as flames, for which, similar to the moth matrix, an additional matrix is used as shown in Eq. 18 (Mirjalili, 2015).
It is clear from Eq. 18 that the size of
Individually, the moths and flames (both of which are results) differ because their magnitudes change in each iteration. Moths are actual searching agents that travel from place to place in the search space, with flames being the best location attained so far.
The MFO algorithm is a three-tuple that estimates the global desirable solution for the optimization issues and is expressed in Eq. 20 (Mirjalili, 2015).
In Eq. 20,
The function
If the conclusion condition is fulfilled, then the function
The overall form of the MFO algorithm is defined in Algorithm 1:.
Algorithm 1:. Overall form of the MFO algorithm (Mirjalili, 2015).
M=I();
while T(M) is equal to fasle
M=P(M);
end
The function
Algorithm 2:. Computation of the objective function (Mirjalili, 2015).
for i=1: n
for j=1: d
M (i,j)=(ub(i)-Ib(i))*rand()+1b(i);
end
end
OM=Fitness Function(M)
In Algorithm 2, there are two additional arrays named
where
where
The location of individual moths is improved with respect to a flame implementation Eq. 26 (Mirjalili, 2015).
where
A logarithmic spiral, as used in the MFO algorithm in (Mirjalili, 2015), is presented in Eq. 27.
where
The variable quantity
where
The spiral traveling technique of moths is described in Eq. 27. According to the equation, the succeeding location of a moth is described with respect to flame. The spiral technique instructs the moths to inform flames about their locations, making it the main portion of the proposed methodology. The spiral equation allows a moth to hover around a flame. As a result, the search space can be guaranteed for its exploration and exploitation.
The chances of discovering better outcomes can be ensured by taking the best results so far as flames. Hence, the current best results attained are stowed in the matrix
Similar flames aid the moths in varying their locations. The first moth constantly modifies its location with respect to the best flame, while the last moth modifies its position with respect to the worst flame. In the search space, with respect to
The equation in Eq. 29 can be implemented in this context (Mirjalili, 2015):
where
Algorithm 3:. Overall stages of function
Update flame number using (29)
OM=Fitness Function (M)
If iteration==1
F=sort (M);
OF=sort (OM);
else
F=sort(Mt-1,Mt);
OF=sort(Mt-1,Mt);
end
for i=1:n
for j=1:d
Update r and t
Calculate D using (28) with respect to the corresponding moth
Update M(i,j) using (26) and (27) with respect to the corresponding moth
end
end
4 Results and discussion
An autonomous fuel cell distributed power system depicted in Figure 1, with system parameters presented in Appendix A (Banerjee et al., 2012), is considered here for AVR systematic investigation, along with an exceptional proportional-integral-derivative-second order derivative (PIDD2) controller; the controller was tuned both offline and online by MFO and SFL-MFO techniques under varying generator gain and time constants. Also evaluated is system performance (specifically voltage response) under various disturbances and uncertainties. As a result, the important findings of this research are discussed below, with the results of particular interest highlighted in the respective tables. All simulations were carried out in MATLAB/SIMULINK (version 7.10) on a 2.77 GHz, Intel Core™ i7 computer, with the maximum number of iterations and population size set to 100 and 50 for each algorithm.
4.1 Comparison of transient response characteristics
In this section, the transient characteristics of the system are investigated and compared under two conditions: distinct gain and time constant of the generator (
4.2 First condition: Distinct and
In the first case, the transient characteristics of the system with varying gain and generator time constant values for the various techniques considered (proposed and studied) are examined and then compared for the same set of
4.3 Second condition: Distinct and
In this condition, the transient characteristics of the system for the different techniques considered (proposed and studied) are examined and compared for the distinct values of reference voltage and load perturbation
FIGURE 6. Comparison of transient characteristics for distinct disturbances at
4.4 Convergence
The comparative convergence profile, which was established by plotting the minimum FOD value against the number of iterations (as shown in Figure 7), demonstrates the high performance of the proposed technique; indeed, it converges faster and offers a lower FOD value as compared to the other techniques considered in this work.
