Skip to main content

REVIEW article

Front. Plant Sci., 31 July 2023
Sec. Plant Biophysics and Modeling
This article is part of the Research Topic Plant Sensing and Computing - PlantComp 2022 View all 8 articles

Plant impedance spectroscopy: a review of modeling approaches and applications

  • Knowledge-Based Systems (KERMIT), Department of Data Analysis and Mathematical Modelling, Faculty of Bioscience Engineering, Ghent University, Ghent, Belgium

Electrochemical impedance spectroscopy has emerged over the past decade as an efficient, non-destructive method to investigate various (eco-)physiological and morphological properties of plants. This work reviews the state-of-the-art of impedance spectra modeling for plant applications. In addition to covering the traditional, widely-used representations of electrochemical impedance spectra, we also consider the more recent machine-learning-based approaches.

1 Introduction

Electrochemical impedance spectroscopy (EIS) is a popular method to characterize the electrical properties of (bio-)electrochemical systems. Applying an alternating voltage input1 V(f) to a plant tissue sample gives rise to the flow of an electric current I(f) through the cell walls, between cells, and in the plant fluids. The polarization processes caused by resistive and capacitive elements in the plant tissue impede the flow of this electric current, resulting in a phase shift between the current and voltage phasors. This phenomenon is the electrochemical impedance of the sample and can be measured at multiple frequencies f using an analyzer. The impedance Z(ω), where ω=2πf, is a complex-valued quantity that relates to the current and voltage as

Z(ω)=V(ω)I(ω)=|Z(ω)|(cos(ϕ(ω))+jsin(ϕ(ω))) ,(1)

where |Z(ω)| is the magnitude of the impedance and ϕ(ω) is the phase angle between the current and the voltage. There is ample evidence that the measurement of Z(ω) over a range of frequencies (giving rise to an impedance spectrum) holds promise in ascertaining a range of plant physiological properties (Jócsák et al., 2019), including various types of plant stress (Lichtenthaler, 1998). As ω=2πf, a function in terms of ω is also a function of f. In the remainder of this work, we express the impedance as a function of f to make the dependence on the input frequency in Hz explicit. The non-invasive nature of impedance spectroscopy measurements allows for the influence of an (a)biotic stressor to be analyzed without being confounded by damage caused by the measurement technique.

Phospholipid bilayer membranes in plant cells act as capacitors, forming an electrical double layer at their interfaces when exposed to an electrical field. Charge-carrying molecules in the symplast (i.e., the intracellular matrix) and apoplast (i.e., the extracellular matrix) electrolytes give rise to electrical resistances. When an alternating voltage input pulse is applied, the electrochemical components in the plant cells undergo polarization and subsequent dielectric relaxation. The nature and intensity of this polarization depend on the properties of the measured tissue and the interrogated frequency. At low frequencies, the capacitive membranes obstruct current flow into the cells, and the resulting current only flows through the extracellular matrix. At higher frequencies, the current can penetrate the cells, allowing for the interrogation of the intracellular impedance caused by polarization processes in the cytoplasm, which contains charged molecules and capacitive membrane structures. Several published works provide visualizations of this phenomenon (Azzarello et al., 2006; Ehosioke et al., 2020; Liu et al., 2021a; Cheng et al., 2022). Changes in plant physiology are reflected in the different polarization processes and their corresponding relaxation. All this information is contained within an adequately measured electrochemical impedance spectrum. The challenge addressed by plant EIS modeling is to extract this information from the impedance spectra to attain a valuable characterization of the considered plant system.

Two types of plot are typically used to visualize impedance spectra: Nyquist plots, which display the real values of the impedance measurements as a function of their imaginary components, and Bode plots, which display the magnitude and the phase of the impedance as a function of the measured frequencies (Orazem and Tribollet, 2008; Barsoukov and Macdonald, 2018; Wang et al., 2021). Cole–Cole plots are also used to represent impedance spectra and originate from a 1941 publication by the Cole brothers (Cole and Cole, 1941). They display a material’s complex dielectric constant (related to its impedance) over the measured frequencies. Its real and imaginary parts are represented on the x- and y-axis, respectively. Cole–Cole plots are often confused with Nyquist plots, as they are both Argand diagrams. One drawback of Nyquist and Cole–Cole plots is that they do not provide explicit frequency information. This is sometimes mitigated by adding an indication of the frequency to the observations in the plot. This is done by placing the frequency values next to the observations in the plots. Alternatively, a 3D representation is used, where the frequencies are included as an additional axis (Macdonald et al., 1981; Arteaga et al., 2021).

Given the enormous waste of agricultural produce in the destructive assessment of in-field and post-harvest product quality due to the requirement of a sufficiently large sample size, there is an ever-growing need for clean and effective non-invasive product evaluation methods (Vanoli and Buccheri, 2012; Lakshmi et al., 2017). A growing body of research promotes the use of EIS-based product assessment in this regard (El Khaled et al., 2017; Ibba et al., 2020). While there is expensive commercial multi-modal equipment for EIS, effective custom setups within a price range of a few hundred USD have been used successfully in agricultural applications (Basak et al., 2020a). In parallel with developments in sensors and equipment, the correct and in-depth modeling of plant impedance spectra will allow for the unravelling of the unexplored potential of EIS further.

A panoply of plant phenotyping methods has been developed to investigate various properties related to the agricultural yield and health status of crops. Each of these methods has benefits and drawbacks. An often-reported comparative advantage of EIS in plant characterization studies is that it is less sensitive to environmental influences (Hussain et al., 2021). Table 1 presents a non-exhaustive overview of plant phenotyping methods for which EIS holds promise as a complementary or competitive analysis method. This table does not include Electrical Impedance Tomography (EIT), Spectral Induced Polarization (SIP), or single-frequency impedance measurements, which we consider to be specific variants of EIS rather than complementary or competitive methods. We refer to other works for more in-depth discussions on non-destructive plant phenotyping methods (Zerbini, 2006; Rahaman et al., 2015; Ali et al., 2017; Lakshmi et al., 2017; Ali et al., 2019).

TABLE 1
www.frontiersin.org

Table 1 Plant characterization methods for which EIS holds promise as a competitive or complementary method.

An overall impedance spectrum is obtained when conducting impedance measurements over a range of frequencies. Yet, apart from the electrochemical response of the system under investigation, it can often also include other factors that affect the impedance, such as artefacts and influences due to the experimental equipment. When conducting EIS measurements, the experimental setup must be carefully considered, as it will significantly impact the appropriate choice and performance of the subsequent modeling and analysis. Important considerations include the electrode configuration, the applied frequency range and resolution, the use of minimally interfering connecting cables, and the environmental conditions. Appropriate measures should be taken to address the challenge of decoupling the measurement equipment from the system under test, as well as to ensure that the linearity, stability, and causality requirements for EIS measurements are satisfied. We refer to several excellent recent reviews for in-depth discussions covering the above-mentioned experimental considerations (El Khaled et al., 2017; Prasad and Roy, 2020; Wang et al., 2022; Lazanas and Prodromidis, 2023). In this review, we closely examine the contemporary modeling approaches for EIS in plant applications and aim to provide direction for the recent emergence of machine learning applications in the field.

The paper’s scope covers modeling approaches and data analysis techniques for plant impedance spectroscopy and their application areas. The remainder of this paper is organized as follows. Section 2 provides an overview of plant EIS applications, organized according to the measured organ of the plant. An extensive survey of equivalent electrical circuit modeling approaches for plant characterization and their interpretation is given in Section 3. Section 4 constitutes a thorough review of statistical and predictive modeling methods used for the impedimetric analysis of plants using EIS. Section 5 contains a critical discussion of the preceding sections. The conclusions of this work and suggested future directions of the field finalize this paper in Section 6.

2 Overview of plant EIS applications

In precision agriculture, the knowledge of external conditions (e.g., soil and air properties) is insufficient to make informed fertilizer and irrigation management decisions (Nowak, 2021). Only interrogation of the plant itself can provide an adequate indication of its physiological state. This statement is the basis for the Speaking Plant Approach (SPA) proposed by Udnik ten Cate in the late 70s (Udink ten Cate et al., 1978). The use of polyvalent EIS-based sensors holds promise for use in precision farming. Here they can enable fertilizer application to specific areas in the farm and inform various farming management decisions when combined with a range of other collected data in a “smart farm” using the Internet of Things (IoT) (Elijah et al., 2018). As a robust, non-destructive, and inexpensive method, EIS provides the means to conduct analyses that conform with the SPA. The applications of EIS to plants are numerous. EIS measurements are typically conducted at the leaves, fruits, stems or roots, depending on the considered application. To our knowledge, no studies report measurements of a plant’s flowers. A general overview of some plant properties and where they can be indirectly measured through EIS is displayed in Figure 1. Aside from direct plant measurements, several works explored soil EIS measurements for agricultural applications. These include soil moisture content and indirect plant biomass determination (Wang et al., 2019).

FIGURE 1
www.frontiersin.org

Figure 1 An overview of a number of EIS applications organized according to the organ of the plant at which the electrodes are typically placed for interrogation.

2.1 Roots

Roots are the plant organs responsible for interacting with the soil to secure water, minerals, (micro)nutrients, and, for some species, symbiotic nitrogen-fixing bacteria. A comprehensive analysis and understanding of roots are essential to investigate the complex interactions of plants with the soil and the climate. Electrical methods hold promise in overcoming the difficulties in accessing root properties (Ehosioke et al., 2020). An accurate and thorough characterization of plant root systems allows for the establishment of optimal use of water and fertilizer, assuring maximal crop quality and yield. Particularly in light of current global environmental issues such as food waste, inadequate fertilization and irrigation management, there is a need for in-depth, fast, easy, non-destructive, and in situ methods to evaluate the morphological and physiological properties of plant roots. The discovery that there is a linear relationship between the capacitance of a plant’s roots and their size in the last century prompted the ever-growing interest in investigating plant roots by measuring their electrochemical properties. Ozier–Lafontaine and Bajazet (2005) established strong correlations between the capacitance of root tissue and the (wet and dry) weight of the root system. The EIS method has demonstrated its potential to indirectly assess and monitor the root biomass, morphological indices (Cao et al., 2011), and environmental stressors, including cadmium pollution, alkali stress, drought, freeze–thaw damage (Repo et al., 2016), cold acclimation (e.g., frost hardening), osmotic stress, root hypoxia (Vozary et al., 2012) (e.g., caused by flooding; Jócsák et al., 2010), root mycorrhizal colonization (Repo et al., 2014), and weed competition. Liu et al. (2021a) recently conducted an in-depth review of progress and developments in applying EIS to plant roots.

2.2 Stem

The stem of a plant grants it structural strength while providing a means for the unidirectional upwards transport of water to the leaves and fruits and the bidirectional transport of assimilates, other nutrients, and signaling molecules through the phloem. EIS measurements have been conducted at the stems of plants to investigate a range of phenotypical properties. Direct plant monitoring is one of the strategies in precision agriculture to improve crop yield, working towards food security for the increasing global population. Bar-On et al. (2021) recently developed an EIS method for in-vivo, in situ, and non-destructive monitoring of a plant’s physiological status. It is based on a four-electrode setup attached to the stem of a Nicotiana tabacum plant used as a dicot plant model.

Tomkiewicz and Piskier (2012) proposed a nutrition index, calculated using the impedance magnitude values measures at the stem of tomato plants over a frequency range of 1.5 kHz to 16 kHz. This constitutes an initial step towards site-specific fertilizer management in greenhouses. Borges et al. (2012) provided initial evidence for the potential of EIS for early detection of plant diseases. Differences in impedance spectra (measured at the stem) were observed for young pine plants infected with the nematode Bursaphelenchus xylophilus (Borges et al., 2012). The rooting potential of shoot cuttings was investigated by Mancuso (1999) through double-DCE equivalent electrical circuit models. Recently, Astashev et al. (2022) also developed a sensor and model to conduct in situ EIS measurements evaluating the physiological condition of trees. Branch length, tree health, and effects of drying and grafting were all impedimetrically evaluated. Aouane et al. (2021) evaluated EIS as a method to monitor evapotranspiration on a celery stalk. They found that the extracellular resistance from a Cole EEC model can describe different stages of water loss and nutrient depletion.

2.3 Leaves

Leaves assimilate the plant’s carbohydrates through photosynthesis. They also regulate the flow of water during evapotranspiration. The water potential of plants is an essential parameter to model a range of physiological processes (De Swaef et al., 2022). The non-invasive attachment of electrodes to plant leaves allows for real-time in-vivo monitoring of several important plant properties using EIS. EIS has been proposed to evaluate a plant’s water status and potential. Basak et al. (2020a) modelled the relative water content (RWC) of canola, corn, wheat, and soybean leaves using multivariate linear regression with impedance magnitude features at different frequencies that were selected using backward elimination. They conducted a similar analysis for the leaf nitrogen content of these crops (Basak et al., 2020b). To that end, they used a portable and relatively cheap device. Xing et al. (2021) demonstrated a strong correlation between the impedance of leaves and their water status through the cell elasticity, which was measured by leaf clamping with different gripping forces. The authors used polyethylene glycol (PEG) to induce different osmotic stress levels in Orychophragmus violaceus in their experiments. Ali Solangi et al. (2021) linked plant capacitance to the vacuole and cell volume in their study of mangrove plants’ salt storage capacity. Recently, Nouaze et al. (2022) exhibited the potential of EIS for real-time in-vivo physiological monitoring of lettuce, while Sugiyama and Okajima (2022) demonstrated that the solar illumination of plants is reflected in their impedance spectra.

