AUTHOR=Merino Lara Tomas Rodrigo , Fleury Emmanuelle , Mashouf Shahram , Helou Joelle , McCann Claire , Ruschin Mark , Kim Anthony , Makhani Nadiya , Ravi Ananth , Pignol Jean-Philippe TITLE=Measurement of Mean Cardiac Dose for Various Breast Irradiation Techniques and Corresponding Risk of Major Cardiovascular Event JOURNAL=Frontiers in Oncology VOLUME=4 YEAR=2014 URL=https://www.frontiersin.org/journals/oncology/articles/10.3389/fonc.2014.00284 DOI=10.3389/fonc.2014.00284 ISSN=2234-943X ABSTRACT=
After breast conserving surgery, early stage breast cancer patients are currently treated with a wide range of radiation techniques including whole breast irradiation (WBI), accelerated partial breast irradiation (APBI) using high-dose rate (HDR) brachytherapy, or 3D-conformal radiotherapy (3D-CRT). This study compares the mean heart’s doses for a left breast irradiated with different breast techniques. An anthropomorphic Rando phantom was modified with gelatin-based breast of different sizes and tumors located medially or laterally. The breasts were treated with WBI, 3D-CRT, or HDR APBI. The heart’s mean doses were measured with Gafchromic films and controlled with optically stimulated luminescent dosimeters. Following the model reported by Darby (