ORIGINAL RESEARCH article

Front. Cardiovasc. Med., 23 November 2023
Sec. Cardiac Rhythmology
This article is part of the Research Topic Insights in Cardiac Rhythmology: 2023 View all 13 articles

A simplified single transseptal puncture approach using high-density 3D voltage mapping for atrial fibrillation ablation: acute complications and long-term results

\r\nPedro Silva Cunha,,,,
&#x;,&#x;Pedro Silva Cunha1,2,3,4,5*†,‡Brbara Lacerda Teixeira,,&#x;Bárbara Lacerda Teixeira1,2,†Srgio Laranjo,,Sérgio Laranjo1,5,6Guilherme Portugal,,Guilherme Portugal1,2,3Bruno Valente,Bruno Valente1,2Ana Sofia Delgado,Ana Sofia Delgado1,2Mariana PereiraMariana Pereira7Antnio Condeixa RochaAntónio Condeixa Rocha7Manuel Brs,Manuel Brás1,2Madalena Coutinho Cruz,Madalena Coutinho Cruz1,2Margarida Paulo,Margarida Paulo1,2Ana LousinhaAna Lousinha1Ctia Guerra,Cátia Guerra1,2Rui Cruz Ferreira,Rui Cruz Ferreira1,2Mrio Martins Oliveira,,,,,&#x;,&#x;\r\nMário Martins Oliveira1,2,3,4,5,†,‡
  • 1Arrhythmology, Pacing and Electrophysiology Unit, Cardiology Service, Santa Marta Hospital, Centro Hospitalar Universitário Lisboa Central, Lisbon, Portugal
  • 2Clínica Universitária de Cardiologia, Centro Clínico Académico de Lisboa, Lisboa, Portugal
  • 3Instituto de Fisiologia, Faculdade de Medicina, Universidade de Lisboa, Lisbon, Portugal
  • 4CCUL@RISE, Faculdade de Medicina, Universidade de Lisboa, Lisbon, Portugal
  • 5Comprehensive Health Research Center, NOVA Medical School, Faculdade de Ciências Médicas, NMS, FCM, Universidade NOVA de Lisboa, Lisbon, Portugal
  • 6Departamento de Fisiologia, NOVA Medical School, Faculdade de Ciências Médicas, NMS, FCM, Universidade NOVA de Lisboa, Lisboa, Portugal
  • 7Biosense Webster, Lisbon, Portugal

Background: An ablation catheter and a circular mapping catheter requiring a double transeptal puncture (TSP) for left atrial access have been conventionally used for atrial fibrillation (AF) ablation. Recently, different operators have combined a single transseptal puncture technique with 3D high-density mapping catheters for pulmonary vein isolation (PVI).

Objective: This study aims to compare two strategies, single vs. double TSP, regarding the duration of the procedure, radiation time, complication rates, and outcomes.

Methods: Retrospective analysis of a large cohort of consecutive patients that underwent first PVI with radiofrequency energy (RF), using a point-by-point strategy, with a 3D mapping system, either with single or double TSP, according to the operator's choice.

Results: 285 patients with a mean age of 59.5 ± 11.6 years (36.5% female, 67.7% paroxysmal AF) underwent a point-by-point catheter ablation with RF between July 2015 and March 2020. The mean CHA2DS2-VASc score was 1.7 ± 1.3. Single TSP was performed in 115 (40.3%) patients and double TSP in 170 (59.6%). The operator's experience (≥5 years of AF ablation procedures) was equally distributed among the two groups. The average procedure time (133 ± 31.7 min vs. 123 ± 35.5 min, for single and double TSP, respectively) did reach a statistical difference between both groups (p = 0.008), but there was a substantial advantage regarding fluoroscopy time (13 ± 6.3 min vs. 19 ± 9.1 min, for single and double TSP, respectively; p < 0.001). Acute major complications present similar rates in both groups (2.6% vs. 2.3%, p = 0.799). At the 2-year follow-up, both groups had a similar sinus rhythm maintenance rate (76.5% vs. 78.8%, p = 0.646).

Conclusion: A simplified single-TSP technique using high-density multi-electrode 3D mapping is a safe and highly successful option for AF ablation. This approach yields a substantial reduction in fluoroscopy time, with the potential to avoid acute complications, compared to a conventional double-TSP strategy.

1. Introduction

In the past two decades, significant advancements have been made in managing atrial fibrillation (AF) through catheter ablation. Initially, the procedure focused on isolating pulmonary veins (PV) due to their role in AF initiation (1). So, complete PV isolation (PVI) became the foundation for catheter ablation in AF therapy (2) and circumferential ablation around the PV ostia has become a key element in AF ablation. Catheter ablation is now a routine procedure with a high success rate and a low incidence of complications (35). Randomised trials have shown its superiority over antiarrhythmic drugs when carefully selecting patients (612). As a result, PVI is widely performed as an effective treatment for AF ablation, with current ESC guidelines recommending it as a primary strategy for all AF patients undergoing ablation (13).

Radiofrequency (RF) point-by-point ablation guided by electro-anatomical mapping systems is standard in most electrophysiology laboratories. High-density mapping catheters with more electrodes and smaller distances between them have emerged (14), allowing for more precise and faster mapping and offering detailed insights into arrhythmia mechanisms (15, 16).

