Transcutaneous cervical vagus nerve stimulation improved motor cortex excitability in healthy adults: a randomized, single-blind, self-crossover design study

Meng-Xin Wang,Meng-Xin Wang1,2Aihaiti Wumiti,Aihaiti Wumiti1,2Yao-Wen ZhangYao-Wen Zhang2Xue-Sheng GaoXue-Sheng Gao3Zi HuangZi Huang1Meng-Fei ZhangMeng-Fei Zhang1Zhi-Yong PengZhi-Yong Peng1Yoshitaka OkuYoshitaka Oku4Zhi-Ming Tang,
Zhi-Ming Tang1,2*
  • 1Department of Rehabilitation Medicine, Yuedong Hospital, The Third Affiliated Hospital of Sun Yat-sen University, Meizhou, China
  • 2Department of Rehabilitation Medicine, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
  • 3Rehabilitation Medicine Department, Affiliated Hospital of Weifang Medical University, Weifang, China
  • 4Department of Physiology, Hyogo Medical University, Hyogo, Japan

Purpose: To investigate the effect of transcutaneous cervical vagus nerve stimulation (tcVNS) on motor cortex excitability in healthy adults.

Method: Twenty eight healthy subjects were assigned to receive real and sham tcVNS for 30 min. The interval between the real and sham conditions was more than 24 h, and the sequence was random. The central and peripheral motor-evoked potential (MEP) of the right first dorsal interosseous (FDI) muscle was measured by transcranial magnetic stimulation (TMS) before and after stimulation. MEP latency, MEP amplitude and rest motor threshold (rMT) were analyzed before and after stimulation.

Results: MEP amplitude, MEP latency and rMT had significant interaction effect between time points and conditions (p < 0.05). After real stimulation, the MEP amplitude was significantly increased (p < 0.001). MEP latency (p < 0.001) and rMT (p = 0.006) was decreased than that of baseline. The MEP amplitude on real condition was higher than that of sham stimulation after stimulation (p = 0.027). The latency after the real stimulation was significantly shorter than that after sham stimulation (p = 0.005). No significantly difference was found in rMT after stimulation between real and sham conditions (p > 0.05).

Conclusion: tcVNS could improve motor cortex excitability in healthy adults.

1. Introduction

Stroke, brain trauma, and other neurological diseases often result in extensive and lasting motor dysfunction (Nazarova et al., 2021). In some cases, such as when upper limb function is affected, the recovery process is long, which seriously affects the life of patients and places a heavy burden on the family and society (Zhao and Huang, 2019). Rehabilitation training is an important approach to improve patients’ motor function, but optimal solutions have not yet been found (Gittler and Davis, 2018).

Vagus nerve stimulation (VNS), one of many explorations of motor dysfunction rehabilitation (Kimberley et al., 2018; Li et al., 2022), can be divided into invasive and non-invasive VNS (nVNS) (Ramos-Castaneda et al., 2022). Previous studies have reported its application in cases of epilepsy (Ryvlin et al., 2021; Oehrn et al., 2022), depression (Conroy and Holtzheimer, 2021; Evensen et al., 2022), and tinnitus (De Ridder et al., 2021). Few studies have investigated its effect on motor function (Dawson and Abdul-Rahim, 2022). Porter et al. attempted to explore the effect of VNS on the motor cortex and found that repeated pairings between VNS and compression or rotation task training increased the motor cortex area of the distal and proximal forelimbs of rats, respectively (Porter et al., 2012). Dawson et al. reported that after invasive VNS (iVNS) was performed by wrapping an electrode around the left cervical vagus nerve of stroke patients, the upper limb function improved significantly better than in a regular rehabilitation training group or sham stimulation group (Dawson et al., 2021), indicating that VNS combined with motor training can improve the motor function of upper limbs. However, as this method is invasive and has high technical requirements, it is unlikely to be widely used.

nVNS includes tcVNS and transcutaneous auricular VNS (taVNS) (Yang et al., 2018; Farmer et al., 2020; Li et al., 2022; van Midden et al., 2023). Most researches on taVNS come from the study on auricular points in traditional Chinese medicine (Wang et al., 2022; Zhang et al., 2022). tcVNS is also an important kind of vagus nerve stimulation (Frangos and Komisaruk, 2017), especially with potential advantages in parameter standardization (Gurel et al., 2020). After exiting the cranial cavity through the jugular foramen, the bilateral vagus nerves run together with the common carotid artery and internal jugular vein within the carotid sheath. Their location near the surface can be identified by the medial edge of the bilateral sternocleidomastoid muscle, making it easy to locate and place stimulation electrodes. Also, the tcVNS stimulate the same branch of vagus nerve of iVNS (Gurel et al., 2020). Several pilot studies have shown that nVNS might improve motor function after stroke better than separate rehabilitation training (Capone et al., 2017; Yang et al., 2018). Compared with iVNS, which is not only expensive but carries high surgical risk, tcVNS is safer, more comfortable, and easier to carry out (Yuan and Silberstein, 2016; Redgrave et al., 2018). Moreover, it greatly reduces medical cost, which is of great clinical significance. However, although a large number of studies have been conducted on tcVNS in recent decades, the mechanism through which it improves motor function remains unclear. Objective evaluation indicators of neurophysiological effects under tcVNS are also lacking. The explanations given by most existing hypotheses rest on synaptic plasticity in neurotransmitter promotion-related pathways, and few studies have focused on the effects of VNS on motor cortex excitability.

