Skip to main content

ORIGINAL RESEARCH article

Front. Oncol., 28 June 2023
Sec. Radiation Oncology

The impact of bone marrow sparing on organs at risk dose for cervical cancer: a Pareto front analysis

Sander Kuipers,*Sander Kuipers1,2*Jrmy Godart,Jérémy Godart1,2Anouk CorbeauAnouk Corbeau3Abdul Wahab SharfoAbdul Wahab Sharfo1Sebastiaan BreedveldSebastiaan Breedveld1Jan Willem MensJan Willem Mens1Stephanie de BoerStephanie de Boer3Remi NoutRemi Nout1Mischa Hoogeman,Mischa Hoogeman1,2
  • 1Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, Netherlands
  • 2Department of Medical Physics and Informatics, HollandPTC, Delft, Netherlands
  • 3Department of Radiation Oncology, Leiden University Medical Center, Leiden, Netherlands

Background and purpose: To quantify the increase in bladder and rectum dose of a bone marrow sparing (BMS) VMAT strategy for primary treatment of locally advanced cervical cancer (LACC).

Materials and methods: Twenty patients with stage IB-IVA cervical cancer were selected for this study. The whole Pelvic Bones (PB) was taken as substitute for bone marrow. For every patient, Pareto-optimal plans were generated to explore the trade-off between rectum, bladder, and PB mean dose. The PB mean dose was decreased in steps of 1 Gy. For each step, the increase in rectum and bladder mean dose was quantified. The increase in mean dose of other OAR compared to no BMS was constrained to 1 Gy.

Results: In total, 931 plans of 19 evaluable patients were analyzed. The average [range] mean dose of PB without BMS was 22.8 [20.7-26.2] Gy. When maximum BMS was applied, the average reduction in mean PB dose was 5.4 [3.0-6.8] Gy resulting in an average mean PB dose of 17.5 [15.8-19.8] Gy. For <1 Gy increase in both the bladder and the rectum mean dose, the PB mean dose could be decreased by >2 Gy, >3 Gy, >4 Gy, and >5 Gy for 19/19, 13/19, 5/19, and 1/19 patients, respectively.

Conclusion: Based on the comprehensive three-dimensional Pareto front analysis, we conclude that 2-5 Gy BMS can be implemented without a clinically relevant increase in mean dose to other OAR. If BMS is too dominant, it results in a large increase in mean dose to other OAR. Therefore, we recommend implementing moderate BMS for the treatment of LACC patients with VMAT.

Introduction

The standard treatment for locally advanced cervical cancer is a combination of external beam radiotherapy (RT) with concurrent cisplatin-based chemotherapy and image-guided brachytherapy (1). This treatment provides high local and pelvic tumor control and cancer-specific survival (2, 3). However, this combination of treatment modalities is associated with a substantial risk of developing hematologic toxicities (HT) grade 2 or higher, e.g. leukopenia and neutropenia (4). In a recent study by Huang et al., the incidence of HT2+ was 69.5% with the standard treatment of locally advanced cervical cancer (LACC) (5) and in the INTERTECC-2 study by Mell et al., the incidence of HT3+ was 31.4% (6). HT can necessitate blood transfusions and lead to an increased risk of infection, missed chemotherapy cycles, or an extension of the treatment time (7, 8). Furthermore, radiation-induced lymphopenia may be associated with lower overall survival (9).

The high incidence of HT is associated with the radiation dose to the pelvic bones and lower spine, in which a large amount of hematopoietically active bone marrow cells are located (10). The irradiation of circulating blood cells in that region might also cause HT (11). Several studies investigated predictors of HT during treatment for LACC, as analyzed in recent reviews (4, 12). Both low and high doses to the pelvic bones were shown to be important in the risk of developing HT (5, 1315). The evidence from earlier research also suggests that the incidence of HT can be reduced if bone marrow sparing (BMS) is introduced during treatment plan optimization (5, 6, 12, 16). However, the risk of implementing BMS is that it leads to an increase of the dose to other areas of the pelvic region, possibly in organs at risk (OAR) such as the bladder, rectum, and small bowel. A higher dose to these OAR could increase the risk of gastrointestinal and genitourinary toxicities (GI/GU), which are two of the most frequently reported morbidities related to this treatment (2), and could have a clear impact on quality of life (17).

Several treatment planning studies have assessed the impact of BMS (12). A significant increase in GI and GU toxicity grade 2+ as a result of implementing BMS has not been observed (5). However, most studies considered IMRT and did not use the EMBRACE II planning constraints, resulting in a large variation in applied constraints and, consequently, in results (18). Furthermore, all earlier studies have evaluated only a fixed degree of BMS, instead of the full large range of BMS. Therefore, the maximum degree of BMS that can be achieved without clinically significant dose increases for other OARs using VMAT with EMBRACE II planning constraints has not been established.

