Skip to main content

ORIGINAL RESEARCH article

Front. Mol. Biosci., 26 October 2021
Sec. Metabolomics
This article is part of the Research Topic OMICS-Based Approaches in Sports Research View all 9 articles

Integrating Whole Blood Transcriptomic Collection Procedures Into the Current Anti-Doping Testing System, Including Long-Term Storage and Re-Testing of Anti-Doping Samples

  • 1Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Rome, Italy
  • 2School of Sport and Health Sciences, University of Brighton, Eastbourne, United Kingdom
  • 3Centre for Stress and Age Related Disease, University of Brighton, Brighton, United Kingdom
  • 4School of Applied Sciences, University of Brighton, Brighton, United Kingdom
  • 5Department of Biophysics, Federal University of Sao Paulo, Sao Paulo, Brazil
  • 6McKusick-Nathans Department of Genetic Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States
  • 7Sport and Exercise Science and Sports Medicine Research and Enterprise Group, University of Brighton, Brighton, United Kingdom
  • 8Anti-Doping Lab Qatar, Doping Analysis Lab, Doha, Qatar
  • 9NADO Italia, National Antidoping Organization, Rome, Italy
  • 10International Federation of Sports Medicine (FIMS), Lausanne, Switzerland

Introduction: Recombinant human erythropoietin (rHuEPO) administration studies involving transcriptomic approaches have demonstrated a gene expression signature that could aid blood doping detection. However, current anti-doping testing does not involve collecting whole blood into tubes with RNA preservative. This study investigated if whole blood in long-term storage and whole blood left over from standard hematological testing in short-term storage could be used for transcriptomic analysis despite lacking RNA preservation.

Methods: Whole blood samples were collected from twelve and fourteen healthy nonathletic males, for long-term and short-term storage experiments. Long-term storage involved whole blood collected into Tempus™ tubes and K2EDTA tubes and subjected to long-term (i.e., ‒80°C) storage and RNA extracted. Short-term storage involved whole blood collected into K2EDTA tubes and stored at 4°C for 6‒48 h and then incubated at room temperature for 1 and 2 h prior to addition of RNA preservative. RNA quantity, purity, and integrity were analyzed in addition to RNA-Seq using the MGI DNBSEQ-G400 on RNA from both the short- and long-term storage studies. Genes presenting a fold change (FC) of >1.1 or < ‒1.1 with p ≤ 0.05 for each comparison were considered differentially expressed. Microarray analysis using the Affymetrix GeneChip® Human Transcriptome 2.0 Array was additionally conducted on RNA from the short-term study with a false discovery ratio (FDR) of ≤0.05 and an FC of >1.1 or < ‒1.1 applied to identify differentially expressed genes.

Results: RNA quantity, purity, and integrity from whole blood subjected to short- and long-term storage were sufficient for gene expression analysis. Long-term storage: when comparing blood tubes with and without RNA preservation 4,058 transcripts (6% of coding and non-coding transcripts) were differentially expressed using microarray and 658 genes (3.4% of mapped genes) were differentially expressed using RNA-Seq. Short-term storage: mean RNA integrity and yield were not significantly different at any of the time points. RNA-Seq analysis revealed a very small number of differentially expressed genes (70 or 1.37% of mapped genes) when comparing samples stored between 6 and 48 h without RNA preservative. None of the genes previously identified in rHuEPO administration studies were differently expressed in either long- or short-term storage experiments.

Conclusion: RNA quantity, purity, and integrity were not significantly compromised from short- or long-term storage in blood storage tubes lacking RNA stabilization, indicating that transcriptomic analysis could be conducted using anti-doping samples collected or biobanked without RNA preservation.

Introduction

The World Anti-Doping Agency (WADA) was created in 1999 and has been at the forefront of anti-doping ever since (Ljungqvist, 2017). Over the years, numerous testing methods and strategies have been developed to improve the efficiency of the anti-doping system with some success, thanks to advances in analytical technologies (Thevis et al., 2021). However, the efficiency of the current system remains inadequate as the number of true doping cases vastly exceeds those detected (de Hon et al., 2014; Faiss et al., 2020). In response to this situation and to take advantage of advances in analytical techniques over the last few decades, WADA introduced the capacity for anti-doping samples to be stored for the long term (initially 8 years, but currently 10 years) for retrospective re-analysis as new technologies and approaches emerge (Kuuranne and Saugy, 2016). Subsequently, the majority (74%) of Anti-Doping Rule Violations that have impacted medal-winning results at the Summer Olympic Games, from 1968 to 2012, have been identified retrospectively (Kolliari-Turner et al., 2021). Thereby, it has been argued that in addition to increasing pre-Olympic out-of-competition testing to avoid retrospective analysis to identify doping in the first place, long-term sample storage should continue and additionally incorporate novel and potentially complementary technologies/sample matrices (Kolliari-Turner et al., 2021).