2.4 Fruits

The fruits of a plant contain the seeds required for reproduction. This is of particular commercial interest due to its use as a food product and other commodities. Applications of EIS measurements on fruits include fruit maturity and firmness (Ivanovski et al., 2020) and the composition and cell vitality of fruits (Caravia et al., 2015). Caravia et al. (2015) found that the impedance of Shiraz grapes follows the accumulation of total suspended solids during cell death in berries at a late ripening stage. They also conducted experiments to electrochemically evaluate changes in veraison grapes to 110 days after anthesis and assessed the effects of freezing and thawing on grape impedance spectra. EIS has also been applied to evaluate the effects of processing agricultural products (e.g., drying and freeze–thawing). The freezing of agricultural products causes the formation of ice crystals in the plant tissues. These ice crystals cause cell membrane rupturing, resulting in the loss of the latter’s capacitive properties. The impedance is further decreased upon thawing due to leakage of the intercellular matrix to the extracellular space. As the intracellular medium is less resistive than the extracellular matrix (Lee and Watanabe, 2022), this causes a substantial decrease in the latter after plasmolysis and the resulting electrolyte leakage. Wu et al. (2008) did such an evaluation on eggplant pulp. Applying EIS for fruit status appraisal will allow for further development and automation in horticulture (e.g., automatic picking of ripe fruit with robotic arms; Park et al., 2022).

Watanabe et al. recently proposed a feature extracted from the Nyquist plot to assess damage in biological tissues during the processing of agricultural products (Watanabe et al., 2018):

LTO=|Ztop|=(ZtopRe)2+(ZtopIm)2 .(2)

This feature is the length of the impedance vector Ztop where the circular arc in the Nyquist plot reaches its zenith and is called the LTO (Length Top Origin). The LTO has been used to impedimetrically assess treatments of mechanical bruising, hydrostatic pressure, and freeze damage of Japanese pears (Watanabe et al., 2018; Lee et al., 2019; Lee and Watanabe, 2022). The authors reported a correlation between the LTO and the electrical resistance value of the extracellular matrix. The fruit tissues analyzed using the LTO only showed a single impedance arc in the Nyquist plot. While a correlation was found with the resistance of the extracellular matrix, the LTO remains somewhat arbitrary. More principled indicators, such as the cell disintegration index presented and derived in Angersbach et al. (1999), should be preferred. This index indicates the degree of cell permeabilization (i.e., disintegration) based on changes in the conductivity behavior of the sample. The cell disintegration index assumes an equivalent electrical circuit model. Such models are discussed in the next section.

3 Plant equivalent circuit modeling

Equivalent electrical circuits (EECs) are one of the earliest-developed and most successful tools for analyzing plant EIS measurements. A myriad of equivalent electrical circuits for analyzing biological tissues have been proposed since the second middle of the last century. They are currently still the most widely used models in EIS analysis, albeit they are subject to some criticism. One such criticism is that there is degeneracy in EECs: multiple EEC configurations are capable of modeling a given set of EIS measurements. Several examples of such “degenerate equivalent circuits” were compiled by Fletcher (1994). Apart from achieving a high-quality fit, care must be taken to use circuit models with a clear biophysical meaning without being more elaborate than they should be. An appropriate EEC can provide insights into a variety of plant physiological processes. Furthermore, when fit to the impedance measurements, the parameters of an EEC are effective at summarizing the information present, making them valuable features in statistical models and diagnostic tools. As such, the physiological state of a plant system can be monitored through the tracking of EEC parameters.

3.1 Plant equivalent circuit configurations

The three circuit components typically encountered in a plant EEC are resistors (R), capacitors (C), and constant phase elements (CPE). Their respective impedance expressions are given by:

ZR(f)=R(3)
ZC(f)=j·12πfC(4)
ZCPE(f)=1Q[cos(π2α)+jsin(π2α)](2πf)α=1Q(2πjf)α.(5)

Here, f is the frequency, R is the resistance, C is the capacitance, and Q and α[0,1] (dispersion or distribution coefficient, a measure of deviation from ideal capacitive behavior) are the two parameters associated with the CPE. CPEs get their name from their property of giving rise to impedance measurements whose phase angle is independent of the frequency but dependent on the parameter α. The Warburg element is a special case of a CPE, where α=0.5. It is commonly used for modeling diffusion processes in mass transfer. The impedance expressions in Eqs. (3)–(5) are used together with Kirchoff’s laws to obtain the impedance expressions of the EEC.

Table 2 displays the simple Voigt circuit and the single and double shell models (derivations of) that are applied in most plant EIS applications. Voigt circuits are often serially expanded to contain additional parallelly connected resistors and capacitors so as to model different parts of the considered plant organ. The substitution of capacitors with CPEs in practical applications is a trend in the field of electrochemical power sources that has recently also been picked up in plant applications. Equivalent electrical circuits containing CPEs are commonly called fractional-order circuit models (Freeborn, 2013), whereas EECs consisting of resistors and capacitors are integer-order circuit models. In the literature, these two categories of EECs are often called lumped and distributed models, respectively. The Voigt circuit is often fractionalized to model complex bioelectrochemical processes by substituting the capacitor with a CPE, forming the single dispersion Cole model. The single dispersion Cole model is often expanded in series with another parallelly connected resistor-CPE element, resulting in the double dispersion Cole model. The impedance expression of the Cole models is given by

TABLE 2
www.frontiersin.org

Table 2 The basic equivalent electrical circuit models (derivations and modifications of) which are commonly used in the modeling of plant EIS measurements.

ZColeN(f)=R+n=1NRn1+(2πjf)αRnQn(6)

where N is the number of resistor-CPE element elements included in the model. N=1 for the single dispersion Cole model and N=2 for the double dispersion Cole model. The Cole models are simple and often fit the measurements well due to their fractional elements. They have been applied in various plant EIS applications (Wu et al., 2008; Mousa et al., 2019; Aouane et al., 2021).

The ZARC element (Macdonald, 1992), also referred to as the Distributed Circuit Element (DCE), is an alternative element often used in EECs. Its impedance expression ZZARC(f) is similar to that of the resistor-CPE components discussed above, but is expressed in terms of time constants rather than capacitances:

ZZARC(f)=R01+(2πjfτ)α ,(7)

where τ is the mean time constant. Note that the resistor-CPE element in Eq. (6) and the ZARC element in Eq. (7) coincide when RnQ=τα. As such, an alternative formulation of the double (or higher order) Cole model is a resistor in series with two (or more) ZARC elements. Such models, where each ZARC element models a specific part of a plant’s organ, are often applied in plant EIS research. Some examples are the papers by Repo et al. (1994; 2002), Ozier–Lafontaine and Bajazet (2005), Vozary et al. (2007; Vozáry and Benko, 2010), and many more (Mancuso and Rinaldelli, 1996; Mancuso, 1999).

The single shell model (see Table 2) is a simple EEC of plant cells, considering the cell membrane’s capacitance and the extra- and intracellular resistance. Its impedance expression is given by

Zsingle shell(f)=RE(1+2πjfCMRI)1+2πjfCM(RE+RI) ,(8)

where RE is the extracellular resistance, CM is the capacitance of the cell membrane, and RI is the intracellular resistance.

There are two commonly applied modifications of the single shell model. The first one is the Hayden model, where an additional resistor is parallelly connected to the cell membrane capacitance CM (Hayden et al., 1969). As the Hayden model predates the single shell model, the latter is sometimes called the simplified Hayden model. The simplification of the Hayden model by the omission of the additional resistance is motivated by the observation that this resistance is usually much larger than the other two resistances, as shown by Cole (1968). The second modification of the single shell model is the replacement of CM by a constant phase element, which leads to improved fitting to real impedance measurements in practice. This modified single shell model has more recently been proposed by Ando et al. (2014) with the following impedance expression:

Zsingle shell CPE(f)=RE[1+(2πf)αQ{(2RI+RE)·cos(π2α)+(2πf)αQRI(RE+RI)}]{(2πf)αQ(RE+RI)}22(2πf)αQ(RE+RI)·cos(π2α)+1                                      j×(2πf)αQRE2·sin(π2α){(2πf)αQ(RE+RI)}22(2πf)αQ(RE+RI)·cos(π2α)+1(9)

A drawback of the use of CPEs in equivalent circuit models is that this hinders a convenient and straightforward interpretation. This issue is typically mitigated by converting the values of the CPE’s parameters to their corresponding apparent equivalent capacitance values using the following conversion:

CM,apparant=Q(2πfm)(α1) ,(10)

where fm is the frequency that minimizes the imaginary part of the impedance. The value of fm is calculated as

fm=(Q(RE+RI))α2π .(11)

Combining Eqs. (10) and (11), the apparent cell membrane capacitance is calculated as

CM,apparant=Q1α(RR+RI)1αα .(12)

Note that the underlying assumption of Eqs. (10) and (12) is that the frequency at which the imaginary part of the impedance is minimal remains the same after substitution of the CPE by CM,apparant. This fractional single shell model with the calculation of the apparent capacitance has been used in many works since it was introduced by Ando et al. (Imaizumi et al., 2015; Ando et al., 2016; Meiqing et al., 2016; Watanabe et al., 2017; Watanabe et al., 2018; Li et al., 2019). The double shell model was proposed by Zhang and Wilson (1991) in an effort to take the electrochemical behavior of the vacuole into account. The impedance expression of the double shell model is reported in Inaba et al. (1995) and Wu et al. (2008). Despite being established over 30 years ago, the double shell model is still commonly used to analyze plant systems at present (Nouaze et al., 2022). Juansah et al. (2012) elaborated the double shell model further to include other fruit constituents. The authors report improved modeling of Garut fruit ripening with their proposed EEC. A fractional-order variant of this EEC has also been proposed (Cabrera-López and Velasco-Medina, 2019). Other elaborations of the double shell model, taking organelle resistances into account, have been proposed (Zhang et al., 1990; Harker and Maindonald, 1994), as well as a fractional variant of the double shell model substituting the capacitors with CPEs (AboBakr et al., 2017).

A bespoke choice should be made for the circuit to be used for analyzing a given set of plant EIS measurements, taking both the biophysical interpretation and quality of fit into consideration. That being said AboBakr et al. (2017) conducted a comparative evaluation of a selection of integer and fractional order EECs (including some of those discussed above) on electrochemical impedance measurements of several fruits. The authors concluded that the fractional single and double Cole models resulted in the best fit for the considered examples.

Electrode polarization effects at the interface between the plant and the measurement equipment are known to interfere with biological EIS measurements at low frequencies (Kuang and Nelson, 1998). Besides adjustments to the measurement setup, these effects are sometimes dealt with at the modeling stage through a serial addition in the EEC. Some novel EEC models with such additions were recently proposed by Ibba et al. (2020) and Sugiyama and Okajima (2022). Ibba et al.’s EEC model in their apple and banana ripening study (Ibba et al., 2020) consists of a Warburg element, modeling the interface between the fruit surface and the electrode, serially connected to a simple Voigt circuit. Sugiyama and Okajima (2022) proposed a fractional model that consists of a simple Voigt circuit, modeling the electrode–leaf contact, and a serially coupled fractionalized Hayden model describing the plant tissues. In later work, the same authors (Okajima and Sugiyama, 2023) simplified the part describing the plant tissues to a fractional single shell model, while adding a Warburg element in the part describing the electrode–leaf interface.

3.2 Parameter identification for plant EECs

A comprehensive equivalent-circuit-based analysis of EIS measurements relies on the adequate identification of the circuit parameters. The earliest described circuit parameterization methods were based on graphical measurements of the Nyquist plots (Cole, 1940). At present, the most common parameter estimation method is Complex Non-Linear Least Squares (CNLS) fitting, where the squared error between the measured impedance measurements and the simulated impedance spectra using the EEC and its parameters is minimized (Macdonald and Garber, 1977), i.e.:

F(κ)=i=0N|ΔZi|2=i=0N(Zi,eReZi,mRe(κ))2+(Zi,eImZi,mIm(κ))2(13)

Here, ΔZi is the difference between the experimental measurement and the equivalent circuit model’s corresponding impedance value for the i-th measured frequency. Zi,eRe and Zi,eIm are the real and imaginary parts of the experimental measurements at the i-th frequency, and Zi,mRe(κ) and Zi,mIm(κ) are the corresponding impedance values simulated by the circuit model using the parameter vector κ. The optimal EEC parameters for the considered circuit are argminκF(κ). The Levenberg-Marquart algorithm (Marquardt, 1963) is commonly used to solve this optimization problem, although many alternative algorithms have been proposed for bioimpedance analysis (Yousri et al., 2019; Gadallah et al., 2022; Ghoneim et al., 2022). Most plant EIS studies use the above method for circuit parameter identification, typically through commercial or freely available software, such as LEVM/LEVMW (MacDonald, 2013), EIS Spectrum Analyzer (Bondarenko and Ragoisha, 2005), LabView (Kodosky, 2020), or ZView (Johnson, 2000). A drawback of this method is that carefully chosen initial values for the equivalent electrical circuit model must be provided to the algorithm to ensure proper convergence. This parameter initialization can be done using graphical estimates, as in Ozier-Lafontaine and Bajazet (2005). Some researchers have circumvented the need for a good initialization by using optimization procedures that are less likely to get stuck in a local optimum due to an inadequate initial guess, such as evolutionary algorithms. The CNLS objective function in Eq. (13) is ubiquitously used and usually yields adequate results. However, it has also been subject to due criticism. In particular, an appropriate weighting of the two terms by the variance of the measurements (if available) or by the magnitudes of the experimental or model impedances (which are assumed to be proportional to the measurement variance) has been reported to be more appropriate in some works (Zoltowski, 1984; Orazem et al., 1994; Van Haeverbeke et al., 2021). This is especially the case when the measurements differ by several orders of magnitude, where a simple unit weighing causes F(κ) to be dominated by the larger impedance measurements.