The aim of this study was to systematically evaluate the trade-off between BMS and dose increases for other OAR for VMAT using the EMBRACE II protocol. To this end, we used automated treatment planning to create three-dimensional Pareto fronts for the mean dose of the bladder, rectum, and pelvic bones. Based on these fronts, we determined the maximum degree of BMS possible without clinically significant dose increases for the other OARs.

Methods

Patient data

LACC patients treated at Erasmus MC between December 2019 and January 2021 according to the EMBRACE II protocol were selected for this study (18). All patients underwent an empty and a full-bladder planning CT scan with 2.5 mm slice thickness in a supine position prior to treatment. The minimal field of view of the scans was from 5 cm inferior of the ischial tuberosities to the L1 vertebra. All patients received drinking instructions prior to the full-bladder planning CT (19).

Normal tissue delineation

All OAR were delineated on the full-bladder planning CT following the EMBRACE II protocol (18). The delineated OAR included the bladder, rectum, sigmoid, bowel bag, femoral heads, and spinal cord. Depending on the level of the target volume, the kidneys, liver, and duodenum were also delineated. The rectum was outlined from 2 cm of the anal canal inferiorly to the recto-sigmoid junction superiorly. The bowel bag (outer extension) was delineated superiorly 2 cm above the planning target volume (PTV). In addition, for this study, the outer contour of the pelvic bones (PB) was taken as a substitute for the bone marrow. PB defined as the outer contour was shown to be most predictive of HT (4). The pelvic bones were delineated from the inferior level of the ischial tuberosities to 2 cm superior to the PTV (20). This includes the femoral heads. Superiorly, the border of the delineation is usually at the L4 for medium-risk patients and at the L1 for high-risk patients. The delineation of the pelvic bones are done by SK (20). All other contours were delineated by radiation oncologists during the regular clinical workflow at the Erasmus MC. All contours were checked afterwards (SK, RN) and, when necessary, adapted to ensure consistency.

Target delineation

The low-risk Clinical Target Volume (CTV-LR) included the uterus, cervix, gross tumor, parametria, and proximal vagina with 2 cm margin from the GTV. For patients with a uterus movement of >2 cm between the full and empty-bladder CT scans, a plan-of-the-day strategy was applied with a full and an empty-bladder plan (21). In this study, we only considered the full-bladder plan for movers, for which the internal target volume (ITV) was constructed by encompassing the CTV-LR of the half-full bladder to full bladder (22). This CTV-LR for the half-full bladder was created by interpolation between the CTV-LR on the full-bladder CT scan and the CTV-LR on the empty-bladder CT scan. The ITV of non-movers, i.e., a uterus movement of <2 cm, encompassed the CTV-LR position from empty to full bladder and was uniformly expanded with a 0.5 cm margin.

The risk-adapted Clinical Target Volume (CTV-E) consisted of the relevant lymph nodes regions as described in the EMBRACE II protocol (18). The Planning Target Volume (PTV) was constructed by combining the CTV-E and ITV and uniformly expanding this volume by 0.5 cm. The nodal planning target volumes (PTV-N) were constructed following the EMBRACE II protocol (18).

Pareto-optimal planning

For treatment planning, Erasmus-iCycle was used, our in-house developed algorithm for fully automated multi-criteria treatment plan generation (23). The plans that are generated using this treatment planning system are Pareto optimal (23). This indicates that an objective for such a plan cannot be improved without deteriorating another objective. Examples of such objectives are sufficient target coverage or a low OAR dose. The prescribed dose was 42.75 Gy to 95% of the PTV volume in 25 fractions. The PTV-N received with a simultaneous integrated boost a prescribed dose of 55.0 or 57.5 Gy, depending on the dose that the PTV-N receives during brachytherapy. The plans were created by following the dose constraints of the EMBRACE II protocol (18).

For each patient, a three-dimensional (3D) Pareto front between the rectum, bladder, and PB mean dose was built. A Pareto front is a set of Pareto-optimal plans. In this study, the 3D Pareto front of a patient consisted of four to eight two-dimensional (2D) Pareto fronts showing a trade-off between the bladder and rectum dose. The PB mean dose is constant for each 2D Pareto front. In the representation, these 2D fronts can be thought of as isolines for the PB mean dose. The number of 2D fronts depends on the maximally reachable BMS. Each 2D front consisted of seven Pareto-optimal plans. To build the front for a patient, a reference plan was created without BMS by not using a constraint or objective for the PB in the optimization of the treatment plan. The mean dose of the sigmoid, bowel, kidneys, and duodenum in the following Pareto-optimal plans was constrained to a maximum increase of 1 Gy compared to the reference plan. The first 2D front of a patient had the same mean PB dose as the reference plan, corresponding to 0 Gy BMS, and for each consecutive seven plans for that patient, we decreased the mean PB dose in steps of 1 Gy until the maximum BMS was reached. This is done by making the PB the second most important objective in the wish-list, after the target objective, and decreasing the goal of the objective in steps of 1 Gy. The wish-list used in Erasmus-iCycle is shown and more extensively discussed in Supplementary Materials.