Transeptal (TSP) access to the left atrium (LA) remains a challenging step in the ablation procedure (17), with inherent risks and safety concerns, including the major complication of cardiac perforation and cardiac tamponade (18, 19). The original technique for TSP, introduced by Ross (20), is still the standard but demands a high level of operator skill and a steep learning curve.

In many centres, a standard approach for AF ablation involves two sequential TSP punctures (21). Double TSP access allows the insertion of two catheters simultaneously, aiding in real-time visualisation of PV electrograms without needing catheter changes. Another option is a simplified ablation strategy using a single TSP with the multipolar mapping catheter and the ablation catheter through a single sheath (one catheter at a time).

In this study, we assessed the feasibility, safety, and long-term outcomes of a single TSP technique using a high-density mapping catheter. We compared it with the traditional double TSP strategy for AF ablation.

2. Methods

2.1. Study population

We performed a retrospective analysis of a non-randomized cohort of 285 consecutive patients undergoing PVI procedures (without additional left atrial lesions) with point-by-point radiofrequency to treat paroxysmal or persistent AF. The database was registered at the local Institutional Review Board. The hospital ethics committee approved the study protocol (Ethics Committee approval number 974/2020). All participants provided written consent for data collection, and the analysis was conducted according to the Declaration of Helsinki guidelines.

We studied data from all patients over 18 years with AF diagnosis, refractory to at least one anti-arrhythmic drug agent, undergoing catheter ablation as a first procedure from July 2015 to March 2020. Patients with a left atrial flutter, undergoing AF ablation with a single-shot technique or repeated ablation (re-do) were excluded from the current study. AF ablation was performed using a 3-dimensional electroanatomic mapping system (CARTO, Biosense Webster, Inc., Diamond Bar, CA and EnSite NavX/Velocity, Abbott Laboratories, Abbott Park, IL).

Single TSP was performed in 115 patients, and double TSP in 170 cases. Information was collected regarding demographics, anthropometric data, baseline bleeding risk, anti-arrhythmic drugs, LA dimensions, left ventricular ejection fraction (LVEF), and structural heart disease. Regarding the comparison between both techniques, we considered the complication rates as a primary safety endpoint and, as a secondary efficacy endpoint, the freedom from any documented sustained atrial tachyarrhythmia (AF/AT) episode during a 2-year follow-up.

2.2. Ablation procedure

Every patient underwent a routine preprocedural transthoracic echocardiogram to evaluate LVEF and LA dimensions and to screen for structural heart disease. Computed tomography (with LA segmentation) was performed to assess LA anatomy and exclude the presence of intracardiac thrombi. Additionally, if the mentioned imaging study was obtained >48 h before the procedure, transesophageal echocardiography was performed on the day of the ablation to exclude thrombi. All patients underwent ablation with continued oral anticoagulation (at least four weeks before ablation), using warfarin to maintain an international normalised ratio between 2.0 and 3.0. If the patient was under direct oral anticoagulants (DOAC), the last dose was omitted on the day before the ablation.

All the procedures were carried out in conscious sedation and analgesia, using propofol infusion and fentanyl or under general anaesthesia. A deflectable decapolar catheter was positioned through the right femoral vein into the coronary sinus (CS) to guide the TSP, record, and pace the LA. Continuous monitoring of oxygen saturation and ECG were maintained throughout the ablation. Three experienced operators (≥5 years of AF ablation procedures) performed all catheter ablation interventions, and the number of procedures carried out by each of the operators was similarly distributed in both the single and double TSP groups (operator 1 = 102, operator 2 = 87 and operator 3 = 96 total procedures respectively).

Power settings were at the individual operator’s discretion within the 25–40 W range, depending on the LA segment (25–30 W posterior wall; 30–40 W anterior wall). Ablation Index (Biosense Webster, Inc, Diamond Bar, CA) (22) targets guided each lesion: 480 at the roof and anterior walls and 380 at the posterior and inferior walls and LSI (23, 24) (Abbott, Abbott Park, IL) with target LSI values at 4.5 and 4.0 for anterior and posterior walls, respectively.

2.2.1. Double transseptal—double sheath technique

Catheter access was performed using 7, 8 and 8.5 French (F) sheaths inserted in the right femoral vein. During TSP, a decapolar diagnostic catheter was placed in the CS for mapping reference and orientation. TSP was done using a needle system (89 cm, BRK transseptal needle, St. Jude Medical, St. Paul, MN, USA) and a non-deflectable 8 and 8.5 French sheaths SL-1 (Fast-CathTM Transseptal Guiding Introducer SwartzTM SL, Abbott, St. Paul, MN, USA) with fluoroscopic guidance. The 8 F sheath was introduced, and the needle was placed into the superior vena cava and then pulled down. Two movements are detected: the entrance into the right atrium and the fossa oval (FO). After FO identification, the puncture was performed (in the left anterior oblique view). After the first puncture, the same needle system and an 8.5 F introducer (8.5 F, Abbott, St. Paul, MN, USA) were used for the second TSP, performed the same as the described first transseptal puncture. After having both sheaths in the left atrium, a circular mapping catheter and an ablation catheter were inserted through the transseptal sheaths (Figure 1A).

