Skip to main content

ORIGINAL RESEARCH article

Front. Endocrinol., 11 October 2022
Sec. Obesity
This article is part of the Research Topic Endocrine and Metabolic Consequences of Childhood Obesity, Volume II View all 21 articles

Body mass index, basal insulin and glycemic control in children with type 1 diabetes treated with the advanced hybrid closed loop system remain stable - 1-year prospective, observational, two-center study

Sebastian SegetSebastian Seget1Przemys&#x;awa Jarosz-ChobotPrzemysława Jarosz-Chobot1Agnieszka OchabAgnieszka Ochab2Joanna PolanskaJoanna Polanska3Ewa RusakEwa Rusak1Paulina WitoszekPaulina Witoszek4Agata Chobot*Agata Chobot2*
  • 1Department of Children’s Diabetology, Medical University of Silesia, Katowice, Poland
  • 2Department of Pediatrics, Institute of Medical Sciences, University of Opole, Opole, Poland
  • 3Department of Data Science and Engineering, Silesian University of Technology, Gliwice, Poland
  • 4Department of Children’s Diabetology and Pediatrics, John Paul II Upper Silesian Child Health Centre, Katowice, Poland

Background: Information on the influence of insulin treatment using advanced hybrid closed loop systems (AHCL) on body weight of young patients with type 1 diabetes (T1D) is scarce. The aim of this study was to observe whether there were any changes in body mass index (BMI) of children and adolescents with T1D treated using the Medtronic Minimed 780G AHCL after 1 year of follow up and to analyze potential associations between these changes and the insulin doses.

Materials and methods: For 50 children and adolescents (age 5.4-16.8 years, 24 (48%) boys, T1D for 3.9 ± 2.56 years) using an AHCL system anthropometric and AHCL data were collected prospectively. BMI Z-scores and two-week AHCL records obtained after AHCL enrollment were compared with data after 6 months and also 1 year after starting AHCL.

Results: The BMI Z-score of the patients at 1 year follow-up did not change from time of AHCL initiation (0.51 ± 2.79 vs 0.57 ± 2.85, p>0.05). There was a slight increase in total daily insulin per kg of body weight (0.67 ± 0.21 U/kg vs 0.80 ± 0.21 U/kg, p <0.001), but the percent of basal insulin was unchanged (34.88 ± 6.91% vs 35.08 ± 6.30%, p>0.05). We observed also no change (AHCL start vs after 1 year) in glycemic control parameters: average sensor glucose (131.36± 11.04 mg/dL vs 132.45 ± 13.42 mg/dL, p>0.05), coefficient of variation (34.99± 5.17% vs 34.06 ± 5.38%, p>0.05), glucose management indicator (6.45 ± 0.26% vs 6.48 ± 0.32%, p>0.05), and time spent in the range of 70–180 mg/dL (79.28 ± 8.12% vs 80.40 ± 8.25%, p>0.05).

Conclusion: During the 1 year of follow-up the BMI of children and adolescents with T1D treated with an AHCL system remained stable. Although there was a slight increase in the total daily insulin dose, the percent of basal insulin was unchanged. The patients maintained recommended glycemic control.

Introduction

The prevalence of overweight and obesity among youth with type 1 diabetes (T1D) is steadily increasing and reached even 35% in recent reports (14). Excessive body weight complicates attainment of recommended glucose control targets and is often tied with use of higher daily and basal insulin doses (5, 6). Obesity is also an independent, additional risk factor of macro- and microvascular complications, non-alcoholic fatty liver disease and polycystic ovary syndrome in individuals with T1D (713). Moreover youth with T1D and obesity are at higher risk of developing peripheral and cardiac autonomic neuropathy (1416).

Evidence from the Diabetes Control and Complications Trial suggested that using high doses of insulin was related to weight gain in patients with diabetes (17). Although a later 10-year observation did not reach an identical conclusion (18) it seems that the relation between insulin treatment and excessive body weight or weight gain has not been fully explained (4, 8, 1922).

Worth emphasizing is that children with T1D and obesity face many difficulties when attempting to treat both conditions. For example dieting and exercise, well known methods to decrease body weight, require additional education, selfcare and awareness due to the risk of hypoglycaemia (8, 2325).