For each Pareto front, the mean dose of the PB, bladder, and rectum was compared. These bladder and rectum mean doses were chosen as endpoints because of their anatomical location and relevance regarding treatment-related morbidity (3). For the whole bone, the V10Gy, V20Gy, V40Gy, and the mean dose were chosen as predictors for hematologic toxicity (4).

Our in-house treatment planning system Erasmus-iCycle uses a fluence-based optimization. Furthermore, 20-beams intensity-modulated radiotherapy (IMRT) planning was used to simulate a VMAT planning (24, 25). The beam arrangement consisted of 20 equiangular beams spanning from 0° to 342°. The plans were made for a 6MV flattening beam. To validate the effect of segmentation and the possibility to simulate VMAT with 20-beams IMRT, 5 treatment plans were replanned for 3 patients (15 in total) with a clinical version of the treatment planning system Eclipse (v. 17.0.0). These three patients were randomly chosen from the patients without simultaneous integrated boosts (SIB), as simulating the VMAT plan in Eclipse was only validated in our clinic for patients with one prescribed dose level. Double-arc plans were created with two 358° coplanar arcs. The dose calculation was performed with the Acuros 17.01 algorithm and the optimization with the PO 17.0.1 algorithm. The method of this validation is further discussed in the Supplementary Materials.

Statistical analysis

The 3D Pareto front of each patient consisted of a set of 2D fronts. Each 2D front showed the trade-off between the bladder and rectum mean dose for a constant PB mean dose. In Figure 1, an example of a 3D Pareto front with two 2D fronts, both consisting of seven plans, is shown. To quantify the increase in bladder and rectum dose when decreasing the PB mean dose, we selected one point on each 2D fronts. This point is representative for an equal weight between the bladder and rectum. Next, the difference in dose between these points was calculated for evaluation. For defining the points on the 2D fronts, we fitted each front with the function DBla(DRec)=αDRec+β, where DBla and DRec are the bladder and rectum mean dose and α and β are the fit parameters for the front. Next, the point is defined as the coordinate where the slope is equal to -1, such that the bladder and rectum are equally weighted. The difference in bladder mean dose ΔDBla and rectum mean dose ΔDRec was then quantified by the difference between these points. In Figure 1, the 2D fronts are fitted and the coordinate on both fronts with a slope of -1 is shown.

FIGURE 1
www.frontiersin.org

Figure 1 An example of a three-dimensional Pareto front, consisting of two two-dimensional Pareto fronts. The two-dimensional Pareto fronts both consist of seven Pareto-optimal plans and show a trade-off between the bladder and rectum mean dose. The two fronts are fitted and the coordinates where the slope of the fit is equal to -1 is indicated with an asterisk. The tangents of these coordinates, which have a slope of -1, are also shown. The horizontal double arrow shows the difference in bladder mean dose ΔDBla between these two coordinates.

The Pareto front for each patient consisted of four to eight 2D fronts. The increase for all patients of the bladder and rectum mean dose as a function of the BMS was fitted for multilevel analysis with an exponential mixed-effects regression model. The accurateness of this model is described by the mean-squared error and the log-likelihood.

Statistical analysis was conducted to assess the organ-at-risk (OAR) using various parameters. For the body, we analyzed the V10Gy. For the bladder, bowel, rectum, and sigmoid, we examined the V30Gy and V40Gy. Additionally, the V15Gy was analyzed for the bowel, the Dmean for the kidneys, and the maximum dose (Dmax) for the spinal cord. Regarding the target coverage, we performed statistical analysis for PTV D95%, D50%, and D0.1%. Conformality was evaluated for V36Gy and V43Gy, with conformality defined as the ratio of V36Gy or V43Gy of the body to the volume of the PTV. All statistical analysis were conducted at 1, 2, and 3 Gy BMS in reference to 0 Gy BMS with the paired t-test at significance levels p ≤. 05 and p ≤. 001. All statistical analyses were performed in Matlab 2012b.

Results

Twenty patients with FIGO 2018 stage IB-IVA cervical cancer were selected for this study. The mean age was 49 years (range 30 - 77). 15/20 patients received simultaneous integrated boost (SIB) to pelvic lymph nodes and in 2/20 patients were identified as high-risk patients and had the paraaortic region included in the CTV-E. The other patients were all medium-risk patients.

