Skip to main content

REVIEW article

Front. Surg., 04 May 2022
Sec. Otorhinolaryngology - Head and Neck Surgery
This article is part of the Research Topic Improving Voice Outcomes after Thyroid Surgery and Ultrasound-guided Ablation Procedures View all 17 articles

Improving Voice Outcomes after Thyroid Surgery and Ultrasound-Guided Ablation Procedures

\r\nPia Pace-AsciakPia Pace-Asciak1Jon O. RussellJon O. Russell2Ralph P. Tufano
\r\nRalph P. Tufano3*
  • 1Department of Otolaryngology – Head and Neck Surgery, University of Toronto, Toronto, Canada
  • 2Department of Otolaryngology – Head and Neck Surgery, Johns Hopkins University, Baltimore, Maryland, United States
  • 3Sarasota Memorial Health Care System Multidisciplinary Thyroid and Parathyroid Center, Sarasota, Florida, United States

The field of endocrine surgery has expanded from the traditional open neck approach to include remote access techniques as well as minimally invasive approaches for benign and malignant thyroid nodules. In experienced hands and with careful patient selection, each approach is considered safe, however complications can and do exist. Post-operative dysphonia can have serious consequences to the patient by affecting quality of life and ability to function at work and in daily life. Given the significance of post-procedural dysphonia, we review the surgical and non-surgical techniques for minimizing and treating recurrent laryngeal nerve injury that can be utilized with the traditional open neck approach, remote access thyroidectomy, or minimally invasive thermal ablation.

Introduction

Thyroid surgery has been performed for thousands of years and still remains one of the more common head and neck procedures (1). With the modernization of thyroid surgery, the mortality rate has significantly dropped to less than 1% compared to 40% when in 1850, the French Medical Society banned these operations (2). The open neck approach that Kocher fathered is still used today, while newer methods to address thyroid nodules have evolved to address specific shortcomings. Such methods involve accessing the thyroid remotely with an endoscope in order to avoid a neck incision, or by minimally invasive techniques such as thermal ablation to avoid removing the thyroid gland at all. Regardless of the surgical approach, complications still exist.

In the hands of an experienced and high volume thyroid surgeon, complication rates may vary by disease pathology. Intraoperative injury to the recurrent laryngeal nerve (RLN) is one of the dreaded complications that can occur with open surgical approaches and less commonly with thermal ablation. Symptoms of unilateral vocal cord paralysis may include hoarseness, choking, dysphagia, and dysphonia with unilateral vocal cord paralysis, or symptoms of airway obstruction and stridor with bilateral vocal cord paralysis (36). Changes in the quality of voice or swallowing can significantly diminish a patient’s ability to work, socialize and perform many activities of daily living, thus emphasizing the importance of careful handling of the RLN (7, 8).

For open neck approaches to the thyroid, approximately 1 in 10 patients experience temporary RLN injury after surgery, with longer lasting permanent voice problems in up to 1 in 25 (9). Other contributing factors which may lead to temporary dysphonia post-surgery include laryngeal irritation, edema or injury from intubation. Injury to the external branch of the superior laryngeal nerve can also impair a patient’s quality of life by reducing the pitch and projection of the voice (10). For thermal ablation, namely radiofrequency ablation (RFA), injury to the RLN can be temporary or less frequently permanent (1113). Voice changes are less frequently noted (0.94%, 21/2245) in benign nodules treated with RFA compared with recurrent thyroid cancer (7.95%, 14/176) (11). The overall complication rate in RFA treated primary benign nodules is 2.11% compared with 10.98% for malignant thyroid nodules (11).

In this paper, we review the surgical and nonsurgical techniques for minimizing and treating post-operative dysphonia caused by an open approach or remote access thyroidectomy as well as minimally invasive thermal ablation (namely radiofrequency ablation). In addition, we review how intraoperative electromyographic (EMG) changes correlate to post-operative voice changes, and how to treat weakness of the recurrent laryngeal nerve.

Practice Recommendations to Minimize Dysphonia Post Thyroid Surgery

Visualization of the Nerve

The gold standard approach for preventing inadvertent injury to the RLN during thyroid surgery has always been meticulous dissection of the nerve in order to visualize its entry into the cricothyroid joint and/or course (14). Many prospective studies have confirmed Lahey’s observation in 1938 (15) that clear visualization of the RLN during thyroid surgery significantly lowers the incidence of nerve injury compared to surgery without visualization (1620). Yet the best method to prevent nerve injury has been greatly debated. Even with a visually intact RLN, function can been compromised (21). Generally, the rate of RLN paralysis is low in experienced hands for open neck approaches (temporary injury 2%–8%, permanent in 0.5%–3%), however the rate tends to be higher for malignant thyroid disease, enlarged goiters, Graves’ disease, re-operative cases, anatomic variability and surgeon’s inexperience (2224).

Most often, surgeons take a lateral approach for dissecting the thyroid in order to identify the RLN. Fixed landmarks, such as the cricothyroid joint, is a helpful guide for localizing the entry point of the RLN into the larynx. In certain situations a medial approach can be advantageous in cases with a nonrecurrent RLN, a large Tubercle of Zuckerkandl, or in cases with extrathyroidal extension of cancer along the distal RLN segment (with the exception of cricothyroid junction involvement), or large goiters (25). This approach allows for early and direct access to the RLN once the isthmus is divided and Berry’s ligament is exposed (25). Care must be taken to avoid inadvertent injury when localizing the RLN with the medial approach since up to 80% of the time, the RLN is located superficial to Berry’s ligament, and below it 15% of the time (26).

Intraoperative Nerve Monitoring

Over the past few decades, intraoperative nerve monitoring (IONM) has gained acceptance as an adjunct to nerve visualization during thyroid surgery and is used by most high volume thyroid surgeons in North America (27). The American Academy of Otolaryngology – Head and Neck Surgery guidelines have recommended its use, and it has become the standard of care at most institutions. Regardless of whether the surgeon has high-volume or low-volume experience, most would argue that IONM can aid the surgeon through difficult anatomical situations should the surgical field be impaired by bleeding, scarring or tumor infiltration that may complicate a clean dissection. However, IONM does not replace knowledge of the head and neck anatomy.

