The validity and reliability of a hydraulic resistance device for assessing resisted sprint time

\r\nMatic Sa&#x;ekMatic Sašek1Oskar Cvjeti
aninOskar Cvjetičanin1Nejc &#x;arabon,,,
\r\nNejc Šarabon1,2,3,4*
  • 1Faculty of Health Sciences, University of Primorska, Izola, Slovenia
  • 2Human Health, InnoRenew CoE, Izola, Slovenia
  • 3Andrej Marušič Institute, University of Primorska, Koper, Slovenia
  • 4Ludwig Boltzmann Institute for Rehabilitation Research, Vienna, Austria

Introduction: The aim of this study was to assess the validity and reliability of a hydraulic resistance device (HRD) for monitoring sprint split times under different loads within and between sessions.

Methods: Three 20-m sprints with low (15 N), medium-low (40 N), medium-high (50 N), and high (130 N) HRD resistance levels (loads) were performed on two separate occasions 14 days apart. Twenty-four student athletes (24.8 ± 3.8 years) participated in the first session and 13 (24.1 ± 3.2 years) of them in the second session. Resisted sprints split times over a distance of 0–20 m (t0–5, t0–10, t0–20, t5–10, t10–15, t15–20) were measured simultaneously with magnetic incremental encoder embedded in the HRD and a system of single-beam timing gates.

Results: The results showed acceptable to high within session (ICC3,1 = 0.91–0.99; CV = 0.92%–3.38%) and between session (ICC3,1 = 0.82–0.99; CV = 1.62%–4.84%) reliability of HRD for measuring all split times at all loads. The minimal detectable change between sessions ranged from 3.3% at high load to 9.9% at low load. The HRD systematically underestimated timing gates times at all loads (bias = 2.01–11.08%), yet good to excellent consistency was observed between the HRD and timing gates, specifically for t0–10 and t0–20 (ICC3,k lower 95% CI = 0.84–0.99).

Discussion: Due to high reliability and good validity in monitoring resisted sprint times, the HRD holds potential for practical and research applications.

1 Introduction

Sprint and acceleration holds a pivotal role in determining success in a range of sports disciplines (1, 2). In addition to short-distance sprints (3), resisted sprints have garnered substantial attention for its ability to enhance acceleration speed acutely (4), as well as in the long-term (59). In the context of resisted sprinting, a force acts in the opposing horizontal direction to the movement of the sprinter's center of mass, commonly referred to as the resistance force. This necessitates athletes to exert substantial horizontal propulsive forces against the ground (10). Resisted sprint training improves horizontal force production capacity, which is one of the main kinetic indicators of sprint performance (11). Purposely, various devices are employed in practical settings to perform resisted sprints, including aerodynamic (e.g., running parachutes), motorized, pulley, or friction resistance (e.g., sprint sleds) (12, 13).

Non-motorized devices and assemblies designed for resistance sprinting commonly fall short in measuring sprint speed and the associated resistance force, critical components for tailoring training loads individually (12). Despite some successful attempts to estimate resistance force through the friction of sleds in prior studies (14, 15), these calculations are susceptible to a multitude of uncontrollable variables, resulting in variability in recorded resistance force. Furthermore, supplementary equipment, such as timing gates, lasers or radars, must be applied to measure sprint performance accurately in many cases when using resisted sprints assemblies. The variability in resistance force production and challenges in resisted sprint performance measurement on the field could limit the ability to individualize training loads when employing pulley, aerodynamic or friction resistance devices. Because the individualization of resistance has been found to be an important factor for efficient resisted sprint training (16, 17), motorized devices have been recently used, offering the dual benefits of generating and monitoring the resistance force while simultaneously measuring sprint speed (18, 19). The combination of resistance force with spatiotemporal data of sprint forms the foundation for calculating the force-velocity profile (19, 20) and the load-velocity relationship (17, 21, 22). These two outcomes enable the prescription of specific and individualized training loads (23, 24).