TMS is a widely used noninvasive method of measuring motor cortex excitability (Tang et al., 2019; Zhang et al., 2022). MEP can be obtained in the dominant muscles by delivering a single pulse of magnetic stimulation in the motor cortex. MEP amplitude and MEP latency can be used to evaluate corticospinal excitability (Udupa and Chen, 2013). The increase of MEP amplitude and the shortening of cortical latency indicate increased cortical excitability.

In this study, we delivered an interference current to the neck skin to stimulate the vagus nerves’ bilateral cervical branches and assessed its safety in healthy subjects. The amplitude and latency of MEP were observed to explore the effect of bilateral tcVNS on motor cortex excitability.

2. Method

2.1. Subject

According to the preliminary experiment data, the study involved 28 healthy volunteers between the ages of 20 and 38 years old with an average age of 24.8 ± 4.4. Nine were male, and 19 were female. All participants met the inclusion criteria of being ① aged 20–35 and ② right-handed and exclusion criteria of having ① a history of mental disorder or nervous system disease, ② pacemakers, cochlear implants, dental implants, or other metal implants, and ③ severe cervical spondylosis, including cervical instability. Participants were asked to avoid alcohol, tea, and coffee, which might affect brain activity, and to keep a relatively regular routine during the study. All participants signed written informed consent to participate in the study. The study protocol was approved by the Ethics Committee of Yuedong Hospital, the Third Affiliated Hospital of Sun Yat-Sen University (approval document number: 2021–7), and the Chinese clinical trial registration number is ChiCTR2100054543.

2.2. Study design

The study used a self-crossover, randomized, single-blind controlled study design. All subjects received tcVNS in real and sham stimulation conditions on two different days with an interval of more than 24 h. The real and sham stimulus sequences were randomly assigned based on computer-generated numbers, which were kept by one person. The experiment was carried out by two operators. One person performed the tcVNS stimulation. The other operator, who did not know the stimulation conditions, used TMS to measure MEP (latency and amplitude) before and after the real or sham condition.

2.3. tcVNS stimulation

The experiment was conducted in a quiet and comfortable environment. The subjects sat in a comfortable position in a chair with arms on either side and were asked to remain relaxed.

The application conditions of tcVNS were as follows (Nagami et al., 2019): The interference current stimulation equipment was made in Japan (GentleAce neckgear J1000; J Craft, Osaka, Japan). The two pairs of electrodes (gray and white; see Figure 1) were 4 cm apart, delivering an alternating current of different frequencies (2000 Hz and 2050 Hz, respectively) to generate an interference current with a phase difference frequency of 50 Hz. The stimulation position was the bilateral cervical branch of the vagus nerve. The subject was instructed to sit in a chair, and the researchers cleaned the subject’s skin on the neck with a 75% medical alcohol swab. Two pairs of electrodes, each consisting of one gray and one white electrode, were affixed onto separate skin patches with a 4 cm distance between them. The patches were symmetrically placed bilaterally on the neck. The gray electrodes were positioned at the intersection of the thyroid cartilage and the front edge of the sternocleidomastoid muscle. The white electrodes were placed in a straight line between the mandibular angle and the corresponding gray electrodes on both sides (as depicted in Figure 1). Stimulation intensity was adjusted using a graded approach control software on a tablet computer, with a minimum stimulation intensity of 0.1 mA. However, each subsequent level of intensity did not necessarily result in an equivalent increase in actual output current. Under the real stimulation condition, to ensure safety and avoid excessive stimulation, the experimenters adjusted the stimulation intensity to maintain it between a range of 2.5 mA to 3.0 mA for a duration of 30 min. As individuals have different sensory thresholds, the sensations experienced by participants during the stimulation were not uniform. However, most participants reported tolerable vibratory sensations. This precise approach to controlling stimulation intensity ensured the safety of the participants. Under the sham stimulation condition, the setting was maintained for a total of 30 min with the device turn off To maintain single blinding, a designated data analyst conducted the statistical analysis without knowledge of the stimulation conditions and remained unaware of whether the data came from the real or sham stimulation conditions until all analyses were completed. This stringent approach minimized the risk of biased data analysis and enhanced the credibility and robustness of the study findings.

FIGURE 1
www.frontiersin.org

Figure 1. The stimulation electrode’s location of tcVNS.