Whether IONM conveys a real advantage over no monitoring at all continues to be debated by endocrine surgeons (3, 14, 22, 23, 2831). Barczynski et al. and others have demonstrated statistically lower rates for transient RLN paralysis with IONM compared with visualization alone (32). Whereas, Higgins et al., did not report a statistically significant difference in the overall incidence of true vocal fold palsy (3.52%) for IONM compared with (3.12%) for nerve identification alone (31). In a Cochrane analysis, the rates of permanent RLN palsy (RR 0.77, 95% CI 0.33 to 1.77; P = 0.54; 4 trials; 2895 nerves at risk; very low-certainty evidence) and transient RLN palsy (RR 0.62, 95% CI 0.35 to 1.08; P = 0.09; 4 trials; 2895 nerves at risk; very low-certainty evidence) when IONM was compared with nerve visualization alone did not conclude firm evidence showing an advantage or disadvantage for prevention of RLN injury (23). However, in Zheng’s meta-analysis of over 12 different trials which included 36,487 participants, IONM was found to decrease the risk of transient RLN palsy, but had no significant effect on the permanent rate of injury (32).

The most widely available IONM system is one where two surface electrodes embedded in the endotracheal tube are positioned so they contact the vocal folds during intubation. This allows the surgeon to intermittently monitor the RLN or the vagus nerve with a handheld probe once the nerve has been surgically isolated (3, 27). This system is useful for confirming the localization of the RLN, for identifying whether there is a loss of signal from nerve injury, and to guide decision making for whether to stage the surgery in the case of an ipsilateral loss of signal during a bilateral procedure (3, 27, 33). Intermittent IONM has its limitations, namely the need to maintain constant contact with the surface electrodes on the endotracheal tube and the vocal folds to obtain an accurate EMG recording. Should the endotracheal tube shift during surgical manipulation, a false decrease or loss in the EMG signal can result. Once the surgery is in progress, it can be disruptive for the surgeon or the anesthetist to reposition the tube, particularly during remote access surgeries such as the transoral robotic approach (34). Various newer approaches have emerged to circumvent these limitations (33, 34).

Continuous IONM has evolved to circumvent the limitations of intermittent IONM so that nerve monitoring can occur continuously and in real time. It is beneficial for the early detection and prevention of thermal or traction injuries, thus allowing the surgeon to take immediate action if a change in the EMG is noted (28, 29). Some studies have noted improved outcomes with continuous monitoring relative to intermittent monitoring, which has spurred adoption in some centers (35). In a comparative study, Schneider et al., examined a total of 6029 patients, of whom 3139 underwent continuous and 2890 intermittent IONM (35). Continuous IONM independently reduced early postoperative vocal cord palsy 1.8-fold (OR 0.56) and permanent vocal cord palsy 29.4-fold (OR 0.034) compared with intermittent IONM (35). Early postoperative vocal cord palsies were 17.9-fold less likely to become permanent with continuous IONM than intermittent IONM, demonstrating the advantage for using continuous monitoring in the right clinical scenario (35).

Hemostasis with Energy Based Devices

With the modernization of thyroid surgery, advances have included the use of energy-based devices (EBD) as an extension from the “clamp-and-tie” technique that Theodore Kocher fathered in the 19th century. Today, hemostasis can be achieved in multiple ways: clamp-and-tie, electrocautery (monopoloar or bipolar), with hemostatic clips, and more advanced EBD that use thermal, ferromagnetic, or ultrasonic energy to ligate, seal and dissect tissue (36). Even though more advanced techniques with EBD have demonstrated reduced pain, wound drainage, decreased rates of neck hematoma and even hypocalcaemia (3740), the results for EBD are inconsistent in terms of rates of RLN injury compared with conventional approaches (41, 42). Several studies have demonstrated that traction and thermal injury are the first and second most common causes of iatrogenic RLN injury during thyroidectomy (39, 43, 44). As one would expect, the use of EBDs can generate high temperatures that can spread to critical structures such as the RLN causing indirect thermal spread or direct thermal injury (36). Thus, various guidelines are published to ensure that surgeons maintain a safe distance between the activated EBD tip and the surrounding soft tissue (36). It is also recommended that enough time lapses for the tip or blade to cool sufficiently before using the device to dissect tissue or work close to the RLN.

Depending on whether monopolar electrocautery or bipolar cautery is used, a safe distance must be maintained in order to protect critical structures. Care should be taken when using monopolar electrocautery adjacent to the RLN given that thermal spread is diffuse. In a porcine model, Wu et al. demonstrated that an activation distance of 5 mm is required to maintain safety with a cooling time of 1 s for monopolar electrocautery set at 15 Watts (45). For bipolar cautery the recommendations differ since the current is confined to the tissue between the two arms of the tines (forcep-shaped electrode). Wu et al. reported an activation distance of 3 mm from critical structures with a 1 s cooling time set at 30 Watts (45). For advanced bipolar EBDs such as the LigaSure Small Jaw and Ligasure Exact Dissector, Dionigo et al, recommend a safe activation distance of 2 mm with a 2-second interval for cooling the instrument tip before further dissecting tissue (46). Similar distances are noted for EBDs that deliver energy in the form of ultrasonic vibrations (such as the Harmonic) or Ferromagnetic energy (47). Regardless of the EBD used, surgeons should be aware of the device specific recommended distance needed for a safe dissection. The perception of distance may be altered in remote access surgery where the surgical field is closed and visualized via endoscope compared with traditional open neck approaches but is key for minimizing thermal injury and for improving voice outcomes.

Thermal injury to the RLN is more detrimental to voice outcomes than mechanical injury cause by traction or compression. Studies have demonstrated that thermal injury can cause irreversible changes to the nerve, damaging the endoneurium with temperatures at little as 60 Celsius (48). Most EBDs reach temperatures that exceed 200 Celsius when they are activated, and more than 350 Celsius with monopolar electrocautery (36). Additional care should be taken to avoid inadvertent injury to nearby structures when operating in a wet surgical field, as high temperature steam can be generated if the EBD is activated (49). Furthermore, surgeons should be aware and cautious when using EBDs as dissectors post-activation particularly during endoscopic approaches where the field of view can be limited.

