Skip to main content

ORIGINAL RESEARCH article

Front. Med., 20 August 2021
Sec. Nephrology

Safe Limits of Contrast Media for Contrast-Induced Nephropathy: A Multicenter Prospective Cohort Study

\nZhiqiang Nie,Zhiqiang Nie1,2Yong LiuYong Liu3Chao WangChao Wang1Guoli SunGuoli Sun3Guo ChenGuo Chen3Zuxun Lu
Zuxun Lu1*
  • 1Department of Social Medicine and Health Management, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
  • 2Department of Epidemiology, Guangdong Provincial Key Laboratory of Coronary Heart Disease Prevention, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
  • 3Department of Cardiology, Guangdong Provincial Key Laboratory of Coronary Heart Disease Prevention, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China

Background: The safe level of contrast media volume (CV) is an important modifiable risk factor for contrast-induced nephropathy (CIN). The safe limit of CV remains unclear and is limited to single-center studies. Our objective was to determine the association between the ratio of contrast volume-to-glomerular filtration (CV/GFR) and CIN in patients undergoing coronary angiography (CAG) or percutaneous coronary intervention (PCI).

Methods: We assessed the association between CV/GFR and the risk of CIN in 4,254 patients undergoing CAG or PCI from the year 2013 to 2016 and enrolled in the REICIN (REduction of rIsk for Contrast-Induced Nephropathy), a prospective, multicenter, observational cohort study. CV/GFR was calculated at the five primary GFR equation.

Results: Sixty-nine (1.7%) patients with a median contrast volume-to-chronic kidney disease epidemiology collaboration (CV/CKD-EPI) ratio of 2.16 (1.30–3.93) have suffered from CIN. The CV/CKD-EPI demonstrated the best performance of model fit, discrimination (area under curve = 0.736), calibration, reclassification, and equation conciseness (1 variable). The CV/CKD-EPI ≥1.78 was the statistical significance associated with CIN [adjusted odds ratio, 4.64 (2.84–7.56); p < 0.001]. Furthermore, similar results were found in the subgroup analyses.

Conclusions: The CV/CKD-EPI showed the best performance in patients undergoing CAG or PCI. CV/CKD-EPI ≥1.78 could be a more reliable and convenient predictor of CIN. Intraprocedural preventive measures should include a priori calculation of CV/GFR to limit contrast volume.

Introduction

Contrast-induced nephropathy (CIN) is a common but serious complication of coronary angiography (CAG) and/or percutaneous coronary intervention (PCI). CIN is defined as a decline in kidney function that occurred in a narrow time window after administration of iodinated contrast agent (1). Although several factors have been identified as risk factors of CIN, such as chronic kidney disease (CKD), diabetes mellitus, hemodynamic instability, gender, and age, they are not typically modifiable. Recently, the importance of modifiable influencing factors of CIN, including the safe level of contrast media volume (CV) has been increasingly recognized to minimize the nephrotoxicity (2).

Contrast media is mainly excreted via kidneys pharmacokinetically. Several previous studies have investigated the safe level of CV for CIN after CAG or PCI using a single pharmacokinetic index, such as contrast volume-to-creatinine clearance (CV/CrCl) or contrast volume-to-glomerular filtration rate (CV/GFR) (310). Smaller CV/GFR cutoffs, corresponding to lower levels of CV, has been used to facilitate clinical decision. According to the European Society of Cardiology/European Association for Cardio-Thoracic Surgery (ESC/EACTS) guidelines (11), the recommended cutoff value of CV/GFR was 3.7, and a CV/GFR value >3.7 increases the risk of CIN (within 24 h) significantly (3, 12). But in real clinical practices, when the ratio is <3.7, a significant number of patients still develop CIN. Another U.S. cohort study has demonstrated that CV/GFR >3 dramatically elevated the risk of CIN (13), meanwhile, further cutoff should be optimized in the range of CV/GFR <3. Our previous study has suggested that CV/GFR >2.62 was a significant and independent predictor of CIN (within 72 h), but these data were collected in a single center (7). Thus far, there has been no prospective cohort study with multicenter recruitment to validate the cutoff value of CV/GFR (14, 15). On the other hand, since the existing recommended CV/GFR cutoffs were determined based on Canadian and American populations, whether these values were also appropriate for Chinese patients remain controversial.

