Skip to main content

ORIGINAL RESEARCH article

Front. Surg., 02 November 2022
Sec. Orthopedic Surgery
This article is part of the Research Topic Novel Techniques of Minimally Invasive Spine Surgery for Various Pathologies View all 31 articles

Contralateral bridge fixation of freehand minimally invasive pedicle screws combined with unilateral MIS-TLIF vs. open TLIF in the treatment of multi-segmental lumbar degenerative diseases: A five years retrospective study and finite element analysis

\r\nYingkai Zhang,,&#x;Yingkai Zhang1,2,†Tianyao Zhou,,&#x;Tianyao Zhou1,3,†Yutong Gu,
Yutong Gu1,3*Wu CheWu Che1Liang ZhangLiang Zhang1Yichao Wang\r\nYichao Wang1
  • 1Department of Orthopaedic Surgery, Zhongshan Hospital Fudan University, Shanghai, China
  • 2Department of Orthopaedic Surgery, Jinshan Hospital of Fudan University, Shanghai, China
  • 3Shanghai Southwest Spine Surgery Center, Shanghai, China

Objective: To evaluate the efficacy, safety, feasibility and biomechanical stability of contralateral bridge fixation of freehand minimally invasive pedicle screws (Freehand MIPS) combined with unilateral minimally invasive surgery-transforaminal lumbar interbody fusion (MIS-TLIF) (smile-face surgery) and open TLIF for the treatment of multi-segmental lumbar degenerative diseases (LDDs).

Methods: From January 2013 to January 2016, clinical data of multi-segmental (2- or 3-level) LDDs receiving smile-face surgery or open TLIF were retrospectively collected and analyzed. The back and leg pain VAS and ODI were used to assess clinical outcomes preoperatively and postoperatively. The MacNab criteria were used to evaluate the satisfaction of patient. The disc height (DH), lumbar lordosis (LL) and segmental lordosis angle (SLA) were measured before and after surgery. We used patient's CT data to establish the finite element model of smile-face surgery and open TLIF, and analyze biomechanical stability of two methods.

Results: Smile-face surgery group showed shorter operation time, shorter incision, less blood loss, shorter hospital stay than open TLIF (P < 0.05). The back VAS in smile-face surgery group was significantly lower than that in open TLIF immediately and 3 months after surgery, and no significant difference was observed 1 year, 2 years and 5 years after surgery. There was no significant difference in the leg pain VAS and ODI between both groups after surgery. No significant difference was observed between two groups in the DH, LL and SLA. At 5-year follow-up, grade I or II fusion was achieved in 99.00% (100/101) segments of smile-face surgery group and 97.67% (84/86) segments of open TLIF group according to Bridwell system. The complication rate of open TLIF was higher than that of smile-face surgery (24.32% vs. 0%, P < 0.01). After verification, the established finite element model can accurately simulate the biological structure of lumbar spine and there was no significant difference in biomechanical stability between two methods.

Conclusions: Smile-face surgery has some advantages over open TLIF including smaller aggression, less blood loss, and lower cost, indicating that it is a good choice of treatment for multi-segmental LDDs. Both methods can achieve good biomechanical stability.

Introduction

Conventional posterior/transforaminal lumbar interbody fusion (PLIF, TLIF) has yielded satisfactory clinical outcomes for lumbar degenerative diseases (LDDs) (1, 2). However, iatrogenic paraspinal muscle injury, posterior tension band disruption, and approach-related complications are a concern (2, 3). In recent years, minimally invasive surgery-transforaminal lumbar interbody fusion (MIS-TLIF) has been widely used in order to improve open TLIF, which can protect the attachment of paraspinal muscles to bone, avoid the disruption of supraspinous and interspinous ligaments, and decreased the bleeding and postoperative pain (4). But most studies of MIS-TLIF have focused on single-level fusion, there are relatively few reports of MIS-TLIF for two or more levels. In this study, contralateral bridge fixation of freehand minimally invasive pedicle screws (Freehand MIPS) (510) combined with unilateral MIS-TLIF for bilateral neurological decompression was performed for the treatment of patients with multi-segmental (2- or 3-level) LDDs. The efficacy, safety, and feasibility of this minimally invasive method were compared with those of open TLIF.

Materials and methods

This study was approved by the Medical Ethics Committee of Zhongshan Hospital Fudan University (B2015–047), and all methods were carried out in accordance with relevant guidelines and regulations. Before the procedure, all patients provided informed consent.

Patients

From January 2013 to January 2016, clinical data of multi-segmental (2- or 3-level) LDDs (spondylolisthesis, disc herniation with instability or spinal canal stenosis) who received contralateral bridge Freehand MIPS combined with unilateral MIS-TLIF and open TLIF were retrospectively collected and analyzed.

The inclusion criteria included: (1) low back pain and leg pain lasting at least 6 months; (2) multi-segmental (2- or 3-level) LDDs of disc herniation with instability, spondylolisthesis (≤ grade II), or lumbar canal stenosis, corresponding to neurological symptoms (Figures 1A, 2A, 3A); (3) no relief of symptoms after conservative treatments and a significant decline in quality of daily life.

FIGURE 1
www.frontiersin.org

Figure 1. (A) sagittal MR images showed 3-level LDD (L2–L5) in a 75-year-old man with neurologic symptoms. (B) Contralateral bridge Freehand MIPS combined with unilateral MIS-TLIF through tube was performed. After the cage was inserted into the intervertebral space through the tube, (C) the fluoroscopic image confirmed the position of cage. (D) The picture was postoperative incision like smile face, so this MIS-TLIF is called smile-face surgery. (E, F) Postoperative x-ray showed that the position of pedicle screws and cages was good and (G) axial CT scan confirmed that the neurologic decompression was complete. In (H) sagittal CT at 5-year follow-up, fusion of grade I or II was achieved.

