AUTHOR=Zhang Ke , Bile Abdiwahid Mohamed , Feng Xinyi , Xu Yemin , Li Yaoyao , She Qiang , Li Guiqing , Wu Jian , Xiao Weiming , Ding Yanbing , Deng Bin TITLE=Image acquisition as novel colonoscopic quality indicator: a single-center retrospective study JOURNAL=Frontiers in Oncology VOLUME=13 YEAR=2023 URL=https://www.frontiersin.org/journals/oncology/articles/10.3389/fonc.2023.1090464 DOI=10.3389/fonc.2023.1090464 ISSN=2234-943X ABSTRACT=Purpose

In order to reduce the incidence and mortality of colorectal cancer, improving the quality of colonoscopy is the top priority. At present, the adenoma detection rate is the most used index to evaluate the quality of colonoscopy. So, we further verified the relevant factors influencing the quality of colonoscopy and found out the novel quality indicators by studying the relationship between the influencing factors and the adenoma detection rate.

Materials/methods

The study included 3824 cases of colonoscopy from January to December 2020. We retrospectively recorded the age and sex of the subjects; the number, size, and histological features of lesions; withdrawal time and the number of images acquired during colonoscopy. We analyzed the associated factors affecting adenoma and polyp detection, and verified their effectiveness with both univariate and multivariate logistic regression analyses.

Results

Logistic regression analyses showed that gender, age, withdrawal time and the number of images acquired during colonoscopy could serve as independent predictors of adenoma/polyp detection rate. In addition, adenoma detection rate (25.36% vs. 14.29%) and polyp detection rate (53.99% vs. 34.42%) showed a marked increase when the number of images taken during colonoscopy was ≥29 (P<0.001).

Conclusions

Gender, age, withdrawal time and the number of images acquired during colonoscopy are influencing factors for the detection of colorectal adenomas and polyps. And we can gain higher adenoma/polyp detection rate when endoscopists capture more colonoscopic images.