Skip to main content

ORIGINAL RESEARCH article

Front. Cardiovasc. Med., 06 September 2022
Sec. Cardiovascular Imaging

Relation of quantitative flow ratio with transit time coronary artery bypass graft flow measurement

\r\nCong Chen&#x;Cong ChenYang Zhao&#x;Yang ZhaoWei LiWei LiKui ZhangKui ZhangHaiming DangHaiming DangTaoshuai LiuTaoshuai LiuYue SongYue SongJubing ZhengJubing ZhengRan Dong
Ran Dong*
  • Center of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing, China

Background: Quantitative flow ratio (QFR) is a new functional index to assess the functional significance of coronary stenosis. While whether there is an association between QFR and transit-time flow measurement (TTFM) parameters of the target coronary artery has not been well addressed.

Methods: A total of 89 patients receiving the in situ left internal thoracic artery (LITA) grafts to the left anterior descending artery (LAD), and 19 patients undergoing the saphenous vein grafts (SVG) were enrolled in this retrospective study. The QFR value of the LAD was evaluated preoperatively. According to the QFR values, patients with the LITA to the LAD bypass grafts were divided into two groups (group A1: QFR < 0.75, group A2: QFR ≥ 0.75), and SVG patients were divided into two groups (V1 group: QFR < 0.75, V2 group: QFR ≥ 0.75).

Results: In groups A1 and A2, respectively, median graft flow (Qm) was 44 (34) mL/minute and 26.5 (30.0) ml/minute; median pulsatility index (PI) was 2.00 (1.00) and 2.65 (0.90). Significant differences were observed in Qm (P = 0.034) and PI (P = 0.030). And the correlation coefficients of the TTFM variables with QFR were Qm: r = r = −0.226, (P = 0.036), PI: r = 0.265 (P = 0.012) among the LITA to LAD population.

Conclusion: TTFM variables, especially the PI, of the LITA in situ graft to the LAD during Coronary artery bypass grafting (CABG) are strongly affected by preoperative QFR values. Moreover, in functionally mild coronary stenosis, the chance of competitive flow increases.

Introduction

Coronary artery bypass grafting (CABG) is one of the main therapeutic strategies for coronary artery stenosis and improving the prognosis of patients with coronary heart disease. However, these grafts may become occluded or narrowed over time, especially with grafting less critical stenosis. In coronary surgery, the choice of the target vessel is particularly important. Traditional coronary surgery is performed only based on anatomical methods such as preoperative coronary angiography (CAG), rather than physiological function assessment. However, researchers have found that CAG, as a way to assess coronary stenosis, only based on the anatomical points of view, can easily overestimate or underestimate coronary artery stenosis (1). Assessment of the functional severity of stenosis in a coronary artery is urgently needed.

Several international studies such as the FFR Versus Angiography for Multivessel Evaluation (FAME) study and deferral of percutaneous coronary intervention (DEFER) study have all verified that utilizing functional assessment of coronary artery through the fractional flow reserve (FFR) to guide percutaneous coronary intervention (PCI) has excellent results (2, 3). European Society of Cardiology (ESC) revascularization guidelines have adopted FFR as the gold standard for assessing the severity of coronary artery stenosis (40–90%) (4). Studies have shown that FFR may simplify CABG procedures and optimize arterial graft patency without any significant impact on venous grafts (510). FFR-guided CABG was associated with lower overall death, angina, and myocardial infarction rates compared with angiography-guided CABG (6, 8). A prospective study conducted by Botman’s team showed that in patients with FFR ≥ 0.7, the proportion of graft restenosis within 1 year exceeded 10% (11). Honda and his colleagues reported significant differences in graft flow and pulsatility index among the groups (divided by the cutoff value of 0.75 in FFR) (12). These studies provide a clinical basis for us to carry out FFR-guided CABG studies.

Quantitative flow ratio (QFR) is a novel method for evaluating the functional significance of coronary stenosis by computation of FFR in the vessel based on 3-dimensional angiographic reconstruction and fluid dynamics algorithms (13, 14). The Functional Assessment by Various Flow Reconstructions (FAVOR) pilot study showed promising results for core laboratory-based QFR computation in identifying the presence of functionally significant stenosis in selected patients (13). Its accuracy and consistency based on FFR have been widely verified (15, 16). FAVOR III China indicates fewer myocardial infarctions and ischemia-driven revascularisations in the QFR-guided group than in the angiography-guided group (17). The QFR technique only takes 3.6 min to measure FFR and is suitable for more than 97% of coronary angiography images. Overall, QFR technology has high clinical application prospects. However, only limited evidence exists on the role of preoperative QFR in patients undergoing CABG currently, finding that the QFR-guided surgical coronary revascularization is safe and reduces unnecessary bypass grafting (18).