For the twenty patients, we generated in total 987 plans. Of the cohort, 19 of the 20 patients were evaluable for analysis, which corresponds to 931 Pareto-optimal plans. One patient was excluded because of the bladder volume having a large overlap with the PTV (104/118 cc) on the full-bladder CT scan, making it impossible to spare the bladder without deteriorating target coverage. In Supplementary Figure S3, the plans with no BMS are shown for all twenty patients and the Pareto front for the excluded patient is shown in cyan. After optimization, all treatment plans satisfied the constraints of the EMBRACE II protocol, however, after calculating the dose grid at CT resolution from the optimization grid, 842/931 (90.4%) satisfied the constraints (18). When the Dmax and Dmin were based on D99.8% and D0.2% instead of D99.9% and D0.1%, 931/931 (100%) plans satisfy the constraints. The average conformality for the 36 Gy volume, defined as V36Gy/Volume of PTV, is 1.50 ± 0.06 and for the 43 Gy volume is 1.07 ± 0.02.

Figure 2 shows the full three-dimensional Pareto front of patient 17. The relatively large reduction in bone marrow dose for this patient helps to visualize the impact of BMS. For this patient, the mean PB dose could be reduced by up to 6.6 Gy, from 24.6 Gy to 18.0 Gy. The reduction of the PB dose and the impact of the dose on the other OAR is visualized in the DVH in Figure 3 for four different plans. The corresponding dose distributions are shown in Figure 4. The dose reduction in the PB is clearly visible while the dose increase in the other OAR only starts to be evident at 6 Gy BMS.

FIGURE 2
www.frontiersin.org

Figure 2 The three-dimensional Pareto front for one patient. The Pareto front consists of 56 Pareto-optimal plans. 0 Gy sparing corresponds to a mean whole bone dose of 24.6 Gy and 6.6 Gy is the maximum BMS. The plans shown in Figure 3 are indicated with a plus-sign.

FIGURE 3
www.frontiersin.org

Figure 3 Dose volume histogram of the PTV, PTV-N1, pelvic bones, bladder, rectum, sigmoid and bowel for 0, 2, 4, and 6 Gy bone marrow sparing for one patient.

FIGURE 4
www.frontiersin.org

Figure 4 Dose distribution for one patient for 0, 2, 4, and 6 Gy bone marrow sparing (BMS). The contour of the pelvic bones is shown in pink.

The average [range] mean dose in the PB for all 19 patients with no BMS was 22.8 [20.7 - 26.2] Gy. When maximum BMS was applied, the average reduction in mean PB dose was 5.4 [3.0-6.8] Gy resulting in a mean PB dose of 17.5 [15.8-19.8] Gy. The average PB V10Gy, V20Gy, and V40Gy are shown in Supplementary Table S2 for 0, 1, 2, and 3 Gy BMS. The conformality index and different dosimetric parameters for OAR and the target coverage are shown in Supplementary Table S3 for 0, 1, 2, and 3 Gy BMS.

Figure 5 shows the increase in the bladder ΔDBla(BMS) and rectum mean dose ΔDRec(BMS) for each patient as a function of the bone marrow sparing BMS. Patients 4 and 7 are the patients with the paraaortic region included. If <1 Gy increase in both the bladder and rectum mean dose is chosen as a clinically acceptable increase, the PB mean dose could be decreased by >1 Gy, >2 Gy, >3 Gy, >4 Gy, and >5 Gy for 19/19, 19/19, 13/19, 5/19, and 1/19 patients, respectively.

FIGURE 5
www.frontiersin.org

Figure 5 The increase in bladder (left bar) and rectum (right bar) mean dose for implementing 1,2, 3, 4, 5, or 6 Gy BMS for each patient.

The increase in bladder and rectum mean dose as a function of BMS is shown in Figure 6. Each black line represents a different patient. All patients show a superlinear increase which can be fitted by an exponential function. The fits of an exponential multilevel analysis are indicated with a red line. The fits are given by DiBla(BMS)=0.062*(exp[0.395*BMS]1)and DiRec(BMS)=0.074*(exp[0.381*BMS]1) with a mean-squared error of 0.0030 and 0.0011 and a log-likelihood of 100.4 and 144.5, respectively.

FIGURE 6
www.frontiersin.org

Figure 6 A visualization of the exponential multilevel analysis. Each blue line corresponds to one patient and shows the average increase in bladder (left) or rectum (right) mean dose as a function of the bone marrow sparing.

In Supplementary Figure S1, the dose volume histogram for one patient is shown for 0 and 3 Gy BMS for the Erasmus-iCycle and the segmented VMAT plans. In Supplementary Figure S2, the increase in bladder and rectum dose as a function of BMS of the segmented VMAT plans is shown and compared to the corresponding Erasmus-iCycle plans. All segmented plans that were constructed using the clinical treatment planning system Eclipse, fulfil the EMBRACE II constraints and have an adequate target coverage. The plans show a superlinear increase similar to the Erasmus-iCycle plans without impacting the target coverage and the clinical constraints.