New technologies in the treatment of T1D, including the advanced hybrid closed loop (AHCL) system may perhaps be a good tool to make weight maintenance easier for children and adolescents with T1D (26). On the other hand these new technologies bring more flexibility in daily consumption. Knowing the action of insulin and that the mainstay of treatment for obesity are diet and exercise, one of the necessary approaches is developing treatment strategies with lowest possible daily insulin dose that would at the same not impair the glycemic control (8, 24, 25, 27).

Because of the increasing problem of overweight and obesity among children and adolescents with T1D it seems vital to further investigate this topic and increase the knowledge on how to prevent or treat excessive body weight in these patients. A recent meta-analysis showed no differences in weight gain in children treated with either insulin pumps or multiple daily injections (28, 29). However another study, that analyzed weight in children who switched from MDI to insulin pump, demonstrated different trends in weight gain. The results indicated a positive association between the basal insulin dose and rate of weight gain, while there was no association with the total daily insulin dose (30). Insulin pump treatment using recommended settings might help in reducing the basal insulin dose (31).

Considering the above aspects, our study aimed to observe if there were changes in weight of children and adolescents with T1D using an AHCL system after 1 year of follow up and to analyze potential associations with the daily and basal insulin doses.

Materials and methods

Patients

We enrolled for the study and followed prospectively 50 children and adolescents with T1D, treated with the AHCL system MiniMed 780G in automatic mode, at two regional pediatric diabetes centers (Department of Children’s Diabetology, University Clinical Hospital of the Medical University of Silesia in Katowice and Department of Pediatrics, University Clinical Hospital of the University of Opole, Poland), both Centers of Reference of the SWEET (Better control in Pediatric and Adolescent diabeteS: Working to crEate CEnTers of Reference) network. Diabetes care for children in Poland is centralized and carried out in regional centers belonging mostly to academic institutions. Inclusion criteria for the study were: age ≦̸ 18 years, as well as more than 70% of the sensor usage time, and more than 70% spent in automatic mode - to obtain reliable continuous glucose monitoring (CGM) and AHCL data.

Methods

The study group was characterized by biometric parameters - age, sex, duration of T1D. Data from the AHCL system was automatically sent to the CareLink server and retrieved using CareLink Professional software (Medtronic MiniMed, USA). Two-week AHCL records as well as anthropometric parameters - body mass and height - were collected prospectively: right after AHCL enrollment, 6 months, and 1 year after starting AHCL. For each time point the body mass index (BMI) z-score was calculated using the individual’s weight and height and the World Health Organization (WHO) reference values (32). CGM readings were analyzed using GlyCulator 3.0 software (Medical University of Łódz, Poland) (33).

Statistical analysis

The statistical analyses were performed using the Statistica 13.3 software (StatSoft, Inc., Tulsa, OK, USA). Descriptive statistics (mean, standard deviation, median, interquartile range, minimum and maximum values, coefficient of variation, and their 95% confidence intervals were calculated for each parameter. Data distribution was tested using the Shapiro–Wilk test. The differences between baseline and at 6 months follow-up as well as between baseline and at 1 year follow-up, were established, using Student’s t-test for dependent samples or the Wilcoxon signed rank test, whichever was appropriate according to the data distribution. Results were considered significant at p value lower than 0.05.

The study protocol was approved by the Local Bioethics Committee of the Medical University of Silesia in Katowice (Decision no. PCN/0022/KBI/83/2 of March 30, 2021).

Results

The study included 50 children and adolescents with an average age of 9.9 ± 2.4 years (median: 9.7, range: 5.4-16.8), 24 (48%) of them were male. The average onset of T1D was 6.0 ± 2.9 (median: 5.7, range: 0.8-13.0) years and mean T1D duration was 3.9 ± 2.6 years (median: 3.63, range: 0.3-10.7).

BMI z-scores of the studied children and adolescents did not change significantly neither after 6 nor after 12 months of follow-up (Table 1 and Figure 1). There was a slight increase in total daily insulin (TDI) dose from baseline (by 0.1 U/kg at 6 months and by 0.13 U/kg after 1 year of follow-up, p<0.001), however the percent of basal and bolus insulin remained stable. The amount of insulin in auto-corrective boluses increased significantly at 6 and 12 months (respectively by 0.82 U and 1.24 U, p<0.05) (Table 1 and Figure 1).

FIGURE 1
www.frontiersin.org

Figure 1 Body mass index, daily insulin doses, basal percentage and TIR of children and adolescents with type 1 diabetes using the advanced hybrid closed-loop system at initiation of the system, at 6 months and 1 year of follow-up.

