AUTHOR=Luy Edward , Smith James , Grundke Iain , Sonnichsen Colin , Furlong Arnold , Sieben Vincent TITLE=Two chemistries on a single lab-on-chip: Nitrate and orthophosphate sensing underwater with inlaid microfluidics JOURNAL=Frontiers in Sensors VOLUME=3 YEAR=2022 URL=https://www.frontiersin.org/journals/sensors/articles/10.3389/fsens.2022.1080020 DOI=10.3389/fsens.2022.1080020 ISSN=2673-5067 ABSTRACT=

Autonomous in situ sensors are required to monitor high-frequency nutrient fluctuations in marine environments on a mass-scale. We present a submersible, dual-chemistry sensor that performs multiple colourimetric assays simultaneously on a fluid sample for multi-parameter in situ analysis. Based on a highly configurable architecture that has been successfully deployed for several multi-month periods, the sensor utilizes 10 solenoid valves, 4 syringes, 3 stepper motors, 2 LEDs, 4 photodiodes, and “inlaid” microfluidics to permit optical measurements of microliter fluid volumes. Fluid pathways are machined into a modular two-layer microfluidic lab-on-chip (LOC) fabricated from poly (methyl methacrylate) (PMMA) with two parallel inlaid optical cells of 10.4 mm and 25.4 mm path lengths (1.7 µl and 4 μl, respectively). Different LOC designs can be used to implement a wide variety of colorimetric assays. We demonstrate application of our dual-chemistry sensor towards simultaneous measurement of nitrate and dissolved orthophosphate: two nutrients fundamental to primary production. The performance of the dual-species nitrate and phosphate “NP Sensor” is characterized first in a controlled laboratory environment. Combined nutrient standards containing nitrate and phosphate concentrations ranging from 2.5 µM–100 µM NO3 and 0.25 µM–10 µM PO43 were analyzed, reporting detection limits of 97 nM NO3 and 15 nM PO43. Calibrations were repeated under 3 fixed temperature conditions, T = 5°C, 10°C, 15°C, to determine the temperature-dependent sensitivity relations for both species needed to calculate concentrations during field deployments. Finally, an 8-day field deployment in Fish Hatchery Park, NS, Canada followed, acquiring a total of 592 nitrate and dissolved orthophosphate measurements. An on-board combined nutrient standard was measured periodically to assess the in situ accuracy of the sensor, with an average relative uncertainty of 15% across the deployment. Measured nitrate and dissolved orthophosphate levels in the river reached as high as 10 µM and 3.6 µM, respectively. Fast Fourier transform analysis suggests a strong out-of-phase relationship between measured phosphate and water level, with a shared frequency peak in both data agreeing within a 3.2% difference. This trend is due to conventional mixing at the river mouth to neighboring Bedford Basin. A spike in the measured nitrate to phosphate (N:P) ratio was also observed, synchronized to a precipitation event and indicative of runoff. The novel sensor will enable high-frequency dual-nutrient monitoring in many aquatic environments.