Skip to main content

EDITORIAL article

Front. Hum. Neurosci., 22 October 2024
Sec. Brain-Computer Interfaces
This article is part of the Research Topic Advances in Hybrid and Application-Driven BCI Systems View all 5 articles

Editorial: Advances in hybrid and application-driven BCI systems

  • 1School of Computer Science and Electrical Engineering, Handong Global University, Pohang, Republic of Korea
  • 2Max Planck Institute of Psychiatry, Munich, Germany
  • 3Max Planck Institute for Biological Intelligence, Planegg, Germany
  • 4Carnegie Mellon University, Pittsburgh, PA, United States
  • 5Institute of Neural Engineering, Graz University of Technology, Graz, Austria
  • 6Department of Computer Science, Chemnitz University of Technology, Chemnitz, Germany

This Research Topic features one mini-review and three original research articles that focus on advancements in EEG-based Brain-Computer Interface (BCI) technology. A mini review provides an overview on BCI spelling systems, discussing their underlying paradigms and highlights hybrid spellers. The research articles explore a range of applications, including AttentionCARE, a BCI designed to aid adolescents at high risk for depression; a hybrid BCI system combining eye-tracking and steady-state visual evoked potentials (SSVEP) for controlling a robotic arm in virtual reality; and a method for classifying EEG signals using fewer channels to enhance the performance of motor imagery BCI systems:

The review of Maslova et al. presents the most popular paradigms used as BCI speller systems. There are three main types of BCI-spellers: P300, motor imagery (MI), and steady-state visual evoked potential (SSVEP). While each type has its own limitations, hybrid BCI-spellers combine the strengths of multiple types. They can improve accuracy and reduce the training period required for users to become proficient.

The study by Gall et al. looks at a brain-computer interface called AttentionCARE, which helps adolescents at high risk for depression by using augmented reality and EEG to change how they focus on negative emotions. It mainly targets adolescents with depressed mothers. The results show that AttentionCARE can reliably give feedback on attention to negative emotions, which is important for future treatments. This research helps ensure that such brain-computer interfaces are reliable and can be used in future interventions.

Guo et al. reported a study of hybrid BCI using SSVEP and eye-tracking in virtual reality environment for virtual robotic arm control. Robotic arm control has been previously reported using motor imagination for reaching and grasping tasks and continuous movement and tracking from sensorimotor rhythm, and using motor execution. SSVEP has been also previously used for robotic arm control in a BCI setup. In this study, the authors used a hybrid BCI integrating SSVEP and eye-tracking to further improve the performance. They also tested the system in a virtual reality environment. Results show that with integration of SSVEP and eye-tracking, the number of commends was increased from 4 to 8, as compared to previous work on physical robotic arm control using motor imagination. While further testing in a physical environment is desirable, this work suggests the merits of hybrid BCI through integrating SSVEP and eye-tracking.

Long et al. address the challenge of classifying EEG signals in BCI systems due to high dimensionality from excessive channels. They proposed the Combination of the Euclidean-space Alignment (EA) and Optimized Subband Regularized Common Spatial Pattern to enhance motor imagery BCI systems' performance with fewer channels. Using Dataset1 from BCI Competition IV (2008) with nine subjects and 22 channels, and Dataset2, self-collected from 10 healthy subjects with eight channels, they demonstrated reasonable classification accuracies (the 78.01% accuracy and a kappa coefficient of 0.54 for Dataset1 and 59.77% accuracy and a kappa coefficient of 0.34 for Dataset2), outperforming recent methods despite fewer channels. Therefore, the proposed method is expected to reduce the dependence on the number of channels and samples, simplifying BCI models and enhancing system user-friendliness.

In summary, these studies offer valuable insights into the progression of BCI technology, reviewing BCIs as communication devices, replicability in clinical settings, and improving control systems for robotic devices. The research highlights advancements in hybrid systems and innovative classification methods that enhance both the accuracy and usability of BCI systems, paving the way for more practical and reliable applications in both clinical and real-world environments.

Author contributions

MA: Writing – original draft, Writing – review & editing. BE: Writing – original draft, Writing – review & editing. BH: Writing – original draft, Writing – review & editing. GM-P: Writing – original draft, Writing – review & editing. FR: Writing – original draft, Writing – review & editing.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

The author(s) declared that they were an editorial board member of Frontiers, at the time of submission. This had no impact on the peer review process and the final decision.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Keywords: reproducibility, replicability, brain-computer interfaces, human neuroscience, brain-machine interface

Citation: Ahn M, Edelman BJ, He B, Müller-Putz GR. and Röhrbein F (2024) Editorial: Advances in hybrid and application-driven BCI systems. Front. Hum. Neurosci. 18:1498196. doi: 10.3389/fnhum.2024.1498196

Received: 18 September 2024; Accepted: 07 October 2024;
Published: 22 October 2024.

Edited and reviewed by: Surjo R. Soekadar, Charité University Medicine Berlin, Germany

Copyright © 2024 Ahn, Edelman, He, Müller-Putz and Röhrbein. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Minkyu Ahn, minkyuahn@handong.edu

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.