TABLE 1
www.frontiersin.org

Table 1 Body mass index, daily insulin doses and sensor data of children and adolescents with type 1 diabetes using the advanced hybrid closed-loop system at initiation of the system, at 6 months and 1 year of follow-up.

In general we did not observe changes after 6 or after 12 months of follow-up in glycemic control parameters: average sensor glucose, coefficient of variation, glucose management indicator, and percent of sensor glucose values in different ranges. Only the percent of time spent in range 54-70 mg/dl and <54 mg/dl was significantly reduced after 6 months (p<0.05), but did not differ from baseline after one year of treatment (Table 1). After one year, the use of the AHCL auto mode (% of time using Smartguard) increased significantly (p<0.05), while maintaining similar time of sensor use (Table 1).

Discussion

We describe stable BMI z-scores of children and adolescents with T1D using the AHCL system during a 1-year follow up which is the first such long observation (34--45). Similar results, also for a pediatric cohort of individuals with T1D, were obtained by Tornese et al., who reported no change in BMI z-score after 6 months of insulin treatment using either the hybrid closed-loop (Minimed 670G) or AHCL (Minimed 780G) systems. Noteworthy, our patients were characterized by more optimal glycemic control (lower GMI 6.48% vs 7.1% and higher TIR 81.16% vs 72%) after 6 months of AHCL use with a similar time spent in auto-mode (96.62% vs 96) and percent of sensor use (94.04% vs 92%) (36). Among the growing number of studies evaluating the AHCL Minimed 780G system these are to our knowledge the only two investigating the associations with BMI z-score (3445). Former studies that observed BMI in children with T1D using insulin pumps other than AHCL showed not unequivocal results although the latest metaanalysis suggested no change in body mass (28, 29).

Weight gain was linked to the basal insulin dose and seemed to be independent from the TDI dose (30). Our observations from this study stay in line with the previous findings - no change in BMI z-score was accompanied by a slight increase in TDI. The percentage of basal insulin was 34.88% and did not change after 6 or 12 months of AHCL use. Also the largest pediatric AHCL study during which 790 patients 15 years of age were followed for 6 months (time in auto mode at 6 months 94.9%) revealed an increase in TDI (44). In two other investigations the transition from sensor augmented pump with low glucose suspend system (SAP-LGS) or predictive low glucose suspend system (SAP-PLGS) to AHCL - contrary to our findings - was associated with a decrease in basal insulin with a simultaneous increase in bolus insulin, which is most likely due to self-correction (39, 45). This small but significant increase of TDI in our cohort may be partially explained by the fact that the studied population was younger and some of these children might have entered puberty during the observation time.

Another interesting observation from this study is the increased use of the AHCL auto mode and no change of time of sensor use after one year of observation. The high and unchanged sensor use that was found also in another study may result from the necessity to use it to operate the Minimed system in automatic mode (36). The increasing time in auto-mode is optimistic and would suggest that the patients are not only keen to use it as a novelty but with time learn to rely on it and use it more.

The studied cohort showed a high TIR and other sensor parameters very well fitting the recommendations. This optimal control was maintained during the 1 year of follow-up. Authors of shorter, up to 6 months, observations described significant improvements in glycemic control parameters after switching to AHCL from SAP-LGS/PLGS. However the cohort presented in this study as well as the subgroup of patients from Poland that were included in the publication by Arrieta et al. had the best baseline glycemic control (44).

The above discussed aspects suggest that the AHCL may help to sustain good glycemic control without a risk of increasing body weight. The unchanged percent of time <70 and <54 mg/dl can be also interpreted as no increase in severe hypoglycaemia risk. If AHCL could be a beneficial tool for overweight or obese children with T1D in terms facilitaing weight reduction without impairment in glycemic control requires further studies.

The novelty of this study is the longest, 1 year follow-up of the AHCL use in auto-mode in the pediatric population combined with the assessment of BMI z-score changes. Another strength of this investigation is the youngest observed until now (mean age: 9.88 ± 2.44) (3445) cohort characterized by good glycemic control parameters. Nevertheless we acknowledge the limitations, which include the lack of the assessment of the amount of carbohydrates consumed as well as no detailed dietary evaluation at baseline and follow up that would allow us to note any changes in eating behaviors.

Conclusion

During the 1 year of follow-up the BMI z-score of children and adolescents with T1D using an AHCL system remained stable. Although there was a slight increase in the total daily insulin dose, the percent of basal insulin was unchanged. The patients maintained recommended glycemic control.