FIGURE 2
www.frontiersin.org

Figure 2. (A) sagittal MRI showed 2-level LDD (L3–L5) in a 72-year-old woman with neurologic symptoms. (B) Contralateral bridge Freehand MIPS combined with unilateral MIS-TLIF through tube was performed. After the cage was inserted into the intervertebral space through the tube, (C) the fluoroscopic image confirmed the position of cage. (D) The picture showed the incision like smile face, so this MIS-TLIF is called smile-face surgery. On (E, F) postoperative x-ray the position of pedicle screws and cages was good and (G) axial CT scan confirmed that the neurologic decompression was complete. On (H) sagittal CT at 5-year follow-up, fusion of grade I was achieved.

FIGURE 3
www.frontiersin.org

Figure 3. (A) sagittal MR images showed 3-level LDD (L2-L5) in a 69-year-old woman. Open TLIF was performed and (B, C) postoperative x-ray confirmed that the position of pedicle screws and cages was good. (D) The picture was postoperative incision. (E) CT scan image at 5-year follow-up showed that the neurologic decompression was complete and fusion of grade I or II was achieved.

The exclusion criteria were as followed: (1) patients with a history of spinal surgery, active infections, lumbar fractures, spine tumors, severe osteoporosis, or severe obesity; (2) patients with coronal and/or sagittal deformities that require surgical correction; (3) any serious psychological problem; (4) degenerative spondylolisthesis with severe instability or isthmic spondylolisthesis.

Surgical procedure

Contralateral bridge freehand MIPS combined with unilateral MIS-TLIF

After general anesthesia, the patient was placed on a radiolucent operating table in a prone position. The pedicles of two end vertebrae involved were identified under fluoroscopy and the skin was marked.

First, Freehand MIPS was performed for the contralateral two end vertebrae (510). Cannulated or normal pedicle screws were placed into the vertebral bodies through a minimal access under direct vision. In a paraspinal muscle-splitting approach, mini-incision was performed to expose the root of transverse process and superior articular process. The entrance point of the pedicle was located at the junction between the 1/2 line of transverse process and the lateral border of superior articular process. A hand-held curette was used to enter the pedicle and the integrity of the pedicle was confirmed using a probe to ensure a solid tube of bone. Two suitable lengths of pedicle screws were placed into the vertebral body through the pedicle. Posteoanterior and lateral x-ray examinations were performed to check their position.

Second, normal pedicle screws were placed in all involved vertebrae at the decompression side through the paraspinal muscle-splitting approach. In an incision 2.5 cm lateral to the midline including the pedicles of two end vertebrae, the lamina, root of the transverse process, and superior articular process were exposed. Once the entry position of pedicle was identified, the pedicle screws were inserted into vertebrae as described above.

Third, unilateral MIS-TLIF was implemented via the expandable tubular retractor. The tubular retractor was introduced along the stepwise dilating cannulas to the facet joints and lamina through the middle point of open approach. The semi-laminae, hypertrophied superior/inferior articular processes, and ligamenta flava were removed to expose the nerve roots and dural sac for neurologic decompression (Figures 1B, 2B). After discectomy, the vertebral endplates were prepared via the intervertebral foramen. Sufficient autologous bone graft from the resected lamina and facets was packed into the anterior intervertebral space. A single PEEK cage containing autologous bone was inserted obliquely across the prepared intervertebral space for TLIF (Figures 1C, 2C). When there was severe spinal canal stenosis with bilateral neurologic symptoms, the expandable tubular retractor was tilted further by approximately 15° to remove the root of spinal process and the inner cortical bone of contralateral lamina for the decompression of contralateral nerve. During surgery, the nerve roots and dural sac were protected. None of the patients enrolled in the study underwent additional contralateral facet joint fusion. The decompression and fusion procedure of other spinal segments was performed as described above.

Fourth, the rods were installed over the pedicle screws. Two rods of appropriate size were contoured to maintain a normal spine curve. One rod was placed over the pedicle screws through the open approach, and the other rod was placed over the two contralateral pedicle screws of the upper and lower end vertebrae through subcutaneous soft tissues and muscles to form a “bridge”, which we termed “contralateral bridge Freehand MIPS”. On the surface of skin, a small face can be seen after this kind of MIS-TLIF, so it is also called “smile-face surgery” (Figures 1D–F, 2D–F).

Open TLIF

A posterior midline incision was made over the lumbar spine and the paraspinal muscles were detached from the spinous process, lamina, facet capsules and transverse processes. The pedicle screws were inserted into all involved vertebrae via both pedicles, followed by laminectomy and facetectomy for neurologic decompression. After discectomy was done and the endplates were prepared, autologous bone and the PEEK cage with autologous bone were inserted into intervertebral space for TLIF. Two rods were fixed over the pedicle screws (Figures 3B,C,D).

When the drainage volume was less than 20 ml/24 h, the drainage tube was pulled out. The patients were mobilized as soon as feasible after surgery. No external braces were used after surgery. After leaving the hospital, the patients were encouraged to resume their daily routine and were followed-up in the outpatient.

Clinical follow-up

The operation time, blood loss, frequency of intraoperative fluoroscopy, length of surgical incision, hospital stay, hospitalization cost and postoperative complications were recorded.

The patient's lower back and leg pain were graded using the VAS pain rating score. ODI was used to assess the disability status preoperatively and at 5-year follow-up.

