Skip to main content

ORIGINAL RESEARCH article

Front. Physiol., 19 August 2022
Sec. Exercise Physiology

Effects of footwear with different longitudinal bending stiffness on biomechanical characteristics and muscular mechanics of lower limbs in adolescent runners

  • 1Faculty of Sports Science, Ningbo University, Ningbo, China
  • 2The Affiliated Hospital of Medical School, Ningbo University, Ningbo, China
  • 3Department of Sport Physical Education and Health, Hong Kong Baptist University, Kowloon, Hong Kong SAR, China
  • 4Center for Health and Exercise Science Research, Hong Kong Baptist University, Kowloon, Hong Kong SAR, China

Background: Running shoes with carbon plates have been identified to have positive effects on improving running performance from a biomechanical perspective. However, the specific difference between the effects of carbon plates with different longitudinal bending stiffness (LBS)on biomechanical characteristics and muscular mechanics of lower limbs in adolescent runners remains unclear. This study aimed to identify the difference in biomechanical characteristics and muscular mechanics in lower limbs during running stance phases between wearing shoes with low longitudinal bending stiffness (Llbs) and high longitudinal bending stiffness (Hlbs) carbon plates in adolescent runners.

Methods: 10 male adolescent runners with a habit of daily running exercise (age: 13.5 ± 0.6 years; height: 166.3 ± 1.9 cm; bodyweight: 50.8 ± 3.1 kg; foot length: 25.4 ± 0.2 cm) were recruited and asked to conduct two times of tests by wearing shoes with Llbs and Hlbs carbon plates in a randomized order. Paired t-test and statistical parametric mapping (SPM) analysis were used to identify the difference in biomechanical characteristics and muscular mechanics in lower limbs during running stance phases.

Result: Under the condition of wearing shoes with Hlbs, the time of foot contact significantly increased, whereas the range of motion (ROM) of hip and metatarsophalangeal (MTP) in the sagittal plane significantly reduced as well as the peak moment of ankle joint in the sagittal plane. The activations of vastus medialis, vastus lateralis, flexor digitorum brevis (flex dig brevis), and flexor hallucis longus (flex hall long) significantly increased under the condition of wearing shoes with Hlbs. According to the results of the SPM analysis, the joint angles (hip, ankle, and MTP), the net joint moments (knee, ankle, and MTP), and the muscle forces (gluteus maximus and tibialis anterior) were significant difference during the running stance phase between conditions of wearing shoes with Hlbs and Llbs.

Conclusion: Running shoes with Llb carbon plates are appropriate for adolescent runners due to the advantages of biomechanical characteristics and muscular mechanics.

Introduction

Running, which is a flexible and practical exercise with freedom in time and place, has gradually become one of the most popular leisure sports with an accumulating amount of youthful participants due to its benefit for health (Baranowski et al., 1997). Within the development of running shoes, the role of carbon plates embedded in the button of running shoes are becoming increasingly important. Moreover, because of the potential in providing positive effects on performance during the ground contact phases of walking, running, and jumping, the longitudinal bending stiffness (LBS) of the carbon plates in shoes has attracted considerable attention from biomechanics researchers in recent decades (Flores et al., 2019).

Previous studies have demonstrated that a larger LBS of shoes could improve the performance of vertical jumping and sprinting as well as optimize the energy efficiency of running (Stefanyshyn and Nigg, 2000; Stefanyshyn and Fusco, 2004; Roy and Stefanyshyn, 2006). Since many previous studies found that the increased LBS could reduce the dorsiflexion of the metatarsophalangeal joint (MTP) as well as the ground reaction forces (GRFs) for propulsion, the mechanism of running energy efficiency optimization might be that the reduction of oxygen consumption during running-induced by the biomechanical advantages from the increased LBS (Madden et al., 2016; Hoogkamer et al., 2019; Jiang 2020). For example, Roy and Stefanyshyn (2006) reported that the increased LBS resulted in the increased peak ankle joint moment. Ortega’s study published in 2021 claimed that the MTP and ankle joint mechanics were primarily affected by LBS, which had little effect on knee and hip joint mechanics (Ortega et al., 2021). At the same time, as the LBS increased, in the sagittal plane, the center of GRFs moved forward and the moment arm of GRFs of lower limb joints increased (Willwacher et al., 2014; Madden et al., 2016; Moore et al., 2016; Flores et al., 2017). A systematic review and meta-analysis conducted by Rodrigo-Carranza’s team in 2021 identified that, in comparison to normal shoes, it would take more force generated by muscle to bent shoes with a high longitudinal bending stiffness (Hlbs). Besides, this review also claimed that individuals tend to increase their plantar ankle flexion moments and muscle contractions to overcome mechanical disadvantage caused by the prolonged foot contact and propulsive phases induced by the LBS increase (Rodrigo-Carranza et al., 2021). A study conducted by Cigoja’s team in 2020 also found that, when compared to the participants who wore normal shoes in the control group, the participants who wore Hlbs shoes in the experimental group had a lower shortening rate of calf triceps tendons. They inferred that to generate equivalent muscular force under a slower shortening rate of muscle fiber, fewer motor units were recruited. By this mechanism, the metabolic expenditure during running was cut since the muscular power output had become more economical (Cigoja et al., 2020). In addition, other kinematic and kinetic data have been shown to correlate with energy expenditure while running (Hoogkamer et al., 2018). According to the present evidence, the higher LBS of the shoe could indicate a better running economy. A study by Roy and Stefanyshyn (2006) examined the running economy (RE) when wearing shoes of three different LBS conditions and found that being compared to wearing normal shoes, the RE of runners would increase by 0.8 percent when wearing shoes with Llbs carbon plates. In contrast, the increase of RE when wearing shoes with Hlbs carbon plates seemed not statistically significant when being compared to that of wearing normal shoes.