FIGURE 1
www.frontiersin.org

Figure 1. Types of punctures for LA access (double and single puncture). (A) Two punctures in the inter-atrial septum for left atrium access. (B) Single transeptal puncture with the mapping catheter used to create LA geometry and high-density voltage mapping. After completing the geometry and voltage map, the mapping catheter is removed, and the ablation catheter is introduced (C) by the same sheath.

Both sheaths were continuously irrigated with saline during the procedure. Heparin was administered intravenously as a bolus (100 U/kg of standard heparin) immediately after TSP, followed by an additional bolus to maintain an activated clotting time of ≥300 s. Three-dimensional mapping of the LA was performed with either the EnSite NavX/Velocity (Abbott Laboratories, Abbott Park, IL) or CARTO (Biosense Webster, Irvine, California) system. The mapping catheter used was InquiryTM steerable (Abbott) or the Lasso® (Biosense Webster). Radiofrequency applications were performed using an open-irrigated-tip catheter (TactiCath Ablation Catheter®, Sensor Enabled or ThermoCool SmartTouch® _SurroundFlow, Biosense Webster) with point-by-point-lesions. To verify PVI, stimulation with 10 V outputs was delivered through all pairs of electrodes of the circular mapping catheter positioned beyond the ablation line (exit block). Also, pacing from close to the ablation line was performed to confirm electrical isolation (entrance block) (25). Additional applications were delivered if conduction gaps were identified. A successful procedure was defined by the absence of PVI-LA conduction at all pacing sites.

2.2.2. Single transseptal—single sheath technique

Catheter access was performed by 7 and 8.5 French sheaths inserted in the right femoral vein. In addition, a decapolar diagnostic catheter was placed in the CS for mapping reference and orientation during TSP. A single TSP was done by fluoroscopic guidance using a needle system (98 cm, BRK transseptal needle, Abbott, St. Paul, MN, USA) and an Agilis NxT steerable introducer (8.5 F, Abbott, St. Paul, MN, USA), medium (22.4 mm) curl Dual-Reach™ Bi-directional.

Heparin was administered intravenously as described above. The Agilis sheath was continuously irrigated with heparinised saline during the whole procedure. The high-density mapping catheter (CARTO®PENTARAY®, Biosense Webster, Inc., Baldwin Park, CA, USA) was introduced into the LA through the Agilis sheath, and the 3D mapping system (CARTO®, Biosense Webster, USA) and used to create the LA geometry and a high-density voltage mapping. Mapping was done during sinus rhythm or distal CS pacing with the following settings: filtering cycle length: 550–650 ms, LAT stability: 5 ms, position stability: 5 mm, density: 1 mm, voltage scale: <0.2 mV.

After completing the geometry and voltage map, the mapping catheter was removed, and the ablation catheter was introduced by the same sheath (Figures 1B,C). RF ablation was performed using an open-irrigated SmartTouch catheter (Biosense Webster, Inc., Baldwin Park, CA, USA, 3.5 mm open-irrigated tip), by a point-by-point approach, with the catheter in a stable position and a numeric contact force value of ≥10 g. Maximum delivered RF energy did not exceed 40 W, provided by a 500 kHz ablation unit (Stockert EP shuttle, Biosense Webster, Inc., Baldwin Park, CA, USA). Next, remapping was performed to analyse signals, possible gaps and low-voltage areas. If so, the ablation of gaps was followed by remapping to confirm homogeneous low-voltage and PVI (Figure 2). A bi-directional block and low voltage homogeneity of PV and antrum proved PVI.

FIGURE 2
www.frontiersin.org

Figure 2. Electroanatomic mapping using a high-density mapping catheter. Posterior-anterior view of left atrial voltage map with CARTO 3-D mapping system. Panel 1: basal map collected with a high-density catheter (PentArray). Panel 2: second map, after the first pass ablation, with identification of a gap in the ablation line in the posterior aspect of the right superior pulmonary vein. Panel 3: map after the second pass of radiofrequency applications, showing complete isolation of both pairs of veins.

2.3. Post-ablation follow-up

After the ablation procedure, patients were discharged on AAD at the operator’s discretion, together with oral anticoagulation. Patients were observed for routine follow-up in the outpatient clinic 1–3 months after the procedure and every six months (or earlier if symptoms) during the first two years post-ablation. At each visit, a standard 12-lead ECG was obtained. After the blanking period, patients were followed up with a 24 h Holter at each outpatient visit. AAD was continued for six months after CA and was withdrawn—except for beta-blockers—if the patients were free from arrhythmia-related symptoms. Oral anticoagulation was re-evaluated in the third month, and the decision to continue was based on the CHA2DS2-VASc score. In addition, clinical events occurring during the follow-up were evaluated. Atrial arrhythmia recurrence was defined as any documented episode of AF or atrial tachycardia (AF/AT) sustained for >30 s However, symptomatic and clinically typical sustained episodes were considered recurrences even without documentation.

