Skip to main content

ORIGINAL RESEARCH article

Front. Environ. Sci., 01 December 2022
Sec. Water and Wastewater Management
This article is part of the Research Topic Advanced Physico-Chemical Technologies for Water Detoxification and Disinfection View all 7 articles

Comparison of ultrasound and UV technologies to control bulking and foaming in a wastewater treatment facility. A case study in an industrial park in Morelos, Mexico

Jesús Hernndez-RomanoJesús Hernández-RomanoLuis Trevino-QuintanillaLuis Trevino-QuintanillaAnglica Guilln-GarcsAngélica Guillén-GarcésMartín Barragn-TrinidadMartín Barragán-TrinidadVictoria Bustos-TerronesVictoria Bustos-TerronesDiana K. Díaz de AndaDiana K. Díaz de AndaGabriela Moeller-Chvez
Gabriela Moeller-Chávez*
  • Universidad Politécnica del Estado de Morelos, Jiutepec, Mexico

Most wastewater treatment plants use activated sludge-based biological systems for this purpose. The latter must effectively remove organic matter and, at the same time, show good sedimentability. However, sometimes there is an excessive proliferation of certain bacteria, giving rise to filamentary swelling, compromising the excellent sedimentability of the sludge. In this sense, the study’s objective was to evaluate the effect of applying two different technologies, the application of low-frequency ultrasound and UV radiation. Some bench-scale experiments were performed using the bulked sludge from the secondary clarifier of a wastewater treatment facility in an industrial park (CIVAC) in Morelos, Mexico, affected by filamentous organisms. Results showed that for the UV application for two, four, and 6 min, the settleability of the mixed liquor suspended solids was not improved; on the other hand, the cavitation effect caused by the ultrasound application demonstrated effective action against the destruction of filamentous organisms. The 10 min condition showed a significant decrease in the filament integrity of the microorganisms and a significant improvement of sedimentation velocity and sludge volume index (SVI) values and settleability of the sludge, but not enough to satisfy national discharge regulations related to total suspended solids in the treated effluent. Molecular identification indicates the presence of the genera Thauera and Brevundimonas in the sludge.

1 Introduction

The activated sludge system is the most common aerobic process to treat industrial wastewater. Due to its effectiveness releases a high-quality treated effluent with more than 95% of organic matter and solids removal. Under normal conditions in activated sludge, bacteria occur singly, in small chains or clumps. Under adverse conditions, certain bacterial species undergo incomplete cell division, causing the resulting cells not to separate, but remain associated with each other, generating “branches” or “filaments”; as these structures dominate the wastewater treatment system, they can interfere with settling and may cause foaming upon aeration. These conditions are expected to be present during the operation of some industrial wastewater treatment facilities due to several situations, such as the high toxicity of some specific effluents. Bulking sludge is defined as sludge with a sludge volume index (SVI) of more than 150 ml/g (Bitton, 2005). These problems could adversely affect effluent quality and is often presented as the growth of dispersed or non-settleable biomass, and a pin floc appears and alters the efficiency of the sedimentation process. As soon as these problems are detected, the goal is to control the presence of those organisms that change the settleability of the mixed liquor.

Conditions that cause bulking in a facility are described in Table 1 (Richard, 2003).

TABLE 1
www.frontiersin.org

TABLE 1. Some conditions cause bulking in a wastewater treatment facility (Adapted from Richard (2003)).

Different control techniques are employed to try to solve this problem. Two strategies exist: specific or non-specific: The non-specific methods include some oxidation techniques applying chemicals like chlorine, ozone, and hydrogen peroxide. The most common oxidant used is chlorine, which is cheap and widely available, and used by more than 50% of facilities. However, there is a fear of the organo-halogens formed and discharged in final effluents to receiving waters (Toprak Home Page, 2006; Yilmaz et al., 2008). On the other hand, specific methods are those preventive methods that aim to favor the growth of floc-forming bacterial structures against filamentous bacterial structures. The challenge is to find and maintain the appropriate environmental conditions in an activated sludge treatment plant to reach this goal. If this is impossible and the problem is present, the operator has to solve it and apply specific control methods.

