Skip to main content

CASE REPORT article

Front. Vet. Sci., 14 July 2022
Sec. Veterinary Neurology and Neurosurgery
This article is part of the Research Topic Insights in Veterinary Neurology and Neurosurgery: 2022 View all 7 articles

Case Report: Clinical Use of a Patient-Individual Magnetic Resonance Imaging-Based Stereotactic Navigation Device for Brain Biopsies in Three Dogs

\nSarah Gutmann
Sarah Gutmann1*Thomas FlegelThomas Flegel1Marcel MüllerMarcel Müller2Robert MbiusRobert Möbius3Kaspar MatiasekKaspar Matiasek4Florian KnigFlorian König5Dirk WinklerDirk Winkler3Ronny GrunertRonny Grunert2
  • 1Department for Small Animals, Faculty of Veterinary Medicine, Leipzig University, Leipzig, Germany
  • 2Medical Engineering, Fraunhofer Institute for Machine Tools and Forming Technology, Dresden, Germany
  • 3Department for Neurosurgery, University Hospital Leipzig, Faculty of Medicine, Leipzig, Germany
  • 4Section of Clinical and Comparative Neuropathology, Ludwig-Maximilians-Universität, Munich, Germany
  • 5Small Animal Practice, Neurology, Wiesbaden, Germany

Three-dimensional (3D) printing techniques for patient-individual medicine has found its way into veterinary neurosurgery. Because of the high accuracy of 3D printed specific neurosurgical navigation devices, it seems to be a safe and reliable option to use patient-individual constructions for sampling brain tissue. Due to the complexity and vulnerability of the brain a particularly precise and safe procedure is required. In a recent cadaver study a better accuracy for the 3D printed MRI-based patient individual stereotactic brain biopsy device for dogs is determined compared to the accuracies of other biopsy systems which are currently used in veterinary medicine. This case report describes the clinical use of this 3D printed MRI-based patient individual brain biopsy device for brain sampling in three dogs. The system was characterized by a simple handling. Furthermore, it was an effective and reliable tool to gain diagnostic brain biopsy samples in dogs with no significant side effects.

Introduction

Three-dimensional (3D) printing technology has become an important tool for patient-individual medicine and so has found its way into veterinary neurosurgery in recent years. The technique of 3D printing, also known as additive manufacturing, is used to generate physical patient-individual models from digital files by applying a special material layer for layer (1). In veterinary neurosurgery, 3D printing is used to produce patient-individual anatomical models for surgical planning and education, to design specific neurosurgical devices for diagnostic and treatment purposes of the spine, like patient-specific drill guides for screw placement, and to develop implants for cranioplasty or vertebral fixation (214). In addition, 3D printing has been used for brain biopsy procedures in dogs (1518).

Due to the complexity and vulnerability of the brain, high accuracy and precision during brain biopsy procedures are needed. Those requirements are fulfilled by patient-specific 3D printed navigation devices, and therefore, those constructions are considered to be a safe and reliable option for sampling brain tissues. In a recent cadaver study, the accuracy of the 3D printed magnetic resonance imaging (MRI)-based patient-individual stereotactic brain biopsy frame used in the study presented here was determined (17). A total median target point deviation of 0.83 mm was achieved in that study, therefore reaching a better application accuracy than most brain biopsy systems currently used in veterinary medicine, which have mean needle placement errors ranging from 0.9 to 4.3 mm (1924) and median needle placement errors of 1.5 mm up to 2.8 mm in dogs (18, 25, 26).

This case report describes the clinical use of an MRI-based patient-individual stereotactic brain biopsy device for brain biopsy procedure in three dogs that have been described in detail elsewhere (16, 17). Intraoperative and postoperative complications, histopathological diagnoses, and neurological outcomes were reported.

Case Presentation

The first dog, which underwent a brain biopsy procedure with the patient-individual MRI-based stereotactic brain biopsy frame, was a 6-year-old male mixed breed dog. The MRI scan of the brain performed at the referring veterinarian revealed multifocal brain lesions within the cerebrum. Therefore, the dog was referred for a brain biopsy procedure in order to determine the underlying pathology. The second dog was an 8-year-old female boxer. The MRI examination of its brain revealed a mass lesion in the left frontal lobe. The third dog was a 5-year-old male malinois, in which the MRI of the brain showed a small T2-weighted (T2W) and fluid-attenuated inversion recovery (FLAIR) hyperintense lesion in the left ectomarginal gyrus (diameter 3 mm) with no contrast enhancement and bilaterally symmetrical T2W hyperintensities within the hippocampus and the piriforme lobe. All three dogs were presented to the local vet because of generalized tonic-clonic epileptic seizures. Table 1 summarizes the details of the neurological examination, initial MRI findings, further diagnostic tests and the medication prior to brain biopsy, the number of brain biopsy samples, the MRI findings immediately following the biopsy procedure, the days until discharge, the histopathological diagnoses, the MRI findings post brain biopsy, and the adjustments of treatments based on the histopathological diagnoses for all three dogs.

