Positive airway pressure delivery: overcoming old hurdles, exploring new frontiers

\r\nLudovico Messineo
Ludovico Messineo1*David P. WhiteDavid P. White1William H. NoahWilliam H. Noah2
  • 1Division of Sleep and Circadian Medicine, Harvard Medical School, Brigham and Women's Hospital, Boston, MA, United States
  • 2Sleep Centers of Middle Tennessee, Murfreesboro, TN, United States

Despite being the gold-standard treatment for obstructive sleep apnea (OSA), continuous positive airway pressure (CPAP) faces important challenges, particularly with patient adherence. Many individuals find CPAP difficult to tolerate due to noise, social inconveniences, characteristics inherently linked to their sleep disorder and side effects, including mask discomfort, air leaks, nasal congestion, and the unnatural sensation of exhaling against positive pressure. All this often leads to reduced usage, limiting CPAP's potential to deliver long-term health benefits. This review revisits the dynamics of pharyngeal collapse during sleep on PAP, offering a new interpretation that challenges the long-standing view that higher inspiratory pressure is required to maintain pharyngeal patency. Emerging evidence, combined with the knowledge from older studies, suggests that airway collapse often occurs near end-expiration, which may be the only time that substantial positive airway pressure is required. Efforts to improve CPAP compliance have reduced expiratory pressure, leading to the introduction of bilevel PAP (BPAP) and expiratory pressure relief algorithms, which may cause airway destabilization, without yielding the improvements in adherence that were initially anticipated. Thus, despite over three decades of innovation, which have also seen heated humidifiers and tubes, customized 3D-printed masks and auto-titrating PAP come to market, there has been limited success in systematically increasing long-term CPAP adherence rates. In response, we discuss novel approaches such as V.-Com® and KairosPAP™ (KPAP™), which reduce inspiratory pressure and, in the case of KPAP™, also much of expiratory pressure, returning to full pressure only at the end of expiration. Recent studies suggest these technologies improve comfort and reduce unintentional leaks and may lead to better adherence without sacrificing treatment effectiveness. This aligns with the hypothesis that stabilizing the airway during end-expiration may be key to enhancing CPAP comfort and adherence. In conclusion, while technological advancements have improved the CPAP experience, further progress will likely come from solutions that better address patient comfort with the applied pressure. KPAP™ is one such innovation with the potential to enhance adherence, but additional research is needed to fully understand its long-term impact and effectiveness in PAP therapy for OSA.

1 Introduction

Obstructive sleep apnea is characterized by chronic, self-propagating narrowing—or obstruction—of the upper airway. To date, more than 40 years after its discovery (Sullivan et al., 1981), continuous positive airway pressure (CPAP) remains the gold-standard treatment for OSA due to its high efficacy in resolving respiratory events. For example, CPAP, differently than other OSA treatments such as mandibular advancement devices or hypoglossal nerve stimulation, addresses OSA through mechanically splinting the upper airway open, regardless of the underlying cause of obstruction, e.g., impaired anatomy, low lung volume or increased arousability (Messineo et al., 2024a,c; Messineo and Eckert, 2022). In addition, substantial evidence supports CPAP's effectiveness in alleviating OSA-related symptoms (McDaid et al., 2009; Kuhn et al., 2017) and reducing blood pressure (Gottlieb et al., 2014). However, large, multi-centric randomized controlled trials have failed to show a clear protective effect of CPAP on cardiovascular outcome in OSA patients (Sanchez-de-la-Torre et al., 2020; Labarca et al., 2020; McEvoy et al., 2016; Peker et al., 2016). This may be dependent on an actual lack of a protective effect of CPAP on the cardiovascular system, but could also stem from several other factors: (1) the apnea hypopnea index (AHI) may be an inadequate biomarker for patient selection compared to more sensitive measures such as hypoxic burden (Messineo et al., 2024a), (2) participants in these RCTs may not accurately represent real-world OSA populations (Gerves-Pinquie et al., 2022), (3) CPAP pressures may lead to the release of pro-inflammatory mediators secondary to stretch of endothelial or epithelial cells in the lung, which could increase the risk of adverse cardiovascular events (Peker et al., 2024; Gottlieb et al., 2022; Shah et al., 2023), and (4) poor adherence among trial participants may skew results (Sanchez-de-la-Torre et al., 2023). Indeed, adherence is arguably the greatest limitation of CPAP therapy. Based on the above observations, one could speculate that, if all patients adhered fully to CPAP, their cardiovascular outcomes would improve significantly. However, despite over three decades of technological advancements, CPAP adherence rates remain disappointingly low (Rotenberg et al., 2016).

In this narrative review, we discuss the current challenges that may undermine the effectiveness of CPAP therapy, and provide an overview of how the scientific community has sought to address these issues, including recent advancements in PAP delivery algorithms. To prepare this review, we conducted a comprehensive search of major scientific databases (PubMed, Google Scholar, ClinicalTrials.org) from their inception to the present, aiming to outline the current limitations of CPAP therapy and highlight potential future improvements.

2 Main limitations of CPAP

CPAP usage is hindered by social factors, device-related issues, side effects and patient-related factors (Figure 1). Socially, CPAP is often perceived as a burden by patients. Although the CPAP machine has been reduced by almost a third of its original size, it is still not easy to carry or transport conveniently, especially for frequent travel or daily mobility, and it may be cumbersome for patients to use outside of their home, limiting its practicality and ease of use. Another social factor affecting CPAP usage is inadequate support from bed partners, either due to non-dyadic sleep patterns (Lewis et al., 2004) or because the bed partner does not adequately encourage CPAP use or is disturbed by the noise from the device (Gentina et al., 2019).

Figure 1
www.frontiersin.org

Figure 1. CPAP adherence is hindered by social factors, device- and patient-related issues and side effects (top left). While technological advancements like heated humidifiers, heated tubes, and a wide variety of mask types (top right) may have enhanced the CPAP experience, data on adherence remain inconsistent, with adherence rates still low. Despite the early assumption that bilevel positive airway pressure (BPAP), with the introduction of pressure support [i.e., reducing expiratory PAP (EPAP) and potentially increasing inspiratory PAP (IPAP) for compensation], would improve adherence—based on the belief that higher pressures are required during inspiration—studies have shown this not to be the case. The ineffectiveness of expiratory pressure relief algorithms (EPRAs, such as C-Flex) and mask compensation algorithms, which mimic pressure support, further confirm this. Instead of improving adherence, these technologies often result in side effects (bottom left) and are less effective in maintaining upper airway patency, largely due to reductions in end-expiratory lung volume (EELV) and pharyngeal lumen cross-sectional area (bottom right).

A number of device-related factors can negatively impact the CPAP experience, such as mask discomfort, leaks, and noise from the device, although CPAP machines are much quieter now than in the past (Shirlaw et al., 2017; Pepin et al., 1995). In addition, CPAP can be responsible for circuit CO2 rebreathing (Messineo et al., 2024b). This may occur at low PAP levels or high respiratory volumes, when the patient exceeds the exhaust valve's flow capacity, and cause exhaled CO2 to flow back in the CPAP tubing to be inhaled during the next breath. The ensuing mild hypercapnia may cause anxiety, which, in turn, could lead to poor treatment adherence (Goossens et al., 2014; Woods et al., 1988).

Side effects impact up to 65% of users and include nasal congestion and epistaxis, xerostomia, facial lesions (i.e., skin marks or rashes), conjunctivitis, claustrophobia and aerophagy (Pepin et al., 1995; Brostrom et al., 2010; Strumpf et al., 1989). For many patients, exhaling against positive pressure can feel unnatural and may also contribute to insomnia (Ghadiri and Grunstein, 2020). These side effects are not always limited to the CPAP initiation. Although some tend to resolve with chronic usage, others can still emerge within the first year (Ulander et al., 2014). In addition, both social factors and side effects can exacerbate treatment-related anxiety over time and drive reduced adherence rates.

The propensity for low CPAP adherence can also be a consequence of factors inherently related to the patient, particularly abnormal OSA endotypes. As mentioned above, OSA can be the product of altered anatomy and a number of impaired physiological traits, such as high loop gain, low arousal threshold and poor pharyngeal muscle responsiveness (Messineo et al., 2024a,c). These traits can also contribute to reduced treatment adherence. For instance, patients with low arousal threshold, who tend to awaken easily in response to mild respiratory stimuli, may be more prone to frequent awakenings due to CPAP discomfort (e.g., noise, mask, etc.), leading to CPAP intolerance (Zinchuk et al., 2020). Additionally, patients with either very low or very high pharyngeal muscle responsiveness have shown lower adherence rates (Zinchuk et al., 2020). High loop gain has also been associated with improved adherence (Zinchuk et al., 2021), but a high loop gain is also linked the onset of central sleep apnea (CSA), which can negatively affect CPAP adherence (Cheng et al., 2024). A prospective study to assess the impact of physiological traits on PAP adherence is ongoing (Anwar et al., 2024).

At the end of the day, adherence is the ultimate problem. Patients experiencing CPAP-related social problems, device issues, or side effects may reduce their CPAP usage time or discontinue treatment altogether. Ultimately, how much can time on therapy be reduced and still be considered acceptable or effective? A threshold that has become clinically accepted worldwide is 4 h per night for at least 5 days a week (Kribbs et al., 1993). Also, many private insurers in the U.S. require this level of adherence for 30 days within the first 90 days of treatment to maintain CPAP coverage (Fujita et al., 2024). However, this threshold is arbitrary, and it is possible that, for example, only a full night of therapy 7 nights a week will improve OSA-related long-term outcomes. Nonetheless, this level of adherence seems out of reach for many patients. Indeed, early studies found adherence rates (per 4-h/night threshold) settling around 50% (Sawyer et al., 2011; Weaver and Grunstein, 2008). Two recent, real-world studies found adherence to be higher in the first 90 days of therapy (~75%) (Cistulli et al., 2019), as well as after 1 year (Morrone et al., 2020), with a mean CPAP usage time of ~5 h per night. However, this may still be inadequate, although comparable to adherence rates with pharmacotherapy for other chronic disease such as hypertension (Alsabbagh et al., 2014), diabetes (Cramer, 2004) and epilepsy (Getnet et al., 2016). In addition, adherence rates (Hwang et al., 2018) and usage time (Patel et al., 2022) tend to dramatically drop as early as 1 month after PAP prescription, and continue to decrease after 1 year of use. A recent parallel-group trial, assessed the effect of 6 months of a peer driven intervention (i.e., fully adherent CPAP patients acting as mentors for CPAP-naïve patients) on adherence in 263 participants. In the active control group, average adherence was < 4 h/night, with only 50% of patients reaching the recommendation of at least 4 h/night. Although the experimental intervention significantly increased CPAP adherence and was looked at as a therapeutic success, mean adherence went up by less than an hour, with only 62% of patients in the experimental treatment arm meeting the goal of 4 h of CPAP per night (Parthasarathy et al., 2024). Hence, these figures highlight that there is still abundant opportunity for further improvement in CPAP usage.

3 Technological improvements to address CPAP limitations

Over the past three decades, various efforts have been made to address the above CPAP limitations. Numerous examples of these technological innovations exist (Figure 1).