Discussion

The purpose of this study was to analyze the relation between pelvic bones, bladder, and rectum dose for constant target coverage. This study indicates that the dose to the bladder and rectum increases superlinearly when the pelvic bones dose decreases. Moderate BMS results in a small increase in bladder and rectum dose. It also showed that the PB dose could be reduced further for some patients, but at some point, BMS leads to a substantial increase in dose to the bladder and rectum. It depends on the patient anatomy what a reasonable level of BMS is. These results were obtained after a systematic analysis using automatic planning (Erasmus-iCycle) and were validated in a clinical planning system (Eclipse).

Reducing the PB dose is important as it has been reported that hematologic toxicity is associated with the dose to the PB (911). Besides HT, reducing the dose to PB may decrease the risk of (insufficiency) fractures, which is another frequently reported toxicity after pelvic radiotherapy (26). The dosimetric cut-off values for PB to reduce HT imposed by earlier literature are V10Gy < 75-95% (13, 20, 27), V20Gy < 65-80% (13, 2830), and V40Gy < 28-37% (5, 15). The V10Gy greatly benefits from BMS as the constraint V10Gy < 75% was only accomplished in 2/133 (1.5%) patients for the no-BMS plans and 84/133 (63.1%) for the 3 Gy BMS plans. The constraint V20Gy < 65% is reached in 126/133 (94.7%) plans with no BMS and in all plans for ≥1 Gy BMS. The high dose constraint V40Gy < 28% is already achieved by all no-BMS plans. However, it is unclear if these proposed constraints could be further improved, thus benefits in further reducing the dose can be expected.

The results of this study indicate moreover that BMS planning techniques should be implemented with care. The sparing of the bone marrow is shown to result in a large increase of the bladder and/or rectum dose in case the BMS is too dominant in the chosen planning strategy. For some patients, 5 Gy BMS increases both the bladder and rectum mean dose with more than 4 Gy. The clinical impact of this change in bladder, rectum, and whole bone dose on GI, GU, and hematologic toxicity is however not well known. Further research must be done on identifying the toxicity effect of dosimetric changes in the OAR, to find the optimal balance between OAR sparing during the treatment planning process.

Another interesting result of this study is that the volume of the body exposed to 10 Gy (body V10Gy) decreases significantly when BMS is implemented. For 3 Gy BMS the body V10Gy decreases by 537 cc in comparison to no BMS. The volume of the body exposed to radiation was also shown to be significantly correlated with HT (31). Furthermore, our findings indicate that the high-risk patients show a larger potential for benefiting in BMS. Figure 5 illustrates that patient 4 and 7, classified as high-risk, demonstrate relatively large maximum BMS for a small increase in OAR dose. However, due to the limited number of patients included in this study, an analysis on the Pareto fronts for different classifications could not be conducted. Future studies with larger patient cohorts may provide further insights in this regard.

Based on the results of this study, we advocate the inclusion of PB as an OAR in clinical routine for (VMAT) treatment planning of cervical cancer, but the weight of the PB planning objective should be kept relatively low in comparison to the objectives of other OAR. The precise method to do this differs per treatment planning system. With the use of a low weight for PB sparing, the initial no-BMS plan does not have to be generated to create a baseline in PB mean dose, as was done for this study, and the mean dose of the rectum and bladder does not increase substantially. The outcomes of the validation of the Pareto fronts, discussed in the Supplementary Materials, show that these findings can be reproduced with a clinical treatment planning system and are feasible in the clinic. We foresee no reasons why the results for other tumor sites in the pelvic region would be substantially different. This is therefore a broad recommendation applicable to VMAT treatments of pelvic tumor sites with a high incidence of HT.

Several treatment planning studies have compared no-BMS with BMS plans, however, most studies considered IMRT and there is a large variation in the planning dose constraints and the results. Furthermore, all earlier studies have taken only a fixed degree of BMS into account, whereas, with the Pareto front analysis, we were able to show the dosimetric impact on the rectum and bladder for multiple degrees of BMS with a very small to no change in the target coverage and still fulfilling the planning constraints of the EMBRACE II protocol.

This study demonstrates the advantage of using a systematic approach to introduce a new OAR in a clinical treatment planning strategy. With this meticulous methodology, the effect of different degrees of sparing a new OAR can be quantified. To the best of our knowledge, the present study is the first to investigate the introduction of a new OAR with this methodology. This study shows that Pareto front analysis is an interesting method to determine which objectives should be used in the clinic. While we investigated Pareto fronts for the sparing of the PB for the treatment of cervical cancer with VMAT, the technique is also applicable for other tumor sites, OAR, and treatment modalities. With the same methodology of BMS, future studies can investigate the possibilities of BMS for proton therapy (32).