Previous studies have verified that different mechanical characteristics of the muscle-tendon complex in lower limbs could affect the performance, energy expenditure, and biomechanical characteristics of running (Beltran, 2021). For example, generally speaking, males have stiffer muscle-tendon complexes in lower limbs than females (Kong and De Heer, 2008). Concerning the effect of such physiological differences on lower limb biomechanics, some previous studies have revealed the gender difference in lower limb biomechanical characteristics in runners wearing shoes with different LBS (Micheli et al., 2013). However, most previous studies focused on the biomechanical characteristics and muscular mechanics of adult runners or physiological parameters of adolescent runners, for instance, in 1989, Nudel’s team found that the factors affecting the running performance of adolescents were related to blood lactic acid level, bone maturity, and body coordination under the influence of maximal oxygen uptake (Nudel et al., 1989). In 2021, Xu’s team found that the body of adolescents is undergoing growth and maturing such as the longitudinal growth that occurs in the articular cartilage and epiphysis and axial isotope growth in the thickening and broadening of long bones (Xu et al., 2021), few studies focus on the biomechanical characteristics and muscular mechanics of lower limbs in adolescent runners.

Unsimilar to adult runners whose musculoskeletal systems are more balance within bones, muscles, and soft tissues and hamstrings and quadriceps usually contain more muscle fibers, adolescents, whose bone expansion would possibly outpace the muscle synthesis and tendon lengthening, are easy to get a “mismatch” in their musculoskeletal systems because of their rapid body growth (Kong and De Heer, 2008). Moreover, adolescent runners have lower muscle strength than adults but often have more joint mobilities and tendon flexibilities (Micheli et al., 2013). Therefore, research focusing on the biomechanical characteristics and muscular mechanics of lower limbs in adolescent runners would provide a significant contribution to the field.

This study aimed to identify the difference in biomechanical characteristics and muscular mechanics in lower limbs during running stance phases between wearing shoes with Llbs and Hlbs carbon plates in adolescent runners based on the following hypotheses. First, the range of motion (ROM) of the MTP will reduce when wearing shoes with Hlbs whereas the peak moment of the ankle will increase. Second, during the running stance phases, the peak muscle force generated when wearing shoes with Llbs carbon plates will be smaller than that generated when wearing shoes with Hlbs carbon plates. Last, during the running stance phases, the impulsion loaded on lower limbs when wearing shoes with Hlbs will be larger than that loaded when wearing shoes with Llbs.

Materials and methods

Participants

10 adolescent runners, who have a habit of running exercise (more than 16 km of running exercise in 1 week, more than 70 km of running training in the last month, and have been receiving any form of aerobic training over the previous 2 years) were recruited (Pereles et al., 2012). The volunteers, who had no lower limbs musculoskeletal injury history during the past 2 months and with shoe size at 41 in European size, right leg as the dominant leg, and heel-grounding running, were screened out as the participants in this trial. The mean age of the eligible participants was 13.5 ± 0.6 years old, the mean body height was 166.3 ± 1.9 cm, the mean body weight was 50.8 ± 3.1 kg, and the mean foot length was 25.4 ± 0.2 cm. All participants obtained and signed written consent forms approved by the Institutional Review Board before the test.