Pre- and postprocedural imaging

All patients were evaluated before the procedure by CT and MRI imaging to determine the involved levels. x-ray examination was performed for all patients and radiographic outcomes, including disc height (DH), lumbar lordosis (LL) and segmental lordosis angle (SLA), were measured before and after surgery. DH: the vertical distance from the anterior and posterior lower endplate of upper vertebra to the upper endplate of lower vertebra is measured, and then the mean is DH; LL: the Cobb Angle between the upper endplate of L1 and the upper endplate of S1; SLA: the Cobb angle between the superior endplate of superior vertebra and the inferior endplate of inferior vertebra or the superior endplate of S1 in the surgical segment. Two experienced orthopedic surgeons who did not participate in the surgery separately evaluated the fusion status on the basis of Bridwell's posterior fusion grades (11). When there were disagreements, another radiologist was asked to assess as the final result. The cage dropped into 2 mm was considered to be subsidence according to Knox (12).

Establish the finite element model of lumbar spine

This study was based on 3D CT data of lumbar spine before and after operation of a male patient, aged 53 years, 1.75 m in height and 72 kg in weight. Before operation, the lumbar was scanned using thin-slice CT with a slice thickness of 1 mm. Thereafter, the image was saved and exported in Dicom format, and the CT image of lumbar was modeled. The acquisition of CT data was carried out after obtaining the informed consent of patients. The finite element (FE) model of smile-face surgery and open TLIF were established by computer software respectively. Mimics 19.0 was used to build a 3D geological model in STL format for Dicom format images, and the STL file was imported into Geomagic Studio 2014 to enable the surface fitting and smoothing. The femur structure model was imported corresponding to each group into Hypermesh 14.0 software for mesh generation. The finite element model was imported into the Ansys 2021 software. The material properties of the lumbar spine's L1–S1 finite element model are listed in Table 1.

TABLE 1
www.frontiersin.org

Table 1. Material properties of the finite element model.

Biomechanical analysis of finite element model of lumbar spine

The established finite element model was compared with that in the in vitro cadaver study by Yamamoto to verify the reliability of model (13). To more directly compare the stability of two kinds of fusion modes, a concentrated moment of normal physiological load (7.5 Nm) was applied. The lumbar left and right axial rotation were observed by applying a moment of normal physiological load (7.5 Nm) along the horizontal direction of L1 vertebral body upper endplate of two models. The lumbar flexion and extension were observed by applying a moment of normal physiological load (7.5 Nm) along the direction perpendicular to the L1 vertebral body upper endplate; The lateral bending was observed by applying a moment of normal physiological load (7.5 Nm) along the direction perpendicular to the L1 vertebral body upper endplate, and to observe the angle changes of model in six directions. The degree of stability of two fusion modes was compared. The changes in the stress of screws were recorded through finite element analysis, and the difference between two kinds of fusion methods were evaluated. To demonstrate the biomechanical stability of 2-level and 3-level surgery respectively, we established different models for analysis.

Statistical analysis

Normal distributed continuous variables including age, operation time, blood loss, length of surgical incision, hospitalization cost, follow-up time, ODI, DH, LL and SLA are presented as mean ± standard deviation (SD); Categorical variables such as gender and complications are expressed as frequency or percentage; Discrete, rating variables and continuous variables, which are not normally distributed, are presented as median (Maximum- Minimum) including intraoperative fluoroscopy, drainage tube removal time, hospital stay and VAS score. T test is used for intergroup analysis of normal distributed continuous variables. The Mann–Whitney U test is used for intergroup analysis of discrete variables, rating variables, and not normally distributed continuous variables. The chi-square test is used for intergroup analysis of categorical variables. All analyses are performed using the Statistical Package for the Social Sciences (SPSS 20.0).

Results

The characteristics of samples are detailed in Table 2. No significant differences in patients' demographic data were noted between two groups. 82 patients were retrospectively selected for this study. Based on the surgical method used, the patients were divided into 45 cases in MIS-TLIF group (34 cases with 2 segments and 11 cases with 3 segments, a total of 101 segments) and 37 cases in open TLIF group (25 cases with 2 segments and 12 cases with 3 segments, a total of 86 segments). Patients were followed up for at least five years, and the longest follow-up was 8 years.

TABLE 2
www.frontiersin.org

Table 2. Sample characteristics of two groups.

Clinical efficacy evaluation

Smile-face surgery and open TLIF were successfully performed for all cases. The blood loss, length of operative incision, and hospital stay in MIS-TLIF group were significantly less than those in open TLIF group. There was no significant difference in the frequency of intraoperative fluoroscopy and operation time between two groups (Table 2). The VAS of low back in MIS-TLF group was significantly lower than that in open TLIF group immediately and 3 months after surgery, and no significant difference was observed 1 year, 2 years and 5 years after surgery. There was no significant difference in the postoperative VAS of leg pain and the ODI score at 5-year follow-up between MIS-TLIF group and open MIS-TLIF group (Table 3). The complication rate of open TLIF was higher than that of MIS-TLIF (24.32% vs. 0%, P < 0.01) (Table 2).

TABLE 3
www.frontiersin.org

Table 3. VAS of low back, leg and ODI in two groups.

Radiographic outcomes

Postoperative x-ray and CT confirmed that the position of cages and screws was good and the neurologic decompression was complete (Figures 1E–G, 2E–G, 3B,C,E). DH, LL and SLA significantly improved after surgery (P < 0.05). There was no significant difference between two groups in the DH, LL and SLA preoperatively, immediately, 3 months, 6 months, 1 year, 2 years and 5 years postoperatively (Table 4). At 5-year follow-up, 63 segments with Grade I fusion, 37 segments with Grade II fusion and 1 segments with Grade III fusion were observed in MIS-TLIF group (Figures 1H, 2H); In open TLIF group, 51 cases with Grade I fusion, 36 cases with Grade II fusion and 2 cases with Grade III fusion in were observed (Figure 3E).

TABLE 4
www.frontiersin.org

Table 4. Dh, LL and SLA of two groups.