TABLE 1
www.frontiersin.org

Table 1. Results of neurological examination before the brain biopsy procedure, diagnostic tests including CSF analysis and MRI findings, medication prior to brain biopsy, the number of the biopsy samples taken, histopathological diagnoses, MRI findings post brain biopsy, complications, duration of hospitalization, and further treatment for each dog.

Before the brain biopsy procedure, all dogs received a planned MRI scan of the head for preparation of the patient-individual stereotactic brain biopsy frame. General anesthesia was induced with diazepam 0.5 mg/kg IV, butorphanol 0.38 mg/kg IV, and propofol as needed for intubation, and dogs were maintained on isoflurane inhalation in 100 % oxygen. The hair paramedian over the frontal sinus and on both sides of the zygomatic arches was clipped. After sterile preparation, 10 mm skin incisions were made and three special titanium bone anchors were drilled into the bony points (paramedian over the frontal sinus, both sides of the zygomatic arches) by using a hand drill. The bone anchors were small commercially available titanium self-cutting screws (diameter 2 mm, length 4 mm; WaypointTM, FHC, Bowdoin, USA) with an inner thread in the head of the bone anchors. The head of the bone anchors extended 4.5 mm over the bony surface. Afterward, special MRI markers were secured to the inner thread of the head of the bone anchors (Figure 1). These MRI markers were made of small plastic cylinders (diameter 15 mm, height 17.5 mm) that contained two round press fit vitamin D capsules (Dekristol 20.000 I.E., Mibe GmbH). The base of those cylinders was secured to the bone anchors by a screw that fits into the inner thread of the anchor. Following placement of bone anchors and attached MRI markers, a planned MRI scan of the head using a slice thickness of 1 mm was performed in sternal recumbency using a head coil with a 3-Tesla MRI (Ingenia, Philipps Healthcare, Hamburg, Germany). Whether a T1W or T2W sequence was used depended on the imaging characteristics of the intracranial lesion. After the MRI scan, the markers were unscrewed from the bone anchors and the skin incisions were closed covering the anchors with a single suture. The dogs were recovered from anesthesia and discharged with a neck collar until the biopsy procedure was performed a few days later. The neck collar was necessary to reduce the risk of loosening the bone anchors by scratching the head. For planning and construction of the biopsy device, the anticipated trajectories to the brain lesions were drawn into the planning MRI scans (case 1: trajectory into the brain lesion in the marginal gyrus of the left cerebrum, case 2: trajectory into the mass lesion of the left frontal lobe, case 3: trajectory into the lesion into the left ectomarginal gyrus). Care was taken to avoid penetration of blood vessels and important neurological structures. The entry point on the brain surface was chosen in the middle of the gyrus. The computer-aided construction and manufacturing of the biopsy devices were made by an engineer as previously described (16, 17). The 3D frames consisted of a biopsy port and three legs each resting on one bone anchor. All devices were made from polyamide material (PA12) by using Multi Jet Fusion (MJF) techniques of the company HP (Jet Fusion 3D 4200, Palo Alto, California, USA). The frames were sterilized with gas sterilization (formaldehyde 3%, 6 h by 60°C).

FIGURE 1
www.frontiersin.org

Figure 1. (A) Preparation of the patient for the planning MRI scan. Dog head (case 3) with the three bone anchors and specific MRI markers in place at both zygomatic arches and paramedian over the frontal sinus (red circles). (B) Dorsal T1W MR image of the planning MRI scan for dog 1 with the MRI markers in place (red circles). The MRI markers were made of small plastic that contained two round press fit vitamin D capsules, which were visible in the MR images. (C) The computer-aided construction of the patient-individual brain biopsy device on the basis of the MR images was made by an engineer. The biopsy frame consists of three legs and a biopsy port in prolongation to the biopsy trajectory to the target point in the intracranial lesion.

The biopsy procedure in cases 1 and 2 was performed 6 days after the planning procedure, whereas in case 3, the biopsy procedure was carried out 2 days after the planning MRI. For those procedures, the dogs received general anesthesia (induced with diazepam 0.5 mg/kg IV, fentanyl 5 μg/kg IV, and propofol as needed for intubation). It was maintained with isoflurane in 100% oxygen (dog 1) or propofol-CRI (dog 2 and 3, 0.2 mg/kg/min IV) in combination with fentanyl-CRI (at 5–12 μg/kg/h IV), cephazolin (30 mg/kg IV), and metamizole (40 mg/kg IV). The hair of the head was clipped between the following borders: craniocaudal: eyebrows to the neck and laterolateral: between both zygomatic arches. The sutures over the three bone anchors were removed and the heads were prepared aseptically. The three legs of the patient-individual 3D biopsy frames were rigidly attached to the bone anchors using three specific screws (Figure 2A). Then, minimally invasive access to the skull was created in the prolongation of the biopsy port. A skin incision of 20 mm was made and the temporal muscle was separated from the skull surface. After placing a drill sleeve into the tool guide of the biopsy port, a round craniotomy of 3 mm was drilled (Electric Pen Drive, DePuy Synthes, West Chester, Pennsylvania, USA) (Figure 2C). Because of the special position of the intracranial lesion in case 2 (left-sided rostral frontal lobe), the access to the brain was performed through the frontal sinus and a two-stage drilling process was needed in this case: A 3 mm mini burr hole into the left frontal sinus was made using the drill sleeve of the biopsy port; then, this small access was enlarged up to 15 mm in diameter to recognize possible bleeding in the depth, and later, the thin bony lamella overlaying the frontal lobe was perforated with a 3 mm drill using the drill sleeve of the biopsy port as well.