Advanced Oxidation Processes (AOP), a set of non-conventional treatments, are implemented to treat domestic and industrial wastewater when conventional treatments are not effective or as a complement to these for the degradation of recalcitrant molecules such as organic micropollutants and/or inactivation of pathogens (Titchou et al., 2021). Most AOP are based on combining a strong oxidant (such as ozone or hydrogen peroxide) with a catalyst (transition metals or photocatalysts). However, some are based on electromagnetic radiation, such as ultraviolet (UV) radiation and ultrasound. In addition, the latter does not require the addition of external chemical agents to generate hydroxyl radicals (·OH), a highly oxidizing agent that can cause the oxidation of most organic compounds (Sharma et al., 2018; Titchou et al., 2021).

Ultrasound has been successfully applied to inactivate pathogens and remove contaminants present in wastewater (Vázquez-López et al., 2019), as well as for the hydrolysis of activated sludge (Al-Hoqani et al., 2022). Ultrasound transducers transform electrical current into mechanical energy and generate mechanical vibrations and acoustic cavitation (the phenomenon of growth and collapse of bubbles due to the action of acoustic waves). Acoustic cavitation simultaneously causes physical, chemical, and mechanical phenomena that cause adverse effects on bacteria and other cellular structures (David and Cheeke, 2017). On the other hand, irradiation of water with UV light in the 150–200 nm range (UV-C) can decompose water into hydroxyl radicals and hydrogen atoms (Jin et al., 2017). However, the lamps usually used in disinfection systems attached to wastewater treatment plants use a higher wavelength (close to 250 nm). These types of lamps have a germicidal action as a result of the damage caused by UV radiation to the genetic material (DNA and RNA), resulting in the death of microorganisms and its application in the disinfection of water for human consumption (Song et al., 2016) and elimination of pathogens (and organic micropollutants) in effluents from wastewater treatment plants is well documented (Masschelein and Rice, 2002; Yang et al., 2014). In this sense, both ultrasound and UV radiation could break the filamentary structures of voluminous sludge and improve the sedimentation properties of the activated sludge.

This paper aimed to study the effect of the application of UV irradiation and low-frequency ultrasound technology on the disintegration of filamentous biomass present in the mixed liquor tank of an activated sludge industrial wastewater treatment plant. It is assumed that the application of these technologies will improve the settleability of the sludge, the values of the volumetric sludge index, and, therefore, the reduction of the suspended solids content in the effluent.

2 Materials and methods

2.1 Industrial wastewater (IWW) sludge sampling

ECCACIV (Empresa para el Control de la Contaminación del Agua de la Ciudad Industrial del Valle de Cuernavaca) is a private wastewater treatment facility constructed to treat the wastewater generated in an industrial corridor in the valley of Cuernavaca in Morelos, Mexico. The technology used is aerobic technology (Biotowers/Krofta) and treats 210 L/s of mixed municipal wastewater from the surrounding area and wastewater discharges coming from the industrial facilities located at the corridor.

Suspended solids samples were obtained from the secondary clarifier (Figure 1). Collection, preservation, and analysis were made weekly, following the Standard Methods procedures (APHA et al., 2005). The sampling period was during 2 months when the problem of floating and foaming in the clarifier appeared (Figure 2). The settled sludge volume was determined on-site. The Mixed liquor suspended solids determination and the filamentous bacteria observation, UV, and sonication treatment were carried out at the laboratory installations.

FIGURE 1
www.frontiersin.org

FIGURE 1. Suspended solids sample from the secondary clarifier.

FIGURE 2
www.frontiersin.org

FIGURE 2. Sludge with bulking and foaming problems.

