Skip to main content

ORIGINAL RESEARCH article

Front. Microbiol., 17 October 2023
Sec. Microbial Symbioses
This article is part of the Research Topic Microbial Ecology Supporting Growth of Free-living Amoebae in Natural and Engineered Water Systems View all 4 articles

Assessing residential activity in a home plumbing system simulator: monitoring the occurrence and relationship of major opportunistic pathogens and phagocytic amoebas

Vicente Gomez-Alvarez
Vicente Gomez-Alvarez1*Hodon RyuHodon Ryu1Min Tang&#x;Min Tang2Morgan McNeelyMorgan McNeely1Christy MuhlenChristy Muhlen1Megan UrbanicMegan Urbanic2Daniel WilliamsDaniel Williams1Darren LytleDarren Lytle1Laura BoczekLaura Boczek1
  • 1Office of Research and Development, U.S. Environmental Protection Agency, Cincinnati, OH, United States
  • 2Oak Ridge for Science and Education Research Fellow at U.S. Environmental Protection Agency, Cincinnati, OH, United States

Opportunistic premise plumbing pathogens (OPPPs) have been detected in buildings’ plumbing systems causing waterborne disease outbreaks in the United States. In this study, we monitored the occurrence of OPPPs along with free-living amoeba (FLA) and investigated the effects of residential activities in a simulated home plumbing system (HPS). Water samples were collected from various locations in the HPS and analyzed for three major OPPPs: Legionella pneumophila, nontuberculous mycobacterial species (e.g., Mycobacterium avium, M. intracellulare, and M. abscessus), and Pseudomonas aeruginosa along with two groups of amoebas (Acanthamoeba and Vermamoeba vermiformis). A metagenomic approach was also used to further characterize the microbial communities. Results show that the microbial community is highly diverse with evidence of spatial and temporal structuring influenced by environmental conditions. L. pneumophila was the most prevalent pathogen (86% of samples), followed by M. intracellulare (66%) and P. aeruginosa (21%). Interestingly, M. avium and M. abscessus were not detected in any samples. The data revealed a relatively low prevalence of Acanthamoeba spp. (4%), while V. vermiformis was widely detected (81%) across all the sampling locations within the HPS. Locations with a high concentration of L. pneumophila and M. intracellulare coincided with the highest detection of V. vermiformis, suggesting the potential growth of both populations within FLA and additional protection in drinking water. After a period of stagnation lasting at least 2-weeks, the concentrations of OPPPs and amoeba immediately increased and then decreased gradually back to the baseline. Furthermore, monitoring the microbial population after drainage of the hot water tank and partial drainage of the entire HPS demonstrated no significant mitigation of the selected OPPPs. This study demonstrates that these organisms can adjust to their environment during such events and may survive in biofilms and/or grow within FLA, protecting them from stressors in the supplied water.

GRAPHICAL ABSTRACT
www.frontiersin.org

Graphical Abstract.

Introduction

The function of a drinking water distribution system is to deliver potable water to all customers of the system in sufficient quantity, at the appropriate pressure, with minimal loss, and with acceptable quality (National Research Council, 2006). Following collection and appropriate treatment, drinking water is supplied to end users via a distribution system that includes service connection lines. Premise plumbing includes that portion of the drinking water distribution system connected via the service line to public and private houses and other buildings (National Research Council, 2006). Water quality within the premise plumbing is not monitored by the United States Environmental Protection Agency (US EPA) regulations, except for the Lead and Copper Rule (LCR). Previously identified problems (including microbial growth) in the drinking water distribution system can also occur in premise plumbing. Studies in homes and occupational buildings have suggested that the water quality within premise plumbing is influenced by a range of factors that are associated with the delivered water quality involving water treatment changes such as a switch from chlorine to chloramine (Pryor et al., 2004), seasonality (Zlatanović et al., 2017), and pressure zone (Haig et al., 2020). In addition, microbial proliferation and growth within plumbing are associated with the deterioration of physico-chemical water quality due to degradation and corrosion of pipe materials (Cullom et al., 2020). As a result, premise plumbing conditions can amplify the potential public health risk relative to the drinking water distribution system. The unique characteristics of premise plumbing (e.g., large surface area to volume ratio, long water age, favorable temperature, and low or no disinfectant residual) provide a favorable environment for microbial proliferation and growth within plumbing surface biofilms, including opportunistic premise plumbing pathogens (OPPPs) that cause infectious disease (National Research Council, 2006). These built environments provide unique conditions for OPPPs exposure via aerosolized water droplets produced by showerheads, faucets, and tubs (Logan-Jackson et al., 2023).

Public health data show a significant fraction of the nation’s waterborne disease outbreaks is attributable to premise plumbing in houses and occupational buildings. Surveillance data in the US indicate an increasing trend in the annual proportion of reported outbreaks associated with premise plumbing deficiencies (Craun et al., 2010; Collier et al., 2021). The most recent drinking water-associated outbreak surveillance data indicates that drinking water exposure was associated with 28% of outbreaks, resulting in 34% of reported cases with nearly 70% of reported hospitalizations, and 93% of deaths (Centers for Disease Control and Prevention, 2022). The 2015 is the latest year a summary report is available due to limited capacity for waterborne disease surveillance and competing response priorities at the Centers for Disease Control and Prevention (CDC). Comprehensive assessments of the health burden of infectious disease in the United States in 2014 estimated 6,630 deaths attributed to waterborne transmission, with most hospitalizations and deaths caused by these opportunistic pathogens, costing $2.39 billion annually (Collier et al., 2021).

Pathogenic bacteria previously recognized as biofilm-associated OPPPs include Legionella pneumophila, nontuberculous mycobacterial (NTM) species, and Pseudomonas aeruginosa (Falkinham et al., 2015). L. pneumophila is the primary causative agent of Legionnaires’ disease (Phin et al., 2014), in which serogroup 1 has been implicated in most cases associated with built environments (Cunha et al., 2016). Despite the implementation of disinfection strategies to mitigate their presence, this Gram-negative bacterium can colonize and persist within building water systems (Berjeaud et al., 2016). Legionnaires’ disease occurs sporadically and in outbreaks, with the sporadic form representing up to 82% of the cases (Sopena et al., 2007). Nevertheless, reported cases of Legionnaires’ disease in the United States have grown nine-fold since 2000 (Centers for Disease Control and Prevention, 2020). NTM species (e.g., Mycobacterium avium, M. intracellulare, and M. abscessus) are increasingly recognized as important opportunistic pathogens of humans (Dahl et al., 2022). In the United States, most pulmonary NTM infections are caused by M. avium-intracellulare complex, with other species, such as M. abscessus complex, also contributing to this disease (Winthrop et al., 2020). Data indicates a global increase in NTM for both Mycobacterium complexes in reports of infection and disease (Dahl et al., 2022). P. aeruginosa is widely occurring in premise plumbing and is recognized for its capacity to form or join biofilms in point-of-use devices, such as faucets, drains, sinks, and showerheads (Bédard et al., 2016). This opportunistic pathogen is an emerging worldwide public health threat and one of the leading causes of nosocomial infections (Moradali et al., 2017).