The continued success of the storage and re-analysis program is predicated on the inclusion of new technologies as these become available. For example, next-generation sequencing and “omics”-based technologies are increasingly being used in clinical testing, scientific research, and disease diagnoses, including cancer, with immense success (Kaczor-Urbanowicz et al., 2017; Schmidt et al., 2021). It is anticipated that multi-omics approaches will, in time, be integrated into current biomarker assessment (International Olympic Committee, 2019). However, adoption of these omics-based methods for anti-doping purposes will require the appropriate storage of samples such as blood, urine, and saliva into specific preservatives (Beekman et al., 2009; Kaczor-Urbanowicz et al., 2017), which, until presently, was not being planned. This is despite the fact that the first studies emerged more than a decade ago, showing great potential for omics strategies and methods to improve anti-doping testing by discovering indirect doping biomarkers and analyzing biological changes induced by performance-enhancing drugs (PEDs) (Reichel, 2011; Saugy et al., 2011). These first studies of gene expression analysis in whole blood samples collected following recombinant human erythropoietin (rHuEPO) administration revealed a characteristic gene expression signature with important implications for rHuEPO doping detection (Durussel et al., 2016; Wang et al., 2017a). These studies, interpreted in the context of “omics” applications in the field of biomedical sciences (Karczewski and Snyder, 2018), reveal that it is only a matter of when, rather than if, these omics-based methods will become regularly used in anti-doping science, highlighting the importance for appropriate storage of samples for analysis using these methods when they become available. However, whole blood samples currently collected for anti-doping purposes (WADA, 2021a), such as K2EDTA tubes, do not contain RNA stabilizing reagents. Once collected, the whole blood samples are sealed in tamper-proof containers, stored upright in a refrigerated state, dispatched with a temperature data logger to the laboratory, and analyzed within 72 h from collection (WADA, 2021b). As such, whole blood samples are collected/stored in conditions that may not prevent RNA degradation, and therefore, it is unknown whether the degradation of RNA transcripts could confound subsequent transcriptomic analysis (Gallego Romero et al., 2014). Importantly, the implementation/integration of transcriptomic technologies into the current anti-doping system should use the same methodology as that used in the discovery and validation studies (Durussel et al., 2016; Wang et al., 2017a); when this is not possible, an adaptive protocol should be developed and validated. This study has two aims: 1) to study if whole blood collected into K2EDTA tubes and subjected to long-term storage (i.e., −80°C storage, to simulate biobanking of K2EDTA tubes) could impact transcriptomic analysis and 2) to investigate if whole blood collected into K2EDTA tubes and stored for up to 48 h at 4°C, to simulate short-term storage, could impact transcriptomic analysis, to see if leftover blood from standard hematological testing could be preserved and then used for this purpose.

Materials and Methods

The study designs and collection procedures were explained to all participants who provided informed consent. The local ethics committee (long-term storage: SSCREC 2016–28; short-term storage: SSCREC17-32) approved the study designs, and all collection procedures were carried out according to the Helsinki Declaration. Blood samples were collected by trained phlebotomists.

Experimental Design—Long-Term Storage

The long-term storage study was designed considering the following: 1) the ideal situation (RNA collection/extraction according to manufacturer instructions) as a reference and 2) the real situation that is faced by anti-doping biobanks, where whole blood samples are stored in tubes without an RNA stabilization reagent (e.g., K2EDTA tubes).

Sample Collection and Storage

Whole blood was collected from an antecubital vein using a closed vacuette system from 12 male nonathletes (age: 23.9 ± 3.2; weight (kg): 80.0 ± 13.4; body fat percentage: 12.5 ± 2.9). A 3 mL whole blood sample was collected into a Tempus™ Blood RNA Tube (Life Technologies, Carlsbad, CA, United States), and a 10-mL whole blood sample was collected into a BD® EDTA tube (K2EDTA, Plymouth, United Kingdom). Immediately after collection, the Tempus™ tubes were vigorously shaken for 10 s and incubated at room temperature (RT) for ∼3 h and then stored at −80°C before subsequent analysis. After collection, the K2EDTA tube was gently inverted 10 times, incubated at 4°C for 1–4 h and then stored at −80°C for further analyses. During the 4°C incubation period for the K2EDTA tube, 1.25 mL of blood was pipetted into aliquots of 250 µL into five separate 1.5 mL TubeOne® Microcentrifuge tubes (Starlab, Milton Keynes, United Kingdom). One of these aliquots was used for RNA extraction from a “fresh” blood sample, and the other four tubes were immediately stored at −80°C.

RNA Extraction

Total RNA was extracted from whole blood using two protocols: 1) the Tempus™ Spin RNA Isolation Kit (Life Technologies, Carlsbad, CA, United States) and 2) the GeneJET RNA Purification Kit (Thermo Fisher Scientific, Vilnius, Lithuania) following manufacturer instructions (User Guide, 2019a; User Guide, 2019b). The Tempus™ kit was chosen because it has been used in our previous studies (Durussel et al., 2016; Wang et al., 2017a) and as such facilitates comparability with previous results. The GeneJET kit was chosen because it is specific to extracting RNA from low volumes of frozen blood. In addition, both protocols were adapted for frozen blood samples that were collected/stored using K2EDTA tubes. The remaining blood sample inside the 10 mL K2EDTA tube was thawed on ice for ∼1.5 h, and then 3 mL of whole blood was used to perform the Tempus™ protocol and 250 µL was used for the GeneJET protocol. Considering the manufacturer and adapted protocols, RNA extraction was performed using five different protocol designs (Figure 1). After extraction, all RNA samples were stored at −80°C until further analysis.