Despite meticulous dissection along tissue planes, a slow oozing type of bleeding can still occur often around neural structures that are nourished by smaller vessels. The use of clips, cautery or ties adjacent to the nerve can pose risk. For this reason, various hemostatic agents have been developed in the form of a gel or patch to help mitigate this risk of a hematoma and nerve injury with cauterization. The use of such hemostatic agents, such as topical gels and patches have been shown to be a safe practice and does not put the RLN at risk. In a meta-analysis comparing the use of a topical hemostatic patch or gel to conventional methods for hemostasis, no significant difference between groups (patch 95% CI, 0.28, 5.52; gel 95% CI, 0.20, 2.47) were found in terms of risk to RLN injury (50).

Practice Recommendations to Minimize Dysphonia Post Thermal Ablation with RFA

The true rate of RLN injury post thermal ablation is not known since studies examining pre- and post-procedure laryngoscopy are lacking. However, the overall rate of transient or permanent voice change following RFA is 1.44% based on subjective voice assessment (11, 51).

Since RFA is done in an outpatient setting with local anesthesia, temporary voice changes can be noted either during radiofrequency ablation (RFA) or immediately after the procedure. The most important approach for mitigating this potential complication is to carefully map the location of the target nodule by ultrasound in relation to the “danger triangle”; which is localized posterior to the thyroid capsule and adjacent to the trachea where the RLN runs (52). The only study which specifically examined the effects of RFA along the posterior thyroid capsule is found in a recent prospective study. Sinclair et al. demonstrated in thirteen benign nodules that abutted the posterior thyroid capsule, that RFA could safety be performed at a power of up to 40 Watts without laryngeal adductor reflex (LAR) amplitude changes measured by continuous intraoperative neuromonitoring (CIONM) (13). No significant difference between pre- and postoperative laryngoscopy and voice assessments were noted, and after 12 month follow-up, regrowth was not noted at the posterior aspect of the nodule (13). For nodules that extend beyond the posterior thyroid capsule, or for nodules that lack a cuff of normal thyroid tissue, surgery should be considered instead of RFA due to the risk to the RLN and the lack of tissue to buffer thermal spread, especially if the nodule is malignant.

While RFA can be completed under general anesthesia with nerve monitoring, most operators feel that local sedation offers an improved safety profile. One of the benefits of an outpatient procedure is the real-time feedback that patients can give the operator in terms of pain control, change in voice or breathing. An important way to monitor for thermal damage to the RLN during ablation is to maintain communication with the patient during the procedure. Prior to the thermal ablation, perithyroidal lidocaine is injected around the anterior or superficial thyroid capsule to reduce pain. By avoiding anesthesia of the deeper tissues, if pain is experienced during the procedure, it can be an early sign of thermal propagation to the surrounding tissue and the electrode can be moved and then power can be reduced by 5 to 10 Watts before proceeding further (12, 53). If patients note changes to their voice immediately post-procedure, most often it is transient and can be treated with a short course of Prednisone during their recovery period. Furthermore, when using RFA to ablate bilateral thyroid nodules, care should be taken to monitor for voice changes to avoid bilateral RLN paresis. The operator should have a low threshold for staging bilateral procedures should dysphonia be noted during RFA.

Another useful approach for minimizing injury to the surrounding tissue (ie. RLN) prior to ablation is hydro-dissection with 5% dextrose solution along the plane between the target tumor and adjacent critical structures. This creates a thermal barrier as well as a “heat-sink effect” which allows for heat to escape during ablation (54). Dextrose solution is the fluid of choice since it is iso-molar (252 mOsmol/L) and non-ionic in composition, thus safer than normal saline which is anionic and able to conduct electricity. If thermal injury is suspected post-procedure, Lee et al. describe injecting cold 5% dextrose solution into the tracheoesophageal groove post-ablation as an effective method for cooling the tissues and for reducing heat conduction to surrounding structures (55). Compression of the neck is not recommended since it may enhance heat conduction to the surrounding tissue.

The safest technique described for performing RFA is the “moving shot technique”, which involves alternating the position of the electrode in the nodule so each theoretical sub-unit is ablated. This limits the frictional heat generated from the electrode tip by intermittent active movement and limits the time of ablation for each subunit to a few seconds compared to a fixed approach used in organs such as the liver (54). By using the trans-isthmic approach, which refers to insertion of a RF electrode through the isthmus, this allows the operator to be able to pivot from a midline to lateral direction to access different angles depending on whether the nodule is situated in the right or left thyroid gland, and enables the operator to ensure that the contents of the “danger triangle” can be protected (54). By inserting the probe in the midline, it allows the operator to effectively monitor the electrode tip using ultrasound guidance and to stabilize the needle should a patient talk or cough during the procedure.

Although multiple sized electrodes are available for targeting different organs, it is important to use thyroid-dedicated internally cooled electrodes for RFA given the superficial and intricate anatomy of the thyroid and neck. Generally, for the thyroid, RFA consists of a 7-cm internally cooled electro (shaft length) with an 18 or 19-gauge active tip that measures either 5 mm, 7 mm, 10 mm or 15 mm) with typical workhorse tips sizes of 7 mm or 10 mm depending on the patient population (54, 56). Depending on where the nodule is located, small active tips (3.8 mm) can allow for a more precise treatment limiting collateral thermal spread to nearby structures (54).

Correlation Between Intraoperative Electrophysiological Change of RLN/EBSLN and Voice Impairment in Thyroid Surgery

If a loss of signal or a decrease in the EMG amplitude is noted intraoperatively and equipment malfunction or neuromuscular blockage has been ruled out, careful stimulation of the nerve with the probe from distal (the laryngeal nerve entry site) to proximal is recommended to identify the site of neuropraxic injury. This is typically done for open neck procedures compared with closed remote access techniques. Generally, nerve injuries identified through intraoperative neural monitoring are divided into two types: Type I (segmental) or Type II (global) injury (27). Segmental injuries can be corrected if a section of the nerve is entrapped with a clip or a suture, however for global type injuries, where all segments are nonconductive, an intralaryngeal focus is more likely.