2.4. Transcranial magnetic stimulation

The method was as explained in our previous studies (Tang et al., 2019; Zhang J. et al., 2022; Zhang M. F. et al., 2022). The subject sat relaxed in a high-backed chair with armrests which supported their forearms, back, and legs. The subject was advised not to move their body during the rest motor threshold (rMT) and MEP measurements to keep the coil in the same position (Figure 2).

FIGURE 2
www.frontiersin.org

Figure 2. Assessment of MEP by transcranial magnetic stimulation. (A) The coil located on the M1 to assess the MEP amplitude and latency. (B) The electrode on the FDI (below) and the MEP waveform.

A facial scrub was used to clean the skin of the subject’s first dorsal interosseous (FDI) muscle to ensure a low skin impedance of ≤10 kΩ. A pair of 1 cm diameter bipolar disposable surface electrodes was attached to the FDI muscle of the right hand at a distance of 1.5 cm (Figure 2C). The ground electrode was placed on the right ulnar styloid process. The MEP was recorded by EMG (Neuron-Spectrum-5, Russia) with filtering set at 5–10KHz, sampling rate at 25KHz, and scanning speed at 5 ms/div.

The subjects kept their bilateral upper limb muscles relaxed and wore positioning caps. C3 was used as the reference point to locate the hand representative region in the primary motor cortex according to the international 10–20 EEG localization standard. TMS equipment (Wuhan Yiruide Medical Equipment New Technology Co., Ltd., China) was used with a figure-eight coil, which consists of two small circular coils with a diameter of 9 cm and opposite current directions overlapping each other, to measure MEP. The coil was tangent to the scalp, and the handle was at a 45-degree angle from the midline of the body (Figure 2A). The 70% maximum machine intensity of the TMS was selected as the baseline to initiate stimulation. The location around C3 that consistently elicited large-amplitude MEP was identified as the “hotspot.” According to previous guidelines, we employed the relative frequency method to determine the TMS output intensity (Rossini et al., 2015). It was reduced as it approached the threshold until the lowest output intensity was able to evoke at least 5 MEPs with amplitudes >50 μV of 10 consecutive TMS stimulations. This output intensity was defined as rMT. Before and after tcVNS stimulation, we stimulated the “hotspot” with 120% rMT intensity TMS to obtain the corticospinal MEP (Tang et al., 2019; Zhang et al., 2022). Any MEPs that were contaminated by activity in other muscles or had an amplitude less than 50 μV were excluded from the analysis. Ten MEP were recorded (Yang et al., 2017; Sun et al., 2019; Tang et al., 2019), and their peak MEP amplitude and latency were calculated (Figure 2C).The mean of the ten MEPs was used for further analysis.

2.5. Safety monitoring

The subject’s heart rate and blood oxygen were monitored during the study by a pulse oximetry device (POD3, Heal Force, Ltd. Shenzhen, China) worn on their right index finger. The experiment was stopped immediately if the heart rate fell below 60 or adverse reactions occurred, such as difficult breathing, unbearable skin tingling, or dizziness.

2.6. Statistical analysis

The G Power 3.1 statistical tool was used to determine the required sample size for the present trials based on the results of pre-experiments and the desired statistical power of 80% with statistical significance at p < 0.05 (2-tailed test). The analysis showed that at least 20 subjects were required for the study.

SPSS 23.0 software was used to analyze the data. We used the Shapiro–Wilk test to perform normality distribution. Data were expressed as mean ± standard deviation (SD); two factor (time * condition) repeated measurement ANOVA was used to compare the differences among each assessment point and post-Hoc using Bonferroni correction was used to compare the differences in MEP amplitude, MEP latency and rMT before and after stimulation within each condition. p < 0.05 was considered statistically significant.

3. Results

3.1. Changes of MEP amplitude

There was a significant interaction effect between measurement time points and conditions (F1, 27 = 7.039, p = 0.013) (Figure 3). Significantly main effect was found in time points (F1,27 = 29.473, p < 0.001). No significant main effect was found in conditions (F1,27 = 2.307, p = 0.140).

FIGURE 3
www.frontiersin.org

Figure 3. MEP amplitude on Real and Sham condition. The MEP Amplitude was significantly increased on real condition after tcVNS (p < 0.001). After tcVNS, MEP Amplitude was higher in real condition compared to the sham condition (p = 0.027).

After real stimulation, the MEP amplitude (0.73 ± 0.36 mV) was significantly higher than that before stimulation (0.43 ± 0.22 mV) (t = 4.185, p < 0.001). However, the MEP amplitude after the sham stimulation (0.52 ± 0.31 mV) did not change significantly compared with that before the stimulation (0.49 ± 0.24 mV) (t = 0.784, p = 0.440). There was significant difference of MEP amplitude between the real and sham condition after stimulation (t = 2.342, p = 0.027).

3.2. Change of the MEP latency

As shown in Figure 4, there was a significant interaction effect between time points and conditions (F1,27 = 21.316, p < 0.001). Significantly main effect was found in time points (F1,27 = 19.746, p < 0.001). No significant main effect was found in conditions (F1,27 = 0.621, p = 0.438).

