AUTHOR=Lehmann Hendrik , Hindricks Esther , Hassdenteufel Esther Maria , Moritz Andreas , Bauer Natali TITLE=Prospective Comparative Quality Control Study of a Novel Gravity-Driven Hollow-Fiber Whole Blood Separation System for the Production of Canine Blood Products JOURNAL=Frontiers in Veterinary Science VOLUME=6 YEAR=2019 URL=https://www.frontiersin.org/journals/veterinary-science/articles/10.3389/fvets.2019.00149 DOI=10.3389/fvets.2019.00149 ISSN=2297-1769 ABSTRACT=
The aim of this prospective study was to compare quality of blood products produced either by a novel gravity-driven hollow-fiber separation system (HF) or by centrifugation (C). Whole blood was obtained from 31 healthy non-greyhound canine blood donors and separated into fresh frozen plasma and packed red blood cells using either HF or C in a university teaching hospital. Red blood cell (RBC) count, albumin and fibrinogen concentration, prothrombin time (PT), activated partial thromboplastin time (aPTT) and coagulation factor activity (FV, FVIII), von Willebrand Factor (vWF), and antithrombin activity were assessed. Plasma obtained with the HF showed a significantly higher median PT (9.4 vs. 7.9 s,