4.5 Robustness analysis
Due to parametric uncertainties, models are an imperfect representation of reality. Consequently, a controller that is perfectly tuned to a model may reduce system performance or stability. To avoid this problem, the MFO-based PIDD2 technique edge is checked using robustness analysis by systematically subjecting the model to broad variations of some essential parameters, such as
FIGURE 8. Voltage response profile of the MFO-optimized and PIDD2-controlled APS with variations in- (A)
4.6 SFL real-time response
Having obtained outstanding results with the MFO-based PIDD2 technique offline, SFL control is introduced into the system for parameter specification online and in real-time, yielding the online optimum controller gains, transient characteristics, and FOD values at a different set of
5 Conclusion
This work used an autonomous distributed power model to conduct a comprehensive investigation. First, the model was investigated offline using the MFO-PIDD2 technique, which gave an excellent transient response that died out and settled faster than other techniques considered. Furthermore, the comparative convergence and robustness analyses clearly demonstrated the high performance and flexibility of the technique. Also, the study was expanded to operate in online mode by synchronizing real-time SFL with the MFO-PIDD2, which gave improved control that outperformed other online techniques used in this study. Lastly, the techniques presented here demonstrate improved resilience with better control and coordination than previous techniques offered in the recent literature on the model; thus, the technique can be used as an effective instrument for enhancing systems with identical or similar specifications.
Data availability statement
The raw data supporting the conclusion of this article will be made available by the authors, without undue reservation.
Author contributions
All authors listed have made a substantial, direct, and intellectual contribution to the work and approved it for publication.
Funding
This paper is based upon work supported by Science, Technology and Innovation Funding Authority (STDF) under grant number (43180).
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
References
Al Gizi, A. J. H. (2019). A particle swarm optimization, fuzzy PID controller with generator automatic voltage regulator. Soft Comput. 23, 8839–8853. doi:10.1007/s00500-018-3483-4
Al Gizi, A. J. H., Mustafa, M. W., Al zaidi, K. M. A., and Al-zaidi, M. K. J. (2015). Electrical power and energy systems integrated PLC-fuzzy PID simulink implemented AVR system. Int. J. Electr. Power Energy Syst. 69, 313–326. doi:10.1016/j.ijepes.2015.01.009
Al Gizi, A. J. H., Mustafa, M. W., Al-geelani, N. A., and Alsaedi, M. A. (2015). Sugeno fuzzy PID tuning, by genetic-neutral for AVR in electrical power generation. Appl. Soft Comput. J. 28, 226–236. doi:10.1016/j.asoc.2014.10.046
Ali, M., and Khaniki, L. (2020). Feedback error learning controller based on RMSprop and salp swarm algorithm for automatic voltage regulator system,” in 10th International Conference on Computer and Knowledge Engineering (ICCKE), 425–430. 2020 October.
Ali, Z. M., Hasanien, H. M., Abdel, S. H. E., Micev, M., and Martin, C. (2020). Optimal design of automatic voltage regulation controller using hybrid simulated annealing – manta ray foraging optimization algorithm. Ain Shams Eng. J. 12, 641–657. doi:10.1016/j.asej.2020.07.010
Ayalew, F., Hussen, S., and Pasam, G. K. (2019). Optimization techniques in power system: Review. Int. J. Eng. Appl. Sci. Technol. 3, 8–16.
Banerjee, A., Mukherjee, V., and Ghoshal, S. P. (2012). Seeker optimization algorithm for load-tracking performance of an autonomous power system. Int. J. Electr. Power Energy Syst. 43, 1162–1170. doi:10.1016/j.ijepes.2012.06.066
Bhullar, A. K., Kaur, R., Sondhi, S., Bhullar, A. K., Kaur, R., and Sondhi, S. (2020). Optimization of fractional order controllers for AVR system using distance and levy-flight based crow search algorithm. IETE J. Res., 1–18.
Blondin, M. J., Sanchis, J., Sicard, P., and Herrero, J. M. (2018). New optimal controller tuning method for an AVR system using a simplified Ant Colony Optimization with a new constrained Nelder-Mead algorithm. Appl. Soft Comput. J. 62, 216–229. doi:10.1016/j.asoc.2017.10.007
Bourouba, B., Ladaci, S., and Schulte, H. (2019). Optimal design of fractional order PIλDμ controller for an AVR system using Ant Lion Optimizer. IFAC Pap. 52, 200–205. doi:10.1016/j.ifacol.2019.11.304
Bukar, A. L., and Tan, C. W. (2019). A review on stand-alone photovoltaic-wind energy system with fuel cell: System optimization and energy management strategy. J. Clean. Prod. 221, 73–88. doi:10.1016/j.jclepro.2019.02.228
Chatterjee, S., and Mohammed, A. N. (2022). “Performance evaluation of novel moth flame optimization (MFO) technique for AGC of hydro system,” in IOT with smart systems. Smart innovation, systems and technologies, springer nature Singapore, 251, 377–392.