FIGURE 4
www.frontiersin.org

Figure 4. MEP latency on Real and Sham condition. MEP latency significantly decreased on real condition after tcVNS (p < 0.001). After tcVNS, MEP latency was shorten real condition compared to the sham condition (p = 0.005).

The MEP latency after real stimulation (20.03 ± 1.68 ms) was significantly shorter than before stimulation (20.81 ± 1.64 ms) (t = 6.173, p < 0.001), while there was no statistically significant change in the MEP latency before and after the sham stimulation (20.57 ± 1.11 ms vs. 20.50 ± 1.26 ms) (t = 0.649, p = 0.522). The latency after the real stimulation was significantly shorter than that after sham stimulation (t = 3.093, p = 0.005).

3.3. Change of the rMT

As shown in Figure 5, there was a significant interaction effect between measurement time points (F1,27 = 9.097, p = 0.006). No significant main effect was found in time points (F1,27 = 3.645, p = 0.067). No significant main effect was found in conditions (F1,27 = 0.248, p = 0.622).

FIGURE 5
www.frontiersin.org

Figure 5. rMT on Real and Sham condition. rMT significantly decreased on real condition after tcVNS (p = 0.006).

The rMT after real stimulation (55.04 ± 9.95%) was significantly decreased than before stimulation (57.18 ± 9.59%) (t = 2.993, p = 0.006), while there was also no statistically significant change in the rMT before and after the sham stimulation (55.58 ± 10.10% vs. 55.83 ± 10.32%) (t = 0.461, p = 0.648). There was no significant difference after the real stimulation and that of after sham stimulation (t = 0.866, p = 0.394).

3.4. Safety

At the onset of real stimulation, three participants experienced mild skin tingling, which was tolerable and quickly adapted to. No other adverse reactions were reported.

4. Discussion

tcVNS can now safely stimulate the vagus nerve without injury, and it is becoming widely used in various functional disorders in stroke rehabilitation. However, how tcVNS activates the relevant brain regions and produces central effects to improve motor function remains to be explored. This study investigated the effect of tcVNS on the excitability of the motor cortex. The increase in MEP amplitude and the shortening of latency prompted the corticospinal tract, suggesting that tcVNS could significantly improve the excitability of the motor cortex.

nVNS includes both tcVNS and taVNS. Some previous studies have investigated the taVNS on the motor function, but few have investigated this in relation to tcVNS (Frangos and Komisaruk, 2017). Redgrave et al. combined taVNS with post-stroke upper limb rehabilitation, and found improvement in motor function in a pilot study (Redgrave et al., 2018). Capone et al. reported that taVNS combined with robot-assisted rehabilitation might promote the motor function of the upper limb (Capone et al., 2017). However, they only assessed the clinical effectiveness and did not investigate the mechanism. Our previous studies have found that stimulation of the auricular vagus nerve by auricular acupuncture can improve the excitability of the motor cortex (Zhang et al., 2022). Based on this premise, the current study utilized interference current to stimulate both bilateral cervical vagus nerves, and innovatively found that tcVNS can increase the excitability of the motor cortex. This was demonstrated by the increased MEP amplitude and the shortened latency, indicating the activation of the corticospinal tract.

Many studies have used animal models to investigate the central nervous mechanism of VNS and considered that VNS activates the basal nucleus (Lyubashina and Panteleev, 2009), locus coeruleus (Hilz, 2022), and dorsal raphe nucleus (Hulsey et al., 2019) through the nucleus tractus solitarius (NTS) after the vagus nerve (Cooper et al., 2021). This causes an extensive release of norepinephrine, acetylcholine, serotonin, and other neurotransmitters in the cortex, combined with specific rehabilitation tasks targeted to promote synaptic plasticity in these neural pathways (Hulsey et al., 2019). Some researchers have found that inhibition of norepinephrine re-uptake could enhance excitability of the corticospinal tract, which may be the physiological mechanism whereby VNS promotes cortical excitability (Roosevelt et al., 2006; Kuo et al., 2017).

However, few studies have investigated the direct effect of nVNS on brain excitability. MEP is a reliable indicator to measure cortical excitability (Tang et al., 2019; Zhang J. et al., 2022; Zhang M. F. et al., 2022). We used latency and amplitude to evaluate the effect of VNS on the excitability of the motor cortex and used sham stimulation to eliminate possible placebo effects. The MEP amplitude of the real stimulus condition was significantly higher than that before the tcVNS. No significant changes was found on sham stimulation condition. MEP amplitude may be affected by both long term inhibitory and excitatory effects induced by TMS stimulation (Di Lazzaro et al., 2004; Mercante et al., 2015). Some previous studies reported that VNS induced short interval intracortical inhibition (Capone et al., 2015; van Midden et al., 2023). So that the MEP amplitude cannot sensitively reflect the changes of M1 plasticity (Vallence et al., 2023). The change of MEP latency can compensate for the lack of MEP amplitude. Latency reflects the time required for intra-cortical processing, corticocortical conduction, spinal processing, and neuromuscular transmission, depending on the state of the corticospinal system at the time of TMS delivery. The change of state at any point along the corticospinal pathway may affect the MEP latency (Hirano et al., 2016).

