Skip to main content

ORIGINAL RESEARCH article

Front. Surg., 06 January 2023
Sec. Orthopedic Surgery
This article is part of the Research Topic The Clinical Related Research in the Field of Cervical Spine View all 16 articles

The predictive value of Hounsfield units for titanium mesh cage subsidence after anterior cervical corpectomy and fusion

\r\nHaimiti Abudouaini&#x;Haimiti AbudouainiTingkui Wu&#x;Tingkui WuHao Liu
Hao Liu*Beiyu WangBeiyu WangHua Chen\r\nHua Chen
  • Department of Orthopedic Surgery, West China Hospital, Sichuan University, Chengdu, China

Objective: To investigate whether bone mineral density (BMD) measured in Hounsfield units (HUs) correlates with titanium mesh cage (TMC) subsidence after anterior cervical corpectomy and fusion (ACCF).

Methods: A total of 64 patients who underwent one or two levels of ACCF with TMC with a mean follow-up of 19.34 ± 7.86 months were analysed. HU values were measured three times in 3 different planes in the upper and lower vertebrae according to published methods. Subsidence was defined as segmental height loss of more than 3 mm. Pearson correlation analysis was performed. Receiver operating characteristic (ROC) curve analysis was used to obtain optimal thresholds. A multivariate logistic regression analysis was also conducted.

Results: Twenty-two patients (34.38%) had evidence of TMC subsidence on follow-up x-ray. The mean HU values in the subsidence group (317.34 ± 32.32, n = 22) were significantly lower than those in the nonsubsidence group (363.07 ± 25.23 n = 42, p < 0.001, t test). At last follow-up, mean disc height loss was 4.80 ± 1.16 mm in the subsidence group and 1.85 ± 1.14 mm in the nonsubsidence group (p < 0.001). There was a negative correlation between HU values and disc height loss (Pearson's coefficient −0.494, p < 0.001). HU values decreased gradually from the C3 vertebra to the C7 vertebra, and the HU values of the C5, C6, and C7 vertebrae in the nonsubsidence group were significantly higher than those in the subsidence group (p < 0.05). Furthermore, there were significant differences between the groups in the segmental angle at the last follow-up and the mean changes in segmental angle (p < 0.05). The area under the ROC curve was 0.859, and the most appropriate threshold of the HU value was 330.5 (sensitivity 100%, specificity 72.7%). The multivariate logistic regression analysis showed that older age (p = 0.033, OR = 0.879), lower LIV HU value (p < 0.001, OR = 1.053) and a greater segmental angle change (p = 0.002, OR 6.442) were significantly associated with a higher incidence of TMC subsidence after ACCF.

Conclusion: There are strong correlations between a lower HU value and TMC subsidence after ACCF. More accurate assessment of bone quality may be obtained if HU measurement can be used as a routine preoperative screening method together with DXA. For patients with HU values <330.5, a more comprehensive and cautious preoperative plan should be implemented to reduce TMC subsidence.

Introduction

Reconstruction of the cervical spine with titanium mesh cages (TMCs) has been widely used in anterior cervical corpectomy and fusion (ACCF) (1, 2). Although many previous studies report satisfactory decompression, rapid stabilization and a relatively high fusion rate (ranging from 95% to 100%) (3), subsidence of the TMC is a major concern before implementing ACCF. Indeed, cage subsidence after ACCF may lead to ligamentum flavum wrinkles and neural foramen stenosis, segmental instability, non-union, or postoperative kyphosis, with some patients even requiring revision surgery (4, 5).

Several papers have reported a close relationship between bone mineral density (BMD) and postoperative cage subsidence in both the lumbar and cervical spines (68). The DXA (dual-energy x-ray absorptiometry) technique is widely used to evaluate preoperative bone quality before spinal surgery. DXA assesses BMD by measuring the T-score of both hips and waist 1–4 to represent the whole-body bone quality. However, previous literature shows that measurement error may occur when evaluating the bone mass of spine vertebra using DXA examination (911). Moreover, there is still insufficient evidence to prove the accuracy of assessing the bone mass of the cervical vertebrae with T-score measured in the hip bone and lumbar spine. Although local trabecular BMD can be accurately obtained through quantitative CT (QCT) (12), the popularity of QCT remains very low in China and is also costly.