Data availability statement

The datasets generated and analyzed for this study are available from the corresponding or first author upon reasonable request.

Ethics statement

The studies involving human participants were reviewed and approved by Local Bioethics Committee of the Medical University of Silesia in Katowice (Decision no. PCN/0022/KBI/83/2 of March 30, 2021). Written informed consent to participate in this study was provided by the participants’ legal guardian/next of kin.

Author contributions

SS researched data, performed statistical analysis, participated in data interpretation and drafting the manuscript. PJ-C designed the study and reviewed and edited the manuscript. AO, ER, and PW participated in researching data and contributed to the drafting of the manuscript. JP supervised the statistical analysis and participated in data interpretation. AC reviewed the study design, participated in data interpretation, reviewed and edited the manuscript. All authors approved the final version of the manuscript. AC and SS are the guarantors of this work and, as such, had full access to all the data in the study and take responsibility for the integrity of the data and the accuracy of the data analysis.

Funding

JP was financed by SUT grant no 02/070/BK_22/0033 project.

Conflict of interest

P-JC has received speaker honoraria from Medtronic, DexCom, Abbott, Ypsomed, and Roche, was a member of the advisory boards for Medtronic and Abbott and received research support from Medtronic. SS has received speaker honoraria from Medtronic and Ypsomed.

The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Ciężki S, Kurpiewska E, Bossowski A, Głowińska-Olszewska B. Multi-faceted influence of obesity on type 1 diabetes in children - from disease pathogenesis to complications. Front Endocrinol (Lausanne) (2022) 16:890833(13). doi: 10.3389/fendo.2022.890833

CrossRef Full Text | Google Scholar

2. Liu LL, Lawrence JM, Davis C, Liese AD, Pettitt DJ, Pihoker C, et al. SEARCH for diabetes in youth study group. Prevalence of overweight and obesity in youth with diabetes in USA: The SEARCH for diabetes in youth study. Pediatr Diabetes (2010) 11(1):4–11. doi: 10.1111/j.1399-5448.2009.00519.x

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Maffeis C, Birkebaek NH, Konstantinova M, Schwandt A, Vazeou A, Casteels K, et al. SWEET study group. Prevalence of underweight, overweight, and obesity in children and adolescents with type 1 diabetes: Data from the international SWEET registry. Pediatr Diabetes (2018) 19(7):1211–20. doi: 10.1111/pedi.12730

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Baskaran C, Volkening LK, Diaz M, Laffel LM. A decade of temporal trends in overweight/obesity in youth with type 1 diabetes after the diabetes control and complications trial. Pediatr Diabetes (2015) 16(4):263–70. doi: 10.1111/pedi.12166

PubMed Abstract | CrossRef Full Text | Google Scholar

5. DuBose SN, Hermann JM, Tamborlane WV, Beck RW, Dost A, DiMeglio LA, et al. Type 1 diabetes exchange clinic network and diabetes prospective follow-up registry. obesity in youth with type 1 diabetes in Germany, Austria, and the united states. J Pediatr (2015) 167(3):627–32.e1-4. doi: 10.1016/j.jpeds.2015.05.046

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Muis MJ, Bots ML, Bilo HJ, Hoogma RP, Hoekstra JB, Grobbee DE, et al. Determinants of daily insulin use in type 1 diabetes. J Diabetes Complications (2006) 20(6):356–60. doi: 10.1016/j.jdiacomp.2005.08.006

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Corbin KD, Driscoll KA, Pratley RE, Smith SR, Maahs DM, Mayer-Davis EJ. Advancing care for type 1 diabetes and obesity network (ACT1ON). obesity in type 1 diabetes: Pathophysiology, clinical impact, and mechanisms. Endocr Rev (2018) 1;39(5):629–63. doi: 10.1210/er.2017-00191

CrossRef Full Text | Google Scholar

8. Van der Schueren B, Ellis D, Faradji RN, Al-Ozairi E, Rosen J, Mathieu C. Obesity in people living with type 1 diabetes. Lancet Diabetes Endocrinol (2021) 9(11):776–85. doi: 10.1016/S2213-8587(21)00246-1

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Polsky S, Ellis SL. Obesity, insulin resistance, and type 1 diabetes mellitus. Curr Opin Endocrinol Diabetes Obes (2015) 22(4):277–82. doi: 10.1097/MED.0000000000000170