Previous studies examined the physico-chemical and microbial water quality changes in buildings and their associations (Lautenschlager et al., 2010; Zlatanović et al., 2017; Salehi et al., 2018; Ley et al., 2020; Rhoads et al., 2020). To better understand premise plumbing issues, a home plumbing system (HPS) simulator was constructed in the EPA’s Andrew W. Breidenbach Environmental Research Center (AWBERC) in Cincinnati, Ohio (Lytle et al., 2021). There have already been early studies using the same HPS about the seasonal variation and effect of temperature on OPPPs (Lu et al., 2017a) and the bacterial community diversity (Zhang et al., 2021). However, when residential homes are already contaminated with Legionella (and other OPPPs), no data are available to elucidate how residential activities such as plumbing and heater draining due to residential repair and maintenance would influence the drinking water quality. Therefore, the objective in this study was to characterize the microbial community and examine how populations of OPPPs along with free-living amoeba (FLA) responded to residential activities. Specifically, water samples were collected from various locations in the same HPS during simulated residential plumbing activities (Figure 1) and analyzed for three major OPPPs (L. pneumophila, NTM species [e.g., M. avium, M. intracellulare, and M. abscessus], and P. aeruginosa) and two groups of amoebas (Acanthamoeba and Vermamoeba vermiformis) using quantitative polymerase chain reaction (qPCR). A metagenomic approach was also used to characterize the microbial communities further. We hypothesized that residential activities (i.e., episodes of disturbances) induce a selection pressure on the bacterial community and the OPPP population. The outcome of this study will shed light on the role of residential plumbing activities on water quality and may indicate the mechanisms of these organisms to adjust to their environment during such events, protecting them from stressors in the supplied water.

FIGURE 1
www.frontiersin.org

Figure 1. Model home simulated activities. Timeline of simulated residential activities performed during the study. Red arrows represent sampling events for metagenomics analysis. Orange boxes represent residential activities: stagnation (i.e., 10-day vacation), home repair, and water heater maintenance. Flushing events: baseline (BL); post stagnation (PS); post drain I (PD I); post drain II (PD II).

Materials and methods

Home plumbing system simulator

The Home plumbing system (HPS) simulator was constructed in the EPA’s AWBERC (Cincinnati, Ohio) and has been continuously operated since 2012. Details of the layout and dimensions of the HPS were described previously (Lytle et al., 2021). The simulated HPS includes copper pipes, a 40-gallon electric hot water tank with a recirculating hot water pump, a dishwasher and washing machine, bathroom sinks, a shower, and a toilet (Supplementary Figure S1). The cold water lines and the hot water tank are fed with water that is supplied by the building water supply (Greater Cincinnati Water Works tap water). In May 2021, a new “Random Reduced Normal Use” flushing protocol was started to establish the baseline (BL) water quality for this study. The flush protocol (i.e., daily use by a four-person residence) consisted of opening and running the faucets, shower, and toilet for a combined volume of approximately 70–80 gallons per day. Water temperature and pH were measured with a handheld thermometer (Fisher Scientific, Hampton, NH) and a pH electrode (HACH, Loveland, CO), respectively. Free and total chlorine residuals were measured using the N, N-dimethyl-p-phenylenediamine (DPD) colorimetric method 4,500-CL G (Lipps et al., 2023). Detailed information on the design and flushing protocol for the HPS can be found in Supplementary materials and methods.

Residential activity simulations

Three residential activities were simulated between May–December 2021: (i) extended stagnation (i.e., no use of water during a 10-day vacation), (ii) home plumbing repair, and (iii) water heater maintenance (Figure 1). The first activity simulating a resident’s long vacation was completed by fully stagnating the HPS for 10 days (i.e., no water use). Then the flush protocol (post stagnation: PS) was resumed, and the second activity simulating partial drawdown during home repair and maintenance was conducted by fully draining both hot and cold-water lines but not the water heater for 2 h. Once the partial drawdown was completed, the flush protocol (post drain I: PD I) was resumed. Finally, the third activity, simulating maintenance of the water heater as recommended by the manufacturer (i.e., cleaning), was executed by fully draining the water heater only. After completing the third activity, the flush protocol (post drain II: PD II) was resumed and continued until the end of the study.

Sampling locations and collection

Samples were obtained from nine locations in the HPS: cold-water entry point (EP), hot water tank point of entry and return (WT-T and WT-B, respectively), hot water premise plumbing recirculation (PP), faucets (F1, F2, F3, and F4), and the shower (SH) (Supplementary Figure S1). Sample locations were assigned into three sections: (i) entry point (EP), (ii) water tank and recirculation (WT: WT-T, WT-B, and PP), and (iii) point of use (POU: F1, F2, F3, F4, and SH). Hot water samples (1 liter) were obtained from WT, PP and POU following 63 h of stagnation each week across the simulated residential activities unless stated otherwise, along with EP cold water samples as a comparison. We chose direct water sampling of household plumbing for qPCR instead of biofilm sampling to enhance our sampling effort and co-analyze with physico-chemical water parameters. For metagenomic analysis, bulk water (EP, WT-T, WT-B, and PP) and biofilms (F1–F4) were collected from three flushing events: BL, PS, and PD II (Figure 1). Briefly, 2 L water samples were filtered through a 0.2 μm sterile membrane filter (Pall Corporation, Port Washington, NY) and then cut aseptically to increase surface area for DNA extraction. Biofilms in faucets were harvested by scraping the inner surface of the pipes using sterile swabs.

Quantitative polymerase chain reaction analyses

DNA of each water sample (approximately 850 ml) was immediately extracted via filtration using 0.2 μm sterile membrane (Pall Corporation, Port Washington, NY) according to the manufacturer’s protocol (DNeasy PowerWater kit, Qiagen). DNA concentration was measured using a NanoDrop ND-1000 UV spectrophotometer (NanoDrop Technologies, Wilmington, DE). DNA extracts were stored at −20°C until further processing.

Culture-independent qPCR analyses were conducted for three major OPPP groups: Legionella pneumophila, nontuberculous mycobacterial species (e.g., Mycobacterium avium, M. intracellulare, and M. abscessus), and Pseudomonas aeruginosa and two amoebas (Acanthamoeba and Vermamoeba vermiformis) (Supplementary Table S1). All qPCR assays were performed using a QuantStudio™ 6 Flex system (Applied Biosystems, Foster City, CA) following the procedure described in Ryu et al. (2013). Detailed information on probes, gene targets, and amplification protocols from the purified DNA can be found in Supplementary materials and methods and Supplementary Table S1.

DNA extraction, sequencing, and processing of metagenomic libraries

Total DNA was extracted using the PureFood GMO and Authentication cartridge-based purification kit with the Maxwell® RSC 48 Instrument (Promega, Madison, WI) following the manufacturer’s instructions. Briefly, Filters and swabs were resuspended with 200 μl of CTAB (Promega, Part# MC1411) and 30 μl of Proteinase K (Promega, Part# MC500C), vortexed to mix for 30 s, and incubated at 70°C/5 min in a heat block. Then, 300 μl of Lysis Buffer (Promega, Part# A826D) was added, vortexed to mix for 10 s, and centrifuged. The supernatant was transferred (~1.0 ml) into the top reservoir in the Maxwell cartridge, and 80 μl of elution buffer was added into each collection tube. DNA concentrations were measured using the Quantus™ Fluorometer (Promega, Madison, WI) and stored at −80°C.

Paired-end standard metagenome libraries were prepared using the Illumina HiSeq in the NovaSeq 6,000 S2 PE150 XP sequence mode. Libraries were quality-checked using a 2,100 Bioanalyzer Instrument (Agilent, Santa Clara, USA). Prior to analysis, the 150-nucleotide (nt) pair-end reads were subjected to quality filtering and cleaning from adapters and phiX artifacts, error corrected, normalized (≤100×), and filtered to a minimum length of 100-nt using the bioinformatics software package BBMap v38.221 with the following parameters: ktrim = r, k = 23, mink = 11, hdist = 1, tbo, tpe, maxns = 0, trimq = 10, qtrim = r, maq = 12, minlength = 100, ecco = t, eccc = t, ecct = t, and target = 100. The libraries contained an average ± standard error (±SE) of 29,397,634 ± 6,670,930 reads per sample.

