Skip to main content

ORIGINAL RESEARCH article

Front. Chem., 08 August 2022
Sec. Green and Sustainable Chemistry
This article is part of the Research Topic Green Chemistry to Recycle Fe/C-rich Wastes for Environmental Pollution Control View all 6 articles

Performance and mechanism of removal of antibiotics and antibiotic resistance genes from wastewater by electrochemical carbon nanotube membranes

Jun Wang,Jun Wang1,2Hong LiuHong Liu1Xiaofei ChenXiaofei Chen3Ye LiYe Li1Xueni ShaXueni Sha1Huanjie SongHuanjie Song1Bolin Li
Bolin Li1*Zheng Yan
Zheng Yan4*Ming Chang
Ming Chang5*
  • 1School of Resource and Environmental Engineering, Wuhan University of Technology, Wuhan, China
  • 2Wuhan Lingang Economic and Technological Development Zone Service Industry Development Investment Group Co. LTD, Wuhan, China
  • 3Hubei Academy of Ecological Environment Sciences, Wuhan, China
  • 4Chinese Society for Environmental Sciences, Beijing, China
  • 5State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Science, Beijing, China

Electrochemical carbon nanotube (CNT) and carboxylated carbon nanotube (CNT-COOH) membranes were prepared by vacuum filtration for the removal of antibiotics and antibiotic resistance genes (ARGs) from water. Scanning electron microscopy and energy-dispersive spectroscopy were used to analyze the performances of the two electrochemical membranes in the removal of antibiotics and ARGs, to determine the effects of different factors on removal rates, and to explore the mechanisms of the removal of antibiotics and ARGs. The results showed that CNT-COOH formed a porous mesh structure on the surface of polytetrafluoroethylene membrane and contained more oxygen than CNT. The electrochemical CNT-COOH membrane showed higher antibiotic and ARG removal rates than the electrochemical CNT membrane, with an antibiotics removal rate of 82% after 60 min of reaction and an ARGs concentration decrease by 1.85 log. The removal rate of antibiotics and ARGs increased with the increase in electrolyte concentration and anode voltage but decreased with the increase in the influent flow rate. The removal rate of antibiotics decreased with the increase in pH, while the best removal rates of ARGs were observed in a neutral environment. The degradation mechanism of antibiotics on the electrochemical CNT-COOH membrane was analyzed, and possible antibiotic degradation pathways were proposed. The removal of antibiotics and ARGs mainly occurred through electrochemical degradation, where hydroxyl radicals (-OH) played a dominant role.

Introduction

Antibiotics are compounds used to treat microbial infectious diseases and have been widely used in the treatment of human and animal diseases, as well as in aquaculture and livestock farming (Manzetti and Ghisi, 2014). The misuse of antibiotics has recently raised public concern. Moreover, during the production and application of antibiotics, large amounts of antibiotic-containing wastewater are produced and discharged into the environment, resulting in serious pollution (Focazio et al., 2008). The residual antibiotics are persistent and difficult to degrade by conventional treatment methods (Kümmerer et al., 2000; Kümmerer, 2009a; Wang and Wang, 2016). Therefore, antibiotics have often been detected in various natural environments (Wang and Wang, 2019) including river water (Huang et al., 2019), groundwater (Szekeres et al., 2018), surface water (Danner et al., 2019), soil (Cerqueira et al., 2019), sediment (Chen and Zhou, 2014), and drinking water (Sanganyado and Gwenzi, 2019). The long-term presence of antibiotics in the natural environment may lead to the generation of antibiotic resistance genes (ARGs) (Dantas et al., 2008) and antibiotic-resistant bacteria (ARB), accelerating the spread of antibiotic resistance, which poses threat to human health and ecosystems (Kümmerer, 2009b).

Membrane technology is considered one of the most promising water treatment methods because of its high separation selectivity, low energy consumption, lack of requirement for additional chemicals, relatively easy scaling, and possibility of continuous operation (Ying et al., 2017; Goh and Ismail, 2018). However, the membrane process also possesses certain drawbacks. During the filtration, the accumulation of contaminants on the membrane surface and inside the membrane pores may lead to membrane fouling through blocking and rejection of the membrane (Miller et al., 2017). Thus, the prolonged use of the membrane may lead to a decrease in its performance (Jhaveri and Murthy, 2016). In addition, membrane separation is a physical process, so although contaminants such as antibiotics may be concentrated, they are not actually broken down, making it difficult to completely remove the contaminants. Electrochemical advanced oxidation process (EAOP) is also an emerging technology that can break down large organic compounds into small molecules that are easily degraded or even mineralize them into CO2, H2O or other inorganic substances. EAOP has attracted increasing attention because of its chemical-free nature, ease of control, stable performance, and environment-friendliness (Chaplin, 2014; Sirés et al., 2014; Martínez-Huitle et al., 2015; Moreira et al., 2017). However, the efficiency of conventional EAOP reactors is usually limited by the weak mass transfer of molecules in the reactor, and EAOP alone is not suitable for the treatment of low-concentration wastewater on a large scale (Ganiyu et al., 2015).

The combination of membrane technology with EAOP may alleviate the membrane contamination issue and resolve the weak mass transfer of EAOP, thus improving the overall separation performance (Yang et al., 2011; Ganiyu et al., 2015; Martínez-Huitle et al., 2015; Li et al., 2018). On the one hand, membrane filtration may be used to concentrate contaminants to the level suitable for EAOP treatment. On the other hand, it confines or retains toxic and hazardous contaminant intermediates in the membrane to degrade or remove the contaminants through reaction with oxidants such as reactive radicals (Molinari et al., 2006).