Experimental procedures

The information on running shoes that were used in the test is shown in Table 1. The specific LSB values were 5.0 Nm/rad (Llbs shoes) and 8.6 Nm/rad (Hlbs shoes); the difference in LBS between Hlbs shoes and Llbs shoes was that a 1 mm carbon plate is added to Llbs shoes, while a 1.5 mm carbon plate is added to Hlbs shoes; the rest of the shoe was the same. Shoe longitudinal bending stiffness was tested using a 3-point bending protocol (Roy and Stefanyshyn, 2006). All tests were conducted in the laboratory of biomechanics. The kinematic data were collected using a VICON MX motion analysis system (Oxford Metrics Ltd., Oxford, United Kingdom), which consisted of eight cameras and sampled at a rate of 200 Hz. The dynamics data were collected at a sampling rate of 1,000 Hz using a 600 mm × 400 mm force platform (AMTI, Watertown, MA, United States). Synchronization of the kinematic and kinetic data was performed. Reflective markers were placed following the gait 2392 marker set (Kim et al., 2018). Each participant was fitted with thirty-nine (12.5 mm in diameter) reflective markers. Referring to previous research methods and good wrapping of shoes, foot markers were placed on the shoe (Cigoja et al., 2019). Figure 1 outlines the placement of each marker.

TABLE 1
www.frontiersin.org

TABLE 1. List of experimental running shoes.

FIGURE 1
www.frontiersin.org

FIGURE 1. Illustration of the placements of the marker on three different sides.

Procedure

Each participant was required to complete a warm-up session including one set of 10-min running on a treadmill at 8 km/h and one series of lower-body stretches (Zhou et al., 2021). All participants were allowed three trials to familiarize themselves with the test maneuvers before the formal test. In the first step of the formal test, each participant was asked to stand on a force platform to collect static coordinates by standing parallel to the Y-axis of the force platform with arms crossed over shoulders and eyes looking forward until the full static coordinates were captured. Then, each participant performed running tasks along 10 m sidewalks at a speed of 3.3 m/s with 1minunte interval rest for kinematic and kinetic data collection (Isherwood et al., 2021). After obtaining 5 times trials with eligible data on the dominant leg, in which the running speed of the participant was less than 5% variance and within 5% of the predefined running speed. The definition of the initial contact was the moment when the ground reaction force exceeded 10 N (Jiang et al., 2021).

Data process and analysis

The kinematic data and ground reaction force were identified and collected by the Vicon Nexus 1.8.6 software and exported as c3d format files. MATLAB R2016b (The MathWorks, Natick, MA, United States) was used for coordinate system transformation, low-pass filtering, data extraction, and format conversion of kinematic data and ground reaction force data. The process of data analysis was as followed: 1) Convert the coordinate system of the kinematic data and ground reaction force data to the coordinate system used in subsequent simulations. The forward direction of the human body was defined as the positive direction of the X-axis, and the upward direction perpendicular to the ground was the Y-axis. The positive direction and the right direction of the human body were the positive directions of the Z-axis. 2) Biomechanical data of marker trajectories and ground reaction forces filtered with 6 and 30 Hz fourth-order zero-phase lag Butterworth low-pass filters. 3) Extract the kinematic and ground reaction force data of running stance phases and convert the data format to track (Marker track) and mot. (Force plate data) format required by OpenSim simulation software. OpenSim (Stanford University, Stanford University, CA, United States) was used to process and calculate biomechanical parameters in our research. The musculoskeletal model from OpenSim (gait 2392) was used, which had ten rigid bodies, 23 degrees of freedom, and 92 tendon actuators (Delp et al., 1990; Delp et al., 2007). In the following steps, lower limb joint angles, joint moments in the sagittal plane, and muscle force were outputted.

Step 1: Import the statics model into the OpenSim 4.2 software. Then use the scale tool to obtain the anthropometric model of each participant. Identify the muscle starting and ending points, and ensure the moment arms were consistent with the length of the participants’ limb (Delp et al., 2007). Step 2: Use the inverse kinematics (IK) tool in the OpenSim 4.2 software to calculate the joint ROM during the running stance phases and create a motion file (mot). Simultaneously, use the inverse dynamics tool to import the running marker files and external force files into OpenSim and then calculate the joint moments of all the participants. Step 3: Using a static optimization tool with the kinematic data calculated and motion file, calculate the muscle force (Delp et al., 1990). Joint moments and muscle forces were normalized to body weight.

Statistical analysis

The statistical calculations were carried out using SPSS version 25.0 software (IBM, Armonk, NY, United States). Paired t-tests were used to identify the difference in kinematic and kinetic parameters in lower limbs during running stance phases between wearing shoes with Llbs and Hlbs carbon plates. A Holm-Bonferroni correction was implemented to account for multiple t-tests. The criterion of statistical signification was set at 0.05.

