Skip to main content

TECHNOLOGY AND CODE article

Front. Earth Sci., 13 December 2019
Sec. Volcanology
This article is part of the Research Topic Advanced Time Series Analysis in Geosciences View all 13 articles

VINEDA—Volcanic INfrasound Explosions Detector Algorithm

  • 1Department of Signal Theory, Telematics and Communications, University of Granada, Granada, Spain
  • 2Department of Earth, Ocean and Ecological Sciences, University of Liverpool, Liverpool, United Kingdom
  • 3Department of Geological Sciences, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States
  • 4Department of Theoretical Physics and Cosmos, University of Granada, Granada, Spain
  • 5Istituto Nazionale di Geofisica e Vulcanologia, Sezione di Pisa, Pisa, Italy

Infrasound is an increasingly popular tool for volcano monitoring, providing insights of the unrest by detecting and characterizing acoustic waves produced by volcanic processes, such as explosions, degassing, rockfalls, and lahars. Efficient event detection from large infrasound databases gathered in volcanic settings relies on the availability of robust and automated workflows. While numerous triggering algorithms for event detection have been proposed in the past, they mostly focus on applications to seismological data. Analyses of acoustic infrasound for signal detection is often performed manually or by application of the traditional short-term average/long-term average (STA/LTA) algorithms, which have shown limitations when applied in volcanic environments, or more generally to signals with poor signal-to-noise ratios. Here, we present a new algorithm specifically designed for automated detection of volcanic explosions from acoustic infrasound data streams. The algorithm is based on the characterization of the shape of the explosion signals, their duration, and frequency content. The algorithm combines noise reduction techniques with automatic feature extraction in order to allow confident detection of signals affected by non-stationary noise. We have benchmarked the performances of the new detector by comparison with both the STA/LTA algorithm and human analysts, with encouraging results. In this manuscript, we present our algorithm and make its software implementation available to other potential users. This algorithm has potential to either be implemented in near real-time monitoring workflows or to catalog pre-existing databases.

1. Introduction

Seismic and acoustic signals are key in monitoring and characterizing volcanic unrest. Recent technological advances in sensor development, data transmission, and archival protocols have made the collection of large amounts of geophysical data commonplace at active volcanoes and other monitoring environments. The sheer amount of data recorded makes their manual analysis a challenging, frequently unfeasible, task. The implementation of automated tools to address this challenge is, thus, vital for effective monitoring operations.

Automatic event detection and classification work-flows applied to seismic data include an initial segmentation stage, commonly via the application of short-term average/long-term average (STA/LTA) algorithms in order to parse the continuous seismograms into individual earthquake waveforms with varied characteristics and sources (Allen., 1982). In more advanced processing work-flows, this is followed by automatic classification of the signals by different methods, including Neural Networks (Scarpetta et al., 2005), pattern recognition (e.g., Curilem et al., 2014), Hidden Markov Models (Ibáñez et al., 2009), Support Vector Machines (Giacco et al., 2009), or statistical properties (Bueno et al., 2019). A wealth of new algorithms are constantly published in the literature in order to improve the efficiency of automatic detection and classification procedures for different types of signals, including those associated with tectonic earthquakes (Di Stefano et al., 2006; Álvarez et al., 2013; Bhatti et al., 2016), low-frequency volcano-seismic events (Frank and Shapiro, 2014), avalanches (Marchetti et al., 2015), and debris flows (Schimmel and Hübl, 2016). Collectively, these algorithms represent an important toolbox for the creation of high-quality research databases.