2.2 Experimental set-up

2.2.1 Ultrasound application

Experiments were performed using the following conditions and equipment:

a) Sonication device: A Cole-Parmer CP505 sonication equipment.

b) Operational parameters: 20kHz, 35% amplitude, and an ultrasonic density of 3333.3 W/L.

c) Sonication times: 5 and 10 min (no temperature control was used).

d) Sample volume: 160 ml of mixed liquor.

Experiments were performed in a batch system. Figure 3 shows a schematic diagram of the sonolysis reactor and an image of the equipment used. Between each application, the tip of the sonicator was washed with sterile water.

FIGURE 3
www.frontiersin.org

FIGURE 3. Diagram of the experimental set-up and the Cole Parmer. Mod. CP505 sonicator.

2.2.2 UV light application

A commercial UV sterilization system (PROUV24-24, InstaPura, United States ) was used (Figure 4). The reactor consisted of a 55 × 11 × 08 cm stainless steel cylinder containing a concentric quartz tube (TC-UV20.88). A UV light lamp (LG-UV21W, United States ) with an emission length of 254 nm, an input voltage of 120 V (60 Hz), and an output power of 25 W was located inside the reactor. The treatment was applied in batch mode at a volume of mixed liquor of 140 ml for 2, 4, and 6 min. Before and after the treatment, the sonicator device was washed with sterile distilled water.

FIGURE 4
www.frontiersin.org

FIGURE 4. UV light experimental device used for treating mixed liquor with UV light.

2.3 Tracking parameters

These parameters were performed before and after applying ultrasound and UV radiation to the sludge samples from the secondary clarifier.

2.3.1 Physico-chemical parameters

The content of total suspended solids (TSS) and the sludge volume index (SVI) were determined based on standard methods (APHA et al., 2005). On the other hand, total dissolved solids (TDS) and pH were measured with portable multiparameter equipment (PCSTestr 35, ThermoScientific, United States ).

2.3.2 Microbiological parameters

Since two layers could be distinguished in the mixed liquor samples from the clarifier: supernatant (SN), and sediment (SD), both layers were analyzed for each sample for this test. Methylene blue was used to stain the filamentous bacteria in the sludge samples. For this purpose, 20 µl of the sample was diluted with 100 µl of distilled water, and 100 µl of the dilution was fixed on a slide and stained with two drops of methylene blue (500 mg/L). The samples were washed and allowed to dry before direct microscopic observation (ZEISS, Germany).

2.4 Identification of bacteria and molecular analysis

To obtain isolated colonies, SN and SD samples were subject to decimal dilutions using sterile nutritive broth added with wastewater (1:1) to enrich the culture medium with the components required by microorganisms; then, 100 μl of each dilution were seeded in nutritive agar plates prepared using wastewater, the liquid was spread with sterile glass beads. The seeded plates were incubated for 24 h at 30°C. To obtain pure cultures, each isolated colony was grown in nutrient broth (supplemented with sterile wastewater) for 24 h at 30°C. Subsequently, genomic DNA was extracted from each pure culture using the Genomic DNA Purification Wizard kit (Promega, United States ) according to the manufacturer’s instructions. Next, the amplification of the 16 S rRNA gene was carried out using the universal primers fD1 (5′-AGA​GTT​TGA​TCC​TGG​CTC​AG-3′) and rP2 (5′-ACG​GCT​ACC​TTG​TTA​CGA​CTT-3′) (Weisburg et al., 1991). PCR Master Mix 2X (K0171, ThermoFisher Scientific) was used in a 50 µl reaction volume. First, the reaction tube was subjected to 94°C for 2 min, then to 35 amplification cycles at 94°C for 15 s, 59°C for 15 s, and 72°C for 1 min 30 s, finally to 72°C for 5 min. To assess the obtaining of the desired PCR products, electrophoresis was run on 1% agarose (90V/50 min) stained with ethidium bromide, using a DNA molecular weight marker (SM1373, ladder 2, ThermoFisher Scientific) as a reference. Finally, the DNA Clean and Concentrator-5 kit (Zymo Research, United States ) was used to purify the amplicons. The purified PCR products were sent for sequencing (Sanger sequencing) to the Institute of Biotechnology of the UNAM (Cuernavaca, Mexico). The sequences obtained were analyzed with Chromas (http://technelysium.com.au/wp/chromas/) and FinchTV (https://digitalworldbiology.com/FinchTV) software, and the fasta sequences were subject to a similarity analysis using BLAST (Altschul et al., 1990) to determine the genus of the organisms. The phylogenetic analysis for the Thauera genus was done using the partial sequences of the 16 S ribosomal gene with accession numbers ON222725.1, ON222726.1, MW741510.1, MW647554.1, MW510006.1, NR_026153.1, AB021377.1, AB681922.1, NR_024972.1, MN538255.1, AF229887.1, AF229867.1, MH251633.1, NR_025283.1, KY287941.1, NR_027224.1, EU434525.1, EU434481.1, NR_159313.1, NR_026474.1, NR_024850.1, and the 16 S sequence obtained from the whole genome with accession numbers NZ_CP014646.1 and NZ_CP029331.1, the 16 S gene sequences of Azoarcus communis with accession number NR_024850.1 was used as outgroup.