In agricultural applications of EIS, it is desirable to conduct quick and efficient EIS measurements with inexpensive and portable hardware. EEC parameter estimation on incomplete measurements reduces the computational and hardware burden for such real-time and in-field applications. Freeborn et al. (2013) applied a non-linear least squares fitting method to accurately extract the parameters of the Cole model from the electrical current-excited step responses without requiring direct impedance measurements. Maundy et al. (2015) showed that the same could be done using only the impedance magnitudes, which also decreases the computational burden. Recently, Vastarouchas et al. (2019) developed a method to extract the Cole model parameters using only two measurements. Note that these methods are developed specifically for the Cole models described in Section 3.1 and are not applicable for general circuit parameter identification.

4 Statistical and machine learning methods for plant EIS

Researchers routinely apply various statistical methods when analyzing plant EIS measurements. These methods are typically applied to EIS features such as equivalent circuit parameters or impedance values at specific frequencies. They include various kinds of correlation analysis (Tomkiewicz and Piskier, 2012; Imaizumi et al., 2015; Hamed et al., 2016), as well as the comparison of multiple treatments using Analysis of Variance (ANOVA) (Jamaludin et al., 2014; Roy et al., 2019) with a range of posthoc tests (Harker and Forbes, 1997; Vozáry et al., 2007; Imaizumi et al., 2015; Meiqing et al., 2017).

Machine learning is the sub-discipline of artificial intelligence that focuses on automatically detecting patterns in data. In unsupervised learning, there is no outcome variable to be predicted. Here, patterns are detected within the unlabeled input data. Two important applications of unsupervised learning are clustering and dimensionality reduction. While being originally a classical statistical method, Principal Component Analysis (PCA) is an unsupervised learning algorithm commonly used to analyze plant EIS measurements (Cavalieri and Bertemes-Filho, 2021), where it aids in visualizing the impedimetric behavior resulting from different treatments in a study (Conesa et al., 2016; Hamed et al., 2016; Meiqing et al., 2016; Serrano-Pallicer et al., 2018; Ibba et al., 2020; Aparisi et al., 2021). It is a dimensionality reduction method that reduces the number of features in such a way that the most important information is retained. Some authors have applied dimensionality reduction methods to pre-process impedance features before conducting a supervised learning analysis (Guo et al., 2015; Conesa et al., 2016; Yu et al., 2016; Islam et al., 2018; Ochandio Fernández et al., 2019; Li et al., 2022). Alternatively, various methods have been used to select the most useful features before the analysis (Repo et al., 2014; Meiqing et al., 2016; Liu and Guo, 2017; Khaled et al., 2022).

In supervised learning, the goal is to predict an outcome variable that is often impractical to measure directly using a list of input variables (features). Depending on the nature of the response variable, a distinction is made between (i) regression problems, for which a continuous output value is to be predicted, and (ii) classification problems, for which the output is constrained to a discrete set of classes. After training (calibration) of supervised machine learning models, their predictive performance can be evaluated. For this, an appropriate performance metric should be selected. The model accuracy is the most common performance metric for plant EIS classification problems, which is the proportion of correct predictions relative to the total number of predictions. For regression problems, some commonly reported performance metrics are the coefficient of determination (R2) and the root-mean-square error (RMSE). The coefficient of determination is calculated for a set of N observations and regression model outputs as

R2=1i=1N(YiYi^)2i=1N(YiY¯)2(14)

This can be interpreted as the proportion of the variance in the dependent variable observations Yi that the regression model outputs Yi^ can explain. Y¯ is the mean of the observations Yi. The RMSE is expressed in the same unit as the response variable and is calculated as

RMSE=i=1N(YiYi^)2N .(15)

Another important consideration is the generalization ability of the model. A model generalizes well if it has a good predictive performance on new observations not used during model calibration. Overly complex models will fit the training data well but do not necessarily generalize well. This phenomenon is called overfitting. An appropriate model evaluation or selection, considering the possibility of overfitting, requires training and testing of the model to take place using separate sets of observations. In K-fold cross-validation, the full dataset is split into K different parts. The model is then consecutively trained on the dataset, excluding each of these parts and concurrently evaluating the excluded parts. The final performance estimation is the average evaluated performance on the K subsets. Statistical tests are also used for model selection. An example is a sequential F-test which can be used to compare models of varying complexity and assess the significance of newly introduced model elements.

We searched the literature for machine learning applications in EIS applied to plants. Table 3 presents the research works retrieved. The vast majority of these applications predict fruit properties, such as ripeness or quality characteristics. Over half of these entries are studies published within the last 3 years, indicating that supervised machine learning methods are rapidly gaining interest in plant impedance spectroscopy. The most commonly used classification methods are Artificial Neural Networks (ANN) (Goodfellow et al., 2016) and Linear Discriminant Analysis (LDA) (Bishop and Nasrabadi, 2006). The most commonly used regression methods are Partial Least Squares (PLS) regression (Wold et al., 2001) and Multivariate Linear Regression (MLR) (Bishop and Nasrabadi, 2006). The number of measurements in the collected studies typically varies from tens to hundreds. Overall, high prediction performances are reported. The impedance values at specific frequencies were the most commonly used features to train the reported models. In several of these studies, the impedance spectrum was not completely measured, but only a few different frequencies were considered.

TABLE 3
www.frontiersin.org

Table 3 Supervised machine learning approaches in plant electrochemical impedance spectroscopy.

5 Discussion

Valid EIS measurements of electrochemical systems conform to stability, causal, and time-invariance standards (Van Haeverbeke et al., 2022). Good practice dictates that the validity of measurements is verified before further analysis. EIS data validation through the Kramers–Kronig relations (Kronig, 1926) is an important standard in other EIS application areas (e.g., battery science). These relations evaluate the feasibility of computing the real part of the EIS measurements from the imaginary part and vice versa, which is a theoretical prerequisite for stable electrochemical systems. This data validation is rarely done for plant or other biological applications. The partial measurement of the impedance spectra (e.g., only measuring the real or imaginary parts to reduce the computational burden) described in Section 3.2 rules out the possibility of an adequate validation using the Kramers–Kronig relations.

The EIS field generally suffers from a lack of publicly available data. A notable exception, in the field of animal tissues, is the database of body tissue measurements compiled by Gabriel and Gabriel (1996). The further development of novel methods to analyze impedance spectroscopy measurements for plant applications would greatly benefit from publishing such collected data in well-maintained public databases accessible to other researchers. This could be done in a fashion similar to the MassIVE public database for mass-spectrometry measurements (Choi et al., 2020) or the many databases available for the bio-informatics community, such as Uniprot (Apweiler et al., 2004) and Genbank (Benson et al., 2012), to name a few.

Equivalent electrical circuits are still the standard tools for EIS analysis. Commonly applied EEC models in recent years are the double shell model and some fractionalized models such as the modified single shell model, the Cole model and distributed circuit element models with ZARC elements. The original integer-order Hayden and single-shell models are no longer commonly used. In some cases, arbitrarily complex EEC configurations are proposed in order to achieve an adequate fit to the plant EIS measurements (Islam et al., 2019). This results in the loss of the biophysical interpretation of the models, with a loss of the advantage of using EEC models over other non-linear models. Equation (10) is the widely applied mathematical formula proposed by Hsu and Mansfield (2001) for estimating the effective capacitance from CPE parameters in the fractional single shell model. Hirschorn et al. (2010) conducted a comparative evaluation of this formula and an alternative formula formerly proposed by Brug et al. (1984). A biological material was included in this study (human skin), where the formula by Brug et al. turned out to yield more satisfactory results. These results advocate further study on the most appropriate effective capacitance estimation procedure for plant systems.

A recent development in bio-impedance spectroscopy analysis is the use of the Distribution of Relaxation Times (DRT), which does not require the selection of a specific EEC model. Its strengths include the increased resolution in distinguishing different polarization processes and its general applicability. This analysis method has proven to be very effective in characterizing electrochemical power sources (Weiß et al., 2017). The initial development of a distribution of relaxation times analysis dates back to the beginning of the 19th century in work by von Schweidler (1907). The theory and methods were then further developed by the Cole brothers (Cole and Cole, 1941), among others. Schwan considered the theoretical description of a DRT for the analysis of biological tissues later in the last century (Schwan, 1957; Foster and Schwan, 1989). The improvement of EIS measurement technology and the development of adequate DRT deconvolution methods in the last decade have permitted its practical use. Recently, some promising evaluations of this method have been done for biological applications, such as the analysis of microbial fuel cells (Wang et al., 2022), animal tissues (Shi and Kolb, 2020), and cells in suspension (Ramírez-Chavarría et al., 2020). While this method has not yet been evaluated for plant EIS, recent developments in other fields suggest it could potentially become a valuable plant characterization method and provide informative features for machine learning models.

Due to the high dimensionality of EIS measurements and the typically limited (i.e., up to a few hundred) number of collected observations, current machine learning strategies benefit greatly from dimensionality reduction data preprocessing steps. Besides dimensionality reduction, there has not been much consideration for useful feature engineering strategies. Equivalent electrical circuit parameters, which contain the information from the impedance spectra after being fit, and distribution time constants are two interesting feature engineering strategies that can be evaluated in future work. A general remark on the machine learning approaches where classification is performed for ordinal outcomes, such as fruit ripeness or heartwood content of Scotts pine and the health state of oil palms (Khaled et al., 2018), is that the authors did not take the ordinality of the outcome variables into account (Frank and Hall, 2001). An exemplary consequence of neglecting this ordinality is that the misclassification of an overripe avocado as a firm avocado is not considered to be a larger error than the misclassification of a ripe avocado as an overripe avocado. Ordinality should be considered during the model development and evaluation stages (Cardoso and Sousa, 2011).

A few other criticisms of the works presented in Table 3 are that i) sometimes no validation of the calibrated models on external datasets was performed (Basak et al., 2020b), ii) the necessary unit of the response variable when reporting the RMSE is often omitted, and iii) the results of some of the classification accuracies should be taken with a grain of salt, as the artificial classification settings may not be representative of actual practice. An example is the evaluation of freeze injury in citrus fruits. If the authors subject the fruits to intense freeze treatments, the differences between the impedance spectra of the two classes (damaged and non-damaged) are very large, such that even a simple model could achieve high classification performance. In this case, it is uncertain how the model would perform when faced with observations where the fruits are subjected to a lesser extent of freeze treatment.

Artificial neural networks are often reported in the new machine-learning-based impedimetric fruit quality monitoring trend. These appear to always be fully connected multi-layer perceptrons. Given the time-series nature of the EIS signals, other architectures, such as convolutional neural networks (CNN) or recurrent neural networks (RNN), may be more effective, as they have demonstrated high predictive performance in similar signal processing problem settings (Kiranyaz et al., 2019; Zhang et al., 2019).

Few studies have evaluated which non-destructive plant characterization methods complement each other well, bearing in mind the trade-off between increased depth and performance of a combination of complementary methods on the one hand and the increased labor and costs on the other hand (Srivastava and Sadistap, 2022). The rapid development and miniaturization of sensors and equipment hold promise for in situ applications and online operando plant monitoring. IoT data from different measured environmental variables (e.g., images, temperature, light intensity, and humidity) can be combined with electrochemical properties for agricultural management decision making, focusing on uncertainty quantification and interpretability in a bespoke probabilistic model in “smart farms” and greenhouses. As such, we can obtain highly accurate plant variables and quantifiable uncertainty, allowing for informed farm management decisions. To this end, we can take inspiration from Li-ion battery state of health research, where the authors probabilistically determined the state of health of the battery using impedance parameters in addition to the temperature and the state of charge of the battery (Zhang et al., 2022). If such models prove robust and reliable, it will lead to further advances in automation in “smart farms”.

6 Conclusion and future perspectives

A great deal of information on the physiological status of plants is contained in their electrochemical impedance spectra. One of the main challenges for plant EIS practitioners is extracting this information. In this work, we first provided an overview of the various physicochemical properties of plants that can be interrogated by EIS measurement on various plant organs. We then provided an overview of plant equivalent electrical circuit analysis as well as statistical and more recent machine learning approaches.

This paper proposed several suggestions to transfer knowledge and progress from the field of electrochemical power sources, which constitutes the most active area in EIS modeling research, to plant applications. These include adopting validation strategies, the fractionalization of equivalent circuit models, and the novel DRT method.

Author contributions

MVH: conceptualization, writing – original draft. BDB: conceptualization, writing – editing, supervision. MS: conceptualization, writing – editing, supervision. All authors contributed to the article and approved the submitted version.

Funding

This work was supported by FWO-Vlaanderen under grant FWO-SBO S007019N (Bisceps).

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Footnotes

  1. ^ Here, we consider potentiostatic EIS, while in galvanostatic EIS the input is an alternating current.

References

AboBakr, A., Said, L. A., Madian, A. H., Elwakil, A. S., Radwan, A. G. (2017). Experimental comparison of integer/fractional-order electrical models of plant. AEU-International J. Electron. Commun. 80, 1–9. doi: 10.1016/j.aeue.2017.06.010

CrossRef Full Text | Google Scholar

Abramovic, B., Jajic, I., Abramovic, B., Cosic, J., Juric, V. (2007). Detection of deoxynivalenol in wheat by fourier transform infrared spectroscopy. Acta Chimica Slovenica 54 (4), 859.