Several studies have found that Hounsfield units (HU) measured by CT are associated with cage subsidence after lumbar surgery (1315). To the best of our knowledge, there are few reports on the relationship between TMC subsidence and HU values in ACCF (16). Therefore, in this study, we sought to determine associations between preoperative CT HU and post-ACCF TMC subsidence and to identify patients who are at high risk for severe subsidence.

Materials and methods

Study population and criteria

Patients who underwent single- and two-level ACCF using a titanium mesh cage (Medtronic Sofamor Danek) from March 2011 to December 2019 were included. All surgeries were performed by one surgeon. The study's indication for ACCF included posterior osteophytes of the vertebrae, ossified posterior longitudinal ligament (OPLL) and prolapse of the free nucleus pulposus between the C3/4 and C6/7 levels that did not respond to conservative treatment for at least 6 weeks or resulted in progressive symptoms of nerve root/spinal cord compression. All patients were followed up clinically and radiographically for a minimum of 12 months. Patients undergoing anterior cervical discectomy and fusion (ACDF), revision surgery and history of surgery, trauma or tumor at the C1–C7 level, and severe osteoporosis (T-score ≤−2.5), Patients with endplate injury were excluded. Besides, patients with lack of clinical and radiological data or lost follow-up were also excluded and patients only with complete clinical, radiological, and follow-up data were included.

Surgical procedure

After general anesthesia, the patient was maintained in the supine position with the neck slightly extended. The Smith-Robinson approach was used in all cases. After the intervertebral space was expanded, discectomy and removal of vertebral bodies were performed, and autologous bone was applied as bone graft material. Then, the osteophytes and posterior longitudinal ligament were removed, and the endplate was carefully prepared. After adequate decompression, a TMC with an appropriate size was selected and filled with autologous bone fragments. The TMC was then inserted into the corpectomy defect, and fluoroscopy was used to confirm the cage location. Last, a suitably sized anterior cervical locking plate system was used in all cases for further stabilization. After surgery, all patients were advised to wear a soft neck collar for 6 weeks.

Radiographic evaluation

HU was measured at vertebrae above and below the titanium mesh cage placement (e.g., C4 ACCF had C3 and C5 vertebral bodies measured for HU). The measurement method proposed by Schreiber et al. (17) was used to evaluate the vertebral body HU values. The HU value was measured three times in the upper and lower vertebrae by selecting the elliptical region of interest (ROI) on sagittal, mid-coronal and mid-axial plane CT image reconstruction, and the average value was defined as the final HU (Figure 1A). The connecting line between the midpoint of the upper endplate of the upper vertebra and the midpoint of the lower endplate of the lower vertebra was defined as the disc height (Figure 1B). Disc height measurements were recorded before surgery, at the initial postoperative radiograph (within 7 days after surgery) and at the final follow-up; the difference between the last follow-up and initial postoperative disc height was defined as the loss in disc height. Subsidence was defined as a disc height loss >3 mm or TMC migration (angular deviation >3 degrees in lateral and AP plane) into the endplate at the final follow-up (4). The C2–7 angle was the angle between the caudal margin of C2 and the caudal margin of C7 at the neutral position. The segmental angle was the angle formed by lines drawn at the cranial margin of the superior vertebral body and at the caudal margin of the inferior body (Figure 2). Solid bone fusion was defined as the establishment of a solid bone bridge between fusion segments on the last follow up reconstructed CT scans.

FIGURE 1
www.frontiersin.org

Figure 1. Measurement method of the HU value in C5 ACCF. (A) First, HU values of the C4 vertebral body were calculated. The HU values of the mid-sagittal (A1,A2), mid-coronal (A3,A4), and mid-axial (A5,A6) planes were measured. The same method was used to calculate the HU values of the C6 vertebral body. (B) Illustration of the method for measuring disc height. Disc height was defined as the straight line between the midpoint of the lower endplate of the upper vertebra and the midpoint of the upper endplate of the lower vertebra. Disc height was measured before surgery (B1) and within 3 days after surgery (B2) and at the final follow-up (B3). This patient was assessed to have subsidence due to height loss greater than 3 mm at the final follow-up (1.5 years after surgery).