FIGURE 2
www.frontiersin.org

Figure 2. A brain biopsy procedure with the MRI-based patient-individual brain biopsy device. (A) A 3D printed biopsy frame (consisting of three legs and a biopsy port) attached to the bone anchors by using specific screws. (B) Patient-individual 3D printed measuring instrument for adjustment of the desired depth of the brain biopsy needle with help of a spacer. (C) A biopsy frame with the drill sleeve in place during the creation of a 3 mm mini burr hole for brain biopsy. (D) A brain biopsy needle placed in needle sleeve with an attached syringe.

As the next step, the dura mater was penetrated in all dogs with a 0.3 mm hypodermic needle. The drill sleeve was then removed and the biopsy sleeve was placed into the tool guide of the biopsy port. A Sedan side-cutting brain biopsy needle with an outer diameter of 2.5 mm was used (ELEKTA, Stockholm, Sweden). The desired depth of the biopsy needle was adjusted with the help of the patient individual 3D printed measuring instruments made of the same material as the biopsy device (Figure 2B). Afterward, the biopsy needle was advanced through the needle sleeve of the tool guide into the brain parenchyma to the planned target point. Two (case 2 and 3) to three (case 1) brain biopsy samples were taken using an aspiration method by attaching a 3-ml syringe to the top of the biopsy needle (Figure 2D). The needle was placed into the intracranial lesion with a closed sampling opening at the tip. When the needle reached its pre-planned depth, the needle sampling area was opened by rotating the internal needle part. Brain tissue adjacent to the biopsy needle was aspirated into the opening by a negative pressure generated by retracting the plunger of the syringe to the 0.5 ml point. Then, the biopsy needle was closed again by rotating the inner part of the needle back into the original position and the brain tissue was cut off. The needle was removed from the skull with a closed side opening. The brain biopsy was flushed out of the biopsy needle into an embedding cassette for biopsies using physiological saline. The cassette was marked with the number of consecutive samples and then fixed in 10% buffered formalin. The direction of the side opening of the biopsy needle was slightly changed between the consecutive biopsies.

After the brain biopsy procedure, the 3D biopsy frame, as well as the bone anchors, were removed and the craniotomy opening was closed with bone wax. Then, the overlying tissue was closed into three layers. In dog 2, the burr hole in the bone overlying the frontal lobe was closed with bone wax and the outer craniotomy was closed using a titanium reconstruction mesh (20 by 30 mm in size) and three small titanium screws. The skin over the three bony points was closed with a single suture.

All dogs received a control MRI examination of the head immediately following the brain biopsy (case 1 and 2: Figure 3), where a T2W hypointense biopsy trajectory could be visualized. The dogs were monitored in the intensive care unit for 24 h and were treated with antiseizure medication (see Table 1), cephazolin (30 mg/kg TID IV), and analgesia (dog 1: butorphanol-CRI (0.1–0.3 mg/kg/h IV; dog 2 and 3: levomethadone 0.25 mg/kg QID SC and robenacoxib 2 mg/kg SID SC).

FIGURE 3
www.frontiersin.org

Figure 3. Transverse T2W MRI images of the hyperintense intracranial lesions (red circles) of the dogs in cases 1 and 2 before (A,C) and after the brain biopsy procedure (B,D). T2W hypointense artifacts along the biopsy trajectories (white arrows, presumptive air) leading into the brain lesion of cases 1 (B) and 2 (D).

In cases 1 and 2, no complication was noticed during or immediately following the biopsy. There was no neurological deterioration and therefore both dogs were discharged 48 h after the procedure on antiseizure and antibiotic medications (cephalexin 28 mg/kg BID PO for 5 days). In case 3, the surgeon experienced difficulties advancing the tip of the biopsy needle into the brain. The needle could not be inserted due to a resistance caused by an incomplete incision of the dura mater. Following an extension of the incision into the dura mater, the biopsy needle could be placed without further resistance. Dog 3 showed a deterioration of the neurological status and was not able to walk unassisted 1 day after brain biopsy. This non-ambulatory tetraparesis improved over the next 4 days, so the dog was discharged 6 days after the brain biopsy procedure with an ambulatory tetraparesis similar to the status prior to the brain biopsy.

Upon complete fixation, brain samples were routine processed (27). Histopathological analysis followed standard algorithms. In dog 1 the examination of the brain biopsy sample/ biopsy revealed a low-grade neuroglial tumor (glioma) of undefined cellular origin (28), the growth pattern of which on histology and MRI with lesions in the right piriforme lobe, the left parietal lobe, and right occipital lobe was consistent with that of the gliomatosis cerebri histotype (29, 30) (Figures 3A,B, 4). Therefore, in addition to the antiseizure medication (phenobarbital 3.7 mg/kg BID, levetiracetam 37 mg/kg TID, pregabalin 3.1 mg/kg TID), chemotherapy using lomustine (90 mg/m2 every 4 weeks) and radiation therapy (10 × 3 Gy, whole brain) were initiated. 1 year later, the dog was presented for a follow-up MRI examination of the brain, where regression of all lesions was visible. The dog was in good general health and had a stable neurologic status. However, the dog had to be euthanized nearly 1.5 years after the brain biopsy procedure because of renal failure potentially caused by lomustine treatment.