Google Scholar

Afzal, A., Duiker, S. W., Watson, J. E., Luthe, D. (2017). Leaf thickness and electrical capacitance as measures of plant water status. Trans. ASABE 60 (4), 1063–1074. doi: 10.13031/trans.12083

CrossRef Full Text | Google Scholar

Agati, G., Foschi, L., Grossi, N., Volterrani, M. (2015). In field non-invasive sensing of the nitrogen status in hybrid bermudagrass (cynodon dactylon× c. transvaalensis burtt davy) by a fluorescence-based method. Eur. J. Agron. 63, 89–96. doi: 10.1016/j.eja.2014.11.007

CrossRef Full Text | Google Scholar

Ali, M., Al-Ani, A., Eamus, D., Tan, D. K. (2017). Leaf nitrogen determination using non-destructive techniques–a review. J. Plant Nutr. 40 (7), 928–953. doi: 10.1080/01904167.2016.1143954

CrossRef Full Text | Google Scholar

Ali, M. M., Bachik, N. A., Muhadi, N., Yusof, T. N. T., Gomes, C. (2019). Non-destructive techniques of detecting plant diseases: a review. Physiol. Mol. Plant Pathol. 108, 101426. doi: 10.1016/j.pmpp.2019.101426

CrossRef Full Text | Google Scholar

Ali Solangi, K., Wu, Y., Chen, Q., Ahmed Qureshi, W., Xing, D., Hussain Tunio, M., et al. (2021). The differential responses of aegiceras corniculatum and kandelia candel under salt stress and re-watering phase. a study of leaf electrophysiological and growth parameters. J. Plant Interact. 16 (1), 307–320. doi: 10.1080/17429145.2021.1946606

CrossRef Full Text | Google Scholar

Ando, Y., Maeda, Y., Mizutani, K., Wakatsuki, N., Hagiwara, S., Nabetani, H. (2016). Effect of air-dehydration pretreatment before freezing on the electrical impedance characteristics and texture of carrots. J. Food Eng. 169, 114–121. doi: 10.1016/j.jfoodeng.2015.08.026

CrossRef Full Text | Google Scholar

Ando, Y., Mizutani, K., Wakatsuki, N. (2014). Electrical impedance analysis of potato tissues during drying. J. Food Eng. 121, 24–31. doi: 10.1016/j.jfoodeng.2013.08.008

CrossRef Full Text | Google Scholar

Angersbach, A., Heinz, V., Knorr, D. (1999). Electrophysiological model of intact and processed plant tissues: cell disintegration criteria. Biotechnol. Prog. 15 (4), 753–762. doi: 10.1021/bp990079f

PubMed Abstract | CrossRef Full Text | Google Scholar

Aouane, S., Claverie, R., Techer, D., Durickovic, I., Rousseau, L., Poulichet, P., et al. (2021). “Cole-Cole parameter extraction from electrical impedance spectroscopy for real-time monitoring of vegetal tissue: case study with a single celery stalk,” in 2021 International Workshop on Impedance Spectroscopy (IWIS). (Chemnitz, Germany: IEEE). 48–51. doi: 10.1109/IWIS54661.2021.9711854

CrossRef Full Text | Google Scholar

Aparisi, P. A., Sánchez, E. F., Rodrigo, L. C., Peris, R. M., Laguarda-Miro, N. (2021). A rapid electrochemical impedance spectroscopy and sensor-based method for monitoring freeze-damage in tangerines. IEEE Sensors J. 21 (10), 12009–12018. doi: 10.1109/JSEN.2021.3065846

CrossRef Full Text | Google Scholar

Apweiler, R., Bairoch, A., Wu, C. H., Barker, W. C., Boeckmann, B., Ferro, S., et al. (2004). Uniprot: the universal protein knowledgebase. Nucleic Acids Res. 32, D115–D119. doi: 10.1093/nar/gkaa1100

PubMed Abstract | CrossRef Full Text | Google Scholar

Arteaga, H., Robleto-Martinez, E., de Sousa Silva, A. C., Souto, S., Batista, J., Costa, E. J. X. (2021). Postharvest freezing process assessment of the blueberry structure in three acts: bioimpedance, color, and granulometry analysis. LWT 151, 112237. doi: 10.1016/j.lwt.2021.112237

CrossRef Full Text | Google Scholar

Astashev, M. E., Konchekov, E. M., Kolik, L. V., Gudkov, S. V. (2022). Electric impedance spectroscopy in trees condition analysis: theory and experiment. Sensors 22 (21), 8310. doi: 10.3390/s22218310

PubMed Abstract | CrossRef Full Text | Google Scholar

Azzarello, E., Mugnai, S., Pandolfi, C., Masi, E., Mancuso, S.. (2006). Stress assessment in plants by impedance spectroscopy. Floricult. Ornamental Plant Biotechnol. 3, 140–148.

Google Scholar

Bacci, L., De Vincenzi, M., Rapi, B., Arca, B., Benincasa, F. (1998). Two methods for the analysis of colorimetric components applied to plant stress monitoring. Comput. Electron. Agric. 19 (2), 167–186. doi: 10.1016/S0168-1699(97)00042-2

CrossRef Full Text | Google Scholar

Bar-On, L., Garlando, U., Sophocleous, M., Jog, A., Motto Ros, P., Sade, N., et al. (2021). Electrical modelling of in-vivo impedance spectroscopy of Nicotiana tabacum plants. Front. Electron. 2, 753145. doi: 10.3389/felec.2021.753145

CrossRef Full Text | Google Scholar

Barsoukov, E., Macdonald, J. R. (2018). Impedance spectroscopy: theory, experiment, and applications (Hoboken, New Jersey: John Wiley & Sons).

Google Scholar

Basak, R., Wahid, K., Dinh, A. (2020b). Determination of leaf nitrogen concentrations using electrical impedance spectroscopy in multiple crops. Remote Sens. 12 (3), 566. doi: 10.3390/rs12030566

CrossRef Full Text | Google Scholar

Basak, R., Wahid, K. A., Dinh, A., Soolanayakanahally, R., Fotouhi, R., Mehr, A. S. (2020a). Rapid and efficient determination of relative water contents of crop leaves using electrical impedance spectroscopy in vegetative growth stage. Remote Sens. 12 (11), 1753. doi: 10.3390/rs12111753

CrossRef Full Text | Google Scholar

Bausch, W. C., Halvorson, A. D., Cipra, J. (2008). Quickbird satellite and ground-based multispectral data correlations with agronomic parameters of irrigated maize grown in small plots. Biosyst. Eng. 101 (3), 306–315. doi: 10.1016/j.biosystemseng.2008.09.011

CrossRef Full Text | Google Scholar

Belasque, J., Gasparoto, M., Marcassa, L. G. (2008). Detection of mechanical and disease stresses in citrus plants by fluorescence spectroscopy. Appl. Optics 47 (11), 1922–1926. doi: 10.1364/AO.47.001922

CrossRef Full Text | Google Scholar

Benalia, S., Cubero, S., Prats-Montalbán, J. M., Bernardi, B., Zimbalatti, G., Blasco, J. (2016). Computer vision for automatic quality inspection of dried figs (ficus carica l.) in real-time. Comput. Electron. Agric. 120, 17–25. doi: 10.1016/j.compag.2015.11.002

CrossRef Full Text | Google Scholar

Benson, D. A., Cavanaugh, M., Clark, K., Karsch-Mizrachi, I., Lipman, D. J., Ostell, J., et al. (2012). Genbank. Nucleic Acids Res. 41 (D1), D36–D42. doi: 10.1093/nar/gkq1079

PubMed Abstract | CrossRef Full Text | Google Scholar

Bishop, C. M., Nasrabadi, N. M. (2006). Pattern recognition and Machine Learning Vol. 4 (Singapore: Springer).

Google Scholar

Bodale, I., Mihalache, G., Achiţei, V., Teliban, G. C., Cazacu, A., Stoleru, V. (2021). Evaluation of the nutrients uptake by tomato plants in different phenological stages using an electrical conductivity technique. Agriculture 11 (4), 292. doi: 10.3390/agriculture11040292

CrossRef Full Text | Google Scholar

Bondarenko, A., Ragoisha, G. (2005). Potentiodynamic Electrochemical Impedance Spectroscopy (New York: Nova Science). http://www.abc.chemistry.bsu.by/vi/.

Google Scholar

Borges, E., Matos, A., Cardoso, J., Correia, C., Vasconcelos, T., Gomes, N. (2012). “Early detection and monitoring of plant diseases by bioelectric impedance spectroscopy,” in 2012 IEEE 2nd Portuguese Meeting in Bioengineering (ENBENG). (Coimbra, Portugal: IEEE), 1–4. doi: 10.1109/ENBENG.2012.6331377

CrossRef Full Text | Google Scholar

Brug, G., van den Eeden, A. L., Sluyters-Rehbach, M., Sluyters, J. H. (1984). The analysis of electrode impedances complicated by the presence of a constant phase element. J. Electroanalytical Chem. Interfacial Electrochem. 176 (1-2), 275–295. doi: 10.1016/s0022-0728(84)80324-1

CrossRef Full Text | Google Scholar

Bürling, K., Hunsche, M., Noga, G. (2012). Presymptomatic detection of powdery mildew infection in winter wheat cultivars by laser-induced fluorescence. Appl. Spectrosc. 66 (12), 1411–1419. doi: 10.1366/12-06614

PubMed Abstract | CrossRef Full Text | Google Scholar

Butler, H. J., Adams, S., McAinsh, M. R., Martin, F. L. (2017). Detecting nutrient deficiency in plant systems using synchrotron fourier-transform infrared microspectroscopy. Vibrational Spectrosc. 90, 46–55. doi: 10.1016/j.vibspec.2017.03.004

CrossRef Full Text | Google Scholar

Buysse, J., Merckx, R. (1993). An improved colorimetric method to quantify sugar content of plant tissue. J. Exp. Bot. 44 (10), 1627–1629. doi: 10.1093/jxb/44.10.1627

CrossRef Full Text | Google Scholar

Cabrera-López, J. J., Velasco-Medina, J. (2019). Structured approach and impedance spectroscopy microsystem for fractional-order electrical characterization of vegetable tissues. IEEE Trans. Instrumentation Measurement 69 (2), 469–478. doi: 10.1109/TIM.2019.2904131

CrossRef Full Text | Google Scholar

Cao, Y., Repo, T., Silvennoinen, R., Lehto, T., Pelkonen, P. (2011). Analysis of the willow root system by electrical impedance spectroscopy. J. Exp. Bot. 61 (9), 351–358. doi: 10.1093/jxb/erq276

CrossRef Full Text | Google Scholar

Caravia, L., Collins, C., Tyerman, S. (2015). Electrical impedance of shiraz berries correlates with decreasing cell vitality during ripening. Aust. J. Grape Wine Res. 21 (3), 430–438. doi: 10.1111/ajgw.12157

CrossRef Full Text | Google Scholar

Cardoso, J. S., Sousa, R. (2011). Measuring the performance of ordinal classification. Int. J. Pattern Recognition Artif. Intell. 25 (08), 1173–1195. doi: 10.1142/S0218001411009093

CrossRef Full Text | Google Scholar

Cavalieri, R., Bertemes-Filho, P. (2020). Plant tissue differentiation using electrical impedance spectroscopy with deep neural networks. Int. J. Biosensors Bioelectronics 6 (1), 20–23. doi: 10.15406/ijbsbe.2020.06.00182

CrossRef Full Text | Google Scholar

Cavalieri, R., Bertemes-Filho, P. (2021). “Dimensionality reduction methods for impedance spectroscopy data of biological materials,” in Journal of physics: conference series (San Luis Potosí, Mexico: IOP Publishing), 012009. doi: 10.1088/1742-6596/2008/1/012009

CrossRef Full Text | Google Scholar

Chaerle, L., Hagenbeek, D., Vanrobaeys, X., van der Straeten, D. (2007). Early detection of nutrient and biotic stress in phaseolus vulgaris. Int. J. Remote Sens. 28 (16), 3479–3492. doi: 10.1080/01431160601024259

CrossRef Full Text | Google Scholar

Chaerle, L., Pineda, M., Romero-Aranda, R., van der Straeten, D., Baron, M. (2006). Robotized thermal and chlorophyll fluorescence imaging of pepper mild mottle virus infection in nicotiana benthamiana. Plant Cell Physiol. 47 (9), 1323–1336. doi: 10.1093/pcp/pcj102

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, L., Huang, S., Sun, Y., Zhu, E., Wang, K. (2019). Rapid identification of potassium nutrition stress in rice based on machine vision and object-oriented segmentation. J. Spectrosc. 2019, 4623545. doi: 10.1155/2019/4623545

CrossRef Full Text | Google Scholar

Cheng, J., Yu, P., Huang, Y., Zhang, G., Lu, C., Jiang, X. (2022). Application status and prospect of impedance spectroscopy in agricultural product quality detection. Agriculture 12 (10), 1525. doi: 10.3390/agriculture12101525

CrossRef Full Text | Google Scholar

Chin-Hashim, N. F., Khaled, A. Y., Jamaludin, D., Abd Aziz, S. (2022). Electrical impedance spectroscopy for moisture and oil content prediction in oil palm (elaeis guineensis jacq.) fruitlets. Plants 11 (23), 3373. doi: 10.3390/plants11233373

PubMed Abstract | CrossRef Full Text | Google Scholar

Choi, M., Carver, J., Chiva, C., Tzouros, M., Huang, T., Tsai, T. H., et al. (2020). MassIVE. quant: a community resource of quantitative mass spectrometry–based proteomics datasets. Nat. Methods 17 (10), 981–984. doi: 10.1038/s41592-020-0955-0

PubMed Abstract | CrossRef Full Text | Google Scholar

Chowdhury, R. I., Basak, R., Wahid, K. A., Nugent, K., Baulch, H. (2021). A rapid approach to measure extracted chlorophyll-a from lettuce leaves using electrical impedance spectroscopy. Water Air Soil pollut. 232 (2), 1–12. doi: 10.1007/s11270-021-05036-z

CrossRef Full Text | Google Scholar

Cole, K. S. (1940). “Permeability and impermeability of cell membranes for ions,” in Cold Spring Harbor Symposia on Quantitative Biology. (Long Island, New York: Cold Spring Harbor Laboratory Press), Vol. 8, 110–122.

