Holding a Handle for Balance during Continuous Postural Perturbations—Immediate and Transitionary Effects on Whole Body Posture

  • 1Department for Automation, Biocybernetics and Robotics, Jožef Stefan Institute, Ljubljana, Slovenia
  • 2Jožef Stefan International Postgraduate School, Ljubljana, Slovenia
  • 3HRI2 Laboratory, Department of Advanced Robotics, Istituto Italiano di Tecnologia, Genoa, Italy

When balance is exposed to perturbations, hand contacts are often used to assist postural control. We investigated the immediate and the transitionary effects of supportive hand contacts during continuous anteroposterior perturbations of stance by automated waist-pulls. Ten young adults were perturbed for 5 min and required to maintain balance by holding to a stationary, shoulder-high handle and following its removal. Center of pressure (COP) displacement, hip, knee and ankle angles, leg and trunk muscle activity and handle contact forces were acquired. The analysis of results show that COP excursions are significantly smaller when the subjects utilize supportive hand contact and that the displacement of COP is strongly correlated to the perturbation force and significantly larger in the anterior than posterior direction. Regression analysis of hand forces revealed that subjects utilized the hand support significantly more during the posterior than anterior perturbations. Moreover, kinematical analysis showed that utilization of supportive hand contacts alter posture of the whole body and that postural readjustments after the release of the handle, occur at different time scales in the hip, knee and ankle joints. Overall, our findings show that supportive hand contacts are efficiently used for balance control during continuous postural perturbations and that utilization of a handle has significant immediate and transitionary effects on whole body posture.

Introduction

With aging society, falls are becoming an increasingly large problem. A large proportion of falls occur due to the improper weight shifts (Robinovitch et al., 2013) and impaired postural control is a landmark of aging (Maki and McIlroy, 2006; Mansfield and Maki, 2009). When postural control is impaired, handrails, canes and handles are often used to assist maintaining balance by providing additional supportive contacts with the environment. This indicates that holding onto a physical aid is beneficial for postural control.

With respect to the use of hand contacts for postural control, one of the widely investigated phenomena is “light touch” (Jeka, 1997; Krishnamoorthy et al., 2002). These light, fingertip contacts with stationary objects can extend the base of support (Bateni and Maki, 2005) and provide an additional sensory input, which helps individuals to better position them in space (Jeka, 1997). Such sensory information improves postural control in quiet standing by reducing the amplitude of center of pressure (COP) movement (Jeka, 1997; Johannsen et al., 2007; Kouzaki and Masani, 2008; Wing et al., 2011).

On the other hand, in case of perturbed balance reaching arm movements with the aim to grasp for a nearby object is a widely utilized change-in-support strategy (Maki and McIlroy, 2006). Such hand contacts provide mechanical support in addition to the sensory augmentation of the light touch and thus offer a better stabilizing potential in the presence of perturbations (Maki and McIlroy, 1997). Specifically, holding onto a handle increases the base of support of a standing individual and enables a person to generate necessary hand forces to better counteract the perturbations (Babič et al., 2014; Sarraf et al., 2014). A recent study by Babič et al. (2014) showed that the location of the supporting hand contact is important to maximize its stabilizing potential and that the peak forces exerted at the handle during the support surface perturbations are related to the location of the handle.

Aforementioned studies were based on the discrete perturbations of balance which predominantly evoke feedback postural responses. A major component of such responses is comprised of motor actions that are related to various sensorimotor reflexes and to a lesser extent to the feed-forward components of the postural control (Mergner, 2010). Moreover, the discrete perturbations evoke reach-to-grasp arm movements even when the perturbations are so light that they do not physically disturb postural balance (McIlroy and Maki, 1995; Corbeil et al., 2013). In contrast to the discrete perturbations of balance, perturbations that continuously disturb postural balance evoke both feedback and feed-forward components of motor action and in this sense offer a complementary insight into the postural control (Dietz et al., 1993; Schmid et al., 2011).

The remaining question is what is the role of hand contact during continuous perturbations? Therefore, the aim of this article is to study situations where balance of an individual is challenged by continuous postural perturbations and to investigate the role of supportive hand contact in counteracting postural perturbations. Specifically, our goal was to investigate the immediate and the transitionary effects of a supportive hand contact on postural control of an individual whose balance is challenged by continuous anteroposterior perturbations of stance.