Membrane filtration is an effective method to remove contaminants from water, and there have been several studies on the removal of micropollutants from water by carbon nanotube (CNT) filtration membranes. Wang et al. (Wang et al., 2018) investigated the removal of acetaminophen, triclosan, caffeine, and carbendazim from water by CNT membrane filtration. Sun et al. (Sun et al., 2020) investigated the removal of tetracycline antibiotics from water by mixed matrix carbon membranes. Wang et al. (Wang et al., 2015) used nanocomposite membranes containing single-walled and multi-walled CNTs to remove triclosan and ibuprofen. Wu et al. (Wu et al., 2016) removed bisphenol A and norfloxacin from drinking water using acid-treated CNTs and polyvinyl chloride ultrafiltration membranes. Guo et al. designed a silicate-enhanced fluidized electro-Fenton system with a nanoconfined catalyst for the removal of tetracycline (Guo et al., 2021). Zheng et al. designed an electrocatalytic filtration system with carbon nanotube supported nanoscale zerovalent copper toward ultrafast oxidation of organic pollutants (Zheng et al., 2021).

In this study, electrochemical CNT and carboxylated CNT (CNT-COOH) membranes for the removal of antibiotics and antibiotic resistance genes (ARGs) from water were prepared by vacuum filtration. The two electrochemical membranes were studied using scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) to explore the effectiveness of the removal of antibiotics and ARGs and factors affecting it. The intermediate products in the degradation of antibiotics were also investigated to explore the mechanism of the removal of antibiotics and ARGs.

Materials and methods

Chemicals and materials

Sodium Sulfate (purity ≥99.5%, analytical grade) was purchased from Sinopharm Chemical Reagent Co. Ltd. The four antibiotics were: sulfamethoxazole (SMX, purity ≥98%, C10H11N3O3S), ofloxacin (OFL, purity ≥98%, C18H20FN3O4), tetracycline (TC, purity ≥98%, C22H24N2O8), and roxithromycin (purity ≥98%, C41H76N2O15), which were purchased from Shanghai Maikelin Biochemical Technology Co. Ltd. The four ARG standards (sul1, tetO, ermA, qnrD) and their primers were purchased from Shanghai Wcgene Biotechnology Co. Ltd. See Supplementary Table S1 for primer names, sequences, corresponding lengths of amplified fragments, and annealing temperatures. Nanotubes and CNT-COOH (w ≥ 95%) were purchased from Chengdu Organic Chemistry Co., Ltd. Chinese Academy of Sciences.

Preparation of electrochemical CNT membranes

CNT and CNT-COOH powders (25 mg) were separately dispersed in low-concentration solutions of surfactant dimethylamide. The prepared CNT and CNT-COOH solutions were sonicated for 30 min and then filtered separately under vacuum at a pressure of 5 KPa. A polytetrafluoroethylene (PTFE) filter membrane with a pore size of 5 μm was used as the substrate. After the filtration was completed, the filter membrane was gently removed from the filtration device, flattened with the pressure of a heavy object, and dried in the air. The dried CNT membrane (CNTM) and CNT-COOH membrane (CNTM-COOH) were then dried in an oven at a constant 100 °C temperature for 2 h; after cooling, they were stored in a cool and dry place for further use. The structural composition of the electrochemical membrane reactor was shown in Figure 1.

FIGURE 1
www.frontiersin.org

FIGURE 1. Schematic of the experimental setup. The electrochemical membrane reactor was designed with a polycarbonate filter casing, which included (1) a perforated titanium cathode, (2) an insulated silicone electrode spacer and seal (0.8 mm), (3) a titanium anode ring pressed onto a CNT anode, and (4) a CNTM/CNTM-COOH anode reactor supported by a PTFE membrane.

Characterization methods

The surface morphology of electrochemical CNT membranes was observed using SEM (SIGMA HD field emission scanning electron microscope, ZEISS, Germany). Elemental microanalysis was performed using EDS (X-Max N80, ZEISS, Germany). The samples were plated with copper prior to qualitative and semi-quantitative elemental analysis of the test locations.

Study on the electrochemical filtration performance of CNT membranes

Antibiotic mixture solution with a concentration of 0.25 mg/L and ARGs mixture solution of 1 × 109 copies/mL were prepared. The differences in the removal performance of the electrochemical CNTM and CNTM-COOH were evaluated by using them as anodes of the electrochemical membrane reactor.

The effects of the following experimental parameters: electrolyte (Na2SO4) concentration (0.001, 0.01, and 0.1 mol/L), voltage (0, 1.0, 2.0, and 3.0 V), flow rate (5, 10, and 15 ml/min), and pH (3, 5, 7, 9, and 11) on the filtration performance were investigated.

Wastewater containing antibiotics and ARGs was fed from the inlet container through a peristaltic pump to the water inlet at the upper end of the reactor casing and flowed out the lower outlet after passing through the electrochemical CNT membrane reactor. Water samples were taken periodically at the outlet to determine the concentration of antibiotics and ARGs in the effluent.

Analysis methods

Antibiotics were detected using high-performance liquid chromatography (HPLC). The analytical column used for antibiotic detection was ACQUITY UPLC BEH C18 (2.1 × 100 mm, l.7 μm; Waters, United States). The mobile phases were 0.1% formic acid in ultrapure water (v/v) and 0.1% formic acid in acetonitrile. The sample injection volume was set to 5 μL, and the gradient elution mode was selected, and the elution procedure is shown in Supplementary Table S2. Determination of intermediate products of antibiotics degradation by high performance liquid chromatography tandem quadrupole time-of-flight mass spectrometry (Q-ToF-MS). Mass spectrometry was performed using an electrospray ionization source in positive ion mode (ESI+) and multiple reaction detection mode. The capillary voltage was 3.0 kV, the cone voltage was set to 6–100 V, and the ion source temperature was set to 150°C. The temperature of the desolvation gas (N2) was set to 550°C, and the flow rate of the desolvation gas was 1000 L/h. The flow rate of the cone gas (N2) was 50 L/h, the flow rate of the impingement gas (Ar) was set to 0.15 ml/min, and the column temperature was 40°C.

DNA was extracted using the PowerSoil DNA Isolation kit, and the extracted DNA samples were stored at -20°C until subsequent gene quantification assays. PCR amplification, as well as quantification of ARGs, was performed by using quantitative PRC (qPCR). qPCR was performed using a fluorescent quantitative PCR instrument (qTower2.2, Jena, Germany).