Taxonomic and diversity analysis of metagenomes

Taxonomy was assigned using Kraken2 v2.1.2 (Wood et al., 2019) with a confidence value of 0.1 for a taxonomic assignment using the pre-built custom Genome Taxonomy Database (GTDB) release 2072. Taxonomy counts for each sample were summarized by collapsing taxonomic assignments to the phylum, class, order, family, and genus level with Bracken v.2.8 (Lu et al., 2017b). A Sankey diagram was created using the online tool SankeyMATIC3 to illustrate the taxonomic flow lineages. Diversity indices were calculated based on the rarefied species abundance table across each sample generated by Bracken.

Multivariable ordination and statistical analysis

Principal Coordinated Analysis (PCoA) was used to describe the relationships among microbial communities and was based on the Bray–Curtis similarity matrix. A one-way permutational multivariate analysis of variance (PERMANOVA) test was applied to the distance matrix with 9,999 permutations to determine if there were significant differences (α = 0.05) between the microbial communities (Anderson, 2001). The non-parametric Kendall’s tau correlation was calculated for each pairwise combination of variables (e.g., OPPP abundance, temperature, pH, and free chlorine) in the samples analyzed. A conventional approach was used to interpret the correlation coefficient (Schober et al., 2018) as follows: 0.00–0.09, negligible; 0.10–0.39, weak; 0.40–0.69, moderate, 0.70–0.89, strong; 0.90–1.00, very strong. The significance of the correlation test was set at 95% (p ≤ 0.05). The non-parametric Kruskal-Wallis one-way analysis of variance test for equal medians (α = 0.05) was used to evaluate the differences in diversity indices and water quality parameters between HPS sections and flushing events. Ordination plots and statistical analysis were performed with the software PAST v4.12b (Hammer et al., 2001). The gene copy number (GCN) generated from qPCR assays was transformed into log10 (x + 1) GCN.

Results

Water quality in HPS sections and flushing events after residential activities

A total of 211 water samples were collected from May to December 2021 and analyzed from three sections (entry point: 22 samples, water tank and recirculation: 54, point-of-use: 134) in the HPS. Water temperature, free chlorine residual, and pH were measured to reflect the quality of the entry water (EP) and hot water (WT and POU) sections (Supplementary Figure S1). A flush protocol (i.e., daily use by a four-person residence) was started in the HPS to establish the baseline (BL) water quality and resumed after completing each of the three simulated residential activities (PS, PD I, and PD II). EP samples (i.e., cold water) had an average water temperature of 22.1°C (±0.9 SD), free chlorine residual of 0.86 mg/L (±0.16 SD), and a pH of 7.6 (±0.4 SD) (Supplementary Figure S2). No significant differences were observed between the sample medians of measured water quality parameters in the EP water when using aggregate monthly data (Kruskal–Wallis, Dunn’s test p > 0.05, Supplementary Table S2). Throughout the study, the measured water quality parameters for the EP water remained stable and relatively constant (Figure 2).

FIGURE 2
www.frontiersin.org

Figure 2. Water quality parameters in the HPS. Weekly concentration and measurements of (A) temperature, (B) free chlorine residual, and (C) pH at each section from May to December. Clear and red boxes represent flushing events and simulated residential activities, respectively (see Figure 1). Sections: entry point (EP); water tank and recirculation (WT); point-of-use (POU). Flushing events: baseline (BL); post stagnation (PS); post drain I (PD I); post drain II (PD II). Bars represent ± standard deviation (±SD).

Compared to cold water samples, the Kruskal–Wallis one-way analysis of variance (ANOVA) showed that all physico-chemical parameters within hot water samples were significantly different from the EP water (Supplementary Figure S2). The temperature increased to an average of 31.3°C (±4.3 SD) in the WT section and decreased significantly to 25.5°C (±4.9 SD) in the POU (Kruskal–Wallis, H = 50.6, Dunn’s test p < 0.0001; Supplementary Table S2 and Supplementary Figure S2A). Chlorine residuals were almost entirely depleted in hot water locations and were significantly different from the EP (Kruskal–Wallis, H = 62.1, Dunn’s test p < 0.0001). The average free chlorine value for the WT is 0.11 mg/L (±0.14 SD) and 0.07 mg/L (±0.10 SD) for the POU section (Supplementary Table S2 and Supplementary Figure S2B). The pH in hot water samples increased significantly to 8.6 (±0.5 SD) in WT and 8.2 (±0.5 SD) in POU samples compared to EP samples (Kruskal–Wallis, H = 52.9, Dunn’s test p < 0.0001; Supplementary Table S2 and Supplementary Figure S2C). Chlorine and pH followed similar tendencies across the study, while some variation was observed with temperature in the WT and POU sections (Figure 2).

No significant difference in hot water temperature was observed during flushing events between simulated residential activity in WT (Kruskal–Wallis, H = 1.3, Dunn’s test p > 0.05) and POU (Kruskal–Wallis, H = 7.6, Dunn’s test p > 0.05) sections (Supplementary Figure S3). In contrast, significant differences in the sample medians of free chlorine were observed only after stagnation (i.e., 10-day vacation) and water heater maintenance for both WT and POU (Kruskal–Wallis, Dunn’s test p < 0.001) sections (Supplementary Figure S4). An increase in pH (Kruskal–Wallis, Dunn’s test p < 0.001) was noticed after the water heater maintenance for both hot water sections (Supplementary Figure S5). The home repair residential activity appears to have no effect on the observed physico-chemical parameters.

Microbial communities

Twenty-three metagenome libraries from EP, WT, and POU were generated and analyzed for this study. Bulk water and biofilms were collected from 3 flushing events (BL, PS, and PD II). A total of 4,979 bacterial genera were identified using the Kraken2 package with the database GTDB release 207 (rarefied to 72,300,000 reads per HPS section). Only 1,336 bacterial genera (27% of the total genus diversity) were shared by EP, WT, and POU, representing 99.7–99.9% of the reads in their respective sections. The number of bacterial genera in the EP shared with the hot water sections is <161, while the number of genera shared between the WT and POU hot water sections increased to 1,362. Further analysis revealed that 134 (8% of the bacterial genera and 0.001% of reads), 868 (23 and 0.015%), and 989 (27 and 0.014%) genera were found exclusively in the EP, WT, and POU sections, respectively. Taxonomic classification revealed that most of the diversity was associated with the class Actinomycetia (68.875%), Alphaproteobacteria (17.600%), Vampirovibrionia (5.536%), Gammaproteobacteria (6.269%), Nitrospiria (0.114%), Bacteroidia (0.886%), Bacilli (0.105%), Polyangia (0.016%), Planctomycetia (0.078%), Gemmatimonadetes (0.400%), Verrucomicrobiae (0.009%), Phycisphaerae (0.015%), Acidimicrobiia (0.002%), Deinococci (0.018%), and Anaerolineae (0.003%) with additional representatives of 214 classes detected to a lesser extent (≤0.01% each) (Figure 3A).