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Purnell JQ, Zinman B, Brunzell JD, DCCT/EDIC Research Group. The effect of excess weight gain with intensive diabetes mellitus treatment on cardiovascular disease risk factors and atherosclerosis in type 1 diabetes mellitus: Results from the diabetes control and complications Trial/Epidemiology of diabetes interventions and complications study (DCCT/EDIC) study. Circulation (2013) 127(2):180–7. doi: 10.1161/CIRCULATIONAHA.111.077487

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Pinhas-Hamiel O, Levek-Motola N, Kaidar K, Boyko V, Tisch E, Mazor-Aronovitch K, et al. Prevalence of overweight, obesity and metabolic syndrome components in children, adolescents and young adults with type 1 diabetes mellitus. Diabetes Metab Res Rev (2015) 31(1):76–84. doi: 10.1002/dmrr.2565

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Chillarón JJ, Goday A, Flores-Le-Roux JA, Benaiges D, Carrera MJ, Puig J, et al. Estimated glucose disposal rate in assessment of the metabolic syndrome and microvascular complications in patients with type 1 diabetes. J Clin Endocrinol Metab (2009) 94(9):3530–4. doi: 10.1210/jc.2009-0960

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Gomes MB, Conte D, Drummond KRG, Mallmann F, Pinheiro AA, Leal FSL, et al. Overweight/obesity in adolescents with type 1 diabetes belonging to an admixed population. a Brazilian multicenter study. Diabetol Metab Syndr (2022) 14(1):1. doi: 10.1186/s13098-021-00759-9

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Jaiswal M, Divers J, Dabelea D, Isom S, Bell RA, Martin CL, et al. Prevalence of and risk factors for diabetic peripheral neuropathy in youth with type 1 and type 2 diabetes: SEARCH for diabetes in youth study. Diabetes Care (2017) 40(9):1226–32. doi: 10.2337/dc17-0179

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Franceschi R, Mozzillo E, Di Candia F, Rosanio FM, Leonardi L, Liguori A, et al. A systematic review of the prevalence, risk factors and screening tools for autonomic and diabetic peripheral neuropathy in children, adolescents and young adults with type 1 diabetes. Acta Diabetol (2022) 59(3):293–308. doi: 10.1007/s00592-022-01850-x

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Kazamel M, Stino AM, Smith AG. Metabolic syndrome and peripheral neuropathy. Muscle Nerve (2021) 63(3):285–93. doi: 10.1002/mus.27086

PubMed Abstract | CrossRef Full Text | Google Scholar

17. The DCCT Research Group. Weight gain associated with intensive therapy in the diabetes control and complications trial. the DCCT research group. Diabetes Care (1988) 11(7):567–73. doi: 10.2337/diacare.11.7.567

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Diabetes Control and Complications Trial (DCCT)/Epidemiology of Diabetes Interventions and Complications (EDIC) Study Research Group. Intensive diabetes treatment and cardiovascular outcomes in type 1 diabetes: The DCCT/EDIC study 30-year follow-up. Diabetes Care (2016) 39(5):686–93. doi: 10.2337/dc15-1990

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Casu A, Bilal A, Pratley RE. Advancing care for type 1 diabetes, obesity network (ACT1ON). pharmacological therapies to address obesity in type 1 diabetes. Curr Opin Endocrinol Diabetes Obes (2020) 27(4):194–206. doi: 10.1097/MED.0000000000000555

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Driscoll KA, Corbin KD, Maahs DM, Pratley R, Bishop FK, Kahkoska A, et al. Advancing care for type 1 diabetes and obesity network (ACT1ON). biopsychosocial aspects of weight management in type 1 diabetes: A review and next steps. Curr Diabetes Rep (2017) 17(8):58. doi: 10.1007/s11892-017-0892-1

CrossRef Full Text | Google Scholar

21. Myśliwiec A, Lejk A, Skalska M, Jastrzębska J, Sztangierska B, Jastrzębski Z. Assessment of the diet of male adolescents suffering from type 1 diabetes. Pediatr Endocrinol Diabetes Metab (2021) 27(1):7–11. doi: 10.5114/pedm.2020.101805

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Minges KE, Whittemore R, Grey M. Overweight and obesity in youth with type 1 diabetes. Annu Rev Nurs Res (2013) 31:47–69. doi: 10.1891/0739-6686.31.47