3. Statistical analysis

Descriptive statistics summarised patients’ characteristics, procedural data, safety, and follow-up. Continuous variables were expressed as mean ± SD, and categorical data as frequencies and percentages. Intergroup analysis was made using an unpaired t-test, and intragroup analysis using the Chi-square test. The Chi-square test was used for the comparison of nominal variables. The student t-test and one-way ANOVA were used to compare continuous variables. Comparisons were made using non-missing data only. The Kaplan–Meier model was used to determine cumulative estimates of AF/AT recurrence following the 90-day blanking period through a 2-year follow-up, with between-group comparisons of cumulative event rates calculated using the log-rank test. All tests were two-sided, and a statistical significance was considered when P < 0.05. Analyses were performed using Stata, version 14.1 (StataCorp, College Station, TX).

4. Results

4.1. Baseline characteristics

We enrolled 285 consecutive patients who underwent catheter ablation utilising point-by-point radiofrequency (RF) energy at our institution. In this cohort study, the average age of the patients was 59.5 ± 11.6 years, and 36.5% were female (as indicated in Table 1). Among the patients, 193 (67.7%) had paroxysmal atrial fibrillation (AF); the mean CHA2DS2-VASc score was 1.7 ± 1.3 points. At the time of ablation, all patients were receiving oral anticoagulation therapy. Single transeptal puncture (TSP) was performed in 115 (40.3%) patients, while double TSP was performed in 170 (59.6%) patients. The double TSP group had a higher prevalence of paroxysmal AF. There were no statistically significant differences between the groups regarding age, body mass index, or gender. This procedure represented the initial ablation for all patients.

TABLE 1
www.frontiersin.org

Table 1. Baseline sample characteristics.

Regarding comorbidities (as displayed in Table 2), the groups did not exhibit significant differences concerning conditions such as hypertension, hyperlipidemia, diabetes mellitus, obstructive sleep apnea, chronic obstructive pulmonary disease (COPD), thyroid disease, cancer, heart failure, coronary disease, vascular disease (including stroke, peripheral artery disease, and aortic plaques), and hypertrophic cardiomyopathy. Furthermore, the left ventricular ejection fraction did not display statistically significant differences between the groups. The only variations between the groups were observed in the occurrences of hyperlipidemia and a history of previous stroke or transient ischemic attack, which are not expected to impact the interpretation of the results significantly. On the other hand, the CHADS-VASC score was higher in the single puncture group. As assessed through either echocardiography or CT scan (as shown in Table 3), atrial dimensions exhibited no significant differences between the groups.

TABLE 2
www.frontiersin.org

Table 2. Study sample comorbidities and group comparison.

TABLE 3
www.frontiersin.org

Table 3. Echocardiography and computed tomography characteristics of the left atrium and group comparison.

Regarding the overall procedure duration (as presented in Table 4), the double TSP group had a slightly shorter duration (p = 0.008). However, the single TSP group substantially reduced fluoroscopy time and dwell time (p < 0.001).

TABLE 4
www.frontiersin.org

Table 4. Group comparison of procedure characteristics regarding time and complications.

In the single TSP group, 90% of the cases underwent a second endocardial map after the first pass point-by-point ablation, and 29% received a third map due to gaps. Regarding the number of points collected during mapping with the high-resolution catheter, the average number of points was: 1,020 (388–2,200) for the first map, 1,009 (244–2,617) for the second map and 399 (135–1,019) for the third map (including only PV with gaps).

4.2. Complications occurrence

When we examine the occurrence of complications, major complications show similar rates in both groups (2.6% vs. 2.3%, with a p-value of 0.799). Procedural and periprocedural minor complications were observed in 12 patients (2.6% vs. 5.2%, with a p-value of 0.154). Minor complications included 6 cases (2.1%) of minor hemorrhage at the access site, 2 cases (0.7%) of pseudoaneurysm formation, 1 case (0.3%) of temporary right phrenic palsy, 1 case (0.3%) of air embolism in the coronaries, 1 case (0.3%) of hemoptysis, and 1 case (0.3%) of transient asystole during the procedure (refer to Table 5).

TABLE 5
www.frontiersin.org

Table 5. Complication rates disaggregated by type of transeptal puncture.

4.3. Follow-up

The median follow-up period lasted 24 months, with a range from 12 to 48 months. At the 2-year follow-up mark, both groups displayed a similar rate of maintaining sinus rhythm (76.5% compared to 78.8%, with a p-value of 0.646). The assessments of atrial fibrillation recurrence over a 24-month follow-up in AF patients who underwent catheter ablation, stratified by transeptal puncture (single vs. double), revealed no distinction between the two approaches (p = 0.704) (Figure 3). Also, when examining the recurrence rates stratified by transeptal puncture (single vs. double) and the type of AF (paroxysmal vs. persistent), we observed no noteworthy differences between the groups (log-rank test, p = 0.113).

FIGURE 3
www.frontiersin.org

Figure 3. Kaplan meier survival curves estimates of AF recurrence during a mean follow-up of 24 months stratified by transeptal puncture: single vs. double (log-rank, p = 0.704).

5. Discussion

5.1. Safety and feasibility of the single transeptal puncture approach in AF ablation

The present study demonstrated the feasibility and safety of a simplified single TSP puncture using 3D high-density PVI mapping using a point-by-point RF approach in a large cohort of AF patients. In addition, we compared double-TSP catheterisation, used in many centres as a standard technique, with a single TSP technique, using a 3D high-density mapping catheter and the ablation catheter through a single sheath (each catheter at a time).

