Skip to main content

ORIGINAL RESEARCH article

Front. Vet. Sci.
Sec. Veterinary Imaging
Volume 12 - 2025 | doi: 10.3389/fvets.2025.1533130

Magnetic Resonance Angiography for Cerebral Artery and Venous Visualization in Dogs: A Comparative Study of Time-of-Flight, Phase-Contrast, and Time-Resolved Imaging of Contrast Kinetics Sequences

Provisionally accepted
  • College of Veterinary Medicine, Seoul National University, Seoul, Republic of Korea

The final, formatted version of the article will be published soon.

    This study aims to compare the effectiveness of three magnetic resonance angiography (MRA) sequences-Time-of-Flight (TOF), Phase-Contrast (PC), and Time-Resolved Imaging of Contrast Kinetics (TRICKS)-in visualizing cerebral arteries and veins in dogs. The goal is to determine the most suitable MRA sequence for improving diagnostic accuracy in canine cerebral imaging. Five healthy adult beagles underwent imaging using a 1.5-T MRI system. Quantitative measures, including signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), were calculated, and qualitative evaluations of vessel delineation and visualization symmetry were performed by blinded observers. The three sequences were statistically compared using Friedman and Wilcoxon signed-rank tests. All dogs completed the imaging protocols without any complications. TOF MRA showed the best results for visualizing cerebral arteries, with the highest SNR and CNR in major arteries like the basilar, rostral, caudal cerebral, and caudal communicating arteries. TRICKS MRA performed better than TOF and PC for venous imaging, achieving higher SNR or CNR in most veins, including the transverse, temporal, straight sinus and dorsal cerebral vein, and had the shortest acquisition time. In qualitative evaluations, TOF MRA demonstrated acceptable or higher vascular visibility in most of brain arteries. All venous structures were significantly better visualized with TRICKS MRA compared to TOF MRA. Interobserver agreement was high, showing consistency in the results. These findings suggest that TOF is best for artery imaging, while TRICKS is ideal for venous imaging and faster procedures. TOF is recommended for clear and detailed imaging of cerebral arteries, while TRICKS is more suitable for imaging veins and situations where faster scans are needed. These results provide a basis for improving MRA techniques in veterinary medicine, helping to make diagnoses more accurate and procedures more efficient in both clinical practice and research.

    Keywords: DOG1, velocity encoding2, canine3, TWIST4, VENC5, MRI6

    Received: 23 Nov 2024; Accepted: 22 Jan 2025.

    Copyright: © 2025 Hong, KIM, Namgoong, Kwon, Yoon and Choi. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

    * Correspondence: Jihye Choi, College of Veterinary Medicine, Seoul National University, Seoul, Republic of Korea

    Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.