The kinematic and kinetic data characteristics were one-dimensional and time-varying (Jiang et al., 2021). Paired t-test was applied to compare mean joint angles, moments, and muscle forces during the running stance phases by using one-dimensional statistical parametric mapping (SPM1d), which relied on random vector field theory to account for data variability (Pataky et al., 2017). The statistical analyses were conducted in MATLAB R2016b (The MathWorks, Natick, MA, United States) with the criterion of statistical signification was 0.05. A Holm-Bonferroni correction was implemented to account for multiple t-tests.

Results

The contact time increased under the Hlbs condition with a statistical significance (p = 0.046); the ROM of the sagittal plane hip angle and MTP joint angle reduced under the Hlbs condition with a statistical significance (p = 0.004 and p = 0.026); the peak moment of the sagittal plane ankle moment reduced under the Hlbs condition with a statistical significance (p = 0.043). (Table 2).

TABLE 2
www.frontiersin.org

TABLE 2. Average contact time, ROM, and peak moment of lower limb joints during stance phase in the Llbs and the Hlbs shoes (mean ± SD).

The flexion angle of the hip in the sagittal plane under the Hlbs condition reduced significantly during the 13.3%–20%, 32.2%–51.1%, and 54.4%–56.7% of the stance phase (p < 0.001) (Figure 2). The extension moment of the knee in the sagittal plane under the Hlbs condition reduced significantly during the 51.1%–53.3% of the stance phase (p < 0.001) (Figure 3). The dorsiflexion angle of the ankle in the sagittal plane under the Hlbs condition increased significantly during the 10.0%–46.7% of the stance phase (p < 0.001); the plantarflexion moment of the ankle in the sagittal plane under the Hlbs condition increased significantly during the 71.1%–73.3% of the stance phase (p = 0.001) (Figures 2,3). The dorsiflexion angle of the MTP joint in the sagittal plane under the Hlbs condition reduced significantly during the 93.3% and 95.6% of the stance phase (p = 0.001); the dorsiflexion moment of the MTP joint in the sagittal plane under the Hlbs condition reduced significantly during 35.6%–38.9% of the stance phase (p < 0.001) (Figures 2,3).

FIGURE 2
www.frontiersin.org

FIGURE 2. Lower limb joint angle waveforms of mean and standard deviation over the stance phase of two shoe conditions. Significant differences (p < 0.05) are highlighted (grey horizontal bars at the bottom of the figure) during corresponding periods from SPM1d analyses.

FIGURE 3
www.frontiersin.org

FIGURE 3. Lower limb joint moment waveforms of mean and standard deviation over the stance phase of two shoe conditions. Significant differences (p < 0.05) are highlighted (grey horizontal bars at the bottom of the figure) during corresponding periods from SPM1d analyses.

There was no significant difference in peak muscle force during stance phase in the Llbs and the Hlbs shoes (Table 3). The impulse of vastus medialis, vastus lateralis, flexor digitorum brevis (flex dig brevis)), and flexor hallucis longus (flex hall long) under the Hlbs condition increased significantly (p = 0.013, p = 0.018, p = 0.001, and p = 0.016) (Table 4). The muscle force of the gluteus maximus2 (gluteus max2) under the Hlbs condition increased significantly during the 21.1% and 25.6% of the stance phase (p < 0.001) (Figure 4); the muscle force of the tibialis anterior under the Hlbs condition increased significantly during the 82.2%–93.3% of the stance phase (p < 0.001) (Figure 4).

FIGURE 4
www.frontiersin.org

FIGURE 4. Lower limb muscle force waveforms of mean and standard deviation over the stance phase of two shoe conditions. Significant differences (p < 0.05) are highlighted (grey horizontal bars at the bottom of the figure) during corresponding periods from SPM1d analyses.

TABLE 3
www.frontiersin.org

TABLE 3. Peak muscle force during stance phase in the Llbs and the Hlbs shoes (mean ± SD).

TABLE 4
www.frontiersin.org

TABLE 4. Impulse during stance phase in the Llbs and the Hlbs shoes (mean ± SD).

Discussion

The objective of this study was to identify the difference in biomechanical characteristics and muscular mechanics in lower limbs during running stance phases between wearing shoes with Llbs and Hlbs carbon plates in adolescent runners. It is found that the ROM of the hip and MTP, the peak moment of the ankle reduced when wearing shoes with the Hlbs, and the impulse of vastus medialis, vastus lateralis, flex dig brevis, and flex hall long increased when wearing shoes with the Hlbs. When wearing shoes with the Hlbs, the flexion angle of the hip reduced during the 13.3%–20%, 32.2%–51.1%, and 54.4%–56.7% of the stance phase, and the dorsiflexion angle of the ankle increased during the 10.0%–46.7% of the stance phase, and the muscle force of tibialis anterior increased during the 82.2%–93.3% of the stance phase.