The removal rate of antibiotics was calculated using Equation 1.

R(%)=(C(in)C(out))/C(in)(1)

The removal rate of ARGs was calculated using Equation 2.

RARGs=Log C(in)Log C(out)(2)

where RARGs is the logarithm (log) of the removal rate of ARGs by the reactor. C(in) and C(out) are the pollutant concentrations in the influent and effluent, respectively.

Results and discussion

Characterization of electrochemical CNT membranes

It can be seen from Figure 2A that the conventional CNTs are entangled and agglomerated in lumps, which could not be well dispersed even after ultrasonication. Compared with CNT, CNT-COOH is less prone to agglomeration better dispersion, its surface is smoother, the truncated surface is more obvious, and it can maintain a larger dispersion. From Figure 2B, the surface of CNTM-COOH is clean and more uniform than that of CNTM, and the three-dimensional network structure formed by individual CNTs and the intertwining of CNTs could be clearly observed, with gaps of different sizes between individual nanotubes. This indicated that after vacuum filtration, CNT-COOH covered the surface of the PTFE membrane uniformly and formed a porous mesh structure on the surface of the PTFE membrane. In addition, it has been shown that CNT can produce more defective sites and polar groups, such as carboxyl groups, after acidification, and it is these introduced oxygen-containing groups that improve its dispersibility.

FIGURE 2
www.frontiersin.org

FIGURE 2. (A)(B) SEM and (C)(D) EDS characterization images and (E)(F) performance of CNTM and CNTM-COOH.

The contents of C and O in the two different CNT types are shown in Figure 2C below. The content of C in CNT was 95.70%, and that of O was 0.37%; From Figure 2D, the weight percentages of C and O in CNT-COOH were 94.44% and 0.93%, respectively, which showed that CNT-COOH contained more oxygen-containing groups. This may be attributed to the introduction of O on the surface of CNT-COOH by the strong acid during carboxylation.

Comparison of the removal performance of electrochemical CNT membranes

The anode voltage was set to 1 V, the flow rate was set to 10 ml/min, and the concentration of electrolyte Na2SO4 was set to 0.01 mol/L to treat antibiotics and ARGs with concentrations of 0.25 mg/L and 1 × 109 copies/mL The results are shown in Figures 2E,F.

Since the reactor is operated in a vertical flow mode, the influent concentration is constant (without considering the hydrolysis of antibiotics and ARGs) and the effluent water is not returned to the reactor, so the effluent concentration should remain stable after a period of reactor operation due to the continuous oxidation reaction on the carbon nanotube membrane electrodes to degrade pollutants. The removal of antibiotics by the electrochemical CNTM reactor was approximately 72% after 60 min of operation, and the concentration of ARGs decreased by 1.1 log. After 60 min of operation of the electrochemical CNTM-COOH reactor, the removal of antibiotics by the reactor was as high as 82%, and the ARG concentration decreased by approximately 1.85 log, with stable removal capacity and a removal efficiency higher than that of CNTM. This may be attributed to the better dispersion of CNTM-COOH after carboxylation and higher oxygen-containing group content of CNTM-COOH. In addition, more defects and active sites were created during the acidification (Gao et al., 2015), which gave CNTM-COOH higher oxygen evolution potential and therefore better electrochemical oxidation properties.

Effect of electrolyte concentration

The removal of the antibiotics and ARGs by the electrochemical CNT membrane reactor at different concentrations (0.001, 0.01, and 0.1 mol/L) of electrolyte (Na2SO4) are shown in Figures 3A,B. With the increase in Na2SO4 concentration, the concentrations of antibiotics and ARGs in the reactor effluent gradually decreased, which was attributed to the increased electrolysis efficiency because with increasing electrolyte concentration, the conductivity of the reaction system also increased. However, the effect of Na2SO4 concentration on the oxidative degradation of antibiotics and ARGs was limited. When the Na2SO4 concentration was increased from 0.01 to 0.1 mol/L, the changes in the concentrations of antibiotics and ARGs in the effluent were not significant despite a 10-fold increase in electrolyte concentration. This may be explained by the migration of SO42- to the anode to occupy the active site on the anode at high Na2SO4 concentrations, thus reducing the removal rate. Yang et al. (Yang et al., 2020) found in the study on the degradation of 4-epi-anhydrochlotetracycline that excessive SO42- occupied the active sites on the electrode. Chen et al. (Chen et al., 2015) and Zhong et al. (Zhong et al., 2013) also reported that at high Na2SO4 concentrations, more SO42- migrated to the anode to occupy the active sites on the anode, thus reducing the removal efficiency.

FIGURE 3
www.frontiersin.org

FIGURE 3. Effect of (A)(B) electrolyte concentration (C)(D) anode voltage (E)(F) flow rate and (G)(H) pH on the degradation of antibiotics and ARGs by the electrochemical CNTM-COOH reactor.

Effect of anode voltage

The removal rates of antibiotics and ARGs by the electrochemical CNT membrane reactor at different voltages (0, 1.0, 2.0, and 3.0 V) are shown in Figures 3C,D. It can be seen from Figure 3C that the removal rate of antibiotics at 1 V is almost the same as that at 0 V, while at 2 and 3 V, the removal rates of antibiotics reach 80 and 90%, respectively. The slight increase in the removal effect at 1 V compared to 0 V may be explained by electrostatic adsorption (Sun et al., 2020). Figure 3D shows that the concentration of ARGs only decreased by approximately 0.4–0.5 log at a voltage of 0 V. ARGs may be removed mainly through adsorption. However, the concentration decreased by 2.2–2.3 log at voltages of 2 and 3 V. Significant degradation of antibiotics and ARGs at 2 and 3 V may be attributed to the increase in the number of electrons generated with the increase in voltage, which increased the content of hydroxyl radicals as well as improved the removal of pollutants (Liu and Vecitis, 2012). However, too high anode potential may also lead to water-resolving oxygen reactions, and there is direct competition between organic oxidation and oxygen precipitation reactions. In addition, the high anode potential may damage the structure of carbon nanotubes, which is not conducive to the normal and stable operation of the carbon nanotube electrochemical membrane reactor. Therefore, the optimal anode voltage was chosen to be 2.0 V for the experiment.