Conclusion

Based on a comprehensive Pareto front analysis, we conclude that it is possible to decrease the pelvic bones mean dose by 2-5 Gy without increasing the dose to other OAR with a clinically relevant amount (>1 Gy) and that the dose to the bladder and rectum increases superlinearly when decreasing the bone marrow dose. Excessive BMS could however result in large increases in OAR dose. Therefore, we recommend implementing moderate bone marrow sparing for VMAT treatment planning of patients with LACC.

Data availability statement

The datasets presented in this article are not readily available because ethical and privacy restrictions. Requests to access the datasets should be directed to Sander Kuipers, s.c.kuipers@erasmusmc.nl.

Ethics statement

The studies involving human participants were reviewed and approved by Institutional Review Board of the Erasmus University Medical Center Rotterdam. The patients/participants provided their written informed consent to participate in this study.

Author contributions

JG, MH, SdB and RN contributed to the original design of the study. JM and JG supervised the data acquisition. SK, AS and SB built the model. SK did the statistical analysis. JG, SK, AC, SdB, RN and MH contributed to the final design of the study. SK wrote the first draft of the article. All authors contributed to manuscript revision. All authors contributed to the article and approved the submitted version.

Funding

This research was funded by a research grant of Varian Medical Systems Inc, Palo Alto, CA, USA, grant number 2019008.

Conflict of interest

RN reports to have received research grants from Dutch Cancer Society, Dutch Research Council, Elekta, Varian Medical Systems, and Accuray, and a research grant for this work by Varian Medical Systems. MH reports to have received research grants from Varian Medical Systems and Dutch Cancer Society and clinical advisory membership of Accuray. JG reports to have received a research grant for this work by Varian Medical Systems. SdB reports to have received a research grant for this work by Varian Medical Systems.

The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

This study received funding from Varian Medical Systems. The funder was not involved in the study design, collection, analysis, interpretation of data, the writing of this article or the decision to submit it for publication.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fonc.2023.1138433/full#supplementary-material

References

1. Cibula D, Pötter R, Planchamp F, Avall-Lundqvist E, Fischerova D, Haie-Meder C, et al. The European society of gynaecological Oncology/European society for radiotherapy and Oncology/European society of pathology guidelines for the management of patients with cervical cancer. Virchows Archiv (2018) 472(6):919–36. doi: 10.1007/s00428-018-2362-9

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Horeweg N, Creutzberg CL, Rijkmans EC, Laman MS, Velema LA, Coen VLMA, et al. Efficacy and toxicity of chemoradiation with image-guided adaptive brachytherapy for locally advanced cervical cancer. Int J Gynecol Cancer (2019) 29(2). doi: 10.1136/ijgc-2018-000057

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Pötter R, Tanderup K, Schmid MP, Jürgenliemk-Schulz I, Haie-Meder C, Fokdal LU, et al. MRI-Guided adaptive brachytherapy in locally advanced cervical cancer (EMBRACE-i): a multicentre prospective cohort study. Lancet Oncol (2021) 22(4):538–47. doi: 10.1016/S1470-2045(20)30753-1

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Corbeau A, Kuipers SC, de Boer SM, Horeweg N, Hoogeman MS, Godart J, et al. Correlations between bone marrow radiation dose and hematologic toxicity in locally advanced cervical cancer patients receiving chemoradiation with cisplatin: a systematic review. Radiother Oncol (2021) 164:128–37. doi: 10.1016/j.radonc.2021.09.009

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Huang J, Gu F, Ji T, Zhao J, Li G. Pelvic bone marrow sparing intensity modulated radiotherapy reduces the incidence of the hematologic toxicity of patients with cervical cancer receiving concurrent chemoradiotherapy: a single-center prospective randomized controlled trial. Radiat Oncol (2020) 15(1). doi: 10.1186/s13014-020-01606-3

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Mell LK, Sirák I, Wei L, Tarnawski R, Mahantshetty U, Yashar CM, et al. Bone marrow-sparing intensity modulated radiation therapy with concurrent cisplatin for stage IB-IVA cervical cancer: an international multicenter phase II clinical trial (INTERTECC-2). Int J Radiat Oncol Biol Phys (2017) 97(3):536–45. doi: 10.1016/j.ijrobp.2016.11.027

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Abu-Rustum NR, Lee S, Correa A, Massad LS. Compliance with and acute hematologic toxic effects of chemoradiation in indigent women with cervical cancer. Gynecol Oncol (2001) 81(1):88–91. doi: 10.1006/gyno.2000.6109