Verification of finite element model

A moment of physiological load of 7.5 Nm was applied to the L1 in all directions, and the angles of movement in the directions of flexion, extension, lateral bending, and axial rotation were compared. As measured, the range of motion (ROM) of finite element model under the six directions was similar to that of in vitro model, and the differences in the results were acceptable considering the individual differences in the models themselves. Therefore, the established finite element model can accurately simulate the biological structure of lumbar spine (Table 5, Figure 4).

FIGURE 4
www.frontiersin.org

Figure 4. The finite element model of stable lumbar (L1-S1). (A) lateral view. (B) anteroposterior view.

TABLE 5
www.frontiersin.org

Table 5. Comparison of range of motion between the finite element model and the cadaveric study by Yamamoto et al.

Maximum Von mises stress of lumbar interbody fusion model

We next analyzed the stress of two kinds of fusion (Figure 5): In the 3-level model, the von Mises stress of screw of smile-face surgery ranged in 83 MPa in L2, in 45 MPa L3, 43 MPa in L4 and 78 MPa in L5 and the open TLIF ranged in 76 MPa in L2, in 41 MPa L3, in 39 MPa L4, in 71 MPa L5 in the flexion direction; The von Mises stress of screw of MIS-TLIF ranged in 63 MPa in L2, 46 MPa in L3, 43 MPa in L4 and 64 MPa in L5 and the open TLIF ranged in 59 MPa in L2, 37 MPa in L3, 34 MPa in L4, 34 MPa in L5 in the extension direction; The von Mises stress of screw of MIS-TLIF ranged in 42 MPa in L2, 37 MPa in L3, 37 MPa in L4 and 40 MPa in L5 and the open TLIF ranged 33 MPa in L2, 28 MPa in L3, 33 MPa in L4, 31 MPa in L5 in the left lateral bending direction; The von Mises stress of screw of MIS-TLIF ranged in 34 MPa in L2, 30 MPa in L3, 28 MPa in L4 and 35 MPa in L5 and the open TLIF ranged 33 MPa in L2, 27 MPa in L3, 34 MPa in L4, 31 MPa in L5 in the right lateral bending direction; The von Mises stress of screw of MIS-TLIF ranged in 55 MPa in L2, 51 MPa in L3, 48 MPa in L4 and 56 MPa in L5 and the open TLIF ranged in 45 MPa in L2, 40 MPa in L3, 39 MPa in L4, 48 MPa in L5 in the left axial rotation direction; The von Mises stress of screw of MIS-TLIF ranged in 49 MPa in L2, 45 MPa in L3, 42 MPa in L4 and 51 MPa in L5 and the open TLIF ranged in 46 MPa in L2, 41 MPa in L3, 38 MPa in L4, 47 MPa in L5 in the right axial rotation direction (Figure 6). In the 2-level model, the von Mises stress of screw of smile-face surgery ranged in 95 MPa in L3, 60 MPa in L4 and 87 MPa in L5 and the open TLIF ranged in 86 MPa in L3, 49 MPa in L4, 79 MPa in L5 in the flexion direction; The von Mises stress of screw of MIS-TLIF ranged in 84 MPa in L3, 64 MPa in L4 and 78 MPa in L5 and the open TLIF ranged in 78 MPa in L3, 49 MPa in L4, 71 MPa in L5 in the extension direction; The von Mises stress of screw of MIS-TLIF ranged in 46 MPa in L3, 38 MPa in L4 and 46 MPa in L5 and the open TLIF ranged in 38 MPa in L3, 29 MPa in L4, 38 MPa in L5 in the left lateral bending direction; The von Mises stress of screw of MIS-TLIF ranged in 42 MPa in L3, 32 MPa in L4 and 43 MPa in L5 and the open TLIF ranged in 38 MPa in L3, 29 MPa in L4, 38 MPa in L5 in the right lateral bending direction; The von Mises stress of screw of MIS-TLIF ranged in 58 MPa in L3, 52 MPa in L4 and 59 MPa in L5 and the open TLIF ranged in 50 MPa in L3, 43 MPa in L4, 49 MPa in L5 in the left axial rotation direction; The von Mises stress of screw of MIS-TLIF ranged in 54 MPa in L3, 49 MPa in L4 and 54 MPa in L5 and the open TLIF ranged in 50 MPa in L3, 43 MPa in L4, 49 MPa in L5 in the right axial rotation direction. When the number of segments increased, the pressure difference between MIS-TLIF and open TLIF increased (Figure 7 and Supplementary table 1)

FIGURE 5
www.frontiersin.org

Figure 5. The procedure of two kinds of TLIF simulation and establishment of postoperative FE model. (A) Schematic diagram of 2-level smile-face surgery: positive view; (B) Schematic diagram of 2-level smile-face surgery: lateral view; (C) Schematic diagram of 2-level open TLIF surgery: positive view; (D) Schematic diagram of 2-level open TLIF surgery: lateral view; (E) Schematic diagram of 3-level smile-face surgery: positive view; (F) Schematic diagram of 3-level smile-face surgery: lateral view; (G) Schematic diagram of 3-level open TLIF surgery: positive view; (H) Schematic diagram of 3-level open TLIF surgery: lateral view; (I) vertical view of bullet cage.

FIGURE 6
www.frontiersin.org

Figure 6. The stress value of screw systems in two kinds of 3-level model under different conditions.

FIGURE 7
www.frontiersin.org

Figure 7. The stress value of screw systems in two kinds of 2-level model under different conditions.