FIGURE 1
www.frontiersin.org

FIGURE 1. Long-term storage study design to evaluate RNA integrity and quality of samples collected in K2EDTA or Tempus™ blood tubes that have been kept at −80°C. Ideal situation: GJ_fresh: collected using a K2EDTA tube, incubated at 4°C (for up to 4 h), and extracted using the GeneJET protocol; Temp: collected/stored/extracted following the standard Tempus™ protocol; GJ_aliq: collected using a K2EDTA tube; a 250-µL aliquot is taken and stored in a 1.5-mL Microcentrifuge tube (according to manufacturer instructions) and then thawed with 250 µl of kit buffer and extracted using the GeneJET protocol. Real situation: EDTA + Temp: collected/stored using a K2EDTA tube, stored at −80°C, and thawed on ice; then 3 mL of whole blood was pipetted into a Tempus™ tube, vigorously shaken for 10 s, incubated at RT (∼3 h), and then extracted using the Tempus protocol; EDTA + GJ: collected/stored using a K2EDTA tube, stored at –80°C, and thawed on ice; next, 250 µl of whole blood was pipetted into a 1.5-mL Microcentrifuge tube and then extracted using the GeneJET protocol.

RNA Quality and Purity Analysis

RNA quantity and purity were assessed using a Nanodrop® ND-2000 Spectrophotometer (Thermo Fisher Scientific, Waltham, MA, United States). RNA integrity (RIN, RNA integrity number) was assessed using an Agilent® 2100 Bioanalyzer with an Agilent® RNA 6000 Nano Kit (Agilent Technologies, Santa Clara, CA, United States).

RNA Microarray Analysis

RNA samples of 8 subjects from four different storage/extraction protocols (Temp, EDTA + Temp, GJ_aliq, and EDTA + GJ) with the highest quality were selected for the following analysis (GJ_fresh was not included because this did not simulate using frozen/biobanked samples nor was it used in previous studies with anti-doping purposes). One hundred nanograms of purified total RNA was processed using the Affymetrix GeneChip® Human Transcriptome 2.0 Array and a GeneChip® WT Plus Reagent Kit according to manufacturer instructions (Affymetrix, Thermo Fisher Scientific, Waltham, MA, United States). Transcriptome Analysis Console (TAC) 4.0 software (Life Technologies, Carlsbad, CA, United States) performed initial data QC, visualization of array scanning data, and transcript expression analysis. A false discovery ratio (FDR) of ≤0.05 and a fold change of >1.1 or <–1.1 were applied. The ideal situations were considered as reference groups.

RNA-Sequencing

Seven RNA samples with the highest RIN values from each of the groups Temp and EDTA + Temp were selected for RNA-Seq analysis. rRNA was depleted from 200 ng of purified total RNA with RIN ≥7 using an MGIEasy rRNA Depletion Kit (BGI, Shenzhen, China). dsDNA libraries (with conditions for a 250-bp Insert Size) were created from the rRNA-depleted eluate using an MGIEasy RNA Directional Library Prep Set. dsDNA library quantity was assessed using a Thermo Fisher Scientific Qubit® dsDNA High Sensitivity Assay Kit and a Qubit® Fluorometer (Thermo Fisher Scientific, Waltham, MA, United States). The quality of the fragment size distribution of the dsDNA library was assessed by visual inspection of electropherograms created using an Agilent® DNA 1000 Kit on an Agilent® 2100 Bioanalyzer. Only dsDNA libraries with satisfactory fragment size distributions were carried forward onto the next steps, and dsDNA libraries were re-created for any samples with aberrant electropherograms or low concentrations. dsDNA libraries were circularized and converted into ssDNA libraries using an MGIEasy Circularization Kit. ssDNA library concentration was assessed using a Thermo Fisher Scientific Qubit® ssDNA Assay Kit and a Qubit® Fluorometer. DNA nanoballs (DNBs) were prepared from the ssDNA library pools, with a 40-fmol ssDNA library for each reaction, using an MGI DNBSEQ-G400RS High-throughput Sequencing Set (BGI, Shenzhen, China). DNB concentration was assessed using a Thermo Fisher Scientific Qubit® ssDNA Assay Kit and a Qubit® Fluorometer. DNB preparations >8 ng/μL were loaded onto two flow cells (containing equal numbers of samples) using an MGIDL-200H Portable DNB Loader (BGI, Shenzhen, China). The flow cells were placed on an MGI DNBSEQ-G400 sequencer (BGI, Shenzhen, China) and subjected to PE100 sequencing.

RNA-Sequencing Gene Expression Analysis

Reads were mapped to Human Genome GRCh37 reference (hg19) using STAR 2.5.3. Gene counts were obtained using an annotation model based on RefSeq Transcripts (release 96) and normalized by fragments per kilobase million (FPKM) and by adding 0.0001 to all read counts, to allow statistical testing. Differential gene expression was determined by Partek Gene Set Analysis (GSA) using default settings. Genes presenting a fold change >1.1 or <–1.1 (a FC of 1.1) with p ≤ 0.05 for each comparison were considered differentially expressed.

Experimental Design—Short-Term Storage

Only one participant from the long-term storage study also took part in the short-term storage study, and sampling was separated by > 12 months. Whole blood was collected from an antecubital vein of 14 male nonathletes, using a closed vacuette system in four separate 3-mL K2EDTA tubes. After collection, each of the four tubes was stored at 4°C for 6, 12, 24, or 48 h. At each of these time points, one of the K2EDTA tubes was removed from 4°C and maintained at RT for a total of 60 min to simulate the time required for sample registration and analysis. For the first 15 min of these 60 min at RT, the tube was placed in a sample mixer, and for the remaining 45 min, the tube remained upright at RT. After 60 min, 1.5 mL of whole blood was then removed from the tube and added to a new tube containing 3 mL of Tempus™ Blood RNA preservative, and this tube was shaken vigorously for 10 s. After a final 2 h at RT, the remaining 1.5 mL of whole blood was added to 3 mL of Tempus™ Blood RNA stabilizing reagent in a different tube, and this was shaken vigorously for 10 s. This was to simulate an extended registration and analysis time as can potentially occur in big events with a very high number of samples. All samples were then stored at −80°C until RNA extraction. The experimental design is illustrated in Figure 2.