Meanwhile, there are 10 algorithms to calculate GFR (Supplementary Table 1), such as Cockcroft–Gault (C-G) (16), modification of diet in renal disease (MDRD) (13, 17), chronic kidney disease epidemiology collaboration (CKD-EPI) (18), etc. They were developed based on different populations. For instance, C-G was derived from natural population, while MDRD and CKD-EPI were derived from CKD population. Previous studies show conflicting results because of different study populations, different gold standard GFR measurements, and different creatinine assay calibration (19, 20). However, there is no study that assessed the utility of all the 10 algorithms in CAG or PCI patients. Evidence-based recommendations considering multiple estimated GFR (eGFR) algorithm to guide the best CV/GFR strategies for CAG or PCI patients are still lacking. Therefore, we aimed to determine the optimal CV/GFR equation in predicting CIN and to define the safe dose of contrast media on the basis of GFR in this prospective study.

Methods

Study Population

The REduction of rIsk for Contrast-Induced Nephropathy (REICIN) study (trial registration: ClinicalTrials.govNCT01402232) is a prospective, multicenter, observational cohort study that recruited patients referred for CAG or PCI in 12 hospitals in Guangdong, Fujian, and Xinjiang, China, from January 2013 to February 2016 (follow-up is ongoing). Details of the site investigators and hospitals are provided in Supplementary Table 2. Details of the study procedure and inclusion and exclusion criteria are mentioned in Supplementary Figure 1. The study protocol was approved by the institutional Ethics Research Committee of Guangdong General Hospital (no. GDREC2012141H). All patients gave written informed consent before participating in this study.

Patient Management and Data Collection

The selection of contrast media was at the discretion of the operating physician within the dictates of the individual hospital policy. CV was expressed only in terms of volume in milliliters in this study because the CM concentration used during coronary procedures usually varies within narrow ranges, i.e., 320–370 mg I/ml as in the previous study (3, 13). CAG was performed according to standard clinical practice, using standard guide catheters, guidewires, balloon catheters, and stents via the femoral or radial approach. The most recent preoperative serum creatinine level and other laboratory biomarkers were defined as the baseline value. Measurements were repeated after CAG or PCI on the first, second, and third postoperative days. The beginning and end time of CAG or PCI were recorded. PCI techniques were selected at the discretion of the interventional cardiologist. We also collected the demographic data of patients and procedural characteristics from original records and hospitals' electronic medical records.

Study Endpoints and CV/GFR

The primary outcome of this analysis was CIN, which was defined as an impairment in renal function resulting in ≥0.5 mg/dl absolute increase in serum creatinine from baseline within 24–48 h. For each patient, we, respectively, estimated volume-to-GFR with five equations: contrast volume-to-chronic kidney disease epidemiology collaboration (CV/CKD-EPI) (18, 19, 21), contrast volume–to–Cockcroft–Gault (CV/C-G) (16), contrast volume-to-full age spectrum (CV/FAS) (22), contrast volume-to-modification of diet in renal disease study (CV/MDRD) (23, 24), and contrast volume-to-abbreviated modification of diet in renal disease study (CV/aMDRD) (25) (Supplementary Table 1). Because C-G has been conventionally used for evaluating the renal dosing (26) and CKD-EPI was established on minimalist clinical measurements, these two results were preferentially reported. The Berlin Initiative Study 1 (BIS1) and revised Lund-Malmö (LM-rev) algorithms were not included in the primary analysis because of their poor predictive performance [area under the receiver operating characteristics curve (AUC) <0.70], and BIS1 is only applicable for the elderly. The isotope dilution mass spectrometry (MDRD-IDMS) algorithm was not included because GFR was measured by the Roche enzymatic method but not IDMS in this algorithm. MDRD7-cn and aMDRD-cn were not analyzed since they were same algorithms with different coefficients, thus exhibiting the same predictive performance. Because of these limitations, we rule out the five algorithms of GFR equation.

Statistical Analyses

Missing data were imputed using the multivariate imputations by chained equations method with missing-at-random assumptions (Supplementary Table 3). Five copies of the data, each with missing values imputed, estimates of the parameters of interest were averaged across the copies. All results shown are the results after the multiple imputations of data (Table 1).

TABLE 1
www.frontiersin.org

Table 1. Baseline characteristics of patients who developed CIN.