Considering the musculoskeletal development of adolescents, in this trial, the running shoes for tests with different LBS were chosen according to the running shoes for adult runners. The existing running shoes on the market such as Nike Zoom Streak 6 and Adidas adizero Adios BOOST 2 have an LBS from 9.4 Nm/rad to 7.0 Nm/rad respectively (Hoogkamer et al., 2019). Day and Hahn defined 10 Nm/rad as the threshold of stiffness in the allocation of experimental groups with different LBS as variate in their trial that explored the optimal LBS to improve running economy (Day and Hahn, 2020). According to this information, 8.6 Nm/rad was chosen as the threshold of stiffness in the allocation of Hlb-Group, whereas the LBS gradient was set based on the data of the previous study by Ortega’s team. The shoes used in Llb-Group were adjusted by changing the thickness of the carbon plate (Ortega et al., 2021).

Previous studies have demonstrated that the increasing LBS could not affect the hip angle, angular velocity, or moment of the participants. (Hoogkamer et al., 2019; Xu et al., 2022), which is inconsistent with the results of this study. According to the results of this study, it is suggested that the ROM of the hip joint would reduce under the Hlbs conditions. Moreover, the results of time-series analyses revealed that adolescent runners would show smaller initial hip angles and larger initial ankle angles in the sagittal plane under the Hlbs condition. Besides, the decrease in the ROM of the hip joint under the Hlbs condition might be induced by the underdeveloped musculoskeletal muscles of adolescents as well as their immature motor control system. The potential mechanism might be that the decreased ROM of the hip joint when wearing shoes with a carbon plate of Hlbs could compensate for the change in the angle of the knee and ankle joints. The neural adjustment ability of the teenagers’ body which could make a timely adjustment before landing is weaker than that of adults. Therefore, in this study, adolescent runners showed smaller initial hip angles and larger initial ankle angles in the sagittal plane. Many previous studies have discovered a similar phenomenon in which the increasing LBS stiffened the MTP joint, limited dorsiflexion, and slowed the angular velocity of dorsiflexion (Willwacher et al., 2013; Oh and Park, 2017; Hoogkamer et al., 2019; Xiang et al., 2022), being consistent with the findings in this study, which claimed that shoes with carbon plates of Hlbs could reduce the ROM of the MTP joint.

As mentioned above, a previous study by Roy and Stefanyshyn (2006) reported that the peak ankle moment would increase with a larger LBS during running on a treadmill with an inclination of 1%. However, some other previous studies found that there would be neither difference in the peak ankle moment or average ankle moment (Wannop et al., 2017; Beck et al., 2020). In addition, a study by Willwacher et al. (2014) published in 2014 demonstrated that running on shoes with moderate stiffness could have a lower mean ankle moment than running on control shoes (Llbs). The result of this study presented a decrease in the peak moment of the ankle joint under the Hlbs condition. Since the results of the time-series analyses revealed an increase in muscle force of the tibialis anterior muscle during the propulsive phase under the Hlbs condition and an unchanged force of plantar flexors, the reduced ankle moment was likely the consequence of the tibialis anterior forces increase. It also means that there was a greater co-contraction around the ankle, which is possibly induced by the necessity to transmit a higher amount of force generated by the increased stiffness. The cushioning effect of the shoes is mainly presented in the runner’s heel, since when the overall LBS of the shoes increased, the cushioning effect on the heel faded, and then the impact on the lower limb increased. The lower limb of an adolescent runner has an immature musculoskeletal ability for his or her self-protection. Therefore, adolescent runners tend to go through the braking phase faster and then enter the propulsive phase. In this way, under the Hlbs condition, the timing of the moment production in the hip, knee, and ankle occurred earlier, whereas that in the MTP joint had no changes. The reason might be that the running skill used was a rearfoot grounding which had little effect on the MTP during the breaking phase. This study also found that the impulse of vastus medialis, vastus lateralis, flex dig brevis, and flex hall long increased in the stance phase under the Hlbs condition. It was consistent with the hypothesis of the study that sufficient moment could not be generated to overcome the biomechanical disadvantages induced by the Hlbs carbon plate, making the contact time and impulse increase.

To sum up, it could conclude that when adolescents are running on shoes with Hlbs carbon plates, they were more likely to adopt biomechanical strategies to reduce ankle moment and contact time fhe compensation for ROM loss in their hip joints. Otherwise, the runner’s ankle plantarflexion muscle must generate more force during the stance phases to compensate for the reduced ankle moment under the Hlbs condition. Simultaneously, as the results that running on shoes with Hlbs carbon plates could increase muscle impulse by increasing the contact time, and the immature of the lower limb musculoskeletal development in adolescents, the plantarflexion muscle strength and impulse would be generated continuously when running, bringing their musculoskeletal system higher to load and increasing the risk of muscle strain and achillodynia (Best, 1993; Sancho et al., 2019). It is indicated that running shoes with Llb carbon plates would be more appropriate for young runners.