Google Scholar

Cole, K. S. (1968). “Membranes, ions and impulses,” in Classical biophysics. Ed. Lastname, E. F. (Los Angeles, Calif: University of California Press, Berkeley), 12. doi: 10.1525/9780520326514

CrossRef Full Text | Google Scholar

Cole, K. S., Cole, R. H. (1941). Dispersion and absorption in dielectrics i. alternating current characteristics. J. Chem. Phys. 9 (4), 341–351. doi: 10.1063/1.1750906

CrossRef Full Text | Google Scholar

Conesa, C., Ibanez Civera, J., Seguí, L., Fito, P., Laguarda-Miró, N. (2016). An electrochemical impedance spectroscopy system for monitoring pineapple waste saccharification. Sensors 16 (2), 188. doi: 10.3390/s16020188

PubMed Abstract | CrossRef Full Text | Google Scholar

Cseresnyés, I., Pokovai, K., Bányai, J., Mikó, P. (2022). Root electrical capacitance can be a promising plant phenotyping parameter in wheat. Plants 11 (21), 2975. doi: 10.3390/plants11212975

PubMed Abstract | CrossRef Full Text | Google Scholar

Cseresnyés, I., Szitár, K., Rajkai, K., Füzy, A., Mikó, P., Kovács, R., et al. (2018). Application of electrical capacitance method for prediction of plant root mass and activity in field-grown crops. Front. Plant Sci. 9, 93. doi: 10.3389/fpls.2018.00093

PubMed Abstract | CrossRef Full Text | Google Scholar

Cseri, A., Sass, L., Torjek, O., Pauk, J., Vass, I., Dudits, D. (2013). Monitoring drought responses of barley genotypes with semi-robotic phenotyping platform and association analysis between recorded traits and allelic variants of some stress genes. Aust. J. Crop Sci., 1560–1570. doi: 10.3316/informit.619120292011087

CrossRef Full Text | Google Scholar

de Lacy Costello, B., Ewen, R., Gunson, H., Ratcliffe, N. M., Spencer-Phillips, P. T. (2000). The development of a sensor system for the early detection of soft rot in stored potato tubers. Measurement Sci. Technol. 11 (12), 1685. doi: 10.1088/0957-0233/11/12/305

CrossRef Full Text | Google Scholar

De Swaef, T., Pieters, O., Appeltans, S., Borra-Serrano, I., Coudron, W., Couvreur, V., et al. (2022). On the pivotal role of water potential to model plant physiological processes. silico Plants 4 (1), diab038. doi: 10.1093/insilicoplants/diab038

CrossRef Full Text | Google Scholar

Dietrich, R., Bengough, A., Jones, H., White, P. (2013). Can root electrical capacitance be used to predict root mass in soil? Ann. Bot. 112 (2), 457–464. doi: 10.1093/aob/mct044

PubMed Abstract | CrossRef Full Text | Google Scholar

Di Natale, C., Macagnano, A., Martinelli, E., Paolesse, R., Proietti, E., D’Amico, A. (2001). The evaluation of quality of post-harvest oranges and apples by means of an electronic nose. Sensors Actuators B: Chem. 78 (1-3), 26–31. doi: 10.1016/S0925-4005(01)00787-0

CrossRef Full Text | Google Scholar

Ehosioke, S., Nguyen, F., Rao, S., Kremer, T., Placencia-Gomez, E., Huisman, J. A., et al. (2020). Sensing the electrical properties of roots: a review. Vadose Zone J. 19 (1), e20082. doi: 10.1002/vzj2.20082

CrossRef Full Text | Google Scholar

El-Hendawy, S. E., Al-Suhaibani, N. A., Hassan, W. M., Dewir, Y. H., Elsayed, S., Al-Ashkar, I., et al. (2019). Evaluation of wavelengths and spectral reflectance indices for high-throughput assessment of growth, water relations and ion contents of wheat irrigated with saline water. Agric. Water Manage. 212, 358–377. doi: 10.1016/j.agwat.2018.09.009

CrossRef Full Text | Google Scholar

Elijah, O., Rahman, T. A., Orikumhi, I., Leow, C. Y., Hindia, M. N. (2018). An overview of internet of things (iot) and data analytics in agriculture: benefits and challenges. IEEE Internet Things J. 5 (5), 3758–3773. doi: 10.1109/JIOT.2018.2844296

CrossRef Full Text | Google Scholar

El Khaled, D., Castellano, N., Gazquez, J., Salvador, R. G., Manzano-Agugliaro, F. (2017). Cleaner quality control system using bioimpedance methods: a review for fruits and vegetables. J. Cleaner Production 140, 1749–1762. doi: 10.1016/j.jclepro.2015.10.096

CrossRef Full Text | Google Scholar

Feng, L., Hou, T., Wang, B., Zhang, B. (2021). Assessment of rice seed vigour using selected frequencies of electrical impedance spectroscopy. Biosyst. Eng. 209, 53–63. doi: 10.1016/j.biosystemseng.2021.06.011

CrossRef Full Text | Google Scholar

Fletcher, S. (1994). Tables of degenerate electrical networks for use in the equivalent-circuit analysis of electrochemical systems. J. Electrochemical Soc. 141 (7), 1823. doi: 10.1149/1.2055011

CrossRef Full Text | Google Scholar

Foster, K., Schwan, H. (1989). Dielectric-properties of tissues and biological-materials - a critical-review. Crit. Rev. Biomed. Eng. 17 (1), 25–104.

PubMed Abstract | Google Scholar

Frank, E., Hall, M. (2001). “A simple approach to ordinal classification,” in European Conference on Machine Learning (Freiburg, Germany: Springer), 145–156. doi: 10.1007/3-540-44795-413

CrossRef Full Text | Google Scholar

Freeborn, T. J. (2013). A survey of fractional-order circuit models for biology and biomedicine. IEEE J. Emerging Selected Topics Circuits Syst. 3 (3), 416–424. doi: 10.1109/JETCAS.2013.2265797

CrossRef Full Text | Google Scholar

Freeborn, T. J., Maundy, B., Elwakil, A. S. (2013). Cole Impedance extractions from the step-response of a current excited fruit sample. Comput. Electron. Agric. 98, 100–108. doi: 10.1016/j.compag.2013.07.017

CrossRef Full Text | Google Scholar

Gabriel, C., Gabriel, S. (1996). Compilation of the dielectric properties of body tissues at rf and microwave frequencies. Tech. Rep (London, United Kingdom: King’s College London Department of Physics).

Google Scholar

Gadallah, S. I., Ghoneim, M. S., Elwakil, A. S., Said, L. A., Madian, A. H., Radwan, A. G. (2022). Plant tissue modelling using power-law filters. Sensors 22 (15), 5659. doi: 10.3390/s22155659

PubMed Abstract | CrossRef Full Text | Google Scholar

Ghoneim, M. S., Gadallah, S. I., Said, L. A., Eltawil, A. M., Radwan, A. G., Madian, A. H. (2022). Plant stem tissue modeling and parameter identification using metaheuristic optimization algorithms. Sci. Rep. 12 (1), 3992. doi: 10.1038/s41598-022-06737-z

PubMed Abstract | CrossRef Full Text | Google Scholar

Gonçalves, B., Silva, A. P., Moutinho-Pereira, J., Bacelar, E., Rosa, E., Meyer, A. S. (2007). Effect of ripeness and postharvest storage on the evolution of colour and anthocyanins in cherries (prunus avium l.). Food Chem. 103 (3), 976–984. doi: 10.1016/j.foodchem.2006.08.039

CrossRef Full Text | Google Scholar

González-Araiza, J. R., Ortiz-Sánchez, M. C., Vargas-Luna, F. M., Cabrera-Sixto, J. M. (2017). Application of electrical bio-impedance for the evaluation of strawberry ripeness. Int. J. Food Properties 20 (5), 1044–1050. doi: 10.1080/10942912.2016.1199033

CrossRef Full Text | Google Scholar

Goodfellow, I., Bengio, Y., Courville, A. (2016). Deep Learning (Massachusetts, USA: MIT press).

Google Scholar

Granum, E., Pérez-Bueno, M. L., Calderón, C. E., Ramos, C., de Vicente, A., Cazorla, F. M., et al. (2015). Metabolic responses of avocado plants to stress induced by rosellinia necatrix analysed by fluorescence and thermal imaging. Eur. J. Plant Pathol. 142 (3), 625–632. doi: 10.1007/s10658-015-0640-9

CrossRef Full Text | Google Scholar

Guo, W., Shang, L., Zhu, X., Nelson, S. O. (2015). Nondestructive detection of soluble solids content of apples from dielectric spectra with ann and chemometric methods. Food Bioprocess Technol. 8 (5), 1126–1138. doi: 10.1007/s11947-015-1477-0

CrossRef Full Text | Google Scholar

Gutiérrez, S., Wendel, A., Underwood, J. (2019). Spectral filter design based on in-field hyperspectral imaging and machine learning for mango ripeness estimation. Comput. Electron. Agric. 164, 104890. doi: 10.1016/j.compag.2019.104890

CrossRef Full Text | Google Scholar

Hamed, K. B., Zorrig, W., Hamzaoui, A. H. (2016). Electrical impedance spectroscopy: a tool to investigate the responses of one halophyte to different growth and stress conditions. Comput. Electron. Agric. 123, 376–383. doi: 10.1016/j.compag.2016.03.006

CrossRef Full Text | Google Scholar

Hao, Y., Hua, Y., Li, X., Gao, X., Chen, J. (2021). Electrical properties predict wheat leaf moisture. Trans. ASABE 64 (3), 929–936. doi: 10.13031/trans.14210

CrossRef Full Text | Google Scholar

Harker, F. R., Forbes, S. K. (1997). Ripening and development of chilling injury in persimmon fruit: an electrical impedance study. New Z. J. Crop Hortic. Sci. 25 (2), 149–157. doi: 10.1080/01140671.1997.9514001

CrossRef Full Text | Google Scholar

Harker, F. R., Maindonald, J. H. (1994). Ripening of nectarine fruit (changes in the cell wall, vacuole, and membranes detected using electrical impedance measurements). Plant Physiol. 106 (1), 165–171. doi: 10.1104/pp.106.1.165

PubMed Abstract | CrossRef Full Text | Google Scholar

Hashimoto, Y., Ino, T., Kramer, P. J., Naylor, A. W., Strain, B. R. (1984). Dynamic analysis of water stress of sunflower leaves by means of a thermal image processing system. Plant Physiol. 76 (1), 266–269. doi: 10.1104/pp.76.1.266

PubMed Abstract | CrossRef Full Text | Google Scholar

Hayden, R., Moyse, C., Calder, F., Crawford, D., Fensom, D. (1969). Electrical impedance studies on potato and alfalfa tissue. J. Exp. Bot. 20 (2), 177–200. doi: 10.1093/jxb/20.2.177

CrossRef Full Text | Google Scholar

Hirschorn, B., Orazem, M. E., Tribollet, B., Vivier, V., Frateur, I., Musiani, M. (2010). Determination of effective capacitance and film thickness from constant-phase-element parameters. Electrochim. Acta 55 (21), 6218–6227. doi: 10.1016/j.electacta.2009.10.065

CrossRef Full Text | Google Scholar

Hsu, C., Mansfeld, F. (2001). Concerning the conversion of the constant phase element parameter y0 into a capacitance. Corrosion 57 (09). doi: 10.5006/1.3280607

CrossRef Full Text | Google Scholar

Humplík, J. F., Lazár, D., Husičková, A., Spíchal, L. (2015). Automated phenotyping of plant shoots using imaging methods for analysis of plant stress responses–a review. Plant Methods 11 (1), 1–10. doi: 10.1186/s13007-015-0072-8

PubMed Abstract | CrossRef Full Text | Google Scholar

Huong, H., Teerachaichayut, S. (2016). “Non-destructive prediction of moisture content of lime (citrus aurantifolia swingle’paan’) by multiple regression analysis of its electrical and physical properties,” in III International Conference on Agricultural and Food Engineering (Kuala Lumpur, Malaysia: International Society for Horticultural Science), Vol. 1152. 299–306. doi: 10.17660/ActaHortic.2017.1152.40

CrossRef Full Text | Google Scholar

Hussain, M. I., El-Keblawy, A., Akhtar, N., Elwakil, A. S. (2021). Electrical impedance spectroscopy in plant biology. Sustain. Agric. Rev. 12 (1), 395–416. doi: 10.1007/978-3-030-73245-5_12

CrossRef Full Text | Google Scholar

Hytönen, J., Wall, A. (2006). Foliar colour as indicator of nutrient status of scots pine (pinus sylvestris l.) on peatlands. For. Ecol. Manage. 237, 156–163. doi: 10.1016/j.foreco.2006.09.041

CrossRef Full Text | Google Scholar

Ibba, P., Falco, A., Abera, B. D., Cantarella, G., Petti, L., Lugli, P. (2020). Bio-impedance and circuit parameters: an analysis for tracking fruit ripening. Postharvest Biol. Technol. 159, 110978. doi: 10.1016/j.postharvbio.2019.110978

CrossRef Full Text | Google Scholar

Ibba, P., Tronstad, C., Moscetti, R., Mimmo, T., Cantarella, G., Petti, L., et al. (2021). Supervised binary classification methods for strawberry ripeness discrimination from bioimpedance data. Sci. Rep. 11 (1), 1–13. doi: 10.1038/s41598-021-90471-5

PubMed Abstract | CrossRef Full Text | Google Scholar

Imaizumi, T., Tanaka, F., Hamanaka, D., Sato, Y., Uchino, T. (2015). Effects of hot water treatment on electrical properties, cell membrane structure and texture of potato tubers. J. Food Eng. 162, 56–62. doi: 10.1016/j.jfoodeng.2015.04.003

CrossRef Full Text | Google Scholar

Inaba, A., Manabe, T., Tsuji, H., Iwamoto, T. (1995). Electrical impedance analysis of tissue properties associated with ethylene induction by electric currents in cucumber (cucumis sativus l.) fruit. Plant Physiol. 107 (1), 199–205. doi: 10.1104/pp.107.1.199

PubMed Abstract | CrossRef Full Text | Google Scholar

Ishaq, I., Alias, M., Kadir, J., Kasawani, I. (2014). Detection of basal stem rot disease at oil palm plantations using sonic tomography. J. Sustainability Sci. Manage. 9 (2), 52–57.

