AUTHOR=Schneider Sophie , Popp Werner L. , Brogioli Michael , Albisser Urs , Demkó László , Debecker Isabelle , Velstra Inge-Marie , Gassert Roger , Curt Armin TITLE=Reliability of Wearable-Sensor-Derived Measures of Physical Activity in Wheelchair-Dependent Spinal Cord Injured Patients JOURNAL=Frontiers in Neurology VOLUME=9 YEAR=2018 URL=https://www.frontiersin.org/journals/neurology/articles/10.3389/fneur.2018.01039 DOI=10.3389/fneur.2018.01039 ISSN=1664-2295 ABSTRACT=

Physical activity (PA) has been shown to have a positive influence on functional recovery in patients after a spinal cord injury (SCI). Hence, it can act as a confounder in clinical intervention studies. Wearable sensors are used to quantify PA in various neurological conditions. However, there is a lack of knowledge about the inter-day reliability of PA measures. The objective of this study was to investigate the single-day reliability of various PA measures in patients with a SCI and to propose recommendations on how many days of PA measurements are required to obtain reliable results. For this, PA of 63 wheelchair-dependent patients with a SCI were measured using wearable sensors. Patients of all age ranges (49.3 ± 16.6 years) and levels of injury (from C1 to L2, ASIA A-D) were included for this study and assessed at three to four different time periods during inpatient rehabilitation (2 weeks, 1 month, 3 months, and if applicable 6 months after injury) and after in-patient rehabilitation in their home-environment (at least 6 months after injury). The metrics of interest were total activity counts, PA intensity levels, metrics of wheeling quantity and metrics of movement quality. Activity counts showed consistently high single-day reliabilities, while measures of PA intensity levels considerably varied depending on the rehabilitation progress. Single-day reliabilities of metrics of movement quantity decreased with rehabilitation progress, while metrics of movement quality increased. To achieve a mean reliability of 0.8, we found that three continuous recording days are required for out-patients, and 2 days for in-patients. Furthermore, the results show similar weekday and weekend wheeling activity for in- and out-patients. To our knowledge, this is the first study to investigate the reliability of an extended set of sensor-based measures of PA in both acute and chronic wheelchair-dependent SCI patients. The results provide recommendations for sensor-based assessments of PA in clinical SCI studies.