Despite the prevalent use of resisted sprints in variety of cyclic movements such as running, skating (25), and swimming (26), the literature on the methodological aspects of non-motorized (i.e., mechanical or pulley) devices for resisted sprints is scarce. Moreover, the comprehensive understanding of resistance force and sprint performance when utilizing hydraulic resistance is lacking. In the present study, we introduce a novel solution, hydraulic-resistance based device (HRD), that produces isotonic resistance force while sprinting. Our unpublished investigations already confirmed consistency of resistance provided by a HRD, therefore the aim of this study was to additionally quantify its ability to assess sprint performance. Our objectives encompass the assessment of within and between session reliability and validity of HRD for measuring sprint split times. We hypothesized HRD would exhibit a high degree of validity and reliability in the measurement of sprint performance. Devices capable of real-time sprint time monitoring that provide objective resistance force can be used to individualize resisted sprint loads on the field, therefore the result of this study would provide valuable information for sports practitioners and athletes striving to enhance speed performance.

2 Materials and methods

2.1 Experimental approach to the problem

A cross-sectional study with two visits was conducted. During each visit, participants completed 20-m sprints with HRD load of 15 N (low), 40 N (medium-low), 50 N (medium-high), and 130 N (high) of resistance force. Sprint split times [at distances from 0 to 5 (t0–5), 0 to 10 (t0–10), 0 to 20 (t0–20), 5 to 10 (t5–10), 10 to 15 (t10–15), and 15 to 20 m (t15–20)] were simultaneously measured with the HRD and single-beam timing gates under all loads.

2.2 Subjects

A sample size power for the intraclass correlation coefficient (ICC) was a priori calculated. For minimum acceptable reliability of 0.5, expected reliability of 0.9 (18), a significance level of 0.05, a statistical power of 0.8, and 2 test-retest trials, a total of 11 participants was required (27). For that purpose, 24 student athletes participated at the first visit and 13 of them were recruited for the second visit. Descriptive statistics of subjects are reported in Table 1. All subjects were amateur athletes from different sport disciplines (i.e., martial arts, football, handball, basketball, track and field, and hockey), involved in training regime consisting of at least 6 sport-specific training sessions per week. Subjects did not report any chronic disease or a recent injury that could compromise the outcomes of the present study. Subjects were informed of the study procedures and signed the informed consent prior the study. The study was conducted in accordance with the Declaration of Helsinki, reviewed, and approved by Medical Ethics Committee under the grant 0120-690/2017/8.

Table 1
www.frontiersin.org

Table 1 Descriptive statistics (mean ± SD) of subjects at the first and at the second session.

2.3 Procedures

Two identical testing procedures were repeated 14 days apart in the gym with a wooden sports floor. A standardized warm-up procedure included 4 min of 50-cm box stepping at a rate of 100 beats per minute, dynamic gymnastics exercises, lower-limb strength exercises (heel raises, hip raises, squats, crunches, and push-ups; 10 repetitions each), running drills (skipping, high knees, hopping, etc.), and three 20-m submaximal sprints. After the warm-up, three maximal sprints with four levels of resistance were performed in a balanced and randomized order. Resistance force during the sprints was provided by the HRD, positioned and firmly fixed 2 m behind the starting line. The HRD was applied to the subject at the waist level with a specially designed harness and belt (Figure 1). Sprint start was performed from standing split-stance position at the participants' own initiative. Backward swaying before the start was not allowed. Subjects were asked to sprint “all-out” at approximately 25 m distance. Between trials 5 to 10 min recovery was allowed. Two fastest sprint trials (t0–20) from the first visit were used for the within session reliability analyses, whereas their average was used for the between session and validity analyses (28).

Figure 1
www.frontiersin.org

Figure 1 The setup for the resisted sprints. The timing gates were positioned on 20-m distance, 5 m apparat. The hydraulic resistance device (HRD) was positioned on rigid box, approximately 2 meters behind start line. Sprint start was performed with the front foot positioned 30 cm prior to first pair of timing gates. The HRD was attached to the subject via harness by using special designed belt.