3.1 Humidification

Humidifiers were introduced in the ‘90s as a tool to reduce nasal symptoms (Parra et al., 1991). Without humidification, airflow through the nose dries the nasal mucosa and the faster the velocity of airflow, the more pronounced the drying will be (a phenomenon known as “jetting”). This leads to the release of vasoactive and proinflammatory mediators that increase superficial mucosal blood flow and cause vessel engorgement, particularly in the presence of mouth leaks, ultimately raising nasal resistance (Hayes et al., 1995). Hygroscopic humidifiers—or heated moisture exchangers—were shown to provide control of nasal symptoms and better adherence in early reports (Parra et al., 1991; Massie et al., 1999), although subsequent studies showed more mixed results. While some indicated improvement of nasal symptoms and inflammation following the use of heated humidifiers (Koutsourelakis et al., 2011; Rakotonanahary et al., 2001), others pointed at only modest-to-negligible improvement in CPAP adherence in the face of no benefits in daytime sleepiness or overall treatment satisfaction (Neill et al., 2003), especially in unselected OSA patients (Duong et al., 2005; Patil et al., 2019). Today, humidifiers are recommended only for patients experiencing nasal symptoms. Most CPAP devices now allow for customizable humidification levels based on individual needs.

3.2 Controlled heated breathing tube humidifiers

Introduced in the early 2000s, heated tubes represented another technological advancement aimed at preventing condensation buildup inside the tubing, especially at lower temperatures (Nilius et al., 2008), a common issue with earlier CPAP machines, that could disrupt airflow and comfort during use. Although heated tubes improved nasal symptoms for patients who prefer cooler bedroom environments (Nilius et al., 2008), they did not affect quality of life of OSA of patients or CPAP adherence in the short (Ruhle et al., 2011) or long term (Galetke et al., 2016) vs. conventional heated humidification.

3.3 Mask types

A wide variety of masks now provides patients with multiple options to achieve the best fit, enhancing comfort and minimizing leakage. In addition to selecting from full face masks, sub-nasal masks, nasal masks and nasal pillows, patients can also compare several mask brands. In addition, customizable 3D-printed masks have also been introduced to maximize fit (Hussin et al., 2021; Hsu et al., 2015). A well-fitting mask can help reduce pressure-related (e.g., skin lesions) and device-related (e.g., noise) side effects, depending on their geometry and intentional leak (Messineo et al., 2024b). However, the abundance of mask options may contribute to “choice fatigue” (Shah and Wolford, 2007), potentially leading to an incorrect initial selection and subsequent mask switching after therapy commencement, which can negatively impact CPAP adherence (Bachour et al., 2016). Although some differences in treatment adherence between nasal mask brands have been reported (Neuzeret and Morin, 2017), inconsistent findings indicate that, overall, there may not be a substantial difference in CPAP adherence between mask types (Patil et al., 2019; Benjafield et al., 2021; Rowland et al., 2018; Borel et al., 2013). Regardless, mask resupply has to be kept regularly executed to avoid sharp drops in adherence rates (Benjafield et al., 2021).

4 Pressure delivery algorithms to improve comfort

Despite the above improvements, which brought considerable reduction of nasal and facial symptoms, device-related issues (such as noise), and social factors (such as portability), adherence to CPAP therapy has not significantly improved, especially in the long run (Rotenberg et al., 2016). This suggests that the primary barrier to CPAP adherence may be intolerance to the pressure, particularly, it was believed, the discomfort experienced when exhaling against a positive pressure. Pressure intolerance may vary based on individual sensitivity, although some have hypothesized that persistent airway inflammation due to CPAP may be a contributor (Devouassoux et al., 2007).

Based on this notion, technology has evolved over the years to yield more tolerable methods of delivering pressure for CPAP therapy. However, almost all these advancements have not reached the goal of improving adherence (Figure 1), potentially due to negligible improvement in patient comfort related to PAP delivery.

4.1 Bilevel PAP (BPAP)

The introduction of BPAP in the early ‘90s was the first attempt to tackle pressure intolerance (Sanders and Kern, 1990). The prevailing view was that exhaling against a lower expiratory PAP (EPAP) could enhance comfort, while providing a higher inspiratory PAP (IPAP) could preserve upper airway patency. Specifically, it was thought that the normal negative inspiratory pressure which would tend to collapse the upper airway was not completely offset by pharyngeal muscle activation. Thus, airway narrowing forces were stronger during inspiration than exhalation (Remmers et al., 1978). To counteract these forces, higher pressures during inspiration were thought to be necessary, while reducing expiratory pressures was a logical predicate to reduce discomfort from exhaling against positive pressure. This approach was also believed to reduce mean pressure exposure while maintaining airway patency (Sanders and Kern, 1990). The notion that BPAP reduces the work of breathing by providing pressure support (IPAP > EPAP), where a higher IPAP supports inspiration and a lower EPAP reduces the effort needed for exhalation (Vitacca et al., 2001), was a further foundation for its use in OSA. A role for EPAP was still recognized, as it needed to be set above a critical level to prevent apneas and ensure sufficient airflow to trigger IPAP (Sanders and Kern, 1990; Resta et al., 1999). BPAP pressure curves are illustrated in Figure 2.

Figure 2
www.frontiersin.org

Figure 2. Different positive airway pressure (PAP) delivery algorithms. Bilevel PAP (BPAP) provides pressure support by delivering a higher inspiratory PAP (IPAP) than expiratory PAP (EPAP). Expiratory pressure relief (EPR) algorithms and C-Flex are features of continuous PAP devices designed to lower EPAP below therapeutic levels, thereby simulating pressure support (IPAP > EPAP). Kairos PAP™ (KPAP™) reduces pressure in two initial drops (red marks) starting in inspiration and returning to therapeutic levels only near the end of expiration (“the right time”). Inspiration (ins) is conventionally indicated by the flow curve above the dashed horizontal line, while expiration (exp) is the flow curve below the same line. Dashed vertical lines separate inspiration from expiration.

However, multiple studies have shown that BPAP is not superior to CPAP in terms of adherence (Gay et al., 2003; Reeves-Hoche et al., 1995; Smith and Lasserson, 2009). It is possible that BPAP (or auto-adjusting BPAP) could be beneficial as a rescue therapy for selected OSA populations, such as patients specifically experiencing pressure intolerance (Benjafield et al., 2019; Carlucci et al., 2015; Palot et al., 2023), or obese individuals (Ishak et al., 2020); however, results on this topic have been inconsistent (Gulati et al., 2015). There is also evidence suggesting BPAP might actually destabilize the upper airway (Levy et al., 1994). Indeed, simply reducing EPAP leads to increased flow limitation (Figure 3) (Series and Marc, 1998), potentially necessitating an increase in IPAP beyond CPAP levels to offset this effect. This can lead to higher peak pressures and potentially increases the risk for central apnea events (see below).

Figure 3
www.frontiersin.org

Figure 3. (A–D) Signal variations at increasing expiratory positive airway pressures (EPAP) with stable inspiratory PAP (IPAP). Note that as EPAP is reduced (reading right to left), peak flow steadily drops, almost certainly secondary to reduced airway patency. In addition, driving pressure [difference between mask pressure (Pmask) and esophageal pressure, representing efforts] and GG (genioglossus) electromyography (EMG) activity increase. Horizontal lines highlight zero flow (dashed) and swings in flow and driving pressure at minimal EPAP (dotted), to underscore increases in flow and decreases in effort with raising EPAP levels. Modified from Series and Marc (1998) (reproduced with permission).

4.2 Auto-titrating PAP (APAP)

APAP was initially introduced to eliminate in-laboratory titration, allowing the device to adjust pressure within a set range (minimum and maximum) over one night to a week, determining the pressure needed to treat respiratory events for 90% or 95% of the night (P90 and P95, respectively) (Rosen et al., 2012). However, APAP is now frequently used for routine treatment as it is commonly believed to improve adherence due to the reduction in overall pressure exposure. However, evidence supporting better adherence with APAP remains weak (Patil et al., 2019). In fact, fixed CPAP appears more effective on glycemic control (Shaw et al., 2016) and in lowering 24-h blood pressure (Pepin et al., 2016), and higher fixed pressures has been linked, in some studies, to better adherence (Van Ryswyk et al., 2019). Notably, both APAP and certainly BPAP have higher costs than CPAP.

4.3 Expiratory pressure relief algorithms (EPRAs)

Although most uncomplicated OSA patients do not routinely use BPAP at home, EPRA, such as C-Flex (proprietary to Philips Respironics) and EPR by ResMed, have become widely used in the past 20 years (Juhasz et al., 2001). EPRAs allow preferential reductions in EPAP (generally 1 to 3 cmH2O), thus providing low-level pressure support (i.e., IPAP > EPAP), in a similar fashion—though reduced in magnitude—to BPAP. The difference between various EPRAs, other than being proprietary to different manufacturers, lies within the shape of the curve of the reduced expiratory pressure (Figure 2). Each algorithm adjusts the pressure differently, affecting how smoothly or gradually the pressure is reduced during exhalation and returned prior to the next inspiration. Again, this technology was introduced based on the belief that IPAP was necessary to preserve upper airway patency and higher EPAP was simply uncomfortable. However, despite some pilot data showing a potential benefit of C-Flex with APAP vs. other EPRAs or vs. standard APAP (Chihara et al., 2013), overwhelming evidence indicates that neither C-Flex (Patil et al., 2019; Smith and Lasserson, 2009; Dolan et al., 2009; Bakker et al., 2010; Zhu et al., 2016), nor EPRAs (Patil et al., 2019; Smith and Lasserson, 2009), lead to improvements in adherence vs. standard CPAP, with the possible exception of C-Flex as a rescue therapy in patients with low CPAP tolerance (although long-term data supporting this finding are lacking) (Pepin et al., 2009a).

4.4 Mask compensation algorithms

Finally, CPAP manufacturers have introduced mask compensation algorithms, designed to offset the increased resistance associated with CPAP masks, particularly nasal pillows, which have the highest within-mask resistance. Since increased resistances are associated with drops in pressure, the algorithm compensates for such nasal-pillow-related drops in inspiratory pressure, providing a higher IPAP, and thus creating pressure support. However, there are no data to our knowledge supporting increased adherence with the use of this feature.

5 Potential reasons for why lower expiratory pressure does not increase adherence

There is ample evidence that pharyngeal collapse is not limited to inspiration—it also occurs during end-expiration (Sanders and Moore, 1983; Tamisier et al., 2004). The Starling resistor model, which represents the upper airway as a collapsible tube with intraluminal and surrounding pressures (Schwartz et al., 1988; Gold and Schwartz, 1996), supports the idea that complete airway obstruction primarily starts during expiration, when the airway muscles are most quiescent. In this model, during inspiration, when the surrounding pressure equals the downstream pressure (e.g., in the trachea), a choke point (i.e., flow limitation) ensues (Dawson and Elliott, 1980) and no further increase in airflow is possible, independent of further effort or further decrease in the downstream pressure. Therefore, according to this model, it is impossible to suck the airway fully closed. This means inspiratory negative pressure does not make the upper airway more susceptible to complete collapse (i.e., apneas), which is different from end-expiration. A study indicating minimal airway narrowing during inspiration and a reduction in pharyngeal size at end-expiration (when lung volume is at its nadir) further substantiated this model (Schwab et al., 1993). However, research has also shown that the upper airway exhibits a more complex, purely elastic behavior, where dynamic changes in the downstream pressure quickly affect the size of the airway (e.g., negative effort dependence) and there is potential for complete pharyngeal collapse also starting in inspiration (Owens et al., 2012). Therefore, this would not always reflect the dynamics of a Starling resistor and suggests that the upper airway could have a more complex behavior (Owens et al., 2012; Genta et al., 2016). The main neglected aspect in the purely elastic model is viscosity, which dictates that the airway will not return to its resting state immediately after a change in intraluminal pressure. Strong evidence to support this viscous nature is the ability of nasal EPAP (nEPAP) devices to treat hypopneas and snoring (Kryger et al., 2011), which can occur in inspiration. At the end of expiration with nEPAP, flow and pressure are both 0. Thus, any improvement on the subsequent inspiration (reduction or elimination of hypopneas and snoring) could be due to the viscous properties of the airway, which does not immediately collapse to its resting state.