There was not a substantial distinction between the two approaches in terms of the overall procedure duration, although the single puncture strategy did result in a slightly lengthier procedure time (133 ± 31.7 compared to 123 ± 35.5, with a p-value of 0.008). However, the extent of this difference (10 min) may not hold clinical significance. We attribute this variance to the operators’ initial learning curve, as it might be necessary to change catheters multiple times in the single puncture strategy, leading to a marginal increase in the total procedure time. Nevertheless, there was a notable reduction in dwell time in the single puncture group (p < 0.001).

It is crucial to emphasize that fluoroscopy times were significantly lower in the single transeptal puncture strategy. This substantial reduction in fluoroscopy time is important for patients and medical operators, as this decreased radiation exposure is linked to reduced risks (26).

The transeptal puncture (TSP) is a pivotal step in the atrial fibrillation (AF) ablation procedure. In theory, the double catheterization technique could introduce additional risks. The documented occurrence of pericardial effusion during catheter-based AF ablation varies between 0.5% and 4%, with cardiac tamponade observed in approximately 1% of cases (27, 28). A recently published meta-analysis of randomized clinical trials (29), which included patients undergoing their initial atrial fibrillation ablation procedure, revealed an overall complication rate of 4.5%. In this analysis, the incidence of severe procedure-related complications was 2.4%, which aligns with our findings.

Despite the need to exchange catheters a few times during the procedure, no stroke cases occurred in any group. Ischemic stroke complications can have dramatic consequences in AF ablation, with an incidence reported to be between 1% and 2% (30).

It’s important to emphasize that the authors did not employ adjunctive tools for transeptal puncture (TSP). The use of intracardiac echocardiography and transesophageal echocardiography guidance could play a crucial role in reducing adverse events associated with TSP and facilitating challenging transseptal catheterization (31). These imaging tools theoretically could have prevented some of the adverse events observed in our study. Further investigations with larger sample sizes may provide more clarity on this matter.

The single TSP approach resulted in fewer minor complications than the double-TSP catheterisation patients (2.6% vs. 5.2%), although this difference did not reach statistical significance. However, apart from air embolisation, it’s challenging to establish a clear correlation between the technique used to access the atrium and the occurrence of other complications. The absence of air embolisation complications in the single puncture group is noteworthy. It can be attributed to meticulous sheath irrigation throughout the procedure and careful aspiration during catheter changes.

Another aspect worth highlighting is that our centre did not have access to steerable sheaths that could be visualised using an electroanatomical mapping system when these procedures were conducted. Evidence indicates that this sheath type can substantially reduce fluoroscopy time (32).

5.2. Long-term outcome after AF catheter ablation

PVI, the cornerstone of any AF ablation procedure for paroxysmal and persistent AF, was the strategy therapy followed in this cohort. The AF/AT recurrence rate 24 months after the ablation was less than 30% for the entire cohort. In the current study, the AF/AT-free survival rate was slightly improved compared to other studies with long-term follow-up available in the literature. Kardos et al., in a study (33) comparing RF energy using contact force sensing and cryoballoon ablation for PVI in paroxysmal AF patients, showed freedom from AF/AT after a 24-month follow-up of around 66%. Ganesan et al.’s systematic review and meta-analysis included 6,167 patients with paroxysmal and non-paroxysmal AF from 19 studies undergoing AF ablation, with a mean follow-up of ≥24 months. They found freedom from AF/AT of 53% after one CA, with lower success rates for non-paroxysmal AF (3).

It should also be noted that both techniques have similar recurrence rates at 24 months follow-up. This comparable long-term outcome suggests that the single TSP technique is not sacrificing effectiveness for the sake of its other advantages. This is crucial for the overall success and sustainability of the ablation procedure.

Both groups equally distributed the operator’s experience, with ≥5 years of AF ablation procedures. This equal distribution minimises the potential bias related to operator experience, making the comparison more reliable.

We would also like to point out that a steerable sheath was used in the single TSP group. In contrast to a non-steerable sheath, the use of steerable sheath technology enhances control over catheter manipulation. This advancement theoretically enables a broader spectrum of catheter orientations and improved stability, potentially leading to enhanced tissue contact and, consequently, more effective ablation lesions. One systematic review and meta-analysis that analysed the results of using both strategies found that the fluoroscopic and RF application times were comparable (34). Another recent meta-analysis (35) also considered comparing these two technologies for RF ablation of AF. It concluded that steerable sheaths can effectively reduce the recurrence rate of AF and the occurrence of acute PVs reconnection events. However, there is no advantage in shortening the total RF time, fluoroscopy time, total surgical time and reducing complications (35). Considering that our study aimed to evaluate the complications and long-term results, using the steerable sheath might influence the recurrence rate but not the other parameters reported in our results.