Effect of inlet water flow

The removal rates of antibiotics and ARGs by the electrochemical CNT membrane reactor at different flow rates (5, 10, and 15 ml/min) are shown in Figures 3E,F. The removal rates for antibiotics and ARGs decreased with the increase in the flow rate. The lowest antibiotic concentration in the effluent was observed at the flow rate of 5 ml/min. This may be explained by the low flow rate resulting in an increase in retention time, which significantly prolonged the degradation time of different pollutants and their intermediates, resulting in their fuller degradation (Cui et al., 2009). However, the volume of antibiotic wastewater treated per unit time was also lower at lower flow rates. In a study by Liu et al. (Liu et al., 2016), the efficiency of antibiotics removal by electrochemical membranes increased with the decrease in flow rate. The lower the flow rate, the longer the retention time, and the more complete the degradation of TC. This was attributed to the longer duration of the contact between the pollutants and electrodes causing the reaction to proceed to greater completion. However, when the influent flow rate was too small and the retention time was too long, especially when exceeding 4.4 min, the degradation of TC by the electrochemical membrane became less effective. This was because the liquid mass transfer efficiency in the reactor became low owing to the prolonged retention time.

Effect of solution pH

The removal of antibiotics and ARGs by the electrochemical CNT membrane reactor at different pH (pH = 3, 5, 7, 9, and 11) is shown in Figures 3G,H. Figure 3G shows that the maximum removal of antibiotics was 95.6% at a pH of 3, and the lowest removal of antibiotics was 75.5% at a pH of 11. The different removal rates at different pH values may be attributed to the fact that antibiotics have different morphology at different pH levels (Gao et al., 2014), thereby affecting the degradation mechanism and the removal rate (Fan et al., 2016). On the one hand, acidic conditions may have accelerated the hydrolysis of antibiotic molecules in the aqueous solution (Sopaj et al., 2020). On the other hand, H+ in acidic conditions facilitated the production of -OH, strong oxidizing properties of which played an important role in the degradation of antibiotics, and that H2O2 decomposes to O2 under basic conditions (Liu et al., 2020). Therefore, the removal rate of antibiotics under acidic conditions was higher. Figure 3H shows that the removal rate of ARGs increased with increasing pH in the range of 1–7 but decreased with increasing pH above 7. The concentration of ARGs decreased by 2.30 log at a pH of 7. At the pH below 7, the phosphate groups on ARGs tended to be positively charged by protonation, and the increase in surface charge led to repulsion between the positively charged CNTM-COOH (pH = 1–3) and the protonated phosphate groups in ARGs (Vecitis et al., 2011), which led to a decrease in the ARGs removal rate. At the pH exceeding 7, ARGs became deprotonated and negatively charged, and interacted with the cations in the solution (e.g., Na+ ions), which disrupted the structure and surface charge of ARGs. This affected the interaction between ARGs and the electrochemical CNT membrane and reduced the mass transfer, resulting in a decrease in the removal rate (Vecitis et al., 2011).

Intermediate products and degradation pathways

Liquid chromatography coupled with mass spectrometry was used to further identify the intermediate products to elucidate the effects of -OH, which was generated during the electrochemical process, on the oxidative degradation of antibiotics. OFL and SMX were selected as study objects to propose reasonable speculations on the degradation pathways of antibiotics based on the intermediates detected during degradation based on the results of previous studies. The structural information for OFL and SMX is shown in Supplementary Figures S1, S2.

The intermediates of OFL during the electrochemical degradation were identified using HPLC-Q-TOF-MS/MS, and four major intermediates with mass-to-charge ratios (m/z) of 378, 336, 348, and 294 were ultimately detected. The molecular structures and other information on these four compounds are provided in Supplementary Table S5, and the mass spectral data are shown in Supplementary Figures S3, S4.

The substituent of the piperazine ring of OFL was changed in the electrochemical oxidative degradation system, in which the piperazine ring was first hydroxylated to generate product P378 (m/z = 378), which was subsequently dehydrated to generate product P360 (m/z = 360). The methyl group on the piperazine ring was removed to generate product P348 (m/z = 348). Both the piperazine and oxazine rings of OFL were opened to generate product S294 (m/z = 294) (Gong et al., 2016), and the removal of the ethyl group at N1 or the methyl group at N4 on the piperazine ring produced P336 (m/z = 336).

Based on the results of the intermediate product analysis, the proposed degradation pathway of OFL is shown in Figure 4A. The degradation of OFL consisted of two oxidation pathways, namely the demethylation reaction and the hydroxylation and decarboxylation of piperazine. Pathway I: the piperazine ring of OFL was attacked by hydroxyl radicals to produce a mono-hydroxyl derivative, namely the degradation product P378, in which a water molecule was then removed to generate product P360. Pathway II: degradation product S294 was generated through the removal of the ethyl group at N1 or the methyl group at N4 on the piperazine ring of the OFL molecule, followed by decarboxylation to remove methyl and carboxyl groups. Ultimately, the intermediate products mentioned above underwent oxidation to produce CO2 and H2O (Wang et al., 2022).

FIGURE 4
www.frontiersin.org

FIGURE 4. Proposed degradation pathway and mechanisms of antibiotics. (A) OFL (B) SMX (C) Influence of TBA and BQ on the electrochemical oxidation of antibiotics.

The intermediates of SMX during electrochemical degradation were identified using the HPLC-Q-TOF-MS/MS, and two major intermediate products with mass-to-charge ratios (m/z) of 284 and 299 were detected. The information such as molecular structures are provided in Supplementary Table S6, and the MS data for these two compounds are shown in Supplementary Figure S5.