FIGURE 3
www.frontiersin.org

Figure 3. Comparison of EP, WT, and POU bacterial communities across flushing events. (A) Sankey diagram of the taxonomic distribution of bacteria at the class level. Classes are ordered from top to bottom by the most abundant in the total community. Others represent 214 additional classes with a relative distribution of <0.01%. The two columns from left to right represent the taxonomic groups scaled by the number of taxonomic representatives and flushing event for their respective sections. (B) PCoA of metagenomes based on Bray–Curtis similarity at the genus level. Sections: entry point (EP); water tank and recirculation (WT); point-of-use (POU). Flushing events: baseline (BL); post stagnation (PS); post drain II (PD II).

Metagenomic-based alpha diversity indexes and rarefaction analysis revealed this system’s diversity of bacterial groups. Observed bacteria genera (Supplementary Figure S6A) and diversity metrics (Supplementary Figures S6B,C) were higher in hot water sections (WT and POU) compared to the EP communities. In hot water sections, observed indices in WT slightly decreased compared to POU but did not reach statistical significance (Kruskal–Wallis, Dunn’s test p > 0.05). Principal coordinated analysis (PCoA) analysis formed three defined clusters (PERMANOVA: F = 4.19, p = 0.0014; Figure 3B). The community composition (i.e., distribution) shifted markedly between HPS sections: the dominant class switched with an increase in the temperature from Actinomycetia (>95%) in EP communities to Alphaproteobacteria, Gammaproteobacteria, Vampirovibrionia, Nitrospiria, Bacteroidia, and Gemmatimonadetes in hot water sections. The POU communities (i.e., biofilms) were differentiated from the WT by an increase in the proportion of Alphaproteobacteria (from 11 to 41%) and Bacteroidia (0.4 to 2%), and a decrease in the proportion of Actinomycetia (62 to 48%), Gammaproteobacteria (15 to 4%), Vampirovibrionia (11 to 5%), and Gemmatimonadetes (1.1 to 0.1%). This dissimilarity is explained by a small number of genus-level taxa (29 out of 2,977 representing <1% of the genus) whose relative abundance varied significantly among the HPS sections (PERMANOVA: F = 4.19, p = 0.0014; rarefied to 249,000 reads per HPS sample). The 29 taxa are among the most abundant taxa (representing >94% of the total distribution of reads) and explains 90% of the dissimilarity within HPS sections. The Mycobacterium genus represents 62% of the total diversity. The dominant taxa (in the following distribution order) in EP communities were closely related to members of the genus Mycobacterium and QKMZ01 (class Vampirovibrionia). Representatives of the genus Mycobacterium, QKMZ01, UBA4763 (class Alphaproteobacteria), Sphingomonas, Nitrospira_F, and Methyloversatilis were overrepresented in the WT section. The POU section was dominated by the genus Mycobacterium, Bradyrhizobium, Sphingomonas, QKMZ01, Reyranella, Afipia, and Sphingopyxis.

Cell density of OPPPs and FLA in drinking water samples

A total of 211 bulk water samples were analyzed for the presence of OPPPs along with two FLA (Supplementary Table S1). Across all assays, L. pneumophila was the most prevalent pathogen (86% of samples), followed by M. intracellulare (66%) and P. aeruginosa (21%). Interestingly, M. avium and M. abscessus were not detected in any samples. The data revealed a relatively low prevalence of Acanthamoeba spp. (4%), while V. vermiformis was widely detected (81%) across all the sampling locations within the HPS.

As summarized in Supplementary Table S2 and Supplementary Figure S7, L. pneumophila, and V. vermiformis had the highest level of cell density among the selected targets. The gene copy number (GCN) per mL was converted to log10(x + 1). The average of the estimated L. pneumophila gene copy number (±SD) is 1.4 ± 0.3, 2.7 ± 0.8, and 2.5 ± 1.0 copies for EP, WT, and POU, respectively. The L. pneumophila quantities in EP were significantly lower (Kruskal–Wallis, H = 38.1, Dunn’s test p < 0.0001) than those in WT and POU sections. Similarly, the V. vermiformis density in the EP section (0.8 ± 0.4 copies) was an order of magnitude lower than those in the hot water sections (ranged from 1.8 ± 0.9 to 2.5 ± 1.2 copies). Furthermore, significant differences in cell density were found between the hot water sections for L. pneumophila and V. vermiformis. In contrast, M. intracellulare quantities decreased significantly in hot water sections from 0.8 ± 0.3 to 0.4 ± 0.3 copies (Kruskal–Wallis, H = 18.6, Dunn’s test p < 0.001). For M. intracellulare, no significant differences in cell density were detected in both hot water sections. No significant difference was observed for P. aeruginosa copies (ranged from 0.2 ± 0.1 to 0.3 ± 0.2) among all sections (Kruskal-Wallis, H = 0.6, Dunn’s test p > 0.05).

Variation in GCN (i.e., cell density) was noticed between flushing events at each hot water section (Supplementary Figure S8). The Kruskal-Wallis one-way ANOVA test determined that changes in cell density for M. intracellulare, P. aeruginosa, and V. vermiformis were not different within flushing events (Supplementary Table S3). In contrast, cell density for L. pneumophila changed significantly between some of the flushing events in WT (Kruskal–Wallis, H = 8.6, Dunn’s test p < 0.0001) and POU (Kruskal–Wallis, H = 22.2, Dunn’s test p < 0.001) sections. Furthermore, no immediate effect was observed from the simulated residential flushing activity on cell density for most of the targeted species (Supplementary Figure S9). In most cases, the cell density remained consistent or recovered immediately to previous levels within a short time (Figure 4). As observed previously with the physico-chemical parameters, the cell density of selected species in both hot water sections followed similar patterns over time (Figure 4).

FIGURE 4
www.frontiersin.org

Figure 4. Cell density by qPCR of selected OPPPs and FLA in drinking water samples. Average gene copy number (log10[x + 1]/mL) detected for L. pneumophila (A), M. intracellulare (B), P. aeruginosa (C), and V. vermiformis (D) at each section and flushing event. Clear and red boxes represent flushing events and simulated residential activities, respectively (see Figure 1). Sections: entry point (EP); water tank and recirculation (WT); point-of-use (POU). Flushing events: baseline (BL); post stagnation (PS); post drain I (PD I); post drain II (PD II). Bars represent ± SD. GCN, gene copy number.

Correlation between targeted species and environmental parameters

The non-parametric Kendall’s tau (τ) correlation test showed an association between environmental parameters (temperature, chlorine, and pH) and targeted species (Figure 5). The species L. pneumophila (τ = −0.36, p < 0.0001, Figure 5A), M. intracellulare (τ = −0.20, p < 0.01, Figure 5B), and V. vermiformis (τ = −0.38, p < 0.0001, Figure 5C) were negatively correlated with an observed increase in chlorine residual. In addition, L. pneumophila (τ = −0.16, p < 0.01) and V. vermiformis (τ = −0.27, p < 0.0001) were negatively associated with an observed increase in temperature. The occurrence of L. pneumophila (τ = 0.45, p < 0.0001) and M. intracellulare (τ = 0.35, p < 0.0001) were significantly higher in samples where there was a substantial concentration of V. vermiformis (Figures 5D,E). The correlation analysis revealed a range of weak to moderate associations between environmental parameters and the occurrence of FLA in water samples.

FIGURE 5
www.frontiersin.org

Figure 5. Correlation of OPPP taxa and water quality variables. Heatmap showing the Kendall’s Tau (τ) correlation coefficients and statistical significance between OPPP abundance and water physico-chemical parameters. Significant correlations marked by gray squares (p < 0.05) with positive and negative correlations displayed in blue and red circles, respectively. Size and color intensity is proportional to the correlation coefficients, as shown on the scale below the matrix. Kendall’s Tau negative correlations between disinfectant residual and (A) L. pneumophila, (B) M. intracellulare, and (C) V. vermiformis, and positive correlations between V. vermiformis and (D) L. pneumophila and (E) M. intracellulare.