Continuous variables are expressed as mean ± standard deviation, and discrete variables are described as frequency counts and percentages. The differences in continuous variables were analyzed with the t-test and Wilcoxon test as needed. Discrete variables between groups were evaluated by the Chi-square test and Fisher's exact test. We estimated empirical AUC for comparing CV/C-G, CV/CKD-EPI, CV/FAS, CV/MDRD7, and CV/aMDRD with bootstrap method (1,000 resamples). Receiver operator characteristic (ROC) curve analysis was used to determine the optimal cut-point for CV/GFR in this population and compared AUC with the DeLong and Clarke-Pearson methods (Figure 1). Additionally, we modeled CV/CKD-EPI as restricted quadratic splines with knots at the 5, 50, and 95th percentiles of its distribution to provide a smooth and flexible description of the dose–response relationship between CV/CKD-EPI and CIN (Figure 2). Risk factors were initially screened for univariate association with CV/CKD-EPI, and external multivariable logistics regression (according to non-significant multilevel effect on collaboration centers with an intraclass correlation coefficient of 0.005; data not shown) adjusted for other important baseline characteristics was identified in a forward stepwise manner using a p-value criterion of <0.05 (Table 1). The optimal threshold was determined using an ROC curve analysis following Youden's index. AUC was evaluated for discrimination, and Hosmer–Lemeshow (H-L) statistic, Akaike information criteria (AIC), the Brier score were applied to compare the calibration. The goodness of reclassification was evaluated by integrated discrimination improvement (IDI), and the category net reclassification index (NRI) was calculated (Table 2). We also tested the joint association between CV/CKD-EPI cutoffs according to the joint distribution of subgroups (Figure 3): elderly adult, patients for segment elevated myocardial infarction (STEMI), emergent PCI, patients with cardiogenic shock, left ventricular ejection fraction (LVEF) <40, and high risk level of Mehran score. Measures of interaction for the primary outcome are presented on multiplicative scales and multiplicative scale (27, 28). Interaction contrast ratio with 95% confidence interval (CI) was used to evaluate additive interaction. All analyses were performed using SAS software v9.4 (SAS, Cary, North Carolina) and R v3.6.0 (R Foundation for Statistical Computing, Vienna, Austria).

FIGURE 1
www.frontiersin.org

Figure 1. ROC curve. ROC curve to evaluate the diagnostic performance of the ratio of CV/GFR to predict CIN according to the different equations (CKD-EPI, C-G, FAS, MDRD7, and aMDRD). aMDRD, abbreviated modification of diet in renal disease; AUC, area under the receiver operating characteristics curve; C-G, cockcroft–gault; CKD-EPI, chronic kidney disease epidemiology collaboration; FAS, full age spectrum; MDRD, modification of diet in renal disease study.

FIGURE 2
www.frontiersin.org

Figure 2. Restricted cubic spline of CV/CKD-EPI ratio and CIN. CV/CKD-EPI, contrast volume to chronic kidney disease epidemiology collaboration; CIN, contrast-induced nephropathy; OR, odds ratio.

TABLE 2
www.frontiersin.org

Table 2. Comparison of the five equations of CIN using IDI and NRI.

FIGURE 3
www.frontiersin.org

Figure 3. Incidence and interaction of CIN according to joint distribution of CV/CKD-EPI cutoff 1.78 and patients with elder age (A), elective PCI (B), cardiogenic shock (C), LVEF (D), high-risk level of Mehran score (E), and STEMI (F). Interaction effects were calculated by multivariate model adjusted for covariates (forward stepwise method): age, anemia, cardiogenic shock, CHF, HF, hypoalbuminemia, peri-hypotension, peri-IABP, LVEF <40%, preprocedural plasma glucose, min of hemoglobin, Hct, BUN, ALB, CK, CK-MB, diseased multivessel, PCI, number of stents, emergent PCI, Mehran integer score, and exceeding MACD. CV/CKD-EPI, contrast volume to chronic kidney disease epidemiology collaboration; CIN, contrast-induced nephropathy; LVEF, left ventricular ejection fraction; STEMI, segment elevated myocardial infarction.

Sample Size Consideration

The post hoc sample size was calculated according to the rule of thumb of Vittinghoff et al., Peduzzi, and Harrell et al. (2931), namely, the number of events per variable (EPV) of 5 to 10 or greater was applied for the multivariable regression model. We considered six significant factors in the final multivariable model (Table 3); this requires a sample size of 30–60 cases. Our study has sufficient data for sample size calculation.

TABLE 3
www.frontiersin.org

Table 3. Multivariable logistics model association between CIN and CV/CKD-EPI ratio.