Nonetheless, if airway collapse was typically assumed to occur during inspiration, lowering EPAP through BPAP or some EPRAs (i.e., especially those with a reduction in EPAP for the entire duration of expiration) would be at least as effective as CPAP in dilating the upper airway. However, this turned out not to be true (Figure 1). The upper airway is a very compliant structure whose area can increase substantially on CPAP (Schwab et al., 1996). Progressive decrements in EPAP are associated with dramatic declines in pharyngeal lumen cross-sectional area (Gugger and Vock, 1992) and reductions in airflow (Figure 3) (Series and Marc, 1998). Decreasing EPAP from therapeutic levels also causes a decrease in lung volume (Bishop et al., 1978). Drops in lung volumes can, in turn, negatively affect pharyngeal stiffness and cross-sectional area (Burger et al., 1992; Hoffstein et al., 1984), due to a loss of a tractional effect on the trachea and the upper airway (Owens et al., 2010; Kairaitis et al., 2007; Rowley et al., 1996). Tractional forces on the trachea refers to the mechanical pull on the upper airway that reduces compliance of the pharynx making it less collapsible. As lung volume decreases, this traction is diminished, reducing the pharyngeal cross-sectional area and making airway collapse more likely (Van de Graaff, 1988). Reductions in lung volume lead to sizable increases in CPAP requirements (Heinzer et al., 2005) and to worsening of OSA severity (Heinzer et al., 2006). Notably, a study showed that increasing EPAP does not necessarily translate into lung volume increments during sleep (Heinzer et al., 2008), possibly due to a servo mechanism that prevents hyperinflation. This suggests that some IPAP might be necessary to maintain adequate lung volumes in support of upper airway patency. However, significant lung volume reductions are observed at sleep onset (Hudgel and Devadatta, 1984; Stadler et al., 2010), or after shifting from lateral to supine position (Messineo et al., 2023). In otherwise healthy OSA patients, EPAP—and not IPAP—compensates for this drop in lung volume, addressing the ensuing worsening respiratory events.

On the other hand, higher IPAP does not dilate the upper airway for two key reasons. First, the set IPAP level is not fully delivered to the pharyngeal airway due to the resistance in the oronasal pathway, which dissipates the pressure (Figure 4). Second, since the pharyngeal cross-sectional area is smaller during inspiration (Schwab et al., 1993), there is less surface area for the positive pressure to act on. The force required to dilate the airway is the product of pressure and surface area, meaning that greater IPAP is needed to achieve the same upper airway dilation seen with EPAP (Figure 1). Therefore, reducing EPAP could lead to substantial increases in IPAP to maintain equivalent upper airway patency, or to increases in transthoracic pressure to preserve the same tidal volume (which could translate into an increased work of breathing). This should have been clear when Sanders et al. introduced bilevel pressure and noted that higher IPAP could not treat apneas, while lower EPAP could (Sanders and Kern, 1990).

Figure 4
www.frontiersin.org

Figure 4. Respiratory dynamics at different positive airway pressure (PAP) settings. During inspiration (left), the pressure at the mask dissipates as it travels to the pharynx due to high upper airway resistance and turbulent flow. For example, an inspiratory PAP (IPAP) of 10 cmH2O may reduce to 7–8 cmH2O, as some pressure is lost by overcoming the resistance. This pressure might be insufficient to keep the airway open. Alveolar pressure is lower as flow has to follow a pressure gradient. During expiration (right), pressure in the alveoli must be higher than atmospheric pressure. Thus, with an expiratory PAP (EPAP) of 10 cmH2O, there must be sufficient pressure at the alveoli, e.g., 15 cmH2O, to create a pressure gradient. This pressure dissipates again in the pharynx due to resistance, but remains above the atmospheric pressure (e.g., 12–13 cmH2O) and contributes to stabilizing the upper airway.

Finally, it is possible that adding pressure support (IPAP > EPAP) increases the rate of unwanted central events (Figure 1), which can subsequently negatively affect adherence rates (Mulgrew et al., 2010). For example, augmented tidal volume from high IPAPs (Barach and Eckman, 1947; Campana et al., 2013) can trigger CSA (Zeineddine and Badr, 2021; Meza et al., 1998; Johnson and Johnson, 2005) or treatment emergent CSA (TECSA) (Malhotra et al., 2008), especially in individuals with high respiratory instability, i.e., high loop gain (Zeineddine and Badr, 2021). Even low levels of pressure support, such as with C-Flex, can elevate the likelihood of CSA (Loh et al., 2014) or TECSA (Noah et al., 2024). Several other adverse events linked to pressure support may contribute to reduced adherence. Decreasing EPAP heightens the chances of circuit-dependent CO2 rebreathing, especially with certain masks and at low PAPs. This occurs when the patient's exhaled airflow exceeds the exhaust flow (which is capped by mask specifications) and flows back into the CPAP tube. Thus, CO2 is rebreathed on the next inspiration (Messineo et al., 2024b). As aforementioned, rebreathing is a subtle cause of CPAP intolerance (Ferguson and Gilmartin, 1995).

High IPAP can also exacerbate unintentional leak, as leak is proportionate to the peak circuit pressure (Lebret et al., 2018). A pressure that is too high—such as with high IPAPs or with APAP devices which keep increasing EPAP to compensate for the leak—can displace the mask or be responsible for uncoupling of the tongue and soft palate, leading to mouth leak (Genta et al., 2020). Such unintentional leak has been described as a cause of decreased CPAP adherence (Rapoport, 1996; Baltzan et al., 2009). Indeed, leak can be disturbing to both the patient and the patient's bed-partner, and compromise their sleep architecture (Meyer et al., 1997).

Finally, high IPAP might induce more aerophagia by increasing the pressure gradient driving airflow into the esophagus. Aerophagia is a relatively common side effect of non-invasive ventilation (Gong and Sankari, 2024). Intuitively, increasing peak pressure as occurs with increased IPAP should raise the likelihood of aerophagia. This is supported by the observation that aerophagia is more prevalent with oronasal vs. nasal masks (Shirlaw et al., 2017), likely because oronasal masks have less resistance than nasal masks, leading to less pressure dissipation before the pharynx (i.e., IPAP at the pharynx is higher on oronasal vs. nasal masks).

It should also be noted that patients with uncomplicated OSA typically do not need pressure support to breathe, as their respiratory drive is intact and their lung physiology is quite normal. Since pressure support does not increase treatment adherence, the rationale behind administering IPAP > EPAP in otherwise healthy OSA patients seems misguided. Indeed, inspiring at higher pressures may be perceived as less comfortable, as the patient may feel less in control of their own inspiratory flow characteristics. They are thus “forced” into breaths by sudden pressure increases (Figure 5). Higher IPAP pressures also change the rate of chest wall expansion, diaphragm tension, and the flow rate through the pharynx when compared with natural breathing. Currently, the lowest IPAP that can be administered equals EPAP (i.e., CPAP). However, further lowering IPAP could more closely mimic natural breathing, namely breathing at lower pressures and at a pace that suits the individual patient. In addition, if pharyngeal narrowing primarily occurs at end-expiration, a lower IPAP should not compromise upper airway patency (Figure 5).

Figure 5
www.frontiersin.org

Figure 5. Potential mechanisms for improved comfort when inspiratory positive airway pressure (IPAP) is set lower than expiratory PAP (EPAP). This figure illustrates a hypothetical comparison between a device delivering IPAP equal to or higher than EPAP, as seen in continuous or bilevel PAP (left inset), and a device delivering IPAP lower than EPAP, such as V.-Com® or KairosPAP™ (right inset). See text for full details.

6 V.-Com® as the first attempt to lower IPAP

V.-Com® is a flow-dependent resistor, introduced in 2022 and FDA-approved as a class 1 device (similar to hoses, chinstraps, etc.), designed to enhance CPAP comfort by adding a non-compensated resistance to the CPAP circuit. Positioned in the tubing before the mask, V.-Com® introduces a small amount of resistance that varies with flow, approximately 1.7 cmH2O at 50 L/min and increasing in a parabolic fashion—just over 0 cmH2O at 10 L/min and around 4.5 cmH2O at 70 L/min.

As shown in Figure 6, when a patient is connected to a CPAP, the flow through V.-Com® reflects the flow in the CPAP circuit. During inspiration, this is approximately 40–60 L/min, and accounts for both the machine's adjustments to maintain the set pressure and the patient's own inspiratory flow (5–8 L/min), plus the exhaust flow and potential leak flow. Importantly, the machine does not “breathe” for the patient, but supports the positive pressure required to keep the airway open and compensates for any leak in the system. Thus, the V.-Com®-related reduction in IPAP is approximately 1.5–2 cmH2O during inspiration. Conversely, during expiration, the machine adjusts flow minimally to maintain positive pressure, while most of the patient's exhaled air exits through the exhaust valve (unless in the presence of rebreathing), or through unintentional leak. Thus, during expiration, the flow going through V.-Com® is minimal and there is negligible variation in EPAP.

Figure 6
www.frontiersin.org

Figure 6. During inspiration (left), the flow through V.-Com® (inset) is high as it mainly comes from the flow that the patient generates to breathe air in (green arrows). As a result, there is a corresponding drop in IPAP when pressure goes through V.-Com®. During expiration (right), the exhaled air (red arrows), in absence of rebreathing, exits through the exhaust valve and potentially the mouth (due to unintentional leak). Thus, the flow passing through V.-Com® is minimal on expiration and there is no significant drop in EPAP.

In a study (Farney et al., 2024), 102 patients using an APAP device at home were studied for 4 days with V.-Com® and 4 days without it, according to a crossover design. Patients were selected to be highly adherent to PAP therapy, with at least 6 documented hours of use per night over the previous 3 months. The patients were aware of the intervention. The first 62 patients were recruited independent of the CPAP device manufacturer they were using at home, while the last 40 were all using ResMed devices. Outcome data were downloaded from device built-in algorithms. In both patient groups, the introduction of V.-Com® did not have a clinically meaningful effect on P90/P95, while it significantly decreased residual AHI vs. no V.-Com® (1.79 ± 1.74 vs. 2.15 ± 2.35 events/hour, respectively, P = 0.017). This suggests that the reduced IPAP with V.-Com® does not interfere with pressure delivery or the auto-titration algorithms, nor does it compromise pharyngeal patency. Rather, it highlights that expiration—as opposed to inspiration—is likely the most vulnerable phase for airway collapse, and maintaining therapeutic EPAP during at least a portion of the expiratory cycle is crucial in preventing respiratory events. Interestingly, in the first group, the V.-Com® placement increased usage time by approximately 4% (from 7.3 ± 1.3 to 7.6 ± 1.4 h a night, P = 0.026), potentially secondary to reduced leakage (unintentional leak was significantly reduced by about a third in both groups—from 12.3 ± 9.3 to 8.1 ± 7.1 L/min, P < 0.001, in the first group, and from 8.8 ± 10.9 to 5.9 ± 6.4, P = 0.007, in the second group) and increased comfort. Indeed, 74% of all participants preferred to continue at-home therapy with V.-Com® in place (however this was not further investigated in subsequent follow-ups). In summary, this study demonstrated that not only is IPAP < EPAP equally effective, but it may also be more comfortable for patients and pave the way for increased CPAP adherence.

In another study, the addition of V.-Com® to the CPAP circuit during split-night titrations was able to resolve TECSA in 100% of the occurrences (Noah et al., 2024). In all 13 participants where TECSA was observed (~1% of the study cohort), overnight V.-Com® placement systematically reduced the central apnea index from 17.3 ± 11.0 events/h (pre-V.-Com® mean ± SD) to 1.5 ± 1.7 events/h. This effect was likely mediated by V.-Com® reducing IPAP and consequently tidal volume (Bishop et al., 1978; Meza et al., 1998; Johnson and Johnson, 2005; Skatrud and Dempsey, 1983). Most likely, this helped stabilize breathing by driving end-tidal CO2 above the apnea threshold.