FIGURE 2
www.frontiersin.org

FIGURE 2. Short-term storage study design to evaluate RNA integrity and quality of samples collected and stored in K2EDTA tubes and then incubated at RT.

RNA Extraction and Quantification

Total RNA was extracted from whole blood using a Tempus™ Spin RNA Isolation Kit (Life Technologies, Carlsbad, CA, United States) following manufacturer instructions (User Guide, 2019b). RNA quality and purity were assessed as described in the long-term storage study methods section.

RNA-Sequencing

Four samples, with the highest RIN value from each of the four time points (6, 12, 24, and 48 h spent incubating at 4°C), which were all incubated at RT for 1 h prior to the addition of RNA preservative, were selected for RNA-Seq and analyzed as described above in the long-term storage study methods section.

Statistical Analysis

Descriptive data were presented as mean values and standard deviation (SD). The difference of integrity and purity values between the groups was determined using a generalized linear model, corrected by Bonferroni post hoc. The analyses of RNA quantity and quality were performed using SPSS software (v.23) with alpha at p ≤ 0.05.

Results

Long-Term Storage

The average RNA yield of the Tempus™ extraction kit was higher than that of the GeneJET kit (Figure 3A). There were no statistical differences for the mean RIN of groups within the ideal situation. The ideal situation groups had a significantly higher mean RIN than the real situation groups. In addition, EDTA + Temp had a statistically significant higher mean RIN than EDTA + GJ (Figure 3C). RNA purity was analyzed using two absorbance ratios (A260/280 and A260/230). All groups demonstrated A260/280 > 2, with statistical differences between Temp and GJ_fresh (Figure 3D). Therefore, there was no significant difference in the comparison of A260/230 between the Tempus™ and GeneJET kits, although this difference was statistically significant in the inter-group comparisons (Figure 3D) (see values of the mean and comparison in Supplementary Material S1).

FIGURE 3
www.frontiersin.org

FIGURE 3. Yield (A), relative yield (B), RIN (C), and absorbance ratio (D) of RNA extracted from whole blood samples using the five different protocols. RIN, RNA integrity number; Temp, Tempus protocol; EDTA + Temp, K2EDTA tube plus Tempus protocol; GJ_aliq, GeneJET aliquoted protocol; EDTA + GJ, K2EDTA tube plus GeneJET protocol; GJ_fresh, Fresh blood and GeneJET protocol. The relative yield was reached by multiplying the final value of GeneJET protocol RNA extraction by 12 (as the starting volume is 12-fold lower than that of the Tempus protocol); * = p ≤ 0.05; ** = p ≤ 0.001. The graphs show mean values ±SD.

Principal component analysis (PCA) (Figure 4) of microarray data demonstrated a separation between ideal situation groups and real situation groups and a lower difference intra-kit (EDTA + Temp vs. Temp and EDTA + GJ vs. GJ_aliq) than inter-kit (GJ_aliq vs. Temp). The comparison between EDTA + Temp vs. Temp showed the lowest number of differentially expressed transcripts (n = 4,058, which means 6.01% of the 67,528 coding and non-coding transcripts analyzed using the microarray), while EDTA + GJ vs. GJ_aliq demonstrated 6,324 (9.37%) and GJ_aliq vs. Temp revealed 13,678 (20.26%) differentially expressed transcripts.

FIGURE 4
www.frontiersin.org

FIGURE 4. Microarray gene expression analysis. PCA, principal component analysis; Temp, Tempus protocol; EDTA + Temp, K2EDTA tube plus Tempus protocol; GJ_aliq, GeneJET aliquoted protocol; EDTA + GJ, K2EDTA tube plus GeneJET protocol.

The PCA of RNA-Seq data comparing Temp and EDTA + Temp also showed two clusters, according to the sampling tube (Figure 5). The gene expression analysis showed that 658 genes were differentially expressed (which means 3.4% of mapped genes), with 269 being upregulated and 389 downregulated (list of differentially expressed transcripts in Supplementary Material S2). None of the transcripts described in previous studies relating to rHuEPO doping (Durussel et al., 2016; Wang et al., 2017a) were differently expressed.

FIGURE 5
www.frontiersin.org

FIGURE 5. RNA-Seq gene expression analysis. PCA, principal component analysis; Temp, Tempus protocol; EDTA + Temp, K2EDTA tube plus Tempus protocol.

Short-Term Storage Results

There were no statistical differences for the mean RIN and yield amongst all eight time points (Figures 6A,B). When comparing all samples that were incubated at RT for 1 or 2 h, the RNA yield of 1 h incubation was significantly higher (3,539.8 ± 1,291.2 vs. 2,506.3 ± 911.5 ng, p ≤ 0.05).

FIGURE 6
www.frontiersin.org

FIGURE 6. Yield (A), RIN (B), absorbance ratio 260/280 (C), and absorbance ratio 260/230 (D) of RNA extracted from samples stored at 4°C for 6, 12, 24, and 48 h, followed by 1 h (0.1) or 2 h (0.2) at room temperature. RIN, RNA integrity number.

A260/280 did not present differences among time points (Figure 6C). A260/230 revealed a significantly higher mean of the time points 6 h at 4°C and 2 h at RT compared to 6 and 24 h at 4°C and 1 h at RT (2.75 ± 0.4 vs. 2.41 ± 0.18 and 2.35 ± 0.16, p ≤ 0.05, respectively) (Figure 6D).

