AUTHOR=Harb Elise N. , Sawai Elsie Shin , Wildsoet Christine F. TITLE=Indoor and outdoor human behavior and myopia: an objective and dynamic study JOURNAL=Frontiers in Medicine VOLUME=10 YEAR=2023 URL=https://www.frontiersin.org/journals/medicine/articles/10.3389/fmed.2023.1270454 DOI=10.3389/fmed.2023.1270454 ISSN=2296-858X ABSTRACT=Significance

Myopia holds significant public health concern given its social, ocular disease and economic burdens. Although environmental factors are primarily to blame for the rapid rise in prevalence, key risk factors remain unresolved.

Purpose

The aim of this study was to objectively characterize, using a wearable technology, the temporal indoor and outdoor behavioral patterns and associated environmental lighting characteristics of young myopic and nonmyopic University students.

Methods

Participants were recruited to continuously wear an Actiwatch for 3 weeks, during either or both academic and non-academic periods. The device allows continuous recording of activity and incident light. Recorded illuminance levels were used as a proxy for outdoors (>1,000 lux), with the dynamics (interval frequency and duration) of indoor and outdoor activities, as well as lighting characteristics derived. In addition, participant input regarding near work was obtained daily. Participants were classified by both myopia and axial length status (based on collected refractive error and biometry data) for the purpose of data analysis.

Result

A total of 55 students, aged 18 to 25 years of age, participated. Overall, the dosing of indoor and outdoor activities was similar across participants, regardless of myopia status, during the academic period. Nonetheless, an apparent difference in the timing of outdoor activities was noted with myopes going outdoors later in the day, particularly during the weekend (p = 0.03). While a trend was observed between increased lighting levels experienced outdoors and shorter axial lengths, there was no significant relationship with myopia status. Noteworthy, participants generally significantly overestimated time spent outdoors, compared to Actiwatch-derived estimates of the same.

Conclusion

While the findings from this cohort of young adult students did not reveal substantial myopia-related differences in behavior, the power of a more objective and dynamic approach to quantifying behavior cannot be understated, providing argument for general adoption of wearable technologies in future clinical myopia studies.