Skip to main content

CORRECTION article

Front. Vet. Sci., 01 February 2023
Sec. Veterinary Pharmacology and Toxicology

Corrigendum: Acute and subacute toxicity assessment of oxyclozanide in Wistar rats

\nWeiwei Wang,,Weiwei Wang1,2,3Zhen Dong,,Zhen Dong1,2,3Jili Zhang,,Jili Zhang1,2,3Xuzheng Zhou,,Xuzheng Zhou1,2,3Xiaojuan Wei,,Xiaojuan Wei1,2,3Fusheng Cheng,,Fusheng Cheng1,2,3Bing Li,,Bing Li1,2,3Jiyu Zhang,,
Jiyu Zhang1,2,3*
  • 1Key Laboratory of New Animal Drug Project of Gansu Province, Lanzhou, China
  • 2Key Laboratory of Veterinary Pharmaceutical Development, Ministry of Agriculture, Lanzhou, China
  • 3Lanzhou Institute of Husbandry and Pharmaceutical Sciences, Chinese Academy of Agricultural Sciences, Lanzhou, China

A corrigendum on
Acute and subacute toxicity assessment of oxyclozanide in Wistar rats

by Wang, W., Dong, Z., Zhang, J., Zhou. X., Wei, X., Cheng, F., Li, B., and Zhang, J. (2019). Front. Vet. Sci. 6:294. doi: 10.3389/fvets.2019.00294

In the published article Reference Manual of Laboratory Animal Blood Physiology and Biochemistry (book) was not cited in the article. The citation has now been inserted in Tables 2, 3, [Historical controls range] and should read:

TABLE 2
www.frontiersin.org

Table 2. Haematological values of rats in oxyclozanide-treated group and control group.

TABLE 3
www.frontiersin.org

Table 3. Liver function related to biochemical profiles.

“[Historical controls range (45)]”

45. Wang D, Zeng L, Shang S. Reference Manual of Laboratory Animal Blood Physiology and Biochemistry. Science Publishing (2011).

In the published article, there was an error in Table 2 as published. The units for the hematological parameters used in Table 2 were missing. The corrected Table 2 and its caption **Hematological values of rats in the oxyclozanide-treated group and the control group appear below.

In the published article, there was an error in Table 3 as published. The units for the biochemical parameters used in Table 3 were missing. The corrected Table 3 and its caption **Liver function related to biochemical profiles appear below.

In the published article, Supplementary Appendix 1 was mistakenly not included in the publication. The missing material appears below:

The blood samples collected in the EDTAK2-coated tubes were analyzed using Mindray BC-2800 Vet Automatic blood analyser (MINDRAY Medical International Co., Ltd). Erba XL-640 Automatic biochemical analyser (Erba Mannheim Co., Ltd.) was used for biochemical examination.

The authors apologize for this error and state that this does not change the scientific conclusions of the article in any way. The original article has been updated.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Keywords: oxyclozanide, acute, subacute, toxicity, rats

Citation: Wang W, Dong Z, Zhang J, Zhou X, Wei X, Cheng F, Li B and Zhang J (2023) Corrigendum: Acute and subacute toxicity assessment of oxyclozanide in Wistar rats. Front. Vet. Sci. 10:1130466. doi: 10.3389/fvets.2023.1130466

Received: 23 December 2022; Accepted: 13 January 2023;
Published: 01 February 2023.

Edited and reviewed by: Arturo Anadón, Complutense University of Madrid, Spain

Copyright © 2023 Wang, Dong, Zhang, Zhou, Wei, Cheng, Li and Zhang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Jiyu Zhang, yes aW5memp5JiN4MDAwNDA7c2luYS5jb20=

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.