Several papers have looked at the correlation between intraoperative EMG responses and postoperative vocal cord mobility. The International Neural Monitoring Study Group Guideline describes an impending adverse EMG even defined as an amplitude decrease of >50% of the initial baseline value, and an adverse EMG event is defined as an amplitude of <100 uV (14, 27). A true negative test is one where the EMG response is within normal limits at the end of surgery with intact vocal cord mobility postoperatively. Several studies have demonstrated that when the EMG has a robust response at the end of surgery, intact post-operative vocal fold functioning (the negative predictive value) is more than 95% (5764). In a more recent review, Schneider et al., describe an even higher NPV for RLN palsy (97.3%–99.8%) when intermittent, and continuous (99.8%–100%) IONM is used (64). In contrast, if a loss of signal is noted on EMG at the end of surgery combined with immediate post-operative vocal cord paralysis, the outcome is a true positive test (27). However, for PPV, the rate is more variable due to transient versus permanent paresis, with a range of 37.8%–80.5% for intermittent, and 99.8%–100% for continuous IONM (63, 64). These values still translate into excellent outcomes with low rates of post-operative vocal cord palsy in experienced surgical hands, with early transient palsy 0.8%–10.5% for intermittent, and 2.6%–2.9% for continuous IONM (64). For permanent palsy, the rates are lower (0.2%–1.5% for intermittent, and 0%–1.0% for continuous IONM) (64). As a general rule, if there is an intact IONM signal at the end of the case, any post-operative voice changes are unlikely to be related to permanent RLN dysfunction.

Voice and Laryngeal Assessment Before and After Thyroid Surgery and Thermal Ablation

It is standard of care to assess the patient’s voice prior to thyroid surgery or thermal ablation to establish baseline function that can be compared post-surgically. As part of the history, patients should be asked about subjective changes in their pitch, loudness, quality or power of their voice (65). Validated standardized methods can also be employed, such as the Voice Handicap Index. This 30-item questionnaire determines the degree of voice impairment and has been used as a tool to determine pre- and postoperative voice status after thyroid surgery (66, 67). During physical exam, all patients with subjective voice changes should receive a preoperative glottic exam to ensure normal baseline glottic functioning. Approximately 1% of patients with benign thyroid disease have vocal fold paresis or paralysis and in up to 8% of patients with malignant thyroid disease who have not undergone prior thyroid, neck or chest surgery (68). Given that a preoperatively diagnosis for vocal fold paralysis is suspicious for thyroid cancer, such as finding may alter the surgeon’s approach to surgical resection as well as how the patient is counselled preoperatively regarding expected voice outcomes.

The most commonly available method for examining the larynx is by flexible nasopharyngoscopy. More traditional methods involve the mirror exam, but have increasingly been replaced by flexible nasopharyngoscopy. Video-strobo-laryngoscopy (VSL) is another way to do a detailed functional examination of the larynx, however is less readily available except in more laryngology-based practices.

Speech Therapy and Injection Laryngoplasty for Post-Thyroid Procedure Dysphonia (PTD)

When a patient presents with complains of breathiness, dyspnea and/or mild dysphagia post-thyroid surgery, and vocal fold immobility has been confirmed on flexible nasopharyngoscopy, several options that can be offered. The management of symptomatic patients post-thyroid surgery varies from patient to patient but can include speech therapy, vocal fold injection, thyroplasty, reconstructive approaches for unilateral vocal fold paralysis and tracheotomy for bilateral vocal fold paralysis (Figure 1).

FIGURE 1
www.frontiersin.org

Figure 1. Flow Chart summarizing the Management for Temporary and Permanent Post-Operative Dysphonia due to Unilateral Vocal Paresis.

The clinical practice guidelines for improving voice outcomes after thyroid surgery recommend that assessment of voice is done within 2 weeks to 2 months post-thyroid surgery by the surgeon (65). If voice changes are noted, a laryngeal mirror or flexible nasopharyngoscopy is done to document whether vocal fold paresis is present. If the surgeon does not have the equipment to assess the vocal folds, a referral is made to an Otolaryngologist – Head and Neck surgeon for further management. Once a diagnosis of unilateral vocal fold paresis is made or suspected, shared decision making with the patient regarding the next steps of management is made. Of note, the earlier the intervention with speech therapy and/or vocal fold injection (less than 3 months), the better the long-term outcomes in voice and swallowing for the patient (65).

Speech therapy focuses on rehabilitation of vocal fold approximation using behavioral approaches. The goal of voice therapy is to improve glottic closure by strengthening the intrinsic muscles of the larynx, rather than developing abdominal support for breathing and supraglottic hyperfunction (65). Procedural approaches include vocal fold injection, which is a temporary method to augment the immobile vocal fold to a more midline position. This outpatient procedure can improve laryngeal function by improving glottic closure during the recovery period, while also reducing the likelihood for permanent medialization laryngoplasty (69). In a retrospective review, Yung et al. demonstrated the benefit of temporary injection medialization in 19 patients with unilateral fold paresis compared with 35 patients who were managed conservatively (69). Those patients injected were significantly less likely to require permanent medialization laryngoplasty (p = 0.0131). In terms of the timing for injection medialization, Friedman et al., demonstrated the earlier the intervention, the better (70). In patients that had early injection medialization (less than 6 months from the time of injury to medialization), 62% (20/32) maintained an adequate voice obviating the need for open neck surgical reconstruction, whereas 100% (3/3) that underwent late injection (more than 6 months post paralysis) required surgical reconstruction (P = 0.03) (70).

For permanent unilateral vocal fold paralysis, medialization thyroplasty is an option to mobilize the vocal fold to a midline position through a small transcervical incision (71). Other permanent methods involve manipulating the laryngeal cartilage to perform an arytenoid adduction or arytenopexy (72, 73). These more advanced procedures involve an operating room setting and are generally done by surgeons with a laryngology based practice. Laryngeal reinnervation is another advanced procedure which is less commonly done, and typically performed by connecting the ansa cervicalis and the recipient RLN (74). Although there is a delay in voice improvement with this technique, it can partially improve the position of the vocal fold and provide bulk so long-term denervation atrophy of the laryngeal muscles is avoided (74). Often, the delay in voice improvement can be bridged with injection laryngoplasty. Depending on what was noted intraoperatively in terms of tumor involvement around the RLN, or transection of the nerve, decisions can be made to go directly to permanent solutions (such as medial thyroplasty, arytenoid adduction, arytenopexy or reinnervation surgery) if the nerve is deemed unlikely to recover.

Conclusion

Post-operative dysphonia has serious implications and consequences to patients, and thus, every effort should be taken to mitigate this complication. Various surgical and nonsurgical approaches can be taken reduce vocal fold injury during thyroid surgery as well as during thermal ablation. In symptomatic patients with RLN injury, various treatment options can be offered which range in behaviour therapy to more surgical type approaches to improve their quality of life.