Discussion

The microbial community composition of the HPS simulator shows a highly diverse bacterial community with evidence of spatial and temporal structuring influenced by the environmental conditions (cold water entry point vs. hot water and bulk water vs. biofilm). Early studies using 16S-rRNA-gene-based high-throughput DNA sequencing of the same HPS indicated that the bacterial community structure of a hot water faucet was significantly different from those of a cold water faucet (Zhang et al., 2021). As noted above, the effect of water heater temperature is evident and have a substantial impact on the microbial communities (Meyer et al., 2023). This dissimilarity is explained by the 29 bacterial genera (out of 4,979) representing >94% of the total read distribution. The rest of the taxa represent the rare biosphere and can explain <10% of the dissimilarity within the HPS microbial community. This suggests minor contributions to the dissimilarities found within the community. Nevertheless, we must recognize the importance of this fraction and the possible implications for their contribution to the overall function of this diverse microbial ecosystem. Furthermore, additional investigations of the rare biosphere (including opportunistic pathogens that can cause infectious disease) suggest that these communities have the potential to seed other biofilm communities, which can increase under favorable conditions (Gomez-Alvarez et al., 2016).

The unique characteristics of premise plumbing can provide a favorable environment for the microbial proliferation of OPPPs and the establishment of biofilms within the premise plumbing (National Research Council, 2006). As a result, premise plumbing infrastructures can amplify the potential public health risk within the drinking water distribution system. The HPS is dominated by the class Actinomycetia with a high proportion consisting of the genus Mycobacterium and representatives of the species M. phocaicum, M. gordonae, M. gadium, M. tusciae, M. paragordonae, M. mucogenicum, and M. chelonae. The dominance of this class and their respective genus were not altered after changes in the flushing event (circa 2021). Community composition of samples obtained in 2012–2013 indicated the relative higher abundance of the family Mycobacteriaceae (approximately 30%) in cold and hot water samples (Zhang et al., 2021). It appears that environmental disturbances, as with any water management changes (i.e., flushing event), does not influence the prevalence and abundance of NTM in the HPS. This group of nontuberculous mycobacteria (NTM) are ubiquitous in the environment (Covert et al., 1999) and have been frequently found in residential premise plumbing (Dowdell et al., 2019). NTM has emerged as a significant cause of opportunistic infections causing pulmonary disease with their incidence, and the number of deaths associated with these infections have been steadily increasing globally (Ratnatunga et al., 2020). For specific populations of OPPPs, our analysis confirmed the widespread prevalence of L. pneumophila in 86% of bulk water samples, followed by M. intracellulare at 66% and P. aeruginosa at 21%. Interestingly, M. avium and M. abscessus were undetected in any samples. Similar results were obtained on samples collected in 2012–2013 by Lu et al. (2017a) with an overall occurrence of Mycobacterium spp. of 100%, followed by Vermamoeba vermiformis with 91%, Legionella spp. with 59%, P. aeruginosa with 14%, and Acanthamoeba spp. with 5%. These results clearly identify the HPS as a consistent reservoir for OPPPs (Hayward et al., 2022).

The microbial proliferation and growth within premise plumbing are directly associated with the complexity of the infrastructure, along with the various physico-chemical water quality parameters. For example, Ling et al. (2018) showed that small-diameter pipes widely used in residential homes harbored the highest cell density compared to the city-water supply microbiome. Water quality parameters such as chlorine concentration, pH (Ji et al., 2015), and water heater temperature (Ji et al., 2017) exhibited the strongest determinants of the microbial composition of the building plumbing microbiome. Early studies indicated significant variations in the density of OPPPs and water temperatures, especially for Mycobacterium spp., Legionella spp. and V. vermiformis (Lu et al., 2017a). This was observed in our HPS, where selected OPPPs and FLA were detected in higher abundances in the residential hot water sections than in entry point samples. The hot water sections were characterized by a lower chlorine residual, large surface area, and an increase in water temperature and pH. The only exception was M. intracellulare, with a greater increase in gene count observed at the entry point, but further qPCR analysis using mycobacterial marker genes (ITS and 23S rRNA) indicated a higher overall cell density of the genus Mycobacterium within all the residential sections (data not shown). On average, L. pneumophila and V. vermiformis showed an increase in one or more orders of magnitude. Among the hot water section, point-of-use (POU) devices showed a higher gene count for L. pneumophila and V. vermiformis. POU, such as the shower and faucets, are important locations for biofilm formation and bacterial regrowth (Hemdan et al., 2021; Hayward et al., 2022). Establishing within a multispecies biofilm is a strategy by L. pneumophila to overcome the nutrient limitation found in the environment (Declerck, 2010; Abu Khweek and Amer, 2018). In this case, adhering to a pre-established biofilm by other bacteria (e.g., NTM) assists in the survival and growth of L. pneumophila in the HPS. This is demonstrated by the results of the metagenome-based analysis indicating the presence and relatively high abundance of NTM in POU biofilm.

An interesting topic of discussion and research for ensuring public health in plumbing systems is the relationship between bacteria and FLA. Previous studies demonstrated that many bacteria, including OPPPs, benefit from interactions with FLA (Sun et al., 2018). The cyst stage of FLA is a survival mechanism that is resistant to various stresses and provides a protective niche for pathogenic bacteria against adverse conditions (Lambrecht et al., 2015). Indeed, our study indicated that the species L. pneumophila and M. intracellulare were positively correlated with an increase in the abundance of V. vermiformis. Previous studies have noted a positive association between the relative abundances of pathogenic bacteria and V. vermiformis (Siddiqui et al., 2021). Mycobacterium spp. and V. vermiformis not only co-occurred with Legionella spp. but also trended to increase with increasing temperatures (Lu et al., 2017a). Protozoa serves as habitats that provide the environmental host for the survival and replication of OPPP species in drinking water environmental settings (Malinowski et al., 2022; Nisar et al., 2022). Furthermore, our study suggested that these interactions are determined by the location or type of environment in the HPS. Our observation shows that the relationship between L. pneumophila and V. vermiformis increased significantly in POU devices (τ = 0.60) compared to the WT section (τ = 0.45). Comparable results were observed for Mycobacterium spp. (WT τ = 0.32 vs. POU τ = 0.42). POU devices such as the shower and faucets are important locations for biofilm formation and bacterial regrowth. These locations are characterized by small-diameter pipes, and high surface area that is considered the preferred niche for the interactions of bacteria and potential amoeba hosts. Interestingly, M. intracellulare maintains a similar association in both sections. This may suggest that the association between M. intracellulare and FLA is not influenced by the location in the HPS. Conversely, the L. pneumophila gene copy number was positively associated with those of M. intracellulare. Similar observations from a drinking water distribution system have been reported in the literature (Lu et al., 2016). Therefore, their association, particularly in HPS, may be more important than previously considered. Overall, the relationship between OPPPs and FLA and their locations in the plumbing system is of increasing concern for facility managers and residential occupants as they cause human diseases. Favorable conditions (e.g., residual disinfectant, water temperature, stagnation) found at these POU locations promoted the establishment and further interaction of OPPPs and FLA. Consequently, drinking water taps (i.e., POU) may be an important source of human exposure to aerosols containing OPPPs in residential and building structures (Hayward et al., 2022).