Volcano infrasound is becoming increasingly popular as a monitoring tool (Johnson and Ripepe, 2011; Fee et al., 2013); among other applications, acoustic data are frequently used for detection and characterization of explosive volcanic activity (e.g., Garcés et al., 1999; Johnson et al., 2004; Vergniolle and Ripepe, 2008; Caplan-Auerbach et al., 2010; Fee and Matoza, 2013; Lamb et al., 2015; De Angelis et al., 2019). Volcanic explosions are commonly recorded by infrasound microphones in the 0.01–20 Hz frequency band as signals characterized by impulsive onsets followed by codas with variable duration, from few seconds to several minutes. Due to the increasing amount of acoustic infrasound data routinely collected on active volcanoes, the development of tools for automated signal detection is crucial for efficient monitoring. Here, we introduce an adaptative infrasound detector based on time- and frequency-domain characterization of volcanic explosion signals. We take advantage of advanced signal processing techniques, in combination with a-priori knowledge of recorded explosions, to implement a robust infrasound detector based on adaptive multi-band processing. The datasets selected for this study are obtained from two previous monitoring campaigns at Santiaguito (Lamb et al., 2019) and Mount Etna (Diaz-Moreno et al., 2019) volcanoes. On Mount Etna volcano, Diaz-Moreno et al. (2019) studied an inversion modeling workflow to derive infrasound acoustic sources and estimate rate and volume of erupted materials. On Santiaguito volcano, Lamb et al. (2019) provides a seismic and infrasound analysis of three eruptive phases in a multi-parametric monitoring framework, associating infrasound and seismic signals. Hence, the sheer volume of recorded explosions at both volcanoes makes an ideal ground for testing the VINEDA algorithm, as the geological properties are already known.

2. Detection of Infrasound Explosions

2.1. Algorithm Description

Detection of volcanic explosions in infrasound data streams is an important and challenging task. The algorithm detailed here, the Volcanic INfrasound Explosions Detector Algorithm (VINEDA), parses raw acoustic data streams, x(n) into a normalized characteristic function (CF) within a given frequency range [flow,fhigh]; the frequency band is chosen to include the majority of energy transported by explosion infrasound. Explosion temporal boundaries are defined by the abrupt onset arrival and return to background amplitude, with expected average durations given by D = {DminDmax}, with Dmin and Dmax the minimum and maximum expected duration of infrasound explosions, respectively. The number of duration bands used in the discriminant analysis is defined as Ndb. Background amplitude is defined as characteristic low-amplitude stationary signals (i.e., wind, noise, or lack of infrasound activity). The data processing pipeline is illustrated in Figure 1, key parameters for the algorithm are given in Algorithm 1, and Figure 2 shows the outputs of each step of the workflow using infrasound recorded of an explosion at Santiaguito volcano, Guatemala.

FIGURE 1
www.frontiersin.org

Figure 1. VINEDA Algorithm block diagram. (A) The signal is decimated and filtered in order to suppress noise and avoid spike distortions. (B) Successive steps focus on the detection of infrasound explosions onset, using specialized designed filters and a discriminant detector based on a priori knowledge of the infrasonic explosions. The computed characteristic function CF contains the detected explosions.

ALGORITHM 1
www.frontiersin.org

Algorithm 1 VINEDA parameters definition.

FIGURE 2
www.frontiersin.org

Figure 2. Output example for all intermediate steps of the VINEDA workflow. (A) The original infrasound signal of an explosion at Santiaguito volcano, Guatemala, x(n). (B) The signal y(n′) is the output after decimation, detrending and median filtering stages. (C) The signal e(n′) represents the output of the no edge delay filter bank. (D) A characteristic function CF(n′) is obtained from the signal, which can be used to perform the automatic detection. (E) Example of the impulse response of the bandpass filters. (F) Impulse response for the proposed discriminant detector (Álvarez et al., 2013).

As the first step, an anti-aliasing Finite Impulse Response (FIR) low-pass filter is applied with a corner frequency fhigh, corresponding to the highest frequency component of interest in the explosion signal investigated. This stage eliminates noise outside the frequency band of interest for explosions, eases computational load and reduces signal complexity, while preserving important signal onset information. The sampling frequency, fs, is usually much higher than fhigh (typical values for fs and fhigh are of the order of 100 Hz and below 5 Hz, respectively); this allows, in the second processing step, downsampling of the input signal, x(n), by a factor of R = fs/fs′, being fs=2·fhigh. Downsampling is performed by a poly-phase anti-aliasing filter to compensate for potential delays due to re-sampling computations.

