AUTHOR=Meeusen Jeffrey W. , Stämmler Frank , Dasari Surendra , Schiffer Eric , Lieske John C. TITLE=Serum myo-inositol and valine improve metabolomic-based estimated glomerular filtration rate among kidney transplant recipients JOURNAL=Frontiers in Medicine VOLUME=9 YEAR=2022 URL=https://www.frontiersin.org/journals/medicine/articles/10.3389/fmed.2022.988989 DOI=10.3389/fmed.2022.988989 ISSN=2296-858X ABSTRACT=Background

Close monitoring of glomerular filtration rate (GFR) is essential for the management of patients post kidney transplantation. Measured GFR (mGFR), the gold standard, is not readily accessible in most centers. Furthermore, the performance of new estimated GFR (eGFR) equations based upon creatinine and/or cystatin C have not been validated in kidney transplant patients. Here we evaluate a recently published eGFR equation using cystatin C, creatinine, myo-inositol and valine as measured by nuclear magnetic resonance (eGFRNMR).

Methods

Residual sera was obtained from a cohort of patients with clinically ordered iothalamate renal clearance mGFR (n = 602). Kidney transplant recipients accounted for 220 (37%) of participants.

Results

Compared to mGFR, there was no significant bias for eGFRcr or eGFRNMR, while eGFRcr-cys significantly underestimated mGFR. P30 values were similar for all eGFR. P15 was significantly higher for eGFRNMR compared to eGFRcr, while the P15 for eGFRcr-cys only improved among patients without a kidney transplant. Agreement with mGFR CKD stages of <15, 30, 45, 60, and 90 ml/min/1.73 m2 was identical for eGFRcr and eGFRcr-cys (61.8%, both cases) while eGFRNMR was significantly higher (66.4%) among patients with a kidney transplant.

Conclusion

The 2021 CKD-EPI eGFRcr and eGFRcr-cys have similar bias, P15, and agreement while eGFRNMR more closely matched mGFR with the strongest improvement among kidney transplant recipients.