FIGURE 2
www.frontiersin.org

Figure 2. Measurement method of the global and segmental cervical curvature. The C2–7 angle was defined as the angle between the caudal margin of C2 and the caudal margin of C7 in a neutral position. The segmental angle was defined as the angle formed by lines drawn at the cranial margin of the upper instrumented vertebral body and the caudal margin of the lower instrumented vertebral body.

To reduce measurement errors, an independent panel of radiologists was established in our study. The panel consisted of three study-blinded radiologists. Among them, two radiologists were responsible for data collection while the remaining one was responsible for data analysis. In case differences between the first two collected sets of data were relatively large (e.g., more than 10 HU value, 2 degrees or 2 mm), the third radiologist was responsible for confirmative remeasuring.

Statistical methods

All statistical analyses were performed using SPSS 25.0 software (SPSS Inc., Chicago, IL, USA). Continuous data are presented as the mean ± standard deviation. Independent t tests were used to detect differences, including HU values and disc height, between patients with and without TMC subsidence. Chi-square analysis and Fisher's exact test were applied to assess differences between groups for categorical variables. Correlations were analysed using Pearson correlation. The optimal cut-offs of the HU value were established using a receiver operating characteristic (ROC) curve, and the area under the curve (AUC) was calculated. The maximum Youden index was used to determine the optimal cut-off value of Hounsfield units. Patients were classified according to the HU threshold value, as determined by ROC curve analysis. A multivariate logistic regression analysis was also conducted. For all statistical analyses, 95% confidence intervals were obtained; p < 0.05 (two-sided) was the criterion for statistical significance.

Results

A total of 64 patients met the inclusion criteria (Table 1). All patients were followed up for at least 1 year (mean 19.34 ± 7.86 months). Of the 64 patients, 22 (34.38%) developed TMC subsidence, and 42 were classified into the nonsubsidence group. There were no significant differences in sex, BMI, level number or distribution, T-score between the subsidence and nonsubsidence groups (Table 2). The average age in the subsidence group was 55.85 ± 9.43 and 48.95 ± 9.54 years in nonsubsidence group. The average age in subsidence group was significantly higher than the average age in nonsubsidence group (p = 0.017). The mean HU value in the subsidence group was 317.34 ± 32.32, which was significantly lower than the mean HU value of the nonsubsidence group, at 363.07 ± 25.23 (p < 0.001; Table 2). The mean height loss in the nonsubsidence and subsidence groups was 1.85 ± 1.14 and 4.80 ± 1.16 mm, respectively (p < 0.001; Table 2).

TABLE 1
www.frontiersin.org

Table 1. Preoperative information and disc height of the patients.

TABLE 2
www.frontiersin.org

Table 2. Preoperative information and HU between patients with and patients without subsidence.

Pearson correlation analysis revealed a significant negative correlation between preoperative HU values and postoperative disc height loss (r = −0.494, p < 0.001; Figure 3). HU values decreased gradually from the C3 vertebra to the C7 vertebra, and the HU values of the C5, C6, and C7 vertebrae in the nonsubsidence group were significantly higher than those in the subsidence group (p < 0.05, Table 3). Furthermore, there were no significant differences in global cervical curvature between the 2 groups (p > 0.05, Table 4). In the nonsubsidence group, the segmental angle was improved from 1.63 ± 2.01° before surgery to 3.26 ± 2.03° at the last follow-up, with a mean change value of −0.15 ± 0.60°. In the subsidence group, it decreased from 1.67 ± 2.78° before surgery to −1.19 ± 4.10 at the last follow-up, and the mean change value was −3.73 ± 3.53. There were significant differences between the groups in the segmental angle at the last follow-up and the mean changes in segmental angle (p < 0.001) (Table 4).

FIGURE 3
www.frontiersin.org

Figure 3. Linear correlation (black line) between HU and the TMC subsidence correlation coefficient (r) at the overall cervical vertebrae. Significant correlation coefficients are indicated by asterisks.

TABLE 3
www.frontiersin.org

Table 3. Mean HU values of different subaxial cervical vertebrae in patients.

