ORIGINAL RESEARCH article

Front. Surg., 03 May 2023
Sec. Visceral Surgery

Feasibility and safety of a self-developed sleeve for the endoscopic removal of refractory foreign body incarceration

\r\nGuangqiu Yu,&#x;Guangqiu Yu1,†Li Li,&#x;Li Li2,†Yirui ZhangYirui Zhang1Xiaohuan ZhongXiaohuan Zhong1Jing WangJing Wang1Ling JiangLing Jiang1Duanmin Hu
Duanmin Hu1*Weixia Zhou
\r\nWeixia Zhou1*
  • 1Department of Gastroenterology, The Second Affiliated Hospital of Soochow University, Suzhou, China
  • 2Department of Gastroenterology, The Third People's Hospital of Dalian, Dalian, China

Objective: This study aimed to assess the feasibility and safety of a novel self-designed sleeve for the endoscopic removal of a refractory incarcerated foreign body in the upper gastrointestinal tract (UGIT).

Methods: An interventional study was conducted between June and December 2022. A total of 60 patients who underwent an endoscopic removal of a refractory incarcerated foreign body from the UGIT were randomly allocated to the self-developed sleeve and the conventional transparent cap. The study evaluated and compared the operation time, successful removal rate, new injury length at the entrance of the esophagus, new injury length at the impaction site, visual field clarity, and postoperative complications between the two groups.

Results: The success rates of the two cohorts in the foreign body removal display no significant discrepancy (100% vs. 93%, P = 0.529). Nevertheless, the methodology of the novel overtube-assisted endoscopic foreign body removal has culminated in a significant reduction in the removal duration [40 (10, 50) min vs. 80 (10, 90) min, P = 0.01], reduction in esophageal entrance traumas [0 (0, 0) mm vs. 4.0 (0, 6) mm, P < 0.001], mitigation of injuries at the location of the foreign body incarceration [0 (0, 2) mm vs. 6.0 (3, 8) mm, P < 0.001], an enhanced visual field (P < 0.001), and a decrement in postoperative mucosal bleeding (23% vs. 67%, P < 0.001). The self-developed sleeve effectively negated the advantages of incarceration exclusion during removal.

Conclusion: The study findings support the feasibility and safety of the self-developed sleeve for the endoscopic removal of a refractory incarcerated foreign body in the UGIT, with advantages over the conventional transparent cap.

1. Introduction

The presence of a foreign body in the upper gastrointestinal tract (UGIT) is a frequent digestive tract emergency encountered in clinical settings. The majority of patients commonly present with new-onset chest pain, odynophagia, or the feeling of an esophageal foreign body sensation after meals (1). However, it can also result in complications such as perforation, bleeding, and other adverse effects (2, 3).

Researchers have reported an increased risk of laceration when the foreign body has a sharp edge and is similar in length to the esophageal inner diameter, which is approximately 22–26 mm (4). An esophageal foreign body firmly embedded in the wall is more likely to cause mucosal damage during the embedding and removal procedures. Improper or delayed treatment of refractory foreign body incarceration can lead to severe complications such as mediastinitis, aortoesophageal fistula, pneumothorax, and pericardial effusion (58).

The outer sleeve is one of the most frequently implemented endoscopic tools for diagnosis and treatment, with its primary function being to safeguard the mucosa and reduce any associated damage (9). The outer sleeve currently implemented in clinical settings has an inner diameter of 14–21 mm, making it challenging to maneuver and extract larger-sized foreign bodies. The identification of the optimal method for the safe and effective removal of large and sharp foreign bodies firmly embedded in the gastrointestinal tract is a challenging aspect of emergency endoscopic treatment.

The tip of our independently developed endoscopic sleeve has been found to facilitate the removal of foreign body impactions, with an inner diameter of 18 mm and an outer diameter of 19 mm. The remotely inclined plane diameter measures 25 mm, which corresponds with the width that the esophagus can accommodate, allowing for the retrieval of all foreign bodies present within the esophagus.

