AUTHOR=Ma Likang , Chai Tianci , Yang Xiaojie , Zhuang Xinghui , Wu Qingsong , Chen Liangwan , Qiu Zhihuang TITLE=Outcomes of hemi- vs. total arch replacement in acute type A aortic dissection: A systematic review and meta-analysis JOURNAL=Frontiers in Cardiovascular Medicine VOLUME=9 YEAR=2022 URL=https://www.frontiersin.org/journals/cardiovascular-medicine/articles/10.3389/fcvm.2022.988619 DOI=10.3389/fcvm.2022.988619 ISSN=2297-055X ABSTRACT=Background

Acute type A aortic dissections (ATAAD) pose a challenge to surgeons due to high mortality, and decision making regarding the appropriate procedure is controversial. This study compared the outcomes of hemiarch and total arch replacement for ATAAD.

Methods

The PubMed, Web of Science, Embase and Cochrane databases were searched for comparative studies on hemiarch versus total arch replacement that were published before May 1, 2022.

Results

We included 23 observational studies with a total of 4,576 patients. Combined data analysis showed that early mortality (RR = 0.82; 95% CI: 0.70–0.97; P = 0.02), incidence of postoperative permanent neurological dysfunction (RR = 0.72; 95%CI:0.54∼0.94; P = 0.02), and incidence of renal failure and dialysis (RR = 0.82; 95%CI:0.71∼0.96; P = 0.01) were all lower for hemiarch than for total arch replacement. However, hemiarch replacement had a higher rate of late mortality (RR = 1.37; 95%CI:1.10∼1.71; P = 0.005). There were no statistically significant differences between the two groups in terms of re-operation for bleeding, aortic re-operation, or postoperative pneumonia.

Conclusion

In this study, hemiarch replacement had better early outcomes but a higher late mortality rate than total arch replacement. Decisions regarding the extent of arch repair should be made according to location and extent of ATAAD and the experience of surgeons to ensure the most favorable prognosis.

Systematic review registration:

[INPLASY.COM], identifier [INPLASY202250088].