TABLE 4
www.frontiersin.org

Table 4. Comparison of the global and segmental cervical curvature between the groups.

The AUC of the ROC curve was 0.859 (95% CI: 0.748–0.971; Figure 4), and the optimal cut-off was 330.5, with a sensitivity of 100% and a specificity of 72.7%. Fisher's exact test showed that patients with <330.5 HU were more prone towards TMC subsidence (p = 0.001, Table 2).

FIGURE 4
www.frontiersin.org

Figure 4. ROC curve for the sensitivity and specificity of HU values in predicting subsidence after ACCF. The AUC was 0.859.

The age, gender, surgical level, HU value of upper instrumented vertebra (UIV) and lower instrumented vertebra (LIV), T-score, segmental angle change and preoperative disc height were elected to undergo multiple logistic regression analysis. The results showed that older age (p = 0.033, OR = 0.879), lower LIV HU value (p < 0.001, OR = 1.053) and a greater segmental angle change (p = 0.002, OR 6.442) were significantly associated with a higher incidence of TMC subsidence after ACCF (Table 5).

TABLE 5
www.frontiersin.org

Table 5. Results of multivariate logistic regression.

Discussion

In this study, imaging data of 64 patients undergoing anterior cervical corpectomy with TMC fusion were retrospectively reviewed. TMC subsidence was observed in 22 (34.38%) patients in our study, which is roughly consistent with previous studies (3, 16). However, the subsidence standard varies among studies. Majority of previous articles have used the disc height loss >3mm (4, 1619) to define the TMC subsidence, whereas others have used 4 mm (20) or 2 mm (21) as a threshold. If subsidence is defined as a definite disc height loss >3 mm, then the subsidence rate of ACCF with TMC fluctuates between 12% and 80% in previous studies (35, 17, 22). To the best of our knowledge, there is no consensus in the literature regarding an accurate relationship between TMC subsidence and clinical outcomes. For example, Chen et al. (4) reported that 7% of single-level and 12% of two-level patients with corpectomy developed TMC subsidence, which might have led to poor clinical results and related complications. However, Ji et al. (16) reported that TMC subsidence does not negatively affect the clinical outcomes after ACCF. Nevertheless, nearly all authors agree that low BMD or osteoporosis is an important element causing TMC subsidence. Hence, accurate evaluation of bone quality at the upper and lower adjacent segments seems to be very important to reduce the TMC subsidence rate after ACCF.

In most situations, DXA has been used to assess bone quality prior to performing ACCF. Although DXA is a valid and time-tested method to estimate overall bone quality, it is still unclear whether each cervical vertebra can be accurately assessed. It has been reported that some T-scores obtained by DXA are higher than the actual BMD in patients with severely degenerative spines (911). Therefore, HU has received increasing attention during the last few years, with the hope of providing more accurate information on local bone strength. Recent studies have revealed a strong correlation between HU and BMD and T-scores (2325) and between HUs and graft subsidence (2628) after spine surgery. However, most of the studies focused on lumbar surgery. To our knowledge, only one article has reported the relationship between the HU value and TMC subsidence after ACCF (16). In that study, the global cervical HU value was significantly lower in the subsidence group (315 ± 73) than in the nonsubsidence group (388 ± 64), and a global cervical HU value <333 was independently associated with TMC subsidence. Nonetheless, the HU value was measured only in axial images: just inferior to the superior endplate, mid-body, and just superior to the inferior endplate. To maximally reduce bias, we measured the HU value 3 times in three different plane; we found that a cut-off value of 330.5 was associated with subsidence and that the HU value decreased gradually from C3–C7. Wang et al. (13) also measured HU values of different subaxial cervical vertebrae before ACDF using the technique described by Schreiber et al. (the same technique was used in our study), and the HU values ranged from 326.9 ± 40.7 to 426.3 ± 61.8 in their study. They also found that a threshold of 343.7 for the HU value had a sensitivity of 77.1% and specificity of 87.5% for predicting cage subsidence after ACDF. In our study, the threshold of 330.5 had a sensitivity of 100% and specificity of 72.7% in predicting cage subsidence for predicting TMC subsidence after ACCF.