Our hypothesis is that a supportive hand contact has a significant influence on postural balance by reducing the COP excursion during the perturbation and that the utilization of the hand contact is more prominent for postural perturbations in the backward direction which are more threatening than the perturbations in the forward direction. Moreover, we hypothesize that utilization of the additional hand support not only alters posture of the human body while the hand is in contact with the environment but also after the release of the handle. To effectively address these hypotheses, we developed an experimental framework where we continuously perturbed postural balance and investigated the relationships between the perturbation force and the COP displacement, kinematical parameters of the human body, and the forces exerted by the supportive hand.

Materials and Methods

Participants

Thirteen healthy right-handed young adults participated in this study after giving their written consent. Data of three subjects were excluded from the analyses due to technical problems during acquisition, therefore we used the data of ten subjects (average age = 22.3 years, SD = 2.2 years, average height 179.2 cm, SD = 5.9 cm and average weight = 76.9 kg, SD = 8.2 kg). The experimental procedures conformed to the latest revision of the Declaration of Helsinki and were approved by the Slovenian National Medical Ethics Committee (No. 112/06/13).

Measurement Protocol

Subjects were asked to step on a force plate, stand straight with the feet placed at hip width and look straight ahead. They were required to keep upright posture and maintain balance without making any unnecessary corrective steps while their balance was continuously perturbed in anteroposterior direction by a motorized waist-pull system (Peternel and Babič, 2013) as depicted in Figure 1. During the experiment, the subjects were not allowed to change their base of support. We marked their individual standing position on the force plate prior to the start of the experiment which was used as a reference for foot position during the experiment. This ensured that the different stance width would not affect subjects’ balance since it has been shown by Bingham and Ting (2013) that active torque at ankle and hip joints scale with stance width. To emulate mild, daily life perturbations such as those during riding on buses, subways and trains (Graaf and van Weperen, 1997) the motorized waist-pull system perturbed the subjects using a band-pass filtered white noise signal (0.25–1.00 Hz) with the maximal perturbation force of 11% of the subjects’ body weight (Figure 2).

FIGURE 1
www.frontiersin.org

Figure 1. Experimental setup. The subject is standing on a force plate, wearing a waist belt connected to the motorized waist-pull system which generated translational force perturbations in the anterior-posterior direction using a band-filtered white noise signal constructed to emulate mild, daily life perturbations.

FIGURE 2
www.frontiersin.org

Figure 2. Perturbation signal sample. Solid black curve represents first 60 s of mean perturbation signal from all 10 subjects with ±1 standard error of the mean (gray shade around the curve). In the first 10 s of each trial the perturbation value was at 0 N—quiet phase. After 10 s (perturbation onset), the perturbation gradually increased with alternated direction and amplitude—perturbation phase. Positive values of mean perturbation force represent forces in anterior direction and negative values represent forces in posterior direction. The perturbation signal was identical in both trials.

The experiment consisted of two consecutive 5 min trials of different standing conditions: balancing while holding to a handle [with-handle (WH)] and without holding to a handle [no-handle (NH)]. First, the subjects were exposed to 5 min of perturbations in the WH trial. In the WH trial, subjects held onto a stationary handle (diameter = 3.2 cm, length = 12 cm) positioned at shoulder height with their right hand. After 5 min the perturbation stopped, subjects released the handle and folded their arms across their chest. Then, on average less than 60 s later, the second trial of 5 min of perturbation started (NH trial). In the NH trial, subjects were standing with their arms folded across their chest. In both trials, subjects were instructed to look straight ahead at all times at a fixed point positioned at the subject’s eyelevel and 3 m in front of the experimental setup. To induce response adaptations (Van Ooteghem et al., 2008; Schmid et al., 2011), the subjects were allowed to familiarize with the experimental procedures prior to the main experimental trials.

Kinetic data were collected using a force plate (9281CA, Kistler Instrumente AG, Winterthur, Switzerland) under the subjects’ feet and a 3-axis force sensor (45E15A, JR3, Woodland, CA, USA) on the handle, both at 1000 samples/s.

Kinematic data were collected at a sampling rate of 100 samples/s using a contactless motion capture system (3D Investigator, Northern Digital Inc., Waterloo, ON, Canada) consisting of a 3 × 3 camera array. Nine active markers were placed at the apparent axis of rotation of the fifth metatarsophalangeal, ankle, knee, hip, shoulder, elbow and wrist joints on the subject’s right side as well as at the base of the platform and the handle.