Changes in ROM according to lumbar interbody fusion model

The changes in the angles of axial rotation, flexion-extension, and lateral bending of two model under the same load were compared, and all two models had a stable structure under normal physiological load. Under the normal physiological load condition, the angles of movement in the directions of flexion, extension, lateral bending, and axial rotation of two kinds of fusion were then recorded. In the 3-level model, the overall angle of MIS-TLIF is 0.39 and open TLIF is 0.32 in the flexion direction; The overall angle of MIS-TLIF is 0.36 and open TLIF is 0.25 in the extension direction; The overall angle of MIS-TLIF is 0.17 and open TLIF is 0.14 in the lateral bending direction; The overall angle of MIS-TLIF is 0.21 and open TLIF is 0.2 in the axial rotation direction (Table 6). In the 2-level model, the overall angle of MIS-TLIF is 0.23 and open TLIF is 0.18 in the flexion direction; The overall angle of MIS-TLIF is 0.24 and open TLIF is 0.2 in the extension direction; The overall angle of MIS-TLIF is 0.18 and open TLIF is 0.16 in the lateral bending direction; The overall angle of MIS-TLIF is 0.19 and open TLIF is 0.17 in the axial rotation direction (Table 7).

TABLE 6
www.frontiersin.org

Table 6. Range of motion in 3-level model.

TABLE 7
www.frontiersin.org

Table 7. Range of motion in 2-level model.

Discussion

Lumbar fusion surgery is an effective surgical procedure for the treatment of spinal degenerative disorders (1). Since the introduction of PLIF by Cloward (2, 3) in 1952, new techniques have been developed to accomplish lumbar interbody fusion. In 1982, TLIF, an alternative to PLIF, was introduced for the treatment of spinal degenerative diseases that necessitated interbody fusions (4). TLIF provides a more lateral surgical approach for the space of lumbar disc to reduce the retraction of dural sac and nerve root, and to avoid the postoperative midline scar that hinders the identification of neural structures in revision patients and confers the lowest post-operative disability. The clinical outcomes of open TLIF or PLIF surgery have been good, but several studies reported that the muscle damage from subperiosteal curettage affected clinical prognosis adversely (14, 15). Wiltse (16) described a paraspinal sacrospinalis muscle-splitting approach to the lumbar spine, which reduced bleeding and provided a direct route to the transverse processes and pedicle. Compared with traditional midline incisions, this technique was thought to reduce postoperative pain and avoid rupture of the supraspinous ligament and interspinous ligament. Since Foley (17, 18) proposed the Wiltse approach for MIS-TLIF, many scholars have reported its significant advantages over open PLIF and TLIF (1921).

Advances in MIS-TLIF have led to two predominant approaches: mini-open with expandable tubular retractor through a bilateral Wiltse approach, and minimally invasive surgery using one non-expandable or expandable tubular retractor and bilateral percutaneous screw placements, which is performed for fusions of 1 or 2 segments (22). Unilateral pedicle screw fixation for MIS-TLIF is widely used to treat single-level LDD (23). Currently there is no optimal minimally invasive treatment strategy for multi-segmental LDDs. Unilateral pedicle screw fixation or plus transarticular screws might not supply enough biomechanical stability for MIS-TLIF in multi-segmental fusion. Contralateral percutaneous pedicle screw fixation (PPS) guided by C-arm for all involved vertebrae could increase the incision number, radiological exposure, operative duration and difficulty of rod installation. Therefore, we designed a contralateral bridge Freehand MIPS combined with unilateral MIS-TLIF for bilateral neurological decompression to treat multi-segmental (2- or 3-level) LDDs. The results showed that the VAS score of leg pain was significantly reduced during follow-up (P < 0.01) and the ODI was significantly reduced 5 years after surgery (P < 0.01) compared with preoperative values, which is similar to the clinical outcomes of open TLIF.

During the unilateral MIS-TLIF of this study, the normal pedicle screws are placed at the decompression side into all involved vertebrae through a paramedian muscle-splitting approach, which can provide a direct access to pedicles resulting in the incision shortened. In open TLIF, a longer midline incision is needed for the insertion of pedicle screws (4.2 ± 1.7 cm vs. 8.3 ± 2.4 cm in 2-level, 6.1 ± 2.2 cm vs. 12.3 ± 3.6 cm in 3-level). In MIS-TLIF group, the two pedicle screws are needed to be inserted into the upper and lower end vertebrae when performing contralateral bridge Freehand MIPS, and the rods are placed on the pedicle screws through subcutaneous soft tissues and muscles. Freehand MIPS is used to insert the pedicle screws into the vertebrae through Wiltse approach in a mini-incision under direct vision (510). Both Freehand MIPS and unilateral MIS-TLIF could protect the attachments of paraspinous musculature to spinal processes and the natural posterior tension band including the supraspinous and interspinous ligaments (17, 18). The use of a tubular retraction system in unilateral MIS-TLIF preserves healthy muscle tissue and further decreases damage to the ipsilateral paraspinous musculature (24). Although this procedure requires the removal of a complete unilateral facet joint, it is possible to obtain the decompression of bilateral nerves and preserve the integrity of contralateral facet joints. All these can help reducing the intraoperative bleeding and postoperative pain. In our research, the blood loss of MIS-TLIF (235.3 ± 20.1 in 2-level, 312.4 ± 30.6 in 3-level) was significantly lower than that in open TLIF (411.5 ± 31.2 in 2-level, 530.2 ± 45.3 in 3-level). MIS-TLIF group showed earlier drainage removal and shorter hospital stay than open TLIF. In some patients of open TLIF, the delayed time to pull out the drainage tube and catheter leaded to urinary tract infection. The VAS of low back in MIS-TLIF group was significantly lower than that in open TLIF group within 3 months follow-up. Some patients treated by open TLIF had intractable low back pain.