Although HU measurement had useful predictive value for both the lumbar and cervical spines, one important limitation of HU measurement in assessing bone quality is that it does not consider various endplate conditions. In fact, several studies have reported that changes in the endplate are associated with cage subsidence (29, 30), and others have reported that CT can evaluate and predict lumbar vertebral endplate mechanical properties, including osteoporosis and osteopaenia (3133). Therefore, we believe that if appropriate methods that provide more information about the strength of the endplate area in direct contact with the TMC can be added to HU measurements, the predictive value of HU may be further increased.

Lee et al. (8) also analyzed the cervical alignment and segmental angle after ACCF and found that patients with cage subsidence seemed to have significantly greater kyphotic changes than those in patients without subsidence. One different finding from our study, the both cervical alignment and segmental angle were significantly different in their study. However, in our study, a significant difference was only found in segmental angle between the groups. One possible reason is a decrease in segmental height loss during subsidence induces kyphotic changes in the segmental angle, but such changes failed to impact the global cervical curve.

Many factors affecting TMC subsidence after ACCF have been reported in the previous studies. These factors including an older patient age, more corpectomy levels, severe osteoporosis, excessive endplate removal and intraoperative over distraction (20, 29). In addition, the diameter, metal attributes of TMC and the shape of the graft also are important factors that can affect the TMC subsidence after ACCF (34). At present, researchers constantly exploring ways to prevent the subsidence of TMC from many aspects, such as the design of titanium mesh, the exploration of new materials, and surgical methods. Ren et al. (35) have found that middle part of the endplate is mostly a cystic cavity, and the edge of the endplate has the maximum strength. Therefore, endplate should not be scraping too much during the operation, and preserving the integrity of the endplate as possible for preventing postoperative TMC subsidence. Besides, due to cervical spine endplate has a certain inclination, if the TMC cannot be fully contacted to the endplate may lead to stress concentrations and TMC subsidence. Therefore, in order to increase stress dispersion, when inserting TMC during the operation, we should note that both ends of the TMC are as consistent as possible with the inclination of the surface of the endplate. Hasegawa et al. (36) have reported that a TMC with larger diameter and/or augmentation of internal end ring produces a significant increase of the interface strength between the cage and the vertebra, and their result also implies that in severe osteoporotic spine the stability of the cage is declined, and suggested that other instrumentation should be combined with TMC in severe osteoporosis. Based on your suggestion, these contents have been added to the discussion section in the revised manuscript.

Study limitations

There are some limitations of this study that should be considered. First, this was a retrospective study, and a prospective study is required to confirm the sensitivity and specificity of <330.5 HU in predicting TMC subsidence after ACCF. Second, we did not investigate clinical efficacy because many larger-sample studies have reported the relationship between TMC subsidence and clinical efficacy, which we think may be more representative (4, 16, 5, 17, 22). We did not measured the hardness of endplate in this study. One major reason is that there is currently no standardized methods of evaluate the endplate bone quality directly through Hounsfield units measured on CT. Another limitation of the study is that radiological parameters such as the position and contact area of the TMC were not discussed. This is mainly because we sought to explore the relationship between the bone quality measured by HU values and TMC subsidence, which have some differences from studies that discuss several risk factors at the same time. Besides, even though we measured these radiological parameters based on previous reports, we acknowledge that measurement error may still persists. Another limitation is the relatively small number of patients. Although we selected patients from March 2011 to December 2019, we limited the sample to only operations performed by the same doctor, and ACCF with TMC is not the type of surgery most performed by our team. Similar patients may have more opportunities to undergo multilevel ACDF, cervical disc replacement (CDR) or hybrid surgery (ACDF + CDR) by our team.

Conclusion

There are strong correlations between a lower HU value and TMC subsidence after ACCF. More accurate assessment of bone quality may be obtained if HU measurement can be used as a routine preoperative screening method together with DXA. For patients with HU values <330.5, a more comprehensive and cautious preoperative plan should be implemented to reduce TMC subsidence.

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics statement

All methods were performed in accordance with the relevant guidelines and regulations. The study was conducted after ethical approval was obtained from the West China Hospital of Sichuan University College Ethical Committee, and all the participants provided written informed consent.