2.4 Data acquisition and processing

2.4.1 Timing gates

A single-beam photocell timing system (Brower Timing Systems, Draper, UT, USA) was used to acquire t0–5, t0–10, t0–20, t5–10, t10–15, and t15–20 with an accuracy of 0.01 s. Sensors were mounted on tripods above the hip height (∼120 cm above the floor level) to avoid undue interruption by the lower or the upper limbs (29). The pairs of timing gates were positioned at 0 m, 5 m, 10 m, 15 m, and 20 m distances with the first pair positioned 30 cm in front of the subject's front foot (i.e., actual start position) (30).

2.4.2 Hydraulic resistance device

The HRD, presented at Figure 2, is state-of-the-art device developed by the authors. It uses manually adjustable hydraulic system together with the gear system which were used to provide resistance via rope. For the purpose of this study, the resistance force was adjusted to four different loads based on laboratory calibration of the device. The magnetic incremental encoder (model AEAT-601B, Broadcom Inc., San Jose, CA, USA) mounted in the HRD allowed the measurement of subject's position and custom-developed software (ARS Dynamometry, S2P, Ljubljana, Slovenia; created in Labview 8.1., National Instruments, Austin, TX, USA) was used to acquire position signal at a frequency of 1,000 Hz. The raw signal was than processed using customized Python code, including the numpy, scipy, and pandas libraries, and filtered with a 4th order low-pass Butterworth filter (20 Hz cut-off frequency). The trigger criterion for time initiation of start was set at 30 cm from actual increase of position signal, corresponding to the distance between the first pair of timing gates and the starting line. Next, the t0–5, t5–10, t10–15, t15–20, t0–10, and t0–20 were automatically determined from the position-time plots to obtain split times over 5, 10, and 20-m distances, respectively (see Figure 3).

Figure 2
www.frontiersin.org

Figure 2 Hydraulic resistance device used to provide the resistance and assess resisted sprint performance.

Figure 3
www.frontiersin.org

Figure 3 Split times data acquisition from the HRD signals. Graph represent the acquisition of split times for one subject. Split times were calculated from the position-time plots using 30-cm position delay to initialize sprint start (t0), time at 5.3-m distance (t5), time at 10.3-m distance (t10), time at 15.3-m distance (t15), and time at 20.3-m distance (t20) after the start.

2.5 Statistical analyses

Statistical analyses were performed in the SPSS version 26.0 (SPSS Inc, Chicago, IL, USA) and GraphPad Prism version 9.0.2 (GraphPad Software, Inc., San Diego, CA, USA). Mean and standard deviation (SD) were reported as measures of centrality and dispersion of the data. To test the assumption of normality the Shapiro-Wilk test was used for each data set. The two-sided intraclass correlation coefficient for single measures (ICC3,1), interpreted as poor (<0.50), moderate (0.50–0.74), good (0.75–0.90), and excellent (>0.90), was used to assess relative reliability (31). Absolute reliability was assessed using the typical error (TE; as standard deviation of the differences divided by √2) and coefficient of variation (CV; as typical error/mean × 100%). The following criteria were used to determine acceptable (CV ≤ 10%; ICC ≥ 0.80) and high (CV ≤ 5%; ICC ≥ 0.90) reliability (32). The standard error of measurement (SEM; SD × √1-ICC), and the minimal detectable change at the 95% confidence interval (MDC; SEM × √2 × 1.96) were calculated between sessions (33). Differences in HRD split times from first and second visit were assessed using paired sample t-test and Cohen's d effect size (ES). The ES was interpreted as trivial (<0.2), small (0.2–0.6), moderate (0.6–1.2), large (1.2–2.0) and very large (>2.0) (34). The validity of the HRD was based on the consistency and systematic bias between the timing gates and HRD, assessed by CV, two-sided intraclass correlation coefficient for average measures (ICC3,k), paired sample t-test, ES, and Bland-Altman plots with 95% limits of agreement. Statistical significance was set at p < 0.05.

3 Results

The Shapiro-Wilk test confirmed the normal distribution of the split times of the first and second session (p > 0.05). The reliability of the HRD split times within a session at different loads is shown in Table 2. The split times were highly reliable at all loads (ICC3,1 > 0.94; CV < 3.0%).

Table 2
www.frontiersin.org

Table 2 Within session (N = 24) reliability of the hydraulic resistance device (HRD) for measuring split times.