RNA-Seq was conducted on four participants’ samples, with each sample having a 1 h RT incubation at each time point (i.e., 6, 12, 24, and 48 h; n = 16 samples in total). PCA did not demonstrate clear clusters regarding time of storage but did show clusters regarding samples of the same subjects (Figure 7). With 6 h storage as a reference group, the number of differentially expressed genes was 19, 45, and 70 in comparison to 12, 24, and 48 h, respectively (which means 0.37, 0.88, and 1.37% of mapped genes). Of the 19 differentially expressed genes in the comparison of 6 vs. 12 h, 9 overlapped with the 45 in the comparison of 12 vs. 24 h. Furthermore, 40 of those 45 overlapped with the 70 differentially expressed in the comparison of 6 vs. 48 h (list of differentially expressed genes in Supplementary Material S3). Again, none of the transcripts described in previous studies relating to rHuEPO doping (Durussel et al., 2016; Wang et al., 2017a) were differently expressed.

FIGURE 7
www.frontiersin.org

FIGURE 7. RNA-Seq gene expression analysis. PCA, principal component analysis; Dot Colors, sample ID; Frame lines, time.

Discussion

PED usage can create a gene expression signature, and transcriptomic analysis of these signatures can be a powerful tool to improve the anti-doping testing system (Reichel, 2011; Pitsiladis et al., 2014; Wang et al., 2017b). However, there are many requirements for the implementation and validation of this method to consider it for the current anti-doping system. RNA quality and quantity are of paramount importance to accurate gene expression analyses. Therefore, the choice of extraction protocol is a crucial step for downstream outcomes. Currently, anti-doping blood samples are not collected into tubes that contain RNA preservatives, whereas an appropriate RNA collection blood tube was used in rHuEPO gene expression discovery studies (Durussel et al., 2016; Wang et al., 2017a). This present study aimed to design a protocol to enable the comparison of current anti-doping sampling and storage methods with previous anti-doping gene expression signature studies and, additionally, see if long-term stored anti-doping samples could potentially be used for gene expression analysis.

In the long-term storage study, the results showed that both methods (i.e., Tempus™ and GeneJET) extracted sufficient RNA quantities from blood collected in a K2EDTA tube and stored at −80°C. The standard Tempus™ protocol provided noticeably higher yield (Figure 3A); however, it does not mean better efficiency, due to the lower starting sample volume of the GeneJET protocol (3 mL vs. 250 µL). Both Tempus™ and GeneJET extraction kits produced RNA with a mean absorbance ratio (A260/280) > 2 (Figure 3D), which is considered “pure” for further RNA applications (NanoDrop, 2009). Although GJ_fresh had a statistically higher mean than Temp, in practice, this difference might not be relevant as both values are sufficiently high. A260/230 can indicate the presence of co-purified contaminants (such as carbohydrates and salts) if this ratio presents a value lower than 1.8 (Lee et al., 2014). Samples extracted using a Tempus™ kit showed mean values higher than 2.2 while GeneJET extraction demonstrated statistically lower values (on average, ≤1.8). Although the Tempus™ kit did show a better result for this parameter, the impact of this difference on downstream analyses is not clear.

RNA integrity was evaluated according to the RIN value (numeric scale from 1 to 10, where 1 means the most degraded and 10 means the most intact profile (Mueller et al., 2004)). The RIN value demonstrated that ideal situation groups (following manufacturer instructions) had significantly higher mean values than the real situation groups (adapted protocol) (Figure 3C). In the adapted protocol, the blood samples inside K2EDTA tubes were thawed on ice for ∼1.5 h, followed by the RNA extraction protocol. This thawing time could affect RNA integrity as mRNA structures could be degraded by RNase enzymes (Swift et al., 2000). Nevertheless, the average RIN values were considered acceptable (Fleige and Pfaffl, 2006; Beekman et al., 2009). Of note is that a PCA plot of microarray data (Figure 4) shows that expression profiles are more similar for samples that are extracted using the same manufacturer kit. This result can also be observed for the number of differentially expressed transcripts when EDTA + Temp and Temp were compared. A PCA plot generated by RNA-Seq analysis also discriminated between the Temp and EDTA + Temp clusters, as well as 658 genes differentially expressed. Considering the application of transcriptomic-based technologies in order to improve the efficacy of doping detection, we analyzed 49 target and five housekeeping (HK) genes described in previous studies (Wang et al., 2017a) (list of genes in Supplementary Material S4). None of the target and HK genes were differentially expressed in the comparison of EDTA + Temp vs. Temp, which could suggest that target genes and their controls were not impacted by the freezing/thawing process and could be used as doping biomarkers in biobanked samples. Some of these genes (ALAS2, CA1, and SLC4A1) have already been shown to be promising blood doping biomarkers even when using blood samples collected by Dried Blood Spot (DBS) technologies (Salamin et al., 2019; Loria et al., 2020)”. The expression of blood transcriptomic biomarkers remains significantly different after 3 days using DBS blood samples (Loria et al., 2020) and up to 3 weeks after using whole blood collected using TempusTM tubes (Wang et al., 2017a). ALAS2 is a tissue-specific gene and plays an important role in heme biosynthesis, providing instructions for the expression of an enzyme called 5′-aminolevulinate synthase 2 or erythroid ALA-synthase, found only in erythroblasts. Therefore, ALAS2 is mediated by erythroid-specific factors and has an impact on hemoglobin formation (Ajioka et al., 2006; Wang et al., 2017a). Carbonic anhydrases (CAs) are metalloenzymes that catalyze the important interconversion between CO2 and bicarbonate and are involved in many physiological and pathological processes such as respiration and CO2 transport, pH and CO2 homeostasis, biosynthetic reactions, calcification, and tumor progression (Kupriyanova et al., 2017). SLC4A1 encodes a protein member of the Solute Carrier 4 family of bicarbonate transporters (SLC4A1), which is expressed in the erythrocyte membrane, involved in the transport of carbon dioxide from tissues to the lungs (Reithmeier et al., 2016).