For the phylogenetic analysis of sequences related to the genus Brevundimonas, the partial sequences of the 16 S ribosomal gene with accession numbers ON222727.1, KT000269.1, DQ979376.1, MK850354.1, MK034262.1, MN989047.1, MN493912.1, and the 16 S sequence obtained from the whole genome with accession numbers CP035093.1, NZ_CP021995.1, NZ_CP066026.1, NZ_CP073063.1, NZ_CP062222.1, NZ_CP015614.1, NZ_CP032707.1, NZ_CP038027.1, NZ_CP080036.1, NZ_CP080034.1, NZ_CP062006.1, NC_014375.1, NZ_LR588407.1, NZ_CP022048.2, NZ_CP067977, NZ_CP048751.1, the 16 S sequence of Phenylbacterium parvum (NZ_CP029479.1) was used as outgroup. The phylogenetic tree was built with the program CLC Sequence Viewer V8.0, using UPGMA as the tree construction method and Jukes-Cantor as a nucleotide distance measure, with 100 replicates as bootstrapping.

3 Results and discussion

3.1 Effect of ultrasound and UV radiation on physicochemical and microbiological parameters

SVI quantification has been used as a standard method to determine the presence of filamentous bulking conditions. This parameter is considered the volume, in milliliters, of 1 G of suspended solids after 30 min of settling. A sludge with good sedimentation has SVI values of less than 150 ml/g, while a value greater than 200 ml/g indicates that the activated sludge system has bulking problems (Eikelboom, 2000; Bitton, 2005). Based on this criterion, it can be deduced that the sample of activated sludge taken from the treatment plant (PC, positive control) has bulking problems (Table 2), which is also accompanied by a high TSS content, greater than what is recommended by local standards (SEMARNAT, 2022).

TABLE 2
www.frontiersin.org

TABLE 2. Effect of the application of a five and 10 minutes of ultrasound and UV treatment to the bulked sludge from the secondary clarifier on SVI and TSS values in the final effluent.

After 10 min of ultrasound application, the SVI and TSS content of the mixed liquor sludge decreased to 53% and 89.9%, respectively. This is due to the effect of acoustic cavitation caused by sound waves, which leads to the breaking of cellular structures (David and Cheeke, 2017; Al-Hoqani et al., 2022), which could be revealed by microscope observations (Figure 5), where damage to the filament structure responsible for the bulking and foaming in the mixed liquor was evident. However, when applying 5 min of sonication to the mixed liquor samples, no drastic changes in the SVI were observed (only 14%), not consistent with the TSS reduction observed (and the microscopic observations that show there is damage to the filament structures). Several studies support the use of ultrasound to carry out the hydrolysis of activated sludge (Al-Hoqani et al., 2022) and the inactivation of pathogens present in them (Vázquez-López et al., 2019).