As shown in Table 3, between session reliability of split times was high for most loads (ICC3,1 > 0.83; CV < 4.7), and trivial to small differences in timing were observed between sessions (ES < 0.49). The only exception was t0–5 at low load (ES = −0.64). The MDC of t0–5, t0–10, and t0–20 increased progressively with distance and HRD resistance and ranged from 3.2 to 9.9%.

Table 3
www.frontiersin.org

Table 3 Between session reliability (N = 13) of the hydraulic resistance device (HRD) for measuring split times.

The validity of the HRD for measuring sprint split times at different loads is shown in Table 4. The consistency between timing gates and HRD split times was highest at high load (ICC3,k > 0.92; CV < 2.7%) and lowest at low load (ICC3,k > 0.47; CV < 4.4%). Regardless of the load, the consistency for t0–5 was always the lowest. The HRD systematically overestimated resisted sprint performance. In absolute values, t0–5, t0–10, and t0–20 were underestimated by 0.14–0.21, 0.12–0.19, 0.11–0.18, and 0.12–0.20 s at low, medium-low, medium-high, and high resistances, respectively. Bland-Altman plots 95% limits of agreement range for t0–5, t0–10, and t0–20 at all loads varied from minimum of 0.25 to maximum 0.49 s (Figure 4).

Table 4
www.frontiersin.org

Table 4 Validity of the hydraulic resistance device (HRD) device for measuring split times (N = 24).

Figure 4
www.frontiersin.org

Figure 4 Bland-Altman plots showing absolute differences and 95% limits of agreement in split times (in seconds) between timing gates and the HRD (Δt0−5, Δt0−10, Δt0−20, Δt5−10, Δt10−15, Δt15−20) in sprints with high resistance, medium-low resistance, medium-high resistance, and low resistance. Δt0−5, absolute difference in split time between 0 and 5 m; Δt0−10, absolute difference in split time between 0 and 10 m; Δt0−20, absolute difference in split time between 0 and 20 m; Δt5−10, absolute difference in split time between 5 and 10 m; Δt10−15, absolute difference in split time between 10 and 15 m; Δt15−20, absolute difference in split time between 15 and 20 m.

4 Discussion

The aim of this study was to assess the validity and reliability of the HRD for the evaluation of resisted sprint time. The split times measured with HRD were highly reliable within and between sessions. Despite moderate to excellent consistency between the timing gates and HRD, split times were systematically underestimated. These results suggest that the HRD could be used to record resisted sprint split times under various loads.

The high within session reliability of the HRD is consistent with other studies that have investigated different resistance devices. Godwin et al. (35) measured the split times of resisted sprints with Run Rocket™ using a radar gun and found good to excellent intrasession reliability for the 5 and 10 m times at two resistance levels (ICC = 0.79–0.98; CV = 2.0%–4.6%). In our study, HRD split times provided even higher within session reliability, both in absolute and relative terms (ICC > 0.94; CV < 2.9%). As these results are also comparable to the reliability of a valid motorized resistance device in sprints with 50 N, 80 N and 110 N resistance (18), we can confirm our initial hypothesis of high reliability of the HRD for timing of resisted sprints.

The reliability of magnetic incremental encoders for monitoring performance during sprints with resisted is still relatively unexplored. Highly valid and reliable devices that measured sprint times without resistance at 5, 10, 20 and 30 m distances provided ICC, CV, TE and SWC in the range of 0.83–0.97, 0.8–2.10%, 0.03–0.08 s and 0.01–0.04 s, respectively (36, 37). However, resisted sprints cannot be directly compared with sprints without resistance. Compared to radar used in the study by Godwin et al. (35), HRD showed similar between session reliability for timing resisted sprints (ICC = 0.87–0.97; CV = 2.0%–4.1% for radar vs. ICC3,1 = 0.83–0.99; CV = 1.2%–4.7% for HRD). These results also confirm that HRD is reliable for assessing sprint performance between sessions, therefore the MDC values for the split times are shown in Table 3. For example, at the medium-high load, the t0–10 improvement of 3.5% can be identified as a true change in performance beyond the HRD measurement error. This is comparable to the MDC of the 10 m sprint time using the radar gun (28). Therefore, the HRD can be used to monitor changes in resisted sprint performance.