Results

Clinical and Laboratory Characteristics of the Patients

We consecutively included a total of 4,254 patients who underwent CAG during the study period (Supplementary Figure 1). Of them, 69 patients (1.7%) suffered from CIN. Baseline clinical and angiographic characteristics, as well as the main procedural data of these patients, are listed in Table 1. The median contrast dose was 100 ml (interquartile range: 50–125 ml). The baseline characteristics of the patients with and with no CIN are shown in Table 1. The CIN patients were more likely to be elderly and had anemia, cardiogenic shock, congestive heart failure (CHF), cardiovascular disease (CVD), heart failure (HF), hypoalbuminemia, peri-hypotension, peri-intra-aortic balloon pump (peri-IABP), and LVEF below 40%. The patients with CIN were more likely to have lower laboratory measurements at min of hemoglobin (the lowest value of multiple hemoglobin check after admission), hematocrit (Hct), albumin (ALB) and higher preprocedural plasma glucose, blood urea nitrogen (BUN), creatine kinase (CK), creatine kinase-muscle/brain (CK-MB), as well as a higher CV/GFR ratio. They were more likely to have multivessel CAD and to receive PCI, stent implantation, emergent PCI, and exceeding maximum contrast dose (MACD). The median CV/CKD-EPI was 2.16 (1.30–3.93) for those with CIN and 1.15 (0.66–1.79) for those without CIN (p < 0.001). The median CV/C-G in patients with CIN [2.50 (1.45–4.39)] was significantly higher than those without CIN [1.27 (0.74–2.01)] (p < 0.001).

CV/GFR Predicting CIN

ROC analysis demonstrated that the AUC for the CV/CKD-EPI was 0.736, and the optimal cutoff was 1.78 for CIN (Figure 1). CV/CKD-EPI was shown as the most concise equation requiring only one variable. At this cutoff value, the sensitivity and specificity were 61% and 75%, respectively. The equation CV/C-G showed a high discrimination as CV/CKD-EPI (AUC = 0.720) and showed a high reclassification as CV/CKD-EPI (IDI = 0.012, NRI = −0.162) with an optimal cutoff of 2.23 (Table 2). CV/C-G exhibited 59% sensitivity and 80% specificity for detecting CIN. However, CV/C-G showed lower calibration than CV/CKD-EPI as its higher AIC and Brier score; meanwhile, two variables are needed in the CV/C-G equation. In addition, the discrimination, calibration, and reclassification ability of CV/FAS, CV/MDRD, and CV/aMDRD were significantly lower than those of CV/CKD-EPI. CV/MDRD also need two more variables in the equation.

A non-linear association between CV/CKD-EPI and CIN was demonstrated (Figure 2). Odds of CIN were low, and linear association until the CV/CKD-EPI was 1.78, at which point a positive exponential association emerged. According to the univariate logistic regression analysis, a CV/CKD-EPI >1.78 was a significant predictor of CIN [odds ratio (OR) = 4.64, 95% CI = 2.84–7.56, p < 0.001) (Table 3). In the multivariable analysis, CV/CKD-EPI >1.78 (OR = 2.66, 95% CI = 1.50–4.72, p < 0.001) remained an independent risk factor for CIN after adjusting for other potential confounders.

On the other hand, CV/GFR on the basis of renal function performed better MACD in predicting CIN in this study (AUC = 0.736 vs. AUC = 0.552, p < 0.001).

Impact of CV/GFR and CIN on Subgroup

When the incidence of CIN was assessed in the subsets stratified by age (<60 vs. ≥60), a higher incidence of CIN was evident in the CV/CKD-EPI ≥1.78(p < 0.001) (Figure 3). Similar trends were observed in the categories of PCI status (elective vs. acute), LVEF (<40 vs. ≥40), and STEMI (with vs. without). However, it was observed only in patients with no cardiogenic shock (p < 0.001) or high-risk level of Mehran score. We observed a significant additive interaction between CV/CKD-EPI and level of Mehran score, with interaction contrast ratio of 9.13 (95% CI = 2.19–16.07), p = 0.009. Notably, adjusted ORs for CV/CKD-EPI ≥1.78 in predicting CIN for the low-risk to the high-risk level of Mehran score were 3.51 (95% CI = 1.62–7.60) and 13.34 (95% CI = 6.77–26.25) (data not shown).

Discussion

Key Findings

The CV/CKD-EPI was a simple but high-efficiency tool for guiding contrast dosing in patients undergoing CAG or PCI. It was superior to CV/C-G, CV/FAS, CV/MDRD, and CV/aMDRD in model fit performance. The CV/CKD-EPI ≥1.78 was associated with a high incidence of CIN. Similar results were found in the subgroup analysis, especially in high-risk level of Mehran score.