Author contributions

HA and HL contributed to the design of the study. TW and BW contributed significantly to the analysis and manuscript preparation. HC helped perform the analysis with constructive discussions. All authors contributed to the article and approved the submitted version.

Funding

The research was supported by the Sichuan Province Science and Technology Support Program (grant no. 21PJ039 to TW, grant no. 2019YFQ0002 to HL, grant no. 2020YFS0084 to BW, grant no. 2019YFS0135 to HC).

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Thalgott JS, Xiongsheng C, Giuffre JM. Single stage anterior cervical reconstruction with titanium mesh cages, local bone graft, and anterior plating. Spine J. (2003) 3(4):294–300. doi: 10.1016/S1529-9430(02)00588-0

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Hee HT, Majd ME, Holt RT, Whitecloud TS 3rd, Pienkowski D. Complications of multilevel cervical corpectomies and reconstruction with titanium cages and anterior plating. J Spinal Disord Tech. (2003) 16(1):1–8. doi: 10.1097/00024720-200302000-00001

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Daubs MD. Early failures following cervical corpectomy reconstruction with titanium mesh cages and anterior plating. Spine. (2005) 30(12):1402–6. doi: 10.1097/01.brs.0000166526.78058.3c

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Chen Y, Chen D, Guo Y, Wang X, Lu X, He Z, et al. Subsidence of titanium mesh cage: a study based on 300 cases. J Spinal Disord Tech. (2008) 21(7):489–92. doi: 10.1097/BSD.0b013e318158de22

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Nakase H, Park YS, Kimura H, Sakaki T, Morimoto T. Complications and long-term follow-up results in titanium mesh cage reconstruction after cervical corpectomy. J Spinal Disord Tech. (2006) 19(5):353–7. doi: 10.1097/01.bsd.0000210113.09521

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Oh KW, Lee JH, Lee JH, Lee DY, Shim HJ. The correlation between cage subsidence, bone mineral density, and clinical results in posterior lumbar interbody fusion. Clin Spine Surg. (2017) 30(6):E683–9. doi: 10.1097/BSD.0000000000000315

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Tempel ZJ, Gandhoke GS, Okonkwo DO, Kanter AS. Impaired bone mineral density as a predictor of graft subsidence following minimally invasive transpsoas lateral lumbar interbody fusion. Eur Spine J. (2015) 24(Suppl 3):414–9. doi: 10.1007/s00586-015-3844-y

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Lee YS, Kim YB, Park SW. Risk factors for postoperative subsidence of single-level anterior cervical discectomy and fusion: the significance of the preoperative cervical alignment. Spine. (2014) 39(16):1280–7. doi: 10.1097/BRS.0000000000000400

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Ebbesen EN, Thomsen JS, Beck-Nielsen H, Nepper-Rasmussen HJ, Mosekilde L. Lumbar vertebral body compressive strength evaluated by dual-energy x-ray absorptiometry, quantitative computed tomography, and ashing. Bone. (1999) 25(6):713–24. doi: 10.1016/S8756-3282(99)00216-1

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Jergas M, Breitenseher M, Glüer CC, Black D, Lang P, Grampp S, et al. Which vertebrae should be assessed using lateral dual-energy x-ray absorptiometry of the lumbar spine. Osteoporos Int. (1995) 5(3):196–204. doi: 10.1007/BF02106100

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Masud T, Langley S, Wiltshire P, Doyle DV, Spector TD. Effect of spinal osteophytosis on bone mineral density measurements in vertebral osteoporosis. Br Med J. (1993) 307(6897):172–3. doi: 10.1136/bmj.307.6897.172

CrossRef Full Text | Google Scholar

12. Pickhardt PJ, Pooler BD, Lauder T, del Rio AM, Bruce RJ, Binkley N. Opportunistic screening for osteoporosis using abdominal computed tomography scans obtained for other indications. Ann Intern Med. (2013) 158(8):588–95. doi: 10.7326/0003-4819-158-8-201304160-00003

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Wang Q, Wang C, Zhang X, Hu F, Hu W, Li T, Wang Y, Zhang X. Correlation of vertebral trabecular attenuation in hounsfield units and the upper instrumented vertebra with proximal junctional failure after surgical treatment of degenerative lumbar disease. J Neurosurg Spine. (2020):1–8. doi: 10.3171/2020.7.SPINE20920