There were some limitations in this study. First, the participants of this study were all male adolescent runners. Some previous studies have demonstrated that female runners might have different biomechanical characteristics such as the different pelvic structures. Second, there were only two kinds of stiffness analyzed in this study. Further studies should explore running on shoes with carbon plates in different stiffness gradients to identify the most suitable LBS for adolescent runners.

Conclusion

In conclusion, this study investigated the effects of different LBS shoe conditions on adolescent runners’ lower limb biomechanics and muscle mechanics. Low longitudinal bending stiffness shoes are appropriate for young runners due to musculoskeletal developmental characteristics. Further research should focus on setting multiple stiffness gradients to explore the optimal range of LBS for adolescent runners.

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding authors.

Ethics statement

The studies involving human participants were reviewed and approved by the Research academy of grand health. The patients/participants provided their written informed consent to participate in this study.

Author contributions

HC, ES, and DS conceived the presented idea, developed the framework, and wrote the manuscript. RX, JB, and YG provided critical feedback and contributed to the final version. All authors were involved in the final direction of the paper and contributed to the final version of the manuscript. All authors have read and agreed to the published version of the manuscript.

Funding

This study is supported by Zhejiang Province Medical and Health Science and Technology Plan Project (No. 2018KY710), Ningbo Public Welfare Science and Technology Plan Project (No. 2019C50095), Health Youth Technical Talent Cultivation Special Fund Project (2020SWSQNGG-01), Ningbo Medical Science and Technology Plan (2020Y14), Young Cultivation Fund Project of The Affiliated of School of Medicine of Ningbo University (FYQM-KY-202003), Key R&D Program of Zhejiang Province China (2021C03130), and Zhejiang Province Science Fund for Distinguished Young Scholars (R22A021199).

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

Baranowski T., Bar-Or O., Blair S., Corbin C., Dowda M., Freedson P., et al. (1997). Guidelines for school and community programs to promote lifelong physical activity among young people. Morb. Mortal. Wkly. Rep. 50 (RR-6), 1–36.

PubMed Abstract | CrossRef Full Text | Google Scholar

Beck O. N., Golyski P. R., Sawicki G. S. (2020). Adding carbon fiber to shoe soles may not improve running economy: A muscle-level explanation. Sci. Rep. 10 (1), 17154. doi:10.1038/s41598-020-74097-7

PubMed Abstract | CrossRef Full Text | Google Scholar

Beltran R. T. (2021). The influence of footwear longitudinal bending stiffness on running economy and biomechanics in older runners. Memphis: The University of Memphis.

Google Scholar

Best T. M. (1993). A biomechanical study of skeletal muscle strain injuries. Durham: Duke University.

Google Scholar

Cigoja S., Asmussen M. J., Firminger C. R., Fletcher J. R., Edwards W. B., Nigg B. M., et al. (2020). The effects of increased midsole bending stiffness of sport shoes on muscle-tendon unit shortening and shortening velocity: A randomised crossover trial in recreational male runners. Sports Med. Open 6 (1), 9. doi:10.1186/s40798-020-0241-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Cigoja S., Firminger C. R., Asmussen M. J., Fletcher J. R., Edwards W. B., Nigg B. M., et al. (2019). Does increased midsole bending stiffness of sport shoes redistribute lower limb joint work during running? J. Sci. Med. Sport 22 (11), 1272–1277. doi:10.1016/j.jsams.2019.06.015

PubMed Abstract | CrossRef Full Text | Google Scholar

Day E., Hahn M. (2020). Optimal footwear longitudinal bending stiffness to improve running economy is speed dependent. Footwear Sci. 12 (1), 3–13. doi:10.1080/19424280.2019.1696897

CrossRef Full Text | Google Scholar

Delp S. L., Anderson F. C., Arnold A. S., Loan P., Habib A., John C. T., et al. (2007). OpenSim: Open-source software to create and analyze dynamic simulations of movement. IEEE Trans. Biomed. Eng. 54 (11), 1940–1950. doi:10.1109/TBME.2007.901024

PubMed Abstract | CrossRef Full Text | Google Scholar

Delp S. L., Loan J. P., Hoy M. G., Zajac F. E., Topp E. L., Rosen J. M., et al. (1990). An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures. IEEE Trans. Biomed. Eng. 37 (8), 757–767. doi:10.1109/10.102791

PubMed Abstract | CrossRef Full Text | Google Scholar

Flores N., Delattre N., Berton E., Rao G. (2017). Effects of shoe energy return and bending stiffness on running economy and kinetics. Footwear Sci. 9 (Suppl. 1), S11–S13. doi:10.1080/19424280.2017.1313894