FIGURE 4
www.frontiersin.org

Figure 4. Histopathological images of case 1: Diffuse low-grade spindeloid glioma with sparing of gray matter (A), perineural (B), and perivascular (C) structures of Scherer. The cells present with moderate cellular atypia, ovoid to elongated nuclei, stippled chromatin, unremarkable nucleoli, and invisible cell borders. Mitoses are not seen. The cells stained negative for GFAP, MAP2, and OLIG2.

In dog 2, the histopathological examination identified high-grade (anaplastic) oligodendroglioma (28), in which former WHO recommendations suggested grade 3 behavior (29). The dog was treated with lomustine (80 mg/m2 every 4 weeks) in combination with an antiseizure medication using phenobarbital (3.2 mg/kg TID), levetiracetam (48 mg/kg TID), and potassium bromide (21 mg/kg BID). It was euthanized 11 months after the brain biopsy procedure because of adverse effects due to the chemotherapy.

The histopathological investigation of the brain biopsy samples in dog 3 showed a mild lymphocytic presumptive immune-mediated encephalitis after exclusion of common infectious agents. The dog was treated with antiseizure medication (phenobarbital 4.4 mg/kg TID, potassium bromide 21 mg/kg TID, topiramate 5.9 mg/kg TID, pregabalin 2.2 mg/kg TID) and an immunosuppressive therapy using azathioprine (initially 2 mg/kg SID, followed by the same dose EOD after the first 2 weeks). Those medications did result in significant improvement of the neurological status and reduction in seizure frequency from severe cluster seizures every 2 weeks to three cluster seizures within 6 months. At the time of writing the manuscript, the dog was still alive 6 months after the brain biopsy procedure.

Discussion

This case report described the clinical use of an MRI-based 3D printed patient-individual stereotactic brain biopsy device. Two of three dogs were diagnosed with specific neoplastic diseases based on histopathological examination of the brain biopsy specimen. In one of those two dogs, the presumptive diagnosis based on MRI examination was an inflammatory disease because of the multifocal distribution pattern. In this case, the diagnosis significantly altered the treatment plan. Therefore, this case report underlines the importance of sampling intracranial lesions for specific histopathological diagnoses. Neither CSF analysis nor brain MRI can reliably differentiate between inflammatory and neoplastic brain disease in veterinary medicine (3136). Therefore, brain biopsy represents a helpful tool for obtaining specific diagnoses of intracranial lesions.

In both dogs with neoplastic disease, the therapy (chemotherapy with or without radiation) led to an improvement of the dogs' neurological signs for 1 to 1.5 years. The sampling of the lesion of the third dog revealed presumptive immune-mediated encephalitis. The dog showed a significant improvement in immunosuppressive treatment. Due to the small case series, it is not possible to determine a diagnostic yield of the biopsy procedure. In previous literature, the diagnostic yield of other brain biopsy devices was reported to range from 73.9 to 96.4% (15, 2527, 3742).

While the study was being conducted, two of the three dogs presented in this case report were already euthanized. Unfortunately, the owners refused a histopathological examination of the dogs' brain postmortem, which is why it is not possible to give a statement on the diagnostic accuracy of the brain biopsy procedure. The diagnostic accuracy indicates whether the histopathological diagnosis determined by brain biopsy is consistent with the results of histopathological examination of the brain postmortem or after partial surgical tumor resection. Few previous studies determined the diagnostic accuracy for brain biopsies, which varied between 81 and 100% (26, 37, 40, 41).

Although diagnostic tissue samples were taken from the brain, they may not necessarily be representative of the primary pathology. Peritumoral inflammation adjacent to a neoplastic lesion or a necrotic area within the neoplastic lesion may have been sampled inadvertently (25). Hence, care must be taken during planning the target point for the stereotactic brain biopsy procedure to avoid such regions. Therefore, the MRI signal behavior of different areas of a lesion, primary vs. secondary changes, should be critically considered.

Dog 1 exhibited temporary bradycardia at the beginning of the anesthesia, which disappeared again without further treatment. Sedation with anesthesia in cases 2 and 3 was uneventful. Two of the three dogs (case 1 and 2) showed no major intraoperative or postoperative complications and no neurological deterioration following the biopsy. Therefore, those dogs could be discharged 48 h after the procedure. The other dog (case 3) showed a temporary worsening of the preexisting tetraparesis and was not able to walk for 4 days following the brain biopsy. This deterioration seems to be associated with a problem experienced by the surgeon during the placement of the biopsy needle, which was probably caused by an incomplete dura mater penetration. The brain may have been intermittently compressed by unsuccessful attempts of needle insertion. The previously reported brain biopsy associated morbidity in dogs ranges from 27 to 30% and mortality rates are reported to be 5.2 to 20% in veterinary literature (25, 27, 3739, 43).