Author Contributions

PP-A contributed to the literature review and manuscript writing. JOR contributed to the revisions as well as the manuscript finalization. All authors contributed to the article and approved the submitted version.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Haugen BR, Alexander EK, Bible KC, Doherty GM, Mandel SJ, Nikiforov YE, et al. 2015 American thyroid association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer: the american thyroid association guidelines task force on thyroid nodules and differentiated thyroid cancer. Thyroid. (2016) 26(1):1–133. doi: 10.1089/thy.2015.0020

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Dorairajan N, Pradeep PV. Vignette thyroid surgery: a glimpse into its history. Int Surg. (2013) 98(1):70–5. doi: 10.9738/CC185.1

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Schneider R, Randolph GW, Dionigi G, Wu CW, Barczynski M, Chiang FY, et al. International neural monitoring study group guideline 2018 part I: staging bilateral thyroid surgery with monitoring loss of signal. Laryngoscope. (2018) 128(Suppl 3):S1–S17. doi: 10.1002/lary.27359

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Yu W-HV, Wu C-W. Speech therapy after thyroidectomy. Gland Surg. (2017) 6(5):501. doi: 10.21037/gs.2017.06.06

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Borel F, Tresallet C, Hamy A, Mathonnet M, Lifante J-C, Brunaud L, et al. Self-assessment of voice outcomes after total thyroidectomy using the voice handicap index questionnaire: results of a prospective multicenter study. Surgery. (2020) 167(1):129–36. doi: 10.1016/j.surg.2019.05.090

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Borel F, Christou N, Marret O, Mathonnet M, Caillard C, Bannani S, et al. Long-term voice quality outcomes after total thyroidectomy: a prospective multicenter study. Surgery. (2018) 163(4):796–800. doi: 10.1016/j.surg.2017.09.023

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Wilson JA, Deary IJ, Millar A, Mackenzie K. The quality of life impact of dysphonia. Clin Otolaryngol Allied Sci. (2002) 27(3):179–82. doi: 10.1046/j.1365-2273.2002.00559.x

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Jones SM, Carding PN, Drinnan MJ. Exploring the relationship between severity of dysphonia and voice-related quality of life. Clin Otolaryngol. (2006) 31(5):411–7. doi: 10.1111/j.1749-4486.2006.01291.x

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Jeannon JP, Orabi AA, Bruch GA, Abdalsalam HA, Simo R. Diagnosis of recurrent laryngeal nerve palsy after thyroidectomy: a systematic review. Int J Clin Pract. (2009) 63(4):624–9. doi: 10.1111/j.1742-1241.2008.01875.x

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Roy N, Smith ME, Dromey C, Redd J, Neff S, Grennan D. Explorating the phonotory effets of external superior laryngeal nerve paralysis: an in vivo model. Laryngoscope. (2009) 119(4):816–26. doi: 10.1002/lary.20143

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Chung SR, Suh CH, Baek JH, Park HS, Choi YJ, Lee JH. Safety of radiofrequency ablation of benign thyroid nodules and recurrent thyroid cancers: a systematic review and meta-analysis. Int J Hyperthermia. (2017) 33:920–30. doi: 10.1080/02656736.2017.1337936

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Baek JH, Lee JH, Shung JY, Bae JI, Kim KT, Sim J, et al. Complications encountered in the treatment of benign thyroid nodules with US-guided radiofrequency ablation: a multicenter study. Korean Society of Thyroid Radiology. Radiology. (2012) 262(1):335–42. doi: 10.1148/radiol.11110416

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Sinclair CF, Tellez MJ, Pelaez-Cruz R, Diaz-Baamonde A, Ulkatan S. Continous neuromonitoring during radiofrequency ablation of benign thyroid nodules provides objective evidence of laryngeal nerve safety. Am J Surg. (2021) 222(2):354–60. doi: 10.1016/j.amjsurg.2020.12.033

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Maneeprasopchoke P, Chongkolwatana C, Pongsapich W, Iwata AJ, Kamani D, Randolph GW. Intraoperative nerve monitoring in thyroid surgery: Analysis of recurrent laryngeal nerve identification and operative time. Laryngoscope Investig Otolaryngol. (2021) 6(2):354–61. doi: 10.1002/lio2.543

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Lahey FH. Routine dissection and demonstration of recurrent laryngeal nerves in subtotal thyroidectomy. Surg Gynecol Obstet. (1938) 66:775–7.

Google Scholar

16. Riddel VH. Injury to recurrent laryngeal nerves during thyroidectomy: a comparison between the results of identification and non-identification in 1022 nerves exposed to risk. Lancet. (1956) 29:638–41. doi: 10.1016/S0140-6736(56)92333-9

CrossRef Full Text | Google Scholar

17. Jatzko GR, Lisborg PH, Muller MG, Wette VM. Recurrent nerve palsy after thyroid operations – principal nerve identification and a literature review. Surgery. (1994) 115:139–44.

PubMed Abstract | Google Scholar

18. Hermann M, Alk G, Roka R, Glaser K, Freissmuth M. Laryngeal recurrent nerve injury in surgery for benign thyroid disease: effect of the nerve dissection and impaction of individual surgeon in more than 27,000 nerves at risk. Ann Surg. (2002) 235:261–8. doi: 10.1097/00000658-200202000-00015

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Steurer M, Passler C, Denk DM, Schneider B, Niederle B, Bigenzahn W. Advantages of recurrent laryngeal nerve identification in thyroidectomy and parathyroidectomy and the importance of preoperative and posteroperative laryngoscopic examination in more than 1000 nerves at risk. Laryngoscope. (2002) 112:124–33. doi: 10.1097/00005537-200201000-00022

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Chiang FY, Wang LF, Huang YF, Lee KW, Kuo WR. Recurrent laryngeal nerve palpsy after thyroidectomy with routine identification of the recurrent laryngeal nerve. Surgery. (2005) 137:342–7. doi: 10.1016/j.surg.2004.09.008

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Serpell JW, Phan D. Safety of total thyroidectomy. ANZ J Surg. (2007) 77(1–2):15–9. doi: 10.1111/j.1445-2197.2006.03897.x