The validity of the HRD for measuring performance in sprints with resistance is an important feature. The HRD indeed showed excellent reliability, but systematically underestimated the split times compared to the timing gates. Similar observations were previously made by Raković et al. (18), who found that the observed bias was due to the starting position, which can contribute to large absolute differences in split times (38). As the first 5 m of the sprint reflects the start itself, it is not surprising that the largest relative differences for t0–5 across all HRD loads were observed at low load (i.e., from 7% to 11%). In absolute terms, the HRD bias for t0–5, t0–10 and t0–20 remained relatively constant among loading conditions, ranging from 0.11 to 0.21 s. Similar to Raković et al. (18), differences in the initiation of the start between HRD and timing gates are likely responsible for the observed underestimation. As the photocell height of 1.2 m is typically higher than waist level on average, changes in trunk angle from a crouched start to a more upright position later in the sprint may have increased the displacement in HRD and resulted in shorter sprint times. This could systematically underestimate split times when using HRD. Despite the standardization of the sprint start, there was still some biological variability in the start position between subjects causing the variation in the distance between the HRD harness and the first pair of timing gates. Consequently, the Bland-Altman 95% limits of agreement intervals (individual agreement) of t0–5, t0–10, and t0–20 were greater than the MDC of the HRD split times. Given the observed good to excellent consistency between HRD and TG for t0–10 and t0–20 (lower 95% CI for ICC ranged from 0.84 to 0.99), the HRD appears to be valid for assessing resisted sprint split times, particularly at longer distances. Thus, the HRD device can be independently used in practice to measure resisted sprint split times and consequently monitor sprint performance.

Although the results of this study are promising, some of the limitations should be emphasized. First of all, the study was conducted on student athletes, so the result cannot be generalized to the population of elite athletes such as sprinters, footballers or rugby players. In order to obtain population-specific MDC, future studies should investigate the between session reliability of HRD for assessing resisted sprint performance in a group of elite athletes who frequently perform this type of sprint as part of their training regime. Second, we included a wide range of amateur athletes from individual and team sports where acceleration and resisted sprints are part of the sport-specific movement or training. This heterogeneity, in turn, could seemingly increase the consistency between HRD and timing gates. Finally, using single beam timing gates as a criterion may not be the best option when assessing the validity of HRD for evaluating the performance of resisted sprints and future studies should evaluate the validity of HRD together with gold-standard systems.

In conclusion, the results of this study show that the HRD provides good within and between session reliability to monitor split times during resistance sprinting. Regardless of high systematic bias observed between the HRD and single-beam timing gates, very high consistency between methods confirmed good validity of the HRD for measuring sprint times over 10 and 20-m distances. Therefore, we conclude that HRD can be used as a training and testing tool by coaches, athletes and sports scientists for training and research purposes. However, the MDC and underestimation of split times should be taken into account.

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics statement

The study was approved by Slovenia's National Medical Ethics Committee under the grant 0120-690/2017/8. The study was conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study. Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article.

Author contributions

MS: Conceptualization, Data curation, Formal Analysis, Funding acquisition, Investigation, Methodology, Visualization, Writing – original draft, Writing – review & editing. OC: Formal Analysis, Methodology, Software, Writing – review & editing, Writing – original draft. NŠ: Conceptualization, Formal Analysis, Funding acquisition, Investigation, Methodology, Supervision, Validation, Writing – review & editing, Visualization, Writing – original draft.

Funding

The author(s) declare financial support was received for the research, authorship, and/or publication of this article.

This work was supported by the Slovenian Research Agency under grant KINSPO—Kinesiology for the effectiveness and prevention of musculoskeletal injuries in sports (P5-0443).

Acknowledgments

The authors would like to thank to the students of the Faculty of Health Sciences, University of Primorska for the technical assistance and support during the research.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

The reviewer ZK declared a shared affiliation with the authors to the handling editor at the time of review.

