AUTHOR=Shahdloo Mo , Khalighinejad Nima , Priestley Luke , Rushworth Matthew , Chiew Mark TITLE=Dynamic off-resonance correction improves functional image analysis in fMRI of awake behaving non-human primates JOURNAL=Frontiers in Neuroimaging VOLUME=3 YEAR=2024 URL=https://www.frontiersin.org/journals/neuroimaging/articles/10.3389/fnimg.2024.1336887 DOI=10.3389/fnimg.2024.1336887 ISSN=2813-1193 ABSTRACT=Introduction

Use of functional MRI in awake non-human primate (NHPs) has recently increased. Scanning animals while awake makes data collection possible in the absence of anesthetic modulation and with an extended range of possible experimental designs. Robust awake NHP imaging however is challenging due to the strong artifacts caused by time-varying off-resonance changes introduced by the animal's body motion. In this study, we sought to thoroughly investigate the effect of a newly proposed dynamic off-resonance correction method on brain activation estimates using extended awake NHP data.

Methods

We correct for dynamic B0 changes in reconstruction of highly accelerated simultaneous multi-slice EPI acquisitions by estimating and correcting for dynamic field perturbations. Functional MRI data were collected in four male rhesus monkeys performing a decision-making task in the scanner, and analyses of improvements in sensitivity and reliability were performed compared to conventional image reconstruction.

Results

Applying the correction resulted in reduced bias and improved temporal stability in the reconstructed time-series data. We found increased sensitivity to functional activation at the individual and group levels, as well as improved reliability of statistical parameter estimates.

Conclusions

Our results show significant improvements in image fidelity using our proposed correction strategy, as well as greatly enhanced and more reliable activation estimates in GLM analyses.