Skip to main content

EDITORIAL article

Front. Neurol., 18 July 2022
Sec. Experimental Therapeutics
This article is part of the Research Topic Current State and Future Directions of Cranial Focused Ultrasound Therapy View all 10 articles

Editorial: Current state and future directions of cranial focused ultrasound therapy

  • 1Department of Radiology, Hospital for Special Surgery, New York, NY, United States
  • 2Department of Neurosurgery, The Ohio State University, Columbus, OH, United States
  • 3Department of Neurosurgery, University of North Carolina, Chapel Hill, NC, United States

Transcranial focused ultrasound (FUS) is a transformative technology to treat neurological and psychiatric disorders. Following pre-clinical development for decades, FUS ablation received FDA approval for essential tremor (ET) treatment in July 2016 (1). The field has undergone rapid development with innovations in image guidance (2, 3), technique optimization (4), and expansion of target selection beyond the thalamus (57). In addition to cranial ablation, focused ultrasound can transiently open the transient blood-brain barrier (BBB) in targeted locations and is being actively tested for applications in Alzheimer's disease and brain tumors for targeted drug delivery (810).

The current collection of articles highlights the recent innovations in clinical and investigational applications of FUS. Walker et al. discuss the application of DWI and diffusion tractography to visualize the sciatic nerve in piglets They demonstrate reliable sciatic nerve visualization and disruption following MRgFUS ablation in an animal model with histopathologic correlation. This research expands the reach of MRgFUS ablation to the peripheral nervous system and may lead to clinical applications for pain relief with durable nerve conduction blocks (11, 12).

Ahmed A-K et al. explore the impact of ablation location (thalamotomy vs. pallidotomy) on treatment efficiency in a cohort of 40 patients with matched skull density ratios (SDR). Acoustic and thermal simulations were performed at each target, and the findings confirm that globus pallidus interna ablation, located further from the geometric center of the skull, was associated with a higher energy requirement when compared with thalamic ablation. This data has important implications for patient selection for pallidotomy and other off-center ablation targets.

Ahmed N et al. present a thorough review of MRgFUS applications for therapeutic cell delivery in the brain through BBB opening techniques. The authors review the existing methodology of intracerebral cell delivery, including vascular, intrathecal, and stereotactic delivery techniques. Current and future potential for clinical translation is reviewed with applications in neurodegenerative disease, malignancy, autoimmune disorders, and stroke therapy.

Stanziano et al. present data on the resting-state functional MRI connectome in patients with tremor-dominant Parkinson's disease undergoing FUS thalamotomy. Baseline, 1-month, and 3-month connectome data were evaluated for differences in connectivity using a comparative region of interest analysis. The results shed light on changes in functional connectivity between primary motor cortices, supplementary motor cortices, cingulate cortex, and lobe VI of the cerebellar hemispheres. In addition, correlative changes in functional connectivity were observed to a different extent in patients who had a positive clinical response.

Pujol et al. present DTI tractography parcellation of the hyperdirect pathway projections from the M1 cortex and reveals a somatotopic organization by the trunk, arm, hand, face, and tongue. This study analyzed the Human Connectome Project data and should have important implications for patient-specific tractography. By defining patient-specific somatotopy, practitioners could better define ablation targets and avoid off-target effects from FUS ablation.

Agrawal et al. present a systemic review and meta-analysis pooling results from 29 studies of the clinical outcomes and complications of MRgFUS ventral intermediate (Vim) thalamic nucleus ablation for ET patients. Importantly, the analysis revealed a statistically significant reduction in postprocedural ataxia when DTI-based targeted was employed. This review not only supports robust clinical outcomes from Vim ablation in ET patients but reinforces the benefits of diffusion tractography in target selection.

Fishman and Fischell present a review of existing and future techniques for BBB opening to treat neurodegenerative disease. Pre-clinical studies on the delivery of growth factors, antibodies, viral vectors, and nanoparticles into the brain with targeted BBB opening are reviewed. Safety data on the BBB opening technique is presented with a thoughtful reflection on future directions.

Lak et al. present a single-center experience with 160 thalamic FUS ablations in patients with ET or tremor-dominant Parkinson's disease, the largest experience published thus far. They report MRgFUS thalamotomy is a safe and effective procedure with a mean 78% tremor reduction at 2 years. In addition, the most observed side effects at 2 years were imbalance followed by sensory disturbance. This data further bolsters existing literature on the safety and efficacy of MRgFUS thalamotomy.