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Calò PG, Pisano G, Medas F, Pittau MR, Gordini L, Demontis R, et al. Identification alone versus intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroid surgery: experience of 2034 consecutive patients. Am J Otolaryngol Head Neck Surg. (2014) 43:16. doi: 10.1186/1916-0216-43-16

CrossRef Full Text | Google Scholar

23. Cirocchi R, Arezzo A, D’Andrea V, Abraha I, Popivanov GI, Avenia N, et al. Intraoperative neuromonitoring versus visual nerve identification for prevention of recurrent laryngeal nerve injury in adults undergoing thyroid surgery. Cochrane Database Syst Rev. (2019) 1:CD012483. doi: 10.1002/14651858.CD012483.pub2

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Snyder SK, Sigmond BR, Lairmore TC, Govednik-Horny CM, Janicek AK, Jupiter DC. The long-term impact of routine intraoperative nerve monitoring during thyroid and parathyroid surgery. Surgery. (2013) 154(4): 704–11; discussion 711–703. doi: 10.1016/j.surg.2013.06.039

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Butskiy O, Chang BA, Luu K, McKenzie RM, Anderson DW. A systematic approach to the recurrent laryngeal nerve dissection at the cricothyroid junction. J Otolaryngol Head Neck Surg. (2018) 47(57):1–9. doi: 10.1186/s40463-018-0306-7

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Henry BM, Sanna B, Graves MJ, Sanna S, Vikse J, Tomaszewska IM, et al. The Reliability of the tracheoesophageal groove and the Ligament of Berry as landmarks for identifying the Recurrent Laryngeal Nerve: a cadaveric study and meta-analysis. BioMed Res Int. (2017) 2017:1–11. doi: 10.1155/2017/4357591

CrossRef Full Text | Google Scholar

27. Randolph GW, Dralle H, Abdullah H, Barczynski M, Bellantone R, Brauckhoff M, et al. International intraoperative monitoring study electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope. (2011) 121(Suppl 1):S1–S16. doi: 10.1002/lary.21119

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Phelan E, Schneider R, Lorenz K, Dralle H, Kamani D, Potenza A, et al. Continuous vagal IONM prevents recurrent laryngeal nerve paralysis by revealing initial EMG changes of impending neuropraxic injury: a prospective, multicenter study. Laryngoscope. (2014) 124(6):1498–505. doi: 10.1002/lary.24550

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Dionigi G, Donatini G, Boni L, Rausei S, Rovera F, Tanda ML, et al. Continuous monitoring of the recurrent laryngeal nerve in thyroid surgery: a critical appraisal. Int J Surg. (2013) 11(Suppl):S44–6. doi: 10.1016/S1743-9191(13)60014-X

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Sanabria A, Kowalski LP, Nixon I, Angelos P, Shaha A, Owen RP, et al. Methodological quality of systematic reviews of intraoperative neuromonitoring in thyroidectomy: a systematic review. JAMA Otolaryngol Head Neck Surg. (2019) 145:563–73. doi: 10.1001/jamaoto.2019.0092

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Higgins TS, Gupta R, Ketcham AS, SataloK RT, Wadsworth JT, Sinacori JT. Recurrent laryngeal nerve monitoring versus identification alone on post-thyroidectomy true vocal fold palsy: a meta-analysis. Laryngoscope. (2011) 121(5):1009–17. doi: 10.1002/lary.21578

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Zheng S, Xu Z, Wei Y, Zeng M, He J. Effect of intraoperative neuromonitoring on recurrent laryngeal nerve palsy rates after thyroid surgery - a meta-analysis. J Formos Med Assoc. (2013) 112(8):463–72. doi: 10.1016/j.jfma.2012.03.003

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Sinclair CF, Tellez MJ, Ulkatan S. Continuous laryngeal adductor reflex versus intermittent nerve monitoring in neck endocrine surgery. Laryngoscope. (2020) 131:230–6. doi: 10.1002/lary.28710

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Liu CH, Huang TY, Wu CW, Wang JJ, Wang F, Chan LP, et al. New developments in anterior laryngeal recording technique during neuromonitored thyroid and parathyroid surgery. Front Endocrinol. (2021) 12:763170. doi: 10.3389/fendo.2021.763170

CrossRef Full Text | Google Scholar

35. Schneider R, Machens A, Sekulla C, Lorenz K, Elwerr M, Dralle H. Superiority of continuous over intermittent intraoperative nerve monitoring in preventing vocal cord palsy. Br J Surg. (2021) 108(5): 566–73. doi: 10.1002/bjs.11901

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Wang JJ, Huang TY, Wu CW, Lin YC, Tseng HY, Liu CH, et al. Improving voice outcomes after thyroid surgery – review of safety parameters for using energy-based devices near the recurrent laryngeal nerve. Front Endocrinol. (2021) 12:793431. doi: 10.3389/fendo.2021.793431

CrossRef Full Text | Google Scholar

37. Moran K, Grigorian A, Elfenbein D, Schubl S, Jutric Z, Lekawa M, et al. Energy vessel sealant devices are associated with decreased risk of neck hematoma after thyroid surgery. Updates Surg. (2020) 72(4):1135–41. doi: 10.1007/s13304-020-00776-9

PubMed Abstract | CrossRef Full Text | Google Scholar

38. Canu GL, Medas F, Podda F, Tatti A, Pisano G, Erdas E, et al. Thyroidectomy with energy-based devices: surgical outcomes and complications— comparison between harmonic focus, ligasure small jaw and thunderbeat open fine jaw. Gland Surg. (2020) 9(3):721. doi: 10.21037/gs.2020.03.31

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Dionigi G, Wu C-W, Kim H-Y, Liu X, Liu R, Randolph GW, et al. Safety of energy based devices for hemostasis in thyroid surgery. Gland Surg. (2016) 5(5):490. doi: 10.21037/gs.2016.09.01

PubMed Abstract | CrossRef Full Text | Google Scholar

40. Liu C-H, Wang C-C, Wu C-W, Lin Y-C, Lu I, Chang P-Y, et al. Comparison of surgical complications rates between ligasure small jaw and clamp-and tie hemostatic technique in 1,000 neuro-monitored Thyroidectomies. Front Endocrinol. (2021) 12:313. doi: 10.3389/fendo.2021.638608