We used a crossover study design and a random stimulus sequence to ensure that different participants and the stimulus sequence did not affect the experimental results. The interval between the two stimulus conditions should be at least 24 h to avoid possible legacy effects. Considering the parasympathetic effect of the vagus nerve, the safety of stimulating bilateral vagus nerve simultaneously is still controversial. In previous studies, unilateral VNS has mostly been selected. One previous study reported that bilateral nVNS through the neck is safe (Nagami et al., 2019). In addition, previous reports have used a pulse current to stimulate the cervical vagus nerve (Dawson et al., 2021; De Ridder et al., 2021). However, we used a 50-Hz interference current, which is more comfortable than the pulse current interference wave because it does not cause muscle contraction.

This study also has several limitations. First, we did not attempt to investigate the optimal parameters for tcVNS treatment, such as intensive, duration. Second, only the MEP of the motor cortex of the left hemisphere was measured while both vagus nerves were stimulated bilaterally. Third, the sample size of this study was small, and the participants were mostly 20–30 years old, fewer male subjects. Fourth, this study only carried out a single stimulation, and the long-term effect of VNS on the motor cortex remains unclear. In addition, most participants were able to distinguish between real and sham stimulation due to the significant differences in intensity. Therefore, a single-blind design was employed in this study. Finally, this study suggested the activation of tcVNS on the corticospinal tract, but the specific neural pathway remains unknown. We need to explore this point in a follow-up study further.

5. Conclusion

In conclusion, bilateral tcVNS could safely and effectively increase the excitability of the motor cortex and may become a new treatment to improve motor function in central neural injured patients.

Data availability statement

The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author.

Ethics statement

The studies involving humans were approved by the Ethics Committee of Yuedong Hospital, the Third Affiliated Hospital of Sun Yat-Sen University. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.

Author contributions

Z-MT is the guarantor of this study. YO and Z-MT participated in the conception and design of the study and also participated in the critical revision of the manuscript. M-XW was stimulation operator and AW was evaluator. Y-WZ contributed to participant recruitment. X-SG and ZH were involved with data collection. M-FZ and Z-YP finished data analysis. M-XW and AW prepared the first draft of this manuscript. All authors read and approved the final manuscript.

Funding

This work was supported by Medical Scientific Research Foundation of Guangdong Province (A2022240, B20323071) and the Hospital Grant of Yuedong Hospital, The Third Affiliated Hospital of Sun Yat-sun University (202202).

Acknowledgments

The authors would like to thank all the participants.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

Capone, F., Assenza, G., Di Pino, G., Musumeci, G., Ranieri, F., Florio, L., et al. (2015). The effect of transcutaneous vagus nerve stimulation on cortical excitability. J. Neural Trans. Gen. Sec. 122, 679–685. doi: 10.1007/s00702-014-1299-7

CrossRef Full Text | Google Scholar

Capone, F., Miccinilli, S., Pellegrino, G., Zollo, L., Simonetti, D., Bressi, F., et al. (2017). Transcutaneous Vagus nerve stimulation combined with robotic rehabilitation improves upper limb function after stroke. Neural Plast. 2017:7876507.

Google Scholar

Conroy, S. K., and Holtzheimer, P. E. (2021). Neuromodulation strategies for the treatment of depression. Am. J. Psychiatry 178, 1082–1088. doi: 10.1176/appi.ajp.2021.21101034

PubMed Abstract | CrossRef Full Text | Google Scholar

Cooper, C. M., Farrand, A. Q., Andresen, M. C., and Beaumont, E. (2021). Vagus nerve stimulation activates nucleus of solitary tract neurons via supramedullary pathways. J. Physiol. 599, 5261–5279. doi: 10.1113/JP282064

PubMed Abstract | CrossRef Full Text | Google Scholar

Dawson, J., and Abdul-Rahim, A. H. (2022). Paired vagus nerve stimulation for treatment of upper extremity impairment after stroke. Int. J. Stroke 17, 1061–1066. doi: 10.1177/17474930221094684

CrossRef Full Text | Google Scholar

Dawson, J., Liu, C. Y., Francisco, G. E., Cramer, S. C., Wolf, S. L., Dixit, A., et al. (2021). Vagus nerve stimulation paired with rehabilitation for upper limb motor function after ischaemic stroke (VNS-REHAB): a randomised, blinded, pivotal, device trial. Lancet 397, 1545–1553. doi: 10.1016/S0140-6736(21)00475-X

PubMed Abstract | CrossRef Full Text | Google Scholar

De Ridder, D., Langguth, B., and Vanneste, S. (2021). Vagus nerve stimulation for tinnitus: a review and perspective. Prog. Brain Res. 262, 451–467. doi: 10.1016/bs.pbr.2020.08.011

PubMed Abstract | CrossRef Full Text | Google Scholar

Di Lazzaro, V., Oliviero, A., Pilato, F., Saturno, E., Dileone, M., Meglio, M., et al. (2004). Effects of vagus nerve stimulation on cortical excitability in epileptic patients. Neurology 62, 2310–2312.