The short-term storage experiments were designed based on the observed logistics of sample collection, storage, transport, registration, and analysis of anti-doping samples during anti-doping testing performed at the IAAF World Championships 2019 in Doha, Qatar. WADA Code guidelines describe that for the analysis of Prohibited Substances and Methods, two blood samples should be collected from an athlete (samples A and B) in two 3-mL K2EDTA tubes (WADA, 2021c). Blood samples are dispatched as soon as possible after collection to an anti-doping laboratory and analyzed within 72 h from collection (WADA, 2021c). During the IAAF World Championships 2019, all samples were analyzed between 6 and 24 h after collection. WADA guidelines also require a sample to be mixed thoroughly for a minimum period of 15 min at room temperature using an appropriate mixer (e.g., roller mixer) prior to analysis once the tube is removed from the tamper-proof container. Recently, the Sysmex XN-1000 automated hematology analyzer has been introduced as the hematology analyzer of choice for all WADA-accredited and approved laboratories (WADA, 2021b; XN, 2021). Each blood sample analyzed using the Sysmex XN-1000 must be analyzed twice, and the results of the second sample are used to confirm those of the first; if the difference between both is above the accepted criteria, the analysis is repeated. Due to that process, blood samples can remain at RT for 1 or 2 h. The Sysmex XN-1000 aspirates 88 µL of whole blood for each single analysis (XN, 2021), and once the duplicate result is within the limits, the result is accepted (WADA, 2021a). After this analysis, the remaining volume of whole blood could be used for gene expression analysis as shown in Figure 8. To fit in this context, the short-term storage experiment was designed to investigate if the storage protocol that these remaining whole blood samples collected into K2EDTA tubes would be subjected to would impact RNA quality, purity, integrity, and transcriptomic analysis. Unexpectedly, the RIN value of the samples was not significantly different between all the time points, and neither was the RNA yield. However, comparing all samples at RT for 1 h vs. 2 h, the yield was significantly lower in 2 h groups but still sufficiently high for RNA-Seq. RNA-Seq analysis demonstrated that the number of differentially expressed genes increases the longer the sample is stored at 4°C prior to the addition of RNA preservative. However, none of the gene targets described in the gene expression signature of rHuEPO administration (Wang et al., 2017a) (list of genes in Supplementary Material S4) presented different expression in the short-term storage study. The low number of transcripts differently expressed across time of storage, including the absence of blood doping transcript targets, supports the possible integration of gene expression collection procedures and analytical methods into samples left over from routine hematological anti-doping testing.

FIGURE 8
www.frontiersin.org

FIGURE 8. Proposed pipeline for integration of gene expression analysis into the current anti-doping collection protocols, using TempusTM tubes to preserve RNA integrity.

The short-term storage experiment showed that 1.5 mL of whole blood collected in K2EDTA, simulating remaining blood from standard hematological testing, could be used for extracting RNA that has sufficient yield, quality, and integrity for gene expression analyses. The long-term storage experiment also demonstrated that 3 mL whole blood collected in K2EDTA tubes and stored at −80°C can be used for gene expression analysis. In both of the studies, none of the gene targets described in the gene expression signature of rHuEPO administration (Wang et al., 2017a) presented different expression. In summary, despite many challenges, the results of this study are very encouraging and reveal that RNA yield and purity are not compromised and that significant progress has been made toward how to integrate these new transcriptomic tests into the current anti-doping testing system, including using samples remaining from standard hematological testing. The limitations of the present study include the use of a nonathlete population, and although the sample collection procedures tried to simulate the International Standard for Laboratories (ISL) protocols, the samples were not collected in a real anti-doping testing situation. Future studies with a higher number of participants/samples, including known doped blood samples in the aforementioned situations, can give more support to the validation of the protocols designed in the present study.

Data Availability Statement

The data presented in the study are deposited in the Gene Expression Omnibus (GEO) repository, accession numbers; Microarray: GSE181970 and RNA-Seq (unified): GSE183133, or in these links: microarray: https://www.ncbi.nlm.nih.gov/geo/query/acc.cgi?acc=GSE181970, RNA-Seq: https://www.ncbi.nlm.nih.gov/geo/query/acc.cgi?acc=GSE183133.

Ethics Statement

This study involved human participants and was reviewed and approved by the University of Brighton ethics committee. The participants provided informed consent to participate in this study.

Author Contributions

GL and YP conceptualized the study. FM, GL, GW, and SV designed the study. AK-T and GL collected the samples. AK-T, GL, and GW carried out the experiments. GL and RM analyzed the data. GL wrote the initial draft of the article. All authors critically evaluated and approved the final version of the article.

Funding

This research was supported by a research grant from the International Olympic Committee.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors, and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Acknowledgments

The authors would like to thank all volunteers for their participation and cooperation.