An adaptive de-trending filter is then applied to remove noise that could affect the lower frequency range of infrasound explosions, such as from wind or long-period instrument drift. Detrending is implemented as a zero-phase high-pass FIR filter. The order of this filter is given by the maximum duration of the explosion (Dmax), whereas the cutoff frequency is fixed at flow Hz. This filter also helps to mitigate the influence of low frequency noise, such as microbaroms, which is often located at very low frequency bands (i.e. [0.1–0.5] Hz) (Landès et al., 2012) A median filter is further applied to remove spikes in the signal, such as those associated with instrument or data transmission noise. This filter reduces extreme values and smooths the input signal (Figure 2B).

Since explosions are characterized by sharp onsets, a multi-band filter stage has been specifically designed to provide no edge delay (Álvarez et al., 2013). The design of the filter bank (number of bands, central frequencies and bandwidths) depends on the frequency content of the explosions to be detected. Figure 2E depicts an instance of the impulse response of the FIR filters designed. The center frequencies are uniformly distributed within the frequency band of the explosion signal [flow, fhigh], according to:

fck=flow+(k-1)·(fhigh-flow)Nfb            +12·(fhigh-flow)Nfbwithk=1,,Nfb    (1)

where Nfb is the number of sub-bands of the filter bank.

Once the multi-bank filter is applied, signal envelopes are computed within each sub-band; the envelope, ek(n), for each sub-band is estimated as:

ek(n)=sk(n)2+sk^(n)2withk=1,Nfb    (2)

where sk^(n) is the Hilbert Transform of sk(n) (Bracewell, 1999). All the sub-band envelopes are then added to obtain the signal e(n′). This global envelope allows characterizing how energy is delivered at the explosion onset (i.e., an abrupt rise followed by a slow decay). Figure 2C shows the detected envelope e(n′) of the explosion. The abrupt onset is detected, and the smooth decay is preserved.

The next step in the detection algorithm is the application of a discriminant filter to the signal e(n′) in order to compute a characteristic function, CF(n′), and detect explosion onsets (Figure 2D). The impulse response h(n′) of the proposed discriminant filter is shown in Figure 2F; this filter is designed to enhance signals with a sharp rise and gradual decay, such as infrasound explosions, with a duration in the order of D. Thus, the discriminant detector mitigates the effect of non-stationary noises while finding the best match of infrasonic signals (Álvarez et al., 2013). A penalty factor for non-impulsive onsets, β, is added to increase the robustness of the filter with respect to background noise. The value of β controls the impulsivity of the signal we are going to detect, and it should be selected on the basis of the expected onset. Larger β values are required to detect very impulsive onsets with respect to background noise.

In the final stage of the detection workflow, the characteristic function, CF(n′), is normalized following a non-linear companding method to emphasize onset arrivals without loosing amplitude information (Rabiner and Gold, 1975). The peak of CF(n′) corresponds to the onset of the detected explosion event (Figure 2D).

The sequence of filtering stages is summarized in Figures 2A–D. Note that the spike present in the raw signal x(n) at ~18 s is suppressed during processing and the long-period trend is removed while the onset of the explosion signal is preserved. The CF(n′) for the original explosion waveform is shown in Figure 2D. The amplitude of the CF is proportional to the sharpness of the original explosion onset. Notice that the discriminant detector has suppressed background noise, thus highlighting the explosion onset.

Finally, VINEDA is designed to be used with any single-station recordings. However, the flexibility of VINEDA allows its configuration in a parallel framework to work in a multi-station setting. Once the signals have been detected, derived CFs can be merged or interfaced with physical propagation models to locate the events of interest.

2.2. Multi-Station Application Example on Etna Volcano

VINEDA is a highly flexible algorithm that can be applied to network data to enhance detection of infrasound signals associated with volcanic explosions. Here, we demonstrate an application to network data recorded at Mt. Etna volcano by three infrasound sensors, during June 2017, with a frequency content between [1.0–3.0] Hz and maximum duration of Dmax = 5.0 s (Diaz-Moreno et al., 2019). Each sensor is independently processed, as we aim to investigate how VINEDA detects infrasound explosions from stations installed at different locations from the volcanic vent.