CrossRef Full Text | Google Scholar

14. Pisano AJ, Fredericks DR, Steelman T, Riccio C, Helgeson MD, Wagner SC. Lumbar disc height and vertebral hounsfield units: association with interbody cage subsidence. Neurosurg Focus. (2020) 49(2):E9. doi: 10.3171/2020.4.FOCUS20286

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Ullrich BW, Schenk P, Spiegl UJ, Mendel T, Hofmann GO. Hounsfield units as predictor for cage subsidence and loss of reduction: following posterior-anterior stabilization in thoracolumbar spine fractures. Eur Spine J. (2018) 27(12):3034–3042. doi: 10.1007/s00586-018-5792-9

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Ji C, Yu S, Yan N, Wang J, Hou F, Hou T, et al. Risk factors for subsidence of titanium mesh cage following single-level anterior cervical corpectomy and fusion. BMC Musculoskelet Disord. (2020) 21(1):32. doi: 10.1186/s12891-019-3036-8

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Fengbin Y, Jinhao M, Xinyuan L, Xinwei W, Yu C, Deyu C. Evaluation of a new type of titanium mesh cage versus the traditional titanium mesh cage for single-level, anterior cervical corpectomy and fusion. Eur Spine J. (2013) 22(12):2891–6. doi: 10.1007/s00586-013-2976-1

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Yang X, Chen Q, Liu L, Song Y, Kong Q, Zeng J, et al. Comparison of anterior cervical fusion by titanium mesh cage versus nano-hydroxyapatite/polyamide cage following single-level corpectomy. Int Orthop. (2013) 37:2421–7. doi: 10.1007/s00264-013-2101-4

PubMed Abstract | CrossRef Full Text | Google Scholar

19. van Jonbergen HP, Spruit M, Anderson PG, Pavlov PW. Anterior cervical interbody fusion with a titanium box cage: early radiological assessment of fusion and subsidence. Spine J. (2005) 5(6):645–9; discussion 649. doi: 10.1016/j.spinee.2005.07.007

PubMed Abstract | CrossRef Full Text | Google Scholar

20. An TY, Kim JY, Lee YS. Risk factors and radiologic changes in subsidence after single-level anterior cervical corpectomy: a minimum follow-up of 2 years. Korean J Neurotrauma. (2021) 17(2):126–35. doi: 10.13004/kjnt.2021.17.e23

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Lau D, Song Y, Guan Z, La Marca F, Park P. Radiological outcomes of static vs expandable titanium cages after corpectomy: a retrospective cohort analysis of subsidence. Neurosurgery. (2013) 72(4):529–39. doi: 10.1227/NEU.0b013e318282a558

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Bilbao G, Duart M, Aurrecoechea JJ, Pomposo I, Igartua A, Catalán G, et al. Surgical results and complications in a series of 71 consecutive cervical spondylotic corpectomies. Acta Neurochir (Wien). (2010) 152(7):1155–63. doi: 10.1007/s00701-010-0660-3

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Schreiber JJ, Anderson PA, Rosas HG, Buchholz AL, Au AG. Hounsfield units for assessing bone mineral density and strength: a tool for osteoporosis management. J Bone Joint Surg Am. (2011) 93(11):1057–63. doi: 10.2106/JBJS.J.00160

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Kim KJ, Kim DH, Lee JI, Choi BK, Han IH, Nam KH. Hounsfield units on lumbar computed tomography for predicting regional bone mineral density. Open Med. (2019) 14:545–51. doi: 10.1515/med-2019-0061

CrossRef Full Text | Google Scholar

25. Lee SJ, Binkley N, Lubner MG, Bruce RJ, Ziemlewicz TJ, Pickhardt PJ. Opportunistic screening for osteoporosis using the sagittal reconstruction from routine abdominal CT for combined assessment of vertebral fractures and density. Osteoporos Int. (2016) 27(3):1131–6. doi: 10.1007/s00198-015-3318-4

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Mi J, Li K, Zhao X, Zhao CQ, Li H, Zhao J. Vertebral body hounsfield units are associated with cage subsidence after transforaminal lumbar interbody fusion with unilateral pedicle screw fixation. Clin Spine Surg. (2017) 30(8):E1130–6. doi: 10.1097/BSD.0000000000000490