In this study, we evaluated the efficiency and safety of a novel endoscopic foreign body removal sleeve (the self-developed sleeve) independently designed by our team to facilitate the acute management of refractory foreign body incarceration in the UGIT. To achieve this, we analyzed the clinical data of patients who underwent a soft gastroscopic removal of refractory foreign body incarceration in the UGIT at our hospital.

2. Materials and methods

2.1. Study design

This was an observational interventional study. We examined the difference between different auxiliary methods (the self-developed sleeve vs. transparent cap group) in terms of the operation time, removal success rate, new injury length at esophagus entrance, new injury length at foreign body entrapment, visual field clarity, and postoperative complications. The self-developed sleeve used in this research is a patent invented by the author, with patent number ZL 2020 2 2283346.0.

2.2. Patients

Patients who underwent an endoscopic treatment in our hospital due to refractory foreign body incarceration in the UGIT between June and December 2022 were observed.

(1) Inclusion criteria: adult patients with UGIT foreign bodies discovered by computed tomography (CT) and treated endoscopically; CT-estimated foreign body length ≥ 15 mm; foreign body embedded in the esophageal wall observed endoscopically; and postoperative follow-up of clinical symptoms via laboratory examination or CT showing whether there were complications.

(2) Exclusion criteria: patient age <18 years; CT-confirmed perforation of the digestive tract; or incomplete follow-up data.

Prior to participation, all patients underwent informed consent procedures. Approval for this study was obtained from the ethics committee of The Second Affiliated Hospital of Soochow University (no. jd-lk-2021-068-01), and the study was registered with the China Clinical Trial Registration Center (no. ChiCTR2200063289).

2.3. Equipment and procedures

Every patient underwent a preoperative CT scan to identify the exact location of the foreign object and its relation to surrounding organs. Prior to the procedure, the patients received either local anesthesia with 2% lidocaine and sedation or general anesthesia with propofol administered via the pharynx. A highly experienced gastroenterologist conducted the examination using an Olympus GIF-HQ290/H260 endoscope system (Olympus Optical Corporation, Tokyo, Japan) with a transparent cap of 12.4 mm inner diameter (D-201-11804; Olympus Optical Corporation), in accordance with the highest professional standards.

The design of the self-developed sleeve incorporated a soft, lubricated outer sleeve (with an inner diameter of 18 mm, outer diameter of 19 mm, distal slope length of 25 mm, tube wall thickness of 1.0 mm, and length options of 18, 28, or 50 cm) inserted into the gastroscope to reach the foreign object under gastroscopic visualization. The distal tip of the sleeve, equipped with a lens body, exerts pressure on the esophageal tube wall, allowing it to approach the deeply embedded tip of the foreign object. The foreign object is then removed with the aid of an auxiliary instrument rat tooth forceps. Figure 1 is a schematic diagram.

FIGURE 1
www.frontiersin.org

Figure 1. A foreign object impaction (A), and the extraction of the foreign object using the novel sheath (B). During the extraction, the distal tip of the sheath was employed to apply pressure on the esophageal wall with the lens body, affording the capability to precisely guide the tip of the sheath toward the foreign body. Once the target was in view, the foreign object was efficiently extracted using rat tooth forceps as the auxiliary instrument.

When the foreign object can be fully retracted into the outer sleeve, it will be removed with the gastroscope, while the sleeve remains in place to initiate hemostasis. The transparent tube wall facilitates observation of the extent of the damage before the outer sleeve is safely removed. In cases where the maximum transverse diameter of the foreign object is over 2.5 cm (excluding its length), the tip is drawn into the cannula before removal, and the foreign body is then pulled out with the gastroscope. Subsequently, the scope is re-inserted to evaluate a potential mucosal damage.

