AUTHOR=Avignone III Frank T. , Elliott Steven R. TITLE=The Search for Double Beta Decay With Germanium Detectors: Past, Present, and Future JOURNAL=Frontiers in Physics VOLUME=7 YEAR=2019 URL=https://www.frontiersin.org/journals/physics/articles/10.3389/fphy.2019.00006 DOI=10.3389/fphy.2019.00006 ISSN=2296-424X ABSTRACT=
High Purity Germanium Detectors have excellent energy resolution; the best among the technologies used in double beta decay. Since neutrino-less double beta decay hinges on the search for a rare peak upon a background continuum, this strength has enabled the technology to consistently provide leading results. The Ge crystals at the heart of these experiments are very pure; they have no measurable U or Th contamination. The added efforts to reduce the background associated with electronics, cryogenic cooling, and shielding have been very successful, leading to the longevity of productivity. The first experiment published in 1967 by the Milan group of Fiorini, established the benchmark half-life limit >3 × 1020 yr. This bound was improved with the early work of the USC-PNNL, UCSB, and Milan groups yielding limits above 1023 yr. The Heidelberg-Moscow and USC-PNNL collaborations pioneered the use of enriched Ge for detector fabrication. Both groups also initiated techniques of analyzing pulse waveforms to reject γ-ray background. These steps extended the limits to just over 1025 yr. In 2000, a subset of the Heidelberg-Moscow collaboration claimed the observation of double beta decay. More recently, the