FIGURE 5
www.frontiersin.org

FIGURE 5. Optical microscopy of the mixed liquor before (PC) and after treatment with ultrasound (US 5 and US 10) and UV radiation (UV 2, UV 4, and UV 6).

On the other hand, when using UV radiation, although the TSS content decreased (32%–61%), the SVI values did not reduce significantly after applying said treatment (Table 2). Microscopic observations corroborate that UV radiation was inefficient in breaking down filamentous structures, and therefore there was no decrease in SVI values (Figure 5).

Although the application of ultrasound drastically decreased the TSS content in the effluent (even below the limits stipulated by the local standard) of the mixed liquor, it still cannot be considered to have good sedimentability due to its SVI values (>150 ml/g). This suggests that it is necessary to increase the power applied to the mixed liquor, increase the exposure times to the ultrasonic treatment, or apply combined treatments.

In addition to SVI and SST, changes in TDS and pH were also monitored (Table 3). TDS provides us with a measure of the degree of solubilization of activated sludge when exposed to both sonication and UV radiation. In both treatments, there was no increase in TDS; however, this is not consistent with the results of TSS (Table 2), where it was observed that there is a decrease in the values of this parameter for both treatments. It is worth mentioning that these results were obtained with a multiparametric equipment, so it is necessary to carry out the tests based on the standard methods (APHA et al., 2005) to corroborate the results obtained. Instead, the typical pH range of the water that comes out of the secondary clarifier ranges between 6–8.5, according to what was obtained in the present work. Various studies have shown that pH values below 6 promote the development of filamentous bulking (Jenkins et al., 2003; Agridiotis et al., 2007) because at this pH, the growth of filamentous microorganisms is favored. On the other hand, several studies have suggested that increasing the pH from 5 to 9 decreases the SVI; this is because the bacteria leave the isoelectric state, which increases the number of active sites in the cells that leads to an improvement in floc formation potential (Agridiotis et al., 2007); however, the results are not conclusive, suggesting that the sludge settling mechanisms are more complex.

TABLE 3
www.frontiersin.org

TABLE 3. Effect of the application of ultrasound and UV treatment on TDS and pH of the mixed liquor.

Power consumption is an essential factor to consider in large-scale ultrasound applications; However, there are few studies on this technology’s use to control sludge bulking. In addition, it has also been proven that the application of ultrasound helps to simultaneously eliminate nutrients, organic matter, and pathogenic microorganisms (Vázquez-López et al., 2019); so that the use of this emergent technology can be applied for other purposes. As its application spreads, this technology could evolve into a more effective and efficient process, including lower costs.

3.2 microorganisms present in liquor samples

Sanger sequencing results of the PCR products obtained with the oligonucleotides fD1/rP2 generated three electropherograms of DNA sequences, from which DNA sequences in Fasta format were derived and are available through the NCBI browser under the accession numbers ON222725.1, ON222726.1, ON222727.1. A similarity analysis with BLAST showed that two of the isolations belong to the Thauera genus. Phylogenetics analysis was done, showing that strains NC749 and B4PNR_027224.1 of Thaurea aminoaromatica and T. phenylacetica, respectively, were the closest species (Figure 6A). The third isolation belongs to the Brevundimonas genus, being Brevundimonas diminuta, the closest defined species (Figure 6B).

FIGURE 6
www.frontiersin.org

FIGURE 6. Phylogenetic trees showing the relationships of isolates ON222725.1 and ON222726.1 (A) and ON222727.1(B).

Previous reports indicate that some species of Thaurea have been associated with incomplete denitrification and form long chains (Song et al., 2001; Liu et al., 2013; Henze et al., 2017); a possible reason that explains the formation of bulking sludge during the clarification process, as well as isolated from activated sludge (Yin et al., 2017), having metabolic capabilities allowing to degrade recalcitrant compounds as phenol. The genus Brevundimonas has been used to remove nitrate from groundwater (Kavitha et al., 2009); therefore, it also could contribute to the formation of bulking sludge. Strains of this genus have been previously isolated from activated sludge of coking wastewater treatment plants, with metabolic capabilities that allowed the degradation of quinoline, a recalcitrant and toxic compound (Wang et al., 2015).