Based on the results of the analysis of intermediates, the tentative degradation pathway of SMX is shown in Figure 4B. The actual detected compounds were labeled as “P”, while other intermediates postulated based on previous studies (Wang and Wang, 2018; Yin et al., 2019; Wang et al., 2020) were noted with dashed rectangles and labeled as “S". The degradation was presumed to be mainly occur through the oxidation of the phenylamine group into nitro-SMX derivatives, and similar results were obtained by Wang et al. (Wang and Wang, 2018).

In the above pathway, the phenylamine group is oxidized by -OH to produce nitro-SMX derivatives. This may be attributed to the fact that the rapid hydration of N-centered radicals formed aniline radicals, which were further neutralized by oxidation, leading to the hydrolysis of hydroxylamine and nitroso derivatives to produce nitro-SMX (Wang et al., 2020). Subsequently, -OH attacked the benzene ring to generate S140 and S179, and then the S-N single bond was attacked by -OH, leading to the breakage of the sulfonamide bond and the generation of S99. Through the successive hydroxylation of these primary products and by-products, SMX may eventually be mineralized to CO2, H2O, SO42-, and NO3. These reaction pathways were consistent with the findings of previous studies on SMX degradation, particularly on SMX degradation using Ti/SnO2-Sb/Ce-PbO2 anode (Liu et al., 2013) and photocatalysis (Su et al., 2016).

Smaller intermediate molecules were not detected in this study, but previous studies have demonstrated the generation of small organic molecules, such as aniline, 1,4-benzoquinone, as well as several derivatives such as aromatic sulfonamides (Yin et al., 2019; Wang et al., 2020). Aliphatic intermediates produced during electrolysis were eventually mineralized into CO2 and H2O (Dirany et al., 2010; Amina et al., 2018).

Mechanisms of electrochemical oxidative degradation

The mechanism of electrochemical oxidative degradation reaction follows a multi-step process: firstly, deposition and adsorption of antibiotics on the electrode surface, secondly, degradation and molecular transformation of antibiotics, and finally, flaking of degradation products (Tan et al., 2020). Direct oxidation is the oxidation of the antibiotic attached to the CNT electrochemical membrane reactor, which is an electronic process. Indirect oxidation has two steps, the first step is the generation of some dissolved free radicals on the anode. The second step is the stepwise oxidation of the antibiotic by the generated oxidant (Liu et al., 2020). To determine the effect of the indirect oxidation pathways on the electrochemical oxidation of antibiotics on CNT electrodes, tert-butanol (TBA) and benzoquinone (BQ) were added to the simulated aqueous solutions of antibiotics, respectively, to capture the -OH and O2 radicals that may be produced during degradation to identify the main radical groups that affected the degradation of antibiotics. The experimental results are shown in Figure 4C. The addition of both TBA and BQ resulted in lower removal rates of antibiotics. The removal rate of antibiotics in the TBA group was lower than that in the BQ group, which indicated that -OH plays a dominant role and -O2- plays a secondary role in the indirect oxidative degradation of antibiotics and ARGs on electrochemical CNT membranes.

Conclusion

A three-dimensional network structure was observed on the surface of the electrochemical CNTM-COOH, which had more oxygen-containing groups after carboxylation treatment, making them more effective in removing the antibiotics and ARGs than conventional electrochemical CNTMs.

The removal rates of antibiotics and ARGs increased with the increase in electrolyte concentration and anode voltage but decreased with the increase in the influent flow rate. pH mainly affected the removal through influencing the state of antibiotics and ARGs. The removal rate of antibiotics decreased with the increase in pH, with the best removal effect of ARGs obtained in a neutral environment.

The hydroxylation of SMX and ring opening reactions of benzene were the main degradation pathways of SMX, and the degradation of OFL mainly occurred via the piperazine ring. In the removal of antibiotics by electrochemical CNT membranes -OH played a primary role and -O2- played a secondary role.

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding authors.

Author contributions

JW: Funding acquisition, resources, conceptualization, methodology, writing—original draft, writing—review and editing. HL: Methodology, investigation, data curation, visualization, formal analysis, writing—original draft. XC and YL: Supervision, Funding acquisition. XS: Investigation, formal analysis. HS: Investigation. BL, ZY and MC: Project administration, conceptualization, methodology, data curation, formal analysis, writing—review and editing.

Funding

This study was financially supported by Wuhan City Applied Basic Frontier Project (Grant No. 2018060401011313), National Key Research and Development Program (2019YFC0408602, 2020YFC1806302).

Conflict of interest

Author JW is employed by Wuhan Lingang Economic and Technological Development Zone Service Industry Development Investment Group Co. LTD. China.

The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fchem.2022.973490/full#supplementary-material

References

AminaSi, X., Wu, K., Si, Y., and Yousaf, B. (2018). Synergistic effects and mechanisms of hydroxyl radical-mediated oxidative degradation of sulfamethoxazole by Fe (II)-EDTA catalyzed calcium peroxide: Implications for remediation of antibiotic-contaminated water. Chem. Eng. J. 353, 80–91. doi:10.1016/j.cej.2018.07.078

CrossRef Full Text | Google Scholar

Cerqueira, F., Matamoros, V., Bayona, J., Elsinga, G., Hornstra, L. M., and Piña, B. (2019). Distribution of antibiotic resistance genes in soils and crops. A field study in legume plants (vicia faba L.) grown under different watering regimes. Environ. Res. 170, 16–25. doi:10.1016/j.envres.2018.12.007

PubMed Abstract | CrossRef Full Text | Google Scholar

Chaplin, B. P. (2014). Critical review of electrochemical advanced oxidation processes for water treatment applications. Environ. Sci. Process. Impacts 16, 1182–1203. doi:10.1039/c3em00679d

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, J., Xia, Y., and Dai, Q. (2015). Electrochemical degradation of chloramphenicol with a novel Al doped PbO2 electrode: Performance, kinetics and degradation mechanism. Electrochim. Acta 165, 277–287. doi:10.1016/j.electacta.2015.02.029