Google Scholar

Islam, M., Wahid, K., Dinh, A. (2018). Assessment of ripening degree of avocado by electrical impedance spectroscopy and support vector machine. J. Food Qual. 4706147. doi: 10.1155/2018/4706147

CrossRef Full Text | Google Scholar

Islam, M., Wahid, K. A., Dinh, A. V., Bhowmik, P. (2019). Model of dehydration and assessment of moisture content on onion using EIS. J. Food Sci. Technol. 56 (6), 2814–2824. doi: 10.1007/s13197-019-03590-3

PubMed Abstract | CrossRef Full Text | Google Scholar

Ivanovski, T., Zhang, G., Jemrić, T., Gulić, M., Matetić, M. (2020). “Fruit firmness prediction using multiple linear regression,” in 43rd International Convention on Information, Communication and Electronic Technology (MIPRO). (Opatija, Croatia: IEEE), 1306–1311. doi: 10.23919/MIPRO48935.2020.9245213

CrossRef Full Text | Google Scholar

Ivanovski, T., Zhang, X., Jemrić, T., Gulić, M., Matetić, M. (2022). “Peach firmness prediction using optimized regression trees models,” in 33rd DAAAM International symposium (DAAAM International). doi: 10.2507/33rd.daaam.proceedings.067

CrossRef Full Text | Google Scholar

Jacobi, J., Kühbauch, W., Stafford, J. (2005). Site-specific identification of fungal infection and nitrogen deficiency in wheat crop using remote sensing. Precis. Agric. 5, 73–80.

Google Scholar

Jamaludin, D., Abd Aziz, S., Ibrahim, N. (2014). Dielectric based sensing system for banana ripeness assessment. Int. J. Environ. Sci. Dev. 5 (3), 286. doi: 10.7763/IJESD.2014.V5.493

CrossRef Full Text | Google Scholar

Jin, X., Shi, C., Yu, C. Y., Yamada, T., Sacks, E. J. (2017). Determination of leaf water content by visible and near-infrared spectrometry and multivariate calibration in miscanthus. Front. Plant Sci. 8, 721. doi: 10.3389/fpls.2017.00721

PubMed Abstract | CrossRef Full Text | Google Scholar

Jinyang, L., Meiqing, L., Hanping, M., Wenjing, Z. (2016). Diagnosis of potassium nutrition level in solanum lycopersicum based on electrical impedance. Biosyst. Eng. 147, 130–138. doi: 10.1016/j.biosystemseng.2016.04.005

CrossRef Full Text | Google Scholar

Jócsák, I., Droppa, M., Horváth, G., Bóka, K., Vozáry, E. (2010). Cadmium-and flood-induced anoxia stress in pea roots measured by electrical impedance. Z. für Naturforschung C 65 (1-2), 95–102. doi: 10.1515/znc-2010-1-216

CrossRef Full Text | Google Scholar

Jócsák, I., Végvári, G., Vozáry, E. (2019). Electrical impedance measurement on plants: a review with some insights to other fields. Theor. Exp. Plant Physiol. 31 (3), 359–375. doi: 10.1007/s40626-019-00152-y

CrossRef Full Text | Google Scholar

Johnson, D. (2000). Zplot, ZView electrochemical impedance software, version 2.3. software.

Google Scholar

Juansah, J., Budiastra, I. W., Dahlan, K., Seminar, K. B. (2012). Electrical behavior of garut citrus fruits during ripening changes in resistance and capacitance models of internal fruits. IJET-IJENS 12 (4), 1–8.

Google Scholar

Khaled, A. Y., Abd Aziz, S., Bejo, S. K., Mat Nawi, N., Abu Seman, I. (2022). Artificial intelligence for spectral classification to identify the basal stem rot disease in oil palm using dielectric spectroscopy measurements. Trop. Plant Pathol. 47 (1), 140–151. doi: 10.1007/s40858-021-00445-1

CrossRef Full Text | Google Scholar

Khaled, A. Y., Abd Aziz, S., Bejo, S. K., Nawi, N. M., Seman, I. A. (2018). Spectral features selection and classification of oil palm leaves infected by basal stem rot (BSR) disease using dielectric spectroscopy. Comput. Electron. Agric. 144, 297–309. doi: 10.1016/j.compag.2017.11.012

CrossRef Full Text | Google Scholar

Kiranyaz, S., Ince, T., Abdeljaber, O., Avci, O., Gabbouj, M. (2019). “1-d convolutional neural networks for signal processing applications,” in ICASSP 2019-2019 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP). (Brighton, United Kingdom: IEEE), 8360–8364. doi: 10.1109/ICASSP.2019.8682194

CrossRef Full Text | Google Scholar

Kodosky, J. (2020). Labview. Proc. ACM Programming Languages 4 (HOPL), 1–54. doi: 10.1145/3386328

CrossRef Full Text | Google Scholar

Korimbocus, J., Coates, D., Barker, I., Boonham, N. (2002). Improved detection of sugarcane yellow leaf virus using a real-time fluorescent (taqman) rt-pcr assay. J. Virological Methods 103 (2), 109–120. doi: 10.1016/S0166-0934(01)00406-2

CrossRef Full Text | Google Scholar

Kovar, M., Brestic, M., Sytar, O., Barek, V., Hauptvogel, P., Zivcak, M. (2019). Evaluation of hyperspectral reflectance parameters to assess the leaf water content in soybean. Water 11 (3), 443. doi: 10.3390/w11030443

CrossRef Full Text | Google Scholar

Kronig, R. (1926). On the theory of dispersion of x-rays. Josa 12 (6), 547–557. doi: 10.1364/JOSA.12.000547

CrossRef Full Text | Google Scholar

Kuang, W., Nelson, S. (1998). Low-frequency dielectric properties of biological tissues: a review with some new insights. Trans. ASAE 41 (1), 173–184. doi: 10.13031/2013.17142

CrossRef Full Text | Google Scholar

Kuson, P., Terdwongworakul, A. (2013). Minimally-destructive evaluation of durian maturity based on electrical impedance measurement. J. Food Eng. 116 (1), 50–56. doi: 10.1016/j.jfoodeng.2012.11.021

CrossRef Full Text | Google Scholar

Lakshmi, S., Pandey, A., Ravi, N., Chauhan, O., Gopalan, N., Sharma, R. (2017). Non-destructive quality monitoring of fresh fruits and vegetables. Defence Life Sci. J. 2 (2), 103–110. doi: 10.14429/dlsj.2.11379

CrossRef Full Text | Google Scholar

Lan, H., Wang, Z., Niu, H., Zhang, H., Zhang, Y., Tang, Y., et al. (2020). A nondestructive testing method for soluble solid content in korla fragrant pears based on electrical properties and artificial neural network. Food Sci. Nutr. 8 (9), 5172–5181. doi: 10.1002/fsn3.1822

PubMed Abstract | CrossRef Full Text | Google Scholar

Lazanas, A. C., Prodromidis, M. I. (2023). Electrochemical impedance spectroscopy─ a tutorial. ACS Measurement Sci. Au. 3, 162–193. doi: 10.1021/acsmeasuresciau.2c00070

CrossRef Full Text | Google Scholar

Lee, Y., Watanabe, T. (2022). Bio-electrochemical impedance analysis of frozen japanese pear tissues: and the relationships among the physical properties, total polyphenol content, and oxidase activity. LWT 153, 112499. doi: 10.1016/j.lwt.2021.112499

CrossRef Full Text | Google Scholar

Lee, Y., Watanabe, T., Nakaura, Y., Ando, Y., Nagata, M., Yamamoto, K. (2019). Cultivar differences in electrical and mechanical property changes and tolerance in apples due to high hydrostatic pressure treatment. Postharvest Biol. Technol. 156, 110947. doi: 10.1016/j.postharvbio.2019.110947

CrossRef Full Text | Google Scholar

Li, M., Hu, J., Yang, M., Yang, J., Zhang, Q., Zubarev, Y. A., et al. (2022). Quality attributes and dielectric properties of sea buckthorn berries under differing freezing regimes and their interrelationships. Foods 11 (23), 3825. doi: 10.3390/foods11233825

PubMed Abstract | CrossRef Full Text | Google Scholar

Li, Z., Wang, N., Raghavan, G. V., Vigneault, C. (2009). Ripeness and rot evaluation of ‘tommy atkins’ mango fruit through volatiles detection. J. Food Eng. 91 (2), 319–324. doi: 10.1016/j.jfoodeng.2008.09.009

CrossRef Full Text | Google Scholar

Li, J., Xu, Y., Zhu, W., Wei, X., Sun, H. (2019). Maturity assessment of tomato fruit based on electrical impedance spectroscopy. Int. J. Agric. Biol. Eng. 12 (4), 154–161. doi: 10.25165/j.ijabe.20191204.4664

CrossRef Full Text | Google Scholar

Li, L., Zhang, Q., Huang, D. (2014). A review of imaging techniques for plant phenotyping. Sensors 14 (11), 20078–20111. doi: 10.3390/s141120078

PubMed Abstract | CrossRef Full Text | Google Scholar

Liaghat, S., Mansor, S., Ehsani, R., Shafri, H. Z. M., Meon, S., Sankaran, S. (2014). Mid-infrared spectroscopy for early detection of basal stem rot disease in oil palm. Comput. Electron. Agric. 101, 48–54. doi: 10.1016/j.compag.2013.12.012

CrossRef Full Text | Google Scholar

Lichtenthaler, H. K. (1998). The stress concept in plants: an introduction. Ann. New York Acad. Sci. 851, 187–198. doi: 10.1111/j.1749-6632.1998.tb08993.x

CrossRef Full Text | Google Scholar

Lins, E. C., Belasque, J., Marcassa, L. G. (2009). Detection of citrus canker in citrus plants using laser induced fluorescence spectroscopy. Precis. Agric. 10 (4), 319–330. doi: 10.1007/s11119-009-9124-2

CrossRef Full Text | Google Scholar

Liu, D., Guo, W. (2017). Nondestructive determination of soluble solids content of persimmons by using dielectric spectroscopy. Int. J. Food Properties 20, S2596–S2611. doi: 10.1080/10942912.2017.1381114

CrossRef Full Text | Google Scholar

Liu, Y., Li, D., Qian, J., Di, B., Zhang, G., Ren, Z. (2021a). Electrical impedance spectroscopy (eis) in plant roots research: a review. Plant Methods 17 (1), 1–25. doi: 10.1186/s13007-021-00817-3

PubMed Abstract | CrossRef Full Text | Google Scholar

Liu, J., Wang, X. (2021). Plant diseases and pests detection based on deep learning: a review. Plant Methods 17, 1–18. doi: 10.1186/s13007-021-00722-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Liu, D., Wang, E., Wang, G., Wang, P., Wang, C., Wang, Z. (2021b). Non-destructive sugar content assessment of multiple cultivars of melons by dielectric properties. J. Sci. Food Agric. 20 (20), 4308–4314. doi: 10.1002/jsfa.11070

CrossRef Full Text | Google Scholar

Luna, J. M. M., Luna, A. M., Fernández, R. E. H. (2020). Characterization and differentiation between olive varieties through electrical impedance spectroscopy, neural networks and IoT. Sensors 20 (20), 5932. doi: 10.3390/s20205932

PubMed Abstract | CrossRef Full Text | Google Scholar

Macdonald, J. R. (1992). Impedance spectroscopy. Ann. Biomed. Eng. 22 (24), 289–305. doi: 10.1007/BF02368532

CrossRef Full Text | Google Scholar

MacDonald, J. (2013). LEVM/LEVMW manual - CNLS (Complex nonlinear least squares) immittance, inversion, and simulation fitting programs for WINDOWS and MS-DOS, version 20.09. http://www.jrossmacdonald.com/LEVM/LEVMMANUAL.pdf.