There are only two other studies describing brain biopsy procedures with the use of 3D printed devices. In one, a 3D printed facemask for brain sampling was used, resulting in specific histopathological diagnoses in four out of five dogs (15). Although no information about the application accuracy of the system is given, it can be assumed that the use of facemasks for brain biopsies is less accurate than the system used here, because the bridge of the nose and the nasal planum were used for the construction of the device, which appears to be problematic, especially in brachycephalic dog breeds. In addition, the face mask cannot be completely rigidly secured to the skull. In the case report presented here, the patient-individual 3D printed frame was rigidly fixed to the skull by using three bone anchors and specific screws, this most likely led to a higher accuracy during brain sampling compared to the use of noninvasive facemasks.

Another study describes the accuracy of a patient-individual 3D printed brain biopsy frame and the use of this system for sampling the brain in two client-owned dogs (18). With that system, one of two dogs could be sampled successfully. One of the disadvantages of this device is that the frame cannot be used with minimal-invasive access because the device is secured directly to the skull surface. A median needle placement error of 2.7 mm (range: 0.86–4.5 mm) is reported (18). The accuracy of the system presented here is determined in a cadaver study with a median target point deviation of 0.83 mm (range: 0.09–2.76 mm; 17). Furthermore, the technique was minimally invasive and all dogs could be sampled successfully in this case report.

The advantages of the patient-individual 3D-printed frames used in the case series presented here are relatively high safety and simple handling, which lead to successful brain biopsy procedures and high accuracy even in deep seeded lesions (16, 17). The frame-based brain biopsy procedure was a relatively short surgical intervention of about 45–60 min. The system can be used in dogs with every size and shape of the skull, because of the patient-individual design. Some other brain biopsy systems have limitations in their use with regard to different skull sizes or shapes, especially in brachycephalic dogs (15, 19, 21). The frame presented in this case report was designed based on MR images only, that is why a computer tomography (CT) scan of the skull was not needed. However, in cases of CT visible intracranial lesions, the same system can be used based on CT images only, because the markers are visible in both imaging modalities. Another advantage of the system presented here is the possibility to sample multiple brain regions in the procedure. The frame can be designed with multiple biopsy ports to sample different lesions in patients with multifocal intracranial disease. Furthermore, in the case of large brain lesions, multiple samples of different areas of the same lesion can be obtained by sampling different depths of the lesion along one trajectory. In the two cases with multifocal lesions (case 1 and 3), just one lesion was sampled. The authors chose the most superficial and easily accessible lesion for planning the biopsy trajectory. In fact, care should be taken to keep the path to the target region short, but care must be taken to ensure that no important neurological structures, blood vessels, or ventricles are penetrated. In this case, a slightly longer path through the brain tissue may be preferable to the shorter path. In order to avoid non-specific findings due to postictal changes, asymmetric lesions would be preferred to symmetrical lesions for sampling. In the future, we recommend the authors to use multiple biopsy ports in cases of multifocal brain lesions if they are accessible. However, care must be taken, because, in human medicine, it is known that an increasing number of brain specimens and multiple biopsy trajectories increase the risk for adverse effects (44, 45).

Another advantage is that the system is less expensive than other rigid stereotactic brain biopsy frames or modern neuronavigation systems.

A major disadvantage of the system was the need to separate the biopsy procedure into two parts, the planning and the actual biopsy, with a few days elapsing between both. Therefore, two general anesthesia were needed. More importantly, the time delay bore the risk of anchor loosening, which made the biopsy procedure using the patient-individual device impossible. This complication was experienced in a fourth dog (dog 0), where another biopsy system had to be used for brain sampling. From that time on, a collar was applied to all dogs between the two procedures in order to prevent scratching or rubbing the dog's head potentially resulting in anchor loosening. Furthermore, anchor loosening had been prevented from that time on. It appears to be crucial to use screws with a large screw head base maximizing the screw bone interface in order to reduce the risk of loosening during the waiting period between screw placement and biopsy procedure since the screws are placed into prominent bony points that are exposed to external forces.

Another disadvantage of the two-step system described here is that patients with a presumably inflammatory intracranial lesion can often not be deprived of anti-inflammatory medication while waiting for the biopsy procedure, whereas using such medication may alter histopathological findings. Therefore, we have adjusted the workflow of designing and printing the biopsy device, resulting in a reduction of the time span between planning and taking the biopsy to 2 days.

The lack of flexibility is another general disadvantage of frame-based stereotactic brain biopsy systems compared to other neuronavigation systems (23, 26, 27), especially when using 3D printed frames, where the target trajectory can no longer be changed. Nevertheless, the information from a well-planned brain biopsy is essential to gain a specific diagnosis and initiate purposeful therapy.

In conclusion, the MRI-based patient-individual 3D printed stereotactic brain biopsy device had simple handling and was an effective and reliable tool to gain diagnostic brain biopsy samples in three dogs.

Data Availability Statement

The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author/s.

Ethics Statement

Ethical review and approval was not required for the animal study because the study was performed in agreement with the local ethical regulations. All owners of the dogs agreed to the sampling of their dog's brain with the new system and confirmed in writing that the results may be published afterwards. Written informed consent was obtained from the owners for the participation of their animals in this study.