The author(s) declared that they were an editorial board member of Frontiers, at the time of submission. This had no impact on the peer review process and the final decision.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Haugen TA, Breitschädel F, Seiler S. Sprint mechanical variables in elite atheletes: are force-velocity profiles sport specific or individual? PLoS One. (2019) 14(7):1–14. doi: 10.1371/journal.pone.0215551

PubMed Abstract | Crossref Full Text | Google Scholar

2. Lorenz DS, Reiman MP, Lehecka BJ, Naylor A. What performance characteristics determine elite versus nonelite athletes in the same sport? Sports Health. (2013) 5(6):542–7. doi: 10.1177/1941738113479763

PubMed Abstract | Crossref Full Text | Google Scholar

3. Haugen T, Seiler S, Sandbakk Ø, Tønnessen E. The training and development of elite sprint performance: an integration of scientific and best practice literature. Sport Med—Open. (2019) 5(1):1–16. doi: 10.1186/s40798-019-0221-0

PubMed Abstract | Crossref Full Text | Google Scholar

4. Zisi M, Stavridis I, Agilara GO, Economou T, Paradisis G. The acute effects of heavy sled towing on acceleration performance and sprint mechanical and kinematic characteristics. Sports. (2022) 10(5):1–10. doi: 10.3390/sports10050077

PubMed Abstract | Crossref Full Text | Google Scholar

5. Makaruk H, Starzak M, Suchecki B, Czaplicki M, Stojiljković N. The effects of assisted and resisted plyometric training programs on vertical jump performance in adults: a systematic review and meta-analysis. J Sport Sci Med. (2020) 19(2):347–5732390728.

PubMed Abstract | Google Scholar

6. Moya-Ramon M, Nakamura FY, Teixeira AS, Granacher U, Santos-Rosa FJ, Sanz-Rivas D, et al. Effects of resisted vs. Conventional sprint training on physical fitness in young elite tennis players. J Hum Kinet. (2020) 73(1):181–92. doi: 10.2478/hukin-2019-0142

PubMed Abstract | Crossref Full Text | Google Scholar

7. Bachero-Mena B, González-Badillo JJ. T he E ffects of T readmill S print T raining. J Strength Cond Res. (2007) 21(1):77–85. doi: 10.1519/00124278-200702000-00015

PubMed Abstract | Crossref Full Text | Google Scholar

8. Makaruk B, Sozański H, Makaruk H, Sacewicz T. The effects of resisted sprint training on speed performance in women. Hum Mov. (2013) 14(2):116–22. doi: 10.2478/humo-2013-0013

Crossref Full Text | Google Scholar

9. Cronin J, Hansen KT. Resisted sprint training for the acceleration phase of sprinting. Strength Cond J. (2006) 28(4):42–51. doi: 10.1519/00126548-200608000-00006

Crossref Full Text | Google Scholar

10. Sugisaki N, Kobayashi K, Yoshimoto T, Mitsukawa N, Tsuchie H, Takai Y, et al. Influence of horizontal resistance loads on spatiotemporal and ground reaction force variables during maximal sprint acceleration. PLoS One. (2023) 18(12 December):2–15. doi: 10.1371/journal.pone.0295758

PubMed Abstract | Crossref Full Text | Google Scholar

11. Morin JB, Edouard P, Samozino P. Technical ability of force application as a determinant factor of sprint performance. Med Sci Sport Exerc. (2011) 43(9):1680–8. doi: 10.1249/MSS.0b013e318216ea37

PubMed Abstract | Crossref Full Text | Google Scholar

12. Cross MR, Tinwala F, Lenetsky S, Brown SR, Brughelli M, Morin JB, et al. Assessing horizontal force production in resisted sprinting: computation and practical interpretation. Int J Sports Physiol Perform. (2019) 14(5):689–93. doi: 10.1123/ijspp.2018-0578

PubMed Abstract | Crossref Full Text | Google Scholar

13. Leyva WD, Wong MA, Brown LE. Resisted and assisted training for sprint speed: a brief review. J Phys Fitness Med Treat Sport. (2017) 1(1):1–6.