CrossRef Full Text | Google Scholar

Chen, K., and Zhou, J. L. (2014). Occurrence and behavior of antibiotics in water and sediments from the huangpu river, Shanghai, China. Chemosphere Oxf. 95, 604–612. doi:10.1016/j.chemosphere.2013.09.119

PubMed Abstract | CrossRef Full Text | Google Scholar

Cui, Y., Li, X., and Chen, G. (2009). Electrochemical degradation of bisphenol A on different anodes. Water Res. 43, 1968–1976. doi:10.1016/j.watres.2009.01.026

PubMed Abstract | CrossRef Full Text | Google Scholar

Danner, M., Robertson, A., Behrends, V., and Reiss, J. (2019). Antibiotic pollution in surface fresh waters: Occurrence and effects. Sci. Total Environ. 664, 793–804. doi:10.1016/j.scitotenv.2019.01.406

PubMed Abstract | CrossRef Full Text | Google Scholar

Dantas, G., Sommer, M. O. A., Oluwasegun, R. D., and Church, G. M. (2008). Bacteria subsisting on antibiotics. Science 320, 100–103. doi:10.1126/science.1155157

PubMed Abstract | CrossRef Full Text | Google Scholar

Dirany, A., Sirés, I., Oturan, N., and Oturan, M. A. (2010). Electrochemical abatement of the antibiotic sulfamethoxazole from water. Chemosphere 81, 594–602. doi:10.1016/j.chemosphere.2010.08.032

PubMed Abstract | CrossRef Full Text | Google Scholar

Fan, X., Zhao, H., Quan, X., Liu, Y., and Chen, S. (2016). Nanocarbon-based membrane filtration integrated with electric field driving for effective membrane fouling mitigation. Water Res. 88, 285–292. doi:10.1016/j.watres.2015.10.043

PubMed Abstract | CrossRef Full Text | Google Scholar

Focazio, M. J., Kolpin, D. W., Barnes, K. K., Furlong, E. T., Meyer, M. T., Zaugg, S. D., et al. (2008). A national reconnaissance for pharmaceuticals and other organic wastewater contaminants in the United States — II) untreated drinking water sources. Sci. Total Environ. 402, 201–216. doi:10.1016/j.scitotenv.2008.02.021

PubMed Abstract | CrossRef Full Text | Google Scholar

Ganiyu, S. O., van Hullebusch, E. D., Cretin, M., Esposito, G., and Oturan, M. A. (2015). Coupling of membrane filtration and advanced oxidation processes for removal of pharmaceutical residues: A critical review. Sep. Purif. Technol. 156, 891–914. doi:10.1016/j.seppur.2015.09.059

CrossRef Full Text | Google Scholar

Gao, G., Pan, M., and Vecitis, C. D. (2015). Effect of the oxidation approach on carbon nanotube surface functional groups and electrooxidative filtration performance. J. Mat. Chem. A 3, 7575–7582. doi:10.1039/C4TA07191C

CrossRef Full Text | Google Scholar

Gao, G., Zhang, Q., and Vecitis, C. D. (2014). CNT–PVDF composite flow-through electrode for single-pass sequential reduction–oxidation. J. Mat. Chem. A 2, 6185. doi:10.1039/c3ta14080f

CrossRef Full Text | Google Scholar

Goh, P. S., and Ismail, A. F. (2018). A review on inorganic membranes for desalination and wastewater treatment. Desalination 434, 60–80. doi:10.1016/j.desal.2017.07.023

CrossRef Full Text | Google Scholar

Gong, Y., Li, J., Zhang, Y., Zhang, M., Tian, X., Wang, A., et al. (2016). Partial degradation of levofloxacin for biodegradability improvement by electro-fenton process using an activated carbon fiber felt cathode. J. Hazard. Mat. 304, 320–328. doi:10.1016/j.jhazmat.2015.10.064

PubMed Abstract | CrossRef Full Text | Google Scholar

Guo, D., Liu, Y., Ji, H., Wang, C., Chen, B., Shen, C., et al. (2021). Silicate-enhanced heterogeneous flow-through electro-fenton system using iron oxides under nanoconfinement. Environ. Sci. Technol. 55, 4045–4053. doi:10.1021/acs.est.1c00349

PubMed Abstract | CrossRef Full Text | Google Scholar

Huang, Y., Liu, Y., Du, P., Zeng, L., Mo, C., Li, Y., et al. (2019). Occurrence and distribution of antibiotics and antibiotic resistant genes in water and sediments of urban rivers with black-odor water in guangzhou, south China. Sci. Total Environ. 670, 170–180. doi:10.1016/j.scitotenv.2019.03.168

PubMed Abstract | CrossRef Full Text | Google Scholar

Jhaveri, J. H., and Murthy, Z. V. P. (2016). A comprehensive review on anti-fouling nanocomposite membranes for pressure driven membrane separation processes. Desalination 379, 137–154. doi:10.1016/j.desal.2015.11.009

CrossRef Full Text | Google Scholar

Kümmerer, K., Al-Ahmad, A., and Mersch-Sundermann, V. (2000). Biodegradability of some antibiotics, elimination of the genotoxicity and affection of wastewater bacteria in a simple test. Chemosphere 40, 701–710. doi:10.1016/S0045-6535(99)00439-7

PubMed Abstract | CrossRef Full Text | Google Scholar

Kümmerer, K. (2009b). Antibiotics in the aquatic environment – A review – Part I. Chemosphere 75, 417–434. doi:10.1016/j.chemosphere.2008.11.086

CrossRef Full Text | Google Scholar

Kümmerer, K. (2009a). Antibiotics in the aquatic environment – A review – Part II. Chemosphere 75, 435–441. doi:10.1016/j.chemosphere.2008.12.006