Figure 3 shows the CFs along with signal envelopes (e1(n), e2(n), e3(n)) for each of the input signals (x1(n), x2(n), x3(n)). Note that, generally, the proposed pre-processing steps yield robust envelopes, as noise and long-period trends have been filtered out, and the no-edge delay filter along with the envelope detector characterize explosion onsets. However, when stations are closer to the vent, the recorded explosions are less attenuated with larger amplitudes and more obvious onsets (ET01, ET04, and ET10 located at 1.0, 1.3, and 6 km from the vent, respectively; Diaz-Moreno et al., 2019). While closer stations exhibit larger CFs as observed for CF1(n) and CF2(n), the detector is still able to observe a signal at the farthest station, CF3(n). The results presented in Figure 3 highlight the capabilities of VINEDA to suppress much of the noise and still being able to detect attenuated explosions at greater distances. The robustness of the algorithm to perform multi-station detection permits a direct embedding with atmospheric propagation models to compute travel times based on VINEDA detections, thus reducing false positives and easing the location of infrasound sources.

FIGURE 3
www.frontiersin.org

Figure 3. Application example on a multi-station configuration at Etna volcano in three different stations (ET01, ET04, and ET10 located at 1.0, 1.3, and 6 km from the vent, respectively; Diaz-Moreno et al., 2019). Even if attenuated, the detector can recognize explosions at distant stations. When deployed on a single station, CF3 could be considered as a false positive. However, when complemented with other CFs and propagation models, the number of false positives could be further reduced.

3. Data Experimentation and Results

We applied the VINEDA algorithm to infrasound data from low-intensity Strombolian explosions recorded at Mt. Etna volcano during an experiment in the summer of 2017 (Diaz-Moreno et al., 2019). Additionally, the generalization capabilities of the algorithm across different volcanic settings are tested with infrasound data from Santiaguito (Lamb et al., 2019). A traditional STA/LTA algorithm is compared with VINEDA in order to assess its detection performance and robustness. In addition, 2 days of continuous data from both volcanoes were also manually evaluated by a group of 6 experts. For every waveform of a detected event, each individual expert checks the presence/absence of an event and assign a quality factor Q. Faced with the question “Is this an explosion?”, experts chose one of three quality assessments: “strongly agree” (Q = 1), “agree” (Q = 2), and “undecided” (Q = 3). Figure 4 depicts three infrasound signals with different quality factors, as reviewed by experts. Notice that signal to noise ratio (SNR) along is the highest for Q1, where the explosion is clearly visible. For lower quality values, the segmented explosion is almost masked with background fluctuations. All our experiments were performed on a 64 bit computer with an i7-8700k CPU (3.70 GHz) processor, 16 GB RAM, and Ubuntu 16.04. On this machine, VINEDA takes and average of 0.72 s (over 10 runs) to process 1 day of infrasound data of both volcanoes.

FIGURE 4
www.frontiersin.org

Figure 4. Infrasound signals from Etna 2017 experiment, as presented to the experts during the annotation process. The assigned quality factors (Q1,Q2,Q3) is also shown. Notice that the highest quality of Q1 implies the best signal to noise ratio, with the explosion clearly distinguishable. For Q2, the event is detected by VINEDA, despite lower amplitude values. For Q3, atmospheric disturbances affect the infrasound signal, and even if the explosion is detected, a multi-station analysis would help to decrease false positives.

The Receiver Operating Characteristic (ROC) curve is an excellent graphical technique to visualize the trade-off between the sensitivity and the specificity of any detection system, for a particular decision threshold (Fawcett, 2006). The sensitivity is a metric to evaluate the goodness of a model to detect true events and according to the common definition from Signal Detection Theory, the sensitivity can be calculated as:

sensitivity=TPFN+TP

where infrasound explosions are successfully detected (making a true positive, TP), mistakenly ignored (making a false negative, FN), and vice versa: other events or noise can be mistakenly detected as explosions (making a false positive, FP).

The specificity measures the proportion of actual negatives that are correctly identified as such. Since VINEDA is a detector (it detects infrasound explosions in an input signal in which an event could be found at any time) but not a classifier, the specificity of the detector is expressed as the rate of false positives per hour (FP/h).

