AUTHOR=Beilhack Georg , Monteforte Rossella , Frommlet Florian , Gaggl Martina , Strassl Robert , Vychytil Andreas TITLE=Antibody Response and Safety After mRNA-1273 SARS-CoV-2 Vaccination in Peritoneal Dialysis Patients – the Vienna Cohort JOURNAL=Frontiers in Immunology VOLUME=12 YEAR=2021 URL=https://www.frontiersin.org/journals/immunology/articles/10.3389/fimmu.2021.780594 DOI=10.3389/fimmu.2021.780594 ISSN=1664-3224 ABSTRACT=Background

Dialysis patients are at high risk for a severe clinical course after infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Safety and early immune responses after mRNA-based vaccination have been reported mostly in patients on hemodialysis (HD), whereas reports of peritoneal dialysis (PD) patients remain rare.

Methods

In this retrospective observational study, 39 PD patients had received two doses of the mRNA-1273 Moderna® vaccine. We analyzed SARS-CoV-2 Spike (S) antibody titers 4 weeks after each dose of mRNA-1273 and report local and systemic side effects in PD patients that occurred within one week after each mRNA-1273 dose. Using a quantile regression model we examined factors that might influence SARS-CoV-2 S antibody levels in PD patients.

Results

Four weeks after the first dose of mRNA-1273 vaccine 33 of 39 (84.6%) PD patients seroconverted and presented with 6.62 U/mL (median; IQR 1.57-22.5) anti-SARS-CoV-2 S antibody titers. After the second dose, 38 of 39 (97.4%) PD patients developed anti-SARS-CoV-2 S antibodies and titers increased significantly (median 968 U/mL; IQR 422.5-2500). Pain at the injection site was the most common local adverse event (AE) (71%). Systemic AEs occurring after the first dose were mostly fatigue (33%) and headache (20%). No severe systemic AEs were reported after the first injection. After the second dose the incidence and the severity of the systemic AEs increased. The most common systemic AEs were: fatigue (40.5%), headache (22.5%), joint pain (20%), myalgia (17.5%) and fever (13%). Lower Davies Comorbidity Score (p=0.04) and shorter dialysis vintage (p=0.017) were associated with higher antibody titers after the first dose. Patients with higher antibody titers after the first dose tended to have higher antibody titers after the second dose (p=1.53x10-05).

Conclusions

Peritoneal dialysis patients in this cohort had a high seroconversion rate of 97.4%, showed high antibody titers after full vaccination and tolerated the anti-SARS-CoV-2 mRNA-1273 vaccine well without serious adverse events.