Author Contributions

SG: acquisition of data, analysis and interpretation of data, and writing the manuscript. TF: conception and design of the study, acquisition of data, and critical revising of the manuscript. MM: conception and design of the biopsy frames and proofreading. RM: 3D print of the biopsy frames, analysis of data, and proofreading. KM: acquisition of data (neuropathology). FK: acquisition of data and proofreading. DW and RG: conception and design of the study and proofreading. All authors contributed to the article and approved the submitted version.

Funding

This study was supported by a research fund from the GKF (Gesellschaft zur Förderung kynologischer Forschung), project number: 25310896.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Randazzo M, Pisapia JM, Singh N, Thawani JP. 3D printing in neurosurgery: a systematic review. Surg Neurol Int. (2016) 7:801–9. doi: 10.4103/2152-7806.194059

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Altwal J, Wilson CH, Griffon DJ. Applications of 3-dimensional printing in small-animal surgery: a review of current practices. Vet Surg. (2021) 44:1–18. doi: 10.1111/vsu.13739

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Oxley B, Behr S. Stabilisation of a cranial cervical vertebral fracture using a 3D –printed patient-specific drill guide. J Small Anim Pract. (2016) 57:277. doi: 10.1111/jsap.12469

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Hamilton-Bennett SE, Oxley B, Behr S. Accuracy of a patient-specific 3D printed drill guide for placement of cervical transpedicular screws. Vet Surg. (2018) 47:236–42. doi: 10.1111/vsu.12734

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Mathiesen CB., de la Puerta B, Groth AM, Rutherford S, Cappello R. Ventral stabilization of thoracic kyphosis through bilateral intercostal thoracotomies using SOP (String of Pearls) plates contoured after a 3-dimensional print of the spine. Vet Surg. (2018) 00:1–9. doi: 10.1111/vsu.12939

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Elford JH, Oxley B, Behr S. Accuracy of placement of pedicle screws in the thoracolumbar spine of dogs with spinal deformities with three-dimensionally printed patient-specific drill guides. Vet Surg. (2019) 49:1–7. doi: 10.1111/vsu.13333

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Fujioka T, Nakata K, Nishida H, Sugawara T, Konno N, Maeda S, et al. A novel patient-specific drill guide template for stabilization of thoracolumbar vertebrae of dogs: cadaveric study and clinical cases. Vet Surg. (2019) 48:336–42. doi: 10.1111/vsu.13140

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Joffe MR, Parr WCH, Tan C, Walsh WR, Brunel L. Development of a customized interbody fusion device for treatment of canine disc-associated cervical spondylomyelopathy. Vet Comp Orthop Traumatol. (2019) 32:79–86. doi: 10.1055/s-0038-1676075

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Kamishina H, Sugawara T, Nakata K, Nishida H, Yada N, Fujioka T, et al. Clinical application of 3D printing technology to the surgical treatment of atlantoaxial subluxation in small breed dogs. PLoS ONE. (2019) 14:1–18. doi: 10.1371/journal.pone.0216445

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Suñol A, Aige V, Morales C, López-Beltran M, Feliu-Pascual AL, Puig J. Use of three-dimensional printing models for veterinary medical education: impact on learning how to identify canine vertebral fractures. J Vet Med Educ. (2019) 46:523–32. doi: 10.3138/jvme.0817-109r

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Fuijoka T, Nakata K, Nakano Y, Nozue Y, Sugawara T, Konno N, et al. Accuracy and efficacy of a patient-specific drill guide template system for lumbosacral junction fixation in medium and small dogs: cadaveric study and clinical cases. Front Vet Sci. (2020) 6:494. doi: 10.3389/fvets.2019.00494

PubMed Abstract | CrossRef Full Text | Google Scholar

12. James J, Oblak ML. zur Linden AR, James FMK, Phillips J, Parkes M. Schedule feasibility and workflow for additive manufacturing of titanium plates for cranioplasty in canine skull tumors. BMC Vet Res. (2020) 16:180. doi: 10.1186/s12917-020-02343-1

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Toni C, Oxley B, Behr S. Atlanto-axial ventral stabilisation using 3D-printed patient-specific drill guides for placement of bicortical screws in dogs. J Small Anim Pract. (2020) 61:1–8. doi: 10.1111/jsap.13188

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Toni C, Oxley B, Clarke S, Behr S. Accuracy of placement of pedicle screws in the lumbosacral region of dogs using 3D-printed patient-specific drill guides. Vet Comp Orthop Traumatol. (2020) 34:53–8. doi: 10.1055/s-0040-1716840

PubMed Abstract | CrossRef Full Text | Google Scholar

15. James MD, Bova FJ, Rajon DA, Carrera-Justiz S, Clemmons RM, Novel MRI, CT compatible stereotactic brain biopsy system in dogs using patient-specific facemasks. J Small Anim Pract. (2017) 58:615–21. doi: 10.1111/jsap.12705

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Müller M, Winkler D, Möbius R, Sauerstein T, Scholz S, Gutmann S, et al. A concept for a 3D-printed patient-specific stereotaxy platform for brain biopsy - a canine cadaver study-. Res Vet Sci. (2019) 124:79–84. doi: 10.1016/j.rvsc.2019.02.007