CrossRef Full Text | Google Scholar

41. Pacilli M, Tartaglia N, Gerundo A, Pavone G, Fersini A, Ambrosi A. Energy based vessel sealing devices in thyroid surgery: a systematic review to clarify the relationship with recurrent laryngeal nerve injuries. Medicina. (2020) 56(12):651. doi: 10.3390/medicina56120651

CrossRef Full Text | Google Scholar

42. Garas G, Okabayashi K, Ashrafian H, Shetty K, Palazzo F, Tolley N, et al. Which hemostatic device in thyroid surgery? a network meta-analysis of surgical technologies. Thyroid. (2013) 23(9):1138–50. doi: 10.1089/thy.2012.0588

PubMed Abstract | CrossRef Full Text | Google Scholar

43. Dionigi G, Wu CW, Kim HY, Rausei S, Boni L, Chiang FY. Severity of recurrent laryngeal nerve injuries in thyroid surgery. World J Surg. (2016) 40(6):1373–81. doi: 10.1007/s00268-016-3415-3

PubMed Abstract | CrossRef Full Text | Google Scholar

44. Dionigi G, Alesina PF, Barczynski M, Boni L, Chiang FY, Kim HY, et al. Recurrent laryngeal nerve injury in video-assisted thyroidectomy: lessons learned from neuromonitoring. Surg Endosc. (2012) 26(9):2601–8. doi: 10.1007/s00464-012-2239-y

PubMed Abstract | CrossRef Full Text | Google Scholar

45. Wu C-W, Huang T-Y, Chen H-C, Chen H-Y, Tsai T-Y, Chang P-Y, et al. Intra-operative neural monitoring of thyroid surgery in a porcine model. JoVE. (2019) 144:e57919. doi: 10.3791/57919

CrossRef Full Text | Google Scholar

46. Dionigi G, Chiang FY, Kim HY, Randolph GW, Mangano A, Chang PY, et al. Safety of ligasure in recurrent laryngeal nerve dissection-porcine model using continuous monitoring. Laryngoscope. (2017) 127(7):1724–9. doi: 10.1002/lary.26271

PubMed Abstract | CrossRef Full Text | Google Scholar

47. Wu CW, Chai YJ, Dionigi G, Chiang FY, Liu X, Sun H, et al. Recurrent laryngeal nerve safety parameters of the H armonic focus during thyroid surgery: porcine model using continuous monitoring. Laryngoscope. (2015) 125(12):2838–45. doi: 10.1002/lary.25412

PubMed Abstract | CrossRef Full Text | Google Scholar

48. Lin YC, Dionigi G, Randolph GW, Lu IC, Chang PY, Tsai SY, et al. Electrophysiologic monitoring correlates of recurrent laryngeal nerve heat thermal injury in a porcine model. Laryngoscope. (2015) 125(8):E283–90. doi: 10.1002/lary.25362

PubMed Abstract | CrossRef Full Text | Google Scholar

49. Hayami M, Watanabe M, Mine S, Imamura Y, Okamura A, Yuda M, et al. Steam induced by the activation of energy devices under a wet condition may cause thermal injury. Surg Endoscopy. (2020) 34(5):2295–302. doi: 10.1007/s00464-019-07312-w

CrossRef Full Text | Google Scholar

50. Khadra H, Bakeer M, Hauch A, Hu T, Kandil E. Gland Surg. (2018) 7(Suppl 1):S34–S41. doi: 10.21037/gs.2018.03.02

PubMed Abstract | CrossRef Full Text | Google Scholar

51. Orloff L, Noel JE, Stack BC Jr, Russell MD, Angelos P, Baek JH, et al. Radiofrequency ablation and related ultrasound-guided ablation technologies for for treatment of benign and malignant thyroid disease: An international multidisciplinary consensus statement of the American Head and Neck Society Endocrine Surgery Section with the Asia Pacific Society of Thyroid Surgery, Associazione Medici Endocrinologi, British Association of Endocrine and Thyroid Surgeons, Europoean Thyroid Association, Italian Thyroid Radiology, Latin American Thyroid Society and Thyroid Nodules Therapies Association. Head & Neck. (2021) 44(3): 633–660. doi: 10.1002/hed.26960

CrossRef Full Text | Google Scholar

52. Ha EJ, Baek JH, Lee JH. Ultrasonography-based thyroidal and perithyroidal anatomy and its clinical significance. Ko­rean J Radiol. (2015) 16:749–66. doi: 10.3348/kjr.2015.16.4.749

CrossRef Full Text | Google Scholar

53. Park HS, Baek JH, Park AW, Chung SR, Choi YJ, Lee JH. Thyroid radiofrequency ablation: updates on innovative devices and techniques. Korean J Radiol. (2017) 18(4):615–23. doi: 10.3348/kjr.2017.18.4.615

PubMed Abstract | CrossRef Full Text | Google Scholar

54. Park HS, Baek JH, Choi YJ, Lee JH. Innovative techniques for image-guided ablation of benign thyrid nodules: combined ethanol and radiofrequency ablation. Korean J Radiol. (2017) 18(3):461–9. doi: 10.3348/kjr.2017.18.3.461

PubMed Abstract | CrossRef Full Text | Google Scholar

55. Lee MK, Baek JH, Chung SR, Choi YJ, Lee YM, Kim TY, et al. Effectiveness of injection cold 5% Dextrose into patients with nerve damage symptoms during thyroid Radiofrequency Ablation. Endocrinol Metab. (2020) 35:407–15. doi: 10.3803/EnM.2020.35.2.407

CrossRef Full Text | Google Scholar

56. Jeong SY, Baek JH, Choi YJ, Lee JH. Ethanol and thermal ablation for malignant thyroid tumours. Int J Hyperthermia. (2017) 33:938–45 doi: 10.1080/02656736.2017.1361048

PubMed Abstract | CrossRef Full Text | Google Scholar

57. Tomoda C, Hirokawa Y, Uruno T, Takamura Y, Ito Y, Miya A, et al. Sensitivity and specificity of intraoperative recurrent laryngeal nerve stimulation test for predicting vocal cord palsy after thyroid surgery. World J Surg. (2006) 30:1230–3. doi: 10.1007/s00268-005-0351-z

PubMed Abstract | CrossRef Full Text | Google Scholar

58. Hamelmann WH, Meyer T, Timm S, Timmermann W. A critical estimation of intraoperative neuromonitoring (IONM) in thyroid surgery. Zentralbl Chir. (2002) 127:409–13. doi: 10.1055/s-2002-31982

