AUTHOR=Cherno Barry , Alvarez Leilani , Lamb Kenneth E. , Canapp Sherman TITLE=The Stryker Regenkit PRP Kit Does Not Concentrate Canine Platelets JOURNAL=Frontiers in Veterinary Science VOLUME=7 YEAR=2020 URL=https://www.frontiersin.org/journals/veterinary-science/articles/10.3389/fvets.2020.555909 DOI=10.3389/fvets.2020.555909 ISSN=2297-1769 ABSTRACT=

Platelet Rich Plasma (PRP) works to recruit growth factors, anti-inflammatory mediators, and blood supply to an area that may not heal well under normal conditions (e.g., joints, tendons, ligaments). Previous research has demonstrated that various PRP systems create vastly different final products. The objective of this study was to evaluate the cellular composition of the final plasma product using the Stryker RegenKit system in dogs. A peripheral blood sample was obtained from ten healthy adult dogs and compared to the final plasma product. A standard CBC was performed prior to testing and an additional sample was processed according the manufacturing guidelines for obtaining PRP (10 ml total blood). Comparisons of mean platelet count, erythrocyte count, and leukocyte count were made between the peripheral blood sample and the final plasma product. Results showed that there was no significant difference in platelet count between the peripheral blood CBC and final PRP CBC (p = 0.349). There were significantly fewer erythrocytes and leukocytes in the final plasma product when compared with peripheral blood (p = < 0.0001, p = 0.0318, respectively). These results indicate that the Stryker Regenkit PRP Kit decreases leukocyte and erythrocyte concentrations but does not consistently change platelet concentrations in its final plasma product. This study, in combination with results from similar studies, may allow clinicians to better choose the appropriate PRP system to treat various musculoskeletal conditions in dogs.