CIN Definition and Incidence

The incidence of CIN varies widely across studies, depending on the varying patient samples, different baseline risk factors, and the disparities in definitions (32). Gurm et al. defined CIN as ≥0.5 mg/dl absolute increase in Scr from baseline, but creatinine collected in the follow-up period was variable because of different lengths of hospital stay (13). Laskey et al. defined CIN as an absolute increase in serum creatinine of >0.5 mg/dl in 24–48 h. Because there was no widely accepted alternative term, our research defined the CIN term as Laskey (3).

CV Dose

The CV administered during a cardiovascular procedure is crucial. Over the past years, the suggested volume cutoff has varied from a fixed volume of 125 ml (33) to an relative volume of MACD (4) or a relative volume of GFR. MACD was defined by an empiric formula of 5 ml of body weight (kg)/baseline Scr (mg/dl), with a maximum dose of 300 ml. It is hypothesized that contrast dose only associated with body weight and the baseline kidney function, but there was no scientific basis. Even though MACD is frequently used in clinical practices, the CIN still occurs even when MACD is not exceeded, such as the incidence of 11% found by Ogata et al. (34) and 13% concluded by Marenzi et al.

On the contrary, CV/GFR on the basis of renal function showed better performance than MACD in predicting CIN in our study, which is similar to previous studies (13). Raposeiras-Roubin et al., Nyman et al., Laskey et al., and Gurm et al. were the pioneers to propose the use of CV/GFR (3, 13, 17, 35). Raposeiras-Roubin et al. founded there were no differences in the discriminative ability to predict CIN between the three GFR equations (CV/MDRD, CV/C-G, and CV/CKD-EPI) (17) based on CAG patients with acute coronary syndrome from a retrospective cohort in Spain. Nyman et al. reported that at fixed CV/C-G ratios (from 3:1 ratio to 1:2 ratio), CIN risk increased marginally with decreasing eGFR among patients who underwent CAG for STEMI in a Swedish cohort study (35). Laskey et al. recommended a CV/C-G cutoff value >3.7 for evaluating the safe volume, but they also stated that a small but significant number of patients would develop CIN even when the ratio is <3.7. It is consistent with our finding that 17% (12/69) true-positive CIN patients with a CV/C-G value below 3.7 were misclassified to negative. Our results provided further support for the hypothesis that lower contrast media volume by CV/CKD-EPI exceeding 1.78 was an independent predictor of CIN (7).

Overall, routine measurements of the maximum limit of contrast volume in CAG or PCI, either using the MACD or CV/GFR method, are essential and should be recommended before the procedure.

GFR Algorithm

When defining the ratio for contrast dosing, the variety of GFR formula should be taken into account, such as CV/CKD-EPI (18, 19, 21), CV/C-G (16), CV/FAS (22), CV/MDRD (23, 24), and CV/aMDRD (25), which were generally seen in clinic. It is widely accepted that CKD-EPI gives the best estimation of GFR based on a gold standard measurement using I-iothalamate (19). However, to our knowledge, these equations have not been externally validated to calculate the cutoff ratio in CAG or PCI patients together. By comparing the above five equations of contrast dosing ratio, we found that CV/CKD-EPI was the best equation for guiding reduction in the contrast nephrotoxicity.

Strengths and Limitations

Our multicenter prospective cohort study supports the need for minimizing contrast dose in CAG or PCI procedures. The usage of CV/CKD-EPI follows the basic pharmacological principles, and our findings demonstrate a consistent relationship between the high incidence of CIN and CV/CKD-EPI in total patients and in subgroups patients. Furthermore, the inherent simplicity and convenience of calculating CV/CKD-EPI make this indicator an easy method in routine clinical practice.

This study possessed several limitations. First, the cohort included Chinese patients only, which may potentially limit the generalizability of our results to other countries and territories. On the other hand, because of the relative large population, the prospective nature, and the multicenter recruitment, our results may provide more reliable evidence than previous single-center studies (7, 9, 10, 36, 37). Second, the CV/GFR was computed using five primary formulas, rather than a direct measurement. Despite this, most of the equations have been established and validated in Western countries, and the MDRD-cn formula was the same accuracy as MDRD. Third, patients who were excluded due to absence of post-PCI serum creatinine ascertainment were, in general, healthier than those in this cohort, and this might introduce potential selection bias. However, we observed a similar relationship in patients who underwent elective PCI and had less baseline risk factors of renal complications.