Thus, in conclusion, V.-Com® maintained or improved therapy, and, unlike IPAP > EPAP, slightly enhanced adherence, reduced leak, and eliminated TECSA. However, it is important to note that V.-Com® should be tested in a larger population and with a patient blinding intervention to ensure unbiased results. In addition, V.-Com® was evaluated using a 6 cmH2O pressure range around the P90/P95 (minimum and maximum pressure were set 2 cmH2O below and 4 cmH2O above the P90/P95, respectively). Future studies should assess whether V.-Com® affects OSA outcomes when wider PAP ranges are used and optimal P90/P95 is not already known, to confirm its usefulness in more real-world settings.

7 Evaluating lower inspiratory and expiratory pressures to improve pap adherence

KPAP™, derived from the Greek word Kairos, meaning “at the right time”, is a new pressure delivery algorithm providing full therapeutic pressure only at end-expiration, namely when the upper airway is more susceptible to narrowing or collapse. KPAP™, manufactured by SleepRes, takes further the concept of V.-Com® by decreasing IPAP in the circuit to enhance comfort, featuring two sequential, flow-dependent reductions in pressure that begin at the initiation of inspiration and continue approximately halfway through expiration, before gradually returning to therapeutic pressure (Figure 2). The first pressure drop can be set at 1 or 2 cmH2O, while the second drop occurs at peak inspiratory flow, and can be adjusted to 1, 2, or 3 cmH2O. These combined reductions can reach a maximum total drop of 5 cmH2O, but IPAP (and part of EPAP) is never allowed to fall below 5 cmH2O. For example, if a patient's therapeutic pressure is set to 8 cmH2O, the maximum combined PAP drop would be 3 cmH2O (e.g., 2 + 1 cmH2O); similarly, if the baseline pressure is 9 cmH2O, the maximum PAP drop would be 4 cmH2O (i.e., 2 + 2 cmH2O), while it could be up to 5 cmH2O for baseline pressures of 10 cmH2O or above. The threshold of a 5 cmH2O maximum total drop was established based on preliminary observations from a local cohort of 150 patients, where comfort levels rose as IPAP was decreased, with subjective benefit increasing up to and plateauing at ~5 cmH2O. There was also concern that in some patients, pressure drops larger than 5 cmH2O might increase the frequency of disordered breathing events.

In a randomized, single-blinded, controlled trial, the effect of KPAP™ on OSA severity and patient's subjective comfort was investigated (White et al., 2024). KPAP™ was compared to CPAP in a randomized, crossover, split night design (half the night on KPAP™ and half on CPAP) to assess differences in residual AHI in 48 prospective participants with established OSA and evidence of at least 5 h of nightly APAP usage at home. Therapeutic CPAP pressure and baseline KPAP™ pressure were set to the P90/P95 determined by home APAP + 1 cmH2O. The study concluded that efficacy on residual events with KPAP™ was not inferior vs. with CPAP (mean difference [95%CI]; −0.6 [−10, −0.2] events/h in favor of KPAP™, P = 0.005; results were adjusted for supine sleep time, CPAP setting, mask type, period and sequence; Figure 7), confirming the findings observed with V.-Com®. Also similarly to V.-Com®, unintentional leak was reduced by roughly 40% on KPAP™ vs. CPAP.

Figure 7
www.frontiersin.org

Figure 7. OSA severity metrics in a trial examining the effect of Kairos positive airway pressure (KPAP™) vs. continuous PAP (CPAP) in 48 participants (individual data are illustrated in figure) (White et al., 2024). AHI3a indicates the apnea and hypopnea index when hypopneas were scored as a ≥30% reduction in flow plus a 3% oxyhemoglobin desaturation and/or the presence of a respiratory-related arousal. AHI4 was the AHI with hypopneas associated with 4% desaturations. In this trial, the effect of CPAP vs. KPAP™ on AHI3a was the primary outcome, whereas AHI4 was assessed as part of sensitivity analyses. The bars in each panel are the mean values on the corresponding treatment arm. Reproduced with permission.

To assess differences in comfort, CPAP at baseline pressures of 9 and 13 cmH2O vs. KPAP™ at the same therapeutic pressures with various drops—tailored to the baseline pressure—were administered in random order to 150 newly-diagnosed with OSA, CPAP-naïve participants (White et al., 2024). The study was carried out during wakefulness, during an in-office visit. After CPAP and KPAP™ administration, participants were asked to choose which treatment they found most comfortable. At a baseline pressure of 9 cmH2O, 69% of participants preferred KPAP™ (administered with pressure drops of 2 + 2 cmH2O; P < 0.001; Figure 8, top) over CPAP. At a baseline pressure of 13 cmH2O, 84% of participants preferred KPAP™ (administered with pressure drops of 2+3 cmH2O; P < 0.001; Figure 8, bottom). The study also assessed how many of the patients who initially preferred CPAP in the first round of choices found lower KPAP™ drops more comfortable. Eventually, overall, 93% of participants at 9 cmH2O and 95% at 13 cmH2O chose KPAP™ with one of the pressure drops over CPAP. This study had many limitations, including the absence of a wash-out period between treatments, or between home CPAP and the study night, and the sole focus on acute data. In practice, KPAP™ treatment could have benefitted from a residual effect of previous CPAP use (carryover effect) (Vroegop et al., 2015). However, no independent effect of sequence or period was observed, and AHI was systematically lower on KPAP™ than CPAP, indicating a low likelihood of a carryover effect.

Figure 8
www.frontiersin.org

Figure 8. The pie charts illustrate participant preferences for Kairos positive airway pressure (KPAP™) vs. continuous PAP (CPAP) during a randomized office procedure conducted during wakefulness (White et al., 2024). Both KPAP™ and CPAP were administered at the baseline pressures of 9 cmH2O (first) and 13 cmH2O (later). In the KPAP arm, when the baseline pressure was 9 cmH2O, there was a 2 cmH2O drop at the start of inspiration and a subsequent drop of 2 cmH2O at peak inspiration [referred to as KPAP™ (2/2) in figure]. Similarly, at the baseline pressure of 13 cmH2O, pressure reductions were 2 and 3 cmH2O [KPAP™ (2/3) in figure]. Participants laid supine during PAP administration and raised their hand to indicate whether they preferred KPAP™ or CPAP. Results indicated a significant preference for KPAP™ at both baseline pressures (statistical significance illustrated by asterisks between treatments). Reproduced with permission.

In summary, KPAP™ confirmed and extended the preliminary findings observed with V.-Com®, including: (1) reducing IPAP by up to 5 cmH2O does not compromise upper airway patency, (2) targeting end-expiration as “the right time” to address pharyngeal narrowing appears to be an effective strategy, and (3) a lower IPAP is perceived as more comfortable, possibly due to a more natural breathing sensation (Figure 5). In addition, in consideration of the shared mechanism of action, it is possible that KPAP™ could have the same effect as V.-Com® in solving TECSA. However, this will need to be confirmed in appropriate trials.

In addition, these findings will need to be confirmed in a larger cohort, with proper washout periods, and over longer treatment durations. Unselected OSA populations (i.e., not limited to individuals with prior good PAP adherence) will also need to be studied to evaluate the effect of IPAP-lowering interventions in those with known PAP intolerance or with factors that may affect it, such as specific endotypes like low arousal threshold. Finally, adherence data during long-term administration will also need to be collected.

Of note, since the impact of pressure on alveolar cells has been identified as a potential mechanism of increased systemic inflammation and adverse cardiovascular outcomes (Peker et al., 2024; Gottlieb et al., 2022; Shah et al., 2023), evaluating the long-term cardiovascular effects of a treatment delivering lower inspiratory pressure to the lungs could be highly valuable. Such an approach might not only reduce the risk of pressure-induced inflammatory responses but also provide new insights into optimizing PAP therapy to better prevent chronic adverse outcomes. Regardless, confirming that KPAP™ has at least the same effect of CPAP in reducing systemic blood pressure (Gottlieb et al., 2014; Messineo et al., 2024) and sleepiness (Pepin et al., 2009b; Weaver et al., 2007) would be valuable.

8 Conclusions

While CPAP has remained the cornerstone of treatment for OSA for over four decades, adherence continues to be a significant barrier to its long-term success. Despite technological improvements such as more comfortable mask designs, humidifiers, and pressure-relief algorithms, adherence rates remain suboptimal. Social factors, altered OSA endotypes, side effects and perception of lack of a therapeutic effect are some of the persistent challenges that ultimately lead to limited CPAP effectiveness.

Emerging solutions such as V.-Com® and KairosPAP™, which offers a novel approach by reducing pressure at key points in the breathing cycle, demonstrate promising improvements in patient comfort without sacrificing efficacy. As these preliminary findings suggest, addressing specific comfort issues such as pressure intolerance may enhance long-term adherence. However, more research is necessary to assess the broader impact of KPAP™ and other innovations on patient outcomes and adherence over time. These results emphasize the need for continued advancements in PAP therapy to overcome the longstanding obstacles to patient compliance with the goal of improved outcomes in patients with obstructive sleep apnea.

Data availability statement

The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author.

Author contributions

LM: Writing – original draft, Writing – review & editing. DW: Writing – review & editing. WN: Writing – review & editing.

Funding

The author(s) declare that no financial support was received for the research, authorship, and/or publication of this article.

Conflict of interest

LM received industry grants from Apnimed, Inc and Prosomnus, and is the consulting for SleepRes, Inc. as a medical director, and Apnimed, Inc. DW is a consultant for Bairitone, Cerebra Health, Cryosa, Mosanna, Onera, Philips Respironics, Resonea, Xtrodes, Apnimed, Inc., and SleepRes, Inc. WN has ownership in SleepRes, Inc.

Generative AI statement

The author(s) declare that no Generative AI was used in the creation of this manuscript.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

Alsabbagh, M. H., Lemstra, M., Eurich, D., Lix, L. M., Wilson, T. W., Watson, E., et al. (2014). Socioeconomic status and nonadherence to antihypertensive drugs: a systematic review and meta-analysis. Value Health. 17, 288–296. doi: 10.1016/j.jval.2013.11.011

PubMed Abstract | Crossref Full Text | Google Scholar

Anwar, A. I., Byrne, S., Sharma, A., Sands, S., Wellman, A., Redeker, N. S., et al. (2024). Novel physiologic predictors of positive airway pressure effectiveness (NICEPAP) study: rationale, design and methods. Sleep Breath. 28, 2005–2015. doi: 10.1007/s11325-024-03099-w

PubMed Abstract | Crossref Full Text | Google Scholar

Bachour, A., Vitikainen, P., and Maasilta, P. (2016). Rates of initial acceptance of PAP masks and outcomes of mask switching. Sleep Breath. 20, 733–738. doi: 10.1007/s11325-015-1292-x

PubMed Abstract | Crossref Full Text | Google Scholar

Bakker, J., Campbell, A., and Neill, A. (2010). Randomized controlled trial comparing flexible and continuous positive airway pressure delivery: effects on compliance, objective and subjective sleepiness and vigilance. Sleep 33, 523–529. doi: 10.1093/sleep/33.4.523

PubMed Abstract | Crossref Full Text | Google Scholar

Baltzan, M. A., Elkholi, O., and Wolkove, N. (2009). Evidence of interrelated side effects with reduced compliance in patients treated with nasal continuous positive airway pressure. Sleep Med. 10, 198–205. doi: 10.1016/j.sleep.2007.12.005

PubMed Abstract | Crossref Full Text | Google Scholar

Barach, A. L., and Eckman, M. (1947). Studies on positive pressure respiration; effect of continuous pressure breathing on arterial blood gases at high altitude. J. Aviat. Med. 18, 139–148.