PubMed Abstract | Google Scholar

Evensen, K., Jorgensen, M. B., Sabers, A., and Martiny, K. (2022). Transcutaneous vagal nerve stimulation in treatment-resistant depression: a feasibility study. Neuromodulation 25, 443–449. doi: 10.1111/ner.13366

PubMed Abstract | CrossRef Full Text | Google Scholar

Farmer, A. D., Strzelczyk, A., Finisguerra, A., Gourine, A. V., Gharabaghi, A., Hasan, A., et al. (2020). International consensus based review and recommendations for minimum reporting standards in research on transcutaneous Vagus nerve stimulation (version 2020). Front. Hum. Neurosci. 14:568051. doi: 10.3389/fnhum.2020.568051

CrossRef Full Text | Google Scholar

Frangos, E., and Komisaruk, B. R. (2017). Access to vagal projections via cutaneous electrical stimulation of the neck: fMRI evidence in healthy humans. Brain Stimul. 10, 19–27. doi: 10.1016/j.brs.2016.10.008

PubMed Abstract | CrossRef Full Text | Google Scholar

Gittler, M., and Davis, A. M. (2018). Guidelines for adult stroke rehabilitation and recovery. JAMA 319, 820–821. doi: 10.1001/jama.2017.22036

PubMed Abstract | CrossRef Full Text | Google Scholar

Gurel, N. Z., Huang, M., Wittbrodt, M. T., Jung, H., Ladd, S. L., Shandhi, M. M. H., et al. (2020). Quantifying acute physiological biomarkers of transcutaneous cervical vagal nerve stimulation in the context of psychological stress. Brain Stimul. 13, 47–59. doi: 10.1016/j.brs.2019.08.002

PubMed Abstract | CrossRef Full Text | Google Scholar

Gurel, N. Z., Wittbrodt, M. T., Jung, H., Shandhi, M. M. H., Driggers, E. G., Ladd, S. L., et al. (2020). Transcutaneous cervical vagal nerve stimulation reduces sympathetic responses to stress in posttraumatic stress disorder: a double-blind, randomized, sham controlled trial. Neurobiol. Stress 13:100264

Google Scholar

Hilz, M. J. (2022). Transcutaneous vagus nerve stimulation - a brief introduction and overview. Auton. Neurosci. 243:103038. doi: 10.1016/j.autneu.2022.103038

CrossRef Full Text | Google Scholar

Hirano, M., Kubota, S., Koizume, Y., Tanaka, S., and Funase, K. (2016). Different effects of implicit and explicit motor sequence learning on latency of motor evoked potential evoked by transcranial magnetic stimulation on the primary motor cortex. Front. Hum. Neurosci. 10:671. doi: 10.3389/fnhum.2016.00671

CrossRef Full Text | Google Scholar

Hulsey, D. R., Shedd, C. M., Sarker, S. F., Kilgard, M. P., and Hays, S. A. (2019). Norepinephrine and serotonin are required for vagus nerve stimulation directed cortical plasticity. Exp. Neurol. 320:112975. doi: 10.1016/j.expneurol.2019.112975

CrossRef Full Text | Google Scholar

Kimberley, T. J., Pierce, D., Prudente, C. N., Francisco, G. E., Yozbatiran, N., Smith, P., et al. (2018). Vagus nerve stimulation paired with upper limb rehabilitation after chronic stroke. Stroke 49, 2789–2792. doi: 10.1161/STROKEAHA.118.022279

CrossRef Full Text | Google Scholar

Kuo, H. I., Paulus, W., Batsikadze, G., Jamil, A., Kuo, M. F., and Nitsche, M. A. (2017). Acute and chronic noradrenergic effects on cortical excitability in healthy humans. Int. J. Neuropsychopharmacol. 20, 634–643. doi: 10.1093/ijnp/pyx026

PubMed Abstract | CrossRef Full Text | Google Scholar

Li, L., Wang, D., Pan, H., Huang, L., Sun, X., He, C., et al. (2022). Non-invasive Vagus nerve stimulation in cerebral stroke: current status and future perspectives. Front. Neurosci. 16:820665. doi: 10.3389/fnins.2022.820665

CrossRef Full Text | Google Scholar

Li, J. N., Xie, C. C., Li, C. Q., Zhang, G. F., Tang, H., Jin, C. N., et al. (2022). Efficacy and safety of transcutaneous auricular vagus nerve stimulation combined with conventional rehabilitation training in acute stroke patients: a randomized controlled trial conducted for 1 year involving 60 patients. Neural Regen. Res. 17, 1809–1813. doi: 10.4103/1673-5374.332155