2.4. Data collection

Two experts in digestive endoscopy evaluated all study data. In cases of discrepancies, a third endoscopy expert was consulted for a final evaluation.

Data, including each patient's clinical information, foreign object location (cervical, thoracic, or abdominal esophageal segment), foreign object size, operation duration (from endoscope insertion to foreign object removal), the success rate of removal, and the length of additional mucosal damage at the entrance of the esophagus and at the site of foreign object embedding (using rat tooth forceps), were assessed.

Visual field definition was classified as follows: grade A referred to the observation of the foreign object shape, position, and esophageal mucosa; grade B referred to the observation of the foreign object shape, position, and some esophageal mucosa; and grade C indicated the nonobservance of the foreign object due to esophageal contraction, deep embedding, bleeding, or other circumstances, as well as potential complications such as mucosal damage, bleeding, perforation, and infection (10).

2.5. Statistical analysis

The statistical analysis was conducted using SPSS 23.0 software. Normally distributed measurement data were presented as X ± s, and intergroup comparisons were performed using a t-test. Skewed measurement data were expressed as M (Q1, Q3), and the non-parametric Mann–Whitney method was used for intergroup comparisons. Numerical data were reported as the number of cases, and the chi-squared test or Fisher's exact probability method was used for intergroup comparisons. A significance level of P <0.05 was utilized to determine statistical significance.

3. Results

The study included a total of 60 cases, with each group consisting of 30 cases. Table 1 lists the types of foreign objects, while Table 2 displays baseline characteristics of the two groups.

TABLE 1
www.frontiersin.org

Table 1. Foreign body types of the two groups.

TABLE 2
www.frontiersin.org

Table 2. Baseline characteristics of the two groups.

Compared to the transparent cap, the self-developed sleeve method effectively safeguards the mucosa at the entrance of the esophagus, reducing further mucosal damage after the removal of the foreign object. This not only ensures a clearer visual field but also shortens the operation duration and lessens the prevalence of intra- and postoperative complications during the removal of embedded foreign objects (Table 3). The self-developed sleeve method demonstrated a success rate of 100%, while that of the transparent cap method was 94%.

TABLE 3
www.frontiersin.org

Table 3. Comparison of outcomes between the two groups.

Removing foreign objects using the transparent cap group can be arduous and can lead to forceful extraction, thereby causing new injuries at the site of incarceration and at the entrance of the esophagus (Figure 2). Therefore, an independent development of a foreign object removal sleeve was created (Figure 1). The endoscope's distance from the sleeve tip is around 0.4 cm (0.2 cm invisible + 0.2 cm visible). Using the pressure applied to the endoscope's end, the incarceration is directly removed, causing the tip of the foreign object to enter and be removed through the sleeve or pulled into the sleeve using a foreign object clamp. The incarceration site is free from new damage, and the sleeve is delicately removed from the body, protecting the food inlet from scratches. In addition, the sleeve allows for compression hemostasis and a clear observation of the depth of the injury through transparent tubes.

FIGURE 2
www.frontiersin.org

Figure 2. When foreign objects are extracted from the conventional clear cap, an injury to the mucosal lining of the esophagus may occur, including scratching and bleeding. When foreign objects larger than the diameter of the clear cap are extracted, as shown in (A), it may cause scratching and bleeding at the esophageal inlet as indicated by the yellow arrow. In (B), the impaction of larger foreign bodies may not be resolved during removal, leading to scratching and bleeding of the impacted site due to the abrupt pulling of the foreign object. In addition, (C) depicts how the irregular removal of foreign objects can lead to scratching and bleeding.

The visual capacity of the transparent cap group is inadequate, making it challenging to visualize the incarcerated tip and remove it entirely. The manipulation process often damages the incarceration further. In addition, if the width of the foreign object exceeds the protective scope of the transparent cap, it can scratch the narrow entrance, subsequently causing additional damage (Figure 2). One participant assigned to the transparent cap group required an alternative method and was provided with a self-developed sleeve. After conducting a meticulous evaluation, we found that the patient depicted in Figure 3 was not a suitable candidate for using a transparent cap to remove foreign objects. Thus, during the surgical procedure, we employed a self-developed sleeve as an alternative method (Figure 4).