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Gutmann S, Winkler D, Müller M, Möbius R, Fischer JP, Böttcher P, et al. Accuracy of a magnetic resonance imaging-based 3D printed stereotactic brain biopsy device in dogs. J Vet Intern Med. (2020) 34:844–51. doi: 10.1111/jvim.15739

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Shinn R, Park C, DeBose K, Hsu FC, Cecere T, Rossmeisl J. Feasibility and accuracy of 3D printed patient-specific skull contoured brain biopsy guides. Vet Surg. (2021) 50:1–11. doi: 10.1111/vsu.13641

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Koblik PD, LeCouteur RA, Higgins RJ, Fick J, Kortz GD, Sturges BK, et al. Modification and application of a Pelorus Mark III stereotactic system for CT-guided brain biopsy in 50 dogs. Vet Radiol Ultrasound. (1999) 40:424–33. doi: 10.1111/j.1740-8261.1999.tb00370.x

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Moissonnier P, Bordeau W, Delisle F, Devauchelle P. Accuracy testing of a new stereotactic CT-guided brain biopsy device in the dog. Res Vet Sci. (2000) 68:243–47. doi: 10.1053/rvsc.1999.0370

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Troxel MT, Vite CH. CT-guided stereotactic brain biopsy using the Kopf stereotactic system. Vet Radiol Ultrasound. (2008) 49:438–43. doi: 10.1111/j.1740-8261.2008.00403.x

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Chen AV, Wininger FA, Frey S, Comeau RM, Bagley RS, Tucker RL, et al. Description and validation of a magnetic resonance imaging-guided stereotactic brain biopsy device in the dog. Vet Radiol Ultrasound. (2012) 53:150–56. doi: 10.1111/j.1740-8261.2011.01889.x

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Taylor AR, Cohen ND, Fletcher S, Griffin JF, Levine JM. Application and machine accuracy of a new frameless computed tomography-guided stereotactic brain biopsy system in dogs. Vet Radiol Ultrasound. (2013) 54:332–42. doi: 10.1111/vru.12025

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Squires AD, Gao Y, Taylor SF, Kent M, Tsz Ho Tse Z. A simple and inexpensive stereotactic guidance frame for MRI-guided brain biopsy in canines. J Med Eng. (2014) 2014:139535. doi: 10.1155/2014/139535

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Rossmeisl JH, Andriani RT, Cecere TE, Lahmers K, LeRoith T, Zimmerman KL, et al. Frame-based stereotactic biopsy of canine brain masses: technique and clinical results in 26 cases. Front Vet Sci. (2015) 2:20. doi: 10.3389/fvets.2015.00020

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Meneses F, Maiolini A, Forterre F, Oevermann A, Schweizer-Gorgas D. Feasibility of a frameless brain biopsy system for companion animals using cone-beam CT-based automated registration. Front Vet Sci. (2022) 8:779845. doi: 10.3389/fvets.2021.779845

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Gutmann S, Tästensen C, Böttcher IC, Dietzel J, Loderstedt S, Kohl S, et al. Clinical use of a new frameless optical neuronavigation system für brain biopsies: 10 cases (2013 to 2020). J Small Anim Pract. (2022) 63:468–81. doi: 10.1111/jsap.13482

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Koehler JW, Miller AD, Miller CR, Porter B, Aldape K, Beck J, et al. A revised diagnostic classification of canine glioma: towards validation of the canine glioma patient as a naturally occurring preclinical model for human Glioma. J Neuropathol Exp Neurol. (2018) 77:1039–54. doi: 10.1093/jnen/nly085.PMID: 30239918

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Louis DN, Perry A, Reifenberger G, Von Deimling A, Figarella-Branger D, Cavenee WK, et al. The 2016 World Health Organization classification of tumors of the central nervous system: a summary. Acta Neuropathol. (2016) 131:803–20. doi: 10.1007/s00401-016-1545-1

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Koestner A, Bilzer T, Fatzer R. Histological classification of tumors of the nervous system of domestic animals. Washington, DC: Armed Forces Institute of Pathology (1999).

Google Scholar

31. Cervera V, Mai W, Vite CH, Johnson V, Dayrell-Hart B, Seiler GS. Comparative magnetic resonance imaging findings between gliomas and presumed cerebrovascular accidents in dogs. Vet Radiol Ultrasound. (2011) 52:33–40. doi: 10.1111/j.1740-8261.2010.01749.x

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Wisner ER, Dickinson PJ, Higgins RJ. Magnetic resonance imaging features of canine intracranial neoplasia. Vet Radiol Ultrasound. (2011) 52:52–61. doi: 10.1111/j.1740-8261.2010.01785.x

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Wolff CA, Holmes SP, Young BD, Chen AV, Kent M, Platt SR, et al. Magnetic resonance imaging for the differentiation of neoplastic, inflammatory, and cerebrovascular brain disease in dogs. J Vet Intern Med. (2012) 26:589–97. doi: 10.1111/j.1939-1676.2012.00899.x