Anteroposterior displacement of the subject’s COP was derived from the force plate data. In the first 10 s of each trial, the subjects stood quietly (holding a handle with right hand in the first trial, or both arms folded across their chest in the second trial) and no perturbation was applied at the waist (see Figure 2 for reference regarding perturbation signal). The mean COP position from this time period (we refer to this as quiet phase) served as a baseline for calculation of COP excursions in the anterior and posterior direction in the following perturbations (perturbation phase).

Handle forces were calculated by considering the torques of the lever (distance from force sensor to the middle of the subject’s hand on the handle). Kinematic data were low pass filtered (zero lag, 2nd order Butterworth filter with a cut-off frequency 20 Hz). Ankle angle was calculated as the angle between the foot (line connecting the fifth metatarsal and ankle) and the shank (line connecting the ankle and the knee), knee angle as the angle between the shank and thigh (line connecting the knee and the hip), and hip as the angle between the thigh and torso (line connecting the hip and the shoulder). To evaluate the adaptation effects of releasing the handle in the NH trial, an exponential fit of group average joint angles was calculated (Franklin et al., 2003). Adaptation was considered as final once the given joint angle reached the plateau defined by three time constants of the fitted exponential decay function, i.e., once the fitted exponential decay function fell to 5% of its starting value (Honeine et al., 2015; Assländer and Peterka, 2016).

Electromyographical (EMG) electrodes were placed on the right leg (TA, Tibialis Anterior; GA, Gastrocnemius Lateralis; and trunk (MF, Multifidus; OE, Obliques Externus) muscles and their activity was measured using Biometrics DataLOG MW8X at a sampling rate of 1000 samples/s. Preparation of the skin and positioning of the electrodes was performed according to the SENIAM protocol (Hermens et al., 2000). Before the start of the experiment, subjects performed three maximal voluntary contractions (MVC) against resistance of each of the measured muscles. MVC’s were used in EMG post-processing for normalization, to establish a common ground when comparing data between subjects. All EMG signals were band-pass filtered (zero lag, 2nd order Butterworth filter with cut-off frequencies of 20 and 450 Hz), full-wave rectified and low pass filtered (zero lag, 2nd order Butterworth algorithm, 10 Hz cut-off frequency). Finally, EMG signals were normalized with respect to the MVCs and integrated over time (iEMG) to express the magnitude of muscle activity.

We divided COP excursions and contact forces exerted on the handle in two data sets based on their direction—anterior and posterior. For each data set, average values from all 10 subjects were calculated and used in the statistical analysis.

Average hip, knee and ankle angles over the 5 min for each subject were calculated and used for statistical analysis.

Differences between COP displacement in the anterior and posterior directions and subject average joint angles were analyzed using paired samples t-tests. Differences between the WH and NH trials in subject average COP displacements were analyzed for the anterior and posterior directions separately, using a paired samples t-test. The relationship between group average COP excursion and the magnitude of the perturbation and between group average perturbation magnitude and the exerted handle contact force was analyzed using separate linear correlations for anterior and posterior directions. All statistical analyses were performed using SPSS 21 Inc., Chicago, IL, USA at α = 0.05. Effect size (d) was calculated using standard Cohen’s equation (Cohen, 1988).

Results

Supportive Hand Contact has Significant Influence on Postural Balance by Reducing COP Excursion during Perturbation

The diagram in Figure 3 shows the comparison of mean COP excursion between the conditions when the subjects counteracted postural perturbations without using the additional hand contact (NH) and when they did use the handle (WH). Paired samples t-test showed significant effect in reducing the mean COP excursion when the subjects were holding to the handle compared to when they did not hold to the handle. The differences of COP excursion were significantly larger both in the anterior direction (difference of 20.3 mm, t(9) = 7.78, p = 0.001, d = −4.15) and posterior direction (difference of 23.9 mm, t(9) = −11.09, p = 0.001, d = −3.8).

FIGURE 3
www.frontiersin.org

Figure 3. Comparison of center of pressure (COP) excursion between trials when subjects either used additional hand contact or not. Bars represent mean COP excursion during no-handle (NH) and with-handle (WH) trials for the anterior (positive) and posterior (negative) directions. Error bars indicate ±1 standard error of the mean. Statistically significant differences are indicated (*p ≤ 0.02).

Utilization of Hand Contact is more Prominent for Postural Perturbations in Backward Direction than for Perturbations in Forward Direction

In both, NH and WH trials, the COP excursion was larger in the anterior direction (mean ± SE: NH 38.5 ± 1.6 mm, WH 18.2 ± 1.2 mm) compared to the posterior (mean ± SE: NH −34.9 ± 2 mm, WH −11.0 ± 1.5 mm), but this difference was significant only for the WH trial (t(9) = 2.81, p = 0.02, d = 1.52).