Figure 5 illustrates the ROC curves of detection for Etna (left) and Santiaguito (right) volcanoes performed by VINEDA algorithm (red) when compared to STA/LTA algorithm (blue), and two quality criteria Q ≤ 2 and Q ≤ 3 as assessed by human analysts. For Santiaguito volcano, explosions were characterized by a duration of 4 s, with a frequency content in the range of [1.0–3.0] Hz. Mount Etna explosions were characterized by an average duration of 2 s, and a frequency content in the range of [1.0–3.0] Hz. In both settings the parameters β and Nfb were fixed to 3. Note that, from Equation (1), a Nfb = 3 yields a set of central frequencies that covers the range of infrasonic explosions for both volcanoes. The definition of the frequency band [flow, fhigh] is essential to guarantee correct segmentation boundaries. For Etna and Santiaguito volcano with given band of 1.0–3.0 Hz., the computed frequencies for the multi-band analysis are fc = [1.33, 2.00, 2.67] (see Equation 1), encompassing the range of frequencies of interest for all explosive activity analyzed. Similarly, a value of β = 3 helps to select events with sharp onsets mitigating the influence of the background noise. Given the mathematical design of the discriminant filter, larger values of β fit sharp onsets whilst decreasing the computed CF function for smaller (or attenuated) explosions. The vector range of durations D is defined, for both volcanoes and a delta time-step of 1 s, between Dmin = 2.0 and Dmax = 5.0 s. In practice, the selected parameters suffice for the range of frequencies in infrasonic explosions for these volcanoes, but this definition is highly flexible and is left to the analyst on a per-case basis.

FIGURE 5
www.frontiersin.org

Figure 5. ROC curve for ETNA (A) and Santiaguito (B) volcanoes comparing VINEDA and STA/LTA algorithms for different quality assessments of the experts (thr = thresholds).

All streams were sampled at fs = 100 Hz. The detection thresholds (thr) varied between 0 and 240. STA/LTA is a simple and effective method to detect transient events that defines a characteristic function for detection as the ratio between the STA and the LTA (the absolute values of the seismogram averaged over short and long windows, respectively). In such way, the LTA tracks the background seismic noise, while the STA/LTA ratio increases when there is a sudden increase in signal amplitude (Allen., 1982). Using the infrasound data gathered at Santiaguito and Mount Etna, STA/LTA was applied to the band of interest ([1.0–3.0] Hz for both volcanoes), with short and long windows of 1 and 10 s, respectively.

The area under the ROC curve could provide an idea of the benefits of any particular algorithm. For an algorithm with a good performance, the area under this curve would be maximum since the ideal detection threshold would be the one providing a result closest to Sensitivity = 1 and FP/h = 0. Figure 5 shows that VINEDA detector outperforms STA/LTA for both volcanoes. The performance including events in which experts are “sure” (Q ≤ 2) is better than that for “not sure” events (Q ≤ 3) in all cases. The improvement in sensitivity and rate of false positives per hour for VINEDA compared to STA/LTA in all cases is associated to the specific processing of infrasound explosion signals that the algorithm VINEDA carries out. The maximum value of the CF function depends on the quality of the explosion signal. Figure 6 shows the real value of the CF against the quality factor assigned by the experts, in combination with the total number of detected explosions (N). We observe that higher values on the CF function are obtained for events with better quality. These events would be detected using high values of the detection threshold, while keeping the number of detected explosions low. This is in line with the design of the algorithm, as restrictive detection thresholds will only retrieve very distinctive explosions with abrupt onsets, discarding the rest. By contrast, for less demanding thresholds, the number of detected explosions increases but the maximum value of the CF decreases. This behavior is expected, and should be taken into account to set the detection threshold depending on the particular needs or application.

FIGURE 6
www.frontiersin.org

Figure 6. Values of the characteristic function in the VINEDA algorithm for Etna (A) and Santiaguito (B) volcanoes, for the events manually assessed by the experts with the three different quality criterion considered: “strongly agree” (Q = 1), “agree” (Q = 2), and “undecided” (Q = 3). N indicates the total number of detected explosions by the algorithm with the assigned quality factor.