CrossRef Full Text | Google Scholar

Li, C., Zhang, M., Song, C., Tao, P., Sun, M., Shao, M., et al. (2018). Enhanced treatment ability of membrane technology by integrating an electric field for dye wastewater treatment: A review. J. Aoac Int. 101, 1341–1352. doi:10.5740/jaoacint.18-0050

PubMed Abstract | CrossRef Full Text | Google Scholar

Liu, F., Liu, Y., Yao, Q., Wang, Y., Fang, X., Shen, C., et al. (2020). Supported atomically-precise gold nanoclusters for enhanced flow-through electro-fenton. Environ. Sci. Technol. 54, 5913–5921. doi:10.1021/acs.est.0c00427

PubMed Abstract | CrossRef Full Text | Google Scholar

Liu, H., Vajpayee, A., and Vecitis, C. D. (2013). Bismuth-doped tin oxide-coated carbon nanotube network: Improved anode stability and efficiency for flow-through organic electrooxidation. ACS Appl. Mat. Interfaces 5, 10054–10066. doi:10.1021/am402621v

CrossRef Full Text | Google Scholar

Liu, H., and Vecitis, C. D. (2012). Reactive transport mechanism for organic oxidation during electrochemical filtration: Mass-transfer, physical adsorption, and electron-transfer. J. Phys. Chem. C 116, 374–383. doi:10.1021/jp209390b

CrossRef Full Text | Google Scholar

Liu, Z., Zhu, M., Wang, Z., Wang, H., Deng, C., Li, K., et al. (2016). Effective degradation of aqueous tetracycline using a nano-TiO2/carbon electrocatalytic membrane. Materials 9, 364. doi:10.3390/ma9050364

PubMed Abstract | CrossRef Full Text | Google Scholar

Manzetti, S., and Ghisi, R. (2014). The environmental release and fate of antibiotics. Mar. Pollut. Bull. 79, 7–15. doi:10.1016/j.marpolbul.2014.01.005

PubMed Abstract | CrossRef Full Text | Google Scholar

Martínez-Huitle, C. A., Rodrigo, M. A., Sirés, I., and Scialdone, O. (2015). Single and coupled electrochemical processes and reactors for the abatement of organic water pollutants: A critical review. Chem. Rev. 115, 13362–13407. doi:10.1021/acs.chemrev.5b00361

PubMed Abstract | CrossRef Full Text | Google Scholar

Miller, D. J., Dreyer, D. R., Bielawski, C. W., Paul, D. R., and Freeman, B. D. (2017). Surface modification of water purification membranes. Angew. Chem. Int. Ed. 56, 4662–4711. doi:10.1002/anie.201601509

CrossRef Full Text | Google Scholar

Molinari, R., Pirillo, F., Loddo, V., and Palmisano, L. (2006). Heterogeneous photocatalytic degradation of pharmaceuticals in water by using polycrystalline TiO2 and a nanofiltration membrane reactor. Catal. Today 118, 205–213. doi:10.1016/j.cattod.2005.11.091

CrossRef Full Text | Google Scholar

Moreira, F. C., Boaventura, R. A. R., Brillas, E., and Vilar, V. J. P. (2017). Electrochemical advanced oxidation processes: A review on their application to synthetic and real wastewaters. Appl. Catal. B Environ. 202, 217–261. doi:10.1016/j.apcatb.2016.08.037

CrossRef Full Text | Google Scholar

Sanganyado, E., and Gwenzi, W. (2019). Antibiotic resistance in drinking water systems: Occurrence, removal, and human health risks. Sci. Total Environ. 669, 785–797. doi:10.1016/j.scitotenv.2019.03.162

PubMed Abstract | CrossRef Full Text | Google Scholar

Sirés, I., Brillas, E., Oturan, M. A., Rodrigo, M. A., and Panizza, M. (2014). Electrochemical advanced oxidation processes: Today and tomorrow. A review. Environ. Sci. Pollut. Res. 21, 8336–8367. doi:10.1007/s11356-014-2783-1

CrossRef Full Text | Google Scholar

Sopaj, F., Oturan, N., Pinson, J., Podvorica, F. I., and Oturan, M. A. (2020). Effect of cathode material on electro-fenton process efficiency for electrocatalytic mineralization of the antibiotic sulfamethazine. Chem. Eng. J. 384, 123249. doi:10.1016/j.cej.2019.123249

CrossRef Full Text | Google Scholar

Su, Y., Wang, G., Kuo, D. T. F., Chang, M., and Shih, Y. (2016). Photoelectrocatalytic degradation of the antibiotic sulfamethoxazole using TiO2/Ti photoanode. Appl. Catal. B Environ. 186, 184–192. doi:10.1016/j.apcatb.2016.01.003

CrossRef Full Text | Google Scholar

Sun, M., Cui, M., Wang, Y., Fan, X., and Song, C. (2020). Enhanced permeability and removal efficiency for phenol and perfluorooctane sulphonate by a multifunctional CNT/Al2O3 membrane with electrochemical assistance. J. Nanosci. Nanotechnol. 20, 5951–5958. doi:10.1166/jnn.2020.18554

PubMed Abstract | CrossRef Full Text | Google Scholar

Szekeres, E., Chiriac, C. M., Baricz, A., Szőke-Nagy, T., Lung, I., Soran, M., et al. (2018). Investigating antibiotics, antibiotic resistance genes, and microbial contaminants in groundwater in relation to the proximity of urban areas. Environ. Pollut. 236, 734–744. doi:10.1016/j.envpol.2018.01.107

PubMed Abstract | CrossRef Full Text | Google Scholar

Tan, T., Zeng, Z., Zeng, G., Gong, J., Xiao, R., Zhang, P., et al. (2020). Electrochemically enhanced simultaneous degradation of sulfamethoxazole, ciprofloxacin and amoxicillin from aqueous solution by multi-walled carbon nanotube filter. Sep. Purif. Technol. 235, 116167. doi:10.1016/j.seppur.2019.116167