We further assessed the effects of utilizing the additional hand contact, and the direction and intensity of perturbation on the maximal COP displacement. The diagrams in Figure 4 show correlations between the perturbation force and the group average COP excursion during NH and WH trials. Additionally, the correlation between the perturbation force and the handle force is shown for the WH trials. The group average COP excursion was strongly correlated with perturbation force in both posterior (rp = 0.77 and rp = 0.67) and anterior (ra = 0.82 and ra = 0.89) directions in the NH and WH trials, respectively (all p < 0.001). Similarly, the forces that subjects applied on the handle was also strongly correlated with the perturbation force (Figure 4C) in both anterior (rp = 0.85, p < 0.001) and posterior directions (ra = 0.81, p < 0.001). Moreover, the slope of the regression line is significantly larger for perturbations in the posterior direction (kp = 1.3), compared to the perturbations in the anterior direction (ka = 0.86).

FIGURE 4
www.frontiersin.org

Figure 4. Correlations between perturbation force and (A) COP excursion in NH trial, (B) COP excursion in WH trial and (C) handle force in the WH trial. Correlations were calculated separately for the anterior (positive) and posterior (negative) direction.

Supportive Hand Contact Affects Whole Body Posture

To investigate how the additional hand contact affects the body posture during the perturbations, we compared the mean values of ankle, knee and hip joint angles between the conditions when the subjects counteracted perturbations without the additional hand contact (NH) and when they did use the handle (WH). The comparison is shown in the diagram in Figure 5.

FIGURE 5
www.frontiersin.org

Figure 5. Comparison of body posture between trials when subjects either used additional hand contact or not. Bars represent mean ankle, knee and hip joint angles during NH and WH trials. Error bars indicate ±1 standard error of the mean. Statistically significant differences are indicated (*p ≤ 0.02).

Multiple paired samples t-tests showed significant effect of the hand contact on all three observed joint angles. Specifically, mean joint angles were significantly lower during the NH trials compared to the WH trials. Differences were the largest in the knee (mean ± SE: 165.1 ± 1.9° for NH, 173.2 ± 1.5° for WH, t(9) = −6.70, p < 0.001, d = 1.4), followed by the hip (mean ± SE: 171.4 ± 2.8° for NH, 181.5 ± 1.6° WH, t(9) = −6.68, p < 0.001, d = 1.1) and the ankle (mean ± SE: 108 ± 1.2° for NH, 112 ± 1.1° WH, t(9) = −5.67, p < 0.001, d = 1.1).

Utilization of Hand Contact has Non-Uniform Transitionary Effect on Whole Body Posture after Release of Handle

To investigate the effect of supportive hand contact on the body posture, an exponential curve was fitted to the group average ankle, knee and hip joint angles calculated during the NH trial that immediately followed the WH trial (Figure 6).

FIGURE 6
www.frontiersin.org

Figure 6. Ankle (A) knee (B) and hip (C) angles over the time course of the perturbation. Thin solid lines represent mean joint angles from all 10 subjects during NH and WH trials. Thick solid lines represent exponential curve fit denoting adaptation of joint angles in the NH (red color) and WH trials (gray color), while shaded areas represent ±1 standard error of the mean of the exponential decay curve. Mean R2 value for the exponential decay curves for ankle joint in the NH trial was mean ± SE: 0.27 ± 0.06, for the knee joint mean ± SE: 0.31 ± 0.08 and for the hip joint mean ± SE: 0.61 ± 0.08. The dotted vertical lines represent perturbation onset while the dashed vertical lines indicate the mean time of stabilized changes in the joint angles after perturbation onset.

Exponential fits revealed that postural readjustments after the release of the handle did not occur simultaneously throughout the body. Instead, the readjustments occurred at different time scales in the hip, knee and ankle joints. Specifically, joint angles stabilized first in the ankle (mean ± SE: 133 ± 103.5 s after perturbation onset), followed by the hip (mean ± SE: 188 ± 90.8 s after the perturbation onset) and finally in the knee (mean ± SE: 195 ± 92.5 s after the perturbation onset). However, a paired-samples t-test did not show statistically significant difference between any of the compared pairs due to the high variability of data.