The ever-increasing availability of infrasonic data requires the development of mathematical routines that can be used to detect events of geophysical interest. We have presented VINEDA; a generic and scalable multi-step algorithm designed to detect infrasound explosions. Our experimental evaluation with data from two volcanoes, Santiaguito and Etna, suggest that VINEDA improves performance over STA/LTA approaches. For both volcanoes, the refinement of the detector shown in the ROC curve, jointly with the value of the estimated CF function, confirms the capabilities of VINEDA to surpass STA/LTA. The discriminant detector helps to filter out non-stationary noises and acts as a penalty to temporally longer infrasound events, such as rockfalls, avalanches, or degassing. Further, the quality of detections is strengthened by VINEDA's capabilities to function in a multi-station setting. We suggest that the procedure described here can be used to annotate high-quality data from sequential infrasound streams for further post-processing, including the training of advanced machine learning models, picking algorithms or geo-statistical modeling.

4. Conclusions

Acoustic infrasound provides unique insights on the dynamics of erupting volcanoes. The detection and characterization of explosions from large streams of continuous, multi-channel, infrasound data is a challenging task. In this manuscript, we have introduced VINEDA, an infrasound detector which makes extensive use of signal processing techniques in order to characterize continuous volcano acoustic records and extract explosion signals. This algorithm stands as a middle point between the complete knowledge of the target signal beforehand, and incomplete knowledge of the explosions on the recorded infrasonic-stream as some prior knowledge of signal features suffice for VINEDA to detect target signals. VINEDA is suitable for deployment within volcano monitoring systems and offers a trade-off between quality and quantity of detections. We suggest that real-time implementations of algorithms like VINEDA are crucial to improve existing infrasound datasets and ultimately, increase our ability to monitor unrest at active volcanoes.

Data Availability Statement

The Santiaguito and Etna infrasound datasets selected for this study are available via request to the authors. VINEDA code is open-source and can be downloaded at https://github.com/srsudo/vineda.

Author Contributions

AB, AD-M, and IÁ developed and implemented the VINEDA algorithm, wrote the manuscript, and produced the figures. AD revised the signal processing part. OL, LZ, and SD contributed to data-gathering, data quality checking, software testing, and infrasound theoretical discussions. All authors contributed to the manuscript reviews and distribution of ideas.

Funding

This research was partially funded by KNOWAVES TEC2015-68752 (MINECO/FEDER), by NERC Grant NE/P00105X/1, by Spanish research grant MECD Jose Castillejo CAS17/00154 and by VOLCANOWAVES European Union's Horizon 2020 Research and Innovation Programme Under the Marie Sklodowska-Curie Grant Agreement no 798480.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Acknowledgments

We would like to thank all the members at the Seismic Laboratory at University of Liverpool for continuous support and advice when developing this algorithm. We thank John Lyons and the other reviewer for their suggestions and comments which have improved VINEDA.

References

Allen, R. (1982). Automatic phase pickers: their present use and future prospects. Bull. Seismol. Soc. Am. 72, S225–S242.

Google Scholar

Álvarez, I., García, L., Mota, S., Cortés, G., Benítez, C., and Torre, Á. D. (2013). An automatic P-phase picking algorithm based on adaptive multiband processing. IEEE Geosci. Rem. Sens. Lett. 10, 1488–1492. doi: 10.1109/LGRS.2013.2260720

CrossRef Full Text | Google Scholar

Bhatti, S. M., Khan, M. S., Wuth, J., Huenupan, F., Curilem, M., Franco, L., et al. (2016). Automatic detection of volcano-seismic events by modeling state and event duration in Hidden Markov Models. J. Volcanol. Geotherm. Res. 324, 134–143. doi: 10.1016/j.jvolgeores.2016.05.015

CrossRef Full Text | Google Scholar

Bracewell, R. N. (1999). The Fourier Transform and Its Applications. 3rd Edn. New York, NY.