Therefore, our study aimed to analyze the efficiency of QFR in coronary artery functional stenosis assessment and evaluate the feasibility of performing QFR analysis in guiding CABG by exploring the correlation between QFR and the transit-time flow measurement (TTFM) measurement as well as the graft blood flow pattern.

Patients and methods

Study patients

This study retrospectively included 108 patients with coronary heart disease undergoing CABG in the sixth Department of Cardiac Surgery of Beijing Anzhen Hospital from January 2019 to June 2020. It has been approved by the hospital ethics committee.

All patients underwent coronary angiography before surgery, and the QFR value of the anterior descending coronary artery was calculated. According to the preoperative QFR value of the descending artery, the patients who undertook the left internal thoracic artery to the anterior descending artery bypass graft were divided into two groups (group A1: QFR < 0.75, group A2: QFR ≥ 0.75), and patients with saphenous vein to the descending branch bypass were divided into V1 group: QFR < 0.75 and V2 group: QFR ≥ 0.75. In situ LITA to LAD and SVG to LAD were used. TTFM was used to evaluate the Qm, PI, and systolic reverse blood flow of each group. In addition, the short-term patency of the graft vessel after bypass graft was followed up. Baseline patient characteristics as well as operative procedure data are shown in Table 1.

TABLE 1
www.frontiersin.org

Table 1. Patient characteristics.

Preoperative quantitative flow ratio measurement and surgical strategy

All patients underwent coronary angiography before surgery, and the results of the angiography were sent to the core laboratory of Shanghai Pulse Medical Technology, Inc., for QFR value calculation and analysis. The results were sent back in reports like that shown in Figure 1. And The relation between QFR and the degree of coronary angiographic stenosis is shown in Figure 2. Cardiac surgeons defined the surgical revascularization strategy based on coronary angiography alone, blinded to the QFR values. Surgery was performed with off-pump CABG (106 cases), on-pump bypass assisted non-stop (1 case), and on-pump CABG (1 case).

FIGURE 1
www.frontiersin.org

Figure 1. Case example of QFR report. There is a moderate stenosis (diameter stenosis = 46.4%) with QFR value = 0.69 in a 58-year old male patient. Qm (33 ml/min) and PI (3), the backflow component of TTFM is not evident. Postoperative multislice computed tomography angiography shows patency of the LITA graft.

FIGURE 2
www.frontiersin.org

Figure 2. The relation between QFR and the degree of coronary angiographic stenosis.

Intraoperative flow measurement

The TTFM was used to measure the graft flow during the operation. The validity of bridge flow measurement is mentioned in the European Society of Cardiology and the European Association of Cardio-thoracic Surgery (ESC-EACTS) guidelines (19). TTFM was measured intraoperatively using a 3 mm or 4 mm flow probe. We routinely obtained TTFM-related parameters twice: (1) just after graft anastomosis during off-pump CABG and on-pump CABG to determine the need for graft modification. (2) In both on-pump and off-pump CABG, when the hemodynamic status becomes stable before chest closure, the mean blood pressure is between 80 and 100 mmHg, the heart rate is between 70 and 100 beats per minute, and a small amount of inotropy and vasopressors used to maintain hemodynamic stability. The parameters measured by the transient-time flow meter include Qm, PI, and systolic reverse flow from the latter flow profiles. Reverse blood flow is measured as the percentage of the area below the basic line, compared with the total flow area. Three months after the operation, patients were evaluated for the patency of the grafts. Multislice computed tomography angiography (MSCTA) was preferred, and individual patients were evaluated by coronary angiography.

Statistical analysis

STATA 14.0 statistical software was used for data collation and analysis. Categorical variables are expressed as the number of cases (percentage), the chi-square test or Fisher’s exact probability method is used for comparison between groups, and the rank sum test is used for rank variables. Non-normally distributed measurement variables are represented by M (IQR), and the U test was used for comparison between groups. Continuous data are presented as mean ± SD. Spearman correlation coefficient was used to evaluate the correlation between preoperative QFR and Qm as well as PI. Two-tailed test, a P value less than 0.05 is considered statistically significant.