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Sakai Y, Takenaka S, Matsuo Y, Fujiwara H, Honda H, Makino T, Kaito T. Houns eld unit of screw trajectory as a predictor of pedicle screw loosening after single level lumbar interbody fusion. J Orthop Sci. (2018) 23(5):734–8. doi: 10.1016/j.jos.2018.04.006

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Schreiber JJ, Hughes AP, Taher F, Girardi FP. An association can be found between hounsfield units and success of lumbar spine fusion. HSS J. (2014) 10(1):25–9. doi: 10.1007/s11420-013-9367-3

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Lim TH, Kwon H, Jeon CH, Kim JG, Sokolowski M, Natarajan R, et al. Effect of endplate conditions and bone mineral density on the compressive strength of the graft-endplate interface in anterior cervical spine fusion. Spine. (2001) 26(8):951–6. doi: 10.1097/00007632-200104150-00021

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Agarwal N, White MD, Zhang X, Alan N, Ozpinar A, Salvetti DJ, et al. Impact of endplate-implant area mismatch on rates and grades of subsidence following stand-alone lateral lumbar interbody fusion: an analysis of 623 levels. J Neurosurg Spine. (2020):1–5.

Google Scholar

31. Silva MJ, Wang C, Keaveny TM, Hayes WC. Direct and computed tomography thickness measurements of the human, lumbar vertebral shell and endplate. Bone. (1994) 15:409–14. doi: 10.1016/8756-3282(94)90817-6

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Patel RR, Noshchenko A, Dana Carpenter R, Baldini T, Frick CP, Patel VV, Yakacki CM. Evaluation and prediction of human lumbar vertebrae endplate mechanical properties using indentation and computed tomography. J Biomech Eng. (2018) 140(10):1010111–9. doi: 10.1115/1.4040252

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Okano I, Jones C, Salzmann SN, Reisener MJ, Sax OC, Rentenberger C, et al. Endplate volumetric bone mineral density measured by quantitative computed tomography as a novel predictive measure of severe cage subsidence after standalone lateral lumbar fusion. Eur Spine J. (2020) 29(5):1131–40. doi: 10.1007/s00586-020-06348-0

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Zhang Y, Quan Z, Zhao Z, Luo X, Tang K, Li J, et al. Evaluation of anterior cervical reconstruction with titanium mesh cages versus nano-hydroxyapatite/polyamide66 cages after 1-or 2-level corpectomy for multilevel cervical spondylotic myelopathy: a retrospective study of 117 patients. PLoS One. (2014) 9:e96265. doi: 10.1371/journal.pone.0096265

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Ren X, Mei F. Anatomical structure and experimental study on biomechanical characteristics of cervical vertebral endplate. Chin J Clin Anat. (1999)(02):78–80.

Google Scholar

36. Hasegawa K, Abe M, Washio T, Hara T. An experimental study on the interface strength between titanium mesh cage and vertebra in reference to vertebral bone mineral density. Spine. (2001) 26:957–63. doi: 10.1097/00007632-200104150-00022

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: anterior cervical corpectomy and fusion, ACCF, Hounsfield units, subsidence, bone mineral density

Citation: Abudouaini H, Wu T, Liu H, Wang B and Chen H (2023) The predictive value of Hounsfield units for titanium mesh cage subsidence after anterior cervical corpectomy and fusion. Front. Surg. 9:1012364. doi: 10.3389/fsurg.2022.1012364

Received: 5 August 2022; Accepted: 1 November 2022;
Published: 6 January 2023.

Edited by:

Fuxin Wei, Sun Yat-sen University, China

Reviewed by:

Plauto Christopher A. Watanabe, University of São Paulo, Brazil
Zhonghai Li, First Affiliated Hospital of Dalian Medical University, China
Xiaoji Luo, Chongqing Medical University, China

© 2023 Abudouaini, Wu, Liu, Wang and Chen. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Hao Liu liuhaospine@163.com

These authors share first authorship

Specialty Section: This article was submitted to Orthopedic Surgery, a section of the journal Frontiers in Surgery

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.