Conclusions

In conclusion, intraprocedural preventive measures should include a priori calculation of CV/GFR to limit contrast volume, and the equation of CKD-EPI showed better performance in estimating GFR than others. Future guidelines to prevent CIN should consider incorporating a more objective measurement of CV such as CV/GFR.

Data Availability Statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author/s.

Ethics Statement

The studies involving human participants were reviewed and approved by the institutional Ethics Research Committee of Guangdong General Hospital (No. GDREC2012141H). The patients/participants provided their written informed consent to participate in this study. The patients/participants provided their written informed consent to participate in this study.

Author Contributions

ZN and ZL conceived and designed the research. ZN drafted the manuscript, analyzed, and interpreted the data. YL, CW, GC, and GS collected data and revised the manuscript critically for important intellectual content. All authors contributed to the article and approved the submitted version.

Funding

This study was supported by grants from the Natural Science Foundation of Guangdong Province (2020A1515010743), the National Social Science Foundation of China (18ZDA085), and the National Science Foundation of China (81670339).

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary Material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fmed.2021.701062/full#supplementary-material

References

1. Erselcan T, Egilmez H, Hasbek Z, Tandogan I. Contrast-induced nephropathy: controlled study by differential GFR measurement in hospitalized patients. Acta Radiol. (2012) 53:228–32. doi: 10.1258/ar.2011.110412

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Gross JL, Friedman R, Silveiro SP. Preventing nephropathy induced by contrast medium. N Engl J Med. (2006) 354:1853–5. doi: 10.1056/NEJMc060405

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Laskey WK, Jenkins C, Selzer F, Marroquin OC, Wilensky RL, Glaser R, et al. Volume-to-creatinine clearance ratio: a pharmacokinetically based risk factor for prediction of early creatinine increase after percutaneous coronary intervention. J Am Coll Cardiol. (2007) 50:584–90. doi: 10.1016/j.jacc.2007.03.058

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Marenzi G, Assanelli E, Campodonico J, Lauri G, Marana I, De Metrio M, et al. Contrast volume during primary percutaneous coronary intervention and subsequent contrast-induced nephropathy and mortality. Ann Intern Med. (2009) 150:170–7. doi: 10.7326/0003-4819-150-3-200902030-00006

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Mager A, Vaknin Assa H, Lev EI, Bental T, Assali A, Kornowski R. The ratio of contrast volume to glomerular filtration rate predicts outcomes after percutaneous coronary intervention for ST-segment elevation acute myocardial infarction. Catheter Cardiovasc Interv. (2011) 78:198–201. doi: 10.1002/ccd.22828

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Liu Y, Tan N, Zhou YL, He PC, Luo JF, Chen JY. The contrast medium volume to estimated glomerular filtration rate ratio as a predictor of contrast-induced nephropathy after primary percutaneous coronary intervention. Int Urol Nephrol. (2012) 44:221–9. doi: 10.1007/s11255-011-9910-4

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Tan N, Liu Y, Zhou YL, He PC, Yang JQ, Luo JF, et al. Contrast medium volume to creatinine clearance ratio: a predictor of contrast-induced nephropathy in the first 72 hours following percutaneous coronary intervention. Catheter Cardiovasc Interv. (2012) 79:70–5. doi: 10.1002/ccd.23048

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Liu Y, Chen JY, Tan N, Zhou YL, Yu DQ, Chen ZJ, et al. Safe limits of contrast vary with hydration volume for prevention of contrast-induced nephropathy after coronary angiography among patients with a relatively low risk of contrast-induced nephropathy. Circ Cardiovasc Interv. (2015) 8:e001859. doi: 10.1161/CIRCINTERVENTIONS.114.001859

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Liu Y, Liu YH, Chen JY, Tan N, Zhou YL, Duan CY, et al. Safe contrast volumes for preventing contrast-induced nephropathy in elderly patients with relatively normal renal function during percutaneous coronary intervention. Medicine. (2015) 94:e615. doi: 10.1097/MD.0000000000000615

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Barbieri L, Verdoia M, Marino P, Suryapranata H, De Luca G, Novara Atherosclerosis Study Group. Contrast volume to creatinine clearance ratio for the prediction of contrast-induced nephropathy in patients undergoing coronary angiography or percutaneous intervention. Eur J Prev Cardiol. (2016) 23:931–7. doi: 10.1177/2047487315614493

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Neumann FJ, Sousa-Uva M, Ahlsson A, Alfonso F, Banning AP, Benedetto U, et al. 2018 ESC/EACTS guidelines on myocardial revascularization. Kardiol Pol. (2018) 76:1585–664. doi: 10.5603/KP.2018.0228