CrossRef Full Text | Google Scholar

Flores N., Rao G., Berton E., Delattre N. (2019). The stiff plate location into the shoe influences the running biomechanics. Sports Biomech. 20 (7), 815–830. doi:10.1080/14763141.2019.1607541

PubMed Abstract | CrossRef Full Text | Google Scholar

Hoogkamer W., Kipp S., Frank J. H., Farina E. M., Luo G., Kram R., et al. (2018). A comparison of the energetic cost of running in marathon racing shoes. Sports Med. 48 (4), 1009–1019. doi:10.1007/s40279-017-0811-2

PubMed Abstract | CrossRef Full Text | Google Scholar

Hoogkamer W., Kipp S., Kram R. (2019). The biomechanics of competitive male runners in three marathon racing shoes: A randomized crossover study. Sports Med. 49 (1), 133–143. doi:10.1007/s40279-018-1024-z

PubMed Abstract | CrossRef Full Text | Google Scholar

Isherwood J., Wang H., Sterzing T. (2021). Running biomechanics and running shoe perception of Chinese men and women. Footwear Sci. 13 (1), 55–67. doi:10.1080/19424280.2020.1853827

CrossRef Full Text | Google Scholar

Jiang C. (2020). The effect of basketball shoe collar on ankle stability: A systematic review and meta-analysis. Phys. Activity Health 4 (1), 11–18. doi:10.5334/paah.48

CrossRef Full Text | Google Scholar

Jiang X., Yang X., Zhou H., Baker J. S., Gu Y. (2021). Prolonged running using bionic footwear influences lower limb biomechanics. Healthcare 9 (2), 236. doi:10.3390/healthcare9020236

PubMed Abstract | CrossRef Full Text | Google Scholar

Kim Y., Jung Y., Choi W., Lee K., Koo S. (2018). Similarities and differences between musculoskeletal simulations of OpenSim and AnyBody modeling system. J. Mech. Sci. Technol. 32 (12), 6037–6044. doi:10.1007/s12206-018-1154-0

CrossRef Full Text | Google Scholar

Kong P. W., De Heer H. (2008). Anthropometric, gait and strength characteristics of Kenyan distance runners. J. Sports Sci. Med. 7 (4), 499–504.

PubMed Abstract | Google Scholar

Madden R., Sakaguchi M., Tomaras E. K., Wannop J. W., Stefanyshyn D. (2016). Forefoot bending stiffness, running economy and kinematics during overground running. Footwear Sci. 8 (2), 91–98. doi:10.1080/19424280.2015.1130754

CrossRef Full Text | Google Scholar

Micheli L. J., Bachl N., Chan K.-M., Pigozzi F., Frontera W. R. (2013). Team physician manual: International federation of sports medicine (FIMS). Abingdon: Routledge.

Google Scholar

Moore I. S., Jones A. M., Dixon S. (2016). Reduced oxygen cost of running is related to alignment of the resultant grf and leg axis vector: A pilot study. Scand. J. Med. Sci. Sports 26 (7), 809–815. doi:10.1111/sms.12514

PubMed Abstract | CrossRef Full Text | Google Scholar

Nudel D. B., Hassett I., Gurian A., Diamant S., Weinhouse E., Gootman N. (1989). Young long distance runners: Physiological and psychological characteristics. Clin. Pediatr. 28 (11), 500–505. doi:10.1177/000992288902801103

PubMed Abstract | CrossRef Full Text | Google Scholar

Oh K., Park S. (2017). The bending stiffness of shoes is beneficial to running energetics if it does not disturb the natural MTP joint flexion. J. Biomech. 53 (1), 127–135. doi:10.1016/j.jbiomech.2017.01.014

PubMed Abstract | CrossRef Full Text | Google Scholar

Ortega J. A., Healey L. A., Swinnen W., Hoogkamer W. (2021). Energetics and biomechanics of running footwear with increased longitudinal bending stiffness: A narrative review. Sports Med. 51 (5), 873–894. doi:10.1007/s40279-020-01406-5

PubMed Abstract | CrossRef Full Text | Google Scholar

Pataky T. C., Vanrenterghem J., Robinson M. (2017). Statistical parametric mapping (spm): Theory, software and future directions. Brisbane, Australia: Proceedings of the International Society of Biomechanics, 23–27.

Google Scholar

Pereles D., Roth A., Thompson D. (20122011). A large, randomized, prospective study of the impact of a pre-run stretch on the risk of injury in teenage and older runners. USATF. Org. 15.

