AUTHOR=Piza Cristina Frias Sartorelli de Toledo , Aranda Carolina Sanchez , Solé Dirceu , Jolles Stephen , Condino-Neto Antonio TITLE=Serum Protein Electrophoresis May Be Used as a Screening Tool for Antibody Deficiency in Children and Adolescents JOURNAL=Frontiers in Immunology VOLUME=12 YEAR=2021 URL=https://www.frontiersin.org/journals/immunology/articles/10.3389/fimmu.2021.712637 DOI=10.3389/fimmu.2021.712637 ISSN=1664-3224 ABSTRACT=Background

Patients with antibody deficiency may experience exceptionally long diagnostic delays, increasing the risk of life-threatening infections, end-organ damage, mortality, and health costs.

Objective

This study aimed to analyze serum protein electrophoresis and verify the correlation between calculated globulin (CG, total protein minus albumin levels) or electrophoretically determined serum gamma globulin fraction (Gamma) with IgG levels in children and adolescents under 18 years old (yo).

Methods

We analyzed serum protein electrophoresis (GC or Gamma) and IgG levels from 1215 children and adolescents under 18 yo, classified into 5 age groups. We verified the correlation between CG or Gamma with serum IgG levels.

Results

Serum IgG levels varied according to age groups (from 4.3 ± 2.3 g/l in children under 6 months old to 11.4 ± 3.2 g/l in adolescents in the 10-<18 yo group). CG sensitivity and specificity to detect IgG below the reference range for all patients were 93.1% and 81.8%, respectively, and varied according to age group. Gamma sensitivity and specificity for all patients were 100% and 87.8%, respectively, and varied according to age group as well. We found serum IgG levels below the age reference level in 29 patients (2.4% of the cases) using CG or Gamma levels.

Conclusion

Both CG and Gamma levels may be of utility as a screening tool for earlier diagnosis of antibody deficiency in children and adolescents under 18 yo.