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Neumann FJ, Sousa-Uva M, Ahlsson A, Alfonso F, Banning AP, Benedetto U, et al. 2018 ESC/EACTS Guidelines on myocardial revascularization. Eur Heart J. (2018) 40:87–165. doi: 10.1093/eurheartj/ehy394

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Gurm HS, Dixon SR, Smith DE, Share D, Lalonde T, Greenbaum A, et al. Renal function-based contrast dosing to define safe limits of radiographic contrast media in patients undergoing percutaneous coronary interventions. J Am Coll Cardiol. (2011) 58:907–14. doi: 10.1016/j.jacc.2011.05.023

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Allen DW, Ma B, Leung KC, Graham MM, Pannu N, Traboulsi M, et al. Risk prediction models for contrast-induced acute kidney injury accompanying cardiac catheterization: systematic review and meta-analysis. Can J Cardiol. (2017) 33:724–36. doi: 10.1016/j.cjca.2017.01.018

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Silver SA, Shah PM, Chertow GM, Harel S, Wald R, Harel Z. Risk prediction models for contrast induced nephropathy: systematic review. BMJ. (2015) 351:h4395. doi: 10.1136/bmj.h4395

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Cockcroft DW, Gault MH. Prediction of creatinine clearance from serum creatinine. Nephron. (1976) 16:31–41. doi: 10.1159/000180580

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Raposeiras-Roubín S, Abu-Assi E, Ocaranza-Sánchez R, Alvarez-Álvarez B, Cambeiro-González C, Fandiño-Vaquero R, et al. Dosing of iodinated contrast volume: a new simple algorithm to stratify the risk of contrast-induced nephropathy in patients with acute coronary syndrome. Catheter Cardiovasc Interv. (2013) 82:888–97. doi: 10.1002/ccd.24847

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Levey AS, Stevens LA, Schmid CH, Zhang YL, Castro AF 3rd, Feldman HI, et al. A new equation to estimate glomerular filtration rate. Ann Intern Med. (2009) 150:604–12. doi: 10.7326/0003-4819-150-9-200905050-00006

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Michels WM, Grootendorst DC, Verduijn M, Elliott EG, Dekker FW, Krediet RT. Performance of the cockcroft-Gault, MDRD, and new CKD-EPI formulas in relation to GFR, age, and body size. Clin J Am Soc Nephrol. (2010) 5:1003–9. doi: 10.2215/CJN.06870909

PubMed Abstract | CrossRef Full Text | Google Scholar

20. White CA, Huang D, Akbari A, Garland J, Knoll GA. Performance of creatinine-based estimates of GFR in kidney transplant recipients: a systematic review. Am J Kidney Dis. (2008) 51:1005–15. doi: 10.1053/j.ajkd.2008.02.308

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Selistre L, Rabilloud M, Cochat P, de Souza V, Iwaz J, Lemoine S, et al. Comparison of the schwartz and CKD-EPI equations for estimating glomerular filtration rate in children, adolescents, and adults: a retrospective cross-sectional study. PLoS Med. (2016) 13:e1001979. doi: 10.1371/journal.pmed.1001979

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Pottel H, Hoste L, Dubourg L, Ebert N, Schaeffner E, Eriksen BO, et al. An estimated glomerular filtration rate equation for the full age spectrum. Nephrol Dial Transplant. (2016) 31:798–806. doi: 10.1093/ndt/gfv454

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Levey AS, Bosch JP, Lewis JB, Greene T, Rogers N, Roth D. A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Modification of diet in renal disease study group. Ann Intern Med. (1999) 130:461–70. doi: 10.7326/0003-4819-130-6-199903160-00002

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Ma YC, Zuo L, Chen JH, Luo Q, Yu XQ, Li Y, et al. Modified glomerular filtration rate estimating equation for Chinese patients with chronic kidney disease. J Am Soc Nephrol. (2006) 17:2937–44. doi: 10.1681/ASN.2006040368

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Levey AS, Coresh J, Greene T, Marsh J, Stevens LA, Kusek JW, et al. Expressing the modification of diet in renal disease study equation for estimating glomerular filtration rate with standardized serum creatinine values. Clin Chem. (2007) 53:766–72. doi: 10.1373/clinchem.2006.077180

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Spruill WJ, Wade WE, Cobb HH 3rd. Continuing the use of the cockcroft-gault equation for drug dosing in patients with impaired renal function. Clin Pharmacol Ther. (2009) 86:468–70. doi: 10.1038/clpt.2009.187