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Sood BM, Timmins PF, Gorla GR, Garg M, Anderson PS, Vikram B, et al. Concomitant cisplatin and extended field radiation therapy in patients with cervical and endometrial cancer. Int J Gynecol Cancer (2002) 12(5). doi: 10.1046/j.1525-1438.2002.01172.x

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Damen PJJ, Kroese TE, van Hillegersberg R, Schuit E, Peters M, Verhoeff JJC, et al. The influence of severe radiation-induced lymphopenia on overall survival in solid tumors: a systematic review and meta-analysis. Int J Radiat Oncol Biol Phys (2021) 111(4):936–48. doi: 10.1016/j.ijrobp.2021.07.1695

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Ellis RE. The distribution of active bone marrow in the adult. Phys Med Biol (1961) 5(3):255. doi: 10.1088/0031-9155/5/3/302

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Mauch P, Constine L, Greenberger J, Knospe W, Sullivan J, Liesveld JL, et al. Hematopoietic stem cell compartment: acute and late effects of radiation therapy and chemotherapy. Int J Radiat Oncol Biol Phys (1995) 31(5):1319–39. doi: 10.1016/0360-3016(94)00430-S

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Zhou P, Zhang Y, Luo S, Zhang S. Pelvic bone marrow sparing radiotherapy for cervical cancer: a systematic review and meta-analysis. Radiother Oncol (2021) 165:103–18. doi: 10.1016/j.radonc.2021.10.015

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Rose BS, Aydogan B, Liang Y, Yeginer M, Hasselle MD, Dandekar V, et al. Normal tissue complication probability modeling of acute hematologic toxicity in cervical cancer patients treated with chemoradiotherapy. Int J Radiat Oncol Biol Phys (2011) 79(3):800–7. doi: 10.1016/j.ijrobp.2009.11.010

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Chang Y, Yang ZY, Li GL, Li Q, Yang Q, Fan JQ, et al. Correlations between radiation dose in bone marrow and hematological toxicity in patients with cervical cancer: a comparison of 3DCRT, IMRT, and RapidARC. Int J Gynecol Cancer (2016) 26(4):770–6. doi: 10.1097/IGC.0000000000000660

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Klopp AH, Moughan J, Portelance L, Miller BE, Salehpour MR, Hildebrandt E, et al. Hematologic toxicity in RTOG 0418: a phase 2 study of postoperative IMRT for gynecologic cancer. Int J Radiat Oncol Biol Phys (2013) 86(1):83–90. doi: 10.1016/j.ijrobp.2013.01.017

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Song WY, Huh SN, Liang Y, White G, Nichols RC, Watkins WT, et al. Dosimetric comparison study between intensity modulated radiation therapy and three-dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer. J Appl Clin Med Phys (2010) 11(4):83–92. doi: 10.1120/jacmp.v11i4.3255

CrossRef Full Text | Google Scholar

17. Spampinato S, Tanderup K, Lindegaard JC, Schmid MP, Sturdza A, Segedin B, et al. Association of persistent morbidity after radiotherapy with quality of life in locally advanced cervical cancer survivors. Radiother Oncol (2023) 181:109501. doi: 10.1016/j.radonc.2023.109501

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Pötter R, Tanderup K, Kirisits C, de Leeuw A, Kirchheiner K, Nout R, et al. The EMBRACE II study: the outcome and prospect of two decades of evolution within the GEC-ESTRO GYN working group and the EMBRACE studies. Clin Trans Radiat Oncol (2018) 9:48–60. doi: 10.1016/j.ctro.2018.01.001

CrossRef Full Text | Google Scholar

19. Heijkoop ST, Langerak TR, Quint S, Mens JWM, Zolnay AG, Heijmen BJM, et al. Quantification of intra-fraction changes during radiotherapy of cervical cancer assessed with pre-and post-fraction cone beam CT scans. Radiother Oncol (2015) 117(3):536–41. doi: 10.1016/j.radonc.2015.08.034

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Mell LK, Kochanski JD, Roeske JC, Haslam JJ, Mehta N, Yamada SD, et al. Dosimetric predictors of acute hematologic toxicity in cervical cancer patients treated with concurrent cisplatin and intensity-modulated pelvic radiotherapy. Int J Radiat Oncol Biol Phys (2006) 66(5):1356–65. doi: 10.1016/j.ijrobp.2006.03.018

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Heijkoop ST, Langerak TR, Quint S, Bondar L, Mens JWM, Heijmen BJM, et al. Clinical implementation of an online adaptive plan-of-the-day protocol for nonrigid motion management in locally advanced cervical cancer IMRT. Int J Radiat Oncol Biol Phys (2014) 90(3):673–9. doi: 10.1016/j.ijrobp.2014.06.046