Analysis of Muscle Activity

Muscle activity was significantly lower during the WH trial than during the NH condition both for the leg muscles (GA t(9) = 3.57, p = 0.04, d = −0.89; TA t(9) = 6.41, p = 0.002, d = −23 1.85) and one of the trunk muscles (MF t(9) = 6.5, p = 0.001, d = −1.01), as can be seen in Figure 7. Leg muscle activity was 18.4 ± 4.9% lower in the GA (mean ± SE: NH: 28.9 ± 6.5% MVC, WH: 10.6 ± 2.3% MVC) and for 23.7 ± 3.5% in the TA (mean ± SE: NH: 27.2 ± 4% MVC, WH: 3.47 ± 1.88% MVC), while the trunk muscle activity was 14.3 ± 2.1% lower in the MF (mean ± SE: NH: 36.2 ± 4.5% MVC, WH: 21.8 ± 3.7% MVC), but no significant change was observed in the OE (mean ± SE: NH: 10.4 ± 7.4% MVC, WH: 8.97 ± 4.63% MVC).

FIGURE 7
www.frontiersin.org

Figure 7. Comparison of integrated Electromyographical (EMG) between trials when subjects either used additional hand contact or not. Bars represent iEMG of four muscles (GA, Gastrocnemius Lateralis; TA, Tibialis Anterior; OE, Obliques Externus; MF, Multifidus) during NH and WH trials. Error bars indicate ±1 standard error of the mean. Statistically significant differences are indicated (*p ≤ 0.02).

Discussion

We investigated how subjects used an additional hand support (handle) to maintain upright posture when exposed to mild and continuous perturbations elicited by waist-pull apparatus in the anteroposterior directions. The use of handle reduced the destabilizing effect of the applied perturbation by reducing the excursions of COP. These results are in line with previous studies that investigated light-touch contacts. Those studies found a reduction of COP excursions during bipedal stance with (Johannsen et al., 2007; Hausbeck et al., 2009) and without externally applied perturbations (Jeka, 1997; Krishnamoorthy et al., 2002; Kouzaki and Masani, 2008). However, in our case the handle compensated for a significant load and served more than just a light-touch contact. The mean force in the handle was over 24 N (mean ± SE: 24.5 ± 7.9 N) where in other light-touch studies, contact forces usually did not exceed 3 N (Krishnamoorthy et al., 2002; Johannsen et al., 2007; Kouzaki and Masani, 2008). Comparison between measured mean handle force and mean perturbation force, which was ~20 N (mean ± SE: 19.5 ± 1.7 N), indicates that a significant portion of perturbation on postural stability was counterbalanced by the hand.

COP excursions were strongly correlated with the perturbation force in both directions, indicating the perturbations were effective, albeit mild. When holding a handle, the excursions of the COP were larger in the anterior than in posterior direction and less correlated with the perturbation force. Due to the specifics of our design, i.e., the use of a continuous perturbation, it was impossible to investigate pure feedback postural responses to the specific direction of the perturbation. However, asymmetry in COP excursion might to be due to a differential use of the handle, indicated by a steeper slope of the regression line between the perturbation force and the forces exerted on the handle for the posterior direction. This indicates that subjects have utilized the handle more when they counteracted the posterior COP excursions. This may be related to a more threatening situation due to the inability of the subjects to see (look) behind them, as the directions to the subjects were to look straight ahead at all times, and due to smaller stability margin in the posterior direction (Pai and Patton, 1997; Hof et al., 2005). This finding is in line with our previous study using a similar handle location and discrete perturbations caused by support platform translations, in which COP excursions were larger in the anterior direction (Babič et al., 2014).

Using a handle for balance support was beneficial, since it resulted in less displacement of COP and a smaller deviation from the neutral posture, as evident by the average joint angles. Measured joint angles in WH condition stayed closer to the neutral anatomic position than joint angles in the NH condition. Additionally, leg and trunk muscle activity was also significantly lower during the WH trial compared to the NH trial. This is consistent with the decreased leg muscle activity reported previously, when subjects had to hold (Cordo and Nashner, 1982) or touch (Sozzi et al., 2012) a surrounding object. Unlike other muscles, we found no decrease of muscle activity in the OE, which controls the rotation of the torso (Ng et al., 2001). The unilateral hand support might have caused a rotation of the trunk, which the subjects had to counteract by the OE activity. Prior to experiments we instructed subjects to use the handle in any way they prefer. Overall reduced muscle activity in legs and trunk and increased activity in arm muscles in case of using handle indicate that a portion of significant perturbation load was shifted from legs/trunk to arms. The same can be confirmed by high measured handle forces and lesser COP excursions in case of WH trial. The use of hand contact to compensate a significant portion of perturbation, even though it could be counteracted solely by legs/trunk, might be preferred since legs in a stance already have to compensate the load of the body mass (Bateni and Maki, 2005; Mergner, 2010).