Although it was possible to identify two bacterial species associated with filamentous bulking, the strategy used requires obtaining pure cultures before Sanger sequencing. This imposes some limitations: 1) loss of species that cannot be cultivated; 2) loss of bacterial species in a low proportion in the bacterial community or with high nutritional requirements; 3) sample processing time; 4) Sanger sequencing not suitable for running multiple reactions in parallel. In this sense, high-throughput DNA sequencing methodologies (next-generation sequencing, NGS) constitute an alternative to solve the limitations as mentioned above at a lower cost (Cao et al., 2017; Slatko et al., 2018). Therefore, implementing this type of sequencing methodology is suggested to have a more complete overview of the bacterial community.

4 Conclusion

UV radiation did not damage the filamentous bacteria’s cellular structure; therefore, there was no improvement in the sedimentability of the mixed liquor-suspended solids. For its part, the use of ultrasound, and the cavitation effect achieved by its application, showed a significant improvement in the sedimentability of the sludge and the SVI values as a result of the destruction of the filamentous structures; however, it is necessary to increase the application time (10 min), combine both treatments (US and UV together), or consider combining UV with hydrogen peroxide in order to comply with national regulations.

Molecular identification indicates the presence of the Thauera and Brevundimonas genera as predominant in the filamentous muds. It is suggested to use metagenomic approaches using a next-generation sequencing-based on 16 S rRNA to have a broader picture of the bacterial community, as well as whole genome sequencing of the isolated microorganisms to elucidate metabolic capabilities potentially useful for bioremediation.

Data availability statement

The datasets presented in this study can be found in online repositories. The names of the repository/repositories and accession number(s) can be found in the article/Supplementary Material.

Author contributions

JH-R and GM-C: Conceptualization and design the experiments. MB-T, AG-G, and LT-Q: Writing and preparation of the original draft. DD: Methodology and experimentation. VB-T, JH-R, and GM-C: Resources, review, and editing of the manuscript. All authors reviewed and approved the manuscript.

Acknowledgments

The authors thanked the ECCACIV wastewater treatment plant for the samples, support of chemicals, and materials received to implement the research; to Engineers Maria José Alcaráz Castillo and Carlos Franco Rojas for their contribution to the experimental results of this research. The authors thanked UPEMOR for the support and funding of chemicals and materials received to implement the research.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

Agridiotis, V., Forster, C. F., and Carliell-Marquet, C. (2007). Addition of Al and Fe salts during treatment of paper mill effluents to improve activated sludge settlement characteristics. Bioresour. Technol. 98, 2926–2934. doi:10.1016/j.biortech.2006.10.004

PubMed Abstract | CrossRef Full Text | Google Scholar

Al-Hoqani, M., Zafar, Mohd., Al Musharafi, S. K., Mahanty, B., and Behera, S. K. (2022). COD fractionation and solubility assessment of sonicated waste-activated sludge. Environ. Qual. Mgmt. 31, 347–354. doi:10.1002/tqem.21789

CrossRef Full Text | Google Scholar

Altschul, S. F., Gish, W., Miller, W., Myers, E. W., and Lipman, D. J. (1990). Basic local alignment search tool. J. Mol. Biol. 215, 403–410. doi:10.1016/S0022-2836(05)80360-2

PubMed Abstract | CrossRef Full Text | Google Scholar

APHAAWWAWFE (2005). Standard methods for the examination of water & wastewater. 21st ed. Washington: American Public Health Association.

Google Scholar

Bitton, G. (2005). Wastewater microbiology. 3er ed. New Jersey: John Wiley & Sons.