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Bondar ML, Hoogeman MS, Mens JW, Quint S, Ahmad R, Dhawtal G, et al. Individualized nonadaptive and online-adaptive intensity-modulated radiotherapy treatment strategies for cervical cancer patients based on pretreatment acquired variable bladder filling computed tomography scans. Int J Radiat Oncol Biol Phys (2012) 83(5):1617–23. doi: 10.1016/j.ijrobp.2011.10.011

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Breedveld S, Storchi PRM, Voet PWJ, Heijmen BJM. iCycle: integrated, multicriterial beam angle, and profile optimization for generation of coplanar and noncoplanar IMRT plans. Med Phys (2012) 39(2):951–63. doi: 10.1118/1.3676689

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Sharfo AWM, Breedveld S, Voet PWJ, Heijkoop ST, Mens J-WM, Hoogeman MS, et al. Validation of fully automated VMAT plan generation for library-based plan-of-the-day cervical cancer radiotherapy. PloS One (2016) 11(12):e0169202. doi: 10.1371/journal.pone.0169202

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Sharfo AWM, Voet PWJ, Breedveld S, Mens JWM, Hoogeman MS, Heijmen BJM, et al. Comparison of VMAT and IMRT strategies for cervical cancer patients using automated planning. Radiother Oncol (2015) 114(3):395–401. doi: 10.1016/j.radonc.2015.02.006

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Ramlov A, Pedersen EM, Røhl L, Worm E, Fokdal L, Lindegaard JC, et al. Risk factors for pelvic insufficiency fractures in locally advanced cervical cancer following intensity modulated radiation therapy. Int J Radiat Oncol Biol Phys (2017) 97(5):1032–9. doi: 10.1016/j.ijrobp.2017.01.026

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Gupta N, Prakash C, Chakrabarty K, Giri U, Patel A, Choudhary S. Potential advantages of bone marrow sparing IMRT in cancer cervix: a dosimetric evaluation. J Clin Diagn Res (2019) 13(4):XC01–5. doi: 10.7860/JCDR/2019/39841.12745

CrossRef Full Text | Google Scholar

28. Kumar T, Schernberg A, Busato F, Laurans M, Fumagalli I, Dumas I, et al. Correlation between pelvic bone marrow radiation dose and acute hematological toxicity in cervical cancer patients treated with concurrent chemoradiation. Cancer Manage Res (2019) 11:6285–97. doi: 10.2147/CMAR.S195989

CrossRef Full Text | Google Scholar

29. Albuquerque K, Giangreco D, Morrison C, Siddiqui M, Sinacore J, Potkul R, et al. Radiation-related predictors of hematologic toxicity after concurrent chemoradiation for cervical cancer and implications for bone marrow-sparing pelvic IMRT. Int J Radiat Oncol Biol Phys (2011) 79(4):1043–7. doi: 10.1016/j.ijrobp.2009.12.025

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Yan K, Ramirez E, Xie XJ, Gu X, Xi Y, Albuquerque K. Predicting severe hematologic toxicity from extended-field chemoradiation of para-aortic nodal metastases from cervical cancer. Pract Radiat Oncol (2018) 8(1):13–9. doi: 10.1016/j.prro.2017.07.001

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Terrones-Campos C, Ledergerber B, Vogelius IR, Helleberg M, Specht L, Lundgren J, et al. Hematological toxicity in patients with solid malignant tumors treated with radiation–temporal analysis, dose response and impact on survival. Radiother Oncol (2021) 158:175–83. doi: 10.1016/j.radonc.2021.02.029

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Corbeau A, Nout RA, Mens JWM, Horeweg N, Godart J, Kerkhof EM, et al. PROTECT: prospective phase-II-Trial evaluating adaptive proton therapy for cervical cancer to reduce the impact on morbidity and the immune system. Cancers (2021) 13(20):5179. doi: 10.3390/cancers13205179

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: VMAT, locally advanced cervical cancer, Pareto front analysis, OAR sparing, bone marrow sparing

Citation: Kuipers S, Godart J, Corbeau A, Sharfo AW, Breedveld S, Mens JW, de Boer S, Nout R and Hoogeman M (2023) The impact of bone marrow sparing on organs at risk dose for cervical cancer: a Pareto front analysis. Front. Oncol. 13:1138433. doi: 10.3389/fonc.2023.1138433

Received: 01 February 2023; Accepted: 05 June 2023;
Published: 28 June 2023.

Edited by:

Nadia Gisella Di Muzio, Vita-Salute San Raffaele University, Italy

Reviewed by:

Michele Zeverino, Centre Hospitalier Universitaire Vaudois (CHUV), Switzerland
Andrei Fodor, IRCCS San Raffaele Scientific Institute, Italy

Copyright © 2023 Kuipers, Godart, Corbeau, Sharfo, Breedveld, Mens, de Boer, Nout and Hoogeman. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Sander Kuipers, s.c.kuipers@erasmusmc.nl

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.