Google Scholar

14. Cross MR, Tinwala F, Lenetsky S, Samozino P, Brughelli M, Morin JB. Determining friction and effective loading for sled sprinting. J Sports Sci. (2017) 35(22):2198–203. doi: 10.1080/02640414.2016.1261178

PubMed Abstract | Crossref Full Text | Google Scholar

15. Andre MJ, Fry AC, Bradford LA, Buhr KW. Determination of friction and pulling forces during a weighted sled pull. J Strength Cond Res. (2013) 27(5):1175–8. doi: 10.1519/JSC.0b013e318269aaef

PubMed Abstract | Crossref Full Text | Google Scholar

16. Lahti J, Jimenez-Reyes P, Cross MR, Samozino P, Chassaing P, Simond-Cote B, et al. Individual sprint force-velocity profile adaptations to in-season assisted and resisted velocity-based training in professional rugby. Sport. (2020) 8(5):74. doi: 10.3390/sports8050074

PubMed Abstract | Crossref Full Text | Google Scholar

17. Cross MR, Lahti J, Brown SR, Chedati M, Jimenez-Reyes P, Samozino P, et al. Training at maximal power in resisted sprinting: optimal load determination methodology and pilot results in team sport athletes. PLoS One. (2018) 13(4):1–16. doi: 10.1371/journal.pone.0195477

PubMed Abstract | Crossref Full Text | Google Scholar

18. Rakovic E, Paulsen G, Helland C, Haugen T. Validity and reliability of a motorized sprint resistance device. J Strength Cond Res. (2022) 36(8):2335–8. doi: 10.1519/JSC.0000000000003830

PubMed Abstract | Crossref Full Text | Google Scholar

19. Feser E, Lindley K, Clark K, Bezodis N, Korfist C, Cronin J. Comparison of two measurement devices for obtaining horizontal force-velocity profile variables during sprint running. Int J Sport Sci Coach. (2022) 17(6):1455–61. doi: 10.1177/17479541211067211

Crossref Full Text | Google Scholar

20. Fornasier-Santos C, Arnould A, Jusseaume J, Millot B, Guilhem G, Couturier A, et al. Sprint acceleration mechanical outputs derived from position– or velocity–time data: a multi-system comparison study. Sensors. (2022) 22(22):1–11. doi: 10.3390/s22228610

Crossref Full Text | Google Scholar

21. Cahill MJ, Oliver JL, Cronin JB, Clark KP, Cross MR, Lloyd RS. Sled-pull load–velocity profiling and implications for sprint training prescription in young male athletes. Sports. (2019) 7(5):1–10. doi: 10.3390/sports7050119

PubMed Abstract | Crossref Full Text | Google Scholar

22. van den Tillaar R, Gleadhill S, Jimenez-Reyes P, Nagahara R. A load–velocity relationship in sprint? J Funct Morphol Kinesiol. (2023) 8(135):1–9. doi: 10.3390/jfmk8030135

PubMed Abstract | Crossref Full Text | Google Scholar

23. Morin JB, Samozino P. Interpreting power-force-velocity profiles for individualized and specific training. Int J Sports Physiol Perform. (2016) 11(2):267–72. doi: 10.1123/ijspp.2015-0638

PubMed Abstract | Crossref Full Text | Google Scholar

24. Zabaloy S, Freitas TT, Pareja-Blanco F, Alcaraz PE, Loturco I. Narrative review on the use of sled training to improve sprint performance in team sport athletes. Strength Cond J. (2023) 45(1):13–28. doi: 10.1519/SSC.0000000000000730

Crossref Full Text | Google Scholar

25. Thompson KMA, Safadie A, Ford J, Burr JF. Off-ice resisted sprints best predict all-out skating performance in varsity hockey players. J Strength Cond Res. (2022) 36(9):2597–601. doi: 10.1519/JSC.0000000000003861

PubMed Abstract | Crossref Full Text | Google Scholar

26. Girold S, Calmels P, Maurin D, Milhau N, Chatard JC. Assisted and resisted sprint training in swimming. J Strength Cond Res. (2006) 20(3):547–54. doi: 10.1519/R-16754.1

PubMed Abstract | Crossref Full Text | Google Scholar

27. Arifin WN. A web-based sample size calculator for reliability studies. Educ Med J. (2018) 10(3):67–76. doi: 10.21315/eimj2018.10.3.8