FIGURE 3
www.frontiersin.org

Figure 3. The transparent cap group revealed that (A) one end of the foreign body was wedged into the esophageal wall and could not be released and extracted by the clear cap; consequently, it must be forcibly removed, leading to a significant and unavoidable additional mucosal damage. Similarly, in (B), the depth of impaction of the foreign body on the other side remains obscured, precluding its release and extraction.

FIGURE 4
www.frontiersin.org

Figure 4. The same foreign body seen in Figure 3, which was removed using the self-developed sleeve. The sheath was used to press on one end of the foreign body, releasing it from entrapment as shown in (A). The sharp tip of the foreign body was then inserted into the self-developed sleeve for a controlled removal as displayed in (B), preventing additional injury to the surrounding structures. Following foreign body extraction, no new wounds were identified in the area as demonstrated in (C). Finally, the successful removal of the foreign body was confirmed as shown in (D).

Figure 4 depicts the same foreign object as in Figure 3, with the sleeve's tip pressing against the incarceration while delicately extracting it, allowing the tip of the foreign object to move smoothly into the sleeve, where it is then carefully extracted with the long axis of the foreign body parallel to it that effectively protects it. The incarceration site remains free from new damages throughout the entire process. We have recorded a video to dynamically demonstrate the excellent functionality of the self-developed sleeve in safely and effectively extracting foreign objects. This video is included as Supplementary Material S1.

4. Discussion

Typically, about 80%–90% of foreign bodies in the UGIT are naturally expelled through digestion, while 10%–20% require removal under endoscopic guidance, with only 1% necessitating surgical intervention or involving complications. When foreign objects have sharp edges, emergency endoscopic surgery is recommended within 2–6 h (11). Refractory foreign objects are particularly difficult to diagnose and treat under emergency endoscopy. A detailed medical history helps guide the appropriate imaging modalities, and the urgency of therapeutic intervention is established accordingly (12, 13).

The overtube is a commonly used auxiliary device in endoscopy for removing sharp foreign bodies within the upper digestive tract (9). According to existing literature, there are various overtube types with an inner diameter of 14–21 mm and a length range of 23–135 cm (14). Nevertheless, clinical practice often reveals that foreign bodies are too large to be pulled into the overtube due to their limited inner diameter (15). In terms of incarceration removal, innovative external sleeve solutions have been suggested by some studies (16, 17), which propose the use of a balloon to expand the esophageal wall and loosen foreign objects.

However, when the foreign object is large, or its sharp edges get deeply embedded within the esophageal wall, balloon dilation may be ineffective in removing the incarceration and may harm surrounding organs in the process. In addition, balloon dilation cannot safeguard the esophageal entrance if the foreign object is incarcerated at the entrance, and the space available for balloon diastolic operation is often limited.

Our self-developed sleeve has an inner diameter of 18 mm and a slope length of 25 mm, similar to the diameter of the esophagus. Made of soft materials, the sleeve fits comfortably with the endoscope, therefore, causing no discomfort. It can remove foreign objects with a transverse measurement no larger than 2.5 cm (not accounting for length), encompassing nearly all foreign bodies that may embed within the esophagus.

The distal part of the sleeve is inclined, a design that enhances the clearance of sharp foreign objects partially embedded in the esophageal wall by pressing against the wall, unlike a flat distal end. In this study, two patients from the transparent cap group who had irretrievable deeply embedded foreign objects were successfully treated with the innovative sleeve.

In contrast to the transparent cap employed in this study, the self-developed sleeve offers advantages. It removes embedded foreign objects by applying pressure to the esophageal wall in order to prevent secondary damage caused by the dislodging of mucosa at the embedment.