PubMed Abstract | Google Scholar

Benjafield, A. V., Oldstone, L. M., Willes, L. A., Kelly, C., Nunez, C. M., Malhotra, A., et al. (2021). Positive airway pressure therapy adherence with mask resupply: a propensity-matched analysis. J Clin Med. 10:720. doi: 10.3390/jcm10040720

PubMed Abstract | Crossref Full Text | Google Scholar

Benjafield, A. V., Pepin, J. L., Valentine, K., Cistulli, P. A., Woehrle, H., Nunez, C. M., et al. (2019). Compliance after switching from CPAP to bilevel for patients with non-compliant OSA: big data analysis. BMJ Open Respir. Res. 6:e000380. doi: 10.1136/bmjresp-2018-000380

PubMed Abstract | Crossref Full Text | Google Scholar

Bishop, B., Hirsch, J., and Thursby, M. (1978). Volume, flow, and timing of each breath during positive-pressure breathing in man. J. Appl. Physiol. Respir. Environ. Exerc. Physiol. 45, 495–501. doi: 10.1152/jappl.1978.45.4.495

PubMed Abstract | Crossref Full Text | Google Scholar

Borel, J. C., Tamisier, R., Dias-Domingos, S., Sapene, M., Martin, F., Stach, B., et al. (2013). Type of mask may impact on continuous positive airway pressure adherence in apneic patients. PLoS ONE. 8:e64382. doi: 10.1371/journal.pone.0064382

PubMed Abstract | Crossref Full Text | Google Scholar

Brostrom, A., Arestedt, K. F., Nilsen, P., Stromberg, A., Ulander, M., Svanborg, E., et al. (2010). The side-effects to CPAP treatment inventory: the development and initial validation of a new tool for the measurement of side-effects to CPAP treatment. J. Sleep Res. 19, 603–611. doi: 10.1111/j.1365-2869.2010.00825.x

PubMed Abstract | Crossref Full Text | Google Scholar

Burger, C. D., Stanson, A. W., Daniels, B. K., Sheedy, P. F., and Shepard, J. W. (1992). Fast-CT evaluation of the effect of lung volume on upper airway size and function in normal men. Am. Rev. Respir. Dis. 146, 335–339. doi: 10.1164/ajrccm/146.2.335

PubMed Abstract | Crossref Full Text | Google Scholar

Campana, L. M., Malhotra, A., Suki, B., Hess, L., Israel, E., Smales, E., et al. (2013). The effect of lung stretch during sleep on airway mechanics in overweight and obese asthma. Respir. Physiol. Neurobiol. 185, 304–312. doi: 10.1016/j.resp.2012.09.013

PubMed Abstract | Crossref Full Text | Google Scholar

Carlucci, A., Ceriana, P., Mancini, M., Cirio, S., Pierucci, P., D'Artavilla Lupo, N., et al. (2015). Efficacy of bilevel-auto treatment in patients with obstructive sleep apnea not responsive to or intolerant of continuous positive airway pressure ventilation. J. Clin. Sleep Med. 11, 981–985. doi: 10.5664/jcsm.5008

PubMed Abstract | Crossref Full Text | Google Scholar

Cheng, W. J., Finnsson, E., Agustsson, J. S., Sands, S. A., and Hang, L. W. (2024). Continuous positive airway pressure and adherence in patients with different endotypes of obstructive sleep apnea. J. Sleep Res. 33:e13999. doi: 10.1111/jsr.13999

PubMed Abstract | Crossref Full Text | Google Scholar

Chihara, Y., Tsuboi, T., Hitomi, T., Azuma, M., Murase, K., Toyama, Y., et al. (2013). Flexible positive airway pressure improves treatment adherence compared with auto-adjusting PAP. Sleep 36, 229–236. doi: 10.5665/sleep.2378

PubMed Abstract | Crossref Full Text | Google Scholar

Cistulli, P. A., Armitstead, J., Pepin, J. L., Woehrle, H., Nunez, C. M., Benjafield, A., et al. (2019). Short-term CPAP adherence in obstructive sleep apnea: a big data analysis using real world data. Sleep Med. 59, 114–116. doi: 10.1016/j.sleep.2019.01.004

PubMed Abstract | Crossref Full Text | Google Scholar

Cramer, J. A. A. (2004). systematic review of adherence with medications for diabetes. Diabetes Care. 27, 1218–1224. doi: 10.2337/diacare.27.5.1218

PubMed Abstract | Crossref Full Text | Google Scholar

Dawson, S. V., and Elliott, E. A. (1980). Use of the choke point in the prediction of flow limitation in elastic tubes. Fed. Proc. 39, 2765–2770.

Google Scholar

Devouassoux, G., Levy, P., Rossini, E., Pin, I., Fior-Gozlan, M., Henry, M., et al. (2007). Sleep apnea is associated with bronchial inflammation and continuous positive airway pressure-induced airway hyperresponsiveness. J. Allergy Clin. Immunol. 119, 597–603. doi: 10.1016/j.jaci.2006.11.638

PubMed Abstract | Crossref Full Text | Google Scholar

Dolan, D. C., Okonkwo, R., Gfullner, F., Hansbrough, J. R., Strobel, R. J., Rosenthal, L., et al. (2009). Longitudinal comparison study of pressure relief (C-Flex) vs. CPAP in OSA patients. Sleep Breath. 13, 73–77. doi: 10.1007/s11325-008-0199-1

PubMed Abstract | Crossref Full Text | Google Scholar

Duong, M., Jayaram, L., Camfferman, D., Catcheside, P., Mykytyn, I., McEvoy, R. D., et al. (2005). Use of heated humidification during nasal CPAP titration in obstructive sleep apnoea syndrome. Eur. Respir. J. 26, 679–685. doi: 10.1183/09031936.05.00131504

PubMed Abstract | Crossref Full Text | Google Scholar

Farney, R. J., Hete, B., White, D. P., Sundar, K. M., Lannom, W. D., Pucket, M. A., et al. (2024). Reducing inspiratory positive airway pressure (IPAP) to treat obstructive sleep apnea provides equivalent therapy, improves comfort, and reduces unintentional leak. J. Sleep Disord. Ther. 2024:13. doi: 10.35248/2167-0277.24.13.533

Crossref Full Text | Google Scholar

Ferguson, G. T., and Gilmartin, M. (1995). CO2 rebreathing during BiPAP ventilatory assistance. Am. J. Respir. Crit. Care Med. 151, 1126–1135. doi: 10.1164/ajrccm.151.4.7697242

PubMed Abstract | Crossref Full Text | Google Scholar

Fujita, Y., Yamauchi, M., and Muro, S. (2024). Assessment and management of continuous positive airway pressure therapy in patient with obstructive sleep apnea. Respir. Investig. 62, 645–650. doi: 10.1016/j.resinv.2024.05.004

PubMed Abstract | Crossref Full Text | Google Scholar

Galetke, W., Nothofer, E., Priegnitz, C., Anduleit, N., and Randerath, W. (2016). Effect of a heated breathing tube on efficacy, adherence and side effects during continuous positive airway pressure therapy in obstructive sleep apnea. Respiration 91, 18–25. doi: 10.1159/000442052

PubMed Abstract | Crossref Full Text | Google Scholar

Gay, P. C., Herold, D. L., and Olson, E. J. A. (2003). randomized, double-blind clinical trial comparing continuous positive airway pressure with a novel bilevel pressure system for treatment of obstructive sleep apnea syndrome. Sleep 26, 864–869. doi: 10.1093/sleep/26.7.864

PubMed Abstract | Crossref Full Text | Google Scholar

Genta, P. R., Edwards, B. A., Sands, S. A., Owens, R. L., Butler, J. P., Loring, S. H., et al. (2016). Tube law of the pharyngeal airway in sleeping patients with obstructive sleep apnea. Sleep. 39, 337–343. doi: 10.5665/sleep.5440

PubMed Abstract | Crossref Full Text | Google Scholar

Genta, P. R., Kaminska, M., Edwards, B. A., Ebben, M. R., Krieger, A. C., Tamisier, R., et al. (2020). The importance of mask selection on continuous positive airway pressure outcomes for obstructive sleep apnea. an official american thoracic society workshop report. Ann. Am. Thorac. Soc. 17, 1177–1185. doi: 10.1513/AnnalsATS.202007-864ST

PubMed Abstract | Crossref Full Text | Google Scholar

Gentina, T., Bailly, S., Jounieaux, F., Verkindre, C., Broussier, P. M., Guffroy, D., et al. (2019). Marital quality, partner's engagement and continuous positive airway pressure adherence in obstructive sleep apnea. Sleep Med. 55, 56–61. doi: 10.1016/j.sleep.2018.12.009

PubMed Abstract | Crossref Full Text | Google Scholar

Gerves-Pinquie, C., Bailly, S., Goupil, F., Pigeanne, T., Launois, S., Leclair-Visonneau, L., et al. (2022). Positive airway pressure adherence, mortality, and cardiovascular events in patients with sleep apnea. Am. J. Respir. Crit. Care Med. 206, 1393–1404. doi: 10.1164/rccm.202202-0366OC

PubMed Abstract | Crossref Full Text | Google Scholar

Getnet, A., Woldeyohannes, S. M., Bekana, L., Mekonen, T., Fekadu, W., Menberu, M., et al. (2016). Antiepileptic drug nonadherence and its predictors among people with epilepsy. Behav. Neurol. 2016:3189108. doi: 10.1155/2016/3189108

PubMed Abstract | Crossref Full Text | Google Scholar

Ghadiri, M., and Grunstein, R. R. (2020). Clinical side effects of continuous positive airway pressure in patients with obstructive sleep apnoea. Respirology 25, 593–602. doi: 10.1111/resp.13808

PubMed Abstract | Crossref Full Text | Google Scholar

Gold, A. R., and Schwartz, A. R. (1996). The pharyngeal critical pressure. The whys and hows of using nasal continuous positive airway pressure diagnostically. Chest 110, 1077–1088. doi: 10.1378/chest.110.4.1077

PubMed Abstract | Crossref Full Text | Google Scholar

Gong, Y., and Sankari, A. (2024). Noninvasive Ventilation. Treasure Island, FL: StatPearls.