Google Scholar

Macdonald, J. R., Garber, J. (1977). Analysis of impedance and admittance data for solids and liquids. J. Electrochemical Soc. 124 (7), 1022. doi: 10.1149/1.2133473

CrossRef Full Text | Google Scholar

Macdonald, J. R., Schoonman, J., Lehnen, A. (1981). Three dimensional perspective plotting and fitting of immittance data. Solid State Ionics 5, 137–140. doi: 10.1016/0167-2738(81)90211-3

CrossRef Full Text | Google Scholar

Mancuso, S. (1999). Seasonal dynamics of electrical impedance parameters in shoots and leaves related to rooting ability of olive (olea europea) cuttings. Tree Physiol. 19 (2), 95–101. doi: 10.1093/treephys/19.2.95

PubMed Abstract | CrossRef Full Text | Google Scholar

Mancuso, S. (2000). Electrical resistance changes during exposure to low temperature measure chilling and freezing tolerance in olive tree (olea europaea l.) plants. Plant Cell Environ. 23 (3), 291–299. doi: 10.1046/j.1365-3040.2000.00540.x

CrossRef Full Text | Google Scholar

Mancuso, S., Rinaldelli, E. (1996). Response of young mycorrhizal and non-mycorrhizal plants of olive tree (olea europaea l.) to saline conditions. ii. dynamics of electrical impedance parameters of shoots and leaves. Adv. Hortic. Sci., 135–145.

Google Scholar

Marquardt, D. W. (1963). An algorithm for least-squares estimation of nonlinear parameters. J. Soc. Ind. Appl. Mathematics 11 (2), 431–441. doi: 10.1137/0111030

CrossRef Full Text | Google Scholar

Maundy, B. J., Elwakil, A. S., Allagui, A. (2015). Extracting the parameters of the single-dispersion cole bioimpedance model using a magnitude-only method. Comput. Electron. Agric. 119, 153–157. doi: 10.1016/j.compag.2015.10.014

CrossRef Full Text | Google Scholar

Meiqing, L., Jinyang, L., Hanping, M., Yanyou, W. (2016). Diagnosis and detection of phosphorus nutrition level for solanum lycopersicum based on electrical impedance spectroscopy. Biosyst. Eng. 143, 108–118. doi: 10.1016/j.biosystemseng.2016.01.005

CrossRef Full Text | Google Scholar

Meiqing, L., Jinyang, L., Xinhua, W., Wenjing, Z. (2017). Early diagnosis and monitoring of nitrogen nutrition stress in tomato leaves using electrical impedance spectroscopy. Int. J. Agric. Biol. Eng. 10, 194–205. doi: 10.3965/j.ijabe.20171003.3188

CrossRef Full Text | Google Scholar

Mishra, P., Feller, T., Schmuck, M., Nicol, A., Nordon, A. (2019). “Early detection of drought stress in arabidopsis thaliana utilsing a portable hyperspectral imaging setup,” in 2019 10th Workshop on Hyperspectral Imaging and Signal Processing: Evolution in Remote Sensing (WHISPERS). (Amsterdam, Netherlands: IEEE), 1–5.

Google Scholar

Mohammed, M., Munir, M., Aljabr, A. (2022). Prediction of date fruit quality attributes during cold storage based on their electrical properties using artificial neural networks models. Foods 11 (11), 1666. doi: 10.3390/foods11111666

PubMed Abstract | CrossRef Full Text | Google Scholar

Mohanty, S. P., Hughes, D. P., Salathé, M. (2016). Using deep learning for image-based plant disease detection. Front. Plant Sci. 7, 1419. doi: 10.3389/fpls.2016.01419

PubMed Abstract | CrossRef Full Text | Google Scholar

Montero, R., Pérez-Bueno, M. L., Barón, M., Florez-Sarasa, I., Tohge, T., Fernie, A. R., et al. (2016). Alterations in primary and secondary metabolism in vitis vinifera ‘malvasía de banyalbufar’upon infection with grapevine leafroll-associated virus 3. Physiol. Plantarum 157 (4), 442–452. doi: 10.1111/ppl.12440

CrossRef Full Text | Google Scholar

Mousa, M. A., AboBakr, A., Said, L. A., Madian, A. H., Elwakil, A. S., Radwan, A. G. (2019). “Heating and freezing injury to plant tissues and their effect on bioimpedance: experimental study,” in 2019 Fourth International Conference on Advances in Computational Tools for Engineering Applications (ACTEA). (Zouk Mosbeh, Lebanon: IEEE), 1–4. doi: 10.1109/ACTEA.2019.8851098

CrossRef Full Text | Google Scholar

Muñoz-Huerta, R. F., Guevara-Gonzalez, R. G., Contreras-Medina, L. M., Torres-Pacheco, I., Prado-Olivarez, J. (2013). Ocampo-velazquez RV. a review of methods for sensing the nitrogen status in plants: advantages, disadvantages and recent advances. Sensors 13 (8), 10823–10843. doi: 10.3390/s130810823

PubMed Abstract | CrossRef Full Text | Google Scholar

Mur, L. A., Mandon, J., Cristescu, S. M., Harren, F. J., Prats, E. (2011). Methods of nitric oxide detection in plants: a commentary. Plant Sci. 181 (5), 509–519. doi: 10.1016/j.plantsci.2011.04.003

PubMed Abstract | CrossRef Full Text | Google Scholar

Nirmal, M., Jadhav, P., Pawar, S. (2022). Classification of pomegranate leaves diseases by image processing and machine learning techniques. Cybernetics Syst., 1–15. doi: 10.1080/01969722.2022.2145448

CrossRef Full Text | Google Scholar

Nouaze, J. C., Kim, J. H., Jeon, G. R., Kim, J. H. (2022). Monitoring of indoor farming of lettuce leaves for 16 hours using electrical impedance spectroscopy (EIS) and double-shell model (dsm). Sensors 22 (24), 9671. doi: 10.3390/s22249671

PubMed Abstract | CrossRef Full Text | Google Scholar

Nowak, B. (2021). Precision agriculture: where do we stand? a review of the adoption of precision agriculture technologies on field crops farms in developed countries. Agric. Res. 10 (4), 515–522. doi: 10.1007/s40003-021-00539-x

CrossRef Full Text | Google Scholar

Ochandio Fernández, A., Olguín Pinatti, C. A., Masot Peris, R., Laguarda-Miró, N. (2019). Freeze-damage detection in lemons using electrochemical impedance spectroscopy. Sensors 19 (18), 4051. doi: 10.3390/s19184051

PubMed Abstract | CrossRef Full Text | Google Scholar

Okajima, M., Sugiyama, M. (2023). Direct and in situ observations of plants under various light illumination conditions using electrochemical impedance spectroscopy. Japanese J. Appl. Phys. 62 (2), 027002. doi: 10.35848/1347-4065/acb6cb

CrossRef Full Text | Google Scholar

Orazem, M. E., Agarwal, P., Garcia-Rubio, L. H. (1994). Critical issues associated with interpretation of impedance spectra. J. Electroanalytical Chem. 378, 51–62. doi: 10.1016/0022-0728(94)87056-X

CrossRef Full Text | Google Scholar

Orazem, M. E., Tribollet, B. (2008). Electrochemical impedance spectroscopy (Hoboken, New Jersey: John Wiley & Sons).

Google Scholar

Ozier-Lafontaine, H., Bajazet, T. (2005). Analysis of root growth by impedance spectroscopy (EIS). Plant Soil 277 (1), 299–313. doi: 10.1007/s11104-005-7531-3

CrossRef Full Text | Google Scholar

Paglis, C. M. (2013). Application of electrical resistivity tomography for detecting root biomass in coffee trees. Int. J. Geophys. 2013. doi: 10.1155/2013/383261

CrossRef Full Text | Google Scholar

Park, Y., Seol, J., Pak, J., Jo, Y., Jun, J., Son, H. I. (2022). A novel end-effector for a fruit and vegetable harvesting robot: mechanism and field experiment. Precis. Agric. 23, 1–23. doi: 10.1007/s11119-022-09981-5

CrossRef Full Text | Google Scholar

Pérez-Bueno, M. L., Pineda, M., Barón, M. (2019). Phenotyping plant responses to biotic stress by chlorophyll fluorescence imaging. Front. Plant Sci. 10, 1135. doi: 10.3389/fpls.2019.01135

PubMed Abstract | CrossRef Full Text | Google Scholar

Pérez-Bueno, M. L., Pineda, M., Díaz-Casado, E., Barón, M. (2015). Spatial and temporal dynamics of primary and secondary metabolism in phaseolus vulgaris challenged by pseudomonas syringae. Physiol. Plantarum 153 (1), 161–174. doi: 10.1111/ppl.12237

CrossRef Full Text | Google Scholar

Pieters, O., De Swaef, T., Lootens, P., Stock, M., Roldán-Ruiz, I., Wyffels, F.. (2020). Limitations of snapshot hyperspectral cameras to monitor plant response dynamics in stress-free conditions. Comput. Electron. Agric. 179, 105825. doi: 10.1016/j.compag.2020.105825

CrossRef Full Text | Google Scholar

Prasad, A., Roy, M. (2020). Bioimpedance analysis of vascular tissue and fluid flow in human and plant body: a review. Biosyst. Eng. 197, 170–187. doi: 10.1016/j.biosystemseng.2020.06.006

CrossRef Full Text | Google Scholar

Rahaman, M. M., Chen, D., Gillani, Z., Klukas, C., Chen, M. (2015). Advanced phenotyping and phenotype data analysis for the study of plant growth and development. Front. Plant Sci. 6, 619. doi: 10.3389/fpls.2015.00619

PubMed Abstract | CrossRef Full Text | Google Scholar

Ramírez-Chavarría, R. G., Sánchez-Pérez, C., Romero-Ornelas, L., Ramón-Gallegos, E. (2020). Time-constant-domain spectroscopy: an impedance-based method for sensing biological cells in suspension. IEEE Sensors J. 21 (1), 185–192. doi: 10.1109/JSEN.2020.3014569

CrossRef Full Text | Google Scholar

Repo, T., Korhonen, A., Laukkanen, M., Lehto, T., Silvennoinen, R. (2014). Detecting mycorrhizal colonisation in scots pine roots using electrical impedance spectra. Biosyst. Eng. 121, 139–149. doi: 10.1016/j.biosystemseng.2014.02.014

CrossRef Full Text | Google Scholar

Repo, T., Korhonen, A., Lehto, T., Silvennoinen, R. (2016). Assessment of frost damage in mycorrhizal and non-mycorrhizal roots of scots pine seedlings using classification analysis of their electrical impedance spectra. Trees 30 (2), 483–495. doi: 10.1007/s00468-015-1171-x

CrossRef Full Text | Google Scholar

Repo, T., Paine, D., Taylor, A. (2002). Electrical impedance spectroscopy in relation to seed viability and moisture content in snap bean (phaseolus vulgaris l.). Seed Sci. Res. 12 (1), 17–29. doi: 10.1079/SSR200194

CrossRef Full Text | Google Scholar

Repo, T., Zhang, M., Ryyppö, A., Vapaavuori, E., Sutinen, S. (1994). Effects of freeze-thaw injury on parameters of distributed electrical circuits of stems and needles of scots pine seedlings at different stages of acclimation. J. Exp. Bot. 45 (6), 823–833. doi: 10.1093/jxb/45.6.823

CrossRef Full Text | Google Scholar

Reyes, A., Yarlequé, M., Castro, W., Chuquizuta, S. (2018). “Determination of permittivity values using microwave dielectric spectroscopy for assessing apple and purple sweet potato quality parameters,” in 2018 International Conference on Electromagnetics in Advanced Applications (ICEAA). (Cartagena De Indias,Colombia: IEEE), 593–596. doi: 10.1109/ICEAA.2018.8520427

CrossRef Full Text | Google Scholar

Romero Fogué, D., Masot Peris, R., Ibáñez Civera, J., Contat Rodrigo, L., Laguarda-Miro, N. (2022). Monitoring freeze-damage in grapefruit by electric bioimpedance spectroscopy and electric equivalent models. Horticulturae 8 (3), 218. doi: 10.3390/horticulturae8030218

CrossRef Full Text | Google Scholar

Roy, A., Biswas, P., Mallick, A. (2019). “Identification of bioimpedance parameters for characterizing of tissue: a case study with apple tissue by anova,” in 2019 International Conference on Ubiquitous and Emerging Concepts on Sensors and Transducers (UEMCOS). (Kolkata, India: IEEE), Vol. 1. 1–4. doi: 10.1109/UEMCOS46508.2019.9221622

CrossRef Full Text | Google Scholar

Sahrawat, K. L., Chaudhury, S., Srinivasu, K., Wani, S. P. (2016). Comparative evaluation of inductively coupled plasma-optical emission spectrometry and colorimetry for determining phosphorus in grain samples. Commun. Soil Sci. Plant Anal. 47 (7), 818–821. doi: 10.1080/00103624.2016.1146895

CrossRef Full Text | Google Scholar

Sankaran, S., Mishra, A., Maja, J. M., Ehsani, R. (2011). Visible-near infrared spectroscopy for detection of huanglongbing in citrus orchards. Comput. Electron. Agric. 77 (2), 127–134. doi: 10.1016/j.compag.2011.03.004

CrossRef Full Text | Google Scholar

Schubert, T. S., Rizvi, S. A., Sun, X., Gottwald, T. R., Graham, J. H., Dixon, W. N. (2001). Meeting the challenge of eradicating citrus canker in florida–again. Plant Dis. 85 (4), 340–356. doi: 10.1094/PDIS.2001.85.4.340

PubMed Abstract | CrossRef Full Text | Google Scholar

Schwan, H. P. (1957). Electrical properties of tissue and cell suspensions. Adv. Biol. Med. Phys. 5, 147–209. doi: 10.1016/b978-1-4832-3111-2.50008-0

PubMed Abstract | CrossRef Full Text | Google Scholar

Schweidler, E. (1907). Studien über die anomalien im verhalten der dielektrika. Annalen der Physik 329 (14), 711–770. doi: 10.1002/andp.19073291407