Results

A total of 108 patients were divided into 4 groups according to their preoperative QFR value of descending branch. The patients (89 cases) who used LITA-LAD bypass were divided into the A1 group (79 cases): QFR < 0.75, A2 group (10 cases): QFR ≥ 0.75, the patients who used SVG-LAD bypass (19 cases) were divided into V1 group (15 cases): QFR<0.75 andV2 group (4 cases): QFR ≥ 0.75.

Surgery was performed with off-pump CABG (106 cases), on-pump beating-heart (1 case), and on-pump CABG (1 case). All patients underwent coronary artery bypass grafting alone without other cardiac surgery at the same time. There were no deaths or major adverse cardiovascular events during hospitalization.

Quantitative flow ratio and transit-time flow measurement

The median of Qm in each group is group A1: 44.0 (34.0)ml/min, group A2: 26.5 (30.0) ml/min, group V1: 67.0 (45.0) ml/min, V2 group: 60.5 (27.3) ml/min; the median of PI in each group were A1 group: 2.0 (1.0), A2 group: 2.7 (0.9), V1 group: 1.4 (0.5), V2 group: 1.8 (0.8); the number of patients with systolic reverse blood flow are 25 (31.65%), 7 (70.00%), 1 (6.25%), and 1 (25.00%) in respective groups. Among patients who used LITA in situ graft to LAD, there were significant differences in Qm (P = 0.034) and PI (P = 0.030) between the A1 group and the A2 group, that is patients with higher QFR have lower Qm and higher PI values (Figure 3). Nevertheless, we did not find a significant difference between the V1 and V2 groups either in PI (P = 0.469) or Qm (P = 0.596). A negative correlation was observed between QFR and Qm (r = −0.150, P = 0.162), in contrast, QFR and PI showed positive correlation (r = 0.265, P = 0.012) (Figure 4). Since the non-significant correlation between QFR and Qm, we carefully analyzed the relevant data and found that EF values were closely correlated with Qm, so we controlled EF values for variables and also dealt with outliers, and the results were satisfactory (r = −0.226, P = 0.036). And in the young and middle-aged groups (age < 65 years), a more significant correlation (r = −0.348, P = 0.008) was found. We believe that the insufficient sample size in this study led to such results, and since this is a retrospective trial, its findings are susceptible to bias due to other confounding factors. Therefore, prospective studies with larger sample sizes are needed to investigate the effect of QFR on parameters related to intraoperative grafts.

FIGURE 3
www.frontiersin.org

Figure 3. Among patients who used LITA in situ graft to LAD, there were significant differences in Qm (P = 0.034) and PI (0.030) between the A1 group and the A2 group. In situ LITA-LAD graft flow increased with the increase of coronary stenosis severity while the PI decreased.

FIGURE 4
www.frontiersin.org

Figure 4. Correlations of the preoperative QFR of the LAD and the parameters of intraoperative TTFM of the in situ LITA graft to the LAD, including Qm and PI.

As shown in Figure 5, the correlation coefficient between QFR and TTFM-related parameters was r = 0.390 (P = 0.099) and r = −0.147 (P = 0.548) for Qm and PI, respectively, in the SVG group which showed an opposite correlation trend when compared with LITA population. Additionally, a positive correlation (r = 0.344, P = 0.007) between QFR and PI was observed in the LITA group, which was more significant in the young and middle-aged groups (age < 65 years) (Figure 6).

FIGURE 5
www.frontiersin.org

Figure 5. Correlations of the preoperative QFR of the LAD and the parameters of intraoperative TTFM of the SVG to the LAD, including Qm and PI.

FIGURE 6
www.frontiersin.org

Figure 6. Correlations of the preoperative QFR of the LAD and the parameters of intraoperative TTFM of the in situ LITA graft to the LAD, including Qm and PI in different age groups.

Patency

The patency of the graft was evaluated in 108 patients (follow-up interval: 139 days). Multislice computed tomography angiography was conducted in 107 patients, and coronary angiography in 1 patient. No death was found in patients.

A distal thread sign at the LITA graft was observed in 1 patient in group A1, and early graft failure in 2 and 1 patient in groups A1 and A2, respectively. Among all the three patients in group A1, Qm and PI showed good performance with no systolic reverse flow observed. MSCTA widely patency rate was 95.5% for the LITA anastomoses, 4 anastomoses were found to be less functional (4.5%); of these, 3 (3.4%) were occluded, 1 (1.1%) presented patent with flow limited. No statistically significant difference was shown between the two groups in terms of patency rate. No patient had symptoms of angina till the latest follow-up.