Google Scholar

Cao, Y., Fanning, S., Proos, S., Jordan, K., and Srikumar, S. (2017). A review on the applications of next generation sequencing technologies as applied to food-related microbiome studies. Front. Microbiol. 8, 1829. doi:10.3389/fmicb.2017.01829

PubMed Abstract | CrossRef Full Text | Google Scholar

David, J., and Cheeke, N. Fundamentals and applications of ultrasonic waves (2017). 2nd ed. (Boca Raton: CRC Press). doi:10.1201/b12260

CrossRef Full Text | Google Scholar

Eikelboom, D. H. (2000). Process control of activated sludge plants by microscopic investigation. 1st edition. London, UK: IWA Publishing. Available at: https://library.oapen.org/handle/20.500.12657/30982 (Accessed March 15, 2022).

Google Scholar

Henze, M., van Loosdrecht, M. C., Ekama, G. A., and Brdjanovic, D. (2017). “Desarrollo del tratamiento de aguas residuales,” in Tratamiento biológico de aguas residuales: Principios, modelación y diseño (London UK: IWA Publishing), 1–8.

Google Scholar

Jenkins, D., Richard, M. G., and Daigger, G. T. (2003). Manual on the causes and control of activated sludge bulking, foaming, and other solids separation problems. 3rd ed. Boca Raton: CRC Press. doi:10.1201/9780203503157

CrossRef Full Text | Google Scholar

Jin, F., Wei, M., Liu, C., and Ma, Y. (2017). The mechanism for the formation of OH radicals in condensed-phase water under ultraviolet irradiation. Phys. Chem. Chem. Phys. 19, 21453–21460. doi:10.1039/C7CP01798G

PubMed Abstract | CrossRef Full Text | Google Scholar

Kavitha, S., Selvakumar, R., Sathishkumar, M., Swaminathan, K., Lakshmanaperumalsamy, P., Singh, A., et al. (2009). Nitrate removal using Brevundimonas diminuta MTCC 8486 from groundwater. Water Sci. Technol. 60, 517–524. doi:10.2166/wst.2009.378

PubMed Abstract | CrossRef Full Text | Google Scholar

Liu, B., Mao, Y., Bergaust, L., Bakken, L. R., and Frostegård, Å. (2013). Strains in the genus Thauera exhibit remarkably different denitrification regulatory phenotypes. Environ. Microbiol. 15, 2816–2828. doi:10.1111/1462-2920.12142

PubMed Abstract | CrossRef Full Text | Google Scholar

Masschelein, W. J., and Rice, R. G. (2002). Ultraviolet light in water and wastewater sanitation. 1st Edition. Boca Raton: CRC Press. doi:10.1201/9781420032178

CrossRef Full Text | Google Scholar

Richard, M. (2003). “Practical control methods for activated sludge bulking and foaming,” in Activated sludge microbiology problems and their control (Buffalo, NY: Buffalo Heritage Press), 12–21.

Google Scholar

SEMARNAT, (2022). Norma Oficial Mexicana NOM-001-SEMARNAT-2021, Que establece los límites permisibles de contaminantes en las descargas de aguas residuales en cuerpos receptores propiedad de la nación. Available at: https://www.dof.gob.mx/nota_detalle.php?codigo=5645374&fecha=11/03/2022 (Accessed March 15, 2022).

Google Scholar

Sharma, A., Ahmad, J., and Flora, S. J. S. (2018). Application of advanced oxidation processes and toxicity assessment of transformation products. Environ. Res. 167, 223–233. doi:10.1016/j.envres.2018.07.010

PubMed Abstract | CrossRef Full Text | Google Scholar

Slatko, B. E., Gardner, A. F., and Ausubel, F. M. (2018). Overview of next generation sequencing technologies. Curr. Protoc. Mol. Biol. 122, e59. doi:10.1002/cpmb.59

PubMed Abstract | CrossRef Full Text | Google Scholar

Song, B., Palleroni, N. J., Kerkhof, L. J., and Häggblom, M. M. (2001). Characterization of halobenzoate-degrading, denitrifying Azoarcus and Thauera isolates and description of Thauera chlorobenzoica sp. nov. Int. J. Syst. Evol. Microbiol. 51 (2), 589–602. doi:10.1099/00207713-51-2-589