CrossRef Full Text | Google Scholar

Serrano-Pallicer, E., Muñoz-Albero, M., Pérez-Fuster, C., Masot Peris, R., Laguarda-Miró, N. (2018). Early detection of freeze damage in navelate oranges with electrochemical impedance spectroscopy. Sensors 18 (12), 4503. doi: 10.3390/s18124503

PubMed Abstract | CrossRef Full Text | Google Scholar

Shi, F., Kolb, J. F. (2020). Enhanced resolution impedimetric analysis of cell responses from the distribution of relaxation times. Biosensors Bioelectronics 157, 112149. doi: 10.1016/j.bios.2020.112149

PubMed Abstract | CrossRef Full Text | Google Scholar

Singh, U. P., Chouhan, S. S., Jain, S., Jain, S. (2019). Multilayer convolution neural network for the classification of mango leaves infected by anthracnose disease. IEEE Access 7, 43721–43729. doi: 10.1109/ACCESS.2019.2907383

CrossRef Full Text | Google Scholar

Srivastava, S., Sadistap, S. (2022). Data fusion for fruit quality authentication: combining non-destructive sensing techniques to predict quality parameters of citrus cultivars. J. Food Measurement Characterization 16 (1), 344–365. doi: 10.1007/s11694-021-01165-5

CrossRef Full Text | Google Scholar

Sugiyama, M., Okajima, M. (2022). Application of electrochemical impedance spectroscopy and modeling of the novel equivalent circuit for monitoring cellular tissues. Theor. Exp. Plant Physiol., 1–8. doi: 10.1007/s40626-022-00260-2

CrossRef Full Text | Google Scholar

Tiitta, M., Tiitta, V., Heikkinen, J., Lappalainen, R., Tomppo, L. (2020). Classification of wood chips using electrical impedance spectroscopy and machine learning. Sensors 20 (4), 1076. doi: 10.3390/s20041076

PubMed Abstract | CrossRef Full Text | Google Scholar

Tm, P., Pranathi, A., SaiAshritha, K., Chittaragi, N. B., Koolagudi, S. G. (2018). “Tomato leaf disease detection using convolutional neural networks,” in 2018 eleventh International Conference on Contemporary Computing (IC3). (Noida, India: IEEE), 1–5. doi: 10.1109/IC3.2018.8530532

CrossRef Full Text | Google Scholar

Tomkiewicz, D., Piskier, T. (2012). A plant based sensing method for nutrition stress monitoring. Precis. Agric. 13 (3), 370–383. doi: 10.1007/s11119-011-9252-3

CrossRef Full Text | Google Scholar

Toyoda, K., Tsenkova, R. (1998). Measurement of freezing process of agricultural products by impedance spectroscopy. IFAC Proc. Volumes 31 (9), 89–94. doi: 10.1016/S1474-6670(17)44035-3

CrossRef Full Text | Google Scholar

Udink ten Cate, A., Bot, G., Van Dixhoorn, J. (1978). “Computer control of greenhouse climates,” in Symposium on Potential Productivity in Protected Cultivation (International Society for Horticultural Science), Vol. 87. 265–272. doi: 10.17660/ActaHortic.1978.87.28

CrossRef Full Text | Google Scholar

Van Haeverbeke, M., Stock, M., De Baets, B. (2021). Practical equivalent electrical circuit identification for electrochemical impedance spectroscopy analysis with gene expression programming. IEEE Trans. Instrumentation Measurement 70, 1–12. doi: 10.1109/TIM.2021.3113116

CrossRef Full Text | Google Scholar

Van Haeverbeke, M., Stock, M., De Baets, B. (2022). Equivalent electrical circuits and their use across electrochemical impedance spectroscopy application domains. IEEE Access 10, 51363–51379. doi: 10.1109/ACCESS.2022.3174067

CrossRef Full Text | Google Scholar

Vanoli, M., Buccheri, M. (2012). Overview of the methods for assessing harvest maturity. Stewart Postharvest Rev. doi: 10.2212/spr.2012.1.4

CrossRef Full Text | Google Scholar

Vastarouchas, C., Psychalinos, C., Elwakil, A., Al-Ali, A. (2019). Novel two-measurements-only cole-cole bio-impedance parameters extraction technique. Measurement 131, 394–399. doi: 10.1016/j.measurement.2018.09.008

CrossRef Full Text | Google Scholar

Vozáry, E., Benko, P. (2010). “Non-destructive determination of impedance spectrum of fruit flesh under the skin,” in Journal of Physics: Conference Series. (San Francisco, USA: IOP Publishing), Vol. 224. 012142. doi: 10.1088/1742-6596/224/1/012142

CrossRef Full Text | Google Scholar

Vozary, E., Jocsak, I., Droppa, M., Boka, K. (2012). “Connection between structural changes and electrical parameters of pea root tissue under anoxia,” in Anoxia. Ed. Padilla, P. (Rijeka: IntechOpen). doi: 10.5772/29589

CrossRef Full Text | Google Scholar

Vozáry, E., Paine, D., Kwiatkowski, J., Taylor, A. (2007). Prediction of soybean and snap bean seed germinability by electrical impedance spectroscopy. Seed Sci. Technol. 35 (1), 48–64. doi: 10.15258/sst.2007.35.1.05

CrossRef Full Text | Google Scholar

Wang, H., Long, X., Sun, Y., Wang, D., Wang, Z., Meng, H., et al. (2022). Electrochemical impedance spectroscopy applied to microbial fuel cells: a review. Front. Microbiol. 13. doi: 10.3389/fmicb.2022.973501

CrossRef Full Text | Google Scholar

Wang, S., Zhang, J., Gharbi, O., Vivier, V., Gao, M., Orazem, M. E. (2021). Electrochemical impedance spectroscopy. Nat. Rev. Methods Primers 70, 1–21. doi: 10.1038/s43586-021-00039-w

CrossRef Full Text | Google Scholar

Wang, Y. Q., Zhao, P. F., Fan, L. F., Zhou, Q., Wang, Z. Y., Song, C., et al. (2019). Determination of water content and characteristic analysis in substrate root zone by electrical impedance spectroscopy. Comput. Electron. Agric. 156, 243–253. doi: 10.1016/j.compag.2018.11.037

CrossRef Full Text | Google Scholar

Watanabe, T., Ando, Y., Orikasa, T., Shiina, T., Kohyama, K. (2017). Effect of short time heating on the mechanical fracture and electrical impedance properties of spinach (spinacia oleracea l.). J. Food Eng. 194, 9–14. doi: 10.1016/j.jfoodeng.2016.09.001

CrossRef Full Text | Google Scholar

Watanabe, T., Nakamura, N., Ando, Y., Kaneta, T., Kitazawa, H., Shiina, T. (2018). Application and simplification of cell-based equivalent circuit model analysis of electrical impedance for assessment of drop shock bruising in japanese pear tissues. Food Bioprocess Technol. 11, 2125–2129. doi: 10.1007/s11947-018-2173-7

CrossRef Full Text | Google Scholar

Weiß, A., Schindler, S., Galbiati, S., Danzer, M. A., Zeis, R. (2017). Distribution of relaxation times analysis of high-temperature pem fuel cell impedance spectra. Electrochim. Acta 230, 391–398. doi: 10.1016/j.electacta.2017.02.011

CrossRef Full Text | Google Scholar

Wold, S., Sjöström, M., Eriksson, L. (2001). Pls-regression: a basic tool of chemometrics. Chemometrics Intelligent Lab. Syst. 58 (2), 109–130. doi: 10.1016/S0169-7439(01)00155-1

CrossRef Full Text | Google Scholar

Wu, L., Ogawa, Y., Tagawa, A. (2008). Electrical impedance spectroscopy analysis of eggplant pulp and effects of drying and freezing–thawing treatments on its impedance characteristics. J. Food Eng. 87 (2), 274–280. doi: 10.1016/j.jfoodeng.2007.12.003

CrossRef Full Text | Google Scholar

Wu, J., Wang, D., Rosen, C. J., Bauer, M. E. (2007). Comparison of petiole nitrate concentrations, spad chlorophyll readings, and quickbird satellite imagery in detecting nitrogen status of potato canopies. Field Crops Res. 101 (1), 96–103. doi: 10.1016/j.fcr.2006.09.014

CrossRef Full Text | Google Scholar

Xing, D., Chen, L., Wu, Y., Zwiazek, J. J. (2021). Leaf physiological impedance and elasticity modulus in orychophragmus violaceus seedlings subjected to repeated osmotic stress. Scientia Hortic. 276, 109763. doi: 10.1016/j.scienta.2020.109763

CrossRef Full Text | Google Scholar

Xu, H., Zhu, S., Ying, Y., Jiang, H. (2006). Early detection of plant disease using infrared thermal imaging. Optics Natural Resources Agriculture Foods (SPIE) 6381, 302–308. doi: 10.1117/12.685534

CrossRef Full Text | Google Scholar

Yousri, D., AbdelAty, A. M., Said, L. A., Elwakil, A. S., Maundy, B., Radwan, A. G. (2019). Chaotic flower pollination and grey wolf algorithms for parameter extraction of bio-impedance models. Appl. Soft Computing 75, 750–774. doi: 10.1016/j.asoc.2018.11.020

CrossRef Full Text | Google Scholar

Yu, L., Dongjian, H., Zhaoyong, Z., Haihui, Z., Dong, S. (2016). Nondestructive detection of apple mouldy core based on bioimpedance properties. J. Agric. Machinery 47 (4), 193–200. doi: 10.7506/spkx1002-6630-201318040

CrossRef Full Text | Google Scholar

Yu, S., Liu, Y., Tang, Y., Li, X., Li, W., Li, C., et al. (2022). Non-destructive quality assessment method for korla fragrant pears based on electrical properties and adaptive neural-fuzzy inference system. Comput. Electron. Agric. 203, 107492. doi: 10.1016/j.compag.2022.107492

CrossRef Full Text | Google Scholar

Yu, S., Sheng, L., Zhang, C., Deng, H. (2018). Physiological response of arundo donax to cadmium stress by fourier transform infrared spectroscopy. Spectrochim. Acta Part A: Mol. Biomolecular Spectrosc. 198, 88–91. doi: 10.1016/j.saa.2018.02.039

CrossRef Full Text | Google Scholar

Yue, X., Hu, Y., Zhang, H., Schmidhalter, U. (2020). Evaluation of both spad reading and spad index on estimating the plant nitrogen status of winter wheat. Int. J. Plant Production 14, 67–75. doi: 10.1007/s42106-019-00068-2

CrossRef Full Text | Google Scholar

Zerbini, P. E. (2006). Emerging technologies for non-destructive quality evaluation of fruit. J. Fruit Ornamental Plant Res. 14, 13–18.

Google Scholar

Zhang, Q., Huang, C. G., Li, H., Feng, G., Peng, W. (2022). Electrochemical impedance spectroscopy based state of health estimation for lithium-ion battery considering temperature and state of charge effect. IEEE Trans. Transportation Electrification 8, 4633–4645. doi: 10.1109/TTE.2022.3160021

CrossRef Full Text | Google Scholar

Zhang, Q., Li, Q., Zhang, G. (2012). Rapid determination of leaf water content using vis/nir spectroscopy analysis with wavelength selection. Spectroscopy: Int. J. 27, 93–105. doi: 10.1155/2012/276795

CrossRef Full Text | Google Scholar

Zhang, M., Stout, D., Willison, J. (1990). Electrical impedance analysis in plant tissues: symplasmic resistance and membrane capacitance in the hayden model. J. Exp. Bot. 41, 371–380. doi: 10.1093/jxb/41.3.371

CrossRef Full Text | Google Scholar

Zhang, M., Willison, J. (1991). Electrical impedance analysis in plant tissues11. J. Exp. Bot. 42 (11), 1465–1475. doi: 10.1093/jxb/42.11.1465

CrossRef Full Text | Google Scholar

Zhang, M., Willison, J. (1992). Electrical impedance analysis in plant tissues: the effect of freeze-thaw injury on the electrical properties of potato tuber and carrot root tissues. Can. J. Plant Sci. 72 (2), 545–553. doi: 10.4141/cjps92-068

CrossRef Full Text | Google Scholar

Zhang, L., Zhou, Z., Chen, Q., Long, R., Quan, S. (2019). Model predictive control for electrochemical impedance spectroscopy measurement of fuel cells based on neural network optimization. IEEE Trans. Transportation Electrification 5 (2), 524–534. doi: 10.1109/TTE.2019.2909687

CrossRef Full Text | Google Scholar

Zoltowski, P. (1984). The error function for fitting of models to immittance data. J. Electroanalytical Chem. Interfacial Clectrochem. 178, 11–19. doi: 10.1016/S0022-0728(84)80019-4

CrossRef Full Text | Google Scholar

Keywords: electrochemical impedance spectroscopy, plant cells, equivalent electrical circuit, plant stress, fruit ripening

Citation: Van Haeverbeke M, De Baets B and Stock M (2023) Plant impedance spectroscopy: a review of modeling approaches and applications. Front. Plant Sci. 14:1187573. doi: 10.3389/fpls.2023.1187573

Received: 16 March 2023; Accepted: 20 June 2023;
Published: 31 July 2023.

Edited by:

Lars Hendrik Wegner, Foshan University, China

Reviewed by:

Uwe Pliquett, Institut für Bioprozess- und Analysenmesstechnik (IBA), Germany
Yosi Shacham, Tel Aviv University, Israel

Copyright © 2023 Van Haeverbeke, De Baets and Stock. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Maxime Van Haeverbeke, maxime.vanhaeverbeke@ugent.be

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.