For the 1 patient identified with early graft failure in group A2, intraoperative Qm was 15 ml/minute, PI was 2.5 and systolic reverse flow was observed. This patient received a stent on the left anterior descending coronary artery which was patent before surgery, and the QFR of the LAD artery was 0.83. Another stent was implanted at the coronary anastomosis 1 year after surgery.

Discussion

It has become routine to use TTFM for predicting early coronary artery bypass graft failure immediately after surgery (20). The Qm is used to describe the blood flow of the graft, but it was susceptible to many factors, including systolic blood pressure, coronary resistance, graft quality, coronary microcirculation, and anastomotic quality. PI is regarded as an important reference indicator for intraoperative assessment of graft quality. Systolic reverse flow means there is competition for blood flow between the grafts and the native vessels, indicating that blood flow directly refluxes into the graft via anastomosis (21).

Among TTFM parameters, Qm > 15 ml/min, PI < 5.0, and systolic reverse blood flow area < 30% are regarded as indicators of intraoperative graft patency. Especially, Qm and PI, the two important indicators, are most concerned during surgery (22). Mika Noda’s team showed that in LITA-LAD bypass surgery, FFR and most indicators of TTFM are correlated, with a significant negative correlation with Qm, and a significant positive correlation with PI (23). Honda et al. divided LITA-LAD bypass patients into three groups based on the FFR value of the preoperative target vessel and found obvious differences in the Qm and PI among the three groups. As the FFR value increased, the Qm decreased and PI increased subsequently (12). The consistency of QFR and FFR has been verified by many clinical studies (15, 16). Their findings coincide with the results of our study. QFR may be expected to be a more promising index than FFR for the assessment of coronary artery stenosis in the future.

In this study, coronary artery functional stenosis was mainly assessed via QFR, and the relationship between preoperative QFR value and intraoperative TTFM-related parameters, especially Qm and PI, was analyzed. We found that when undergoing in situ LITA graft to LAD: (1) Qm and PI are affected by the preoperative QFR value, and with the degree of coronary stenosis increases (that is, a lower QFR value), Qm increases, while PI decreases; (2) In the young and middle-aged population, PI is strongly affected by the preoperative QFR value; (3) The chance of flow competition increases between the native coronary artery and the graft in mild coronary artery stenosis. Moreover, in comparison with that in patients undergoing SVG-LAD bypass graft, the correlation between QFR and TTFM-related parameters such as Qm and PI showed an opposite trend. For saphenous vein grafts, due to the large diameter and the absence of a muscular layer, the pressures at both ends of the circuit are identical, with only slight phasic variations. However, in arterial grafts, the pressure at the proximal port is higher than at the distal anastomosis due to the smaller diameter and higher vasomotor tone. QFR is an assessment of the functional stenosis of the coronary artery, which reflects the hemodynamic situation of the vessel. Since the pressure of the venous grafts is significantly higher than that of the target artery, as the QFR increases, the Qm increases, and the PI decreases. Certainly, this needs to be further studied and validated in a larger sample.

However, there are still some limitations. First, this study is a retrospective study, and the possibility of bias has not been ruled out completely; Second, this study included only a small number of participants who underwent different cardiac operations at a single medical center and more patients should be included for further investigation; Third, we analyzed the correlation in the single arterial graft (in situ LITA-LAD) and SVG-LAD patients. Other graft materials such as the right internal thoracic artery, radial artery, gastroepiploic artery, and other arterial materials were not enrolled; Fourth, baseline characteristics affecting LITA such as diameter, calcification, and free flow were not recorded, a detailed assessment could be useful for identifying factors related to QFR and TTFM; Finally, in our study, postoperative follow-up was performed by MSCTA, therefore only the patency of the graft vessel and anastomosis could be observed, but the blood flow direction and competition of the graft vessel were not evaluated. Thus, a more valid evaluation system should be considered in further study to confirm the feasibility of QFR as clinical surgery guidance.

Conclusion

During in situ LITA-LAD CABG, both Qm and PI are greatly affected by QFR. In mild coronary artery stenosis assessed by QFR, the chance of flow competition between the native coronary artery and the bypass graft increased. QFR-guided CABG may be clinically feasible and safe, making it possible to be widely used for clinical surgical guidance.

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics statement

The studies involving human participants were reviewed and approved by the Ethics Committee of Beijing Anzhen Hospital, Capital Medical University. The patients/participants provided their written informed consent to participate in this study.