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Liu X, Nie Z, Chen J, Guo X, Ou Y, Chen G, et al. Does maternal environmental tobacco smoke interact with social-demographics and environmental factors on congenital heart defects? Environ Pollut. (2018) 234:214–22. doi: 10.1016/j.envpol.2017.11.023

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Knol MJ, VanderWeele TJ, Groenwold RH, Klungel OH, Rovers MM, Grobbee DE. Estimating measures of interaction on an additive scale for preventive exposures. Eur J Epidemiol. (2011) 26:433–8. doi: 10.1007/s10654-011-9554-9

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Harrell FE Jr, Lee KL, Mark DB. Multivariable prognostic models: issues in developing models, evaluating assumptions and adequacy, and measuring and reducing errors. Stat Med. (1996) 15:361–87. doi: 10.1002/(SICI)1097-0258(19960229)15:4<361::AID-SIM168>3.0.CO;2-4

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Peduzzi P, Concato J, Feinstein AR, Holford TR. Importance of events per independent variable in proportional hazards regression analysis. II. Accuracy and precision of regression estimates. J Clin Epidemiol. (1995) 48:1503–10. doi: 10.1016/0895-4356(95)00048-8

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Vittinghoff E, McCulloch CE. Relaxing the rule of ten events per variable in logistic and cox regression. Am J Epidemiol. (2007) 165:710–8. doi: 10.1093/aje/kwk052

PubMed Abstract | CrossRef Full Text | Google Scholar

32. McCullough PA, Adam A, Becker CR, Davidson C, Lameire N, Stacul F, et al. Epidemiology prognostic implications of contrast-induced nephropathy. Am J Cardiol. (2006) 98:5K−13K. doi: 10.1016/j.amjcard.2006.01.022

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Taliercio CP, Vlietstra RE, Fisher LD, Burnett JC. Risks for renal dysfunction with cardiac angiography. Ann Intern Med. (1986) 104:501–4. doi: 10.7326/0003-4819-104-4-501

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Ogata N, Ikari Y, Nanasato M, Okutsu M, Kametani R, Abe M, et al. Safety margin of minimized contrast volume during percutaneous coronary intervention in patients with chronic kidney disease. Cardiovasc Interv Ther. (2014) 29:209–15. doi: 10.1007/s12928-014-0245-9

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Nyman U, Björk J, Aspelin P, Marenzi G. Contrast medium dose-to-GFR ratio: a measure of systemic exposure to predict contrast-induced nephropathy after percutaneous coronary intervention. Acta Radiol. (2008) 49:658–67. doi: 10.1080/02841850802050762

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Worasuwannarak S, Pornratanarangsi S. Prediction of contrast-induced nephropathy in diabetic patients undergoing elective cardiac catheterization or PCI: role of volume-to-creatinine clearance ratio and iodine dose-to-creatinine clearance ratio. J Med Assoc Thai. (2010) 93(Suppl. 1):S29–34.

PubMed Abstract | Google Scholar

37. Altmann DB, Zwas D, Spatz A, Bergman G, Spokojny A, Riva S, et al. Use of the contrast volume to estimated creatinine clearance ratio to predict renal failure after angiography. J Int Cardiol. (1997) 10:113–9. doi: 10.1111/j.1540-8183.1997.tb00018.x

CrossRef Full Text | Google Scholar

Keywords: contrast-induced nephropathy, coronary angiography, percutaneous coronary intervention, glomerular filtration rate, safe limits

Citation: Nie Z, Liu Y, Wang C, Sun G, Chen G and Lu Z (2021) Safe Limits of Contrast Media for Contrast-Induced Nephropathy: A Multicenter Prospective Cohort Study. Front. Med. 8:701062. doi: 10.3389/fmed.2021.701062

Received: 29 April 2021; Accepted: 05 July 2021;
Published: 20 August 2021.

Edited by:

Raymond Pranata, University of Pelita Harapan, Indonesia

Reviewed by:

Alexander Edo Tondas, Sriwijaya University, Indonesia
Amir Aziz Alkatiri, National Cardiovascular Center Harapan Kita, Indonesia
Antonia Anna Lukito, University of Pelita Harapan, Indonesia

Copyright © 2021 Nie, Liu, Wang, Sun, Chen and Lu. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Zuxun Lu, enV4dW5sdSYjeDAwMDQwO3lhaG9vLmNvbQ==

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.