PubMed Abstract | CrossRef Full Text | Google Scholar

Lyubashina, O., and Panteleev, S. (2009). Effects of cervical vagus nerve stimulation on amygdala-evoked responses of the medial prefrontal cortex neurons in rat. Neurosci. Res. 65, 122–125. doi: 10.1016/j.neures.2009.06.002

PubMed Abstract | CrossRef Full Text | Google Scholar

Mercante, B., Pilurzi, G., Ginatempo, F., Manca, A., Follesa, P., Tolu, E., et al. (2015). Trigeminal nerve stimulation modulates brainstem more than cortical excitability in healthy humans. Exp. Brain Res. 233, 3301–3311. doi: 10.1007/s00221-015-4398-2

PubMed Abstract | CrossRef Full Text | Google Scholar

Nagami, S., Maeda, K., Fukunaga, S., Ikeno, M., and Oku, Y. (2019). Safety of transcutaneous electrical sensory stimulation of the neck in terms of vital parameters in dysphagia rehabilitation. Sci. Rep. 9:13481. doi: 10.1038/s41598-019-49954-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Nazarova, M., Kulikova, S., Piradov, M. A., Limonova, A. S., Dobrynina, L. A., Konovalov, R. N., et al. (2021). Multimodal assessment of the motor system in patients with chronic ischemic stroke. Stroke 52, 241–249. doi: 10.1161/STROKEAHA.119.028832

CrossRef Full Text | Google Scholar

Oehrn, C. R., Molitor, L., Krause, K., Niehaus, H., Schmidt, L., Hakel, L., et al. (2022). Non-invasive vagus nerve stimulation in epilepsy patients enhances cooperative behavior in the prisoner's dilemma task. Sci. Rep. 12:10255. doi: 10.1038/s41598-022-14237-3

PubMed Abstract | CrossRef Full Text | Google Scholar

Porter, B. A., Khodaparast, N., Fayyaz, T., Cheung, R. J., Ahmed, S. S., Vrana, W. A., et al. (2012). Repeatedly pairing vagus nerve stimulation with a movement reorganizes primary motor cortex. Cereb. Cortex 22, 2365–2374. doi: 10.1093/cercor/bhr316

PubMed Abstract | CrossRef Full Text | Google Scholar

Ramos-Castaneda, J. A., Barreto-Cortes, C. F., Losada-Floriano, D., Sanabria-Barrera, S. M., Silva-Sieger, F. A., and Garcia, R. G. (2022). Efficacy and safety of Vagus nerve stimulation on upper limb motor recovery after stroke. A systematic review and Meta-analysis. Front. Neurol. 13:889953. doi: 10.3389/fneur.2022.889953

CrossRef Full Text | Google Scholar

Redgrave, J., Day, D., Leung, H., Laud, P. J., Ali, A., Lindert, R., et al. (2018). Safety and tolerability of transcutaneous Vagus nerve stimulation in humans; a systematic review. Brain Stimul. 11, 1225–1238. doi: 10.1016/j.brs.2018.08.010

PubMed Abstract | CrossRef Full Text | Google Scholar

Redgrave, J. N., Moore, L., Oyekunle, T., Ebrahim, M., Falidas, K., Snowdon, N., et al. (2018). Transcutaneous auricular Vagus nerve stimulation with concurrent upper limb repetitive task practice for Poststroke motor recovery: a pilot study. J. Stroke Cerebrovasc. Dis. 27, 1998–2005. doi: 10.1016/j.jstrokecerebrovasdis.2018.02.056

PubMed Abstract | CrossRef Full Text | Google Scholar

Roosevelt, R. W., Smith, D. C., Clough, R. W., Jensen, R. A., and Browning, R. A. (2006). Increased extracellular concentrations of norepinephrine in cortex and hippocampus following vagus nerve stimulation in the rat. Brain Res. 1119, 124–132. doi: 10.1016/j.brainres.2006.08.048

PubMed Abstract | CrossRef Full Text | Google Scholar

Rossini, P. M., Burke, D., Chen, R., Cohen, L. G., Daskalakis, Z., Di Iorio, R., et al. (2015). Non-invasive electrical and magnetic stimulation of the brain, spinal cord, roots and peripheral nerves: basic principles and procedures for routine clinical and research application. An updated report from an I.F.C.N Committee. Clin. Neurophysiol. 126, 1071–1107. doi: 10.1016/j.clinph.2015.02.001

PubMed Abstract | CrossRef Full Text | Google Scholar

Ryvlin, P., Rheims, S., Hirsch, L. J., Sokolov, A., and Jehi, L. (2021). Neuromodulation in epilepsy: state-of-the-art approved therapies. Lancet Neurol. 20, 1038–1047. doi: 10.1016/S1474-4422(21)00300-8