In MIS-TLIF, the unilateral facetectomy provides a complete exposed field of far-lateral aspect of intervertebral disc space, so that little retraction of thecal sac and/or nerve roots is required when preparing the intervertebral disc space and placing the cage (25). The retraction of neural elements is unilateral and minimal, significantly decreasing the risk of neurologic injury and dura tear caused by traction. In addition, pedicle screw fixation has some risks because it can cause nerve injury (26). In Freehand MIPS, the pedicle must be carefully probed in all four quadrants to ensure that a solid tube of bone exists and that violation into the inferiorly neuroforamen or into the spinal canal does not occur before the pedicle screws are implanted into the vertebrae under direct vision. This measure is taken to guarantee the safety of surgery and avoid neurologic deficits without dependence on fluoroscopy. In this study there were no serious neurologic complications, and postoperative radiography and scanning images showed that the screws and cages were correctly positioned, which confirmed the safety of smile-face surgery. Compared with percutaneous pedicle screw fixation (PPS), Freehand MIPS requires a surgical incision of similar size, but has some advantages including less intraoperative fluoroscopy monitoring and easier manipulation during surgery. Either cannulated pedicle screws or common pedicle screws can be used in Freehand MIPS, whereas only cannulated screws are used for PPS. Bridge fixation of Freehand MIPS with two pedicle screws for two end vertebrae allows the rapid installation of pedicle screws and easy implantation of rod compared with contralateral pedicle screw fixation for all involved vertebrae.

According to the follow-up result of imaging, there was no significant difference in the postoperative DH, SLA, and LLA between MIS-TLIF and open TLIF. Fusion rate was 99% (100/101) in MIS-TLIF and 97% (84/86) in open TLIF at 5-year follow-up and there was no instrumentation failure such as loosening or fracture of screws and rods. The fusion rate of MIS-TLIF is not less than that in open TLIF. This finding verified that sufficient biomechanical stability was achieved by contralateral bridge Freehand MIPS combined with unilateral MIS-TLIF. With simulation, veracity and repeatability, the finite element analysis has been viewed as a reliable approach for evaluating the biomechanical behavior of different internal fixation system, which is comparable with traditional cadaver research. We can get the same results as the cadaver model by simulating the biomechanical experiment with finite element analysis. Here, we carry out a FE analysis and a series of model measurement researches to unveil the biomechanical difference between two fusion methods. In TLIF pedicle screws fixation is the main force for stable lumbar reconstruction, but there are some postoperative problems mainly including loosening and breakage of screws. For evaluating the stress of pedicle screws fixation system, flexion, extension, left axial rotation and right axial rotation are important working conditions that cause stress concentration (27). The difference in the position and number of pedicle screws is the main reason for the difference in stress distribution (28, 29). Different number and direction will change the distribution of stress of pedicle screws and rods, resulting in screw fracture and loosening. The stress in pedicle screws tends to be concentrated on the end of thread at the tail of screw, so screw breakage often occurs here (30). Flexion and extension after posterior lumbar surgery remain the most dangerous condition (31). In the model of flexion and extension of this study, bridge fixation did not significantly increase the stress of pedicle screws compared with open-TLIF. During axial rotation, the upper and lower screw stress of bridge fixation increased more than those of open-TLIF. The reason may be that during axial rotation, the fully fixed side was taken as the center of rotation, and the incomplete fixed side needed to bear more torque. But axial rotation is not the main direction of motion in the lumbar spine. What's more, the stress distribution on the screw during axial rotation and lateral bending is also significantly less than that during lumbar flexion and extension, so the increase in stress during axial rotation does not significantly affect the overall fixation. The finite element analysis of this study supports that there is no significant difference in biomechanical stability between two kinds of fusion.

Various factors may decrease the direct and indirect costs of smile-face surgery for multi-level LDDs. Compared with contralateral pedicle screw fixation for all involved levels, bridge fixation reduces the number of pedicle screws used and implantation fees. Less blood loss can avoid the need for blood transfusion during the procedure, which might also decrease the cost of patient (32). The less postoperative pain might also lower the cost of analgesics. This type of MIS-TLIF intervention may result in a shorter length of hospitalization and lower complication rates (33), which might reduce the utilization of hospital resources. In addition, the faster recovery rate suggests that MIS-TLIF patients do not need long-time inpatient rehabilitation after surgery, further reducing the overall cost. Finally, a rapid return to work and productivity means lower indirect costs to the patient and society.

Limitation

1. Smile-face surgery is a technically demanding procedure that has a learning curve. Good outcomes can be achieved if the surgeons have prior experience in open TLIF. As the surgical technique matures, the complication rate significantly decreases.

2. This study was a retrospective analysis, so there might be some bias in the selection of cases. When some patients had very severe spinal stenosis on imaging, the surgeon would more likely to use open TLIF. Due to severe spinal stenosis resulting in adhesion of dura and ligamentum flavum, lamina, the dura was easy to tear during the removal of lamina.

3. Normal physiological loads were applied to the model without destructive or excessive loads in the finite element analysis. The results of this study are not applicable if the patient has undergone excessive exercise (overload) or trauma (destructive load).

Conclusions

The contralateral bridge Freehand MIPS combined with unilateral MIS-TLIF (smile-face surgery) has advantages over open TLIF including smaller aggression, less blood loss, and lower cost, indicating that it is a good choice of treatment for multi-segmental LDDs. Both methods can achieve good biomechanical stability. This has a certain reference value for currently popular technique: multi-segmental percutaneous endoscopic TLIF (PE-TLIF).

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author/s.

Ethics statement

The studies involving human participants were reviewed and approved by This study was approved by the Medical Ethics Committee of Zhongshan Hospital Fudan University (B2015–047). The patients/participants provided their written informed consent to participate in this study. Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article.

Author contributions

ZYK and ZTY involved in making the conception and design of research and carried out drafting of the article. GYT had the conception and design of study, and made the revision, final approval and guarantor of manuscript. ZTY and CW carried out the acquisition of data. ZL and WYC made a final approval contributed on collecting parents’ information. All authors contributed to the article and approved the submitted version.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fsurg.2022.1049260/full#supplementary-material.