Google Scholar

Goossens, L., Leibold, N., Peeters, R., Esquivel, G., Knuts, I., Backes, W., et al. (2014). Brainstem response to hypercapnia: a symptom provocation study into the pathophysiology of panic disorder. J. Psychopharmacol. 28, 449–456. doi: 10.1177/0269881114527363

PubMed Abstract | Crossref Full Text | Google Scholar

Gottlieb, D. J., Lederer, D. J., Kim, J. S., Tracy, R. P., Gao, S., Redline, S., et al. (2022). Effect of positive airway pressure therapy of obstructive sleep apnea on circulating Angiopoietin-2. Sleep Med. 96, 119–121. doi: 10.1016/j.sleep.2022.05.007

PubMed Abstract | Crossref Full Text | Google Scholar

Gottlieb, D. J., Punjabi, N. M., Mehra, R., Patel, S. R., Quan, S. F., Babineau, D. C., et al. (2014). CPAP versus oxygen in obstructive sleep apnea. N. Engl. J. Med. 370, 2276–2285. doi: 10.1056/NEJMoa1306766

PubMed Abstract | Crossref Full Text | Google Scholar

Gugger, M., and Vock, P. (1992). Effect of reduced expiratory pressure on pharyngeal size during nasal positive airway pressure in patients with sleep apnoea: evaluation by continuous computed tomography. Thorax 47, 809–813. doi: 10.1136/thx.47.10.809

PubMed Abstract | Crossref Full Text | Google Scholar

Gulati, A., Oscroft, N., Chadwick, R., Ali, M., and Smith, I. (2015). The impact of changing people with sleep apnea using CPAP less than 4 h per night to a Bi-level device. Respir. Med. 109, 778–783. doi: 10.1016/j.rmed.2015.01.020

PubMed Abstract | Crossref Full Text | Google Scholar

Hayes, M. J., McGregor, F. B., Roberts, D. N., Schroter, R. C., and Pride, N. B. (1995). Continuous nasal positive airway pressure with a mouth leak: effect on nasal mucosal blood flux and nasal geometry. Thorax 50, 1179–1182. doi: 10.1136/thx.50.11.1179

PubMed Abstract | Crossref Full Text | Google Scholar

Heinzer, R., White, D. P., Malhotra, A., Lo, Y. L., Dover, L., Stevenson, K. E., et al. (2008). Effect of expiratory positive airway pressure on sleep disordered breathing. Sleep 31, 429–432. doi: 10.1093/sleep/31.3.429

PubMed Abstract | Crossref Full Text | Google Scholar

Heinzer, R. C., Stanchina, M. L., Malhotra, A., Fogel, R. B., Patel, S. R., Jordan, A. S., et al. (2005). Lung volume and continuous positive airway pressure requirements in obstructive sleep apnea. Am. J. Respir. Crit. Care Med. 172, 114–117. doi: 10.1164/rccm.200404-552OC

PubMed Abstract | Crossref Full Text | Google Scholar

Heinzer, R. C., Stanchina, M. L., Malhotra, A., Jordan, A. S., Patel, S. R., Lo, Y. L., et al. (2006). Effect of increased lung volume on sleep disordered breathing in patients with sleep apnoea. Thorax 61, 435–439. doi: 10.1136/thx.2005.052084

PubMed Abstract | Crossref Full Text | Google Scholar

Hoffstein, V., Zamel, N., and Phillipson, E. A. (1984). Lung volume dependence of pharyngeal cross-sectional area in patients with obstructive sleep apnea. Am. Rev. Respir. Dis. 130, 175–178. doi: 10.1164/arrd.1984.130.2.175

PubMed Abstract | Crossref Full Text | Google Scholar

Hsu, D. Y., Cheng, Y. L., Bien, M. Y., and Lee, H. C. (2015). Development of a method for manufacturing customized nasal mask cushion for CPAP therapy. Australas. Phys. Eng. Sci. Med. 38, 657–664. doi: 10.1007/s13246-015-0383-0

PubMed Abstract | Crossref Full Text | Google Scholar

Hudgel, D. W., and Devadatta, P. (1984). Decrease in functional residual capacity during sleep in normal humans. J. Appl. Physiol. Respir. Environ. Exerc. Physiol. 57, 1319–1322. doi: 10.1152/jappl.1984.57.5.1319

PubMed Abstract | Crossref Full Text | Google Scholar

Hussin, R., Sharif, S., Nabialek, M., Zamree Abd Rahim, S., Khushairi, M. T. M., Suhaimi, M. A., et al. (2021). Hybrid mold: comparative study of rapid and hard tooling for injection molding application using metal epoxy composite (MEC). Materials 14:665. doi: 10.3390/ma14030665

PubMed Abstract | Crossref Full Text | Google Scholar

Hwang, D., Chang, J. W., Benjafield, A. V., Crocker, M. E., Kelly, C., Becker, K. A., et al. (2018). Effect of telemedicine education and telemonitoring on continuous positive airway pressure adherence. The tele-OSA randomized trial. Am. J. Respir. Crit. Care Med. 197, 117–126. doi: 10.1164/rccm.201703-0582OC

PubMed Abstract | Crossref Full Text | Google Scholar

Ishak, A., Ramsay, M., Hart, N., and Steier, J. B. P. A. P. (2020). is an effective second-line therapy for obese patients with OSA failing regular CPAP: a prospective observational cohort study. Respirology 25, 443–448. doi: 10.1111/resp.13674

PubMed Abstract | Crossref Full Text | Google Scholar

Johnson, K. G., and Johnson, D. C. (2005). Bilevel positive airway pressure worsens central apneas during sleep. Chest 128, 2141–2150. doi: 10.1378/chest.128.4.2141

PubMed Abstract | Crossref Full Text | Google Scholar

Juhasz, J., Becker, H., Cassel, W., Rostig, S., and Peter, J. H. (2001). Proportional positive airway pressure: a new concept to treat obstructive sleep apnoea. Eur. Respir. J. 17, 467–473. doi: 10.1183/09031936.01.17304670

PubMed Abstract | Crossref Full Text | Google Scholar

Kairaitis, K., Byth, K., Parikh, R., Stavrinou, R., Wheatley, J. R., Amis, T. C., et al. (2007). Tracheal traction effects on upper airway patency in rabbits: the role of tissue pressure. Sleep 30, 179–186. doi: 10.1093/sleep/30.2.179

PubMed Abstract | Crossref Full Text | Google Scholar

Koutsourelakis, I., Vagiakis, E., Perraki, E., Karatza, M., Magkou, C., Kopaka, M., et al. (2011). Nasal inflammation in sleep apnoea patients using CPAP and effect of heated humidification. Eur. Respir. J. 37, 587–594. doi: 10.1183/09031936.00036910

PubMed Abstract | Crossref Full Text | Google Scholar

Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., et al. (1993). Objective measurement of patterns of nasal CPAP use by patients with obstructive sleep apnea. Am. Rev. Respir. Dis. 147, 887–895. doi: 10.1164/ajrccm/147.4.887

PubMed Abstract | Crossref Full Text | Google Scholar

Kryger, M. H., Berry, R. B., and Massie, C. A. (2011). Long-term use of a nasal expiratory positive airway pressure (EPAP) device as a treatment for obstructive sleep apnea (OSA). J Clin Sleep Med. 7, 449–53B. doi: 10.5664/JCSM.1304

PubMed Abstract | Crossref Full Text | Google Scholar

Kuhn, E., Schwarz, E. I., Bratton, D. J., Rossi, V. A., and Kohler, M. (2017). Effects of CPAP and mandibular advancement devices on health-related quality of life in osa: a systematic review and meta-analysis. Chest 151, 786–794. doi: 10.1016/j.chest.2017.01.020

PubMed Abstract | Crossref Full Text | Google Scholar

Labarca, G., Dreyse, J., Drake, L., Jorquera, J., and Barbe, F. (2020). Efficacy of continuous positive airway pressure (CPAP) in the prevention of cardiovascular events in patients with obstructive sleep apnea: Systematic review and meta-analysis. Sleep Med. Rev. 52:101312. doi: 10.1016/j.smrv.2020.101312

PubMed Abstract | Crossref Full Text | Google Scholar

Lebret, M., Arnol, N., Martinot, J. B., Lambert, L., Tamisier, R., Pepin, J. L., et al. (2018). Determinants of unintentional leaks during CPAP treatment in OSA. Chest 153, 834–842. doi: 10.1016/j.chest.2017.08.017

PubMed Abstract | Crossref Full Text | Google Scholar

Levy, P., Pepin, J. L., and Ferretti, G. (1994). The dynamics of pharyngeal structures in obstructive sleep apnea (during spontaneous, continuous positive pressure and BiPAP ventilation). Neurophysiol. Clin. 24, 227–248. doi: 10.1016/S0987-7053(05)80187-X

PubMed Abstract | Crossref Full Text | Google Scholar

Lewis, K. E., Seale, L., Bartle, I. E., Watkins, A. J., and Ebden, P. (2004). Early predictors of CPAP use for the treatment of obstructive sleep apnea. Sleep 27, 134–138. doi: 10.1093/sleep/27.1.134

PubMed Abstract | Crossref Full Text | Google Scholar

Loh, G., Shieck, K., Hostler, J., Khramtsov, A., Foster, B., Puderbaugh, A., et al. (2014). Flex-settings increase central apneas and reduce mask leak but have no effect on overall compliance. Chest 146:954A. doi: 10.1378/chest.1995089

Crossref Full Text | Google Scholar

Malhotra, A., Bertisch, S., and Wellman, A. (2008). Complex sleep apnea: it isn't really a disease. J. Clin. Sleep Med. 4, 406–408. doi: 10.5664/jcsm.27273

Crossref Full Text | Google Scholar

Massie, C. A., Hart, R. W., Peralez, K., and Richards, G. N. (1999). Effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure. Chest 116, 403–408. doi: 10.1378/chest.116.2.403

PubMed Abstract | Crossref Full Text | Google Scholar

McDaid, C., Duree, K. H., Griffin, S. C., Weatherly, H. L., Stradling, J. R., Davies, R. J., et al. (2009). A systematic review of continuous positive airway pressure for obstructive sleep apnoea-hypopnoea syndrome. Sleep Med. Rev. 13, 427–436. doi: 10.1016/j.smrv.2009.02.004

PubMed Abstract | Crossref Full Text | Google Scholar

McEvoy, R. D., Antic, N. A., Heeley, E., Luo, Y., Ou, Q., Zhang, X., et al. (2016). CPAP for prevention of cardiovascular events in obstructive sleep apnea. N. Engl. J. Med. 375, 919–931. doi: 10.1056/NEJMoa1606599

PubMed Abstract | Crossref Full Text | Google Scholar

Messineo, L., Bakker, J. P., Cronin, J., Yee, J., and White, D. P. (2024a). Obstructive sleep apnea and obesity: a review of epidemiology, pathophysiology and the effect of weight-loss treatments. Sleep Med. Rev. 78:101996. doi: 10.1016/j.smrv.2024.101996

PubMed Abstract | Crossref Full Text | Google Scholar

Messineo, L., and Eckert, D. J. (2022). “Obstructive sleep apnea phenotyping to understand pathophysiology and improve treatment and outcomes,” in Encyclopedia of Respiratory Medicine, ed. S. M. Janes (San Diego, CA: Academic Press), 22–33.

Google Scholar

Messineo, L., Hete, B., Diesem, R., and Noah, W. (2024b). Circuit-dependent carbon dioxide rebreathing during continuous positive airway pressure. Sleep Med. 121, 42–47. doi: 10.1016/j.sleep.2024.05.053

PubMed Abstract | Crossref Full Text | Google Scholar

Messineo, L., Joosten, S., and Perger, E. (2023). Mechanisms relating to sleeping position to the endotypes of sleep disordered breathing. Curr. Opin. Pulm. Med. 29, 543–549. doi: 10.1097/MCP.0000000000001004

PubMed Abstract | Crossref Full Text | Google Scholar

Messineo, L., Sands, S. A., and Labarca, G. (2024c). Hypnotics on obstructive sleep apnea severity and endotypes: a systematic review and meta-analysis. Am. J. Respir. Crit. Care Med. doi: 10.1164/rccm.202403-0501OC. [Epub ahead of print].