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Young BD, Fosgate GT, Holmes SP, Wolff CA, Chen-Allen AV, Kent M, et al. Evaluation of standard magnetic resonance characteristics used to differentiate neoplastic, inflammatory, and vascular brain lesions in dogs. Vet Radiol Ultrasound. (2014) 55:399–406. doi: 10.1111/vru.12137

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Flegel T. Breed-specific magnetic resonance imaging characteristics of necrotizing encephalitis in dogs. Front Vet Sci. (2017) 4:203. doi: 10.3389/fvets.2017.00203

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Maclellan MJ, Ober CP, Feeney DA, Jessen CR. Evaluation of diffusion-weighted magnetic resonance imaging at 30 Tesla for differentiation between intracranial neoplastic and noninfectious inflammatory lesions in dogs. J Am Vet Med Assoc. (2019) 255:71–7. doi: 10.2460/javma.255.1.71

PubMed Abstract | CrossRef Full Text | Google Scholar

37. Koblik PD, LeCouteur RA, Higgins RJ, Bollen AW, Vernau KM, Kortz GD, et al. CT-guided brain biopsy using a modified Pelorus Mark III stereotactic system: experience with 50 dogs. Vet Radiol Ultrasound. (1999) 40:434–40. doi: 10.1111/j.1740-8261.1999.tb00371.x

PubMed Abstract | CrossRef Full Text | Google Scholar

38. Moissonnier P, Blot S, Devauchelle P, Delisle F, Beuvon F, Boulha L, et al. Stereotactic CT-guided brain biopsy in the dog. J Small Anim Pract. (2002) 43:115–23. doi: 10.1111/j.1748-5827.2002.tb00041.x

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Adamo PF, Lang AS. Frameless stereotactic CT-guided needle brain biopsy in dogs. Proceedings of the 23rd Annual ACVIM Forum June 1-4, Baltimore, USA Abstract 78. J Vet Intern Med. (2005) 19:420.

Google Scholar

40. Flegel T, Oevermann A, Oechtering G, Matiasek K. Diagnostic yield and adverse effects of MRI-guided free-hand brain biopsies through a mini-burr hole in dogs with encephalitis. J Vet Intern Med. (2012) 6:969–76. doi: 10.1111/j.1939-1676.2012.00961.x

PubMed Abstract | CrossRef Full Text | Google Scholar

41. Staudacher A, Oevermann A, Forterre F. Henke D, Gorgas D. Diagnostic yield and diagnostic accuracy of magnetic resonance imaging-guided frameless stereotactic brain biopsy in dogs and cats with intracranial disease Proceedings of the 28th Symposium ESVN-ECVN Sep 18-19, Amsterdam, Niederlande. J Vet Intern Med. (2015) 30:463. doi: 10.1111/jvim.13802

CrossRef Full Text | Google Scholar

42. Kani Y, Cecere TE, Lahmers K, LeRoith T, Zimmerman KL, Isom S, et al. Diagnostic accuracy of stereotactic brain biopsy for intracranial neoplasia in dogs: Comparison of biopsy, surgical resection, and necropsy specimens. J Vet Intern Med. (2019) 33:1–8. doi: 10.1111/jvim.15500

PubMed Abstract | CrossRef Full Text | Google Scholar

43. Shinn RL, Kani Y, Hsu FC, Rossmeisl JH. Risk factors for adverse events occurring after recovery from stereotactic brain biopsy in dogs with primary intracranial neoplasia. J Vet Intern Med. (2020) 4:1–8. doi: 10.1111/jvim.15885

PubMed Abstract | CrossRef Full Text | Google Scholar

44. McGirt MJ, Woodworth GF, Coon AL, Frazier JM, Amundson E, Garonzik I, et al. Independent predictors of morbidity after image-guided stereotactic brain biopsy: a risk assessment of 270 cases. J Neurosurg. (2005) 102:897–901. doi: 10.3171/jns.2005.102.5.0897

PubMed Abstract | CrossRef Full Text | Google Scholar

45. Mizobuchi Y, Nakajima K, Fujihara T, Matsuzaki K, Mure H, Nagahiro S, et al. The risk of haemorrhage in stereotactic biopsy for brain tumors. J Med Invest. (2019) 66:314–8. doi: 10.1038/jp.2014.244

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: canine, brain biopsy, 3D printing, veterinary neurosurgery, brain tumor, stereotaxy

Citation: Gutmann S, Flegel T, Müller M, Möbius R, Matiasek K, König F, Winkler D and Grunert R (2022) Case Report: Clinical Use of a Patient-Individual Magnetic Resonance Imaging-Based Stereotactic Navigation Device for Brain Biopsies in Three Dogs. Front. Vet. Sci. 9:876741. doi: 10.3389/fvets.2022.876741

Received: 15 February 2022; Accepted: 03 June 2022;
Published: 14 July 2022.

Edited by:

Daisuke Hasegawa, Nippon Veterinary and Life Science University, Japan

Reviewed by:

John Henry Rossmeisl, Virginia Tech, United States
Shinichi Kanazono, Veterinary Specialists and Emergency Center, Japan

Copyright © 2022 Gutmann, Flegel, Müller, Möbius, Matiasek, König, Winkler and Grunert. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Sarah Gutmann, sarah.gutmann@kleintierklinik.uni-leipzig.de

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.