PubMed Abstract | CrossRef Full Text | Google Scholar

Song, K., Mohseni, M., and Taghipour, F. (2016). Application of ultraviolet light-emitting diodes (UV-LEDs) for water disinfection: A review. Water Res. 94, 341–349. doi:10.1016/j.watres.2016.03.003

PubMed Abstract | CrossRef Full Text | Google Scholar

Titchou, F. E., Zazou, H., Afanga, H., El Gaayda, J., Ait Akbour, R., Nidheesh, P. V., et al. (2021). Removal of organic pollutants from wastewater by advanced oxidation processes and its combination with membrane processes. Chem. Eng. Process. - Process Intensif. 169, 108631. doi:10.1016/j.cep.2021.108631

CrossRef Full Text | Google Scholar

Toprak Home Page (2006). Chlorination of recycling. Available at: http://web.deu.edu.tr/atiksu/ana55/77ani.html (Accessed February 26, 2022).

Google Scholar

Vázquez-López, M., Amabilis-Sosa, L. E., Moeller-Chávez, G. E., Roé-Sosa, A., Neumann, P., and Vidal, G. (2019). Evaluation of the ultrasound effect on treated municipal wastewater. Environ. Technol. 40, 3568–3577. doi:10.1080/09593330.2018.1481889

PubMed Abstract | CrossRef Full Text | Google Scholar

Wang, C., Zhang, M., Cheng, F., and Geng, Q. (2015). Biodegradation characterization and immobilized strains’ potential for quinoline degradation by Brevundimonas sp. K4 isolated from activated sludge of coking wastewater. Biosci. Biotechnol. Biochem. 79, 164–170. doi:10.1080/09168451.2014.952615

PubMed Abstract | CrossRef Full Text | Google Scholar

Weisburg, W. G., Barns, S. M., Pelletier, D. A., and Lane, D. J. (1991). 16S ribosomal DNA amplification for phylogenetic study. J. Bacteriol. 173, 697–703. doi:10.1128/jb.173.2.697-703.1991

PubMed Abstract | CrossRef Full Text | Google Scholar

Yang, W., Zhou, H., and Cicek, N. (2014). Treatment of organic micropollutants in water and wastewater by UV-based processes: A literature review. Crit. Rev. Environ. Sci. Technol. 44, 1443–1476. doi:10.1080/10643389.2013.790745

CrossRef Full Text | Google Scholar

Yilmaz, I., Icemer, G., and Topkaya, B. (2008). Controlling options of bulking sludge. Fresenius Environ. Bull. 17, 1816–1821.

Google Scholar

Yin, Y., Wang, Y., Tang, W., and Song, L. (2017). Thauera phenolivorans sp. nov., a phenol-degrading bacterium isolated from activated sludge. Antonie Leeuwenhoek 110, 1681–1690. doi:10.1007/s10482-017-0918-3

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: filamentous bulking, foaming, advanced oxidation technologies, ultrasound, UV radiation

Citation: Hernández-Romano J, Trevino-Quintanilla L, Guillén-Garcés A, Barragán-Trinidad M, Bustos-Terrones V, Díaz de Anda DK and Moeller-Chávez G (2022) Comparison of ultrasound and UV technologies to control bulking and foaming in a wastewater treatment facility. A case study in an industrial park in Morelos, Mexico. Front. Environ. Sci. 10:919003. doi: 10.3389/fenvs.2022.919003

Received: 13 April 2022; Accepted: 16 November 2022;
Published: 01 December 2022.

Edited by:

Laura Norman, United States Department of the Interior, United States

Reviewed by:

Zacharias Frontistis, University of Western Macedonia, Greece
Virendra Kumar Yadav, Mody University of Science and Technology, India

Copyright © 2022 Hernández-Romano, Trevino-Quintanilla, Guillén-Garcés, Barragán-Trinidad, Bustos-Terrones, Díaz de Anda and Moeller-Chávez. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Gabriela Moeller-Chávez, gmoeller@upemor.edu.mx

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.