Crossref Full Text | Google Scholar

28. Edwards T, Banyard HG, Piggott B, Gregory Haff G, Joyce C. Reliability and minimal detectable change of sprint times and force-velocity-power characteristics. J Strength Cond Res. (2022) 36(1):268–72. doi: 10.1519/JSC.0000000000004161

PubMed Abstract | Crossref Full Text | Google Scholar

29. Yeadon MR, Kato T, Kerwin DG. Measuring running speed using photocells. J Sports Sci. (1999) 17(3):249–57. doi: 10.1080/026404199366154

PubMed Abstract | Crossref Full Text | Google Scholar

30. Altmann S, Spielmann M, Engel FA, Neumann R, Ringhof S, Oriwol D, et al. Validity of single-beam timing lights at different heights. J Strength Cond Res. (2017) 31(7):1994–9. doi: 10.1519/JSC.0000000000001889

PubMed Abstract | Crossref Full Text | Google Scholar

31. Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. (2016) 15(2):155–63. doi: 10.1016/j.jcm.2016.02.012

PubMed Abstract | Crossref Full Text | Google Scholar

32. Hopkins WG. Measures of reliability in sports medicine and science. Sport Med. (2000) 30(5):375–81. doi: 10.2165/00007256-200030050-00006

Crossref Full Text | Google Scholar

33. Weir JP. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res. (2005) 19(1):231–40. doi: 10.1519/15184.1

PubMed Abstract | Crossref Full Text | Google Scholar

34. Hopkins WG, Marshall SW, Batterham AM, Hanin J. Progressive statistics for studies in sports medicine and exercise science. Med Sci Sports Exerc. (2009) 41(1):3–13. doi: 10.1249/MSS.0b013e31818cb278

PubMed Abstract | Crossref Full Text | Google Scholar

35. Godwin M, Matthews J, Stanhope E, Richards K. Intra and intersession reliability of the run rocketTM in recreationally trained participants. J Hum Sport Exerc. (2020) 16(1):1–18. doi: 10.14198/jhse.2021.161.05

Crossref Full Text | Google Scholar

36. Šarabon N, Kozinc Ž, Ramos AG, Knežević OM, Čoh M, Mirkov DM. Reliability of sprint force-velocity-power profiles obtained with kisprint system. J Sport Sci Med. (2021) 20(2):357–64. doi: 10.52082/jssm.2021.357

PubMed Abstract | Crossref Full Text | Google Scholar

37. Ghigiarelli JJ, Ferrara KJ, Poblete KM, Valle CF, Gonzalez AM, Sell KM. Level of agreement, reliability, and minimal detectable change of the musclelab™ Laser speed device on force–velocity–power sprint profiles in division II collegiate athletes. Sports. (2022) 10(4):1–16. doi: 10.3390/sports10040057

PubMed Abstract | Crossref Full Text | Google Scholar

38. Haugen T, Buchheit M. Sprint running performance monitoring: methodological and practical considerations. Sport Med. (2016) 46(5):641–56. doi: 10.1007/s40279-015-0446-0

PubMed Abstract | Crossref Full Text | Google Scholar

Keywords: resisted sprints, sprint performance, hydraulic resistance, measurement device, validity, reliability

Citation: Sašek M, Cvjetičanin O and Šarabon N (2024) The validity and reliability of a hydraulic resistance device for assessing resisted sprint time. Front. Sports Act. Living 6: 1386882. doi: 10.3389/fspor.2024.1386882

Received: 16 February 2024; Accepted: 15 July 2024;
Published: 25 July 2024.

Edited by:

Filipe Manuel Clemente, Polytechnic Institute of Viana do Castelo, Portugal

Reviewed by:

Rui Miguel Silva, Instituto Politécnico de Viana do Castelo, Portugal
Ryu Nagahara, National Institute of Fitness and Sports in Kanoya, Japan

© 2024 Sašek, Cvjetičanin and Šarabon. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Nejc Šarabon, bmVqYy5zYXJhYm9uQGZ2ei51cHIuc2k=

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.