AUTHOR=Mistral Thomas , Roca Pauline , Maggia Christophe , Tucholka Alan , Forbes Florence , Doyle Senan , Krainik Alexandre , Galanaud Damien , Schmitt Emmanuelle , Kremer Stéphane , Kastler Adrian , Troprès Irène , Barbier Emmanuel L. , Payen Jean-François , Dojat Michel TITLE=Automated Quantification of Brain Lesion Volume From Post-trauma MR Diffusion-Weighted Images JOURNAL=Frontiers in Neurology VOLUME=12 YEAR=2022 URL=https://www.frontiersin.org/journals/neurology/articles/10.3389/fneur.2021.740603 DOI=10.3389/fneur.2021.740603 ISSN=1664-2295 ABSTRACT=Objectives

Determining the volume of brain lesions after trauma is challenging. Manual delineation is observer-dependent and time-consuming and cannot therefore be used in routine practice. The study aimed to evaluate the feasibility of an automated atlas-based quantification procedure (AQP) based on the detection of abnormal mean diffusivity (MD) values computed from diffusion-weighted MR images.

Methods

The performance of AQP was measured against manual delineation consensus by independent raters in two series of experiments based on: (i) realistic trauma phantoms (n = 5) where low and high MD values were assigned to healthy brain images according to the intensity, form and location of lesion observed in real TBI cases; (ii) severe TBI patients (n = 12 patients) who underwent MR imaging within 10 days after injury.

Results

In realistic TBI phantoms, no statistical differences in Dice similarity coefficient, precision and brain lesion volumes were found between AQP, the rater consensus and the ground truth lesion delineations. Similar findings were obtained when comparing AQP and manual annotations for TBI patients. The intra-class correlation coefficient between AQP and manual delineation was 0.70 in realistic phantoms and 0.92 in TBI patients. The volume of brain lesions detected in TBI patients was 59 ml (19–84 ml) (median; 25–75th centiles).

Conclusions

Our results support the feasibility of using an automated quantification procedure to determine, with similar accuracy to manual delineation, the volume of low and high MD brain lesions after trauma, and thus allow the determination of the type and volume of edematous brain lesions. This approach had comparable performance with manual delineation by a panel of experts. It will be tested in a large cohort of patients enrolled in the multicenter OxyTC trial (NCT02754063).