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Zaharieva DP, Addala A, Simmons KM, Maahs DM. Weight management in youth with type 1 diabetes and obesity: Challenges and possible solutions. Curr Obes Rep (2020) 9(4):412–23. doi: 10.1007/s13679-020-00411-z

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Mottalib A, Kasetty M, Mar JY, Elseaidy T, Ashrafzadeh S, Hamdy O. Weight management in patients with type 1 diabetes and obesity. Curr Diabetes Rep (2017) 17(10):92. doi: 10.1007/s11892-017-0918-8

CrossRef Full Text | Google Scholar

25. Chetty T, Shetty V, Fournier PA, Adolfsson P, Jones TW, Davis EA. Exercise management for young people with type 1 diabetes: A structured approach to the exercise consultation. Front Endocrinol (Lausanne) (2019) 10:326. doi: 10.3389/fendo.2019.00326

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Biester T, Tauschmann M, Chobot A, Kordonouri O, Danne T, Kapellen T, et al. The automated pancreas: A review of technologies and clinical practice. Diabetes Obes Metab (2022) 24 Suppl 1:43–57. doi: 10.1111/dom.14576

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Russell-Jones D, Khan R. Insulin-associated weight gain in diabetes–causes, effects and coping strategies. Diabetes Obes Metab (2007) 9(6):799–812. doi: 10.1111/j.1463-1326.2006.00686.x

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Yeh HC, Brown TT, Maruthur N, Ranasinghe P, Berger Z, Suh YD, et al. Comparative effectiveness and safety of methods of insulin delivery and glucose monitoring for diabetes mellitus: a systematic review and meta-analysis. Ann Intern Med (2012) 157(5):336–47. doi: 10.7326/0003-4819-157-5-201209040-00508

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Study Group REPOSE. Relative effectiveness of insulin pump treatment over multiple daily injections and structured education during flexible intensive insulin treatment for type 1 diabetes: cluster randomised trial (REPOSE). BMJ (2017) 356:j1285. doi: 10.1136/bmj.j1285

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Boucher-Berry C, Parton EA, Alemzadeh R. Excess weight gain during insulin pump therapy is associated with higher basal insulin doses. J Diabetes Metab Disord (2016) 15:47. doi: 10.1186/s40200-016-0271-5

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Oldham V, Mumford B, Lee D, Jones J, Das G. Impact of insulin pump therapy on key parameters of diabetes management and diabetes related emotional distress in the first 12 months. Diabetes Res Clin Pract (2020) 166:108281. doi: 10.1016/j.diabres.2020.108281

PubMed Abstract | CrossRef Full Text | Google Scholar

32. World Health Organization. BMI . Available at: https://www.who.int/tools/growth-reference-data-for-5to19-years/indicators/bmi-for-age (Accessed 25 August 2022).

Google Scholar

33. GlyCulator 3.0 software. Available at: https://glyculator.btm.umed.pl/ (Accessed 25 August 2022).

Google Scholar

34. Elbarbary NS A, Ismail EAR. Glycemic control during Ramadan fasting in adolescents and young adults with type 1 diabetes on MiniMed™ 780G advanced hybrid closed−loop system: A randomized controlled trial. Diabetes Res Clin Pract (2022) 191:110045. doi: 10.1016/j.diabres.2022.110045

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Karakuş KE, Yeşiltepe Mutlu G, Gökçe T, Eviz E, Can E, Muradoğlu S, et al. Insulin requirements for basal and auto-correction insulin delivery in advanced hybrid closed-loop system: 4193 days' real-world data of children in two different age groups. J Diabetes Sci Technol (2022) 30. doi: 10.1177/19322968221106194

CrossRef Full Text | Google Scholar

36. Tornese G, Buzzurro F, Carletti C, Faleschini E, Barbi E. Six-month effectiveness of advanced vs. standard hybrid closed-loop system in children and adolescents with type 1 diabetes mellitus. Front Endocrinol (Lausanne) (2021) 12:766314. doi: 10.3389/fendo.2021.766314

PubMed Abstract | CrossRef Full Text | Google Scholar

37. Petrovski G, Al Khalaf F, Campbell J, Day E, Almajaly D, Hussain K, et al. Successful transitioning children and adolescents with type 1 diabetes from multiple daily injections to advanced hybrid closed-loop system in 10 days: a prospective intervention study on MiniMed 780G system. Acta Diabetol (2022) 59(5):743–6. doi: 10.1007/s00592-022-01851-w