Supplementary Material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fmolb.2021.728273/full#supplementary-material

References

Ajioka, R. S., Phillips, J. D., and Kushner, J. P. (2006). Biosynthesis of heme in mammals. Biochim. Biophys. Acta (Bba)–Mol. Cel. Res. 1763, 723–736. doi:10.1016/j.bbamcr.2006.05.005

PubMed Abstract | CrossRef Full Text | Google Scholar

Beekman, J. M., Reischl, J., Henderson, D., Bauer, D., Ternes, R., Peña, C., et al. (2009). Recovery of microarray-quality RNA from frozen EDTA blood samples. J. Pharmacol. Toxicol. Methods 59, 44–49. doi:10.1016/j.vascn.2008.10.003

PubMed Abstract | CrossRef Full Text | Google Scholar

de Hon, O., Kuipers, H., and van Bottenburg, M. (2014). Prevalence of Doping Use in Elite Sports: A Review of Numbers and Methods. Sports Med. 45, 57–69. doi:10.1007/s40279-014-0247-x

CrossRef Full Text | Google Scholar

Durussel, J., Haile, D. W., Mooses, K., Daskalaki, E., Beattie, W., Mooses, M., et al. (2016). Blood transcriptional signature of recombinant human erythropoietin administration and implications for antidoping strategies. Physiol. Genomics 48, 202–209. doi:10.1152/physiolgenomics.00108.2015

PubMed Abstract | CrossRef Full Text | Google Scholar

Faiss, R., Saugy, J., Zollinger, A., Robinson, N., Schuetz, F., Saugy, M., et al. (2020). Prevalence Estimate of Blood Doping in Elite Track and Field Athletes During Two Major International Events. Front. Physiol. 11, 1–11. doi:10.3389/fphys.2020.00160

PubMed Abstract | CrossRef Full Text | Google Scholar

Fleige, S., and Pfaffl, M. W. (2006). RNA integrity and the effect on the real-time qRT-PCR performance. Mol. Aspects Med. 27, 126–139. doi:10.1016/j.mam.2005.12.003

PubMed Abstract | CrossRef Full Text | Google Scholar

Gallego Romero, I., Pai, A. A., Tung, J., and Gilad, Y. (2014). RNA-seq: Impact of RNA degradation on transcript quantification. BMC Biol. 12, 42–13. doi:10.1186/1741-7007-12-42

PubMed Abstract | CrossRef Full Text | Google Scholar

International Olympic Committee (2019). IOC President Speech 5th World Conference on Doping in Sport Katowice, Poland, 5 November 2019. Available at: www.olympic.org/-/media/Document Library/OlympicOrg/News/2019/11/World-Conference-on-Doping.pdf.

Google Scholar

Kaczor-Urbanowicz, K. E., Martin Carreras-Presas, C., Aro, K., Tu, M., Garcia-Godoy, F., and Wong, D. T. (2017). Saliva diagnostics - Current views and directions. Exp. Biol. Med. (Maywood) 242, 459–472. doi:10.1177/1535370216681550

PubMed Abstract | CrossRef Full Text | Google Scholar

Karczewski, K. J., and Snyder, M. P. (2018). Integrative omics for health and disease. Nat. Rev. Genet. 19, 299–310. doi:10.1038/nrg.2018.4

PubMed Abstract | CrossRef Full Text | Google Scholar

Kim, J.-H., Jin, H.-O., Park, J.-A., Chang, Y. H., Hong, Y. J., and Lee, J. K. (2014). Comparison of three different kits for extraction of high-quality RNA from frozen blood. Springerplus 3, 76. doi:10.1186/2193-1801-3-76

PubMed Abstract | CrossRef Full Text | Google Scholar

Kolliari-Turner, A., Lima, G., Hamilton, B., Pitsiladis, Y., and Guppy, F. M. (2021). Analysis of Anti-Doping Rule Violations that Have Impacted Medal Results at the Summer Olympic Games 1968-2012. Sports Med., 1–9. doi:10.1007/s40279-021-01463-4

CrossRef Full Text | Google Scholar

Kupriyanova, E., Pronina, N., and Los, D. (2017). Carbonic anhydrase - a universal enzyme of the carbon-based life. Photosynt. 55, 3–19. doi:10.1007/s11099-017-0685-4

CrossRef Full Text | Google Scholar

Kuuranne, T., and Saugy, M. (2016). Retesting the anti-doping samples: Best tool for deterrence? Schweizerische Z. Sport Sport 64, 19–22. doi:10.34045/ssem/2016/17

CrossRef Full Text | Google Scholar

Ljungqvist, A. (2017). Brief History of Anti-Doping. Med. Sport Sci. 62, 1–10. doi:10.1159/000460680

PubMed Abstract | CrossRef Full Text | Google Scholar

Loria, F., Manfredi, M., Reverter-Branchat, G., Segura, J., Kuuranne, T., and Leuenberger, N. (2020). Automation of RNA-based biomarker extraction from dried blood spots for the detection of blood doping. Bioanalysis 12, 729–736. doi:10.4155/bio-2020-0041

PubMed Abstract | CrossRef Full Text | Google Scholar

Mueller, O., Schroeder, A., and Lightfoot, S. (2004). RNA Integrity Number (RIN) - Standardization of RNA Quality Control. Agil. Appl. Note, 1–17.