As a result, the entrance to the esophagus remains intact, undergoing no tearing during the process of the foreign object removal. After the extraction of the foreign object, the external pressure of the outer sleeve is instrumental in preventing mucosal bleeding and ensuring a clear visual field for inspecting the wound's depth, thereby highlighting the safety advantages of the self-developed sleeves. Despite the similarities in terms of the success rate in foreign object removal in this study, differences could not be significantly established among the three tools because of the sample size and the expertise of the endoscopist.

The primary limitations of this study are as follows: first, it is a single-center study with a small sample size, and the validity of our findings remains to be established through multisite studies. Second, despite stringent quality control measures, uncontrollable confounding variables may have impacted the results of our experimental study.

In summary, we present a self-developed sleeve endoscopic-assisted device for foreign body removal in this study. This device is handy in the management of stubborn sharp foreign bodies embedded in the UGIT. The application of this self-developed sleeve reduces operative time. It minimizes mucosal damage during object embedding, protecting the entrance to the esophagus, thereby maintaining a clearer visual field and avoiding postoperative mucosal bleeding. This device offers both efficacy and safety advantages and holds significant potential for clinical use and dissemination.

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding authors.

Ethics statement

The studies involving human participants were reviewed and approved by the Second Affiliated Hospital of Soochow University. The patients/participants provided their written informed consent to participate in this study. Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article.

Author contributions

The research and development of the self-developed sleeve were carried out by GY and LL. The data recording was performed by each employee, while the idea and conception of the study was generated by DH and WZ. The statistical analysis was conducted by LJ, while XZ and JW were responsible for collecting and organizing the data. YZ was responsible for the composition of the manuscript. All authors contributed to the article and approved the submitted version.

Acknowledgments

The authors would like to express their gratitude to the staff of the investigative center and the unwavering support of the patients and their families.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fsurg.2023.1150004/full#supplementary-material.

References

1. Kim JE, Ryoo SM, Kim YJ, Lee JS, Ahn S, Seo DW, et al. Incidence and clinical features of esophageal perforation caused by ingested foreign body. Korean J Gastroenterol. (2015) 66:255–60. doi: 10.4166/kjg.2015.66.5.255

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Wang X, Su S, Chen Y, Wang Z, Li Y, Hou J, et al. The removal of foreign body ingestion in the upper gastrointestinal tract: a retrospective study of 1,182 adult cases. Ann Transl Med. (2021) 9:502. doi: 10.21037/atm-21-829

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Sugawa C, Ono H, Taleb M, Lucas CE. Endoscopic management of foreign bodies in the upper gastrointestinal tract: a review. World J Gastrointest Endosc. (2014) 6:475–81. doi: 10.4253/wjge.v6.i10.475

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Hong KH, Kim YJ, Kim JH, Chun SW, Kim HM, Cho JH. Risk factors for complications associated with upper gastrointestinal foreign bodies. World J Gastroenterol. (2015) 21:8125–31. doi: 10.3748/wjg.v21.i26.8125

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Pagano N, Dolci G, Buttitta F, De Matteis M, Lauro A, Solli P. Another use for EUS: removal of a transesophageal-migrated mediastinal foreign body. Dig Dis Sci. (2021) 66:983–7. doi: 10.1007/s10620-020-06769-3

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Gong H, Wei W, Huang Z, Hu Y, Liu XL, Hu Z. Endovascular stent-graft treatment for aortoesophageal fistula induced by an esophageal fishbone: two cases report. World J Clin Cases. (2022) 10:2206–15. doi: 10.12998/wjcc.v10.i7.2206

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Fashandi AZ, Boys JA, Yount KW, Buerlein RC, Shami VM, Ailawadi G, et al. Isolated hemorrhagic pericardial effusion after foreign body ingestion. Ann Thorac Surg. (2018) 106:e141–3. doi: 10.1016/j.athoracsur.2018.02.056

