AUTHOR=Hertel Julie Norup , Jerltorp Kezia , Hansen Malthe Emil Høtbjerg , Isaksen Jonas L. , Sattler Stefan Michael , Linz Benedikt , Chaldoupi Sevasti-Maria , Jespersen Thomas , Saljic Arnela , Gang Uffe , Manninger Martin , Linz Dominik TITLE=3D-electroanatomical mapping of the left atrium and catheter-based pulmonary vein isolation in pigs: A practical guide JOURNAL=Frontiers in Cardiovascular Medicine VOLUME=10 YEAR=2023 URL=https://www.frontiersin.org/journals/cardiovascular-medicine/articles/10.3389/fcvm.2023.1139364 DOI=10.3389/fcvm.2023.1139364 ISSN=2297-055X ABSTRACT=Aim

To propose a standardized workflow for 3D-electroanatomical mapping guided pulmonary vein isolation in pigs.

Materials and methods

Danish female landrace pigs were anaesthetized. Ultrasound-guided puncture of both femoral veins was performed and arterial access for blood pressure measurement established. Fluoroscopy- and intracardiac ultrasound-guided passage of the patent foramen ovale or transseptal puncture was performed. Then, 3D-electroanatomical mapping of the left atrium was conducted using a high-density mapping catheter. After mapping all pulmonary veins, an irrigated radiofrequency ablation catheter was used to perform ostial ablation to achieve electrical pulmonary vein isolation. Entrance- and exit-block were confirmed and re-assessed after a 20-min waiting period. Lastly, animals were sacrificed to perform left atrial anatomical gross examination.

Results

We present data from 11 consecutive pigs undergoing pulmonary vein isolation. Passage of the fossa ovalis or transseptal puncture was uneventful and successful in all animals. Within the inferior pulmonary trunk 2–4 individual veins as well as 1–2 additional left and right pulmonary veins could be cannulated. Electrical isolation by point-by-point ablation of all targeted veins was successful. However, pitfalls including phrenic nerve capture during ablation, ventricular arrhythmias during antral isolation close to the mitral valve annulus and difficulties in accessing right pulmonary veins were encountered.

Conclusion

Fluoroscopy- and intracardiac ultrasound-guided transseptal puncture, high-density electroanatomical mapping of all pulmonary veins and complete electrical pulmonary vein isolation can be achieved reproducibly and safely in pigs when using current technologies and a step-by-step approach.