References

1. Kaiser MG, Eck JC, Groff MW, Ghogawala Z, Watters WC, Dailey AT, et al. Guideline update for the performance of fusion procedures for degenerative disease of the lumbar spine. Part 17: bone growth stimulators as an adjunct for lumbar fusion. J Neurosurg Spine. (2014) 21(1):133–9. doi: 10.3171/2014.4.SPINE14326

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Reid PC, Morr S, Kaiser MG. State of the union: a review of lumbar fusion indications and techniques for degenerative spine disease. J Neurosurg Spine. (2019) 31(1):1–14. doi: 10.3171/2019.4.SPINE18915

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Xue H, Tu Y, Cai M. Comparison of unilateral versus bilateral instrumented transforaminal lumbar interbody fusion in degenerative lumbar diseases. Spine J. (2012) 12(3):209–15. doi: 10.1016/j.spinee.2012.01.010

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Yu B, Zhang J, Pan J, Wang Y, Chen Y, Zhao W, et al. Psychological and functional comparison between minimally invasive and open transforaminal lumbar interbody fusion for single-level lumbar spinal stenosis. Orthop Surg. (2021) 13(4):1213–26. doi: 10.1111/os.12986

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Gu YT, Zhang F, Jiang XX, Jia LS, McGuire R. Minimally invasive pedicle screw fixation combined with percutaneous vertebroplasty in the surgical treatment of thoracolumbar osteoporosis fracture. J Neurosurg Spine. (2013) 18(6):634–40. doi: 10.3171/2013.3.SPINE12827

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Gu YT, Zhu DH, Liu HF, Zhang F, McGuire R. Minimally invasive pedicle screw fixation combined with percutaneous vertebroplasty for preventing secondary fracture after vertebroplasty. J Orthop Surg Res. (2015) 10:31. doi: 10.1186/s13018-015-0172-1

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Li CB, Pan JF, Gu YT, Dong J. Minimally invasive pedicle screw fixation combined with percutaneous vertebroplasty for the treatment of thoracolumbar burst fracture. Int J Surg. (2016) 36(Pt A):255–60. doi: 10.1016/j.ijsu.2016.11.003

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Gu YT, Dong J, Jiang XX, Wang YC. Minimally invasive pedicle screws fixation and percutaneous vertebroplasty for the surgical treatment of thoracic metastatic tumors with neurologic compression. Spine (Phila Pa 1976). (2016) 41(Suppl 19):B14–22. doi: 10.1097/BRS.0000000000001811

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Fan WS, Zhou TY, Li JH, Sun YF, Gu YT. Freehand minimally invasive pedicle screw fixation and minimally invasive decompression for a thoracic or lumbar vertebral metastatic tumor from hepatocellular carcinoma. Front Surg. (2021) 8:723943. doi: 10.3389/fsurg.2021.723943

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Fan WS, Yang GL, Zhou TY, Chen YC, Gao ZC, Zhou WL, et al. One-stage freehand minimally invasive pedicle screw fixation combined with mini-access surgery through OLIF approach for the treatment of lumbar tuberculosis. J Orthop Surg Res. (2022) 17(1):242. doi: 10.1186/s13018-022-03130-4

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Bridwell KH, Lenke LG, McEnery KW, Baldus C, Blanke K. Anterior fresh frozen structural allografts in the thoracic and lumbar spine. Do they work if combined with posterior fusion and instrumentation in adult patients with kyphosis or anterior column defects. Spine (Phila Pa 1976). (1995) 20(12):1410–8. doi: 10.1097/00007632-199506020-00014

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Knox JB, Dai JM 3rd, Orchowski J. Osteolysis in transforaminal lumbar interbody fusion with bone morphogenetic protein-2. Spine (Phila Pa 1976). (2011) 36(8):672–6. doi: 10.1097/BRS.0b013e3181e030e0

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Yamamoto I, Panjabi MM, Crisco T, Oxland T. Three-dimensional movements of the whole lumbar spine and lumbosacral joint. Spine (Phila Pa 1976). (1989) 14(11):1256–60. doi: 10.1097/00007632-198911000-00020

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Gejo R, Matsui H, Kawaguchi Y, Ishihara H, Tsuji H. Serial changes in trunk muscle performance after posterior lumbar surgery. Spine (Phila Pa 1976). (1999) 24(10):1023–8. doi: 10.1097/00007632-199905150-00017

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Datta G, Gnanalingham KK, Peterson D, Mendoza N, Neill K, Dellen J, et al. Back pain and disability after lumbar laminectomy: is there a relationship to muscle retraction. Neurosurgery. (2004) 54(6):1413–20; discussion 1420. doi: 10.1227/01.NEU.0000124751.57121.A6

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Wiltse LL, Bateman JG, Hutchinson RH, Nelson WE. The paraspinal sacrospinalis-splitting approach to the lumbar spine. J Bone Joint Surg Am. (1968) 50(5):919–26. doi: 10.2106/00004623-196850050-00004

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Foley KT, Lefkowitz MA. Advances in minimally invasive spine surgery. Clin Neurosurg. (2002) 49:499–517.12506566

PubMed Abstract | Google Scholar

18. Foley KT, Holly LT, Schwender JD. Minimally invasive lumbar fusion. Spine (Phila Pa 1976). (2003) 28(15 Suppl):S26–35. doi: 10.1097/01.BRS.0000076895.52418.5E

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Vazan M, Gempt J, Meyer B, Buchmann N, Ryang YM. Minimally invasive transforaminal lumbar interbody fusion versus open transforaminal lumbar interbody fusion: a technical description and review of the literature. Acta Neurochir (Wien). (2017) 159(6):1137–46. doi: 10.1007/s00701-017-3078-3