The growth of bacterial pathogens in premise plumbing may be unavoidable; however, understanding the effect of residential activities and the potential response by OPPP populations is important for ensuring public health. There is a common notion that episodes of disturbances (e.g., residential activities) induce a selection pressure on microbial populations (Allison and Martiny, 2008); however, our data provides evidence that residential activities do not produce long-term effects on cell density and microbial community structure. This study demonstrated that targeted OPPP and FLA populations, although sensitive to changes due to operational parameters (i.e., stagnation, drain), responded to a disturbance by returning to their stable state after a brief shift in cell abundance (i.e., resilience). After stagnation (at least 2 weeks), OPPP and amoeba densities immediately increased and gradually decreased to the baseline. This suggests maintaining disinfectant residuals is essential for ensuring low microbial numbers and diversity. Furthermore, monitoring the microbial population after drainage of the hot water tank and partial drainage of the entire HPS demonstrated no significant mitigation of the selected OPPPs. This study demonstrates that these organisms can adjust to their environment during such events and may survive in biofilms and/or grow within FLA, protecting them from stressors in the supplied water.

Conclusion

The microbial communities in the HPS sections exhibited a distribution pattern of few dominant taxa and a significant representation of low-abundance species.

Metagenomes-based analysis confirmed that premise plumbing (i.e., hot water sites) harbors higher microbial richness and composition compared to communities analyzed from the point-of-entry (i.e., water main). The observed changes in the community structure corresponded to reduction of chlorine residual and changes in water temperature, suggesting that these conditions should induce changes on the microbial community.

Community composition associated with deterioration of physico-chemical water quality was not only evident at the community structure level, but also evident at the population level (e.g., OPPPs).

The effect of residential activity combined with the resilience of a diverse group of opportunistic pathogens may constitute a significant challenge for the efficiency of drinking water management plans and affect drinking water safety.

Comparative analysis of the community suggested the relevance of co-occurrence relationships in the drinking water microbial composition of HPS. The presence and occurrence of FLA may have significant implications for the survival of OPPPs in residential systems.

Data availability statement

The datasets presented in this study can be found in online repositories. The names of the repository/repositories and accession number(s) can be found in the NCBI Sequence Read Archive (SRA) under the BioProject PRJNA961987 with the following BioSample numbers: SAMN34376234, SAMN34376235, SAMN34376236, SAMN34376237, SAMN34376238, SAMN34376239, SAMN34376240, SAMN34376241, SAMN34376242, SAMN34376243, SAMN34376244, SAMN34376245, SAMN34376246, SAMN34376247, SAMN34376248, SAMN34376249, SAMN34376250, SAMN34376251, SAMN34376252, SAMN34376253, SAMN34376254, SAMN34376255, and SAMN34376256.

Author contributions

VG-A: Investigation, Formal Analysis, Visualization, Writing – original draft, Writing – review & editing. HR: Conceptualization, Investigation, Formal Analysis, Data curation, Writing – original draft, Writing – review & editing. MT: Investigation, Writing – review & editing. MM: Investigation, Writing – review & editing. CM: Investigation, Writing – review & editing. MU: Investigation, Writing – review & editing. DW: Investigation, Writing – review & editing. DL: Conceptualization, Investigation, Writing – review & editing. LB: Conceptualization, Investigation, Formal Analysis, Data curation, Writing – original draft, Writing – review & editing.

Funding

The author(s) declare financial support was received for the research, authorship, and/or publication of this article. This research was supported by EPA Office of Research and Development’s Safe and Sustainable Water Resources Program (SSWR.7). This work was also supported in part by an appointment to the Internship/Research Participation Program at the Office of Research and Development, U.S. EPA, administered by the Oak Ridge Institute for Science and Education through an interagency agreement between the U.S. Department of Energy and EPA.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

The author(s) declared that they were an editorial board member of Frontiers, at the time of submission. This had no impact on the peer review process and the final decision.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Author disclaimer

This document has been reviewed in accordance with U.S. Environmental Protection Agency (EPA) policy and approved for publication. Any mention of trade names, manufacturers or products does not imply an endorsement by the United States Government or the EPA. EPA and its employees do not endorse any commercial products, services, or enterprises.

Supplementary material

The Supplementary material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fmicb.2023.1260460/full#supplementary-material

Abbreviations

BL, Baseline (flush protocol); EP, Entry point; F, Faucet; FLA, Free-living amoeba; HPS, Home plumbing system; LCR, Lead and copper rule; NTM, Nontuberculous mycobacterial; OPPP, Opportunistic premise plumbing pathogens; PD, Post drain (flush protocol); POU, Point of use; PS, Post stagnation (flush protocol); SH, Shower head; WT, Water tank.

Footnotes

References

Abu Khweek, A., and Amer, A. O. (2018). Factors mediating environmental biofilm formation by Legionella pneumophila. Front. Cell. Infect. Microbiol. 8:38. doi: 10.3389/fcimb.2018.00038

PubMed Abstract | CrossRef Full Text | Google Scholar

Allison, S. D., and Martiny, J. B. (2008). Colloquium paper: resistance, resilience, and redundancy in microbial communities. Proc. Natl. Acad. Sci. U. S. A. 105, 11512–11519. doi: 10.1073/pnas.0801925105

PubMed Abstract | CrossRef Full Text | Google Scholar

Anderson, M. J. (2001). A new method for non-parametric multivariate analysis of variance. Austral Ecol. 26, 32–46. doi: 10.1111/j.1442-9993.2001.01070.pp.x

CrossRef Full Text | Google Scholar

Bédard, E., Prévost, M., and Déziel, E. (2016). Pseudomonas aeruginosa in premise plumbing of large buildings. Microbiology 5, 937–956. doi: 10.1002/mbo3.391

PubMed Abstract | CrossRef Full Text | Google Scholar

Berjeaud, J. M., Chevalier, S., Schlusselhuber, M., Portier, E., Loiseau, C., Aucher, W., et al. (2016). Legionella pneumophila: the paradox of a highly sensitive opportunistic waterborne pathogen able to persist in the environment. Front. Microbiol. 7:486. doi: 10.3389/fmicb.2016.00486

PubMed Abstract | CrossRef Full Text | Google Scholar

Centers for Disease Control and Prevention . (2020). Legionnaires’ disease surveillance summary report, United States, 2018–2019. Atlanta, GA: Centers for Disease Control and Prevention

Google Scholar

Centers for Disease Control and Prevention . Waterborne disease and outbreak surveillance system (WBDOSS) summary report, United States, 2015. Atlanta, GA: U.S. Department of Health and Human Services, CDC (2022).

Google Scholar

Collier, S. A., Deng, L., Adam, E. A., Benedict, K. M., Beshearse, E. M., Blackstock, A. J., et al. (2021). Estimate of burden and direct healthcare cost of infectious waterborne disease in the United States. Emerg. Infect. Dis. 27, 140–149. doi: 10.3201/eid2701.190676

PubMed Abstract | CrossRef Full Text | Google Scholar

Covert, T. C., Rodgers, M. R., Reyes, A. L., and Stelma, G. N. Jr. (1999). Occurrence of nontuberculous mycobacteria in environmental samples. Appl. Environ. Microbiol. 65, 2492–2496. doi: 10.1128/AEM.65.6.2492-2496.1999

CrossRef Full Text | Google Scholar

Craun, G. F., Brunkard, J. M., Yoder, J. S., Roberts, V. A., Carpenter, J., Wade, T., et al. (2010). Causes of outbreaks associated with drinking water in the United States from 1971 to 2006. Clin. Microbiol. Rev. 23, 507–528. doi: 10.1128/CMR.00077-09

