UF insufficiency is a major limitation in PD efficiency and sustainability. Our study object to investigate the efficacy of intraperitoneal inflammation marker, IL-6 level as a predictor of UF insufficiency in continuous ambulatory peritoneal dialysis (CAPD) patients.
Stable prevalent CAPD patients were enrolled in this prospective study. IL-6 concentration in the overnight effluent was determined and expressed as the IL-6 appearance rate (IL-6 AR). Patients were divided into two groups according to the median of IL-6 AR and prospectively followed up until death, transfer to permanent HD, recovery of renal function, kidney transplantation, transfer to other centers, lost to follow-up or to the end of study (January 31, 2021). Factors associated with UF capacity as well as dialysate IL-6 AR were assessed by multivariable linear regression. Cox proportional hazards model was used to examine the association between dialysate IL-6 AR and UF insufficiency.
A total of 291 PD patients were enrolled, including 148 males (51%) with a mean age of 56.6 ± 14.1 years and a median PD duration of 33.4 (12.7–57.5) months. No correlation was found between dialysate IL-6 AR and UF capacity at baseline. PD duration was found positively correlated with baseline dialysate IL-6 AR, while 24h urine volume was negatively correlated with baseline dialysate IL-6 AR (
Our study suggested that the dialysate IL-6 AR could be a potential predictor of UF insufficiency in patients undergoing PD.