CrossRef Full Text | Google Scholar

Vecitis, C. D., Schnoor, M. H., Rahaman, M. S., Schiffman, J. D., and Elimelech, M. (2011). Electrochemical multiwalled carbon nanotube filter for viral and bacterial removal and inactivation. Environ. Sci. Technol. 45, 3672–3679. doi:10.1021/es2000062

PubMed Abstract | CrossRef Full Text | Google Scholar

Wang, F., Chen, Z., Zhu, Z., and Guo, J. (2022). Construction of visible light responsive ZnO/N-g-C3N4 composite membranes for antibiotics degradation. J. Mater. Res. Technol. 17, 1696–1706. doi:10.1016/j.jmrt.2022.01.140

CrossRef Full Text | Google Scholar

Wang, J., and Wang, S. (2019). Preparation, modification and environmental application of biochar: A review. J. Clean. Prod. 227, 1002–1022. doi:10.1016/j.jclepro.2019.04.282

CrossRef Full Text | Google Scholar

Wang, J., and Wang, S. (2016). Removal of pharmaceuticals and personal care products (PPCPs) from wastewater: A review. J. Environ. Manage. 182, 620–640. doi:10.1016/j.jenvman.2016.07.049

PubMed Abstract | CrossRef Full Text | Google Scholar

Wang, S., and Wang, J. (2018). Radiation-induced degradation of sulfamethoxazole in the presence of various inorganic anions. Chem. Eng. J. 351, 688–696. doi:10.1016/j.cej.2018.06.137

CrossRef Full Text | Google Scholar

Wang, S., Xu, W., Wu, J., Gong, Q., and Xie, P. (2020). Improved sulfamethoxazole degradation by the addition of MoS2 into the Fe2+/peroxymonosulfate process. Sep. Purif. Technol. 235, 116170. doi:10.1016/j.seppur.2019.116170

CrossRef Full Text | Google Scholar

Wang, Y., Huang, H., and Wei, X. (20181996). Influence of wastewater precoagulation on adsorptive filtration of pharmaceutical and personal care products by carbon nanotube membranes. Chem. Eng. J. 333, 66–75. doi:10.1016/j.cej.2017.09.149

CrossRef Full Text | Google Scholar

Wang, Y., Zhu, J., Huang, H., and Cho, H. (2015). Carbon nanotube composite membranes for microfiltration of pharmaceuticals and personal care products: Capabilities and potential mechanisms. J. Memb. Sci. 479, 165–174. doi:10.1016/j.memsci.2015.01.034

CrossRef Full Text | Google Scholar

Wu, H., Niu, X., Yang, J., Wang, C., and Lu, M. (2016). Retentions of bisphenol A and norfloxacin by three different ultrafiltration membranes in regard to drinking water treatment. Chem. Eng. J. 294, 410–416. doi:10.1016/j.cej.2016.02.117

CrossRef Full Text | Google Scholar

Yang, S., Liu, Y., Shen, C., Li, F., Yang, B., Huang, M., et al. (2020). Rapid decontamination of tetracycline hydrolysis product using electrochemical CNT filter: Mechanism, impacting factors and pathways. Chemosphere 244, 125525. doi:10.1016/j.chemosphere.2019.125525

PubMed Abstract | CrossRef Full Text | Google Scholar

Yang, Y., Li, J., Wang, H., Song, X., Wang, T., He, B., et al. (2011). An electrocatalytic membrane reactor with self-cleaning function for industrial wastewater treatment. Angew. Chem. Int. Ed. 50, 2148–2150. doi:10.1002/anie.201005941

CrossRef Full Text | Google Scholar

Yin, R., Guo, W., Wang, H., Du, J., Wu, Q., Chang, J., et al. (2019). Singlet oxygen-dominated peroxydisulfate activation by sludge-derived biochar for sulfamethoxazole degradation through a nonradical oxidation pathway: Performance and mechanism. Chem. Eng. J. 357, 589–599. doi:10.1016/j.cej.2018.09.184

CrossRef Full Text | Google Scholar

Ying, Y., Ying, W., Li, Q., Meng, D., Ren, G., Yan, R., et al. (2017). Recent advances of nanomaterial-based membrane for water purification. Appl. Mater. today 7, 144–158. doi:10.1016/j.apmt.2017.02.010

CrossRef Full Text | Google Scholar

Zheng, W., Liu, Y., Liu, W., Ji, H., Li, F., Shen, C., et al. (2021). A novel electrocatalytic filtration system with carbon nanotube supported nanoscale zerovalent copper toward ultrafast oxidation of organic pollutants. Water Res. 194, 116961. doi:10.1016/j.watres.2021.116961

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhong, C., Wei, K., Han, W., Wang, L., Sun, X., Li, J., et al. (2013). Electrochemical degradation of tricyclazole in aqueous solution using Ti/SnO2–Sb/PbO2 anode. J. Electroanal. Chem. (Lausanne). 705, 68–74. doi:10.1016/j.jelechem.2013.07.027

CrossRef Full Text | Google Scholar

Keywords: carbon nanotubes, antibiotics, antibiotic resistance genes, removal mechanism, electrochemical oxidation

Citation: Wang J, Liu H, Chen X, Li Y, Sha X, Song H, Li B, Yan Z and Chang M (2022) Performance and mechanism of removal of antibiotics and antibiotic resistance genes from wastewater by electrochemical carbon nanotube membranes. Front. Chem. 10:973490. doi: 10.3389/fchem.2022.973490

Received: 20 June 2022; Accepted: 07 July 2022;
Published: 08 August 2022.

Edited by:

Zhu Suiyi, Northeast Normal University, China

Reviewed by:

Wenbing Tan, Chinese Research Academy of Environmental Sciences, China
Yanbiao Liu, Donghua University, China

Copyright © 2022 Wang, Liu, Chen, Li, Sha, Song, Li, Yan and Chang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Bolin Li, Ym9sbHkxMjIxQHdodXQuZWR1LmNu; Zheng Yan, Mzc3NTQ1OTBAcXEuY29t; Ming Chang, Y2hhbmdtaW5nQGNyYWVzLm9yZy5jbg==

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.