Finally, when subjects had to release the handle for balance control they prepared for the more difficult NH condition even before the perturbation onset, as evident from differences in the starting joint angles. When the perturbation began this preparation was even more pronounced and joint angles changed further. These postural readjustments appear to occur at different time scales in the hip, knee and ankle joints, however that was not statistically confirmed. The subjects bended their ankle, knee and hip joints which resulted in a more flexed leg and lower hip position. Hip position can serve as an indication of the COM position and lowering of the COM could facilitate balance control (Rosker et al., 2011). Hence, these changes indicate feed-forward preparation to ease control of balance when expecting more challenging conditions, i.e., in the absence of handle. Along the same line, anticipation of the upcoming perturbations was also reported to cause changes in kinematics during quiet stance (Santos et al., 2010), walking (Pijnappels et al., 2001), recovery stepping (Pater et al., 2015) and tripping (Potocanac et al., 2014).

Author Contributions

JC, LP and JB designed the study. JC and LP performed the experiments. JC, LP, ZP and JB analyzed the data and wrote the manuscript.

Funding

The work presented in this article was supported by the European Community Framework Programme 7 through the CoDyCo project, contract no. 600716.

Conflict of Interest Statement

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

Assländer, L., and Peterka, R. J. (2016). Sensory reweighting dynamics following removal and addition of visual and proprioceptive cues. J. Neurophysiol. 116, 272–285. doi: 10.1152/jn.01145.2015

PubMed Abstract | CrossRef Full Text | Google Scholar

Babič, J., Petrič, T., Peternel, L., and Šarabon, N. (2014). Effects of supportive hand contact on reactive postural control during support perturbations. Gait Posture 40, 441–446. doi: 10.1016/j.gaitpost.2014.05.012

PubMed Abstract | CrossRef Full Text | Google Scholar

Bateni, H., and Maki, B. E. (2005). Assistive devices for balance and mobility: benefits, demands and adverse consequences. Arch. Phys. Med. Rehabil. 86, 134–145. doi: 10.1016/j.apmr.2004.04.023

PubMed Abstract | CrossRef Full Text | Google Scholar

Bingham, J. T., and Ting, L. H. (2013). Stability radius as a method for comparing the dynamics of neuromechanical systems. IEEE Trans. Neural Syst. Rehabil. Eng. 21, 840–848. doi: 10.1109/TNSRE.2013.2264920

PubMed Abstract | CrossRef Full Text | Google Scholar

Cohen, J. (1988). Statistical Power Analysis for the Behavioral Sciences. 2nd Edn. Mahwah, NJ: Lawrence Erlbaum Associates.

Corbeil, P., Bloem, B. R., van Meel, M., and Maki, B. E. (2013). Arm reactions evoked by the initial exposure to a small balance perturbation: a pilot study. Gait Posture 37, 300–303. doi: 10.1016/j.gaitpost.2012.07.017

PubMed Abstract | CrossRef Full Text | Google Scholar

Cordo, P. J., and Nashner, L. M. (1982). Properties of postural adjustments associated with rapid arm movements. J. Neurophysiol. 47, 287–302.

PubMed Abstract | Google Scholar

Dietz, V., Trippel, M., Ibrahim, I. K., and Berger, W. (1993). Human stance on a sinusoidally translating platform: balance control by feedforward and feedback mechanisms. Exp. Brain Res. 93, 352–362. doi: 10.1007/bf00228405

PubMed Abstract | CrossRef Full Text | Google Scholar

Franklin, D. W., Osu, R., Burdet, E., Kawato, M., and Milner, T. E. (2003). Adaptation to stable and unstable dynamics achieved by combined impedance control and inverse dynamics model. J. Neurophysiol. 90, 3270–3282. doi: 10.1152/jn.01112.2002

PubMed Abstract | CrossRef Full Text | Google Scholar

Graaf, B. D., and van Weperen, W. (1997). The retention of balance: an exploratory study into the limits of acceleration the human body can withstand without losing equilibrium. Hum. Factors 39, 111–118. doi: 10.1518/001872097778940614

PubMed Abstract | CrossRef Full Text | Google Scholar

Hausbeck, C. J., Strong, M. J., Tamkei, L. S., Leonard, W. A., and Ustinova, K. I. (2009). The effect of additional hand contact on postural stability perturbed by a moving environment. Gait Posture 29, 509–513. doi: 10.1016/j.gaitpost.2008.11.014