Author contributions

RD, CC, and YZ contributed to conception and design of the study. WL, HD, TL, YS, JZ, and KZ established the database. CC, WL, and YZ performed the statistical analysis and wrote sections of the manuscript. CC wrote the first draft of the manuscript. All authors contributed to manuscript revision, read, and approved the submitted version.

Funding

This work was supported by the Beijing Municipal Commission of Science and Technology-Capital Clinical Characteristic Applied Research and Achievement Promotion (Z171100001017059) and Beijing Municipal Health Commission-The Capital Health Research and Development of Special (Capital Development 2020-2Z-2067).

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Lindstaedt M, Spiecker M, Perings C, Lawo T, Yazar A, Holland-Letz T, et al. How good are experienced interventional cardiologists at predicting the functional significance of intermediate or equivocal left main coronary artery stenoses? Int J Cardiol. (2007) 120:254–61. doi: 10.1016/j.ijcard.2006.11.220

PubMed Abstract | CrossRef Full Text | Google Scholar

2. De Bruyne B, Fearon WF, Pijls NH, Barbato E, Tonino P, Piroth Z, et al. Fractional flow reserve-guided PCI for stable coronary artery disease. N Engl J Med. (2014) 371:1208–17. doi: 10.1056/NEJMoa1408758

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Pijls NH, van Schaardenburgh P, Manoharan G, Boersma E, Bech JW, van’t Veer M, et al. Percutaneous coronary intervention of functionally nonsignificant stenosis: 5-year follow-up of the DEFER study. J Am Coll Cardiol. (2007) 49:2105–11. doi: 10.1016/j.jacc.2007.01.087

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Neumann FJ, Sousa-Uva M, Ahlsson A, Alfonso F, Banning AP, Benedetto U, et al. 2018 ESC/EACTS guidelines on myocardial revascularization. Eur Heart J. (2019) 40:87–165. doi: 10.1093/eurheartj/ehy855

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Glineur D, Grau JB, Etienne PY, Benedetto U, Fortier JH, Papadatos S, et al. Impact of preoperative fractional flow reserve on arterial bypass graft anastomotic function: the IMPAG trial. Eur Heart J. (2019) 40:2421–8. doi: 10.1093/eurheartj/ehz329

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Toth G, De Bruyne B, Casselman F, De Vroey F, Pyxaras S, Di Serafino L, et al. Fractional flow reserve-guided versus angiography-guided coronary artery bypass graft surgery. Circulation. (2013) 128:1405–11. doi: 10.1161/CIRCULATIONAHA.113.002740

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Toth GG, De Bruyne B, Kala P, Ribichini FL, Casselman F, Ramos R, et al. Graft patency after FFR-guided versus angiography-guided coronary artery bypass grafting: the GRAFFITI trial. EuroIntervention. (2019) 15:e999–1005. doi: 10.4244/EIJ-D-19-00463

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Fournier S, Toth GG, De Bruyne B, Johnson NP, Ciccarelli G, Xaplanteris P, et al. Six-year follow-up of fractional flow reserve-guided versus angiography-guided coronary artery bypass graft surgery. Circ Cardiovasc Interv. (2018) 11:e006368. doi: 10.1161/CIRCINTERVENTIONS.117.006368

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Fournier S, Toth GG, Colaiori I, De Bruyne B, Barbato E. Long-term patency of coronary artery bypass grafts after fractional flow reserve-guided implantation. Circ Cardiovasc Interv. (2019) 12:e007712. doi: 10.1161/CIRCINTERVENTIONS.118.007712

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Spadaccio C, Glineur D, Barbato E, Di Franco A, Oldroyd KG, Biondi-Zoccai G, et al. Fractional flow reserve-based coronary artery bypass surgery: current evidence and future directions. JACC Cardiovasc Interv. (2020) 13:1086–96. doi: 10.1016/j.jcin.2019.12.017

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Botman CJ, Schonberger J, Koolen S, Penn O, Botman H, Dib N, et al. Does stenosis severity of native vessels influence bypass graft patency? A prospective fractional flow reserve-guided study. Ann Thorac Surg. (2007) 83:2093–7. doi: 10.1016/j.athoracsur.2007.01.027

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Honda K, Okamura Y, Nishimura Y, Uchita S, Yuzaki M, Kaneko M, et al. Graft flow assessment using a transit time flow meter in fractional flow reserve-guided coronary artery bypass surgery. J Thorac Cardiovasc Surg. (2015) 149:1622–8. doi: 10.1016/j.jtcvs.2015.02.050