PubMed Abstract | CrossRef Full Text | Google Scholar

Sun, Z. G., Pi, Y. L., Zhang, J., Wang, M., Zou, J., and Wu, W. (2019). Effect of acupuncture at ST36 on motor cortical excitation and inhibition. Brain Behav. 9:e01370

Google Scholar

Tang, Z. M., Xuan, C. Y., Li, X., Dou, Z. L., Lan, Y. J., and Wen, H. M. (2019). Effect of different pulse numbers of transcranial magnetic stimulation on motor cortex excitability: single-blind, randomized cross-over design. CNS Neurosci. Ther. 25, 1277–1281. doi: 10.1111/cns.13248

PubMed Abstract | CrossRef Full Text | Google Scholar

Udupa, K., and Chen, R. (2013). Central motor conduction time. Handb. Clin. Neurol. 116, 375–386. doi: 10.1016/B978-0-444-53497-2.00031-0

PubMed Abstract | CrossRef Full Text | Google Scholar

Vallence, A. M., Rurak, B. K., Fujiyama, H., and Hammond, G. R. (2023). Covariation of the amplitude and latency of motor evoked potentials elicited by transcranial magnetic stimulation in a resting hand muscle. Exp. Brain Res. 241, 927–936. doi: 10.1007/s00221-023-06575-z

PubMed Abstract | CrossRef Full Text | Google Scholar

van Midden, V. M., Demšar, J., Pirtošek, Z., and Kojović, M. (2023). The effects of transcutaneous auricular vagal nerve stimulation on cortical GABAergic and cholinergic circuits: a transcranial magnetic stimulation study. Eur. J. Neurosci. 57, 2160–2173. doi: 10.1111/ejn.16004

PubMed Abstract | CrossRef Full Text | Google Scholar

Wang, L., Zhang, J., Guo, C., He, J., Zhang, S., Wang, Y., et al. (2022). The efficacy and safety of transcutaneous auricular vagus nerve stimulation in patients with mild cognitive impairment: a double blinded randomized clinical trial. Brain Stimul. 15, 1405–1414. doi: 10.1016/j.brs.2022.09.003

PubMed Abstract | CrossRef Full Text | Google Scholar

Yang, Y., Eisner, I., Chen, S., Wang, S., Zhang, F., and Wang, L. (2017). Neuroplasticity changes on human motor cortex induced by acupuncture therapy: a preliminary study. Neural Plast. 2017:4716792.

Google Scholar

Yang, Y., Yang, L. Y., Orban, L., Cuylear, D., Thompson, J., Simon, B., et al. (2018). Non-invasive vagus nerve stimulation reduces blood-brain barrier disruption in a rat model of ischemic stroke. Brain Stimul. 11, 689–698. doi: 10.1016/j.brs.2018.01.034

PubMed Abstract | CrossRef Full Text | Google Scholar

Yuan, H., and Silberstein, S. D. (2016). Vagus nerve and Vagus nerve stimulation, a comprehensive review: part III. Headache 56, 479–490. doi: 10.1111/head.12649

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhang, M. F., Chen, W. Z., Huang, F. B., Peng, Z. Y., Quan, Y. C., and Tang, Z. M. (2022). Low-intensity transcranial ultrasound stimulation facilitates hand motor function and cortical excitability: a crossover, randomized, double blind study. Front. Neurol. 13:926027

Google Scholar

Zhang, J., Huang, W. H., Zheng, Y. D., Li, X., Jiang, H. X., Su, M. Z., et al. (2022). Effects of auricular acupuncture stimulation on healthy adults' upper limb motor-evoked potentials: a randomized, crossover, double-blind study. Front. Neurosci. 16:895602. doi: 10.3389/fnins.2022.895602

CrossRef Full Text | Google Scholar

Zhao, H. L., and Huang, Y. (2019). Lifetime risk of stroke in the global burden of disease study. N. Engl. J. Med. 380, 1377–1378. doi: 10.1056/NEJMc1900607

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: noninvasive vagus nerve stimulation, motor cortex excitability, neuromodulation, transcranial magnetic stimulation, motor evoke potential

Citation: Wang M-X, Wumiti A, Zhang Y-W, Gao X-S, Huang Z, Zhang M-F, Peng Z-Y, Oku Y and Tang Z-M (2023) Transcutaneous cervical vagus nerve stimulation improved motor cortex excitability in healthy adults: a randomized, single-blind, self-crossover design study. Front. Neurosci. 17:1234033. doi: 10.3389/fnins.2023.1234033

Received: 20 June 2023; Accepted: 18 September 2023;
Published: 03 October 2023.

Edited by:

Minoru Fujiki, Oita University, Japan

Reviewed by:

Francesca Ginatempo, University of Sassari, Italy
Federico Villagra, Aberystwyth University, United Kingdom

Copyright © 2023 Wang, Wumiti, Zhang, Gao, Huang, Zhang, Peng, Oku and Tang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Zhi-Ming Tang, tangzhm3@mail.sysu.edu.cn

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.