Chatterjee, S., Shiva, C. K., and Mukherjee, V. (2020). “Automatic generation control of multi-area hydro power system using moth flame optimization technique,” in 3rd International Conference on Recent Developments in Control, Automation and Power Engineering (RDCAPE), 395–403.
Eke, I., Saka, M., Gozde, H., Arya, Y., and Taplamacioglu, M. C. (2021). Heuristic optimization based dynamic weighted state feedback approach for 2DOF PI-controller in automatic voltage regulator. Eng. Sci. Technol, Int. J. 24, 899–910. doi:10.1016/j.jestch.2020.12.023
Elsisi, M. (2019). Design of neural network predictive controller based on imperialist competitive algorithm for automatic voltage regulator. Neural comput. Appl. 31, 5017–5027. doi:10.1007/s00521-018-03995-9
Ghalambaz, M., Jalilzadeh, R., and Hossein, A. (2021). Building energy optimization using grey wolf optimizer (GWO). Case Stud. Therm. Eng. 27, 101250. doi:10.1016/j.csite.2021.101250
Gözde, H., Taplamacioglu, M. C., and Ari, M. (2017). “Simulation study for global neighborhood algorithm based optimal automatic voltage regulator (AVR) system,” in 5th International Istanbul Smart Grid and Cities Congress and Fair (ICSG), 46–50.
Huda, A. S. N., and Zivanovic, R. (2017). Large-scale integration of distributed generation into distribution networks: Study objectives, review of models and computational tools. Renew. Sustain. Energy Rev. 76, 974–988. doi:10.1016/j.rser.2017.03.069
Hussain, I., Das, D. C., and Sinha, N. (2017). Reactive power performance analysis of dish – stirling solar thermal – diesel hybrid energy system. IET Renew. Power Gener. 11, 750–762. doi:10.1049/iet-rpg.2016.0579
Jumani, A., Khan, I., Hamadneh, N. N., and Khan, A. (2021). Optimal design of fractional order PID controller based automatic voltage regulator system using gradient-based optimization algorithm. J. King Saud. Univ. - Eng. Sci. Article in Press. doi:10.1016/j.jksues.2021.07.009
Kouba, N. E. L. Y., and Boudour, M. (2019). A brief review and comparative study of nature-inspired optimization algorithms applied to power system control. Cham: Springer.
Lahcene, R., Abdeldjalil, S., and Aissa, K. (2017). “Optimal tuning of fractional order PID controller for AVR system using simulated annealing optimization algorithm,” in IEEE 2017 5th International Conference on Electrical Engineering - Boumerdes (ICEE-B), 1–6.
Ma, K., Yao, T., Yang, J., and Guan, X. (2016). Residential power scheduling for demand response in smart grid. Int. J. Electr. Power Energy Syst. 78, 320–325. doi:10.1016/j.ijepes.2015.11.099
Madic, M., Markovic, D., and Radovanovic, M. (2013). Comparison of meta-heuristic algorithms for solving machining optimization problems. Facta Univ. Mech. Eng. 11, 29–44.
Micev, M., Calasan, M., and Oliva, D. (2021). Design and robustness analysis of an Automatic Voltage Regulator system controller by using Equilibrium Optimizer algorithm. Comput. Electr. Eng. 89, 106930. doi:10.1016/j.compeleceng.2020.106930
Mirjalili, S. (2015). Moth-flame optimization algorithm: A novel nature-inspired heuristic paradigm. Knowledge-Based Syst. 89, 228–249. doi:10.1016/j.knosys.2015.07.006
Mohagheghi, S., and Harley, R. G. (2004). “Modified takagi-sugeno fuzzy logic based controllers for a static compensator in a multimachine power system,” in IEEE Industry Applications Conference, 2637–2642.