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Zhao Y, Zhu Y, Zhang H, Wang C, He S, Gu G. Comparison of bilateral versus unilateral decompression incision of minimally invasive transforaminal lumbar interbody fusion in two-level degenerative lumbar diseases. Int Orthop. (2018) 42(12):2835–42. doi: 10.1007/s00264-018-3974-z

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Bredow J, Meyer C, Oikonomidis S, Kernich C, Kernich N, Hofstetter C, et al. Long-term radiological and clinical outcome after lumbar spinal fusion surgery in patients with degenerative spondylolisthesis: a prospective 6-year follow-up study. Orthop Surg. (2022) 14(8):1607–14. doi: 10.1111/os.13350

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Qin R, Liu B, Zhou P, Yao Y, Hao J, Yang K, et al. Minimally invasive versus traditional open transforaminal lumbar interbody fusion for the treatment of single-level spondylolisthesis grades 1 and 2: a systematic review and meta-analysis. World Neurosurg. (2019) 122:180–9. doi: 10.1016/j.wneu.2018.10.202

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Chen C, Cao X, Zou L, Hao G, Zhou Z, Zhang G. Minimally invasive unilateral versus bilateral technique in performing single-segment pedicle screw fixation and lumbar interbody fusion. J Orthop Surg Res. (2015) 10:112. doi: 10.1186/s13018-015-0253-1

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Hiyama A, Katoh H, Sakai D, Tanaka M, Sato M, Watanabe M. Short-term comparison of preoperative and postoperative pain after indirect decompression surgery and direct decompression surgery in patients with degenerative spondylolisthesis. Sci Rep. (2020) 10(1):18887. doi: 10.1038/s41598-020-76028-y

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Berkman RA, Wright AH, Khan I, Sivaganesan A. Perioperative modifications to the open TLIF provide comparable short-term outcomes to the MIS-TLIF. Clin Spine Surg. (2022) 35(1):E202–10. doi: 10.1097/BSD.0000000000001181

PubMed Abstract | CrossRef Full Text | Google Scholar

26. El-Desouky A, Silva PS, Ferreira A, Wibawa GA, Vaz R, Pereira P. How accurate is fluoroscopy-guided percutaneous pedicle screw placement in minimally invasive TLIF. Clin Neurol Neurosurg. (2021) 205:106623. doi: 10.1016/j.clineuro.2021.106623

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Fan W, Guo LX, Zhao D. Posterior lumbar interbody fusion versus transforaminal lumbar interbody fusion: finite element analysis of the vibration characteristics of fused lumbar spine. World Neurosurg. (2021) 150:e81–8. doi: 10.1016/j.wneu.2021.02.094

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Guvenc Y, Akyoldas G, Senturk S, Erbulut D, Yaman O, Ozer AF. How to reduce stress on the pedicle screws in thoracic spine importance of screw trajectory: a finite element analysis. Turk Neurosurg. (2019) 29(1):20–5. doi: 10.5137/1019-5149.JTN.21895-17.2

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Song M, Zhang Z, Lu M, Zong J, Dong C, Ma K. Four lateral mass screw fixation techniques in lower cervical spine following laminectomy: a finite element analysis study of stress distribution. Biomed Eng Online. (2014) 13:115. doi: 10.1186/1475-925X-13-115

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Pape D, Adam F, Fritsch E, Müller K, Kohn D. Primary lumbosacral stability after open posterior and endoscopic anterior fusion with interbody implants: a roentgen stereophotogrammetric analysis. Spine (Phila Pa 1976). (2000) 25(19):2514–8. doi: 10.1097/00007632-200010010-00014

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Han Z, Ren B, Zhang L, Mao C, Liu J, Li J, et al. Finite element analysis of a novel fusion strategy in minimally invasive transforaminal lumbar interbody fusion. Biomed Res Int. (2022) 2022:4266564. doi: 10.1155/2022/4266564

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Deng WW, Lan M, Peng AF, Chen T, Li ZQ, Liu ZL, et al. The risk factors for postoperative ileus following posterior thoraco-lumbar spinal fusion surgery. Clin Neurol Neurosurg. (2019) 184:105411. doi: 10.1016/j.clineuro.2019.105411

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Jenkins NW, Parrish JM, Hrynewycz NM, Brundage TS, Singh K. Complications following minimally invasive transforaminal lumbar interbody fusion: incidence, independent risk factors, and clinical impact. Clin Spine Surg. (2020) 33(5):E236–40. doi: 10.1097/BSD.0000000000000933

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: lumbar degenerative disease, multi-segment, transforaminal lumbar interbody fusion, pedicle screw fixation, minimally invasive surgery

Citation: Zhang Y, Zhou T, Gu Y, Che W, Zhang L and Wang Y (2022) Contralateral bridge fixation of freehand minimally invasive pedicle screws combined with unilateral MIS-TLIF vs. open TLIF in the treatment of multi-segmental lumbar degenerative diseases: A five years retrospective study and finite element analysis. Front. Surg. 9:1049260. doi: 10.3389/fsurg.2022.1049260

Received: 20 September 2022; Accepted: 14 October 2022;
Published: 2 November 2022.

Edited by:

Qingquan Kong, Sichuan University, China

Reviewed by:

Alessandro Gasbarrini, Rizzoli Orthopedic Institute (IRCCS), Italy
Zhang Qiang, Capital Medical University, China
YM Xi, The Affiliated Hospital of Qingdao University, China

© 2022 Zhang, Zhou, Gu, Che, Zhang and Wang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Yutong Gu NDQ3NTc0MzEzQHFxLmNvbQ==

These authors have contributed equally to this work

Specialty Section: This article was submitted to Orthopedic Surgery, a section of the journal Frontiers in Surgery

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.