PubMed Abstract | Crossref Full Text | Google Scholar

Messineo, L., Sands, S. A., Schmickl, C., Labarca, G., Hu, W. H., Esmaeili, N., et al. (2024). Treatment of sleep apnea and reduction in blood pressure: the role of heart rate response and hypoxic burden. Hypertension 81, 1106–1114. doi: 10.1161/HYPERTENSIONAHA.123.22444

PubMed Abstract | Crossref Full Text | Google Scholar

Meyer, T. J., Pressman, M. R., Benditt, J., McCool, F. D., Millman, R. P., Natarajan, R., et al. (1997). Air leaking through the mouth during nocturnal nasal ventilation: effect on sleep quality. Sleep 20, 561–569. doi: 10.1093/sleep/20.7.561

PubMed Abstract | Crossref Full Text | Google Scholar

Meza, S., Mendez, M., Ostrowski, M., and Younes, M. (1998). Susceptibility to periodic breathing with assisted ventilation during sleep in normal subjects. J. Appl. Physiol. 85, 1929–1940. doi: 10.1152/jappl.1998.85.5.1929

PubMed Abstract | Crossref Full Text | Google Scholar

Morrone, E., Giordano, A., Carli, S., Visca, D., Rossato, F., Godio, M., et al. (2020). Something is changing in adherence to CPAP therapy: real world data after 1 year of treatment in patients with obstructive sleep apnoea. Eur. Respir. J. 55 doi: 10.1183/13993003.01419-2019

PubMed Abstract | Crossref Full Text | Google Scholar

Mulgrew, A. T., Lawati, N. A., Ayas, N. T., Fox, N., Hamilton, P., Cortes, L., et al. (2010). Residual sleep apnea on polysomnography after 3 months of CPAP therapy: clinical implications, predictors and patterns. Sleep Med. 11, 119–125. doi: 10.1016/j.sleep.2009.05.017

PubMed Abstract | Crossref Full Text | Google Scholar

Neill, A. M., Wai, H. S., Bannan, S. P., Beasley, C. R., Weatherall, M., Campbell, A. J., et al. (2003). Humidified nasal continuous positive airway pressure in obstructive sleep apnoea. Eur. Respir. J. 22, 258–262. doi: 10.1183/09031936.03.00035603

PubMed Abstract | Crossref Full Text | Google Scholar

Neuzeret, P. C., and Morin, L. (2017). Impact of different nasal masks on CPAP therapy for obstructive sleep apnea: a randomized comparative trial. Clin. Respir. J. 11, 990–998. doi: 10.1111/crj.12452

PubMed Abstract | Crossref Full Text | Google Scholar

Nilius, G., Domanski, U., Franke, K. J., and Ruhle, K. H. (2008). Impact of a controlled heated breathing tube humidifier on sleep quality during CPAP therapy in a cool sleeping environment. Eur. Respir. J. 31, 830–836. doi: 10.1183/09031936.00161806

PubMed Abstract | Crossref Full Text | Google Scholar

Noah, W. H., Messineo, L., Hete, B., Thompson, E., White, D. P., Farney, R. J., et al. (2024). Treatment-emergent central sleep apnea resolves with lower inspiratory pressure. J. Clin. Sleep Med.

PubMed Abstract | Google Scholar

Owens, R. L., Edwards, B. A., Sands, S. A., Butler, J. P., Eckert, D. J., White, D. P., et al. (2012). Upper airway collapsibility and patterns of flow limitation at constant end-expiratory lung volume. J. Appl. Physiol. 113, 691–699. doi: 10.1152/japplphysiol.00091.2012

PubMed Abstract | Crossref Full Text | Google Scholar

Owens, R. L., Malhotra, A., Eckert, D. J., White, D. P., and Jordan, A. S. (2010). The influence of end-expiratory lung volume on measurements of pharyngeal collapsibility. J. Appl. Physiol. 108, 445–451. doi: 10.1152/japplphysiol.00755.2009

PubMed Abstract | Crossref Full Text | Google Scholar

Palot, A., Nguyen, X. L., Launois, S., Prigent, A., Graml, A., Aversenq, E., et al. (2023). Effect of switching from continuous to bilevel positive airway pressure on sleep quality in patients with obstructive sleep apnea: the prospective POP IN VAuto study. J. Thorac. Dis. 15, 918–927. doi: 10.21037/jtd-22-825

PubMed Abstract | Crossref Full Text | Google Scholar

Parra, O., Klamburg, J., Xirgu, J., Abad, J., Sala, H., Tomasa, A., et al. (1991). Hygroscopic condenser humidifier as a solution to nasal dryness due to nasal CPAP treatment for obstructive sleep apnea syndrome. Sleep 14, 166–168. doi: 10.1093/sleep/14.2.166

PubMed Abstract | Crossref Full Text | Google Scholar

Parthasarathy, S., Wendel, C., Grandner, M. A., Haynes, P. L., Guerra, S., Combs, D., et al. (2024). Peer-driven intervention for care coordination and adherence promotion for obstructive sleep apnea: a randomized, parallel-group clinical trial. Am. J. Respir. Crit. Care Med. doi: 10.1164/rccm.202309-1594OC. [Epub ahead of print].

PubMed Abstract | Crossref Full Text | Google Scholar

Patel, S. R., Bakker, J. P., Stitt, C. J., Hardy, W., Aloia, M. S., Nouraie, S. M., et al. (2022). Impact of an extended telemonitoring and coaching program on continuous positive airway pressure adherence. Ann. Am. Thorac. Soc. 19, 2070–2076. doi: 10.1513/AnnalsATS.202204-310OC

PubMed Abstract | Crossref Full Text | Google Scholar

Patil, S. P., Ayappa, I. A., Caples, S. M., Kimoff, R. J., Patel, S. R., Harrod, C. G., et al. (2019). Treatment of adult obstructive sleep apnea with positive airway pressure: an american academy of sleep medicine systematic review, meta-analysis, and GRADE assessment. J. Clin. Sleep Med. 15, 301–334. doi: 10.5664/jcsm.7638

PubMed Abstract | Crossref Full Text | Google Scholar

Peker, Y., Celik, Y., Behboudi, A., Redline, S., Lyu, J., Wei, Y., et al. (2024). CPAP may promote an endothelial inflammatory milieu in sleep apnoea after coronary revascularization. EBioMedicine. 101:105015. doi: 10.1016/j.ebiom.2024.105015

PubMed Abstract | Crossref Full Text | Google Scholar

Peker, Y., Glantz, H., Eulenburg, C., Wegscheider, K., Herlitz, J., Thunstrom, E., et al. (2016). Effect of positive airway pressure on cardiovascular outcomes in coronary artery disease patients with nonsleepy obstructive sleep apnea. the RICCADSA randomized controlled trial. Am. J. Respir. Crit. Care Med. 194, 613–620. doi: 10.1164/rccm.201601-0088OC

PubMed Abstract | Crossref Full Text | Google Scholar

Pepin, J. L., Leger, P., Veale, D., Langevin, B., Robert, D., Levy, P. S., et al. (1995). effects of nasal continuous positive airway pressure in sleep apnea syndrome. Study of 193 patients in two French sleep centers. Chest 107, 375–381. doi: 10.1378/chest.107.2.375

PubMed Abstract | Crossref Full Text | Google Scholar

Pepin, J. L., Muir, J. F., Gentina, T., Dauvilliers, Y., Tamisier, R., Sapene, M., et al. (2009a). Pressure reduction during exhalation in sleep apnea patients treated by continuous positive airway pressure. Chest 136, 490–497. doi: 10.1378/chest.08-2646

PubMed Abstract | Crossref Full Text | Google Scholar

Pepin, J. L., Tamisier, R., Baguet, J. P., Lepaulle, B., Arbib, F., Arnol, N., et al. (2016). Fixed-pressure CPAP versus auto-adjusting CPAP: comparison of efficacy on blood pressure in obstructive sleep apnoea, a randomised clinical trial. Thorax 71, 726–733. doi: 10.1136/thoraxjnl-2015-207700

PubMed Abstract | Crossref Full Text | Google Scholar

Pepin, J. L., Viot-Blanc, V., Escourrou, P., Racineux, J. L., Sapene, M., Levy, P., et al. (2009b). Prevalence of residual excessive sleepiness in CPAP-treated sleep apnoea patients: the French multicentre study. Eur. Respir. J. 33, 1062–1067. doi: 10.1183/09031936.00016808

PubMed Abstract | Crossref Full Text | Google Scholar

Rakotonanahary, D., Pelletier-Fleury, N., Gagnadoux, F., and Fleury, B. (2001). Predictive factors for the need for additional humidification during nasal continuous positive airway pressure therapy. Chest 119, 460–465. doi: 10.1378/chest.119.2.460

PubMed Abstract | Crossref Full Text | Google Scholar

Rapoport, D. M. (1996). Methods to stabilize the upper airway using positive pressure. Sleep 19, S123–S130. doi: 10.1093/sleep/19.suppl_9.S123

PubMed Abstract | Crossref Full Text | Google Scholar

Reeves-Hoche, M. K., Hudgel, D. W., Meck, R., Witteman, R., Ross, A., Zwillich, C. W., et al. (1995). Continuous versus bilevel positive airway pressure for obstructive sleep apnea. Am. J. Respir. Crit. Care Med. 151, 443–449. doi: 10.1164/ajrccm.151.2.7842204

PubMed Abstract | Crossref Full Text | Google Scholar

Remmers, J. E., deGroot, W. J., Sauerland, E. K., and Anch, A. M. (1978). Pathogenesis of upper airway occlusion during sleep. J. Appl. Physiol. Respir. Environ. Exerc. Physiol. 44, 931–938. doi: 10.1152/jappl.1978.44.6.931

PubMed Abstract | Crossref Full Text | Google Scholar

Resta, O., Guido, P., Picca, V., Scarpelli, F., and Foschino, M. P. (1999). The role of the expiratory phase in obstructive sleep apnoea. Respir. Med. 93, 190–195. doi: 10.1016/S0954-6111(Schwab et al., 1996)90007-0

Crossref Full Text | Google Scholar

Rosen, C. L., Auckley, D., Benca, R., Foldvary-Schaefer, N., Iber, C., Kapur, V., et al. (2012). A multisite randomized trial of portable sleep studies and positive airway pressure autotitration versus laboratory-based polysomnography for the diagnosis and treatment of obstructive sleep apnea: the HomePAP study. Sleep 35, 757–767. doi: 10.5665/sleep.1870

PubMed Abstract | Crossref Full Text | Google Scholar

Rotenberg, B. W., Murariu, D., and Pang, K. P. (2016). Trends in CPAP adherence over twenty years of data collection: a flattened curve. J. Otolaryngol. Head Neck Surg. 45:43. doi: 10.1186/s40463-016-0156-0

PubMed Abstract | Crossref Full Text | Google Scholar

Rowland, S., Aiyappan, V., Hennessy, C., Catcheside, P., Chai-Coezter, C. L., McEvoy, R. D., et al. (2018). Comparing the efficacy, mask leak, patient adherence, and patient preference of three different CPAP interfaces to treat moderate-severe obstructive sleep apnea. J. Clin. Sleep Med. 14, 101–108. doi: 10.5664/jcsm.6892

PubMed Abstract | Crossref Full Text | Google Scholar

Rowley, J. A., Permutt, S., Willey, S., Smith, P. L., and Schwartz, A. R. (1996). Effect of tracheal and tongue displacement on upper airway airflow dynamics. J. Appl. Physiol. 80, 2171–2178. doi: 10.1152/jappl.1996.80.6.2171

PubMed Abstract | Crossref Full Text | Google Scholar

Ruhle, K. H., Franke, K. J., Domanski, U., and Nilius, G. (2011). Quality of life, compliance, sleep and nasopharyngeal side effects during CPAP therapy with and without controlled heated humidification. Sleep Breath. 15, 479–485. doi: 10.1007/s11325-010-0363-2

PubMed Abstract | Crossref Full Text | Google Scholar

Sanchez-de-la-Torre, M., Gracia-Lavedan, E., Benitez, I. D., Sanchez-de-la-Torre, A., Moncusi-Moix, A., Torres, G., et al. (2023). Adherence to CPAP treatment and the risk of recurrent cardiovascular events: a meta-analysis. JAMA. 330, 1255–1265. doi: 10.1001/jama.2023.17465

PubMed Abstract | Crossref Full Text | Google Scholar

Sanchez-de-la-Torre, M., Sanchez-de-la-Torre, A., Bertran, S., Abad, J., Duran-Cantolla, J., Cabriada, V., et al. (2020). Effect of obstructive sleep apnoea and its treatment with continuous positive airway pressure on the prevalence of cardiovascular events in patients with acute coronary syndrome (ISAACC study): a randomised controlled trial. Lancet Respir Med. 8, 359–367. doi: 10.1016/S2213-2600(Lewis et al., 2004)30271-1