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Erdal U, Mehmet D, Turkay K, Mehmet IA, Ibrahim N, Hasan B. Esophagus perforation and myocardial penetration caused by swallowing of a foreign body leading to a misdiagnosis of acute coronary syndrome: a case report. J Med Case Rep. (2015) 9:57. doi: 10.1186/s13256-015-0532-9

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Ofosu A, Ramai D, Reddy M. Overtube-assisted foreign body removal: a review of endoscopic management and case illustration. Cureus. (2017) 9:e1730. doi: 10.7759/cureus.1730

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Fang R, Cao B, Zhang Q, Li P, Zhang ST. The role of a transparent cap in the endoscopic removal of foreign bodies in the esophagus: a propensity score-matched analysis. J Dig Dis. (2020) 21:20–8. doi: 10.1111/1751-2980.12833

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Birk M, Bauerfeind P, Deprez PH, Häfner M, Hartmann D, Hassan C, et al. Removal of foreign bodies in the upper gastrointestinal tract in adults: European Society of Gastrointestinal Endoscopy (ESGE) clinical guideline. Endoscopy. (2016) 48:489–96. doi: 10.1055/s-0042-100456

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Zhang X, Jiang Y, Fu T, Zhang X, Li N, Tu C. Esophageal foreign bodies in adults with different durations of time from ingestion to effective treatment. J Int Med Res. (2017) 45:1386–93. doi: 10.1177/0300060517706827

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Inayat F, Zafar F, Lodhi HT, Hayat M, Kashif Saleem HM, Afzal A, et al. Endoscopic removal of large sharp-edged foreign bodies in the gastrointestinal tract using an innovative modification of the overtube. Cureus. (2018) 10:e3264. doi: 10.7759/cureus.3264

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Tierney WM, Adler DG, Conway JD, Diehl DL, Farraye FA, Kantsevoy SV, et al. Overtube use in gastrointestinal endoscopy. Gastrointest Endosc. (2009) 70:828–34. doi: 10.1016/j.gie.2009.06.014

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Swaminath A, Lucas AL, Capiak K, Sethi A, Garcia-Carrasquillo R. A foreign body larger than the overtube diameter: a case of a large cow foot bone causing esophageal impaction. Gastroenterol Hepatol (N Y). (2010) 6:793–5. 21301633

PubMed Abstract | Google Scholar

16. Lee SW, Jeen YT, Chun HJ, Song CW, Um SH, Choi JH, et al. Endoscopic removal of sharp foreign bodies impacted in the esophagus. Endoscopy. (2001) 33:518–22. doi: 10.1055/s-2001-15090

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Wu W, Han Y, Kong D. A novel technique for endoscopic removal of foreign bodies using a balloon and transparent cap. Endoscopy. (2022) 54:E149–50. doi: 10.1055/a-1407-9895

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: self-developed sleeve, refractory foreign body incarceration, endoscopy, upper gastrointestinal tract (UGIT), esophagus

Citation: Yu G, Li L, Zhang Y, Zhong X, Wang J, Jiang L, Hu D and Zhou W (2023) Feasibility and safety of a self-developed sleeve for the endoscopic removal of refractory foreign body incarceration. Front. Surg. 10:1150004. doi: 10.3389/fsurg.2023.1150004

Received: 15 March 2023; Accepted: 11 April 2023;
Published: 3 May 2023.

Edited by:

Abdulzahra Hussain, Homerton University Hospital NHS Foundation Trust, United Kingdom

Reviewed by:

Ozlem Boybeyi, Hacettepe University, Turkey
Pavel Skok, Maribor University Medical Centre, Slovenia

© 2023 Yu, Li, Zhang, Zhong, Wang, Jiang, Hu and Zhou. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Weixia Zhou wangxm222222@sina.com Duanmin Hu huduanmin@163.com

These authors have contributed equally to this work and shared the first authorship

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.