5.3. Study limitations

We wish to emphasise several limitations in our research. Firstly, this study was conducted as a non-randomized single-centre investigation. However, it's worth noting that both groups consisted of atrial fibrillation patients who were consecutively enrolled for point-by-point pulmonary vein isolation, which somewhat mitigates the absence of randomisation. Secondly, the significant advancements in 3D mapping systems and the increasing experience of the operators over the course of the study, which spanned five years, may have influenced the observed reduction in radiation exposure times. It's important to highlight that our primary objective was to assess the safety of catheter ablation, specifically focusing on single-transseptal puncture (TSP) and double-TSP approaches. Thirdly, the utilisation of 24 h Holter recordings, as opposed to 7-day recordings, could potentially lead to an underestimation of AF recurrence rates. Nevertheless, it is noteworthy that this assessment method has been employed by multiple researchers, and in our study, it was consistently applied to both groups, minimising the likelihood of introducing substantial bias. Fourthly, it is important to point out that a steerable sheath was used in the single TSP group, which may introduce some variance in the comparison between the groups.

Fifthly we did not perform pre- and post-catheter ablation cerebral magnetic resonance imaging in this study. Consequently, we could not evaluate the incidence of silent cerebral lesions (36), which could be significant, especially in catheter exchange within the single transeptal puncture group. Lastly, while our approach theoretically simplifies the catheter manipulation process, it is important to acknowledge that it may demand a longer learning curve than conventional techniques, which should be considered when implementing this method.

6. Conclusion

This retrospective analysis of a large cohort of consecutive patients highlights the viability, safety, and high success rate of employing a single transeptal puncture and a single sheath for catheter placement in the left atrium during atrial fibrillation ablation. This approach represents a valuable alternative to the conventional practice of using double transseptal catheterisation and double sheaths simultaneously. Moreover, it offers an option for operators seeking to reduce x-ray exposure and minimise potential complications associated with a second TSP procedure while delivering promising long-term results for paroxysmal and persistent AF.

In summary, the single TSP technique presents advantages such as reduced fluoroscopy time, the potential avoidance of acute complications, and comparable long-term outcomes. These findings indicate that the single TSP approach is feasible and preferable in certain aspects, contributing to the enhancement and optimisation of AF ablation procedures.

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics statement

The studies involving humans were approved by Comissão de Ética do Centro Hospitalar Universitário de Lisboa Central. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.

Author contributions

PS: Conceptualization, Investigation, Writing – original draft, Writing – review & editing. BT: Formal Analysis, Investigation, Writing – review & editing. SL: Formal Analysis, Writing – review & editing. GP: Resources, Writing – review & editing. BV: Resources, Writing – review & editing. AD: Resources, Writing – review & editing. MP: Resources, Writing – review & editing. AR: Data curation, Resources, Writing – review & editing. MB: Resources, Writing – review & editing. MC: Data curation, Resources, Writing – review & editing. MP: Methodology, Resources, Writing – review & editing. AL: Resources, Writing – review & editing. CG: Formal Analysis, Resources, Writing – review & editing. RF: Supervision, Writing – review & editing. MO: Data curation, Writing – original draft, Writing – review & editing.

Funding

The author(s) declare that no financial support was received for the research, authorship, and/or publication of this article.

Conflict of interest

MO has served as a speaker for Medtronic and is a member of the European Advisory Board of Medtronic. MP and AR are employees of Biosense Webster, Portugal.

The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Haïssaguerre M, Jaïs P, Shah DC, Takahashi A, Hocini M, Quiniou G, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. (1998) 339(10):659–66. doi: 10.1056/NEJM199809033391003

CrossRef Full Text | Google Scholar

2. Oral H, Pappone C, Chugh A, Good E, Bogun F, Pelosi F Jr, et al. Circumferential pulmonary-vein ablation for chronic atrial fibrillation. N Engl J Med. (2006) 354(9):934–41. doi: 10.1056/NEJMoa050955

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Ganesan AN, Shipp NJ, Brooks AG, Kuklik P, Lau DH, Lim HS, et al. Long-term outcomes of catheter ablation of atrial fibrillation: a systematic review and meta-analysis. J Am Heart Assoc. (2013) 2(2):e004549. doi: 10.1161/JAHA.112.004549

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Jaïs P, Cauchemez B, Macle L, Daoud E, Khairy P, Subbiah R, et al. Catheter ablation versus antiarrhythmic drugs for atrial fibrillation: the A4 study. Circulation. (2008) 118(24):2498–505. doi: 10.1161/CIRCULATIONAHA.108.772582

CrossRef Full Text | Google Scholar

5. Yang PS, Sung JH, Jang E, Yu HT, Kim TH, Uhm JS, et al. Catheter ablation improves mortality and other outcomes in real-world patients with atrial fibrillation. J Am Heart Assoc. (2020) 9(11):e015740. doi: 10.1161/JAHA.119.015740

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Calkins H, Reynolds MR, Spector P, Sondhi M, Xu Y, Martin A, et al. Treatment of atrial fibrillation with antiarrhythmic drugs or radiofrequency ablation: two systematic literature reviews and meta-analyses. Circ Arrhythm Electrophysiol. (2009) 2(4):349–61. doi: 10.1161/CIRCEP.108.824789

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Kawaji T, Shizuta S, Morimoto T, Aizawa T, Yamagami S, Yoshizawa T, et al. Very long-term clinical outcomes after radiofrequency catheter ablation for atrial fibrillation: a large single-centre experience. Int J Cardiol. (2017) 249:204–13. doi: 10.1016/j.ijcard.2017.09.023