Google Scholar

Rodrigo-Carranza V., González-Mohíno F., Santos-Concejero J., González-Ravé J. M. (2021). The effects of footwear midsole longitudinal bending stiffness on running economy and ground contact biomechanics: A systematic review and meta-analysis. Eur. J. Sport Sci. 1 (1), 1–14. doi:10.1080/17461391.2021.1955014

CrossRef Full Text | Google Scholar

Roy J.-P. R., Stefanyshyn D. J. (2006). Shoe midsole longitudinal bending stiffness and running economy, joint energy, and EMG. Med. Sci. Sports Exerc. 38 (3), 562–569. doi:10.1249/01.mss.0000193562.22001.e8

PubMed Abstract | CrossRef Full Text | Google Scholar

Sancho I., Malliaras P., Barton C., Willy R. W., Morrissey D. (2019). Biomechanical alterations in individuals with achilles tendinopathy during running and hopping: A systematic review with meta-analysis. Gait Posture 73 (1), 189–201. doi:10.1016/j.gaitpost.2019.07.121

PubMed Abstract | CrossRef Full Text | Google Scholar

Stefanyshyn D., Fusco C. (2004). Athletics: Increased shoe bending stiffness increases sprint performance. Sports Biomech. 3 (1), 55–66. doi:10.1080/14763140408522830

PubMed Abstract | CrossRef Full Text | Google Scholar

Stefanyshyn D. J., Nigg B. M. (2000). Influence of midsole bending stiffness on joint energy and jump height performance. Med. Sci. Sports Exerc. 32 (2), 471–476. doi:10.1097/00005768-200002000-00032

PubMed Abstract | CrossRef Full Text | Google Scholar

Wannop J. W., Killick A., Madden R., Stefanyshyn D. J. (2017). The influence of gearing footwear on running biomechanics. Footwear Sci. 9 (2), 111–119. doi:10.1080/19424280.2017.1342705

CrossRef Full Text | Google Scholar

Willwacher S., König M., Braunstein B., Goldmann J.-P., Brüggemann G.-P. (2014). The gearing function of running shoe longitudinal bending stiffness. Gait Posture 40 (3), 386–390. doi:10.1016/j.gaitpost.2014.05.005

PubMed Abstract | CrossRef Full Text | Google Scholar

Willwacher S., König M., Potthast W., Brüggemann G.-P. (2013). Does specific footwear facilitate energy storage and return at the metatarsophalangeal joint in running? J. Appl. Biomech. 29 (5), 583–592. doi:10.1123/jab.29.5.583

PubMed Abstract | CrossRef Full Text | Google Scholar

Xiang L., Mei Q., Wang A., Shim V., Fernandez J., Gu Y., et al. (2022). Evaluating function in the hallux valgus foot following a 12-week minimalist footwear intervention: A pilot computational analysis. J. Biomech. 132, 110941. doi:10.1016/j.jbiomech.2022.110941

PubMed Abstract | CrossRef Full Text | Google Scholar

Xu D., Quan W., Zhou H., Sun D., Baker J. S., Gu Y., et al. (2022). Explaining the differences of gait patterns between high and low-mileage runners with machine learning. Sci. Rep. 22 (121), 2981. doi:10.1038/s41598-022-07054-1

CrossRef Full Text | Google Scholar

Xu G., Liu H., Zhang L., Xie S., Deng K., Zhao C. (2021). Influence of taekwondo competition on cortical thickness in the calcaneus and stress distribution in the trabecular bone. Chin. J. Tissue Eng. Res. 25 (35), 5582.

Google Scholar

Zhou H., Xu D., Quan W., Liang M., Ugbolue U. C., Baker J. S., et al. (2021). A pilot study of muscle force between normal shoes and bionic shoes during men walking and running stance phase using opensim. Actuators 10 (10), 274. doi:10.3390/act10100274

CrossRef Full Text | Google Scholar

Keywords: running shoes, longitudinal bending stiffness (LBS), adolescents, lower limb biomechanics, muscle mechanics

Citation: Chen H, Shao E, Sun D, Xuan R, Baker JS and Gu Y (2022) Effects of footwear with different longitudinal bending stiffness on biomechanical characteristics and muscular mechanics of lower limbs in adolescent runners. Front. Physiol. 13:907016. doi: 10.3389/fphys.2022.907016

Received: 29 March 2022; Accepted: 01 July 2022;
Published: 19 August 2022.

Edited by:

Alexandre Fouré, Université de Lyon, France

Reviewed by:

Juha Hijmans, University Medical Center Groningen, Netherlands
Fernando González-Mohíno, University of Castilla-La Mancha, Spain

Copyright © 2022 Chen, Shao, Sun, Xuan, Baker and Gu. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Rongrong Xuan, fyxuanrongrong@nbu.edu.cn; Yaodong Gu, guyaodong@nbu.edu.cn

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.