PubMed Abstract | CrossRef Full Text | Google Scholar

Cullom, A. C., Martin, R. L., Song, Y., Williams, K., Williams, A., Pruden, A., et al. (2020). Critical review: propensity of premise plumbing pipe materials to enhance or diminish growth of Legionella and other opportunistic pathogens. Pathogens 9:957. doi: 10.3390/pathogens9110957

PubMed Abstract | CrossRef Full Text | Google Scholar

Cunha, B. A., Burillo, A., and Bouza, E. (2016). Legionnaires' disease. Lancet 387, 376–385. doi: 10.1016/S0140-6736(15)60078-2

CrossRef Full Text | Google Scholar

Dahl, V. N., Mølhave, M., Fløe, A., van Ingen, J., Schön, T., Lillebaek, T., et al. (2022). Global trends of pulmonary infections with nontuberculous mycobacteria: a systematic review. Int. J. Infect. Dis. 125, 120–131. doi: 10.1016/j.ijid.2022.10.013

PubMed Abstract | CrossRef Full Text | Google Scholar

Declerck, P. (2010). Biofilms: the environmental playground of Legionella pneumophila. Environ. Microbiol. 12, 557–566. doi: 10.1111/j.1462-2920.2009.02025.x

CrossRef Full Text | Google Scholar

Dowdell, K., Haig, S. J., Caverly, L. J., Shen, Y., LiPuma, J. J., and Raskin, L. (2019). Nontuberculous mycobacteria in drinking water systems - the challenges of characterization and risk mitigation. Curr. Opin. Biotechnol. 57, 127–136. doi: 10.1016/j.copbio.2019.03.010

PubMed Abstract | CrossRef Full Text | Google Scholar

Falkinham, J. O., Pruden, A., and Edwards, M. (2015). Opportunistic premise plumbing pathogens: increasingly important pathogens in drinking water. Pathogens. 4, 373–386. doi: 10.3390/pathogens4020373

PubMed Abstract | CrossRef Full Text | Google Scholar

Gomez-Alvarez, V., Pfaller, S., Pressman, J. G., Wahman, D. G., and Revetta, R. P. (2016). Resilience of microbial communities in a simulated drinking water distribution system subjected to disturbances: role of conditionally rare taxa and potential implications for antibiotic-resistant bacteria. Environ. Sci.: Water Res. Technol. 2, 645–657. doi: 10.1039/C6EW00053C

CrossRef Full Text | Google Scholar

Haig, S. J., Kotlarz, N., Kalikin, L. M., Chen, T., Guikema, S., LiPuma, J. J., et al. (2020). Emerging investigator series: bacterial opportunistic pathogen gene markers in municipal drinking water are associated with distribution system and household plumbing characteristics. Environ. Sci. Water Res. Technol. 6, 3032–3043. doi: 10.1039/d0ew00723d

CrossRef Full Text | Google Scholar

Hammer, Ø., Harper, D. A. T., and Ryan, P. D. (2001). PAST: paleontological statistics software package for education and data analysis. Palaeontol. Electron. 4, 1–9.

Google Scholar

Hayward, C., Ross, K. E., Brown, M. H., Bentham, R., and Whiley, H. (2022). The presence of opportunistic premise plumbing pathogens in residential buildings: a literature review. Water 14:1129. doi: 10.3390/w14071129

CrossRef Full Text | Google Scholar

Hemdan, B. A., El-Taweel, G. E., Goswami, P., Pant, D., and Sevda, S. (2021). The role of biofilm in the development and dissemination of ubiquitous pathogens in drinking water distribution systems: an overview of surveillance, outbreaks, and prevention. World J. Microbiol. Biotechnol. 37:36. doi: 10.1007/s11274-021-03008-3

PubMed Abstract | CrossRef Full Text | Google Scholar

Ji, P., Parks, J., Edwards, M. A., and Pruden, A. (2015). Impact of water chemistry, pipe material and stagnation on the building plumbing microbiome. PLoS One 10:e0141087. doi: 10.1371/journal.pone.0141087

PubMed Abstract | CrossRef Full Text | Google Scholar

Ji, P., Rhoads, W. J., Edwards, M. A., and Pruden, A. (2017). Impact of water heater temperature setting and water use frequency on the building plumbing microbiome. ISME J. 11, 1318–1330. doi: 10.1038/ismej.2017.14

PubMed Abstract | CrossRef Full Text | Google Scholar

Lambrecht, E., Baré, J., Chavatte, N., Bert, W., Sabbe, K., and Houf, K. (2015). Protozoan cysts act as a survival niche and protective shelter for foodborne pathogenic bacteria. Appl. Environ. Microbiol. 81, 5604–5612. doi: 10.1128/AEM.01031-15

PubMed Abstract | CrossRef Full Text | Google Scholar

Lautenschlager, K., Boon, N., Wang, Y., Egli, T., and Hammes, F. (2010). Overnight stagnation of drinking water in household taps induces microbial growth and changes in community composition. Water Res. 44, 4868–4877. doi: 10.1016/j.watres.2010.07.032

PubMed Abstract | CrossRef Full Text | Google Scholar

Ley, C. J., Proctor, C. R., Singh, G., Ra, K., Noh, Y., Odimayomi, T., et al. (2020). Drinking water microbiology in a water-efficient building: stagnation, seasonality, and physicochemical effects on opportunistic pathogen and total bacteria proliferation. Environ. Sci.: Water Res. Technol. 6, 2902–2913. doi: 10.1039/d0ew00334d

CrossRef Full Text | Google Scholar

Ling, F., Whitaker, R., LeChevallier, M. W., and Liu, W. T. (2018). Drinking water microbiome assembly induced by water stagnation. ISME J. 12, 1520–1531. doi: 10.1038/s41396-018-0101-5

PubMed Abstract | CrossRef Full Text | Google Scholar

Lipps, W.C., Braun-Howland, E.B., and Baxter, T.E. (2023). Standard methods for the examination of water and wastewater, 24th. Washington DC: APHA Press.

Google Scholar

Logan-Jackson, A. R., Batista, M. D., Healy, W., Ullah, T., Whelton, A. J., Bartrand, T. A., et al. (2023). A critical review on the factors that influence opportunistic premise plumbing pathogens: from building entry to fixtures in residences. Environ. Sci. Technol. 57, 6360–6372. doi: 10.1021/acs.est.2c04277

PubMed Abstract | CrossRef Full Text | Google Scholar

Lu, J., Breitwieser, F. P., Thielen, P., and Salzberg, S. L. (2017b). Bracken: estimating species abundance in metagenomics data. PeerJ Comput. Sci. 3:e104. doi: 10.7717/peerj-cs.104

CrossRef Full Text | Google Scholar

Lu, J., Buse, H., Struewing, I., Zhao, A., Lytle, D., and Ashbolt, N. (2017a). Annual variations and effects of temperature on Legionella spp. and other potential opportunistic pathogens in a bathroom. Environ. Sci. Pollut. Res. Int. 24, 2326–2336. doi: 10.1007/s11356-016-7921-5

CrossRef Full Text | Google Scholar

Lu, J., Struewing, I., Vereen, E., Kirby, A. E., Levy, K., Moe, C., et al. (2016). Molecular detection of Legionella spp. and their associations with Mycobacterium spp., Pseudomonas aeruginosa and amoeba hosts in a drinking water distribution system. J. Appl. Microbiol. 120, 509–521. doi: 10.1111/jam.12996

PubMed Abstract | CrossRef Full Text | Google Scholar

Lytle, D. A., Formal, C., Cahalan, K., Muhlen, C., and Triantafyllidou, S. (2021). The impact of sampling approach and daily water usage on lead levels measured at the tap. Water Res. 197:117071. doi: 10.1016/j.watres.2021.117071