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Wazni OM, Marrouche NF, Martin DO, Verma A, Bhargava M, Saliba W, et al. Radiofrequency ablation vs antiarrhythmic drugs as first-line treatment of symptomatic atrial fibrillation: a randomised trial. JAMA. (2005) 293(21):2634–40. doi: 10.1001/jama.293.21.2634

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Pappone C, Augello G, Sala S, Gugliotta F, Vicedomini G, Gulletta S, et al. A randomized trial of circumferential pulmonary vein ablation versus antiarrhythmic drug therapy in paroxysmal atrial fibrillation: the APAF study. J Am Coll Cardiol. (2006) 48(11):2340–7. doi: 10.1016/j.jacc.2006.08.037

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Piccini JP, Lopes RD, Kong MH, Hasselblad V, Jackson K, Al-Khatib SM. Pulmonary vein isolation for the maintenance of sinus rhythm in patients with atrial fibrillation: a meta-analysis of randomized, controlled trials. Circ Arrhythm Electrophysiol. (2009) 2(6):626–33. doi: 10.1161/CIRCEP.109.856633

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Cosedis Nielsen J, Johannessen A, Raatikainen P, Hindricks G, Walfridsson H, Kongstad O, et al. Radiofrequency ablation as initial therapy in paroxysmal atrial fibrillation. N Engl J Med. (2012) 367(17):1587–95. doi: 10.1056/NEJMoa1113566

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Wilber DJ, Pappone C, Neuzil P, De Paola A, Marchlinski F, Natale A, et al. Comparison of antiarrhythmic drug therapy and radiofrequency catheter ablation in patients with paroxysmal atrial fibrillation: a randomized controlled trial. JAMA. (2010) 303(4):333–40. doi: 10.1001/jama.2009.2029

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Hindricks G, Potpara T, Dagres N, Bax JJ, Boriani G, Dan GA, et al. 2020 ESC guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European association for cardio-thoracic surgery (EACTS). Eur. Heart J. (2021) 42:373–498. doi: 10.1093/eurheartj/ehaa612

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Augello G, Vicedomini G, Saviano M, Crisa S, Mazzone P, Ornago O, et al. Pulmonary vein isolation after circumferential pulmonary vein ablation: comparison between Lasso and three-dimensional electroanatomical assessment of complete electrical disconnection. Heart Rhythm. (2009) 6(12):1706–13. PMID: 19959116. doi: 10.1016/j.hrthm.2009.09.008

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Tung R, Ellenbogen KA. Emergence of multielectrode mapping: on the road to higher resolution. Circ Arrhythm Electrophysiol. (2016) 9(6):e004281. PMID: 27307521. doi: 10.1161/CIRCEP.116.004281

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Siebermair J, Neumann B, Risch F, Riesinger L, Vonderlin N, Koehler M, et al. High-density mapping guided pulmonary vein isolation for treatment of atrial fibrillation—two-year clinical outcome of a single centre experience. Sci Rep. (2019) 9(1):8830. doi: 10.1038/s41598-019-45115-0

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Manolis AS. Transseptal access to the left atrium: tips and tricks to keep it safe derived from single operator experience and review of the literature. Curr Cardiol Rev. (2017) 13(4):305–18. doi: 10.2174/1573403X13666170927122036

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Roelke M, Smith AJ, Palacios IF. The technique and safety of transseptal left heart catheterization: the Massachusetts general hospital experience with 1,279 procedures. Cathet Cardiovasc Diagn. (1994) 32(4):332–9. doi: 10.1002/ccd.1810320409

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Holmes DR Jr, Nishimura R, Fountain R, Turi ZG. Iatrogenic pericardial effusion and tamponade in the percutaneous intracardiac intervention era. JACC Cardiovasc Interv. (2009) 2(8):705–17. doi: 10.1016/j.jcin.2009.04.019

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Ross J Jr. Transeptal left heart catheterisation: a new method of left atrial puncture. Ann Surg. (1959) 149(3):395–401. doi: 10.1097/00000658-195903000-00009

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Yamada A, McElderry HT, Epstein AE, Plumb VJ, Kay GN. One-puncture, double-transseptal catheterisation manoeuvre in the catheter ablation of atrial fibrillation. Europace. (2007) 9(7):487–9. doi: 10.1093/europace/eum070

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Nakagawa H, Ikeda A, Govari A, Papaioannou T, Constantine G, Bar-Tal M. Prospective study using a new formula incorporating contact force, radiofrequency power and application time (force-power-time index) for quantifying lesion formation to guide long continuous atrial lesions in the beating canine heart. Circulation. (2013) 128:A12104. Available at: https://www.ahajournals.org/doi/10.1161/circ.128.suppl_22.A12104

Google Scholar

23. Whitaker J, Fish J, Harrison J, Chubb H, Williams SE, Fastl T, et al. Lesion index-guided ablation facilitates continuous, transmural, and durable lesions in a porcine recovery model. Circ Arrhythm Electrophysiol. (2018) 11(4):e005892. doi: 10.1161/CIRCEP.117.005892