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Tu S, Westra J, Yang J, von Birgelen C, Ferrara A, Pellicano M, et al. Diagnostic accuracy of fast computational approaches to derive fractional flow reserve from diagnostic coronary angiography: the International Multicenter FAVOR Pilot Study. JACC Cardiovasc Interv. (2016) 9:2024–35. doi: 10.1016/j.jcin.2016.07.013

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Tu S, Barbato E, Köszegi Z, Yang J, Sun Z, Holm NR, et al. Fractional flow reserve calculation from 3-dimensional quantitative coronary angiography and TIMI frame count: a fast computer model to quantify the functional significance of moderately obstructed coronary arteries. JACC Cardiovasc Interv. (2014) 7:768–77. doi: 10.1016/j.jcin.2014.03.004

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Xu B, Tu S, Qiao S, Qu X, Chen Y, Yang J, et al. Diagnostic accuracy of angiography-based quantitative flow ratio measurements for online assessment of coronary stenosis. J Am Coll Cardiol. (2017) 70:3077–87. doi: 10.1016/j.jacc.2017.10.035

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Tu S, Westra J, Adjedj J, Ding D, Liang F, Xu B, et al. Fractional flow reserve in clinical practice: from wire-based invasive measurement to image-based computation. Eur Heart J. (2020) 41:3271–9. doi: 10.1093/eurheartj/ehz918

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Xu B, Tu S, Song L, Jin Z, Yu B, Fu G, et al. Angiographic quantitative flow ratio-guided coronary intervention (FAVOR III China): a multicentre, randomised, sham-controlled trial. Lancet. (2021) 398:2149–59. doi: 10.1016/S0140-6736(21)02248-0

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Zhu Y, Zhu J, Zhang W, Chen A, Wang Z, Liu J, et al. Study of quantitative flow ratio-guided surgical coronary revascularization. J Shanghai Jiaotong Univ. (2020) 40:936–42.

Google Scholar

19. Kolh P, Wijns W, Danchin N, Di Mario C, Falk V, Folliguet T, et al. Guidelines on myocardial revascularization. Eur J Cardiothorac Surg. (2010) 38(Suppl.):S1–52. doi: 10.1016/j.ejcts.2010.08.019

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Di Giammarco G, Canosa C, Foschi M, Rabozzi R, Marinelli D, Masuyama S, et al. Intraoperative graft verification in coronary surgery: increased diagnostic accuracy adding high-resolution epicardial ultrasonography to transit-time flow measurement. Eur J Cardiothorac Surg. (2014) 45:e41–5. doi: 10.1093/ejcts/ezt580

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Leong DK, Ashok V, Nishkantha A, Shan YH, Sim EK. Transit-time flow measurement is essential in coronary artery bypass grafting. Ann Thorac Surg. (2005) 79:854–7; discussion 857–8. doi: 10.1016/j.athoracsur.2004.06.010

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Di Giammarco G, Pano M, Cirmeni S, Pelini P, Vitolla G, Di Mauro M. Predictive value of intraoperative transit-time flow measurement for short-term graft patency in coronary surgery. J Thorac Cardiovasc Surg. (2006) 132:468–74. doi: 10.1016/j.jtcvs.2006.02.014

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Noda M, Takami Y, Amano K, Sakurai Y, Akita K, Maekawa A, et al. Relation of fractional flow reserve with transit time coronary artery bypass graft flow measurement. Ann Thorac Surg. (2021) 111:134–40. doi: 10.1016/j.athoracsur.2020.04.100

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: transit-time flow measurement, coronary artery bypass grafting, fractional flow reserve (FFR), coronary artery disease, quantitative flow ratio (QFR)

Citation: Chen C, Zhao Y, Li W, Zhang K, Dang H, Liu T, Song Y, Zheng J and Dong R (2022) Relation of quantitative flow ratio with transit time coronary artery bypass graft flow measurement. Front. Cardiovasc. Med. 9:975759. doi: 10.3389/fcvm.2022.975759

Received: 22 June 2022; Accepted: 17 August 2022;
Published: 06 September 2022.

Edited by:

Antonios Karanasos, Hippokration General Hospital, Greece

Reviewed by:

Pietro Laforgia, Institut Cardiovasculaire Paris Sud, France
Yunpeng Zhu, Shanghai Jiao Tong University, China

Copyright © 2022 Chen, Zhao, Li, Zhang, Dang, Liu, Song, Zheng and Dong. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Ran Dong, drdongran@126.com

These authors have contributed equally to this work and share first authorship

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.