PubMed Abstract | CrossRef Full Text | Google Scholar

59. Chan WF, Lang BH, Lo CY. The role of intraoperative neuromonitoring of recurrent laryngeal nerve during thyroidectomy: a comparative study on 1000 nerves at risk. Surgery. (2006) 140:866–72; discussion 872–873. doi: 10.1016/j.surg.2006.07.017

PubMed Abstract | CrossRef Full Text | Google Scholar

60. Thomusch O, Sekulla C, Machens A, Neumann HJ, Timmermann W, Dralle H. Validity of intraoperative neuromonitoring signals in thyroid surgery. Langenbecks Arch Surg. (2004) 389:499–503. doi: 10.1007/s00423-003-0444-9

PubMed Abstract | CrossRef Full Text | Google Scholar

61. Beldi G, Kinsbergen T, Schlumpf R. Evaluation of intraoperative recurrent nerve monitoring in thyroid surgery. World J Surg. (2004) 28:589–91. doi: 10.1007/s00268-004-7226-6

PubMed Abstract | CrossRef Full Text | Google Scholar

62. Hermann M, Hellebart C, Freissmuth M. Neuromonitoring in thyroid surgery: prospective evaluation of intraoperative electrophysiological responses for the prediction of recurrent laryngeal nerve injury. Ann Surg. (2004) 240:9–17. doi: 10.1097/01.sla.0000132260.34503.02

PubMed Abstract | CrossRef Full Text | Google Scholar

63. Dralle H, Sekulla C, Lorenz K, Brauckhoff M, Machens A. German IONM Study Group: Intraoperative monitoring of the recurrent laryngeal nerve and thyroid surgery. World J Surg. (2008) 32:1358–66. doi: 10.1007/s00268-008-9483-2

PubMed Abstract | CrossRef Full Text | Google Scholar

64. Schneider R, Machens A, Lorenz K, Dralle H. Intraoperative nerve monitoring in thyroid surgery – shifting current paradigms. Gland Surg. (2020) 9(Suppl 2):S120–8.

PubMed Abstract | Google Scholar

65. Chandrasekhar SS, Randolph GW, Seidman MD, Rosenfeld RM, Angelos P, Barkmeier-Kraemer J, et al. Clinical practice guideline: improving voice outcomes after thyroid surgery. Otolaryngol Head Neck Surg. (2013) 148(6S):S1–S37. doi: 10.1177/0194599813487301

PubMed Abstract | CrossRef Full Text | Google Scholar

66. Stojadinovic A, Henry LR, Howard RS, Gurevich-Uvena J, Makashay MJ, Coppit GL, et al. Prospective trial of voice outcomes after thyroidectomy: evaluation of patient-reported and clinician-determined voice assessments in identifying post-thyroidectomy dysphonia. Surgery. (2008) 143(6):732–42. doi: 10.1016/j.surg.2007.12.004

PubMed Abstract | CrossRef Full Text | Google Scholar

67. Jacobson BH, Johnson A, Grywalski C, Silbergleit A, Jacobson G. The voice handicap index (VHI): development and validation. Am J Speech Lang Pathol. (1997) 6(3):66–70. doi: 10.1044/1058-0360.0603.66

CrossRef Full Text | Google Scholar

68. Row-Jones JM, Leighton SEJ, Rosswick RO. Benign thyroid disease and vocal cord palsy. Ann RCS Eng. (1993) 75:241–4. PMID: 8379624 PMCID: PMC2497920.

Google Scholar

69. Yung KC, Likhterov I, Courey MS. Effect of temporary vocal fold injection medialization on the rate of permanent medialization laryngoplasty in unilateral vocal fold paralysis patients. Laryngoscope. (2011) 121(10): 2191–4. doi: 10.1002/lary.21965

PubMed Abstract | CrossRef Full Text | Google Scholar

70. Friedman AD, Burns JA, Heaton JT, Zeitels SM. Early versus late injection medialization for unilateral vocal cord paralysis. Laryngoscope. (2010) 120(10):2191–4. doi: 10.1002/lary.21097

CrossRef Full Text | Google Scholar

71. Isshiki N, Okamura H, Ishikawa T. Thyroplasty type I (lateral compression) for dysphonia due to vocal cord paralysis or atrophy. Acta Otolaryngol. (1975) 80(5–6):465–73. doi: 10.3109/00016487509121353

PubMed Abstract | CrossRef Full Text | Google Scholar

72. Isshiki N, Tanabe M, Sawada M. Arytenoid adduction for unilateral vocal cord paralysis. Arch Otolaryngol. (1978) 104(10):555–8. doi: 10.1001/archotol.1978.00790100009002

PubMed Abstract | CrossRef Full Text | Google Scholar

73. Zeitels SM, Mauri M, Dailey SH. Adduction arytenopexy for vocal fold paralysis: indications and technique. J Laryngol Otol. (2004) 118(7):508–16. doi: 10.1258/0022215041615263

PubMed Abstract | CrossRef Full Text | Google Scholar

74. Aynehchi BB, McCoul ED, Sundaram K. Systematic review of laryngeal reinnervation techniques. Otolaryngol Head Neck Surg. (2010) 143(6): 749–59. doi: 10.1016/j.otohns.2010.09.031

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: thyroid surgery, radiofrequency ablation, dysphonia, voice, vocal cord dysfunction

Citation: Pace-Asciak P, Russell JO and Tufano RP (2022) Improving Voice Outcomes after Thyroid Surgery and Ultrasound-Guided Ablation Procedures. Front. Surg. 9:882594. doi: 10.3389/fsurg.2022.882594

Received: 24 February 2022; Accepted: 11 April 2022;
Published: 4 May 2022.

Edited by:

Kyung Tae, Hanyang University, South Korea

Reviewed by:

Leandro Luongo Matos, Clinical Hospital, Faculty of Medicine, University of São Paulo, São Paulo, Brazil
Navid Tabriz, Pius-Hospital Oldenburg, Oldenburg, Germany

Copyright © 2022 Pace-Asciak, Russell and Tufano. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Ralph P. Tufano Ralph-Tufano@smh.com

Speciality section: This article was submitted to Otorhinolaryngology - Head and Neck Surgery, a section of the journal Frontiers in Surgery

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.