PubMed Abstract | CrossRef Full Text | Google Scholar

Hermens, H. J., Freriks, B., Disselhorst-Klug, C., and Rau, G. (2000). Development of recommendations for SEMG sensors and sensor placement procedures. J. Electromyogr. Kinesiol. 10, 361–374. doi: 10.1016/s1050-6411(00)00027-4

PubMed Abstract | CrossRef Full Text | Google Scholar

Hof, A. L., Gazendam, M. G. J., and Sinke, W. E. (2005). The condition for dynamic stability. J. Biomech. 38, 1–8. doi: 10.1016/j.jbiomech.2004.03.025

PubMed Abstract | CrossRef Full Text | Google Scholar

Honeine, J.-L., Crisafulli, O., Sozzi, S., and Schieppati, M. (2015). Processing time of addition or withdrawal of single or combined balance-stabilizing haptic and visual information. J. Neurophysiol. 114, 3097–3110. doi: 10.1152/jn.00618.2015

PubMed Abstract | CrossRef Full Text | Google Scholar

Jeka, J. J. (1997). Light touch contact as a balance aid. Phys. Ther. 77, 476–487.

PubMed Abstract | Google Scholar

Johannsen, L., Wing, A. M., and Hatzitaki, V. (2007). Effects of maintaining touch contact on predictive and reactive balance. J. Neurophysiol. 97, 2686–2695. doi: 10.1152/jn.00038.2007

PubMed Abstract | CrossRef Full Text | Google Scholar

Kouzaki, M., and Masani, K. (2008). Reduced postural sway during quiet standing by light touch is due to finger tactile feedback but not mechanical support. Exp. Brain Res. 188, 153–158. doi: 10.1007/s00221-008-1426-5

PubMed Abstract | CrossRef Full Text | Google Scholar

Krishnamoorthy, V., Slijper, H., and Latash, M. L. (2002). Effects of different types of light touch on postural sway. Exp. Brain Res. 147, 71–79. doi: 10.1007/s00221-002-1206-6

PubMed Abstract | CrossRef Full Text | Google Scholar

Maki, B. E., and McIlroy, W. E. (1997). The role of limb movements in maintaining upright stance: the “change-in-support” strategy. Phys. Ther. 77, 488–507.

PubMed Abstract | Google Scholar

Maki, B. E., and McIlroy, W. E. (2006). Control of rapid limb movements for balance recovery: age-related changes and implications for fall prevention. Age Ageing 35, ii12–ii18. doi: 10.1093/ageing/afl078

PubMed Abstract | CrossRef Full Text | Google Scholar

Mansfield, A., and Maki, B. E. (2009). Are age-related impairments in change-in-support balance reactions dependent on the method of balance perturbation? J. Biomech. 42, 1023–1031. doi: 10.1016/j.jbiomech.2009.02.007

PubMed Abstract | CrossRef Full Text | Google Scholar

McIlroy, W. E., and Maki, B. E. (1995). Early activation of arm muscles follows external perturbation of upright stance. Neurosci. Lett. 184, 177–180. doi: 10.1016/0304-3940(94)11200-3

PubMed Abstract | CrossRef Full Text | Google Scholar

Mergner, T. (2010). A neurological view on reactive human stance control. Annu. Rev. Control 34, 177–198. doi: 10.1016/j.arcontrol.2010.08.001

CrossRef Full Text | Google Scholar

Ng, J. K.-F., Parnianpour, M., Richardson, C. A., and Kippers, V. (2001). Functional roles of abdominal and back muscles during isometric axial rotation of the trunk. J. Orthop. Res. 19, 463–471. doi: 10.1016/s0736-0266(00)90027-5

PubMed Abstract | CrossRef Full Text | Google Scholar

Pai, Y. C., and Patton, J. (1997). Center of mass velocity-position predictions for balance control. J. Biomech. 30, 347–354. doi: 10.1016/s0021-9290(96)00165-0

PubMed Abstract | CrossRef Full Text | Google Scholar

Pater, M. L., Rosenblatt, N. J., and Grabiner, M. D. (2015). Expectation of an upcoming large postural perturbation influences the recovery stepping response and outcome. Gait Posture 41, 335–337. doi: 10.1016/j.gaitpost.2014.10.026