Crossref Full Text | Google Scholar

Sanders, M. H., and Kern, N. (1990). Obstructive sleep apnea treated by independently adjusted inspiratory and expiratory positive airway pressures via nasal mask. Physiologic and clinical implications. Chest 98, 317–324. doi: 10.1378/chest.98.2.317

PubMed Abstract | Crossref Full Text | Google Scholar

Sanders, M. H., and Moore, S. E. (1983). Inspiratory and expiratory partitioning of airway resistance during sleep in patients with sleep apnea. Am. Rev. Respir. Dis. 127, 554–558. doi: 10.1164/arrd.1983.127.5.554

PubMed Abstract | Crossref Full Text | Google Scholar

Sawyer, A. M., Gooneratne, N. S., Marcus, C. L., Ofer, D., Richards, K. C., Weaver, T. E. A., et al. (2011). systematic review of CPAP adherence across age groups: clinical and empiric insights for developing CPAP adherence interventions. Sleep Med. Rev. 15, 343–356. doi: 10.1016/j.smrv.2011.01.003

PubMed Abstract | Crossref Full Text | Google Scholar

Schwab, R. J., Gefter, W. B., Hoffman, E. A., Gupta, K. B., and Pack, A. I. (1993). Dynamic upper airway imaging during awake respiration in normal subjects and patients with sleep disordered breathing. Am. Rev. Respir. Dis. 148, 1385–1400. doi: 10.1164/ajrccm/148.5.1385

PubMed Abstract | Crossref Full Text | Google Scholar

Schwab, R. J., Pack, A. I., Gupta, K. B., Metzger, L. J., Oh, E., Getsy, J. E., et al. (1996). Upper airway and soft tissue structural changes induced by CPAP in normal subjects. Am. J. Respir. Crit. Care Med. 154, 1106–1116. doi: 10.1164/ajrccm.154.4.8887615

PubMed Abstract | Crossref Full Text | Google Scholar

Schwartz, A. R., Smith, P. L., Wise, R. A., Gold, A. R., and Permutt, S. (1988). Induction of upper airway occlusion in sleeping individuals with subatmospheric nasal pressure. J. Appl. Physiol. 64, 535–542. doi: 10.1152/jappl.1988.64.2.535

PubMed Abstract | Crossref Full Text | Google Scholar

Series, F., and Marc, I. (1998). Effects of inspiratory and expiratory positive pressure difference on airflow dynamics during sleep. J. Appl. Physiol. 85, 1855–1862. doi: 10.1152/jappl.1998.85.5.1855

PubMed Abstract | Crossref Full Text | Google Scholar

Shah, A. M., and Wolford, G. (2007). Buying behavior as a function of parametric variation of number of choices. Psychol. Sci. 18, 369–370. doi: 10.1111/j.1467-9280.2007.01906.x

PubMed Abstract | Crossref Full Text | Google Scholar

Shah, R., Patel, N., Emin, M., Celik, Y., Jimenez, A., Gao, S., et al. (2023). Statins restore endothelial protection against complement activity in obstructive sleep apnea: a randomized clinical trial. Ann. Am. Thorac. Soc. 20, 1029–1037. doi: 10.1513/AnnalsATS.202209-761OC

PubMed Abstract | Crossref Full Text | Google Scholar

Shaw, J. E., Punjabi, N. M., Naughton, M. T., Willes, L., Bergenstal, R. M., Cistulli, P. A., et al. (2016). The effect of treatment of obstructive sleep apnea on glycemic control in type 2 diabetes. Am. J. Respir. Crit. Care Med. 194, 486–492. doi: 10.1164/rccm.201511-2260OC

PubMed Abstract | Crossref Full Text | Google Scholar

Shirlaw, T., Hanssen, K., Duce, B., and Hukins, C. A. (2017). Randomized crossover trial comparing autotitrating and continuous positive airway pressure in subjects with symptoms of aerophagia: effects on compliance and subjective symptoms. J. Clin. Sleep Med. 13, 881–888. doi: 10.5664/jcsm.6658

PubMed Abstract | Crossref Full Text | Google Scholar

Skatrud, J. B., and Dempsey, J. A. (1983). Interaction of sleep state and chemical stimuli in sustaining rhythmic ventilation. J. Appl. Physiol. Respir. Environ. Exerc. Physiol. 55, 813–822. doi: 10.1152/jappl.1983.55.3.813

PubMed Abstract | Crossref Full Text | Google Scholar

Smith, I., and Lasserson, T. J. (2009). Pressure modification for improving usage of continuous positive airway pressure machines in adults with obstructive sleep apnoea. Cochrane Database Syst. Rev. 2009:CD003531. doi: 10.1002/14651858.CD003531.pub3

PubMed Abstract | Crossref Full Text | Google Scholar

Stadler, D. L., McEvoy, R. D., Bradley, J., Paul, D., and Catcheside, P. G. (2010). Changes in lung volume and diaphragm muscle activity at sleep onset in obese obstructive sleep apnea patients vs. healthy-weight controls. J. Appl. Physiol. 109, 1027–1036. doi: 10.1152/japplphysiol.01397.2009

PubMed Abstract | Crossref Full Text | Google Scholar

Strumpf, D. A., Harrop, P., Dobbin, J., and Millman, R. P. (1989). Massive epistaxis from nasal CPAP therapy. Chest 95:1141. doi: 10.1378/chest.95.5.1141

PubMed Abstract | Crossref Full Text | Google Scholar

Sullivan, C. E., Issa, F. G., Berthon-Jones, M., and Eves, L. (1981). Reversal of obstructive sleep apnoea by continuous positive airway pressure applied through the nares. Lancet 1, 862–865. doi: 10.1016/s0140-6736(81)92140-1

PubMed Abstract | Crossref Full Text | Google Scholar

Tamisier, R., Pepin, J. L., Wuyam, B., Deschaux, C., and Levy, P. (2004). Expiratory changes in pressure: flow ratio during sleep in patients with sleep-disordered breathing. Sleep 27, 240–248. doi: 10.1093/sleep/27.2.240

PubMed Abstract | Crossref Full Text | Google Scholar

Ulander, M., Johansson, M. S., Ewaldh, A. E., Svanborg, E., and Brostrom, A. S. i. d. e. (2014). effects to continuous positive airway pressure treatment for obstructive sleep apnoea: changes over time and association to adherence. Sleep Breath. 18, 799–807. doi: 10.1007/s11325-014-0945-5

PubMed Abstract | Crossref Full Text | Google Scholar

Van de Graaff, W. B. (1988). Thoracic influence on upper airway patency. J. Appl. Physiol. 65, 2124–2131. doi: 10.1152/jappl.1988.65.5.2124

PubMed Abstract | Crossref Full Text | Google Scholar

Van Ryswyk, E., Anderson, C. S., Antic, N. A., Barbe, F., Bittencourt, L., Freed, R., et al. (2019). Predictors of long-term adherence to continuous positive airway pressure in patients with obstructive sleep apnea and cardiovascular disease. Sleep 42:zsz152. doi: 10.1093/sleep/zsz152

PubMed Abstract | Crossref Full Text | Google Scholar

Vitacca, M., Ambrosino, N., Clini, E., Porta, R., Rampulla, C., Lanini, B., et al. (2001). Physiological response to pressure support ventilation delivered before and after extubation in patients not capable of totally spontaneous autonomous breathing. Am. J. Respir. Crit. Care Med. 164, 638–641. doi: 10.1164/ajrccm.164.4.2010046

PubMed Abstract | Crossref Full Text | Google Scholar

Vroegop, A. V., Smithuis, J. W., Benoist, L. B., Vanderveken, O. M., and Vries, N. (2015). CPAP washout prior to reevaluation polysomnography: a sleep surgeon's perspective. Sleep Breath. 19, 433–439. doi: 10.1007/s11325-014-1086-6

PubMed Abstract | Crossref Full Text | Google Scholar

Weaver, T. E., and Grunstein, R. R. (2008). Adherence to continuous positive airway pressure therapy: the challenge to effective treatment. Proc. Am. Thorac. Soc. 5, 173–178. doi: 10.1513/pats.200708-119MG

PubMed Abstract | Crossref Full Text | Google Scholar

Weaver, T. E., Maislin, G., Dinges, D. F., Bloxham, T., George, C. F., Greenberg, H., et al. (2007). Relationship between hours of CPAP use and achieving normal levels of sleepiness and daily functioning. Sleep 30, 711–719. doi: 10.1093/sleep/30.6.711

PubMed Abstract | Crossref Full Text | Google Scholar

White, D. P., Messineo, L., Thompson, E., Hughes, B., Lannom, W. D., Hete, B., et al. (2024). Kairos positive airway pressure (KPAP) equals continuous PAP in effectiveness, and offers superior comfort for obstructive sleep apnea treatment. Sleep Med. 124, 268–275. doi: 10.1016/j.sleep.2024.09.028

PubMed Abstract | Crossref Full Text | Google Scholar

Woods, S. W., Charney, D. S., Goodman, W. K., and Heninger, G. R. (1988). Carbon dioxide-induced anxiety. Behavioral, physiologic, and biochemical effects of carbon dioxide in patients with panic disorders and healthy subjects. Arch. Gen. Psychiatry. 45, 43–52. doi: 10.1001/archpsyc.1988.01800250051007

PubMed Abstract | Crossref Full Text | Google Scholar

Zeineddine, S., and Badr, M. S. (2021). Treatment-emergent central apnea: physiologic mechanisms informing clinical practice. Chest 159, 2449–2457. doi: 10.1016/j.chest.2021.01.036

PubMed Abstract | Crossref Full Text | Google Scholar

Zhu, K., Aouf, S., Roisman, G., and Escourrou, P. (2016). Pressure-relief features of fixed and autotitrating continuous positive airway pressure may impair their efficacy: evaluation with a respiratory bench model. J. Clin. Sleep Med. 12, 385–392. doi: 10.5664/jcsm.5590

PubMed Abstract | Crossref Full Text | Google Scholar

Zinchuk, A. V., Chu, J. H., Liang, J., Celik, Y., Beeck, S., Redeker, N. S., et al. (2021). Physiological traits and adherence to sleep apnea therapy in individuals with coronary artery disease. Am. J. Respir. Crit. Care Med. 204, 703–712. doi: 10.1164/rccm.202101-0055OC

PubMed Abstract | Crossref Full Text | Google Scholar

Zinchuk, A. V., Redeker, N. S., Chu, J. H., Liang, J., Stepnowsky, C., Brandt, C. A., et al. (2020). Physiological traits and adherence to obstructive sleep apnea treatment in patients with stroke. Am. J. Respir. Crit. Care Med. 201, 1568–1572. doi: 10.1164/rccm.201911-2203LE

PubMed Abstract | Crossref Full Text | Google Scholar

Keywords: inspiratory pressure, positive airway pressure, KairosPAP™ (KPAP™), V.-Com®, PAP algorithms, pressure support

Citation: Messineo L, White DP and Noah WH (2024) Positive airway pressure delivery: overcoming old hurdles, exploring new frontiers. Front. Sleep 3:1522635. doi: 10.3389/frsle.2024.1522635

Received: 04 November 2024; Accepted: 28 November 2024;
Published: 20 December 2024.

Edited by:

Ding Zou, University of Gothenburg, Sweden

Reviewed by:

Dries Testelmans, University Hospitals Leuven, Belgium
Karin Johnson, Baystate Medical Center, United States

Copyright © 2024 Messineo, White and Noah. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Ludovico Messineo, bHVkb3ZpY28ubWVzc2luZW8mI3gwMDA0MDt5YWhvby5pdA==

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.