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Venkatesh Prasad K, Bonso A, Woods CE, Goya M, Matsuo S, Padanilam BJ, et al. Lesion index-guided workflow for the treatment of paroxysmal atrial fibrillation is safe and effective—final results from the LSI workflow study. Heart Rhythm O2. (2022) 3(5):526–35. doi: 10.1016/j.hroo.2022.06.004

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Kircher S, Sommer P. Electrophysiological evaluation of pulmonary vein isolation. J Atr Fibrillation. (2013) 6(3):934. doi: 10.4022/jafib.934

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Sommer P, Sciacca V, Anselmino M, Tilz R, Bourier F, Lehrmann H, et al. Practical guidance to reduce radiation exposure in electrophysiology applying ultra low-dose protocols: a European heart rhythm association review. Europace. (2023) 25(7):euad191. doi: 10.1093/europace/euad191

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Murakawa Y, Yamane T, Goya M, Inoue K, Naito S, Kumagai K, et al. Japanese heart rhythm society members. Incidence and predictors of pericardial effusion as an early complication of catheter ablation for atrial fibrillation: the Japanese Catheter Ablation Registry of Atrial Fibrillation (J-CARAF). J Arrhythm. (2017) 33(5):430–3. doi: 10.1016/j.joa.2017.04.009

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Scanavacca MI. How to prevent, recognise and manage complications of AF ablation? Rev Port Cardiol. (2017) 36(Suppl 1):43–9 English, Portuguese. doi: 10.1016/j.repc.2017.09.005

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Benali K, Khairy P, Hammache N, Petzl A, Da Costa A, Verma A, et al. Procedure-related complications of catheter ablation for atrial fibrillation. J Am Coll Cardiol. (2023) 81(21):2089–99. doi: 10.1016/j.jacc.2023.03.418

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Haeusler KG, Kirchhof P, Endres M. Left atrial catheter ablation and ischemic stroke. Stroke. (2012) 43(1):265–70. doi: 10.1161/STROKEAHA.111.627067

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Mitacchione G, Curnis A, Forleo GB. Transseptal catheterization of the native septum for atrial fibrillation ablation in presence of septal occluder device: a novel approach with real-time 3D transesophageal echocardiographic guidance. J Interv Card Electrophysiol. (2020) 59(1):79–80. doi: 10.1007/s10840-020-00703-3

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Fitzpatrick N, Mittal A, Galvin J, Jauvert G, Keaney J, Keelan E, et al. The impact of steerable sheath visualization during catheter ablation for atrial fibrillation. Europace. (2023) 25(4):1345–51. doi: 10.1093/europace/euad029

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Kardos A, Kis Z, Som Z, Nagy Z, Foldesi C. Two-year follow-up after contact force sensing radiofrequency catheter and second-generation cryoballoon ablation for paroxysmal atrial fibrillation: a comparative single centre study. Biomed Res Int. (2016) 2016:6495753. doi: 10.1155/2016/6495753

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Mhanna M, Beran A, Al-Abdouh A, Sajdeya O, Barbarawi M, Alsaiqali M, et al. Steerable versus nonsteerable sheath technology in atrial fibrillation ablation: a systematic review and meta-analysis. J Arrhythm. (2022) 38(4):570–9. doi: 10.1002/joa3.12742

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Jin X, Zhou Y, Wu Y, Xie M. Safety and efficacy of steerable versus non-steerable sheaths for catheter ablation of atrial fibrillation systematic review and meta-analysis. BMJ Open. (2023) 13(9):e068350. doi: 10.1136/bmjopen-2022-068350

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Anselmino M, Matta M, Toso E, Ferraris F, Castagno D, Scaglione M, et al. Silent cerebral embolism during atrial fibrillation ablation: pathophysiology, prevention and management. J Atr Fibrillation. (2013) 6(2):796. doi: 10.4022/jafib.796

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: atrial fibrillation, catheter ablation, transseptal puncture, complications, safety

Citation: Silva Cunha P, Teixeira BL, Laranjo S, Portugal G, Valente B, Delgado AS, Pereira M, Rocha AC, Brás M, Cruz MC, Paulo M, Lousinha A, Guerra C, Ferreira RC and Oliveira MM (2023) A simplified single transseptal puncture approach using high-density 3D voltage mapping for atrial fibrillation ablation: acute complications and long-term results. Front. Cardiovasc. Med. 10:1309900. doi: 10.3389/fcvm.2023.1309900

Received: 8 October 2023; Accepted: 10 November 2023;
Published: 23 November 2023.

Edited by:

Matteo Anselmino, University of Turin, Italy

Reviewed by:

Peter Kupo, University of Pécs, Hungary
Vassil B. Traykov, Acibadem City Clinic Tokuda Hospital, Bulgaria

© 2023 Silva Cunha, Teixeira, Laranjo, Portugal, Valente, Delgado, Pereira, Rocha, Brás, Cruz, Paulo, Lousinha, Guerra, Ferreira and Oliveira. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Pedro Silva Cunha cGVkcm8uY3VuaGFAY2hsYy5taW4tc2F1ZGUucHQ=

These authors have contributed equally to this work

This author takes responsibility for all aspects of the reliability and freedom from bias of the data presented and their discussed interpretation

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.