We anticipate this collection will be of great interest to seasoned and new practitioners of cranial MRgFUS. The field has undergone rapid innovation with exciting future horizons.

Author contributions

JC, FS, and VK: manuscript preparation and editing. All authors contributed to the article and approved the submitted version.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Elias WJ, Lipsman N, Ondo WG, Ghanouni P, Kim YG, Lee W, et al. A randomized trial of focused ultrasound thalamotomy for essential tremor. N Engl J Med. (2016) 375:730–9. doi: 10.1056/NEJMoa1600159

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Chazen JL, Sarva H, Stieg PE, Min RJ, Ballon DJ, Pryor KO, et al. Clinical improvement associated with targeted interruption of the cerebellothalamic tract following MR-guided focused ultrasound for essential tremor. J Neurosurg. (2018) 129:315–23. doi: 10.3171/2017.4.JNS162803

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Krishna V, Sammartino F, Agrawal P, Changizi BK, Bourekas E, Knopp MV, et al. Prospective tractography-based targeting for improved safety of focused ultrasound thalamotomy. Neurosurgery. (2019) 84:160–8. doi: 10.1093/neuros/nyy020

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Sammartino F, Snell J, Eames M, Krishna V. Thermal neuromodulation with focused ultrasound: implications for the technique of subthreshold testing. Neurosurgery. (2021) 89:610–6. doi: 10.1093/neuros/nyab238

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Gallay MN, Moser D, Rossi F, Magara AE, Strasser M, Bühler R, et al. MRgFUS pallidothalamic tractotomy for chronic therapy-resistant Parkinson's disease in 51 Consecutive patients: single center experience. Front Surg. (2019) 6:76. doi: 10.3389/fsurg.2019.00076

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Eisenberg HM, Krishna V, Elias WJ, Cosgrove GR, Gandhi D, Aldrich CE, et al. MR-guided focused ultrasound pallidotomy for Parkinson's disease: safety and feasibility. J Neurosurg. (2020) 135:1–7. doi: 10.3171/2020.6.JNS192773

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Martinez-Fernandez R, Manez-Miro JU, Rodriguez-Rojas R, Del Álamo M, Shah BB, Hernández-Fernández F, et al. randomized trial of focused ultrasound subthalamotomy for Parkinson's disease. N Engl J Med. (2020) 383:2501–13. doi: 10.1056/NEJMoa2016311

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Rezai AR, Ranjan M, D'Haese PF, Haut MW, Carpenter J, Najib U, et al. Noninvasive hippocampal blood-brain barrier opening in Alzheimer's disease with focused ultrasound. Proc Natl Acad Sci USA. (2020) 117:9180–2. doi: 10.1073/pnas.2002571117

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Lipsman N, Meng Y, Bethune AJ, Huang Y, Lam B, Masellis M, et al. Blood–brain barrier opening in Alzheimer's disease using MR-guided focused ultrasound. Nat Commun. (2018) 9:2336. doi: 10.1038/s41467-018-04529-6

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Mainprize T, Lipsman N, Huang Y, Meng Y, Bethune A, Ironside S, et al. Blood-brain barrier opening in primary brain tumors with non-invasive MR-guided focused ultrasound: a clinical safety and feasibility study. Sci Rep. (2019) 9:321. doi: 10.1038/s41598-018-36340-0

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Foley JL, Little JW, Vaezy S. Image-guided high-intensity focused ultrasound for conduction block of peripheral nerves. Ann Biomed Eng. (2007) 35:109–19. doi: 10.1007/s10439-006-9162-0

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Choi EJ, Choi YM, Jang EJ, Kim JY, Kim TK, Kim KH. Neural ablation and regeneration in pain practice. Korean J Pain. (2016) 29:3–11. doi: 10.3344/kjp.2016.29.1.3

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: MRgFUS, focused ultrasound (MRgFUS), HIFU, magnetic resonance-guided focused ultrasound surgery (MRgFUS), focused ultrasound (FUS)

Citation: Chazen JL, Sammartino F and Krishna V (2022) Editorial: Current state and future directions of cranial focused ultrasound therapy. Front. Neurol. 13:946634. doi: 10.3389/fneur.2022.946634

Received: 17 May 2022; Accepted: 01 July 2022;
Published: 18 July 2022.

Edited and reviewed by: Leonard Verhagen Metman, Rush University, United States

Copyright © 2022 Chazen, Sammartino and Krishna. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: J. L. Chazen, chazenjl@hss.edu

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.