Skip to main content

ORIGINAL RESEARCH article

Front. Robot. AI
Sec. Robot Design
Volume 11 - 2024 | doi: 10.3389/frobt.2024.1367474
This article is part of the Research Topic Medical Robot Design: From Clinical Need to Validation View all 3 articles

Unveiling Human Biomechanics: Insights into Lower Limb Responses to Disturbances that Can Trigger a Fall

Provisionally accepted
  • Center for MicroElectroMechanical Systems, University of Minho, Guimarães, Portugal

The final, formatted version of the article will be published soon.

    Slip-related falls are a significant concern, particularly for vulnerable populations such as the elderly and individuals with gait disorders, necessitating effective preventive measures. This manuscript presents a biomechanical study of how the lower limbs react to perturbations that can trigger a slip-like fall, with the ultimate goal of identifying target specifications for developing a wearable robotic system for slip-like fall prevention. Our analysis provides a comprehensive understanding of the natural human biomechanical response to slip perturbations in both slipping and trailing legs, by innovatively collecting parameters from both the sagittal and frontal plane since both play pivotal roles in maintaining stability and preventing falls and thus provide new insights to fall prevention. We investigated various external factors, including gait speed, surface inclination, slipping foot, and perturbation intensity, while collecting diverse data sets encompassing kinematic, spatiotemporal parameters, electromyographic data, as well as torque, range of motion, rotations per minute, detection, and actuation times. The biomechanical response to slip-like perturbations by the hips, knees, and ankles of the slipping leg was characterized by extension, flexion, and plantarflexion moments, respectively. In the trailing leg, responses included hip flexion, knee extension, and ankle plantarflexion. Additionally, these responses were influenced by gait speed, surface inclination, and perturbation intensity. Our study identified target range of motion parameters of 85.19°, 106.34°, and 95.23° for the hips, knees, and ankles, respectively. Furthermore, rotations per minute values ranged from 17.85 to 51.10 for the hip, 21.73 to 63.80 for the knee, and 17.52 to 57.14 for the ankle joints. Finally, flexion/extension torque values were estimated as -3.05 to 3.22 Nm/kg for the hip, -1.70 to 2.34 Nm/kg for the knee, and -2.21 to 0.90 Nm/kg for the ankle joints. This study contributes valuable insights into the biomechanical aspects of slip-like fall prevention and informs the development of wearable robotic systems to enhance safety in vulnerable populations.

    Keywords: biomechanical response, Slip-like perturbation, Fall prevention, Target specification, Wearable robotic device

    Received: 08 Jan 2024; Accepted: 27 Aug 2024.

    Copyright: © 2024 Ferrete Ribeiro, Armada, Nunes, Carvalho and Santos. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

    * Correspondence: Nuno Ferrete Ribeiro, Center for MicroElectroMechanical Systems, University of Minho, Guimarães, 4800-058, Portugal

    Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.