AUTHOR=Singer Clara , Luxenburg Osnat , Rosen Shani , Vaknin Sharona , Saban Mor TITLE=Advancing acceptance: assessing acceptance of the ESR iGuide clinical decision support system for improved computed tomography test justification JOURNAL=Frontiers in Medicine VOLUME=10 YEAR=2023 URL=https://www.frontiersin.org/journals/medicine/articles/10.3389/fmed.2023.1234597 DOI=10.3389/fmed.2023.1234597 ISSN=2296-858X ABSTRACT=Background

A clinical decision support system (CDSS), the European Society of Radiologists (ESR) iGuide, was developed to address gaps in the availability and use of effective imaging referral guidelines.

Aim

This study aimed to assess the appropriateness of computed tomography (CT) exams with and without ESR iGuide use, as well as the usability and acceptance of the physician systems.

Methods

A retrospective single-center study was conducted in which data from 278 consecutive CT tests referred by physicians were collected in the first phase (T1), and physicians used the ESR iGuide system for imaging referrals in the second phase (T2; n = 85). The appropriateness of imaging referrals in each phase was assessed by two experts, and physicians completed the System Usability Scale.

Results

The mean appropriateness level on a scale of 0–9 was 6.62 ± 2.69 at T1 and 7.88 ± 1.4 at T2. When using a binary variable (0–6 = non-appropriate; 7–9 = appropriate), 70.14% of cases were found appropriate at T1 and 96.47% at T2. Surgery physician specialty and post-intervention phase showed a higher likelihood of ordering an appropriate test (p = 0.0045 and p = 0.0003, respectively). However, the questionnaire results indicated low system trust and minimal clinical value, with all physicians indicating they would not recommend collegial use (100%).

Conclusion

The study suggests that ESR iGuide can effectively guide the selection of appropriate imaging tests. However, physicians showed low system trust and use, indicating a need for further understanding of CDSS acceptance properties. Maximizing CDSS potential could result in crucial decision-support compliance and promotion of appropriate imaging.