AUTHOR=Brumer Nadav , Elkins Elizabeth , Hillyer Jake , Hazlewood Chantel , Parbery-Clark Alexandra TITLE=Relationships Between Health-Related Quality of Life and Speech Perception in Bimodal and Bilateral Cochlear Implant Users JOURNAL=Frontiers in Psychology VOLUME=13 YEAR=2022 URL=https://www.frontiersin.org/journals/psychology/articles/10.3389/fpsyg.2022.859722 DOI=10.3389/fpsyg.2022.859722 ISSN=1664-1078 ABSTRACT=Purpose

Previous studies examining the relationship between health-related quality of life (HRQoL) and speech perception ability in cochlear implant (CI) users have yielded variable results, due to a range of factors, such as a variety of different HRQoL questionnaires and CI speech testing materials in addition to CI configuration. In order to decrease inherent variability and better understand the relationship between these measures in CI users, we administered a commonly used clinical CI speech testing battery as well as two popular HRQoL questionnaires in bimodal and bilateral CI users.

Methods

The Glasgow Benefit Inventory (GBI), a modified five-factor version of the GBI (GBI-5F), and the Nijmegen Cochlear Implant Questionnaire (NCIQ) were administered to 25 CI users (17 bimodal and 8 bilateral). Speech perception abilities were measured with the AzBio sentence test in several conditions (e.g., quiet and noise, binaural, and first-ear CI only).

Results

Higher performance scores on the GBI general subscore were related to greater binaural speech perception ability in noise. There were no other relationships between the GBI or NCIQ and speech perception ability under any condition. Scores on many of the GBI-5F factors were substantially skewed and asymmetrical; therefore, correlational analyses could not be applied. Across all participants, binaural speech perception scores were greater than first-ear CI only scores.

Conclusion

The GBI general subscore was related to binaural speech perception, which is considered the everyday listening condition of bimodal and bilateral CI users, in noise; while the more CI-specific NCIQ did not relate to speech perception ability in any listening condition. Future research exploring the relationships between the GBI, GBI-5F, and NCIQ considering bimodal and bilateral CI configurations separately is warranted.