PubMed Abstract | CrossRef Full Text | Google Scholar

Malinowski, N., Domingos, S., Wylie, J., Morgan, M. J., Metcalfe, S., Walsh, T., et al. (2022). Free-living amoeba and associated pathogenic bacteria in well-chlorinated drinking water storage tanks. ACS ES&T Water 2, 1511–1520. doi: 10.1021/acsestwater.1c00428

CrossRef Full Text | Google Scholar

Meyer, B., Pannekens, M., Soares, A. R., Timmermann, L., Probst, A. J., Hippelein, M., et al. (2023). Bacterial populations in different parts of domestic drinking water systems are distinct and adapted to the given ambient temperatures. Front. Water. 5:2023. doi: 10.3389/frwa.2023.1119951

CrossRef Full Text | Google Scholar

Moradali, M. F., Ghods, S., and Rehm, B. H. (2017). Pseudomonas aeruginosa lifestyle: a paradigm for adaptation, survival, and persistence. Front. Cell. Infect. Microbiol. 7:39. doi: 10.3389/fcimb.2017.00039

PubMed Abstract | CrossRef Full Text | Google Scholar

National Research Council . (2006). Drinking water distribution systems: Assessing and reducing risks. Washington, D.C.: The National Academies Press

Google Scholar

Nisar, M. A., Ross, K. E., Brown, M. H., Bentham, R., Hinds, J., and Whiley, H. (2022). Molecular screening and characterization of Legionella pneumophila associated free-living amoebae in domestic and hospital water systems. Water Res. 226:119238. doi: 10.1016/j.watres.2022.119238

CrossRef Full Text | Google Scholar

Phin, N., Parry-Ford, F., Harrison, T., Stagg, H. R., Zhang, N., Kumar, K., et al. (2014). Epidemiology and clinical management of Legionnaires' disease. Lancet Infect. Dis. 14, 1011–1021. doi: 10.1016/S1473-3099(14)70713-3

CrossRef Full Text | Google Scholar

Pryor, M., Springthorpe, S., Riffard, S., Brooks, T., Huo, Y., Davis, G., et al. (2004). Investigation of opportunistic pathogens in municipal drinking water under different supply and treatment regimes. Water Sci. Technol. 50, 83–90. doi: 10.2166/wst.2004.0025

CrossRef Full Text | Google Scholar

Ratnatunga, C. N., Lutzky, V. P., Kupz, A., Doolan, D. L., Reid, D. W., Field, M., et al. (2020). The rise of non-tuberculosis mycobacterial lung disease. Front. Immunol. 11:303. doi: 10.3389/fimmu.2020.00303

PubMed Abstract | CrossRef Full Text | Google Scholar

Rhoads, W. J., Bradley, T. N., Mantha, A., Buttling, L., Keane, T., Pruden, A., et al. (2020). Residential water heater cleaning and occurrence of Legionella in Flint, MI. Water Res. 171:115439. doi: 10.1016/j.watres.2019.115439

PubMed Abstract | CrossRef Full Text | Google Scholar

Ryu, H., Henson, M., Elk, M., Toledo-Hernandez, C., Griffith, J., Blackwood, D., et al. (2013). Development of quantitative PCR assays targeting 16S rRNA gene of Enterococcus spp. and their application to the identification of Enterococcus species in environmental samples. Appl. Environ. Microbiol. 79, 196–204. doi: 10.1128/AEM.02802-12

PubMed Abstract | CrossRef Full Text | Google Scholar

Salehi, M., Abouali, M., Wang, M., Zhou, Z., Nejadhashemi, A. P., Mitchell, J., et al. (2018). Case study: fixture water use and drinking water quality in a new residential green building. Chemosphere 195, 80–89. doi: 10.1016/j.chemosphere.2017.11.070

PubMed Abstract | CrossRef Full Text | Google Scholar

Schober, P., Boer, C., and Schwarte, L. A. (2018). Correlation coefficients: appropriate use and interpretation. Anesth. Analg. 126, 1763–1768. doi: 10.1213/ANE.0000000000002864

CrossRef Full Text | Google Scholar

Siddiqui, R., Makhlouf, Z., and Khan, N. A. (2021). The increasing importance of Vermamoeba vermiformis. J. Eukaryot. Microbiol. 68:e12857. doi: 10.1111/jeu.12857

CrossRef Full Text | Google Scholar

Sopena, N., Force, L., Pedro-Botet, M. L., Barrufet, P., Sauca, G., García-Núñez, M., et al. (2007). Sporadic and epidemic community legionellosis: two faces of the same illness. Eur. Respir. J. 29, 138–142. doi: 10.1183/09031936.00077206

CrossRef Full Text | Google Scholar

Sun, S., Noorian, P., and McDougald, D. (2018). Dual role of mechanisms involved in resistance to predation by protozoa and virulence to humans. Front. Microbiol. 9:1017. doi: 10.3389/fmicb.2018.01017

PubMed Abstract | CrossRef Full Text | Google Scholar

Winthrop, K. L., Marras, T. K., Adjemian, J., Zhang, H., Wang, P., and Zhang, Q. (2020). Incidence and prevalence of nontuberculous mycobacterial lung disease in a large U.S. managed care health plan, 2008-2015. Ann. Am. Thorac. Soc. 17, 178–185. doi: 10.1513/AnnalsATS.201804-236OC

PubMed Abstract | CrossRef Full Text | Google Scholar

Wood, D. E., Lu, J., and Langmead, B. (2019). Improved metagenomic analysis with kraken 2. Genome Biol. 20:257. doi: 10.1186/s13059-019-1891-0

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhang, C., Qin, K., Struewing, I., Buse, H., Santo Domingo, J., Lytle, D., et al. (2021). The bacterial community diversity of bathroom hot tap water was significantly lower than that of cold tap and shower water. Front. Microbiol. 12:625324. doi: 10.3389/fmicb.2021.625324

PubMed Abstract | CrossRef Full Text | Google Scholar

Zlatanović, L., Van Der Hoek, J. P., and Vreeburg, J. H. G. (2017). An experimental study on the influence of water stagnation and temperature change on water quality in a full-scale domestic drinking water system. Water Res. 123, 761–772. doi: 10.1016/j.watres.2017.07.019

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: Legionella pneumophila , premise plumbing, microbial communities, opportunistic pathogens, free-living amoeba

Citation: Gomez-Alvarez V, Ryu H, Tang M, McNeely M, Muhlen C, Urbanic M, Williams D, Lytle D and Boczek L (2023) Assessing residential activity in a home plumbing system simulator: monitoring the occurrence and relationship of major opportunistic pathogens and phagocytic amoebas. Front. Microbiol. 14:1260460. doi: 10.3389/fmicb.2023.1260460

Received: 17 July 2023; Accepted: 28 September 2023;
Published: 17 October 2023.

Edited by:

Geoffrey James Puzon, CSIRO Land and Water, Australia

Reviewed by:

Diane McDougald, University of Technology Sydney, Australia
Nicholas John Ashbolt, Southern Cross University, Australia
Isabel Douterelo, The University of Sheffield, United Kingdom

Copyright © 2023 Gomez-Alvarez, Ryu, Tang, McNeely, Muhlen, Urbanic, Williams, Lytle and Boczek. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Vicente Gomez-Alvarez, R29tZXotQWx2YXJlei5WaWNlbnRlQGVwYS5nb3Y=

Present address: Min Tang, CDM Smith, Cincinnati, OH, United States

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.