Mohanty, B. (2019). Performance analysis of moth flame optimization algorithm for AGC system. Int. J. Model. Simul. 39, 73–87. doi:10.1080/02286203.2018.1476799
Mokeddem, D., and Mirjalili, S. (2020). Improved Whale Optimization Algorithm applied to design PID plus second-order derivative controller for automatic voltage regulator system. J. Chin. Inst. Eng. 43, 541–552. doi:10.1080/02533839.2020.1771205
Mosaad, A. M., Attia, M. A., and Abdelaziz, A. Y. (2018). Comparative performance analysis of AVR controllers using modern optimization techniques. Electr. Power Components Syst. 46, 2117–2130. doi:10.1080/15325008.2018.1532471
Mosaad, A. M., Attia, M. A., and Abdelaziz, A. Y. (2019). Whale optimization algorithm to tune PID and PIDA controllers on AVR system. Ain Shams Eng. J. 10, 755–767. doi:10.1016/j.asej.2019.07.004
Moschos, I., and Parisses, C. (2022). A novel optimal PIλDND2N2 controller using coyote optimization algorithm for an AVR system. Eng. Sci. Technol. Int. J. 26, 100991. doi:10.1016/j.jestch.2021.04.010
Nadimi-Shahraki, M. H., Fatahi, A., Zamani, H., Mirjalili, S., Abualigah, L., and Abd Elaziz, M. (2021). Migration-based moth flame optimization algorithm. Processes 9, 2276. doi:10.3390/pr9122276
Nadimi-Shahraki, M. H., Fatahi, A., Zamani, H., Mirjalili, S., and Abualigah, L. (2021). An improved moth-flame optimization algorithm with adaptation mechanism to solve numerical and mechanical engineering problems. Entropy 23, 1637. doi:10.3390/e23121637
Nadimi-Shahraki, M. H., Fatahi, A., Zamani, H., Mirjalili, S., and Oliva, D. (2022). Hybridizing of whale and moth-flame optimization algorithms to solve diverse scalesof optimal power flow problem. Electronics 11, 831.
Oladipo, S., Sun, Y., and Wang, Z. (2020). “Optimization of PID and FOPID controllers with new generation metaheuristic algorithms for controlling AVR system: Concise Survey,” in Proc: 2020 12th International Conference on Computational Intelligence and Communication Networks (CICN), 280–286. 25-26 September.
Ozgenc, B., Ayas, M. S., and Altas, I. H. (2020). “A hybrid optimization approach to design optimally tuned PID controller for an AVR system,” in International congress on human computer interaction, optimization and robotic application (HORA), 1–5.
Rajbongshi, R., and Saikia, L. C. (2017). Combined control of voltage and frequency of multi-area multisource system incorporating solar thermal power plant using LSA optimised classical controllers. IET Gener. Transm. Distrib. Res. 11, 2489–2498. doi:10.1049/iet-gtd.2016.1154
Rodrigues, F., Molina, Y., Silva, C., and Naupari, Z. (2021). Simultaneous tuning of the AVR and PSS parameters using particle swarm optimization with oscillating exponential decay. Int. J. Electr. Power Energy Syst. 133, 107215. doi:10.1016/j.ijepes.2021.107215
Sambariya, D. K., and Gupta, T. (2017). “Optimal design of PID controller for an AVR system using monarch butterfly optimization,” in IEEE, International Conference on Information, Communication, Instrumentation and Control, 1–6.
Shehab, M., Abualigah, L., Al, H., Hamzeh, H., Mohammad, A., and Khasawneh, A. M. (2020). Moth – flame optimization algorithm: Variants and applications. Neural comput. Appl. 32, 9859–9884. doi:10.1007/s00521-019-04570-6
Sikander, A., Thakur, P., Bansal, R. C., and Rajasekar, S. (2018). A novel technique to design cuckoo search based FOPID controller for AVR in power systems. Comput. Electr. Eng. 70, 261–274. doi:10.1016/j.compeleceng.2017.07.005
Veinovi, S. (2022). Optimized four-parameter PID controller for AVR systems with respect to robustness. Int. J. Electr. Power Energy Syst. 135 (2022), 107529.
Glossary
The following abbreviations are used in this document:
Appendix A
Keywords: autonomous distributed power system, moth flame optimization (MFO) technique, Sugeno fuzzy logic, real time operation, PIDD 2 controller.
Citation: Chatterjee S, Mohammed AN, Mishra S, Sharma NK, Selim A, Bajaj M, Rihan M and Kamel S (2023) Optimal real-time tuning of autonomous distributed power systems using modern techniques. Front. Energy Res. 11:1055845. doi: 10.3389/fenrg.2023.1055845
Received: 28 September 2022; Accepted: 10 February 2023;
Published: 10 March 2023.
Edited by:
Xu Chen, Jiangsu University, ChinaReviewed by:
Banaja Mohanty, Veer Surendra Sai University of Technology, IndiaMohammad H. Nadimi-Shahraki, Torrens University Australia, Australia
Deepak Kumar Lal, Veer Surendra Sai University of Technology, India
Copyright © 2023 Chatterjee, Mohammed, Mishra, Sharma, Selim, Bajaj, Rihan and Kamel. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Mohit Bajaj, thebestbajaj@gmail.com; Salah Kamel, skamel@aswu.edu.eg