PubMed Abstract | CrossRef Full Text | Google Scholar

Peternel, L., and Babič, J. (2013). Learning of compliant human-robot interaction using full-body haptic interface. Adv. Robot. 27, 1003–1012. doi: 10.1080/01691864.2013.808305

CrossRef Full Text | Google Scholar

Pijnappels, M., Bobbert, M. F., and van Dieën, J. H. (2001). Changes in walking pattern caused by the possibility of a tripping reaction. Gait Posture 14, 11–18. doi: 10.1016/s0966-6362(01)00110-2

PubMed Abstract | CrossRef Full Text | Google Scholar

Potocanac, Z., de Bruin, J., van der Veen, S., Verschueren, S., van Dieën, J., Duysens, J., et al. (2014). Fast online corrections of tripping responses. Exp. Brain Res. 232, 3579–3590. doi: 10.1007/s00221-014-4038-2

PubMed Abstract | CrossRef Full Text | Google Scholar

Robinovitch, S. N., Feldman, F., Yang, Y., Schonnop, R., Leung, P. M., Sarraf, T., et al. (2013). Video capture of the circumstances of falls in elderly people residing in long-term care: an observational study. Lancet 381, 47–54. doi: 10.1016/S0140-6736(12)61263-X

PubMed Abstract | CrossRef Full Text | Google Scholar

Rosker, J., Markovic, G., and Sarabon, N. (2011). Effects of vertical center of mass redistribution on body sway parameters during quiet standing. Gait Posture 33, 452–456. doi: 10.1016/j.gaitpost.2010.12.023

PubMed Abstract | CrossRef Full Text | Google Scholar

Santos, M. J., Kanekar, N., and Aruin, A. S. (2010). The role of anticipatory postural adjustments in compensatory control of posture: 2. Biomechanical analysis. J. Electromyogr. Kinesiol. 20, 398–405. doi: 10.1016/j.jelekin.2010.01.002

PubMed Abstract | CrossRef Full Text | Google Scholar

Sarraf, T. A., Marigold, D. S., and Robinovitch, S. N. (2014). Maintaining standing balance by handrail grasping. Gait Posture 39, 258–264. doi: 10.1016/j.gaitpost.2013.07.117

PubMed Abstract | CrossRef Full Text | Google Scholar

Schmid, M., Bottaro, A., Sozzi, S., and Schieppati, M. (2011). Adaptation to continuous perturbation of balance: progressive reduction of postural muscle activity with invariant or increasing oscillations of the center of mass depending on perturbation frequency and vision conditions. Hum. Mov. Sci. 30, 262–278. doi: 10.1016/j.humov.2011.02.002

PubMed Abstract | CrossRef Full Text | Google Scholar

Sozzi, S., Do, M. C., Monti, A., and Schieppati, M. (2012). Sensorimotor integration during stance: processing time of active or passive addition or withdrawal of visual or haptic information. Neuroscience 212, 59–76. doi: 10.1016/j.neuroscience.2012.03.044

PubMed Abstract | CrossRef Full Text | Google Scholar

Van Ooteghem, K., Frank, J. S., Allard, F., Buchanan, J. J., Oates, A. R., and Horak, F. B. (2008). Compensatory postural adaptations during continuous, variable amplitude perturbations reveal generalized rather than sequence-specific learning. Exp. Brain Res. 187, 603–611. doi: 10.1007/s00221-008-1329-5

PubMed Abstract | CrossRef Full Text | Google Scholar

Wing, A. M., Johannsen, L., and Endo, S. (2011). Light touch for balance: influence of a time-varying external driving signal. Philos. Trans. R. Soc. Lond. B Biol. Sci. 366, 3133–3141. doi: 10.1098/rstb.2011.0169

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: falls, handle, grasping, postural balance, balance recovery

Citation: Čamernik J, Potocanac Z, Peternel L and Babič J (2016) Holding a Handle for Balance during Continuous Postural Perturbations—Immediate and Transitionary Effects on Whole Body Posture. Front. Hum. Neurosci. 10:486. doi: 10.3389/fnhum.2016.00486

Received: 08 June 2016; Accepted: 13 September 2016;
Published: 26 September 2016.

Edited by:

Eric Yiou, University of Paris-Sud, France

Reviewed by:

Jean-Louis Honeine, University of Pavia, Italy
Teddy Caderby, University of La Réunion, France

Copyright © 2016 Čamernik, Potocanac, Peternel and Babič. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution and reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Jan Babič, amFuLmJhYmljJiN4MDAwNDA7aWpzLnNp

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.