Google Scholar

Bueno, A., Díaz-Moreno, A., De-Angelis, S., Benítez, C., and Ibáñez, J. M. (2019). Recursive entropy method of segmentation. Seismol. Res. Lett. 90, 1670–1677. doi: 10.1785/0220180317

CrossRef Full Text | Google Scholar

Caplan-Auerbach, J., Bellesiles, A., and Fernandes, J. K. (2010). Estimates of eruption velocity and plume height from infrasonic recordings of the 2006 eruption of augustine volcano, alaska. J. Volcanol. Geotherm. Res. 189, 12–18. doi: 10.1016/j.jvolgeores.2009.10.002

CrossRef Full Text | Google Scholar

Curilem, M., Vergara, J., San Martin, C., Fuentealba, G., Cardona, C., Huenupan, F., et al. (2014). Pattern recognition applied to seismic signals of Llaima volcano (Chile): an analysis of the events' features. J. Volcanol. Geotherm. Res. 282, 134–147. doi: 10.1016/j.jvolgeores.2014.06.004

CrossRef Full Text | Google Scholar

De Angelis, S., Diaz-Moreno, A., and Zuccarello, L. (2019). Recent developments and applications of acoustic infrasound to monitor volcanic emissions. Rem. Sens. 11:1302. doi: 10.3390/rs11111302

CrossRef Full Text | Google Scholar

Di Stefano, R., Aldersons, F., Kissling, E., Baccheschi, P., Chiarabba, C., and Giardini, D. (2006). Automatic seismic phase picking and consistent observation error assessment: application to the Italian seismicity. Geophys. J. Int. 165, 121–134. doi: 10.1111/j.1365-246X.2005.02799.x

CrossRef Full Text | Google Scholar

Diaz-Moreno, A., Iezzi, A. M., Lamb, O., Fee, D., Kim, K., Zuccarello, L., et al. (2019). Volume flow rate estimation for small explosions at Mt. Etna, Italy, from acoustic waveform inversion. Geophys. Res. Lett. 46, 11071–11079. doi: 10.1029/2019GL084598

CrossRef Full Text | Google Scholar

Fawcett, T. (2006). An introduction to roc analysis. Pattern Recogn. Lett. 27, 861–874. doi: 10.1016/j.patrec.2005.10.010

CrossRef Full Text | Google Scholar

Fee, D., and Matoza, R. (2013). An overview of volcano infrasound: from Hawaiian to Plinian, local to global. J. Volcanol. Geotherm. Res. 249, 123–139. doi: 10.1016/j.jvolgeores.2012.09.002

CrossRef Full Text | Google Scholar

Fee, D., McNutt, S. R., Lopez, T. M., Arnoult, K. M., Szuberla, C. A., and Olson, J. V. (2013). Combining local and remote infrasound recordings from the 2009 Redoubt Volcano eruption. J. Volcanol. Geotherm. Res. 259, 100–114. doi: 10.1016/j.jvolgeores.2011.09.012

CrossRef Full Text | Google Scholar

Frank, W. B., and Shapiro, N. M. (2014). Automatic detection of low-frequency earthquakes (LFEs) based on a beamformed network response. Geophys. J. Int. 124, 8611–8625. doi: 10.1093/gji/ggu058

CrossRef Full Text | Google Scholar

Garcés, M., Iguchi, M., Ishihara, K., Morrissey, M., Sudo, Y., and Tsutsui, T. (1999). Infrasonic precursors to a vulcanian eruption at sakurajima volcano, japan. Geophys. Res. Lett. 26, 2537–2540. doi: 10.1029/1998GL005327

CrossRef Full Text | Google Scholar

Giacco, F., Esposito, A., Scarpetta, S., Giudicepietro, F., and Marinaro, M. (2009). Support vector machines and mlp for automatic classification of seismic signals at stromboli volcano. Front. Artif. Intell. Appl. 204:116. doi: 10.3233/978-1-60750-072-8-116

CrossRef Full Text | Google Scholar

Ibáñez, J., Benítez, C., Gutiérrez, L., Cortés, G., García-Yeguas, A., and Alguacil, G. (2009). The classification of seismo-volcanic signals using hidden markov models as applied to the Stromboli and Etna volcanoes. J. Volcanol. Geotherm. Res. 187, 218–226. doi: 10.1016/j.jvolgeores.2009.09.002