Google Scholar

Pitsiladis, Y. P., Durussel, J., and Rabin, O. (2014). An integrative 'Omics' solution to the detection of recombinant human erythropoietin and blood doping. Br. J. Sports Med. 48, 856–861. doi:10.1136/bjsports-2014-093529

PubMed Abstract | CrossRef Full Text | Google Scholar

Reichel, C. (2011). OMICS-strategies and methods in the fight against doping. Forensic Sci. Int. 213, 20–34. doi:10.1016/j.forsciint.2011.07.031

PubMed Abstract | CrossRef Full Text | Google Scholar

Reithmeier, R. A. F., Casey, J R., Kalli, A. C., Sansom, M. S. P., Alguel, Y., and Iwata, S. (2016). Band 3, the Human Red Cell Chloride/Bicarbonate Anion Exchanger (AE1, SLC4A1), in a Structural Context. Biochim. Biophys. Acta Biomembr. 1858 (7), 1507–1532.

CrossRef Full Text | Google Scholar

Salamin, O., Gottardo, E., Schobinger, C., Reverter-Branchat, G., Segura, J., Saugy, M., et al. (2019). Detection of Stimulated Erythropoiesis by the RNA-Based 5'-Aminolevulinate Synthase 2 Biomarker in Dried Blood Spot Samples. Clin. Chem. 65, 1563–1571. doi:10.1373/clinchem.2019.306829

PubMed Abstract | CrossRef Full Text | Google Scholar

Saugy, M., Robinson, N., Grimm, K., and Dvorak, J. (2011). Future of the fight against doping: Risk assessment, biological profiling and intelligence testing. Forensic Sci. Int. 213, 1–2. doi:10.1016/j.forsciint.2011.07.008

PubMed Abstract | CrossRef Full Text | Google Scholar

Schmidt, D. R., Patel, R., Kirsch, D. G., Lewis, C. A., Vander Heiden, M. G., and Locasale, J. W. (2021). Metabolomics in cancer research and emerging applications in clinical oncology. Cancer J. Clin., 21670. doi:10.3322/caac.21670

CrossRef Full Text | Google Scholar

Swift, G. H., Peyton, M. J., and MacDonald, R. J. (2000). Assessment of RNA quality by semi-quantitative RT-PCR of multiple regions of a long ubiquitous mRNA. Biotechniques 28, 524–531. doi:10.2144/00283rr01

PubMed Abstract | CrossRef Full Text | Google Scholar

Thevis, M., Kuuranne, T., and Geyer, H. (2021). Annual banned‐substance review: Analytical approaches in human sports drug testing 2019/2020. Drug Test. Anal. 13, 8–35. doi:10.1002/dta.2969

PubMed Abstract | CrossRef Full Text | Google Scholar

WADA (2021a). 2021 World Anti-Doping Code | World Anti-Doping Agency. Available at: https://www.wada-ama.org/en/resources/the-code/2021-world-anti-doping-code (Accessed September 12, 2020).

Google Scholar

WADA (2021b). WADA introduces standard analyzer at all laboratories approved for ABP controls | World Anti-Doping Agency. Available at: https://www.wada-ama.org/en/media/news/2019-06/wada-introduces-standard-analyzer-at-all-laboratories-approved-for-abp-controls (Accessed May 19, 2021).

Google Scholar

WADA (2021c). WADA Releases updated Guidelines to complement the 2021 International Standard for Testing and Investigations | World Anti-Doping Agency. Available at: https://www.wada-ama.org/en/media/news/2021-02/wada-releases-updated-guidelines-to-complement-the-2021-international-standard [Accessed May 19, 2021].

Google Scholar

Wang, G., Durussel, J., Shurlock, J., Mooses, M., Fuku, N., Bruinvels, G., et al. (2017a). Validation of whole-blood transcriptome signature during microdose recombinant human erythropoietin (rHuEpo) administration. BMC Genomics 18. doi:10.1186/s12864-017-4191-7

PubMed Abstract | CrossRef Full Text | Google Scholar

Wang, G., Karanikolou, A., Verdouka, I., Friedmann, T., and Pitsiladis, Y. (2017b). Next Generation “omics” Approaches in the “fight” against Blood Doping. Med. Sport Sci. 62, 119–128. doi:10.1159/000470919

CrossRef Full Text | Google Scholar

XN (2021). XN-1000 - Products Detail. Available at: https://www.sysmex-europe.com/n/products/products-detail/xn-1000.html (Accessed May 19, 2021).

Google Scholar

Keywords: RNA-Seq, frozen blood, RNA integrity, anti-doping, doping biomarkers, gene expression, microarray, Recombinant human erythropoietin

Citation: Lima G, Kolliari-Turner A, Malinsky FR, Guppy FM, Martin RP, Wang G, Voss SC, Georgakopoulos C, Borrione P, Pigozzi F and Pitsiladis Y (2021) Integrating Whole Blood Transcriptomic Collection Procedures Into the Current Anti-Doping Testing System, Including Long-Term Storage and Re-Testing of Anti-Doping Samples. Front. Mol. Biosci. 8:728273. doi: 10.3389/fmolb.2021.728273

Received: 21 June 2021; Accepted: 31 August 2021;
Published: 26 October 2021.

Edited by:

Amelia Palermo, University of California, Los Angeles, United States

Reviewed by:

Carmen Gherasim, University of Michigan, United States
Yang Xie, Brigham and Women’s Hospital and Harvard Medical School, United States

Copyright © 2021 Lima, Kolliari-Turner, Malinsky, Guppy, Martin, Wang, Voss, Georgakopoulos, Borrione, Pigozzi and Pitsiladis. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Yannis Pitsiladis, Y.Pitsiladis@brighton.ac.uk

These authors have contributed equally to this work and share first authorship

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.