PubMed Abstract | CrossRef Full Text | Google Scholar

38. Bergenstal RM, Nimri R, Beck RW, Criego A, Laffel L, Schatz D, et al. FLAIR study group. a comparison of two hybrid closed-loop systems in adolescents and young adults with type 1 diabetes (FLAIR): A multicentre, randomised, crossover trial. Lancet (2021) 397(10270):208–19. doi: 10.1016/S0140-6736(20)32514-9

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Beato-Víbora PI, Gallego-Gamero F, Ambrojo-López A, Gil-Poch E, Martín-Romo I, Arroyo-Díez FJ. Rapid improvement in time in range after the implementation of an advanced hybrid closed-loop system in adolescents and adults with type 1 diabetes. Diabetes Technol Ther (2021) 23(9):609–15. doi: 10.1089/dia.2021.0037

PubMed Abstract | CrossRef Full Text | Google Scholar

40. Carlson AL, Sherr JL, Shulman DI, Garg SK, Pop-Busui R, Bode BW, et al. Safety and glycemic outcomes during the MiniMed™ advanced hybrid closed-loop system pivotal trial in adolescents and adults with type 1 diabetes. Diabetes Technol Ther (2022) 24(3):178–89. doi: 10.1089/dia.2021.0319

PubMed Abstract | CrossRef Full Text | Google Scholar

41. Collyns OJ, Meier RA, Betts ZL, Chan DSH, Frampton C, Frewen CM, et al. Improved glycemic outcomes with medtronic MiniMed advanced hybrid closed-loop delivery: Results from a randomized crossover trial comparing automated insulin delivery with predictive low glucose suspend in people with type 1 diabetes. Diabetes Care (2021) 44(4):969–75. doi: 10.2337/dc20-2250

PubMed Abstract | CrossRef Full Text | Google Scholar

42. Matejko B, Juza A, Kieć-Wilk B, Cyranka K, Krzyżowska S, Chen X, et al. Transitioning of people with T1D from multiple daily injections and self-monitoring of blood glucose directly to MiniMed 780G advanced hybrid closed loop system: A two-center, randomized, controlled study. Diabetes Care (2022) 15:dc220470. doi: 10.2337/dc22-0470

CrossRef Full Text | Google Scholar

43. Piccini B, Pessina B, Barni F, Benucci F, Casalini E, Farina S, et al. Metabolic control in type 1 diabetes patients switching to advanced hybrid closed loop. Pediatr Diabetes (2021) 22(Suppl. S30):65. doi: 10.1111/pedi.13269

CrossRef Full Text | Google Scholar

44. Arrieta A, Battelino T, Scaramuzza AE, Da Silva J, Castañeda J, Cordero TL, et al. Comparison of MiniMed 780G system performance in users aged younger and older than 15 years: Evidence from 12 870 real-world users. Diabetes Obes Metab (2022) 24(7):1370–9. doi: 10.1111/dom.14714

PubMed Abstract | CrossRef Full Text | Google Scholar

45. Seget S, Rusak E, Polanska J, Jarosz-Chobot P. Prospective open-label, single-arm, single-center follow-up study of the application of the advanced hybrid closed loop system in well-controlled children and adolescents with type 1 diabetes. Diabetes Technol Ther (2022) 4. doi: 10.1089/dia.2022.0148

CrossRef Full Text | Google Scholar

Keywords: advanced hybrid closed-loop system, type 1 diabetes, children, body mass index, bmi, basal insulin, total daily insulin dose, time in range

Citation: Seget S, Jarosz-Chobot P, Ochab A, Polanska J, Rusak E, Witoszek P and Chobot A (2022) Body mass index, basal insulin and glycemic control in children with type 1 diabetes treated with the advanced hybrid closed loop system remain stable - 1-year prospective, observational, two-center study. Front. Endocrinol. 13:1036808. doi: 10.3389/fendo.2022.1036808

Received: 05 September 2022; Accepted: 21 September 2022;
Published: 11 October 2022.

Edited by:

Artur Mazur, University of Rzeszow, Poland

Reviewed by:

Barbara Glowinska-Olszewska, Medical University of Bialystok, Poland
Ewa Otto-Buczkowska, Medical Center, Poland

Copyright © 2022 Seget, Jarosz-Chobot, Ochab, Polanska, Rusak, Witoszek and Chobot. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Agata Chobot, agata.chobot@uni.opole.pl

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.