Stent placement can be an effective treatment for patients with symptomatic intracranial stenosis (sICAS) and hemodynamic impairment (HI). However, the association between lesion length and the risk of recurrent cerebral ischemia (RCI) after stenting remains controversial. Exploring this association can help predict patients at higher risk for RCI and develop individualized follow-up schedules.
In this study, we provided a
The non-linear relationship between lesion length and RCI was observed in the overall population and subgroups; however, the non-linear relationship differed by subgroup of stent type. In the balloon-expandable stent (BES) subgroup, the risk of RCI increased 2.17-fold and 3.17-fold for each 1-mm increase in the lesion length when the lesion length was <7.70 mm and >9.00 mm, respectively. In the self-expanding stent (SES) subgroup, the risk of RCI increased 1.83-fold for each 1-mm increase in the lesion length when the length was <9.00 mm. Nevertheless, the risk of RCI did not increase with the length when the lesion length was >9.00mm.
A non-linear relationship exists between lesion length and RCI after stenting for sICAS with HI. The lesion length increases the overall risk of RCI for BES and for SES when the length was <9.00 mm, while no significant relationship was found when the length was >9.00 mm for SES.