Ingestion of methanol can result in severe irreversible morbidity, and death. Simple and easy methods to detect methanol and other hazardous additives prior to consumption can prevent fatalities. This form of harm reduction is analogous to the widely practiced “pill testing” of recreational drugs in various countries. We aimed to evaluate the performance of two qualitative and quantitative kits to simultaneously identify the presence of methanol and formaldehyde in alcoholic beverages, and compare this to the standard gas chromatographic (GC) method.
Two-hundred samples of Indian and Iranian alcoholic drinks were examined by two new qualitative and quantitative chemical kits designed based on a modified chromotropic acid (CA) method, as well as a gold standard GC method.
Methanol levels were similar when evaluated by GC and quantitative method (
Methanol and formaldehyde can be easily detected using these simple CA chemical kits. Qualitative positive results may indicate the risk of poisoning if the beverage is consumed. CA kits can be used in community setting by public health units and community organizations to monitor for methanol contamination and inform a public health response to reduce methanol-related harms to the public.