CrossRef Full Text | Google Scholar

Johnson, J. B., Aster, R. C., and Kyle, P. R. (2004). Volcanic eruptions observed with infrasound. Geophys. Res. Lett. 31:L14604. doi: 10.1029/2004GL020020

CrossRef Full Text | Google Scholar

Johnson, J. B., and Ripepe, M. (2011). Volcano infrasound: a review. J. Volcanol. Geotherm. Res. 206, 61–69. doi: 10.1016/j.jvolgeores.2011.06.006

CrossRef Full Text | Google Scholar

Lamb, O. D., De Angelis, S., and Lavallée, Y. (2015). Using infrasound to constrain ash plume rise. J. Appl. Volcanol. 4:20. doi: 10.1186/s13617-015-0038-6

CrossRef Full Text | Google Scholar

Lamb, O. D., Lamur, A., Díaz-Moreno, A., De Angelis, S., Hornby, A. J., von Aulock, F. W., et al. (2019). Disruption of long-term effusive-explosive activity at Santiaguito, Guatemala. Front. Earth Sci. 6:253. doi: 10.3389/feart.2018.00253

CrossRef Full Text | Google Scholar

Landès, M., Ceranna, L., Le Pichon, A., and Matoza, R. S. (2012). Localization of microbarom sources using the IMS infrasound network. J. Geophys. Res. Atmos. 117:D06102. doi: 10.1029/2011JD016684

CrossRef Full Text | Google Scholar

Marchetti, E., Ripepe, M., Ulivieri, G., and Kogelnig, A. (2015). Infrasound array criteria for automatic detection and front velocity estimation of snow avalanches: towards a real-time early-warning system. Nat. Hazards Earth Syst. Sci. 15, 2545–2555. doi: 10.5194/nhess-15-2545-2015

CrossRef Full Text | Google Scholar

Rabiner, L. R., and Gold, B. (1975). Theory and Application of Digital Signal Processing. Englewood Cliffs, NJ: Prentice-Hall, Inc. (1975), 777pp.

Google Scholar

Scarpetta, S., Giudicepietro, F., Ezin, E., Petrosino, S., Del Pezzo, E., Martini, M., et al. (2005). Automatic classification of seismic signals at Mt. Vesuvius volcano, Italy, using neural networks. Bull. Seismol. Soc. Am. 95, 185–196. doi: 10.1785/0120030075

CrossRef Full Text | Google Scholar

Schimmel, A., and Hübl, J. (2016). Automatic detection of debris flows and debris floods based on a combination of infrasound and seismic signals. Landslides 13, 1181–1196. doi: 10.1007/s10346-015-0640-z

CrossRef Full Text | Google Scholar

Vergniolle, S., and Ripepe, M. (2008). From strombolian explosions to fire fountains at Etna volcano (Italy): What do we learn from acoustic measurements? Geol. Soc. Lond. Spec. Publ. 307, 103–124. doi: 10.1144/SP307.7

CrossRef Full Text | Google Scholar

Keywords: volcanic infrasound explosions, automatic detection, signal processing, characteristic function, sub-band processing

Citation: Bueno A, Diaz-Moreno A, Álvarez I, De la Torre A, Lamb OD, Zuccarello L and De Angelis S (2019) VINEDA—Volcanic INfrasound Explosions Detector Algorithm. Front. Earth Sci. 7:335. doi: 10.3389/feart.2019.00335

Received: 18 September 2019; Accepted: 02 December 2019;
Published: 13 December 2019.

Edited by:

Andrea Cannata, University of Catania, Italy

Reviewed by:

John J. Lyons, U.S. Geological Survey, Alaska, United States
Stephen Arrowsmith, Southern Methodist University, United States

Copyright © 2019 Bueno, Diaz-Moreno, Álvarez, De la Torre, Lamb, Zuccarello and De Angelis. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Angel Bueno, angelbueno@ugr.es

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.